11789904-S1V2 FCC Report_SAR

FCC ID: C3K1782

RF Exposure Info

Download: PDF
FCCID_3701020

  SAR EVALUATION REPORT



      FCC 47 CFR § 2.1093
       IEEE Std 1528-2013

           For
PORTABLE COMPUTING DEVICE

       FCC ID: C3K1782
       Model Name: 1782


 Report Number: 11789904-S1V2
     Issue Date: 12/14/2017

         Prepared for
    Microsoft Corporation
      One Microsoft Way
Redmond, WA 95052 United States

          Prepared by
UL VERIFICATION SERVICES INC.
    47173 BENICIA STREET
  FREMONT, CA 94538, U.S.A.
      TEL: (510) 771-1000
      FAX: (510) 661-0888




     NVLAP LAB CODE 200065-0


Report No.: 11789904-S1V2                                                                       Issue Date: 12/14/2017

Revision History
 Rev.    Date             Revisions                                                        Revised By
 V1      10/30/2017       Initial Issue                                                    --
                          Section 1: Updated Highest SAR Results
                          Section 6.3: Updated Target power and Antenna naming
                          Section 9.1: Updated Max output power
                          Section 9.2: Updated Band information
 V2      12/14/2017       Section 10.1: Updated power                                      Coltyce Sanders
                          Section 10.2: Updated power
                          Section 12: Updated Table
                          Section 12.1: Updated Highest SAR values
                          Appendix A: Updated Top View Illustration




                                                    Page 2 of 27
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 11789904-S1V2                                                                                                        Issue Date: 12/14/2017

                                                                  Table of Contents

1.          Attestation of Test Results ............................................................................................................ 5

2.          Test Specification, Methods and Procedures.............................................................................. 6

3.          Facilities and Accreditation........................................................................................................... 6

4.          SAR Measurement System & Test Equipment ............................................................................ 7
     4.1.      SAR Measurement System .......................................................................................................... 7
     4.2.      SAR Scan Procedures .................................................................................................................. 8
     4.3.      Test Equipment .......................................................................................................................... 10

5.          Measurement Uncertainty ........................................................................................................... 10

6.          Device Under Test (DUT) Information ........................................................................................ 11
     6.1.      DUT Description ......................................................................................................................... 11
     6.2.      Wireless Technologies ............................................................................................................... 11
     6.3.      Maximum Output Power from Tune-up Procedure ..................................................................... 12

7.          RF Exposure Conditions (Test Configurations) ........................................................................ 15

8.          Dielectric Property Measurements & System Check ................................................................ 16
     8.1.      Dielectric Property Measurements.............................................................................................. 16
     8.2.      System Check............................................................................................................................. 18

9.          Conducted Output Power Measurements .................................................................................. 19
     9.1.      Wi-Fi 2.4GHz (DTS Band) .......................................................................................................... 19
     9.2.      Wi-Fi 5GHz (U-NII Bands) .......................................................................................................... 20
     9.3.      Bluetooth .................................................................................................................................... 20

10.         Measured and Reported (Scaled) SAR Results ......................................................................... 21
     10.1.        Wi-Fi (DTS Band) .................................................................................................................... 22
     10.2.        Wi-Fi (U-NII Band)................................................................................................................... 22
     10.3.        Bluetooth ................................................................................................................................. 22
     10.4.        Standalone SAR Test Exclusion Considerations & Estimated SAR ....................................... 23

11.         SAR Measurement Variability ..................................................................................................... 24

12.         Simultaneous Transmission SAR Analysis ............................................................................... 25
     12.1.        Sum of the SAR for WWAN & Wi-Fi & BT............................................................................... 25

Appendixes .............................................................................................................................................. 27
     11789904-S1V2 SAR_App A Setup Photos .......................................................................................... 27
     11789904-S1V1 SAR_App B System Check Plots ............................................................................... 27
     11789904-S1V1 SAR_App C Highest Test Plots .................................................................................. 27
                                                    Page 3 of 27
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 11789904-S1V2                                                                               Issue Date: 12/14/2017
  11789904-S1V1 SAR_App D Tissue Ingredients .................................................................................. 27
  11789904-S1V1 SAR_App E Probe Cal. Certificate ............................................................................. 27
  11789904-S1V1 SAR_App F Dipole Cal. Certificates ........................................................................... 27




                                                    Page 4 of 27
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 11789904-S1V2                                                                       Issue Date: 12/14/2017

1. Attestation of Test Results
Applicant Name                     MICROSOFT CORPORATION
FCC ID                             C3K1782
Model Name                         1782
                                   FCC 47 CFR § 2.1093
Applicable Standards               Published RF exposure KDB procedures
                                   IEEE Std 1528-2013
                                                                   SAR Limits (W/Kg)
Exposure Category                                                             Extremities (hands, wrists, ankles, etc.)
                                      Peak spatial-average(1g of tissue)
                                                                                           (10g of tissue)
General population /
                                                      1.6                                         4
Uncontrolled exposure
                                                    Equipment Class - Highest Reported SAR (W/kg)
RF Exposure Conditions
                                          PCE                   DTS                   NII                  DSS
Standalone                                                     0.972                 0.423                 N/A
                                           N/A
Simultaneous TX                                                1.351                 1.351                0.928
Date Tested                        6/19/2017 to 6/22/2017
Test Results                       Pass
 UL Verification Services Inc. tested the above equipment in accordance with the requirements set forth in the
 above standards. All indications of Pass/Fail in this report are opinions expressed by UL Verification Services Inc.
 based on interpretations and/or observations of test results. Measurement Uncertainties were not taken into
 account and are published for informational purposes only. The test results show that the equipment tested is
 capable of demonstrating compliance with the requirements as documented in this report.
Note: The results documented in this report apply only to the tested sample, under the conditions and modes of
operation as described herein. This document may not be altered or revised in any way unless done so by UL
Verification Services Inc. and all revisions are duly noted in the revisions section. Any alteration of this document
not carried out by UL Verification Services Inc. will constitute fraud and shall nullify the document. This report must
not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, any agency of
the Federal Government, or any agency of any government (NIST Handbook 150, Annex A). This report is written
to support regulatory compliance of the applicable standards stated above.
Approved & Released By:                                     Prepared By:




David Weaver                                                AJ Newcomer
Program Manager                                             Laboratory Engineer
UL Verification Services Inc.                               UL Verification Services Inc.




                                                    Page 5 of 27
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 11789904-S1V2                                                                      Issue Date: 12/14/2017

2. Test Specification, Methods and Procedures
The tests documented in this report were performed in accordance with FCC 47 CFR § 2.1093, IEEE STD 1528-
2013, the following FCC Published RF exposure KDB procedures:
   o 248227 D01 802.11 Wi-Fi SAR v02r02
   o 447498 D01 General RF Exposure Guidance v06
   o 447498 D03 Supplement C Cross-Reference v01
   o 616217 D04 SAR for laptop and tablets v01r02
   o 865664 D01 SAR measurement 100 MHz to 6 GHz v01r04
   o 865664 D02 RF Exposure Reporting v01r02



3. Facilities and Accreditation
The test sites and measurement facilities used to collect data are located at

             47173 Benicia Street                             47266 Benicia Street
                  SAR Lab A                                        SAR Lab 1
                  SAR Lab B                                        SAR Lab 2
                  SAR Lab C                                        SAR Lab 3
                  SAR Lab D                                        SAR Lab 4
                  SAR Lab E
                  SAR Lab F
                  SAR Lab G
                  SAR Lab H
UL Verification Services Inc. is accredited by NVLAP, Laboratory Code 200065-0.




                                                    Page 6 of 27
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 11789904-S1V2                                                                        Issue Date: 12/14/2017

4. SAR Measurement System & Test Equipment
4.1.    SAR Measurement System
The DASY5 system used for performing compliance tests consists of the following items:




•   A standard high precision 6-axis robot with controller, teach pendant and software. An arm extension for
    accommodating the data acquisition electronics (DAE).
•   An isotropic Field probe optimized and calibrated for the targeted measurement.
•   A data acquisition electronics (DAE) which performs the signal amplification, signal multiplexing, AD-
    conversion, offset measurements, mechanical surface detection, collision detection, etc. The unit is battery
    powered with standard or rechargeable batteries. The signal is optically transmitted to the EOC.
•   The Electro-optical converter (EOC) performs the conversion from optical to electrical signals for the digital
    communication to the DAE. To use optical surface detection, a special version of the EOC is required. The
    EOC signal is transmitted to the measurement server.
•   The function of the measurement server is to perform the time critical tasks such as signal filtering, control of
    the robot operation and fast movement interrupts.
•   The Light Beam used is for probe alignment. This improves the (absolute) accuracy of the probe positioning.
•   A computer running WinXP or Win7 and the DASY5 software.
•   Remote control and teach pendant as well as additional circuitry for robot safety such as warning lamps, etc.
•   The phantom, the device holder and other accessories according to the targeted measurement.




                                                    Page 7 of 27
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 11789904-S1V2                                                                      Issue Date: 12/14/2017

4.2. SAR Scan Procedures
Step 1: Power Reference Measurement
The Power Reference Measurement and Power Drift Measurements are for monitoring the power drift of the device
under test in the batch process. The minimum distance of probe sensors to surface determines the closest
measurement point to phantom surface. The minimum distance of probe sensors to surface is 2.1 mm. This
distance cannot be smaller than the distance of sensor calibration points to probe tip as defined in the probe
properties.

Step 2: Area Scan
The Area Scan is used as a fast scan in two dimensions to find the area of high field values, before doing a fine
measurement around the hot spot. The sophisticated interpolation routines implemented in DASY software can find
the maximum locations even in relatively coarse grids. When an Area Scan has measured all reachable points, it
computes the field maximal found in the scanned area, within a range of the global maximum. The range (in dB) is
specified in the standards for compliance testing. For example, a 2 dB range is required in IEEE Standard 1528
and IEC 62209 standards, whereby 3 dB is a requirement when compliance is assessed in accordance with the
ARIB standard (Japan). If only one Zoom Scan follows the Area Scan, then only the absolute maximum will be
taken as reference. For cases where multiple maximums are detected, the number of Zoom Scans has to be
increased accordingly.
Area Scan Parameters extracted from KDB 865664 D01 SAR Measurement 100 MHz to 6 GHz




                                                    Page 8 of 27
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 11789904-S1V2                                                                      Issue Date: 12/14/2017
Step 3: Zoom Scan
Zoom Scans are used to assess the peak spatial SAR values within a cubic averaging volume containing 1 g and
10 g of simulated tissue. The Zoom Scan measures points (refer to table below) within a cube whose base faces
are centered on the maxima found in a preceding area scan job within the same procedure. When the
measurement is done, the Zoom Scan evaluates the averaged SAR for 1 g and 10 g and displays these values
next to the job’s label.
Zoom Scan Parameters extracted from KDB 865664 D01 SAR Measurement 100 MHz to 6 GHz




Step 4: Power drift measurement
The Power Drift Measurement measures the field at the same location as the most recent power reference
measurement within the same procedure, and with the same settings. The Power Drift Measurement gives the field
difference in dB from the reading conducted within the last Power Reference Measurement. This allows a user to
monitor the power drift of the device under test within a batch process. The measurement procedure is the same as
Step 1.

Step 5: Z-Scan (FCC only)
The Z Scan measures points along a vertical straight line. The line runs along the Z-axis of a one-dimensional grid.
In order to get a reasonable extrapolation the extrapolated distance should not be larger than the step size in Z-
direction.




                                                    Page 9 of 27
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 11789904-S1V2                                                                        Issue Date: 12/14/2017

4.3. Test Equipment
The measuring equipment used to perform the tests documented in this report has been calibrated in accordance
with the manufacturers’ recommendations, and is traceable to recognized national standards.
 Dielectric Property Measurements
Name of Equipment                           Manufacturer           Type/Model           Serial No.      Cal. Due Date
S-Parameter Network Analyzer                   Agilent               8753ES            MY40000980        5/10/2018
Dielectric Probe kit                           SPEAG                DAK-3.5               2097           8/28/2017
Shorting block                                 SPEAG              DAK-3.5 Short       SM DAK 200 BA      11/8/2017
Thermometer                                Control Company       Traceable 4242         122529162        11/11/2017


System Check
Name of Equipment                           Manufacturer           Type/Model           Serial No.     Cal. Due Date
Synthesized Signal Generator                   Agilent              N5181A            MY50140630         5/16/2018
Power Meter                                   Keysight              N1912A            MY50001018        10/11/2017
Power Sensor                                   Agilent              N1921A            MY53260001        10/17/2017
Power Sensor                                   Agilent              N1921A             MY53070007         3/1/2018
Amplifier                                      MITEQ         AMF-4D-00400600-50-30P     1795092             N/A
Directional coupler                          Werlatone             C8060-102              2141              N/A
DC Power Supply                                 HP                   1611               215-02292           N/A


Lab Equipment
Name of Equipment                           Manufacturer           Type/Model           Serial No.     Cal. Due Date
E-Field Probe (SAR Lab 1)                     SPEAG                 EX3DV4                3751          11/17/2017
Data Acquisition Electronics (SAR Lab 1)      SPEAG                  DAE4                 1259           1/20/2018
System Validation Dipole                      SPEAG                 D2450V2                748            2/8/2018
System Validation Dipole                      SPEAG                D5GHzV2                1138           9/22/2017
Thermometer (SAR Lab 1)                       EXTECH                445703               80666           4/13/2018


Other
Name of Equipment                           Manufacturer           Type/Model           Serial No.     Cal. Due Date
Power Meter                                    Agilent              N1912A            MY55196004          7/8/2017
Power Meter                                    Agilent              N1912A            MY55196007          7/8/2017
Power Sensor                                   Agilent              N1921A            MY52260009          1/5/2018
Power Sensor                                   Agilent              N1921A            MY53020038         4/13/2018




5. Measurement Uncertainty
Per KDB 865664 D01 SAR Measurement 100 MHz to 6 GHz, when the highest measured 1-g SAR within a
frequency band is < 1.5 W/kg and the measured 10-g SAR within a frequency band is < 3.75 W/kg, the extensive
SAR measurement uncertainty analysis described in IEEE Std 1528-2013 is not required in SAR reports submitted
for equipment approval.




                                                   Page 10 of 27
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 11789904-S1V2                                                                                   Issue Date: 12/14/2017

6. Device Under Test (DUT) Information
6.1.      DUT Description
 Device Dimension              Overall (Length x Width): 223 mm x 308 mm
 Back Cover                    ☒ The Back Cover is not removable.

 Battery Options               ☒ The rechargeable battery is not user accessible.

                                         S/N                      IMEI                                Notes
 Test sample information
                                     023352671757                   N/A                      Radiated & Conducted Unit

 Hardware Version              DV
 Software Version              14.2.201.151


6.2.      Wireless Technologies
         Wireless                                                                                              Duty Cycle used for
                             Frequency bands                                Operating mode
     technologies                                                                                                    SAR testing
                                                      802.11b
                           2.4 GHz                    802.11g                                                 100%
                                                      802.11n (HT20)
                                                      802.11a
                                                      802.11n (HT20)
 Wi-Fi                                                802.11n (HT40)
                           5 GHz                                                                              100%
                                                      802.11ac (VHT20)
                                                      802.11ac (VHT40)
                                                      802.11ac (VHT80)
                           Does this device support bands 5.60 ~ 5.65 GHz? ☒ Yes ☐ No
                           Does this device support Band gap channel? ☒ Yes ☐ No
 Bluetooth                 2.4 GHz                    Version 4.0 LE                                          N/A




                                                   Page 11 of 27
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 11789904-S1V2                                                                      Issue Date: 12/14/2017

6.3.          Maximum Output Power from Tune-up Procedure
    Band                           Freq.   Max RF Output Power (dBm)
                 Mode      Ch #
   (GHz)                          (MHz)    Chain 0          Chain 1
                            1     2412       12.5             12.5
                            2     2417       12.5             12.5
                            6     2437       12.5             12.5
                802.11b    10     2457       12.5             12.5
                           11     2462       12.5             12.5
                           12     2467       10.5             10.5
                           13     2472       9.5              9.5
                            1     2412       13.5             13.5
                            2     2417       14.5             14.5
                            6     2437       14.5             14.5
   2.4
                802.11g    10     2457       14.5             14.5
   DTS
                           11     2462       13.5             13.5
                           12     2467       10.5             10.5
                           13     2472       9.5              9.5
                            1     2412       13.5             13.5
                            2     2417       14.5             14.5
                            6     2437       14.5             14.5
                802.11n    10     2457       14.5             14.5
                           11     2462       13.5             13.5
                           12     2467       10.5             10.5
                           13     2472       9.5              9.5



    Band                           Freq.   Max RF Output Power (dBm)
                 Mode      Ch #
   (GHz)                          (MHz)    Chain 0          Chain 1
                           36     5180       11.5             11.5
                           40     5200       11.5             11.5
                802.11a
                           44     5220       11.5             11.5
                           48     5240       11.5             11.5
                           36     5180       11.5             11.5

                802.11n    40     5200       11.5             11.5
                 HT20      44     5220       11.5             11.5
                           48     5240       11.5             11.5

    5.2         802.11n    38     5190       11.5             11.5
  (U-NII I)      HT40      46     5230       11.5             11.5
                           36     5180       11.5             11.5

                802.11ac   40     5200       11.5             11.5
                 VHT20     44     5220       11.5             11.5
                           48     5240       11.5             11.5

                802.11ac   38     5190       11.5             11.5
                 VHT40     46     5230       11.5             11.5

                802.11ac
                           42     5210       9.5              9.5
                 VHT80




                                                   Page 12 of 27
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 11789904-S1V2                                                                      Issue Date: 12/14/2017
     Band                         Freq.   Max RF Output Power (dBm)
                Mode      Ch #
    (GHz)                        (MHz)    Chain 0          Chain 1
                          52     5260       14.5             14.5
                          56     5280       14.5             14.5
               802.11a
                          60     5300       14.5             14.5
                          64     5320       14.5             14.5
                          52     5260       14.5             14.5

               802.11n    56     5280       14.5             14.5
                HT20      60     5300       14.5             14.5
                          64     5320       14.5             14.5

     5.3       802.11n    54     5270       12.5             12.5
  (U-NII 2A)    HT40      62     5310       12.5             12.5
                          52     5260       14.5             14.5

               802.11ac   56     5280       14.5             14.5
                VHT20     60     5300       14.5             14.5
                          64     5320       14.5             14.5

               802.11ac   54     5270       12.5             12.5
                VHT40     62     5310       12.5             12.5

               802.11ac
                          58     5290       9.5              9.5
                VHT80

                          100    5500       14.5             14.5
                          104    5520       14.5             14.5
                          108    5540       14.5             14.5
                          112    5560       14.5             14.5
                          116    5580       14.5             14.5
                          120    5600       14.5             14.5
               802.11a
                          124    5620       14.5             14.5
                          128    5640       14.5             14.5
                          132    5660       14.5             14.5
                          136    5680       14.5             14.5
                          140    5700       14.5             14.5
                          144    5720       14.5             14.5
                          100    5500       14.5             14.5
                          104    5520       14.5             14.5
     5.6                  108    5540       14.5             14.5
  (U-NII 2C)              112    5560       14.5             14.5
                          116    5580       14.5             14.5
               802.11n    120    5600       14.5             14.5
                HT20      124    5620       14.5             14.5
                          128    5640       14.5             14.5
                          132    5660       14.5             14.5
                          136    5680       14.5             14.5
                          140    5700       14.5             14.5
                          144    5720       14.5             14.5
                          102    5510       12.5             12.5
                          110    5550       12.5             12.5
               802.11n    118    5590       12.5             12.5
                HT40      126    5630       12.5             12.5
                          134    5670       12.5             12.5
                          142    5710       12.5             12.5




                                                   Page 13 of 27
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 11789904-S1V2                                                                      Issue Date: 12/14/2017
     Band                             Freq.    Max RF Output Power (dBm)
                 Mode         Ch #
    (GHz)                            (MHz)      Chain 0         Chain 1
                              100    5500           14.5          14.5
                              104    5520           14.5          14.5
                              108    5540           14.5          14.5
                              112    5560           14.5          14.5
                              116    5580           14.5          14.5

               802.11ac       120    5600           14.5          14.5
                VHT20         124    5620           14.5          14.5
                              128    5640           14.5          14.5
                              132    5660           14.5          14.5
                              136    5680           14.5          14.5
     5.6
                              140    5700           14.5          14.5
  (U-NII 2C)
                              144    5720           14.5          14.5
                              102    5510           12.5          12.5
                              110    5550           12.5          12.5

               802.11ac       118    5590           12.5          12.5
                VHT40         126    5630           12.5          12.5
                              134    5670           12.5          12.5
                              142    5710           12.5          12.5
                              106    5530           9.5           9.5
               802.11ac
                              122    5610           11.5          11.5
                VHT80
                              138    5690           11.5          11.5
                              149    5745           14.5          14.5
                              153    5765           14.5          14.5
               802.11a        157    5785           14.5          14.5
                              161    5805           14.5          14.5
                              165    5825           14.5          14.5
                              149    5745           14.5          14.5
                              153    5765           14.5          14.5
               802.11n
                              157    5785           14.5          14.5
                HT20
                              161    5805           14.5          14.5
                              165    5825           14.5          14.5
    5.8
               802.11n        151    5755           12.5          12.5
  (U-NII 3)
                HT40          159    5795           12.5          12.5
                              149    5745           14.5          14.5
                              153    5765           14.5          14.5
               802.11ac
                              157    5785           14.5          14.5
                VHT20
                              161    5805           14.5          14.5
                              165    5825           14.5          14.5

               802.11ac       151    5755           12.5          12.5
                VHT40         159    5795           12.5          12.5

               802.11ac
                              155    5775           11.5          11.5
                VHT80



                                   Max. RF Output Power
 RF Air interface           Mode          (dBm)
                                         Chain 1
                          GFSK,EDR          4.5
     Bluetooth
                             LE               4.5




                                                   Page 14 of 27
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 11789904-S1V2                                                                      Issue Date: 12/14/2017

7. RF Exposure Conditions (Test Configurations)
Refer to Appendix A for the specific details of the antenna-to-antenna and antenna-to-edge(s) distances.
     Wireless        RF Exposure        DUT-to-User          Test            Antenna-to-         SAR
   technologies       Conditions         Separation         Position        edge/surface       Required
      WLAN
                      Standalone           0 mm               Rear             N/A                Yes
      Chain 0
     WLAN/BT
                      Standalone           0 mm               Rear             N/A                Yes
      Chain 1




                                                   Page 15 of 27
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 11789904-S1V2                                                                         Issue Date: 12/14/2017

8. Dielectric Property Measurements & System Check
8.1.    Dielectric Property Measurements
The temperature of the tissue-equivalent medium used during measurement must also be within 18°C to 25°C and
within ± 2°C of the temperature when the tissue parameters are characterized.
The dielectric parameters must be measured before the tissue-equivalent medium is used in a series of SAR
measurements. The parameters should be re-measured after each 3 – 4 days of use; or earlier if the dielectric
parameters can become out of tolerance; for example, when the parameters are marginal at the beginning of the
measurement series.
Tissue dielectric parameters were measured at the low, middle and high frequency of each operating frequency
range of the test device.
The dielectric constant (εr) and conductivity (σ) of typical tissue-equivalent media recipes are expected to
be within ± 5% of the required target values; but for SAR measurement systems that have implemented the SAR
error compensation algorithms documented in IEEE Std 1528-2013, to automatically compensate the measured
SAR results for deviations between the measured and required tissue dielectric parameters, the tolerance for εr and
σ may be relaxed to ± 10%. This is limited to frequencies ≤ 3 GHz.

Tissue Dielectric Parameters
FCC KDB 865664 D01 SAR Measurement 100 MHz to 6 GHz
                                                Head                                       Body
    Target Frequency (MHz)
                                      εr                  σ (S/m)                εr                   σ (S/m)
             150                     52.3                  0.76                 61.9                   0.80
             300                     45.3                  0.87                 58.2                   0.92
             450                     43.5                  0.87                 56.7                   0.94
             835                     41.5                  0.90                 55.2                   0.97
             900                     41.5                  0.97                 55.0                   1.05
             915                     41.5                  0.98                 55.0                   1.06
            1450                     40.5                  1.20                 54.0                   1.30
            1610                     40.3                  1.29                 53.8                   1.40
         1800 – 2000                 40.0                  1.40                 53.3                   1.52
            2450                     39.2                  1.80                 52.7                   1.95
            3000                     38.5                  2.40                 52.0                   2.73
            5000                     36.2                  4.45                 49.3                   5.07
            5100                     36.1                  4.55                 49.1                   5.18
            5200                     36.0                  4.66                 49.0                   5.30
            5300                     35.9                  4.76                 48.9                   5.42
            5400                     35.8                  4.86                 48.7                   5.53
            5500                     35.6                  4.96                 48.6                   5.65
            5600                     35.5                  5.07                 48.5                   5.77
            5700                     35.4                  5.17                 48.3                   5.88
            5800                     35.3                  5.27                 48.2                   6.00


IEEE Std 1528-2013
Refer to Table 3 within the IEEE Std 1528-2013




                                                   Page 16 of 27
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 11789904-S1V2                                                                               Issue Date: 12/14/2017
Dielectric Property Measurements Results:
                                                            Relative Permittivity (єr)                 Conductivity (σ)
   SAR                  Band      Tissue   Frequency
              Date                                                                  Delta                                 Delta
   Lab                  (MHz)      Type      (MHz)     Measured      Target                 Measured        Target
                                                                                     (%)                                   (%)
                                              2450      52.39         52.70         -0.59     2.02           1.95         3.64
     1      6/19/2017   2450       Body       2400      52.41         52.77         -0.69     1.98           1.90         4.11
                                              2480      52.30         52.66         -0.69     2.05           1.99         2.90
                                              5200      51.18         49.02          4.41     5.31           5.29         0.29
     1      6/19/2017   5200       Body       5150      51.00         49.09          3.90     5.35           5.24         2.11
                                              5350      50.65         48.82          3.76     5.54           5.47         1.25
                                              5600      50.23         48.48          3.61     5.91           5.76         2.60
     1      6/19/2017   5600       Body       5500      50.66         48.61          4.21     5.73           5.64         1.55
                                              5725      49.90         48.31          3.29     6.06           5.91         2.61
                                              5800      49.99         48.20          3.71     6.20           6.00         3.33
     1      6/19/2017   5800       Body       5700      50.27         48.34          3.99     6.03           5.88         2.52
                                              5850      49.59         48.20          2.88     6.27           6.00         4.48




                                                   Page 17 of 27
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 11789904-S1V2                                                                                                                          Issue Date: 12/14/2017

8.2.         System Check
SAR system verification is required to confirm measurement accuracy, according to the tissue dielectric media,
probe calibration points and other system operating parameters required for measuring the SAR of a test device.
The system verification must be performed for each frequency band and within the valid range of each probe
calibration point required for testing the device. The same SAR probe(s) and tissue-equivalent media combinations
used with each specific SAR system for system verification must be used for device testing. When multiple probe
calibration points are required to cover substantially large transmission bands, independent system verifications are
required for each probe calibration point. A system verification must be performed before each series of SAR
measurements using the same probe calibration point and tissue-equivalent medium. Additional system verification
should be considered according to the conditions of the tissue-equivalent medium and measured tissue dielectric
parameters, typically every three to four days when the liquid parameters are re-measured or sooner when
marginal liquid parameters are used at the beginning of a series of measurements.

System Performance Check Measurement Conditions:
•        The measurements were performed in the flat section of the TWIN SAM or ELI phantom, shell thickness: 2.0
         ±0.2 mm (bottom plate) filled with Body or Head simulating liquid of the following parameters.
•        The depth of tissue-equivalent liquid in a phantom must be ≥ 15.0 cm for SAR measurements ≤ 3 GHz and ≥
         10.0 cm for measurements > 3 GHz.
•        The DASY system with an E-Field Probe was used for the measurements.
•        The dipole was mounted on the small tripod so that the dipole feed point was positioned below the center
         marking of the flat phantom section and the dipole was oriented parallel to the body axis (the long side of the
         phantom). The standard measuring distance was 10 mm (above 1 GHz) and 15 mm (below 1 GHz) from dipole
         center to the simulating liquid surface.
•        The coarse grid with a grid spacing of 15 mm was aligned with the dipole.
         For 5 GHz band - The coarse grid with a grid spacing of 10 mm was aligned with the dipole.
•        Special 7x7x7 (below 3 GHz) and/or 8x8x7 (above 3 GHz) fine cube was chosen for the cube.
•        Distance between probe sensors and phantom surface was set to 3 mm.
         For 5 GHz band - Distance between probe sensors and phantom surface was set to 2.5 mm
•        The dipole input power (forward power) was 100 mW.
•        The results are normalized to 1 W input power.


System Check Results
The 1-g and 10-g SAR measured with a reference dipole, using the required tissue-equivalent medium at the test
frequency, must be within 10% of the manufacturer calibrated dipole SAR target.

                                                                                       Measured Results for 1g SAR                      Measured Results for 10g SAR
    SAR                 Tissue          Dipole Type             Dipole                                                                                                         Plot
              Date
    Lab                  Type            _Serial #           Cal. Due Data   Zoom Scan     Normalize     Target       Delta   Zoom Scan     Normalize     Target       Delta   No.
                                                                             to 100 mW      to 1 W     (Ref. Value)   ±10 %   to 100 mW      to 1 W     (Ref. Value)   ±10 %

     1      6/19/2017   Body         D2450V2 SN:748            2/8/2018        5.490         54.90        51.30       7.02      2.510         25.10        23.90       5.02    1,2

     1      6/19/2017   Body     D5GHzV2 SN:1138 (5.2 GHz)    9/22/2017        7.730         77.30        74.20       4.18      2.170         21.70        20.90       3.83

     1      6/19/2017   Body     D5GHzV2 SN:1138 (5.6 GHz)    9/22/2017        8.230         82.30        78.80       4.44      2.270         22.70        22.00       3.18    3,4

     1      6/19/2017   Body     D5GHzV2 SN:1138 (5.8 GHz)    9/22/2017        7.540         75.40        75.70       -0.40     2.080         20.80        21.10       -1.42




                                                   Page 18 of 27
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 11789904-S1V2                                                                                      Issue Date: 12/14/2017

9. Conducted Output Power Measurements
9.1.         Wi-Fi 2.4GHz (DTS Band)
Measured Results
      Band                                     Freq.     Meas. Avg Pwr (dBm)       Max Output Power (dBm)   SAR Test
                Mode     Data Rate   Ch #
     (GHz)                                    (MHz)      Chain 0      Chain 1       Chain 0      Chain 1    (Yes/No)
                                      1       2412        11.4          10.7
                                      2       2417        11.4          12.0
               802.11b    1 Mbps      6       2437        11.3          11.8         12.5         12.5        Yes
                                     10       2457        11.7          12.1
                                     11       2462        11.2          10.7
                                      1       2412        12.3          11.8         13.5         13.5
     2.4
                                      2       2417        12.7          12.9
     DTS
               802.11g    6 Mbps      6       2437        13.4          12.7                                  Yes
                                                                                     14.5         14.5
                                     10       2457        12.5          12.7
                                     11       2462        12.6          11.4
                                      1       2412                                   13.5         13.5
               802.11n
                         6.5 Mbps     6       2437     Not Required Not Required                              No
               (HT20)                                                                14.5         14.5
                                     11       2462


Note(s):
1.    SAR is not required for OFDM Modes when the highest reported SAR for DSSS is adjusted by the ratio of OFDM to DSSS
      specified maximum output power and the adjusted SAR is ≤ 1.2 W/kg
2.    For “Not required”, SAR Test reduction was applied from KDB 248227 §5.3.4 b).
3.    Additionally, SAR is not required for Channels 12 and 13 because the tune-up limit and the measured output power for
      these two channels are no greater than those for the default test channels.




                                                   Page 19 of 27
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 11789904-S1V2                                                                                           Issue Date: 12/14/2017

9.2.             Wi-Fi 5GHz (U-NII Bands)
Measured Results
      Band                                       Freq.      Meas. Avg Pwr (dBm)        Max Output Power (dBm)   SAR Test
                   Mode      Data Rate   Ch #
      (GHz)                                     (MHz)      Chain 0        Chain 1      Chain 0       Chain 1    (Yes/No)
                                         52     5260         12.9           13.4
                  802.11a     6 Mbps     60     5300         13.0           13.5        14.5           14.5       Yes
                                         64     5320         13.0           13.0
                                         52     5260
                  802.11n
                             6.5 Mbps    60     5300                                    14.5           14.5       No
                  (HT20)
                                         64     5320
                  802.11n                54     5270
    5.3                      13.5 Mbps                                                  12.5           12.5       No
                  (HT40)                 62     5310
 (U-NII 2A)
                                         52     5260
                  802.11ac                               Not Required   Not Required
                             6.5 Mbps    60     5300                                    14.5           14.5       No
                  (VHT20)
                                         64     5320
                  802.11ac               54     5270
                             13.5 Mbps                                                  12.5           12.5       No
                  (VHT40)                62     5310
                  802.11ac
                             29.3 Mbps   58     5290                                     9.5           9.5        No
                  (VHT80)
                                         100    5500         12.6           12.8
                  802.11a     6 Mbps     116    5580         12.7           12.7        14.5           14.5       Yes
                                         140    5700         12.5           12.6
                                         100    5500
                  802.11n
                             6.5 Mbps    116    5580                                    14.5           14.5       No
                  (HT20)
                                         140    5700
                                         102    5510
                  802.11n
                             13.5 Mbps   110    5550                                    12.5           12.5       No
                  (HT40)
    5.6                                  134    5670
 (U-NII 2C)                              100    5500
                  802.11ac
                             6.5 Mbps    116    5580     Not Required   Not Required    14.5           14.5       No
                  (VHT20)
                                         140    5700
                                         102    5510
                  802.11ac
                             13.5 Mbps   110    5550                                    12.5           12.5       No
                  (VHT40)
                                         134    5670
                                         106    5530                                     9.5           9.5
                  802.11ac
                             29.3 Mbps   122    5610                                                              No
                  (VHT80)                                                               11.5           11.5
                                         138    5690
                                         149    5745         12.2           12.7
                  802.11a     6 Mbps     157    5785         12.4           13.1        14.5           14.5       Yes
                                         165    5825         12.5           13.1
                                         149    5745
                  802.11n
                             6.5 Mbps    157    5785                                    14.5           14.5       No
                  (HT20)
                                         165    5825
                  802.11n                151    5755
       5.8                   13.5 Mbps                                                  12.5           12.5       No
     (U-NII 3)    (HT40)                 159    5795
                                         149    5745     Not Required   Not Required
                  802.11ac
                             6.5 Mbps    157    5785                                    14.5           14.5       No
                  (VHT20)
                                         165    5825
                  802.11ac               151    5755
                             13.5 Mbps                                                  12.5           12.5       No
                  (VHT40)                159    5795
                  802.11ac
                             29.3 Mbps   155    5775                                    11.5           11.5       No
                  (VHT80)


Note(s):
1.      For “Not required”, SAR Test reduction was applied per KDB 248227.
2.      When the specified maximum output power is the same for both UNII band I and UNII band 2A, begin SAR measurement in
        UNII band 2A; and if the highest reported SAR for UNII band 2A is
             o    ≤ 1.2 W/kg, SAR is not required for UNII band I
             o    > 1.2 W/kg, both bands should be tested independently for SAR.

9.3.             Bluetooth
Maximum tune-up tolerance limit is 4.5 dBm. This power level qualifies for exclusion of SAR testing. Refer to §10.5
for Standalone SAR Test Exclusion Considerations & Estimated SAR.




                                                   Page 20 of 27
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 11789904-S1V2                                                                                    Issue Date: 12/14/2017

10.      Measured and Reported (Scaled) SAR Results
SAR Test Reduction criteria are as follows:

KDB 447498 D01 General RF Exposure Guidance:
Testing of other required channels within the operating mode of a frequency band is not required when the reported 1-g or 10-g
SAR for the mid-band or highest output power channel is:
•   ≤ 0.8 W/kg or 2.0 W/kg, for 1-g or 10-g respectively, when the transmission band is ≤ 100 MHz
•   ≤ 0.6 W/kg or 1.5 W/kg, for 1-g or 10-g respectively, when the transmission band is between 100 MHz and 200 MHz
•   ≤ 0.4 W/kg or 1.0 W/kg, for 1-g or 10-g respectively, when the transmission band is ≥ 200 MHz

KDB 248227 D01 SAR meas for 802.11:
SAR test reduction for 802.11 Wi-Fi transmission mode configurations are considered separately for DSSS and OFDM. An initial
test position is determined to reduce the number of tests required for certain exposure configurations with multiple test positions.
An initial test configuration is determined for each frequency band and aggregated band according to maximum output power,
channel bandwidth, wireless mode configurations and other operating parameters to streamline the measurement requirements.
For 2.4 GHz DSSS, either the initial test position or DSSS procedure is applied to reduce the number of SAR tests; these are
mutually exclusive. For OFDM, an initial test position is only applicable to next to the ear, UMPC mini-tablet and hotspot mode
configurations, which is tested using the initial test configuration to facilitate test reduction. For other exposure conditions with a
fixed test position, SAR test reduction is determined using only the initial test configuration.
     The multiple test positions require SAR measurements in head, hotspot mode or UMPC mini-tablet configurations may be
reduced according to the highest reported SAR determined using the initial test position(s) by applying the DSSS or OFDM SAR
measurement procedures in the required wireless mode test configuration(s). The initial test position(s) is measured using the
highest measured maximum output power channel in the required wireless mode test configuration(s). When the reported SAR
for the initial test position is:

    •    ≤ 0.4 W/kg, further SAR measurement is not required for the other test positions in that exposure configuration and
         wireless mode combination within the frequency band or aggregated band. DSSS and OFDM configurations are
         considered separately according to the required SAR procedures.
    •    > 0.4 W/kg, SAR is repeated using the same wireless mode test configuration tested in the initial test position to
         measure the subsequent next closet/smallest test separation distance and maximum coupling test position, on the
         highest maximum output power channel, until the reported SAR is ≤ 0.8 W/kg or all required test positions are tested.
         o For subsequent test positions with equivalent test separation distance or when exposure is dominated by coupling
              conditions, the position for maximum coupling condition should be tested.
         o When it is unclear, all equivalent conditions must be tested.
    •    For all positions/configurations tested using the initial test position and subsequent test positions, when the reported
         SAR is > 0.8 W/kg, measure the SAR for these positions/configurations on the subsequent next highest measured
         output power channel(s) until the reported SAR is ≤ 1.2 W/kg or all required test channels are considered.
         o The additional power measurements required for this step should be limited to those necessary for identifying
              subsequent highest output power channels to apply the test reduction.
    •    When the specified maximum output power is the same for both UNII 1 and UNII 2A, begin SAR measurements in UNII
         2A with the channel with the highest measured output power. If the reported SAR for UNII 2A is ≤ 1.2 W/kg, SAR is not
         required for UNII 1; otherwise treat the remaining bands separately and test them independently for SAR.
    •    When the specified maximum output power is different between UNII 1 and UNII 2A, begin SAR with the band that has
         the higher specified maximum output. If the highest reported SAR for the band with the highest specified power is ≤
         1.2 W/kg, testing for the band with the lower specified output power is not required; otherwise test the remaining bands
         independently for SAR.

     To determine the initial test position, Area Scans were performed to determine the position with the Maximum Value of SAR
(measured). The position that produced the highest Maximum Value of SAR is considered the worst case position; thus used as
the initial test position.




                                                   Page 21 of 27
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 11789904-S1V2                                                                                                                                         Issue Date: 12/14/2017

10.1. Wi-Fi (DTS Band)
                                                                                                      Power (dBm)                                          1-g SAR (W/kg)
RF Exposure                        Dist.                                                Chain 0                      Chain 1                    Chain 0                      Chain 1           Plot
               Mode     Antenna            Test Position   Ch #.   Freq. (MHz)
 Conditions                       (mm)                                           Tune-up                      Tune-up                                                                          No.
                                                                                                Meas.                        Meas.      Meas.         Scaled         Meas.         Scaled
                                                                                  Limit                        Limit
                                                            2        2417         12.5          11.4           12.5          12.0       0.587             0.756      0.403             0.452
              802.11b   2 Tx
Standalone                          0          Rear         6        2437         12.5              11.3       12.5              11.8   0.500             0.659      0.374             0.439
              1 Mbps    MIMO
                                                            10       2457         12.5              11.7       12.5              12.1   0.733             0.881      0.424             0.465
                                                            2        2417         14.5              12.7       14.5              12.9   0.615             0.931      0.404             0.584
              802.11g   2 Tx
Standalone                          0          Rear         6        2437         14.5              13.4       14.5              12.7   0.454             0.585      0.381             0.577
              6 Mbps    MIMO
                                                            10       2457         14.5              12.5       14.5              12.7   0.613             0.972      0.451             0.683    1




10.2. Wi-Fi (U-NII Band)
                                                                                                      Pow er (dBm)                                         1-g SAR (W/kg)
   RF
                                   Dist.      Test                                        Chain 0                      Chain 1                  Chain 0                      Chain 1           Plot
Exposure       Mode     Antenna                            Ch #.   Freq. (MHz)
                                  (mm)       Position                            Tune-up                      Tune-up                                                                          No.
Conditions                                                                                      Meas.                        Meas.      Meas.         Scaled         Meas.         Scaled
                                                                                   Limit                        Limit
              5.3 GHz                                       52        5260         14.5             12.9        14.5             13.4   0.292             0.423      0.295             0.379    2
                         2 Tx
Standalone    802.11a               0          Rear         60        5300         14.5             13.0        14.5             13.5   0.284             0.400      0.259             0.330
                         MIMO
              6 Mbps                                        64        5320         14.5             13.0        14.5             13.0   0.237             0.336      0.209             0.293



                                                                                                      Pow er (dBm)                                         1-g SAR (W/kg)
   RF
                                   Dist.      Test                                        Chain 0                      Chain 1                  Chain 0                      Chain 1           Plot
Exposure       Mode     Antenna                            Ch #.   Freq. (MHz)
                                  (mm)       Position                            Tune-up                      Tune-up                                                                          No.
Conditions                                                                                      Meas.                        Meas.      Meas.         Scaled         Meas.         Scaled
                                                                                   Limit                        Limit
              5.6 GHz                                      100        5500         14.5             12.6        14.5             12.8   0.159             0.246      0.184             0.272
                         2 Tx
Standalone    802.11a               0          Rear        116        5580         14.5             12.7        14.5             12.7   0.131             0.197      0.117             0.176
                         MIMO
              6 Mbps                                       140        5700         14.5             12.5        14.5             12.6   0.253             0.404      0.193             0.302    3



                                                                                                      Power (dBm)                                          1-g SAR (W/kg)
RF Exposure                        Dist.                                                Chain 0                      Chain 1                    Chain 0                      Chain 1           Plot
               Mode     Antenna            Test Position   Ch #.   Freq. (MHz)
 Conditions                       (mm)                                           Tune-up                      Tune-up                                                                          No.
                                                                                                Meas.                        Meas.      Meas.         Scaled         Meas.         Scaled
                                                                                  Limit                        Limit
              5.8 GHz                                      149       5745         14.5          12.2           14.5          12.7       0.243             0.411      0.199             0.299    4
                        2 Tx
Standalone    802.11a               0          Rear        157       5785         14.5              12.4       14.5              13.1   0.125             0.201      0.112             0.156
                        MIMO
              6 Mbps                                       165       5825         14.5              12.5       14.5              13.1   0.126             0.200      0.081             0.113


10.3.          Bluetooth
Maximum tune-up tolerance limit is 4.5 dBm. This power level qualifies for exclusion of SAR testing. Refer to §10.5
for Standalone SAR Test Exclusion Considerations & Estimated SAR.




                                                   Page 22 of 27
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 11789904-S1V2                                                                                         Issue Date: 12/14/2017

10.4.       Standalone SAR Test Exclusion Considerations & Estimated SAR
The 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances
≤ 50 mm are determined by:
[(max. power of channel, including tune-up tolerance, mW) / (min. test separation distance, mm)]·[√f(GHz)] ≤ 3.0, for 1-g SAR
and ≤ 7.5 for 10-g extremity SAR, where
    •    f(GHz) is the RF channel transmit frequency in GHz
    •    Power and distance are rounded to the nearest mW and mm before calculation
    •    The result is rounded to one decimal place for comparison
The test exclusions are applicable only when the minimum test separation distance is ≤ 50 mm and for
transmission frequencies between 100 MHz and 6 GHz. When the minimum test separation distance is < 5 mm, a
distance of 5 mm is applied to determine SAR test exclusion.

When the standalone SAR test exclusion is applied to an antenna that transmits simultaneously with other
antennas, the standalone SAR must be estimated according to following to determine simultaneous transmission
SAR test exclusion:
    •    (max. power of channel, including tune-up tolerance, mW) / (min. test separation distance, mm)]·[√f(GHz)/x] W/kg for test
         separation distances ≤ 50 mm;
                  where x = 7.5 for 1-g SAR, and x = 18.75 for 10-g SAR.
    •    0.4 W/kg for 1-g SAR and 1.0 W/kg for 10-g SAR, when the test separation distances is > 50 mm.


                                                     Max. tune-up tolerance Power        Min. test    SAR test
                   RF Exposure       Frequency                                                                       Estimated
RF Air interface                                                                        separation    exclusion
                    Conditions         (GHz)                                                                      1-g SAR (W/kg)
                                                        (dBm)             (mW)        distance (mm)    Result*

   Bluetooth       Standalone          2.480              4.5               3                0           0.9          0.126

Conclusion:
*: The computed value is ≤ 3; therefore, this qualifies for Standalone SAR test exclusion.




                                                   Page 23 of 27
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 11789904-S1V2                                                                          Issue Date: 12/14/2017

11.       SAR Measurement Variability
In accordance with published RF Exposure KDB 865664 D01 SAR measurement 100 MHz to 6 GHz. These
additional measurements are repeated after the completion of all measurements requiring the same head or body
tissue-equivalent medium in a frequency band. The test device should be returned to ambient conditions (normal
room temperature) with the battery fully charged before it is re-mounted on the device holder for the repeated
measurement(s) to minimize any unexpected variations in the repeated results.

1) Repeated measurement is not required when the original highest measured SAR is <0.8 or 2 W/kg (1-g or 10-g
   respectively); steps 2) through 4) do not apply.
2) When the original highest measured SAR is ≥ 0.8 or 2 W/kg (1-g or 10-g respectively), repeat that
   measurement once.
3) Perform a second repeated measurement only if the ratio of largest to smallest SAR for the original and first
   repeated measurements is > 1.20 or when the original or repeated measurement is ≥ 1.45 or 3.6 W/kg (~ 10%
   from the 1-g or 10-g respective SAR limit).
4) Perform a third repeated measurement only if the original, first, or second repeated measurement is ≥ 1.5 or
   3.75 W/kg (1-g or 10-g respectively) and the ratio of largest to smallest SAR for the original, first and second
   repeated measurements is > 1.20.

 Frequency                                                                 Repeated     Highest
    Band        Air Interface     RF Exposure Conditions   Test Position     SAR       Measured
   (MHz)                                                                   (Yes/No)   SAR (W/kg)

   2400      Wi-Fi 802.11b/g/n         Standalone              Rear          No         0.733
   5300      Wi-Fi 802.11a/n/ac        Standalone              Rear          No         0.295
   5500      Wi-Fi 802.11a/n/ac        Standalone              Rear          No         0.253
   5800      Wi-Fi 802.11a/n/ac        Standalone              Rear          No         0.243


Note(s):
Repeated Measurement is not required because measured SAR is < 0.8 W/kg.




                                                   Page 24 of 27
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 11789904-S1V2                                                                                                                                                       Issue Date: 12/14/2017

12.            Simultaneous Transmission SAR Analysis
Simultaneous Transmission Condition
                                                                                 Capable Transmit Configurations
    RF Exposure Condition                                Item
                                                                                Chain 0                                 Chain 1
                                                          1                      DTS                    +                 DTS
                                                          2                      U-NII                  +                U-NII
                                                          3                      DTS                    +                U-NII
              Standalone
                                                          4                      U-NII                  +                 DTS
                                                          5                      U-NII                  +                  BT
                                                          6                      U-NII                  +               U-NII/BT
Notes:
      1. Bluetooth Radio is only supported on Chain 1.
      2.  DTS Radio cannot transmit simultaneously with Bluetooth Radio.
      3.  U-NII Radio can transmit simultaneously with Bluetooth Radio.

12.1. Sum of the SAR for WWAN & Wi-Fi & BT
                                                  Standalone SAR (W/kg)                                                            ∑ 1-g SAR (W/kg)
    RF
 Exposure     Test Position              DTS                     U-NII              BT      DTS + DTS   U-NII + U-NII   DTS + U-NII    DTS + U-NII       U-NII + BT   U-NII + BT
 conditions                    Chain 0         Chain 1    Chain 0     Chain 1     Chain 1
                                                                                             ①+②            ③+④           ①+④            ②+③                ③+⑤       ③+④+⑤
                                 ①               ②          ③           ④           ⑤
Standalone        Rear          0.972           0.683      0.423       0.379       0.126      1.655         0.802          1.351          1.106             0.549       0.928




SAR to Peak Location Separation Ratio (SPLSR)
                         Standalone SAR (W/kg)
                                                                                                      Calculated                       Volume
                                  DTS                                         ∑ 1-g SAR                                 SPLSR
 Test Position                  ①                     ②                                                distance                         Scan          Figure
                              Chain 0               Chain 1                     (W/kg)                                  (≤ 0.04)
                                                                                                         (mm)                         (Yes/ No)
       Rear                   0.972                  0.683                +              1.655          318.0            0.01             No            1


Conclusion:
Simultaneous transmission SAR measurement (Volume Scan) is not required because the SPLSR is ≤ 0.04.




                                                   Page 25 of 27
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 11789904-S1V2                                                                                      Issue Date: 12/14/2017
                                                            Figure (1)


                                                                               2.4G Chain 0




                                                                           d




                                                                               2.4G Chain 1


                                         Peak SAR         X            Y             Z        d: Calculated distance
                         Mode     ①                                                                   (mm)
                                            W/kg          m            m             m
                                  ②
                 Chain 0 (2.4G)             1.09         0.03        0.154         -0.181
                                                                                              ①+②           318.0
                 Chain 1 (2.4G)            0.801        0.033        -0.164        -0.181
                 The Peak Location Separation Distance is computed by using the
                 SQRT((X1-X2)^2+(Y1-Y2)^2+(Z1-Z2)^2)




                                                   Page 26 of 27
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 11789904-S1V2                                                                      Issue Date: 12/14/2017

Appendixes
Refer to separated files for the following appendixes.

11789904-S1V2 SAR_App A Setup Photos

11789904-S1V1 SAR_App B System Check Plots

11789904-S1V1 SAR_App C Highest Test Plots

11789904-S1V1 SAR_App D Tissue Ingredients

11789904-S1V1 SAR_App E Probe Cal. Certificate

11789904-S1V1 SAR_App F Dipole Cal. Certificates



                                                END OF REPORT




                                                   Page 27 of 27
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.



Document Created: 2017-12-18 08:40:43
Document Modified: 2017-12-18 08:40:43

© 2024 FCC.report