1756-FCCIC-RF Exposure Evaluation Report

FCC ID: C3K1756

RF Exposure Info

Download: PDF
FCCID_3166248

RF Exposure Evaluation Report
                   For

         MODEL NO. 1756
         FCC ID: C3K1756
         IC ID: 3048A-1756

 Test Report No. R-TR378-FCCIC-RFE-2
        Issue Date: 26 Sep, 2016

     FCC CFR47 Part 2.1093
  ISED Canada RSS-102: Issue 5


             Prepared by
      Microsoft EMC Laboratory
         17760 NE 67th Ct,
     Redmond WA, 98052, U.S.A.
            425-421-9799
       sajose@microsoft.com




          TESTING CERT #3472.01




                                       Report V2.0


1 Record of Revisions
 Revision   Date         Section Page(s)    Summary of Changes          Author/Revised
                                                                        By:
 1.0        08/04/2016   All     All        Version 1.0                 Daniel Salinas
 2.0        09/26/2016   All     All        Updated Report file name.   Daniel Salinas




Report#: R-TR378-FCCIC-RFE-2       Issued: 26 Sep, 2016                     Page 2 of 10
                                 Microsoft EMC Laboratory


Table of Contents
1     Record of Revisions ............................................................................................................... 2
2     Product Description ............................................................................................................... 5
3     Facilities and Accreditations .................................................................................................. 6
    3.1     Test Facility .................................................................................................................... 6
    3.2     Accreditations ................................................................................................................. 6
4     Average Conducted Output Power Measurements ............................................................... 7
    4.1     Test Configuration .......................................................................................................... 7
    4.2     Test Method- Average Power ......................................................................................... 7
    4.3     Test Equipment List ........................................................................................................ 7
    4.4     Test Results .................................................................................................................... 8
5     SAR Test Exclusion ............................................................................................................... 9
    5.1     FCC ................................................................................................................................ 9
    5.2     ISED ............................................................................................................................... 9




Report#: R-TR378-FCCIC-RFE-2                           Issued: 26 Sep, 2016                                                     Page 3 of 10
                                                    Microsoft EMC Laboratory


                      Test Report Attestation
                                          Microsoft Corporation
                                               Model: 1756
                                            FCC ID: C3K 1756
                                            IC ID: 3048A-1756


Applicable Standards
         Specification                                                      Test Result
 FCC CFR47 Part 2.1093                                                Complies
 ISED Canada RSS-102 Issue 5



Microsoft EMC Laboratory attests that the product model identified in this report has been tested to and
meets the requirements identified in the above standards. The test results in this report solely pertains to
the specific sample tested, under the conditions and operating modes as provided by the customer.

This report shall not be used to claim product certification, approval, or endorsement by A2LA or any
agency of any Government. Reproduction, duplication or publication of extracts from this test report
requires prior written approval of Microsoft EMC Laboratory.
This report replaces the previously issued report #R-TR378-FCCIC-MPE-1 issued by Microsoft EMC Labs
on 8/4/2016.




Written by: Daniel Salinas                             Reviewed/ Approved by: Sajay Jose
Radio Test Lead                                        EMC/RF Compliance Lab Manager




Report#: R-TR378-FCCIC-RFE-2             Issued: 26 Sep, 2016                                   Page 4 of 10
                                       Microsoft EMC Laboratory


2 Product Description
 Company Name:            Microsoft Corporation

 Address:                 One Microsoft Way

 City, State, Zip:        Redmond, WA 98052-6399

 Customer Contact:        Chaitrali Limaye
 Functional Description of
                           Wireless Input Accessory Device with BTLE Radio
 the EUT:
 Model:                   1756

 FCC ID:                  C3K1756

 IC ID:                   3048A-1756

 Radio Description:       Bluetooth LE
 Frequency Range of
                          2.4 GHz- 2.4835 GHz
 Operation:
                          Internal Antenna
 Antenna Info:
                          Gain: +1.73 dBi (@2.4 GHz)
 EUT Classification:      DTS

 Equipment Design State: Production Equivalent

 Equipment Condition:     Good

 RF Exposure Conditions: Extremity Exposure, Body Exposure




Report#: R-TR378-FCCIC-RFE-2       Issued: 26 Sep, 2016                      Page 5 of 10
                                 Microsoft EMC Laboratory


3 Facilities and Accreditations
3.1 Test Facility
 All facilities used to collect the test data are located at Microsoft EMC Laboratory,
 17760 NE 67th Ct, Redmond WA, 98052, USA

3.2 Accreditations
 The lab is established and follows procedures as outlined in IEC/ISO 17025 and A2LA
 accreditation requirements.
 A2LA Accredited Testing Certificate Number: 3472.01




Report#: R-TR378-FCCIC-RFE-2          Issued: 26 Sep, 2016                               Page 6 of 10
                                   Microsoft EMC Laboratory


4 Average Conducted Output Power Measurements
4.1 Test Configuration
The EUT is pre-programmed to transmit continuously in BTLE mode at low/mid/high channels of
the frequency band. The actual test mode is identified by the LED on the EUT.

Channel 0: Slow White LED blink.
Channel 19: Fast white LED blink.
Channel 39: Solid white LED blink.


4.2 Test Method- Average Power
(According to KDB 558074 Section 9.2.3.1)

Antenna port conducted measurements were performed on a bench-top setup consisting of an
average power meter and pre-characterized RF cables.

Total Average Power (dBm)= Measured Average Power (dBm)+ DCF (dB)
EIRP (Effective Isotropic Radiated Power) is calculated based on the following formula:




4.3 Test Equipment List
 Manufacturer       Description          Model #              Asset #         Calibration Due

 Rohde &            Power Meter          NRP2                 RF-237          4/14/2017
 Schwarz
 Rohde &            Power Sensor         NRP-Z81              RF-282          4/12/2017
 Schwarz




Report#: R-TR378-FCCIC-RFE-2           Issued: 26 Sep, 2016                         Page 7 of 10
                                     Microsoft EMC Laboratory


4.4 Test Results
Table 1: Average Power

                          Measured          Measured          Maximum       EIRP     EIRP
 Frequency
             Mode          Average          Average            Antenna     (dBm)     (mW)
   (MHz)
                         Power (dBm)       Power (mW)         Gain (dBi)
   2402      GFSK           0.10              1.02              1.73       1.83       1.52
   2440      GFSK           -0.04             0.99              1.73       1.69       1.48
   2480      GFSK           0.06              1.01              1.73       1.79       1.51


Table 2: Max Average Power

                  Maximum                  Maximum             Maximum      EIRP     EIRP
                manufacturer             manufacturer          Antenna     (dBm)     (mW)
 Frequency     stated Average           stated Average           Gain
   (MHz)            Power                    Power               (dBi)
               (adjusted for Tune     (adjusted for Tune up
                 up Tolerance)             Tolerance)
                    (dBm)                    (mW)
    2402              1.8                     1.51                1.73      3.53      2.25
    2440              1.8                     1.51                1.73      3.53      2.25
    2480              1.8                     1.51                1.73      3.53      2.25




Report#: R-TR378-FCCIC-RFE-2          Issued: 26 Sep, 2016                         Page 8 of 10
                                    Microsoft EMC Laboratory


5 SAR Test Exclusion
5.1 FCC
According to FCC KDB 447498 D01 General RF Exposure Guidance v06 (Oct 23, 2015) section
4.3.1, the 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation
distances ≤ 50 mm is defined as

         .              ,                         ,
                                                             [√f(GHz)] ≤ 3.0………….<Eq. 1>
                 .                      ,

where

• f(GHz) is the RF channel transmit frequency in GHz
• Power and distance are rounded to the nearest mW and mm before calculation
• The result is rounded to one decimal place for comparison

Based on manufacturer declaration and when the minimum test separation distance is <5mm, a
distance of 5mm is applied to determine SAR test exclusion.

   Frequency           Average         Average          SAR Exclusion         SAR Exclusion
     (MHz)           Output Power       Output         Threshold using            Limit
                        (dBm)         Power (mW)            Eq. 1
        2480              1.8            1.51               0.63                  <3.0

The EUT is excluded from routine SAR evaluation measurements, since the SAR test exclusion
criteria is met.

5.2 ISED
For devices with a minimum separation distance of 5 mm SAR evaluation is exempt for
transmitters operating with an output power < 4 mW at 2450 MHz (RSS-102 Table 1).
EIRP is used to compare against the exclusion threshold.

  Frequency       Average      Average       Antenna           EIRP    EIRP         SAR
    (MHz)         Output       Output        Gain (dBi)       (dBm)    (mW)      Exclusion
                   Power        Power                                              Limit
                   (dBm)        (mW)                                               (mW)

       2480         1.8          1.51         1.73       3.53       2.25           4
The EUT is excluded from routine SAR evaluation measurements, since the SAR test exclusion
criteria is met.




Report#: R-TR378-FCCIC-RFE-2          Issued: 26 Sep, 2016                        Page 9 of 10
                                    Microsoft EMC Laboratory


                           End of Report




Report#: R-TR378-FCCIC-RFE-2     Issued: 26 Sep, 2016     Page 10 of 10
                               Microsoft EMC Laboratory



Document Created: 2019-10-30 16:54:53
Document Modified: 2019-10-30 16:54:53

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC