R-TR217-FCCIC-RFEx-2

FCC ID: C3K1754

RF Exposure Info

Download: PDF
FCCID_2884706

RF Exposure Evaluation Report
                   For

         MODEL NO. 1754
         FCC ID: C3K1754
         IC ID: 3048A-1754

 Test Report No. R-TR217-FCCIC-MPE-2
       Issue Date: 14 January 2016

      FCC CFR47 Part 2.1093
 Industry Canada RSS-102: Issue 5


             Prepared by
      Microsoft EMC Laboratory
         17760 NE 67th Ct,
     Redmond WA, 98052, U.S.A.
            425-421-9799
       sajose@microsoft.com




          TESTING CERT #3472.01




                                       Report V2.0


1 Record of Revisions
 Revision   Date         Section Page(s)    Summary of Changes               Author/Revised
                                                                             By:
 1.0        12/28/2015   All     All        Version 1.0                      Andy Shen
 2.0        01/14/2016   4,5,6   6-8.       Updated Antenna Gain details.    Andy Shen
                                            Updated SAR exclusion
                                            calculation using max declared
                                            power.




Report#: R-TR217-FCCIC-MPE-2        Issued: 01/14/2016                            Page 2 of 9
                                 Microsoft EMC Laboratory


Table of Contents
1     Record of Revisions ............................................................................................................... 2
2     Deviations from Standards .................................................................................................... 5
3     Facilities and Accreditations .................................................................................................. 5
    3.1     Test Facility .................................................................................................................... 5
    3.2     Accreditations ................................................................................................................. 5
4     Product Description ............................................................................................................... 6
    4.1     Test Configurations ........................................................................................................ 6
5     Peak Conducted Output Power Measurements .................................................................... 7
    5.1     Test Method .................................................................................................................... 7
    5.2     Test Equipment List ........................................................................................................ 7
    5.3     Test Results .................................................................................................................... 7
6     SAR Test Exclusion ............................................................................................................... 8
    6.1     FCC ................................................................................................................................ 8
                   SAR Test Exclusion Criteria .................................................................................... 8
                   FCC SAR Test Exclusion Evaluation ...................................................................... 8
    6.2     IC .................................................................................................................................... 8
                   SAR Test Exclusion Criteria .................................................................................... 8
                   IC SAR Test Exclusion Evaluation .......................................................................... 8




Report#: R-TR217-FCCIC-MPE-2                              Issued: 01/14/2016                                                        Page 3 of 9
                                                     Microsoft EMC Laboratory


                      Test Report Attestation
                                           Microsoft Corporation
                                                Model: 1754
                                             FCC ID: C3K 1754
                                             IC ID: 3048A-1754


Applicable Standards
         Specification                                                       Test Result
 RF Exposure requirements from:                                        Complies
 FCC CFR47 Part 2.1093
 Industry Canada RSS-102 Issue 5



Microsoft EMC Laboratory attests that the product model identified in this report has been tested to and
meets the requirements identified in the above standards. The test results in this report solely pertains to
the specific sample tested, under the conditions and operating modes as provided by the customer.

This report shall not be used to claim product certification, approval, or endorsement by A2LA or any
agency of any Government.
Reproduction, duplication or publication of extracts from this test report requires prior written approval of
Microsoft EMC Laboratory.
This document replaces the previously issued test report #R-TR217-FCCIC-MPE-1 issued by Microsoft
EMC Labs on 12/28/2015.




Written By: Andy Shen                                      Reviewed/ Issued By: Sajay Jose
Radio Test Engineer                                        EMC/RF Compliance Lab Manager




Report#: R-TR217-FCCIC-MPE-2               Issued: 01/14/2016                                     Page 4 of 9
                                        Microsoft EMC Laboratory


2 Deviations from Standards
 None.
3 Facilities and Accreditations
3.1 Test Facility
 All test facilities used to collect the test data are located at
 Microsoft EMC Laboratory,
 17760 NE 67th Ct,
 Redmond WA, 98052, USA

3.2 Accreditations
 The lab is established and follows procedures as outlined in IEC/ISO 17025 and A2LA
 accreditation requirements.
 A2LA Accredited Testing Certificate Number: 3472.01




Report#: R-TR217-FCCIC-MPE-2             Issued: 01/14/2016                      Page 5 of 9
                                     Microsoft EMC Laboratory


4 Product Description
  Company Name:                             Microsoft Corporation

  Address:                                  One Microsoft Way

  City, State, Zip:                         Redmond, WA 98052-6399

  Customer Contact:                         Jennifer Liu

  Functional Description of the EUT:        Wireless Input Device

  Model:                                    1754
  FCC ID:                                   C3K1754

  IC ID:                                    3048A-1754

  Radio Description:                        BT LE (2402- 2480 MHz)

  Declared Output Power:                    -1dBm ±1dB

  Modulation:                               GFSK

  Antenna Type and Gain:                    Internal
                                            3.68 dBi Gain
  EUT Classification:                       DTS

  Equipment Design State:                   EV2-Production equivalent Prototype
                                            FW0.99.14
  Equipment Condition:                      Good

  Test Sample Details:                      SN: 0001274547523 – Conducted
                                            SN: 0000725547523 – Radiated
  RF Exposure Conditions:                   Extremity Exposure, Body Exposure


4.1 Test Configurations
The EUT was preprogrammed to transmit continuously with a constant duty cycle on low,
middle, and high channels. LEDs on the unit indicated the proper mode of operation.

White LED blink once: Low Channel 2402 MHz

White LED blink twice: Mid Channel 2440 MHz

White LED blink three times: High channel 2480 MHz

Yellow LED: Transmitter turn off




Report#: R-TR217-FCCIC-MPE-2           Issued: 01/14/2016                         Page 6 of 9
                                   Microsoft EMC Laboratory


5 Peak Conducted Output Power Measurements
5.1 Test Method
Antenna port conducted measurements were performed on a bench-top setup consisting of a
spectrum analyzer, power meter (as necessary), splitters/combiners (as necessary),
attenuators, and pre-characterized RF cables.

The correction factors between the EUT and the Spectrum Analyzer is added internally in the
Analyzer settings. The plots displayed accounts for these correction factors.

Spectrum Analyzer Settings:
Peak Power Measurements:
Method of KDB 558074.
RBW= 1 MHz
VBW= 3 MHz
Trace Mode= Peak Detector (Max Hold)
Sweep time= Auto
Span= 3 MHz

EIRP was calculated based on the following formula:

              . . . .

5.2 Test Equipment List
 Manufacturer           Description           Model #             Asset #       Calibration Due

    Agilent        Spectrum Analyzer          N9030A             EMC-605            06/15/2016




                    Fig.1. Test setup for antenna port conducted measurements

5.3 Test Results

                            Measured         Measured
                                                              Maximum
 Frequency                     Peak            Peak                         E.I.R.P.    E.I.R.P.
                 Mode                                          Antenna
   (MHz)                    Conducted       Conducted                       (dBm)        (mW)
                                                              Gain (dBi)
                           Power (dBm)      Power (mW)
    2402         BTLE         -0.178          0.959              3.68        3.50         2.24
    2440         BTLE         -0.304          0.932              3.68        3.38         2.18
    2480         BTLE         -0.519          0.887              3.68        3.16         2.07


Report#: R-TR217-FCCIC-MPE-2             Issued: 01/14/2016                             Page 7 of 9
                                      Microsoft EMC Laboratory


6 SAR Test Exclusion
6.1 FCC

        SAR Test Exclusion Criteria
According to FCC KDB 447498 D01 General RF Exposure Guidance v06 (Oct 2015) Section
4.3.1, the 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation
distances ≤ 50 mm is defined as

                  .                  ,                              ,
                                                                             [√f(GHz)] ≤ 3.0
                             .                        ,

where

• f(GHz) is the RF channel transmit frequency in GHz
• Power and distance are rounded to the nearest mW and mm before calculation
• The result is rounded to one decimal place for comparison


        FCC SAR Test Exclusion Evaluation
The EUT was excluded from routine SAR evaluation measurements, since the SAR test
exclusion criteria were met. The min. separation distance of 5mm is used for the calculation.

                          Max Peak
                                                 Calculated SAR             SAR
   Frequency          Conducted Output
                                                   Exclusion              Exclusion            Result
     (MHz)             Power, including
                                                   Threshold                Limit
                       Tolerance (mW)
                                                                                           SAR Test Not
        2480                     1                        0.31               <3.0
                                                                                             Required


6.2 IC

        SAR Test Exclusion Criteria
For devices with a separation distance <5mm, SAR evaluation is exempt for transmitters
operating with an output power < 4mW at 2450 MHz (RSS-102 Table 1).

        IC SAR Test Exclusion Evaluation
The EUT was excluded from routine SAR evaluation measurements, since the SAR test
exclusion criteria were met.

                    Max Peak                                                           SAR
                                            Antenna
 Frequency      Conducted Output                          E.I.R.P       E.I.R.P     Exclusion
                                             Gain                                                 Result
   (MHz)         Power, including                         (dBm)         (mW)          Limit
                                             (dBi)
                 Tolerance (mW)                                                       (mW)
                                                                                                   SAR
    2402                 1                    3.68         3.68          2.33          4         Test Not
                                                                                                 Required




Report#: R-TR217-FCCIC-MPE-2                Issued: 01/14/2016                                  Page 8 of 9
                                         Microsoft EMC Laboratory


                           End of Report




Report#: R-TR217-FCCIC-MPE-2      Issued: 01/14/2016      Page 9 of 9