15U21305-S1V1 SAR_App B System Check Plots

FCC ID: C3K1724

RF Exposure Info

Download: PDF
FCCID_2771956

Test Laboratory: UL Verification Services Inc., SAR Lab 1                    Date/Time: 8/21/2015 9:23:51 AM

20150821 SystemPerformanceCheck-D2450V2 SN 706

Frequency: 2450 MHz; Duty Cycle: 1:1;     Room Ambient Temperature: 24.0°C; Liquid Temperature: 23.0°C
Medium parameters used: f = 2450 MHz; σ = 2.024 S/m; ε r = 51.689; ρ = 1000 kg/m
                                                                                 3

DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE4 Sn1352; Calibrated: 11/7/2014
- Probe: EX3DV4 - SN7356; ConvF(7.54, 7.54, 7.54); Calibrated: 4/22/2015;
- Sensor-Surface: 2.5mm (Mechanical Surface Detection)
- Phantom: ELI-A v5.0; Type: QDOVA002AA; Serial: TP 1194

Body/Pin=100 mW/Area Scan (8x8x1): Measurement grid: dx=12mm, dy=12mm
Maximum value of SAR (measured) = 7.00 W/kg

Body/Pin=100 mW/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm
Reference Value = 56.473 V/m; Power Drift = 0.16 dB
Peak SAR (extrapolated) = 11.3 W/kg
SAR(1 g) = 5.41 W/kg; SAR(10 g) = 2.49 W/kg
Maximum value of SAR (measured) = 7.73 W/kg




                      0 dB = 7.73 W/kg = 8.88 dBW/kg




                                                                                                               Plot No. 1


Test Laboratory: UL Verification Services Inc., SAR Lab 1   Date/Time: 8/21/2015 9:44:23 AM

20150821 SystemPerformanceCheck-D2450V2 SN 706
Frequency: 2450 MHz; Duty Cycle: 1:1

Body/Pin=100 mW/Z Scan (1x1x21): Measurement grid: dx=20mm, dy=20mm, dz=5mm
Maximum value of SAR (measured) = 6.37 W/kg




                                                                                              Plot No. 2


Test Laboratory: UL Verification Services Inc., SAR Lab 4                    Date/Time: 8/17/2015 1:01:54 PM

20150817_SystemPerformanceCheck-D5GHzV2 SN 1138

Frequency: 5600 MHz; Duty Cycle: 1:1;     Room Ambient Temperature: 24.0°C; Liquid Temperature: 23.0°C
Medium parameters used: f = 5600 MHz; σ = 5.886 S/m; ε r = 46.998; ρ = 1000 kg/m
                                                                                 3

DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE4 Sn1377; Calibrated: 8/27/2014
- Probe: EX3DV4 - SN3989; ConvF(4, 4, 4); Calibrated: 3/17/2015;
- Sensor-Surface: 1.4mm (Mechanical Surface Detection)
- Phantom: ELI A (v5.0); Type: QDOVA001BB; Serial: S/n:1212

Body/5.6 GHz, Pin=100mW/Area Scan (7x7x1): Measurement grid: dx=10mm, dy=10mm
Maximum value of SAR (measured) = 22.5 W/kg

Body/5.6 GHz, Pin=100mW/Zoom Scan (8x8x7)/Cube 0: Measurement grid: dx=4mm, dy=4mm,
dz=1.4mm
Reference Value = 55.99 V/m; Power Drift = 0.01 dB
Peak SAR (extrapolated) = 37.7 W/kg
SAR(1 g) = 8.73 W/kg; SAR(10 g) = 2.42 W/kg
Maximum value of SAR (measured) = 20.8 W/kg




                      0 dB = 20.8 W/kg = 13.18 dBW/kg




                                                                                                               Plot No. 3


Test Laboratory: UL Verification Services Inc., SAR Lab 4   Date/Time: 8/17/2015 1:23:07 PM

20150817_SystemPerformanceCheck-D5GHzV2 SN 1138
Frequency: 5600 MHz; Duty Cycle: 1:1

Body/5.6 GHz, Pin=100mW/Z Scan (1x1x21): Measurement grid: dx=20mm, dy=20mm, dz=5mm
Maximum value of SAR (measured) = 15.6 W/kg




                                                                                              Plot No. 4



Document Created: 2015-09-25 19:00:02
Document Modified: 2015-09-25 19:00:02