R-TR190-FCCIC-DFS-2

FCC ID: C3K1703

Test Report

Download: PDF
FCCID_2770919

  RADIO TEST REPORT
                  For

        MODEL NO. 1703
        FCC ID: C3K1703
        IC ID: 3048A-1703

Test Report No. R-TR190-FCCIC-DFS-2
    Issue Date: September 29, 2015

  FCC CFR47 Part 15 Subpart E
Industry Canada RSS-247 Issue 1


            Prepared by
     Microsoft EMC Laboratory
        17760 NE 67th Ct,
    Redmond WA, 98052, U.S.A.
           425-421-9799
      sajose@microsoft.com




         TESTING CERT #3472.01




                                      Rev 2.0


1 Record of Revisions
 Revision   Date         Section Page(s)        Summary of Changes            Author/Revised
                                                                              By:
 1.0        09/15/2015   All        All          First Version                Daniel Salinas
 2.0        09/29/2015   4, 6, 8.3, 7, 8, 16, 17 Include test sample serial   Daniel Salinas
                         8.4                     number;
                                                 Include FCC ID of Router;
                                                 Remove 80 MHz data




Report#: R-TR190-FCCIC-DFS-2        Issued: September 29, 2015                    Page 2 of 19
                                   Microsoft EMC Laboratory


Table of Contents
1     Record of Revisions ............................................................................................................... 2
2     Deviations from Standards .................................................................................................... 6
3     Facilities and Accreditations .................................................................................................. 6
    3.1     Test Facility .................................................................................................................... 6
    3.2     Accreditations ................................................................................................................. 6
    3.3     Test Equipment .............................................................................................................. 6
4     Product Description ............................................................................................................... 7
    4.1     Test Configurations ........................................................................................................ 7
    4.2     Environmental Conditions ............................................................................................... 7
    4.3     Equipment Modifications ................................................................................................ 7
    4.4     Dates of Testing ............................................................................................................. 7
5     Test Results Summary .......................................................................................................... 8
6     Test Equipment List ............................................................................................................... 8
7     Test Method ........................................................................................................................... 9
    7.1     Antenna port conducted measurements ......................................................................... 9
    7.2     Test Setup Diagrams ...................................................................................................... 9
8     Test Results ......................................................................................................................... 10
    8.1     In-service monitoring .................................................................................................... 10
                   Test Requirement: ................................................................................................. 10
                   Test Method: ......................................................................................................... 10
                   Limits: .................................................................................................................... 10
                   Test Results: ......................................................................................................... 10
    8.2     Channel Availability Check Time .................................................................................. 11
                   Test Requirement: ................................................................................................. 11
                   Test Method: ......................................................................................................... 11
                   Limits: .................................................................................................................... 11
                   Test Results: ......................................................................................................... 11
    8.3     Channel Move Time ..................................................................................................... 12
                   Test Requirement: ................................................................................................. 12
                   Test Method: ......................................................................................................... 12
                   Limits: .................................................................................................................... 12
                   Test Results: ......................................................................................................... 12
                   Test Data ............................................................................................................... 13
Report#: R-TR190-FCCIC-DFS-2                          Issued: September 29, 2015                                                Page 3 of 19
                                                    Microsoft EMC Laboratory


 8.4   Channel Closing Transmission Time ............................................................................ 17
             Test Requirement: ................................................................................................. 17
             Test Method: ......................................................................................................... 17
             Limits: .................................................................................................................... 17
             Test Results: ......................................................................................................... 17
             Test Data ............................................................................................................... 17
 8.5   Non-Occupancy Period ................................................................................................ 18
             Test Requirement: ................................................................................................. 18
             Test Method: ......................................................................................................... 18
             Limits: .................................................................................................................... 18
             Test Results: ......................................................................................................... 18
             Test Data: .............................................................................................................. 18




Report#: R-TR190-FCCIC-DFS-2                    Issued: September 29, 2015                                                Page 4 of 19
                                              Microsoft EMC Laboratory


                       Test Report Attestation
                                           Microsoft Corporation
                                                Model: 1703
                                             FCC ID: C3K1703
                                             IC ID: 3048A-1703


 Applicable Standards
          Specification                                                                 Test Result
  FCC CFR47 Rule Parts 15.407- DFS                                                           Pass

  Industry Canada RSS-247 Issue 1- DFS                                                       Pass



 Microsoft EMC Laboratory attests that the product model identified in this report has been tested to and
 meets the requirements identified in the above standards. The test results in this report solely pertains to
 the specific sample tested, under the conditions and operating modes as provided by the customer.

 This report shall not be used to claim product certification, approval, or endorsement by A2LA or any
 agency of any Government. Reproduction, duplication or publication of extracts from this test report is
 prohibited and requires prior written approval of Microsoft EMC Laboratory.

 This test report replaces Microsoft test report R-TR190-FCCIC-DFS-1 issued on 09/15/2015.




Written By: Daniel Salinas                            Reviewed/ Issued By: Sajay Jose
Radio Test Engineer                                   EMC/RF Compliance Lab Manager




Report#: R-TR190-FCCIC-DFS-2             Issued: September 29, 2015                              Page 5 of 19
                                        Microsoft EMC Laboratory


2 Deviations from Standards
 None.
3 Facilities and Accreditations
3.1 Test Facility
 All test facilities used to collect the test data are located at
 Microsoft EMC Laboratory,
 17760 NE 67th Ct,
 Redmond WA, 98052, USA

3.2 Accreditations
 The lab is established and follows procedures as outlined in IEC/ISO 17025 and A2LA
 accreditation requirements.
 A2LA Accredited Testing Certificate Number: 3472.01
 FCC Registration Number: US1141
 IC Site Registration Numbers: 3048A-1, 3048A-2, 3048A-3, 3048A-4

3.3 Test Equipment
 The calibrations of the measuring instruments, including any accessories that may affect such
 calibration, are checked frequently to assure their accuracy. Adjustments are made and
 correction factors applied in accordance with instructions contained in the user manual for the
 measuring equipment.




Report#: R-TR190-FCCIC-DFS-2           Issued: September 29, 2015                    Page 6 of 19
                                     Microsoft EMC Laboratory


4 Product Description
  Company Name:                               Microsoft Corporation

  Address:                                    One Microsoft Way

  City, State, Zip:                           Redmond, WA 98052-6399

  Customer Contact:                           Sahithi Kandula

  Functional Description of the EUT:          Handheld computing device with         802.11    2x2
                                              a/b/g/n/ac WLAN, Bluetooth Radios
  Model:                                      1703
  FCC ID:                                     C3K1703

  IC ID:                                      3048A-1703

  Radio Description:                          WLAN 802.11a/n/ac with 20MHz, 40MHz and 80MHz
                                              Signal Bandwidths
  Modulation:                                 OFDM – BPSK, QPSK, 16-QAM, 64-QAM, 256-QAM

  Antenna Type and Gain:                      Internal
                                              4dBi
  EUT Classification:                         UNII – Slave Device without radar detection

  Equipment Design State:                     EV3B

  Equipment Condition:                        Good

  Test Sample Details:                        S/N: 000112352157


4.1 Test Configurations
The device was setup in normal operation and connected wirelessly to an 802.11 access point
on 20 MHz, 40 MHz and 80 MHz bandwidths. A host laptop was configured to transmit traffic by
using video to the EUT. The Aeroflex PXI 3001C DFS test system was used to monitor traffic
and generate radar pulses.

4.2 Environmental Conditions
Ambient air temperature of the test site was within the range of 10 ⁰C to 40 ⁰C (50 ⁰F to 104 ⁰F)
unless the EUT specified testing over a different temperature range. Humidity levels were in the
range of 10% to 90% relative humidity. Testing conditions were within tolerance and any
deviations required from the EUT are reported.

4.3 Equipment Modifications
No modifications were made during testing.

4.4 Dates of Testing
Testing was performed from August 17th - 18th, 2015.




Report#: R-TR190-FCCIC-DFS-2           Issued: September 29, 2015                    Page 7 of 19
                                   Microsoft EMC Laboratory


5 Test Results Summary
                                                 FCC CFR 47/           Limit        Test
              Test Description
                                                 IC Rule Part                      Result

     In-Service Monitoring                 15.407(h)(2)(iv)      Monitor co-        N/A*
                                           RSS-247 [6.3]         channel radar

     Channel Availability Check            15.407 (h)(2)(ii)     60s detection      N/A*
                                           RSS-247 [6.3]

     Channel Move Time                     15.407 (h)(2)(iii)    10s                Pass
                                           RSS-247 [6.3]

     Channel Closing Time                  15.407 (h)(2)(iii)    200ms              Pass
                                           RSS-247 [6.3]

     Non-occupancy Period                  15.407 (h)(2)(iv)     30 minutes         Pass
                                           RSS-247 [6.3]
      *Note: The EUT is a slave device with out radar detection.


6 Test Equipment List

                                                                                 Calibration
    Manufacturer     Description       Model #         Asset #     FCC ID
                                                                                    Due
       Aeroflex      PXI Chassis       3001C           RF-132          N/A        3/9/2016
                        Cisco
                                        AIR-
                     Aironet ISO                                 LDK 102061
        Cisco                        AP1252AG-         RF-331                       N/A
                       Access                                    LDK 102062
                                       A-K9
                        Point
                      Spectrum
        Agilent                        N9030A          RF-011          N/A       02/29/2016
                      Analyzer




Report#: R-TR190-FCCIC-DFS-2        Issued: September 29, 2015                   Page 8 of 19
                                   Microsoft EMC Laboratory


7 Test Method
7.1 Antenna port conducted measurements
Antenna port conducted measurements were performed on a bench-top setup consisting of a
spectrum analyzer, power meter (as necessary), splitters/combiners (as necessary),
attenuators, and pre-characterized RF cables. The Aeroflex PXI 3001C DFS test system
monitored traffic and generated radar bursts.

The correction factors between the EUT, support equipment, radar test generator and the
spectrum analyzer is added internally in the Areoflex test system.

7.2 Test Setup Diagrams




                  Fig.1. Test Setup for Antenna port conducted measurements




Report#: R-TR190-FCCIC-DFS-2       Issued: September 29, 2015                     Page 9 of 19
                                  Microsoft EMC Laboratory


8 Test Results
8.1 In-service monitoring

       Test Requirement:
FCC CFR 47 Rule Part 15.407 (h)(2)(iv)

Industry Canada RSS-247 [6.3]

       Test Method:
Measurements were performed according to the procedures defined in KDB 905462 D02 UNII
DFS Compliance Procedures New Rules v01r02

       Limits:
An LE-LAN device shall be able to monitor the operating channel to check that a co-channel
radar has not moved or started operation within range of the LE-LAN device. During in-service
monitoring, the LE-LAN radar detection function continuously searches for radar signals
between normal LE-LAN transmissions.

       Test Results:
Not Applicable. The EUT is a slave device without radar detection.




Report#: R-TR190-FCCIC-DFS-2        Issued: September 29, 2015                    Page 10 of 19
                                   Microsoft EMC Laboratory


8.2 Channel Availability Check Time

       Test Requirement:
FCC CFR 47 Rule Part 15.407 (h)(2)(iv)

Industry Canada RSS-247 [6.3]

       Test Method:
Measurements were performed according to the procedures defined in KDB 905462 D02 UNII
DFS Compliance Procedures New Rules v01r02

        Limits:
The EUT shall check whether there is a radar system already operating on the channel
before it initiates a transmission on a channel and when it moves to a channel. The device
may start using the channel if no radar signal with a power level greater than the
interference threshold value specified in Section 6.3(1) above is detected within 60
seconds.

       Test Results:
Not Applicable. The EUT is a slave device without radar detection.




Report#: R-TR190-FCCIC-DFS-2        Issued: September 29, 2015                 Page 11 of 19
                                   Microsoft EMC Laboratory


8.3 Channel Move Time

        Test Requirement:
FCC CFR 47 Rule Part 15.407 (h)(2)(iv)

Industry Canada RSS-247 [6.3]

        Test Method:
Measurements were performed according to the procedures defined in KDB 905462 D02 UNII
DFS Compliance Procedures New Rules v01r02

        Limits:
After a radar signal is detected, the device shall cease all transmissions on the operating
channel within 10 seconds.

        Test Results:
Pass.

The EUT ceased transmission on the channel within 10s.




Report#: R-TR190-FCCIC-DFS-2       Issued: September 29, 2015                     Page 12 of 19
                                  Microsoft EMC Laboratory


      Test Data

8.3.5.1 Radar Burst Level




                  Figure 1. Radar Burst Level at -63dBm: Radar Type 0




Report#: R-TR190-FCCIC-DFS-2     Issued: September 29, 2015             Page 13 of 19
                               Microsoft EMC Laboratory


8.3.5.2 Channel Loading




                               Figure 2. Channel Loading




Report#: R-TR190-FCCIC-DFS-2     Issued: September 29, 2015   Page 14 of 19
                                Microsoft EMC Laboratory


8.3.5.3 Channel Move Time 20 MHz Bandwidth




                   Figure 3. Channel Move Time 20 MHz Bandwidth




Report#: R-TR190-FCCIC-DFS-2    Issued: September 29, 2015        Page 15 of 19
                               Microsoft EMC Laboratory


8.3.5.4 Channel Move Time 40 MHz Bandwidth




                   Figure 4. Channel Move Time 40 MHz Bandwidth




Report#: R-TR190-FCCIC-DFS-2    Issued: September 29, 2015        Page 16 of 19
                               Microsoft EMC Laboratory


8.4 Channel Closing Transmission Time

        Test Requirement:
FCC CFR 47 Rule Part 15.407 (h)(2)(iii)

Industry Canada RSS-247 [6.3]

        Test Method:
Measurements were performed according to the procedures defined in KDB 905462 D02 UNII
DFS Compliance Procedures New Rules v01r02

        Limits:
After the radar burst has been applied, the EUT shall cease normal transmission on the
channel within 200 ms starting at the beginning of the channel move time. Control signaling
required to facilitate a channel move (an aggregate of 60 ms) over the remaining 10-second
period of the channel move time is permissible.

        Test Results:
Pass.

The EUT ceased transmission on the channel within the allotted time.

        Test Data
                                                 Channel
                   Channel   Aggregate                            Aggregate
   Channel                                        Closing
                   Closing    Control                              Control
  Bandwidth                                    Transmission                         Result
                Transmission Signaling                          Signaling Time
    (MHz)                                       Time Limit
                  Time (ms)  Time (ms)                            Limit (ms)
                                                   (ms)
        20          25.706            0             200                60           Pass
        40          97.821            0             200                60           Pass




Report#: R-TR190-FCCIC-DFS-2       Issued: September 29, 2015                    Page 17 of 19
                                  Microsoft EMC Laboratory


8.5 Non-Occupancy Period

        Test Requirement:
FCC CFR 47 Rule Part 15.407 (h)(2)(iv)

Industry Canada RSS-247 [6.3]

        Test Method:
Measurements were performed according to the procedures defined in KDB 905462 D02 UNII
DFS Compliance Procedures New Rules v01r02

       Limits:
A channel that has been flagged as containing a radar system, either by a channel
availability check or in-service monitoring, is subject to a non-occupancy period of at least
30 minutes. The non-occupancy period starts at the time when the radar system is
detected.

        Test Results:
Pass.

The EUT ceased transmission on the channel within 10s.

        Test Data:
Plot shown for 2000 secs sweep time.




                        Figure 5. 30 Minute Non-Occupancy Period
Report#: R-TR190-FCCIC-DFS-2        Issued: September 29, 2015                    Page 18 of 19
                                   Microsoft EMC Laboratory


                         End of Report




Report#: R-TR190-FCCIC-DFS-2    Issued: September 29, 2015   Page 19 of 19
                               Microsoft EMC Laboratory



Document Created: 2015-09-29 13:52:19
Document Modified: 2015-09-29 13:52:19

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC