R-TR190-FCCIC-WLAN-1 Part 1 of 4

FCC ID: C3K1703

Test Report

Download: PDF
FCCID_2770897

   RADIO TEST REPORT
                  For

        MODEL NO. 1703
         FCC ID: C3K1703
        IC ID: 3048A-1703

Test Report No. R-TR190-FCCIC-WLAN-1
        Issue Date: 09/15/2015

   FCC CFR47 Part 15 Subpart C
 Industry Canada RSS-247 Issue 1


             Prepared by
      Microsoft EMC Laboratory
         17760 NE 67th Ct,
     Redmond WA, 98052, U.S.A.
            425-421-9799
       sajose@microsoft.com




         TESTING CERT #3472.01




                                       Rev 2.0


1 Record of Revisions

  Revision   Date         Section Page(s)     Summary of Changes   Author/Revised
                                                                   By:
  1.0        09/15/2015   All     All         First Version        Andy Shen




Report#: R‐TR190‐FCCIC‐WLAN‐1     Issued: September 15, 2015           Page 2 of 151
                                   Microsoft EMC Laboratory


Table of Contents
1 Record of Revisions ............................................................................................................................... 2
2      Deviations from Standards ................................................................................................................... 7
3      Facilities and Accreditations ................................................................................................................. 7
    3.1       Test Facility ................................................................................................................................... 7
    3.2       Accreditations ............................................................................................................................... 7
    3.3       Test Equipment ............................................................................................................................. 7
4      Measurement Uncertainty.................................................................................................................... 7
5      Product Description .............................................................................................................................. 8
    5.1       Test Configurations ....................................................................................................................... 8
    5.2       Environmental Conditions ............................................................................................................ 8
    5.3       Antenna Requirements ................................................................................................................. 8
    5.4       Equipment Modifications .............................................................................................................. 8
    5.5       Dates of Testing ............................................................................................................................ 8
6      Test Results Summary ........................................................................................................................... 9
7      Test Equipment List ............................................................................................................................. 10
8      Test Site Description ........................................................................................................................... 12
    8.1       Radiated Emissions Test Site ....................................................................................................... 12
                     Radiated Measurements in 30M‐ 1000 MHz ...................................................................... 12
                     Radiated Measurements above 1GHz ................................................................................ 12
    8.2       Antenna port conducted measurements .................................................................................... 12
    8.3       Test Setup Diagrams ................................................................................................................... 12
9      Test Results‐ Conducted ..................................................................................................................... 15
    9.1       6‐dB Bandwidth........................................................................................................................... 15
                     Test Requirement:............................................................................................................... 15
                     Test Method: ....................................................................................................................... 15
                     Limits: .................................................................................................................................. 15
                     Test Results: ........................................................................................................................ 15
                     Test Data: ............................................................................................................................ 17
    9.2       99% Bandwidth ........................................................................................................................... 29
                     Test Requirement:............................................................................................................... 29
                     Test Method: ....................................................................................................................... 29

Report#: R‐TR190‐FCCIC‐WLAN‐1                             Issued: September 15, 2015                                                          Page 3 of 151
                                                             Microsoft EMC Laboratory


               Limit: ................................................................................................................................... 29
               Test Results: ........................................................................................................................ 29
               Test Data: ............................................................................................................................ 31
  9.3   Output Power.............................................................................................................................. 43
               Test Requirement:............................................................................................................... 43
               Test Method: ....................................................................................................................... 43
               Limits: .................................................................................................................................. 43
               Test Results: ........................................................................................................................ 44
               Test Data: ............................................................................................................................ 46
  9.4   Power Density ............................................................................................................................. 58
               Test Requirement:............................................................................................................... 58
               Test Method: ....................................................................................................................... 58
               Limits: .................................................................................................................................. 58
               Test Results: ........................................................................................................................ 59
               Test Data: ............................................................................................................................ 61
  9.5   Conducted Spurious Emissions ................................................................................................... 73
               Test Requirement:............................................................................................................... 73
               Test Method: ....................................................................................................................... 73
               Limits: .................................................................................................................................. 73
               Test Result: .......................................................................................................................... 73
               Test Data: ............................................................................................................................ 74
  9.6   Conducted Band Edge Emissions .............................................................................................. 122
               Test Requirement:............................................................................................................. 122
               Test Method: ..................................................................................................................... 122
               Limits: ................................................................................................................................ 122
               Test Result: ........................................................................................................................ 122
               Test Data: .......................................................................................................................... 123
  9.7   Radiated Spurious and Band Edge Emissions ........................................................................... 132
               Test Requirement:............................................................................................................. 132
               Test Method: ..................................................................................................................... 132
               Limits: ................................................................................................................................ 133
               Test Result: ........................................................................................................................ 133

Report#: R‐TR190‐FCCIC‐WLAN‐1                       Issued: September 15, 2015                                                          Page 4 of 151
                                                      Microsoft EMC Laboratory


              Test Data: .......................................................................................................................... 134
  9.8   AC Line Conducted Emissions ................................................................................................... 148
              Test Requirements ............................................................................................................ 148
              Test Method ...................................................................................................................... 148
              Limit .................................................................................................................................. 148
              Test Result: ........................................................................................................................ 148
              Test Data: .......................................................................................................................... 149




Report#: R‐TR190‐FCCIC‐WLAN‐1                     Issued: September 15, 2015                                                          Page 5 of 151
                                                     Microsoft EMC Laboratory


                         Test Report Attestation
                                          Microsoft Corporation
                                               Model: 1703
                                            FCC ID: C3K1703
                                            IC ID: 3048A-1703


Applicable Standards
         Specification                                        Test Result
  FCC CFR47 Rule Parts 15.209, 15.247                   Pass
  Industry Canada RSS-247 Issue 1                       Pass



Microsoft EMC Laboratory attests that the product model identified in this report has been tested to and
meets the requirements identified in the above standards. The test results in this report solely pertains to
the specific sample tested, under the conditions and operating modes as provided by the customer.

This report shall not be used to claim product certification, approval, or endorsement by A2LA or any
agency of any Government. Reproduction, duplication or publication of extracts from this test report is
prohibited and requires prior written approval of Microsoft EMC Laboratory.




 Written By: Andy Shen                                 Reviewed/ Issued By: Sajay Jose
 Radio Test Engineer                                   EMC/RF Compliance Lab Manager




Report#: R‐TR190‐FCCIC‐WLAN‐1          Issued: September 15, 2015                               Page 6 of 151
                                         Microsoft EMC Laboratory


2 Deviations from Standards
 None.
3 Facilities and Accreditations
3.1 Test Facility
 All test facilities used to collect the test data are located at
 Microsoft EMC Laboratory,
 17760 NE 67th Ct,
 Redmond WA, 98052, USA

3.2 Accreditations
 The lab is established and follows procedures as outlined in IEC/ISO 17025 and A2LA
 accreditation requirements.
 A2LA Accredited Testing Certificate Number: 3472.01
 FCC Registration Number: US1141
 IC Site Registration Numbers: 3048A-1, 3048A-2, 3048A-3, 3048A-4

3.3 Test Equipment
 The site and related equipment are constructed in conformance with the requirements of ANSI
 C63.4 2014, CISPR 16-1-1 and other equivalent applicable standards. Test site requirements
 for measurements above 1 GHz are in accordance with ANSI C63.4 2009. ANSI C63.10 2013
 and the appropriate KDB test methods were followed.
 The calibrations of the measuring instruments, including any accessories that may affect such
 calibration, are checked frequently to assure their accuracy. Adjustments are made and
 correction factors applied in accordance with instructions contained in the user manual for the
 measuring equipment.


4 Measurement Uncertainty
 The following measurement uncertainty levels have been estimated for tests performed on
 the product, as specified in CISPR 16-4-2. This represents an expanded uncertainty
 expressed at 95% confidence level using a coverage factor k=2. These levels are for
 reference only and not included to determine product compliance.
 Expanded uncertainty calculations are available upon request.

                   Test item                                        Value (dB)
   Radiated disturbance (30 MHz to 1 GHz)                              6.10
   Radiated disturbance (1 GHz to 18 GHz)                              4.80
   Conducted Disturbance at Mains Port                                 3.30




Report#: R‐TR190‐FCCIC‐WLAN‐1         Issued: September 15, 2015                    Page 7 of 151
                                       Microsoft EMC Laboratory


5 Product Description
  Company Name:              Microsoft Corporation
  Address:                   One Microsoft Way
  City, State, Zip:          Redmond, WA 98052-6399
  Customer Contact:          Sahithi Kandula
  Functional Description of Portable Computing device with
  the EUT:                  2x2 802.11 a/b/g/n/ac WLAN and BT 4.0 Radios
  Model:                     1703
  FCC ID:                    C3K1703
  IC ID:                     3048A-1703
  Radio Description:         WLAN 802.11 b/g/n 2.4GHz – 2.4835GHz
  Modulation:                CCK, BPSK, OFDM, and QAM modulation
  Antenna Type and Gain: Internal
                         4dBi
  EUT Classification:    DTS
  Equipment Design State: EV3B
  Equipment Condition:       Good
  Test Sample Details:       S/N: 000133752157 (Conducted Sample)
                             S/N: 000181452357 (Radiated Sample)

5.1 Test Configurations
Test software “WiFi Tool” (V2.7.4) provided by the customer and “Lab Tool” (V2.0.0.77) from the
module vendor was used to program the EUT to transmit continuously in 802.11 b/g/n modes.
Channel numbers 1, 6 and 11/13 are used as the Low/Mid/High channels of test.

5.2 Environmental Conditions
Ambient air temperature of the test site was within the range of 10 ⁰C to 40 ⁰C (50 ⁰F to 104 ⁰F)
unless the EUT specified testing over a different temperature range. Humidity levels were in the
range of 10% to 90% relative humidity. Testing conditions were within tolerance and any
deviations required from the EUT are reported.

5.3 Antenna Requirements
The antennas are permanently attached and there are no provisions for connection to an
external antenna.

5.4 Equipment Modifications
No modifications were made during testing.

5.5 Dates of Testing
Testing was performed on July 8th-9th, July 21st, July 23rd-24th, August 21st, August 25st, and
September 02st 2015.


Report#: R‐TR190‐FCCIC‐WLAN‐1       Issued: September 15, 2015                          Page 8 of 151
                                      Microsoft EMC Laboratory


6 Test Results Summary
                                                FCC CFR 47/        Limit           Test
              Test Description
                                                IC Rule Part                      Result

     6dB Bandwidth                          15.247 (a)(2)        > 500kHz          Pass
                                            RSS-247 [5.2]

     Output Power                           15.247 (b)(3)        < 1 Watt          Pass
                                            RSS-247 [5.4]

     Power Spectral Density                 15.247 (e)         < 8dBm/3kHz         Pass
                                            RSS-247 [5.2]

     Conducted Band Edge/Spurious           15.247 (d)         At least 20dBc      Pass
     Emissions                              RSS-247 [5.5]

     Radiated Spurious Emissions/           15.205, 15.209      FCC CFR 47
     Restricted Band Emissions              RSS-247 [5.5]       15.209 limits      Pass
                                            RSS-Gen [8.9]      RSS-Gen [8.9]

     AC Power line Conducted                15.207             FCC CFR 47          Pass
     Emissions                              RSS-Gen [8.8]      15.207 limits
                                                                RSS-Gen
                                                                   [8.8]]




Report#: R‐TR190‐FCCIC‐WLAN‐1    Issued: September 15, 2015                     Page 9 of 151
                                    Microsoft EMC Laboratory


7 Test Equipment List
The site and related equipment are in conformance with the requirements of ANSI C63.4,
CISPR 16-1-1, and other equivalent applicable standards.

 Equipment used for Radiated and Conducted Measurements

  Manufacturer       Description            Model #             Asset #    Calibration Due
 Rohde &           EMI Test                  ESU40              RF-192        4/14/2016
 Schwarz           Receiver
 Rohde &           EMI Test                  ESU40              RF-012        4/12/2016
 Schwarz           Receiver
 Agilent           Spectrum                 N9030A              EMC-607       6/16/2016
                   Analyzer
 Rohde &           Signal Analyzer           FSV40              RF-195        4/10/2016
 Schwarz
 Rohde &           Signal Analyzer           FSV40              RF-245        4/10/2016
 Schwarz
 Sunol Sciences    Antenna -                  JB6               EMC-008        3/4/2016
                   Broadband
 ETS-Lindgren      Antenna                    3117              RF-139         4/9/2016

 ETS-Lindgren      Antenna                    3117              RF-138        5/13/2016

 ETS-Lindgren      Antenna -                3160-09             RF-179        4/30/2016
                   Standard Gain
 ETS-Lindgren      Antenna -                3160-10             RF-038        4/30/2016
                   Standard Gain
 Rohde &           Custom Filter          SFUNIT RX             RF-323        3/21/2016
 Schwarz           Bank+PreAmp
 Rohde &           Custom Filter          SFUNIT RX             RF-324        3/21/2016
 Schwarz           Bank
 Rohde &           Pre-Amp                  TS-PR26             RF-042         1/6/2016
 Schwarz
 Rohde &           Pre-Amp                  TS-PR40             RF-200         1/6/2016
 Schwarz
 Rohde &           Switch and               OSP130              RF-249         1/9/2016
 Schwarz           Control Unit
 Rohde &           Switch and               OSP150              RF-250         1/9/2016
 Schwarz           Control Unit
 Rohde &           Switch and               OSP130              RF-018        12/18/2015
 Schwarz           Control Unit
 Rohde &           Switch and               OSP150              RF-019        12/18/2015
 Schwarz           Control Unit




Report#: R‐TR190‐FCCIC‐WLAN‐1      Issued: September 15, 2015                   Page 10 of 151
                                     Microsoft EMC Laboratory


 Maturo            Antenna Tower             NCD                RF-002         N/A
                   Controller
 Maturo            Device                   TD1.5               RF-003         N/A
                   Positioner
 Maturo            System                  NCD-120              RF-327         N/A
                   Controller
 Sunol Sciences    System                  SC110V               RF-001         N/A
                   Controller
 Madge Tech        THP Monitor         PRH Temp 2000            EMC-681     11/5/2015

 Madge Tech        THP Monitor         PRH Temp 2000            EMC-171        N/A

 Fluke             Multimeter                87V                EMC-193      4/9/2016

 Rohde &           Software             EMC-32 V9.15              N/A          N/A
 Schwarz
 Huber Suhner      RF Cable                  102A               RF-272       1/6/2016

 Huber Suhner      RF Cable             Sucoflex 102A           RF-269      3/21/2016



 Equipment used for Line Conducted Emissions Measurement
  Manufacturer       Description           Model #              Asset #   Calibration Due
 Rohde &           EMI Test                ESR 3                EMC-669      11/3/2015
 Schwarz           Receiver
 Teseq             LISN                    NNB 51               EMC-187     10/11/2015

 Teseq             LISN                    NNB 51               EMC-642     10/11/2015

 Micro-Coax        RF Cable               UFA210A-1-            EMC-367      8/6/2016
                                         1800-50U50U
 Madge Tech        THP Monitor          PRHTemp2000             EMC-837     6/23/2016

 ETS               TILE SW                  Ver 7.0               N/A          N/A




Report#: R‐TR190‐FCCIC‐WLAN‐1      Issued: September 15, 2015                  Page 11 of 151
                                    Microsoft EMC Laboratory


8 Test Site Description
8.1 Radiated Emissions Test Site
Radiated measurements are performed in a 3m semi-anechoic chamber, which meets NSA
requirements for the frequency range of 30MHz to 1000MHz. For measurements above 1 GHz,
absorbers with a 2.4m X 2.4m configuration are laid out on the ground plane between the
Receiving antenna and the EUT in accordance with the requirements of ANSI C63.4:2009.

       Radiated Measurements in 30M‐ 1000 MHz
The EUT is positioned on a Turntable at a height of 80cm using a non-conducting table. A
Linearly polarized broadband antenna is positioned at 3m from the EUT periphery. The turntable
is rotated 360 degrees and the antenna height varied from 1m to 4m to determine the highest
emissions. This is repeated for both Horizontal and Vertical Polarizations of the Measurement
Antenna. The EUT is also rotated about its three orthogonal orientations to investigate
emissions.

       Radiated Measurements above 1GHz
The EUT is positioned on a Turntable at a height of 150cm using a device positioner. A Linearly
polarized antenna is positioned at 3m from the EUT periphery. Guidelines in ANSI C63.10 2013
were followed with respect to maximizing the emissions. The turntable is rotated 360 degrees,
the antenna height maintained at 150cm and the device positioner rotated about it’s horizontal
axis to determine the highest emissions. This is repeated for both Horizontal and Vertical
Polarizations of the Measurement Antenna. Measurements above 18GHz were performed at a
distance of 1m.

8.2 Antenna port conducted measurements
All antenna port conducted measurements are performed on a bench-top setup consisting of a
Spectrum Analyzer, Power Meter (as necessary), Splitters/Combiners (as necessary),
Attenuators, and pre-characterized RF cables.

The correction factors between the EUT and the Spectrum Analyzer is added internally in the
Analyzer settings. The plots displayed accounts for these correction factors.

8.3 Test Setup Diagrams




                  Fig.1. Test Setup for Antenna port conducted measurements



Report#: R‐TR190‐FCCIC‐WLAN‐1      Issued: September 15, 2015                      Page 12 of 151
                                    Microsoft EMC Laboratory


             Fig.2. Test Setup for Radiated measurements in 30MHz- 1GHz Range




              Fig.3. Test Setup for Radiated measurements in 1GHz- 18GHz Range




Report#: R‐TR190‐FCCIC‐WLAN‐1    Issued: September 15, 2015                      Page 13 of 151
                                   Microsoft EMC Laboratory


                    Fig.4. Test Setup for Radiated measurements >18GHz




Report#: R‐TR190‐FCCIC‐WLAN‐1   Issued: September 15, 2015               Page 14 of 151
                                  Microsoft EMC Laboratory


9 Test Results‐ Conducted
9.1 6‐dB Bandwidth

       Test Requirement:
FCC CFR 47 Rule Part 15.247 (a)(2)

Industry Canada RSS-247 [5.2]

       Test Method:
Measurements are performed according to the procedure defined in KDB 558074- Guidance for
Performing Compliance Measurements on Digital Transmission Systems (DTS) Operating
Under §15.247 V03R03 and ANSI C63.10 2013.

Spectrum Analyzer settings:
RBW= 100 kHz
VBW= 300 kHz
Trace Mode= Peak Detector (Max Hold)
Sweep time= Auto
The in-built functionality of the Spectrum Analyzer is used to measure the 6-dB bandwidth.

       Limits:
The 6-dB bandwidth shall be at least 500 kHz

       Test Results:

    Frequency     Transmission     802.11    Data Rate     Bandwidth    Limit
                                                                                  Pass/Fail
      (MHz)          Chain         Mode       (Mbps)         (MHz)     (MHz)
       2412             A            b           1           10.12      > 0.5       Pass
       2437             A            b           1           10.12      > 0.5       Pass
       2462             A            b           1           10.12      > 0.5       Pass
       2472             A            b           1           10.09      > 0.5       Pass
       2412             A            g           6           16.36      > 0.5       Pass
       2437             A            g           6           16.37      > 0.5       Pass
       2462             A            g           6           16.37      > 0.5       Pass
       2472             A            g           6           16.37      > 0.5       Pass
       2412             A            n         MCS0          17.61      > 0.5       Pass
       2437             A            n         MCS0          17.62      > 0.5       Pass
       2462             A            n         MCS0          17.61      > 0.5       Pass
       2472             A            n         MCS0          17.63      > 0.5       Pass
                             Table 9-1. 6-dB Bandwidth Chain A




Report#: R‐TR190‐FCCIC‐WLAN‐1      Issued: September 15, 2015                      Page 15 of 151
                                     Microsoft EMC Laboratory


    Frequency    Transmission    802.11    Data Rate    Bandwidth     Limit
                                                                              Pass/Fail
      (MHz)         Chain        Mode       (Mbps)        (MHz)      (MHz)
       2412            B           b           1          10.12       > 0.5     Pass
       2437            B           b           1          10.12       > 0.5     Pass
       2462            B           b           1          10.12       > 0.5     Pass
       2472            B           b           1          10.10       > 0.5     Pass
       2412            B           g           6          16.36       > 0.5     Pass
       2437            B           g           6          16.37       > 0.5     Pass
       2462            B           g           6          16.37       > 0.5     Pass
       2472            B           g           6          16.36       > 0.5     Pass
       2412            B           n         MCS0         17.61       > 0.5     Pass
       2437            B           n         MCS0         17.61       > 0.5     Pass
       2462            B           n        MCS0             17.61    > 0.5     Pass
       2472            B           n        MCS0             17.62   > 0.5      Pass
                            Table 9-2. 6-dB Bandwidth Chain B




Report#: R‐TR190‐FCCIC‐WLAN‐1    Issued: September 15, 2015                   Page 16 of 151
                                  Microsoft EMC Laboratory


       Test Data:




                     Plot 9-1. 6dB Bandwidth 802.11b Chain A (Ch. 1)




                     Plot 9-2. 6dB Bandwidth 802.11b Chain A (Ch. 6)

Report#: R‐TR190‐FCCIC‐WLAN‐1   Issued: September 15, 2015             Page 17 of 151
                                  Microsoft EMC Laboratory


                    Plot 9-3. 6dB Bandwidth 802.11b Chain A (Ch. 11)




                    Plot 9-4. 6dB Bandwidth 802.11b Chain A (Ch. 13)

Report#: R‐TR190‐FCCIC‐WLAN‐1   Issued: September 15, 2015             Page 18 of 151
                                 Microsoft EMC Laboratory


                     Plot 9-5. 6dB Bandwidth 802.11g Chain A (Ch. 1)




                     Plot 9-6. 6dB Bandwidth 802.11g Chain A (Ch. 6)


Report#: R‐TR190‐FCCIC‐WLAN‐1   Issued: September 15, 2015             Page 19 of 151
                                  Microsoft EMC Laboratory


                    Plot 9-7. 6dB Bandwidth 802.11g Chain A (Ch. 11)




                    Plot 9-8. 6dB Bandwidth 802.11g Chain A (Ch. 13)


Report#: R‐TR190‐FCCIC‐WLAN‐1   Issued: September 15, 2015             Page 20 of 151
                                 Microsoft EMC Laboratory


                     Plot 9-9. 6dB Bandwidth 802.11n Chain A (Ch. 1)




                    Plot 9-10. 6dB Bandwidth 802.11n Chain A (Ch. 6)


Report#: R‐TR190‐FCCIC‐WLAN‐1   Issued: September 15, 2015             Page 21 of 151
                                  Microsoft EMC Laboratory


                    Plot 9-11. 6dB Bandwidth 802.11n Chain A (Ch. 11)




                    Plot 9-12. 6dB Bandwidth 802.11n Chain A (Ch. 13)


Report#: R‐TR190‐FCCIC‐WLAN‐1   Issued: September 15, 2015              Page 22 of 151
                                  Microsoft EMC Laboratory


                    Plot 9-13. 6dB Bandwidth 802.11b Chain B (Ch. 1)




                    Plot 9-34. 6dB Bandwidth 802.11b Chain B (Ch. 6)


Report#: R‐TR190‐FCCIC‐WLAN‐1   Issued: September 15, 2015             Page 23 of 151
                                 Microsoft EMC Laboratory


                    Plot 9-15. 6dB Bandwidth 802.11b Chain B (Ch. 11)




                    Plot 9-16. 6dB Bandwidth 802.11b Chain B (Ch. 13)


Report#: R‐TR190‐FCCIC‐WLAN‐1   Issued: September 15, 2015              Page 24 of 151
                                  Microsoft EMC Laboratory


                    Plot 9-47. 6dB Bandwidth 802.11g Chain B (Ch. 1)




                    Plot 9-18. 6dB Bandwidth 802.11g Chain B (Ch. 6)


Report#: R‐TR190‐FCCIC‐WLAN‐1   Issued: September 15, 2015             Page 25 of 151
                                 Microsoft EMC Laboratory


                    Plot 9-59. 6dB Bandwidth 802.11g Chain B (Ch. 11)




                    Plot 9-20. 6dB Bandwidth 802.11g Chain B (Ch. 13)


Report#: R‐TR190‐FCCIC‐WLAN‐1   Issued: September 15, 2015              Page 26 of 151
                                  Microsoft EMC Laboratory


                    Plot 9-21. 6dB Bandwidth 802.11n Chain B (Ch. 1)




                    Plot 9-22. 6dB Bandwidth 802.11b Chain B (Ch. 6)


Report#: R‐TR190‐FCCIC‐WLAN‐1   Issued: September 15, 2015             Page 27 of 151
                                 Microsoft EMC Laboratory


                    Plot 9-23. 6dB Bandwidth 802.11b Chain B (Ch. 11)




                    Plot 9-24. 6dB Bandwidth 802.11b Chain B (Ch. 13)


Report#: R‐TR190‐FCCIC‐WLAN‐1   Issued: September 15, 2015              Page 28 of 151
                                  Microsoft EMC Laboratory



Document Created: 2015-09-17 14:24:17
Document Modified: 2015-09-17 14:24:17

© 2024 FCC.report