Test Report

FCC ID: BRWSTX3

Test Report

Download: PDF
FCCID_4226851

                                             TEST REPORT
Reference No. ....................        : WTF19S01005314W V1

FCC ID ................................   : BRWSTX3

Applicant ............................    : Horizon Hobby, LLC

Address ..............................    : 2904 Research Rd. Champaign, Illinois 61821 United States

Manufacturer ....................         : The same as above.

Address ..............................    : The same as above.

Product Name ....................         : Transmitter

Model No. ...........................     : STX3

Standards ..........................      : FCC CFR47 Part 15 Section 15.249: 2016

Date of Receipt sample ....               : 2019-01-23

Date of Test .......................      : 2019-01-24 to 2019-02-20

Date of Issue ......................      : 2019-03-15
Test Result .........................     : Pass


Remarks:
The results shown in this test report refer only to the sample(s) tested, this test report cannot be
reproduced, except in full, without prior written permission of the company. The report would be invalid
without specific stamp of test institute and the signatures of compiler and approver.

                                              Prepared By:
                                 Waltek Services (Shenzhen) Co., Ltd.
    Address: 1/F., Fukangtai Building, West Baima Road, Songgang Street, Baoan District, Shenzhen,
                                           Guangdong, China
                                         Tel :+86-755-83551033
                                         Fax:+86-755-83552400
         Compiled by:                                                  Approved by:




         Ford Wang / Project Engineer                                  Philo Zhong / Manager




Waltek Services (Shenzhen) Co.,Ltd.
http://www.waltek.com.cn                                   Page 1 of 30


 Reference No.: WTF19S01005314W V1                  Page 2 of 30




                  2       Laboratories Introduction
Waltek Services (Shenzhen) Co., Ltd is a professional third-party testing and certification laboratory with
multi-year product testing and certification experience, established strictly in accordance with ISO/IEC 17025
requirements, and accredited by ILAC (International Laboratory Accreditation Cooperation) member. A2LA
(American Association for Laboratory Accreditation, the certification number is 4243.01) of USA, CNAS
(China National Accreditation Service for Conformity Assessment, the registration number is L3110) of China.
Meanwhile, Waltek has got recognition as registration and accreditation laboratory from EMSD (Electrical
and Mechanical Services Department), and American Energy star, FCC (The Federal Communications
Commission), CEC (California energy efficiency), ISED (Innovation, Science and Economic Development
Canada). It’s the strategic partner and data recognition laboratory of international authoritative organizations,
such as Intertek (ETL-SEMKO), TÜV Rheinland, TÜV SÜD, etc.




Waltek Services (Shenzhen) Co., Ltd is one of the largest and the most comprehensive third party testing
laboratory in China. Our test capability covered four large fields: safety test. Electro Magnetic Compatibility
(EMC), and energy performance, wireless radio. As a professional, comprehensive, justice international test
organization, we still keep the scientific and rigorous work attitude to help each client satisfy the international
standards and assist their product enter into globe market smoothly.




 Waltek Services (Shenzhen) Co.,Ltd.
 http://www.waltek.com.cn


 Reference No.: WTF19S01005314W V1             Page 3 of 30



Test Facility:


      A. Accreditations for Conformity Assessment (International)


        Country/Region        Scope Covered By             Scope                Note
        USA                                                FCC ID \ DOC \ VOC   1
        Canada                                             IC ID \ VOC          2
        Japan                                              MIC-T \ MIC-R        -
        Europe                                             EMCD \ RED           -
        Taiwan                                             NCC                  -
                              ISO/IEC 17025
        Hong Kong                                          OFCA                 -
        Australia                                          RCM                  -
        India                                              WPC                  -
        Thailand                                           NTC                  -
        Singapore                                          IDA                  -
        Note:
        1.   FCC Designation No.: CN1201. Test Firm Registration No.: 523476.
        2.   ISED CAB identifier: CN0013

      B. TCBs and Notify Bodies Recognized Testing Laboratory.


        Recognized Testing Laboratory of …                 Notify body number
        TUV Rheinland
        Intertek
                                                           Optional.
        TUV SUD
        SGS
        Phoenix Testlab GmbH                               0700
        Element Materials Technology Warwick Ltd           0891
        Timco Engineering, Inc.                            1177
        Eurofins Product Service GmbH                      0681




 Waltek Services (Shenzhen) Co.,Ltd.
 http://www.waltek.com.cn


Reference No.: WTF19S01005314W V1                                              Page 4 of 30




                          3          Contents
                                                                                                                                                                       Page
1      COVER PAGE ........................................................................................................................................... 1
2      LABORATORIES INTRODUCTION ................................................................................................................... 2
3      CONTENTS ............................................................................................................................................................ 4
4      REVISION HISTORY ............................................................................................................................................ 5
5      GENERAL INFORMATION.................................................................................................................................. 6
       5.1          GENERAL DESCRIPTION OF E.U.T. ............................................................................................................ 6
       5.2          DETAILS OF E.U.T. ..................................................................................................................................... 6
       5.3          TEST MODE ................................................................................................................................................ 6
6      TEST SUMMARY .................................................................................................................................................. 7
7      EQUIPMENT USED DURING TEST .................................................................................................................. 8
       7.1          EQUIPMENT LIST......................................................................................................................................... 8
       7.2          DESCRIPTION OF SUPPORT UNITS ........................................................................................................... 10
       7.3          MEASUREMENT UNCERTAINTY................................................................................................................. 10
       7.4          TEST EQUIPMENT CALIBRATION............................................................................................................... 10
8      RADIATION EMISSION TEST .......................................................................................................................... 11
       8.1          EUT OPERATION ...................................................................................................................................... 11
       8.2          TEST SETUP ............................................................................................................................................. 12
       8.3          SPECTRUM ANALYZER SETUP.................................................................................................................. 13
       8.4          TEST PROCEDURE .................................................................................................................................... 14
       8.5          TEST RESULT ........................................................................................................................................... 15
9      PERIODIC OPERATION .................................................................................................................................... 17
10     OUTSIDE OF BAND EMISSION ....................................................................................................................... 19
       10.1         TEST PROCEDURE .................................................................................................................................... 19
       10.2         TEST RESULT ........................................................................................................................................... 19
11     20 DB BANDWIDTH MEASUREMENT ........................................................................................................... 21
       11.1         TEST PROCEDURE .................................................................................................................................... 21
       11.2         TEST RESULT ........................................................................................................................................... 21
12     ANTENNA REQUIREMENT .............................................................................................................................. 23
13     PHOTOGRAPHS- STX3 TEST SETUP ........................................................................................................... 24
       13.1         RADIATION EMISSION ............................................................................................................................... 24
14     PHOTOGRAPHS - CONSTRUCTIONAL DETAILS ...................................................................................... 26
       14.1         MODEL STX3- EXTERNAL PHOTOS ......................................................................................................... 26
       14.2         MODEL STX3 - INTERNAL PHOTOS ......................................................................................................... 29




    Waltek Services (Shenzhen) Co.,Ltd.
    http://www.waltek.com.cn


 Reference No.: WTF19S01005314W V1             Page 5 of 30




4     Revision History


                   Date of
                                                 Date of
Test report No.    Receipt      Date of Test                  Purpose     Comment   Approved
                                                  Issue
                   sample

                                 2019-01-24
WTF19S01005
                  2019-01-23     to 2019-02-   2019-02-21      original      -      Replaced
    314W                              20

                                 2019-01-24
WTF19S01005
                  2019-01-23     to 2019-02-   2019-03-15     Version 1   Updated     Valid
314W V1                               20




 Waltek Services (Shenzhen) Co.,Ltd.
 http://www.waltek.com.cn


Reference No.: WTF19S01005314W V1                  Page 6 of 30



                  5       General Information
5.1    General Description of E.U.T.
      Product:                       Transmitter
      Model(s):                      STX3
      Model Description:             N/A
      Operation Frequency:           2405-2475MHz

      Hardware Version:              REVB

      Software Version:              REVD

      Highest frequency
                                     1.25GHz
      (Exclude Radio):

      Storage Location:              Internal Storage

      Note:                          N/A

5.2    Details of E.U.T.
       Ratings:                       DC4V-DC6V,<50mA for battery

5.3    Test Mode
      All test mode(s) and condition(s) mentioned were considered and evaluated respectively by
      performing full tests, the worst data were recorded and reported.

                      Test mode      Lower channel      Middle channel   Upper channel

                      Transmitting     2405MHz            2440MHz          2475MHz




Waltek Services (Shenzhen) Co.,Ltd.
http://www.waltek.com.cn


Reference No.: WTF19S01005314W V1     Page 7 of 30



               6     Test Summary
              Test Items                   Test Requirement   Result
        Conducted Emissions                     15.207         NA
                                               15.249(a)
          Radiated Emission                     15.209        PASS
                                               15.205(a)
           Periodic Operation                   15.35(c)      PASS
                                                15.249
      Outside of Band Emission                  15.205        PASS
                                                15.209
           20dB Bandwidth                      15:215(c)      PASS
         Antenna Requirement                    15.203        PASS




Waltek Services (Shenzhen) Co.,Ltd.
http://www.waltek.com.cn


       Reference No.: WTF19S01005314W V1              Page 8 of 30



       7       Equipment Used during Test
       7.1      Equipment List
Conducted Emissions Test Site 1#
                                                                                      Last
                                                                                                 Calibration
 Item            Equipment          Manufacturer     Model No.        Serial No.   Calibration
                                                                                                  Due Date
                                                                                      Date
  1.          EMI Test Receiver         R&S            ESCI            100947      2018-09-12    2019-09-11
  2.                LISN                R&S           ENV216           101215      2018-09-12    2019-09-11
  3.               Cable                Top         TYPE16(3.5M)          -        2018-09-12    2019-09-11
Conducted Emissions Test Site 2#
                                                                                      Last
                                                                                                 Calibration
 Item            Equipment          Manufacturer     Model No.        Serial No.   Calibration
                                                                                                  Due Date
                                                                                      Date
  1.          EMI Test Receiver         R&S            ESCI            101155      2018-09-12    2019-09-11
  2.                LISN           SCHWARZBECK       NSLK 8128        8128-289     2018-09-12    2019-09-11
                                                                     261115-001-
  3.               Limiter              York        MTS-IMP-136                    2018-09-12    2019-09-11
                                                                        0024
  4.               Cable              LARGE            RF300              -        2018-09-12    2019-09-11
3m Semi-anechoic Chamber for Radiation Emissions Test site 1#
                                                                                      Last
                                                                                                 Calibration
 Item            Equipment          Manufacturer     Model No.        Serial No.   Calibration
                                                                                                  Due Date
                                                                                      Date
  1          Spectrum Analyzer          R&S             FSP            100091      2018-04-29    2019-04-28
  2          Active Loop Antenna    Beijing Dazhi    ZN30900A             -        2018-04-09    2019-04-08
              Trilog Broadband
  3                                SCHWARZBECK       VULB9163            336       2018-04-09    2019-04-08
                   Antenna
                Coaxial Cable
  4                                     Top         TYPE16(13M)           -        2018-09-12    2019-09-11
                (below 1GHz)
              Broad-band Horn
  5                                SCHWARZBECK      BBHA 9120 D          667       2018-04-09    2019-04-08
                   Antenna
              Broad-band Horn
  6                                SCHWARZBECK       BBHA 9170           335       2018-04-09    2019-04-08
                   Antenna
                  Broadband        COMPLIANCE
  7                                                  PAP-1G18           2004       2018-04-13    2019-04-12
                  Preamplifier      DIRECTION
                Coaxial Cable
  8                                     Top         1GHz-25GHz       EW02014-7     2018-04-13    2019-04-12
                (above 1GHz)




        Waltek Services (Shenzhen) Co.,Ltd.
        http://www.waltek.com.cn


       Reference No.: WTF19S01005314W V1        Page 9 of 30



3m Semi-anechoic Chamber for Radiation Emissions Test site 2#
                                                                                Last
                                                                                           Calibration
 Item         Equipment          Manufacturer   Model No.       Serial No    Calibration
                                                                                            Due Date
                                                                                Date
  1         Test Receiver             R&S         ESCI           101296      2018-04-13    2019-04-12
           Trilog Broadband
  2                             SCHWARZBECK     VULB9160       9160-3325     2018-04-09    2019-04-08
                Antenna
                                 Compliance
  3             Amplifier         pirection     PAP-0203         22024       2018-04-13    2019-04-12
                                 systems inc
  4              Cable         HUBER+SUHNER       CBL2           525178      2018-04-13    2019-04-12
RF Conducted Testing
                                                                                Last
                                                                                           Calibration
 Item         Equipment          Manufacturer   Model No.       Serial No.   Calibration
                                                                                            Due Date
                                                                                Date
             EMC Analyzer
  1.                                 Agilent     E7405A        MY45114943    2018-09-12    2019-09-11
             (9k~26.5GHz)
           Spectrum Analyzer
  2.                                  R&S         FSL6           100959      2018-09-12    2019-09-11
               (9k-6GHz)
            Signal Analyzer
  3.                                 Agilent     N9010A        MY50520207    2018-09-12    2019-09-11
             (9k~26.5GHz)




       Waltek Services (Shenzhen) Co.,Ltd.
       http://www.waltek.com.cn


Reference No.: WTF19S01005314W V1              Page 10 of 30



7.2 Description of Support Units
            Equipment                   Manufacturer                       Model No.
                 /                             /                                /

7.3 Measurement Uncertainty
  Parameter                                Uncertainty
  Conducted Emission                     ± 3.64 dB(AC mains 150KHz~30MHz)
                                         ± 5.08 dB (Bilog antenna 30M~1000MHz)
  Radiated Spurious Emissions
                                         ± 5.47 dB (Horn antenna 1000M~25000MHz)
  Radio Frequency                        ± 1 x 10-7Hz
  RF Power                               ± 0.42 dB
  RF Power Density                       ± 0.7dB
  Conducted Spurious Emissions           ± 2.76 dB (9kHz~26500MHz)
  Confidence interval:95%. Confidence factor:k=2

7.4 Test Equipment Calibration
     All the test equipments used are valid and calibrated by CEPREI Certification Body that
     address is No.110 Dongguan Zhuang RD. Guangzhou, P.R.China.




 Waltek Services (Shenzhen) Co.,Ltd.
 http://www.waltek.com.cn


Reference No.: WTF19S01005314W V1                  Page 11 of 30



                  8     Radiation Emission Test
     Test Requirement:                 FCC Part15 Paragraph 15.249&15.209&15.205
     Test Method:                      ANSI 63.10: 2013
     Measurement Distance:             3m
     Test Result:                      PASS
     15.249(a)Limit:
        Fundamental frequency         Field strength of fundamental       Field strength of harmonics
                                            mV/m          dBuV/m            uV/m             dBuV/m
             902-928 MHz                     50             94              500                   54
          2400-2483.5 MHz                    50             94              500                   54
           5725-5875 MHz                     50             94              500                   54
           24.0-24.25 GHz                   250            108              2500                  68
     15.209 Limit:
                           Field Strength             Field Strength Limit at 3m Measurement Dist
      Frequency
                                       Distance
        (MHz)             uV/m                              uV/m                      dBuV/m
                                            (m)
    0.009 ~ 0.490      2400/F(kHz)          300     10000 * 2400/F(kHz)        20log(2400/F(kHz)) + 80
    0.490 ~ 1.705      24000/F(kHz)         30       100 * 24000/F(kHz)        20log(24000/F(kHz)) + 40
      1.705 ~ 30           30               30            100 * 30                 20log(30) + 40
       30 ~ 88             100              3                100                     20log(100)
       88 ~ 216            150              3                150                     20log(150)
      216 ~ 960            200              3                200                     20log(200)
      Above 960            500               3               500                     20log(500)
     Note: RF Voltage(dBuV)=20 log10 RF Voltage(uV)


8.1 EUT Operation

     Operating Environment :
     Temperature:                     23.5 °C
     Humidity:                        51.1 % RH
     Atmospheric Pressure:            101.2kPa
     EUT Operation :
     The test was performed in transmitting mode, the test data were shown in the report.




 Waltek Services (Shenzhen) Co.,Ltd.
 http://www.waltek.com.cn


Reference No.: WTF19S01005314W V1             Page 12 of 30


8.2 Test Setup
     The radiated emission tests were performed in the 3m Semi- Anechoic Chamber test site, using
     the setup accordance with the ANSI C63.10: 2013.
     The test setup for emission measurement below 30MHz.




               Semi-anechoic 3m Chamber
               Turn Table From 0°to 360°




                                                         3m
                              EUT


                            Turn Table
            0.8m




                                  PC              Spectrum            AMP          Combining
                                System            Analyzer                          Network


     The test setup for emission measurement from 30MHz to 1GHz.



             Semi-anechoic 3m Chamber
             Antenna Elevation Varies From 1 to 4 m
             Turn Table From 0°to 360°
                                                       3m


                             EUT


          0.8m             Turn Table




                                PC              Spectrum            AMP          Combining
                              System            Analyzer                          Network




 Waltek Services (Shenzhen) Co.,Ltd.
 http://www.waltek.com.cn


Reference No.: WTF19S01005314W V1                       Page 13 of 30



     The test setup for emission measurement above 1 GHz.



             Anechoic 3m Chamber
              Antenna Elevation Varies From 1 to 4 m
             Turn Table From 0°to 360°
                                                                   3m
                                EUT



          1.5m

                             Turn Table
                                                               Absorbers




                                   PC                      Spectrum                    AMP     Combining
                                 System                    Analyzer                             Network



8.3 Spectrum Analyzer Setup


          Below 30MHz
                         Sweep Speed .............................................. Auto
                         IF Bandwidth ................................................ 10kHz
                         Video Bandwidth ......................................... 10kHz
                         Resolution Bandwidth ................................. 10kHz
          30MHz ~ 1GHz
                         Sweep Speed .............................................. Auto
                         Detector ....................................................... PK
                         Resolution Bandwidth.................................. 100kHz
                         Video Bandwidth ......................................... 300kHz
          Above 1GHz
                         Sweep Speed .............................................. Auto
                         Detector ..................................................... PK
                         Resolution Bandwidth.................................. 1MHz
                         Video Bandwidth ......................................... 3MHz
                         Detector ..................................................... Ave.
                         Resolution Bandwidth.................................. 1MHz
                         Video Bandwidth ......................................... 10Hz




 Waltek Services (Shenzhen) Co.,Ltd.
 http://www.waltek.com.cn


Reference No.: WTF19S01005314W V1                Page 14 of 30



8.4 Test Procedure

     1. The EUT is placed on a turntable. For below 1GHz, the EUT is 0.8m above ground plane;
     For above1GHz, the EUT is 1.5m above ground plane.
     2. The turntable shall be rotated for 360 degrees to determine the position of maximum emission
     level.
     3. EUT is set 3m away from the receiving antenna, which is moved from 1m to 4m to find out the
     maximum emissions. The spectrum was investigated from the lowest radio frequency signal
     generated in the device, without going below 9 kHz, up to the tenth harmonic of the highest
     fundamental frequency or to 40 GHz, whichever is lower.
     4. Maximum procedure was performed on the six highest emissions to ensure EUT compliance.
     5. And also, each emission was to be maximized by changing the polarization of receiving antenna
     both horizontal and vertical.
     6. Repeat above procedures until the measurements for all frequencies are complete.
     7. The radiation measurements are tested under 3-axes(X,Y,Z) position(X denotes lying on the
     table, Y denotes side stand and Z denotes vertical stand), After pre-test, It was found that the
     worse radiation emission was get at the X position. So the data shown was the X position only.
     8. New battery is used during test.




 Waltek Services (Shenzhen) Co.,Ltd.
 http://www.waltek.com.cn


Reference No.: WTF19S01005314W V1                 Page 15 of 30


8.5     Test Result

       Test Frequency :16MHz~ 30MHz
       The measurements were more than 20 dB below the limit and not reported.
       Test Frequency: 30MHz ~ 18GHz
       Test Mode:The Worst mode(Low channel Transmitting) data is recorded on the report


                Receiv                         RX                                    FCC Part
                                   Turn      Antenna                  Correct     15.231/209/205
      Frequen     er     Detect                            Correcte
                                   table                                ed
         cy     Readi      or               Hei     Pol    d Factor
                                   Angle                              Amplit     Limit    Margin
                 ng                         ght     ar                 ude
                         (PK/QP    Degre             (H/              (dBμV/     (dBμV/
       (MHz)    (dBμV)                      (m)            (dB/m)                          (dB)
                          /Ave)      e                V)                m)         m)

      2405.00   91.19      PK       349     1.9      H      -13.08     78.11     114.00   -35.89

      2405.00   95.47      PK       281     1.8      V      -13.08     82.39     114.00   -31.61

      4810.00   50.21      PK       151     1.7      H       0.09      50.30     74.00    -23.70

      4810.00   52.31      PK        11     1.1      V       0.09      52.40     74.00    -21.60

      7215.00   45.21      PK       176     1.1      H       3.01      48.22     74.00    -25.78

      7215.00   43.26      PK        64     1.9      V       3.01      46.27     74.00    -27.73

      9620.00   41.52      PK        67     1.6      H       5.39      46.91     74.00    -27.09

      9620.00   39.62      PK       125     1.7      V       5.39      45.01     74.00    -28.99

       12025    36.25      PK       323     1.4      H       8.15      44.40     74.00    -29.60

       12025    35.21      PK       295     1.5      V       8.15      43.36     74.00    -30.64

       14430    32.12      PK        74     1.2      H      10.02      42.14     74.00    -31.86

       14430    32.14      PK       267     1.5      V      10.02      42.16     74.00    -31.84




 Waltek Services (Shenzhen) Co.,Ltd.
 http://www.waltek.com.cn


Reference No.: WTF19S01005314W V1              Page 16 of 30



   AV = Peak +20Log10(duty cycle) =Peak+(-4.25)[refer to section 7 for more detail]
                                                                                         FCC Part
                         Turn           RX Antenna         Duty                       15.231/209/205
Frequency      PK        table                            cycle        AV
                         Angle        Height    Polar     Factor                  Limit        Margin

            (dBμV/m                                                 (dBμV/m     (dBμV/m
  (MHz)                 Degree         (m)      (H/V)      (dB)                                 (dB)
               )                                                       )           )

 2405.00      78.11       349          1.9        H        -4.25      73.86       94.00        -20.14

 2405.00      82.39       281          1.8        V        -4.25      78.14       94.00        -15.86

 4810.00      50.30       151          1.7        H        -4.25      46.05       54.00         -7.95

 4810.00      52.40        11          1.1        V        -4.25      48.15       54.00         -5.85

 7215.00      48.22       176          1.1        H        -4.25      43.97       54.00        -10.03

 7215.00      46.27        64          1.9        V        -4.25      42.02       54.00        -11.98

 9620.00      46.91        67          1.6        H        -4.25      42.66       54.00        -11.34

 9620.00      45.01       125          1.7        V        -4.25      40.76       54.00        -13.24

  12025       44.40       323          1.4        H        -4.25      40.15       54.00        -13.85

  12025       43.36       295          1.5        V        -4.25      39.11       54.00        -14.89

  14430       42.14        74          1.2        H        -4.25      37.89       54.00        -16.11

  14430       42.16       267          1.5        V        -4.25      37.91       54.00        -16.09


    Test Frequency :From 18GHz to 25GHz
    The measurements were more than 20 dB below the limit and not reported.




Waltek Services (Shenzhen) Co.,Ltd.
http://www.waltek.com.cn


  Reference No.: WTF19S01005314W V1                Page 17 of 30



 9     Periodic Operation
       The duty cycle was determined by the following equation:
       To calculate the actual field intensity,the duty cycle correction factor in decibel is needed for later
       use and can be obtained from following conversion


       Duty Cycle(%)=Total On interval in a complete pulse train/ Length of a complete pulse train * %
       Duty Cycle Correction Factor(dB)=20 * Log10(Duty Cycle)


               Test Channel                          Low Channel          Middle Channel         High Channel
        Total transmission time(ms)                     22.80                23.20                 22.80

Length of a complete transmission period(ms)            37.20                37.20                 37.20

               Duty Cycle(%)                            61.29                62.37                 61.29

      Duty Cycle Correction Factor(dB)                  -4.25                 -4.10                 -4.25


       Refer to the duty cycle plot (as below)

                                                  Test plots
                                                 Low Channel




  Waltek Services (Shenzhen) Co.,Ltd.
  http://www.waltek.com.cn


Reference No.: WTF19S01005314W V1        Page 18 of 30



                                      Middle Channel




                                      High Channel




Waltek Services (Shenzhen) Co.,Ltd.
http://www.waltek.com.cn


Reference No.: WTF19S01005314W V1                   Page 19 of 30



10 Outside of Band Emission
    Test Requirement:                     15.249(d):Emissions radiated outside of the specified frequency
                                          bands, except for harmonics, shall be attenuated by at least 50 dB
                                          below the level of the fundamental or to the general radiated
                                          emission limits in §15.209, whichever is the lesser attenuation.
     Test Method:                         ANSI C63.10:2013
     Test Mode:                           Transmitting


10.1 Test Procedure

        Refer to section 7.4 of this test report.


10.2 Test Result



                                                      Test plots

                                                      Left band




 Waltek Services (Shenzhen) Co.,Ltd.
 http://www.waltek.com.cn


Reference No.: WTF19S01005314W V1     Page 20 of 30



                                      Right band




Waltek Services (Shenzhen) Co.,Ltd.
http://www.waltek.com.cn


Reference No.: WTF19S01005314W V1            Page 21 of 30



11 20 dB Bandwidth Measurement
     Test Requirement:                      FCC CFR47 Part 15 Section 15.215(c)
     Test Method:                           ANSI C63.10:2013
     Test Mode:                            Transmitting
11.1 Test Procedure

     1. Remove the antenna from the EUT and then connect a low RF cable from the antenna port to the
       spectrum;
     2. Set the spectrum analyzer: RBW = 100kHz, VBW = 300kHz
11.2 Test Result

            Test Channel                 20dB Bandwidth                 99% Bandwidth
                   low                      0.408MHz                              /
                Middle                      0.390MHz                              /
                   high                     0.396MHz                              /

                                            Test plots
                                            Low Channel




 Waltek Services (Shenzhen) Co.,Ltd.
 http://www.waltek.com.cn


Reference No.: WTF19S01005314W V1      Page 22 of 30




                                      Middle Channel




                                      High Channel




Waltek Services (Shenzhen) Co.,Ltd.
http://www.waltek.com.cn


 Reference No.: WTF19S01005314W V1                Page 23 of 30



12 Antenna Requirement
Requirement

FCC CFR Title 47 Part 15 Subpart C Section 15.203:
An intentional radiator shall be designed to ensure that no antenna other than that furnished by the
responsible party shall be used with the device. The use of a permanently attached antenna or of
anantenna that uses a unique coupling to the intentional radiator, the manufacturer may design the unit so
that a broken antenna can be replaced by the user, but the use of a standard antenna jack or electrical
connector is prohibited.

Refer to statement below for compliance.
The manufacturer may design the unit so that the user can replace a broken antenna, but the use of a
standard antenna jack or electrical connector is prohibited. Further, this requirement does not apply to
intentional radiators that must be professionally installed.
TEST RESULTS
fulfil the requirement of this section.

                                          ANT




 Waltek Services (Shenzhen) Co.,Ltd.
 http://www.waltek.com.cn


Reference No.: WTF19S01005314W V1             Page 24 of 30



13 Photographs- STX3 Test Setup
13.1 Radiation Emission
                              Test frequency Below 30MHz at test site 2#




                          Test frequency from 30MHz to 1GHz at test site 2#




 Waltek Services (Shenzhen) Co.,Ltd.
 http://www.waltek.com.cn


Reference No.: WTF19S01005314W V1           Page 25 of 30




                             Test frequency above 1GHz at test site 1#




Waltek Services (Shenzhen) Co.,Ltd.
http://www.waltek.com.cn


Reference No.: WTF19S01005314W V1      Page 26 of 30



14 Photographs - Constructional Details
14.1   Model STX3- External Photos




 Waltek Services (Shenzhen) Co.,Ltd.
 http://www.waltek.com.cn




Reference No.: WTF19S01005314W V1     Page 28 of 30




Waltek Services (Shenzhen) Co.,Ltd.
http://www.waltek.com.cn


Reference No.: WTF19S01005314W V1      Page 29 of 30


14.2   Model STX3 - Internal Photos




               ANT




 Waltek Services (Shenzhen) Co.,Ltd.
 http://www.waltek.com.cn


Reference No.: WTF19S01005314W V1             Page 30 of 30




                                      ======End of Report======




Waltek Services (Shenzhen) Co.,Ltd.
http://www.waltek.com.cn



Document Created: 2019-04-07 07:56:23
Document Modified: 2019-04-07 07:56:23

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC