RF Exposure evaluation

FCC ID: BRWMR210

RF Exposure Info

Download: PDF
FCCID_4045941

                         SAR Evaluation for extremity conditions
1.   Extremity exposure conditions
     Devices that are designed or intended for use on extremities or mainly operated in extremity only exposure
     conditions; i.e., hands, wrists, feet and ankles, may require extremity SAR evaluation. When the device also
     operates in close proximity to the user’s body, SAR compliance for the body is also required. The 1-g body and
     10-g extremity SAR Test Exclusion Thresholds should be applied to determine SAR test requirements.
2.   Standalone SAR test exclusion considerations
     For FCC:
     1)   The 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances ≤ 50 mm
          are determined by:

          [(max. power of channel, including tune-up tolerance, mW) / (min. test separation distance, mm)] ·   f (GHz )
          ≤ 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR, where
         f (GHz) is the RF channel transmit frequency in GHz
         Power and distance are rounded to the nearest mW and mm before calculation
         The result is rounded to one decimal place for comparison
         3.0 and 7.5 are referred to as the numeric thresholds in the step 2 below
          The test exclusions are applicable only when the minimum test separation distance ≤ 50 mm and for
          transmission frequencies between 100 MHz and 6 GHz
     2)   At 100 MHz to 6 GHz and for test separation distances > 50 mm, the SAR test exclusion threshold is
          determined according to the following, and as illustrated in Appendix B of KDB 447498
         [Power allowed at numeric threshold for 50 mm in step 1) + (test separation distance - 50 mm)·(f(MHz)/150)]
          mW, at 100 MHz to 1500 MHz
         [Power allowed at numeric threshold for 50 mm in step 1) + (test separation distance – 50 mm)·10] mW at >
          1500 MHz and ≤ 6 GHz


3.   UT Description (worst case)




                               Distance of antenna to extremity exposure positions(mm)
                                   Top button                              27


     For FCC:
                                                 Conducted Power of EUT
     Frequency      Power        Power       Tune-up power     Tune-up power     Test distances      Limit
       (MHz)        (dBm)        (mW)            (dBm)             (mW)              (mm)         (10-g SAR)
       2405          18.15       65.31             18.50           70.79                 27          4.07



           (70.79X√2.405 )/27 =4.07 <7.5




4.   Conclusion
     SAR test for 10-g extremity is exclusion.



Document Created: 2018-10-23 16:33:35