                          Product Name : Surface Radio
                          Model No.              : DX2E
                          FCC ID                 : BRWDSTX1
                          IC                     : 6157A-STX1




                Applicant : Horizon Hobby, Inc.
                Address : 4105 Fieldstone Rd.Champaign, IL 61822




                       Date of Receipt : 28/08/2012
                       Issued Date              : 23/11/2012
                       Report No.               : 128S067R-RF-US-P20V01
                       Report Version : V2.0




The test results relate only to the samples tested.
The test results shown in the test report are traceable to the national/international standard through the calibration
of the equipment and evaluated measurement uncertainty herein.
This report must not be used to claim product endorsement by TAF, CNAS or any agency of the Government.
The test report shall not be reproduced except in full without the written approval of QuieTek Corporation.


                                                      Report No: 128S067R-RF-US-P20V01



                Tes t R ep or t Cer t if ic at i on
                                                Issued Date : 23/11/2012
                                                Report No. : 128S067R-RF-US-P20V01




Product Name          :   Surface Radio
Applicant             :   Horizon Hobby, Inc.
Address               :   4105 Fieldstone Rd.Champaign, IL 61822
Manufacturer          :   Horizon Hobby, Inc.
Address               :   4105 Fieldstone Rd.Champaign, IL 61822
Model No.             :   DX2E
FCC ID                :   BRWDSTX1
IC                    :   6157A-STX1
EUT Voltage           :   6V
Brand Name            :   Spektrum
Applicable Standard   :   FCC OET 65
                          RSS-102: Issue 4, March, 2010
Test Result           :   Complied
Performed Location    :   Suzhou EMC Laboratory
                          No.99 Hongye Rd., Suzhou Industrial Park Loufeng
                          Hi-Tech Development Zone., Suzhou, China
                          TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098
                          FCC Registration Number: 800392; IC Lab Code: 4075B


Documented By         :
                                  (Engineering ADM: Alice Ni)

Reviewed By           :
                                 (Senior Engineer: Jame Yuan)

Approved By           :
                                     (Manager: Marlin Chen)




                                 Page: 2 of 5


                                                                   Report No: 128S067R-RF-US-P20V01



Laboratory Information


We, QuieTek Corporation, are an independent EMC and safety consultancy that was
established the whole facility in our laboratories. The test facility has been
accredited/accepted(audited or listed) by the following related bodies in compliance with ISO
17025, EN 45001 and specified testing scope:


 Taiwan R.O.C.          :   BSMI, NCC, TAF
 Germany                :   TUV Rheinland
 Norway                 :   Nemko, DNV
 USA                    :   FCC, NVLAP
 Japan                  :   VCCI
 China                  :   CNAS

The related certificate for our laboratories about the test site and management system can be downloaded
from QuieTek Corporation’s Web Site :http://www.quietek.com/tw/ctg/cts/accreditations.htm
The address and introduction of QuieTek Corporation’s laboratories can be founded in our Web site :
http://www.quietek.com/
If you have any comments, Please don’t hesitate to contact us. Our contact information is as below:

 HsinChu Testing Laboratory :
 No.75-2, 3rd Lin, Wangye Keng, Yonghxing Tsuen, Qionglin Shiang, Hsinchu County 307, Taiwan, R.O.C.
 TEL:+886-3-592-8858 / FAX:+886-3-592-8859              E-Mail : service@quietek.com

 LinKou Testing Laboratory :
 No.5-22, Ruishukeng, Linkou Dist., New Taipei City 24451, Taiwan, R.O.C.
 TEL : 886-2-8601-3788 / FAX : 886-2-8601-3789            E-Mail : service@quietek.com


 Suzhou Testing Laboratory :
 No.99 Hongye Rd., Suzhou Industrial Park Loufeng Hi-Tech Development Zone., SuZhou, China
 TEL : +86-512-6251-5088 / FAX : 86-512-6251-5098 E-Mail : service@quietek.com




                                             Page: 3 of 5


                                                              Report No: 128S067R-RF-US-P20V01


1. RF Exposure Evaluation

1.1. Limits

    According to FCC 1.1310: The criteria listed in the following table shall be used to evaluate
    the environment impact of human exposure to radio frequency (RF) radiation as specified in
    1.1307(b)
    LIMITS FOR MAXIMUM PERMISSIBLE EXPOSURE (MPE)
                              Electric           Magnetic
                                                                   Power             Average
          Frequency           Field              Field
                                                                   Density           Time
          Range (MHz)         Strength           Strength
                                                                   (mW/cm2)          (Minutes)
                              (V/m)              (A/m)
          (A) Limits for Occupational/ Control Exposures
          300-1500            --                 --                F/300             6
          1500-100,000        --                 --                5                 6
          (B) Limits for General Population/ Uncontrolled Exposures
          300-1500            --                 --                F/1500            6
          1500-100,000        --                 --                1                 30
    F= Frequency in MHz


    Friis Formula
    Friis transmission formula: Pd = (Pout*G)/(4*pi*r2)


    Where
    Pd = power density in mW/cm2
    Pout = output power to antenna in mW
    G = gain of antenna in linear scale
    Pi = 3.1416
    R = distance between observation point and center of the radiator in cm


    Pd id the limit of MPE, 1 mW/cm2 . If we know the maximum gain of the antenna and the total
    power input to the antenna, through the calculation, we will know the distance r where the
    MPE limit is reached.




                                          Page: 4 of 5


                                                                Report No: 128S067R-RF-US-P20V01


1.2. Test Procedure

        Software provided by client enabled the EUT to transmit and receive data at lowest, middle
        and highest channel individually.
        The temperature and related humidity: 18℃and 78% RH.


1.3. Test Result of RF Exposure Evaluation

        Product          :   Surface Radio
        Test Item        :   RF Exposure Evaluation
        Test Site        :   AC-6


Antenna Gain:
Antenna Gain: The maximum Gain measured in fully anechoic chamber is 2dBi in logarithm scale.


Output Power into Antenna & RF Exposure Evaluation Distance:

                                Maximum Output Power to      Power Density at R = 20 cm
  Frequency Band (MHz)
                                      Antenna (mW)                    (mW/cm2)

        2418~2460MHz                        73.6207                    0.023213


Note:
The power density Pd (4th column) at a distance of 20 cm calculated from the Friis transmission
formula is far below the limit of 1 mW/cm2.