Test Report

FCC ID: BRWBLH9012

Test Report

Download: PDF
FCCID_2919119

        CENTRE OF TESTING SERVICE
             INTERNATIONAL

      OPERATE ACCORDING TO ISO/IEC 17025




     FCC ID/IC
   TEST REPORT
TEST REPORT NUMBER : CGZ3160104-00004-EFI




                  CENTRE OF TESTING SERVICE CO., LTD.
        A101,No.65,Zhuji Highway,Tianhe District,Guangzhou, China


       FCC ID:BRWBLH9012
       IC:6157A-BLH9012




                                                                          TEST REPORT For FCC ID/IC

                                                       47 CFR PART 15 OCT, 2015; RSS-210 Issue 8
               Report Reference No. ..................... CGZ3160104-00004-EFI
               Date of issue ..................................... 11 January 2016
               Testing Laboratory Name ............... CENTRE OF TESTING SERVICE CO., LTD.
               Address ............................................. A101,No.65,Zhuji Highway,Tianhe District,Guangzhou, China
               Testing location/ procedure ............... Full application of Harmonised standards ■
                                                                             Partial application of Harmonised standards □
                                                                             Other standard testing method □
               Applicant’s name............................. Horizon Hobby, LLC
               Address ............................................. 4105 Fieldstone Road, Champaign, IL 61822, USA
               Test specification ............................
               Standard ............................................ 47 CFR PART 15 OCT, 2015; RSS-210 Issue 8; RSS-Gen Issue 4
                                                                             ANSI C63.10:2013
               Test Report Form No. ..................... CTSEMC-1.0
               TRF Originator................................... CENTRE OF TESTING SERVICE CO., LTD.
               Master TRF........................................ Dated 2009-01
               CENTRE OF TESTING SERVICE CO., LTD. All rights reserved.
               This publication may be reproduced in whole or in part for non-commercial purposes as long as the
               CENTRE OF TESTING SERVICE CO., LTD is acknowledged as copyright owner and source of the
               material. CENTRE OF TESTING SERVICE CO., LTD takes no responsibility for and will not assume liability
               for damages resulting from the reader's interpretation of the reproduced material due to its placement and
               context.
               Test item description .....................:Blade Inductrix 200 Quadcopter
               Trade Mark ....................................... Blade
               Manufacturer .................................... Horizon Hobby, LLC
               Model/Type reference ...................... BLH9080
               Ratings ............................................. Battery 11.1V
               Operating Frequency......................... 2404.0MHz ~2476.0MHz
               Result ............................................... Positive

                           Compiled by:                                                     Supervised by:                                                   Approved by:



                  Kate zhang / Fileadministrators                                   Duke yang / Technique principal                                        Vincent yao / Manager




Copyright of this report is owned by Centre of Testing Service and may not be reproduced other than in full except with the written approval of the issuing Company.


CENTRE OF TESTING SERVICE CO., LTD.
A101,No.65,Zhuji Highway,Tianhe District,Guangzhou, China
Tel:+86-20-85543113 (32 lines)                 Fax:+86-20-38780406
Complaint line:+86-20-85533471                 E-mail:cts@cts-lab.com.cn                         See Reverse For Terms And Conditions of Service


Report No.: CGZ3160104-00004-EFI                                                                                                                                       Page 1 of 32


       FCC ID:BRWBLH9012
       IC:6157A-BLH9012




                                            FCC ID/IC -- T E S T R E P O R T
                                                                                                                                                      11 January 2016
        Test Report No. :                                     CGZ3160104-00004-EFI                                                                     Date of issue


        Type / Model............................                BLH9080

        EUT..........................................           Blade Inductrix 200 Quadcopter

        Applicant………………………                                      Horizon Hobby, LLC
        Address....................................             4105 Fieldstone Road, Champaign, IL 61822, USA
        Telephone................................               +1-217 4033657
        Fax...........................................          /
        Contact.....................................            Erin Hassan

        Manufacturer………………….                                    Horizon Hobby, LLC
        Address....................................             4105 Fieldstone Road, Champaign, IL 61822, USA
        Telephone................................               +1-217 4033657
        Fax...........................................          /
        Contact.....................................            Erin Hassan

        Factory…………....................... Yeeunc International Co., Ltd.
        Address.................................... /
        Telephone................................ /
        Fax............................................ /
        Contact..................................... /


        Test Result according to the standards on page 1: PASSED
          The test report merely corresponds to the test sample.
          It is not permitted to copy extracts of these test result without the written permission of the test laboratory.




Copyright of this report is owned by Centre of Testing Service and may not be reproduced other than in full except with the written approval of the issuing Company.


CENTRE OF TESTING SERVICE CO., LTD.
A101,No.65,Zhuji Highway,Tianhe District,Guangzhou, China
Tel:+86-20-85543113 (32 lines)                 Fax:+86-20-38780406
Complaint line:+86-20-85533471                 E-mail:cts@cts-lab.com.cn                         See Reverse For Terms And Conditions of Service


Report No.: CGZ3160104-00004-EFI                                                                                                                                       Page 2 of 32


       FCC ID:BRWBLH9012
       IC:6157A-BLH9012




                                                                    TABLE OF CONTENTS
Description                                                                                                                                                                    Page

1.TEST STANDARDS........................................................................................................................................5


2.SUMMARY......................................................................................................................................................5

     2.1 GENERAL REMARKS .......................................................................................................................................5
     2.2 FINAL ASSESSMENT........................................................................................................................................5

3.EQUIPMENT UNDER TEST ...........................................................................................................................5

     3.1 POWER SUPPLY SYSTEM UTILISED..........................................................................................................................5
     3.2 SHORT DESCRIPTION OF THE EQUIPMENT UNDER TEST (EUT).................................................................................5
     3.3 EUT OPERATION MODE .........................................................................................................................................5
     3.4 EUT CONFIGURATION............................................................................................................................................6

4.TEST ENVIRONMENT....................................................................................................................................7

     4.1 ADDRESS OF THE TEST LABORATORY.....................................................................................................................7
     4.2 TEST FACILITY ......................................................................................................................................................7
     4.3 ENVIRONMENTAL CONDITIONS ...............................................................................................................................7
     4.4 DEFINITIONS OF SYMBOLS USED IN THIS TEST REPORT ............................................................................................7
     4.5 STATEMENT OF THE MEASUREMENT UNCERTAINTY .................................................................................................7
     4.6 MEASUREMENT UNCERTAINTY ...............................................................................................................................8

5.SUMMARY OF STANDARDS AND RESULTS...............................................................................................8

     5.1.DESCRIPTION OF STANDARDS AND RESULTS .........................................................................................................8

6.POWER LINE CONDUCTED EMISSION TEST .............................................................................................9

     6.1.TEST EQUIPMENT..................................................................................................................................................9
     6.2. BLOCK DIAGRAM OF TEST SETUP .........................................................................................................................9
     6.3. POWER LINE CONDUCTED EMISSION TEST LIMITS .................................................................................................9
     6.4.TEST PROCEDURE ................................................................................................................................................9
     6.5. POWER LINE CONDUCTED EMISSION TEST RESULTS .............................................................................................9

7.RADIATED DISTURBANCE (ELECTRIC FIELD) ........................................................................................10

     7.1.TEST EQUIPMENT................................................................................................................................................10
     7.2.BLOCK DIAGRAM OF TEST SETUP .......................................................................................................................10
     7.3.RADIATED EMISSION LIMIT : ................................................................................................................................11
     7.4.TEST PROCEDURE ..............................................................................................................................................12
     7.5.RADIATED EMISSION TEST RESULTS ...................................................................................................................12

8.BAND EDGE COMPLIANCE TEST..............................................................................................................24

     8.1. TEST EQUIPMENT ...............................................................................................................................................24
     8.2. TEST INFORMATION ............................................................................................................................................24
Copyright of this report is owned by Centre of Testing Service and may not be reproduced other than in full except with the written approval of the issuing Company.


CENTRE OF TESTING SERVICE CO., LTD.
A101,No.65,Zhuji Highway,Tianhe District,Guangzhou, China
Tel:+86-20-85543113 (32 lines)                 Fax:+86-20-38780406
Complaint line:+86-20-85533471                 E-mail:cts@cts-lab.com.cn                         See Reverse For Terms And Conditions of Service


Report No.: CGZ3160104-00004-EFI                                                                                                                                       Page 3 of 32


       FCC ID:BRWBLH9012
       IC:6157A-BLH9012


     8.3. TEST PROCEDURE ..............................................................................................................................................24
     8.4. TEST RESULTS ..................................................................................................................................................24

9. 99% BANDWIDTH .......................................................................................................................................29

     9.1 TEST PROCEDURE ...............................................................................................................................................29
     9.2. TEST EQUIPMENT ...............................................................................................................................................29
     9.3. TEST RESULTS ..................................................................................................................................................29

10. DEVIATION TO TEST SPECIFICATIONS .................................................................................................32




Copyright of this report is owned by Centre of Testing Service and may not be reproduced other than in full except with the written approval of the issuing Company.


CENTRE OF TESTING SERVICE CO., LTD.
A101,No.65,Zhuji Highway,Tianhe District,Guangzhou, China
Tel:+86-20-85543113 (32 lines)                 Fax:+86-20-38780406
Complaint line:+86-20-85533471                 E-mail:cts@cts-lab.com.cn                         See Reverse For Terms And Conditions of Service


Report No.: CGZ3160104-00004-EFI                                                                                                                                       Page 4 of 32


       FCC ID:BRWBLH9012
       IC:6157A-BLH9012




1.TEST STANDARDS
           The tests were performed according to following standards:

           ■47 CFR PART 15 OCT, 2015
           ■ RSS-210 Issue 8
           ■ RSS-Gen Issue 4
           ■ ANSI C63.10:2013

2.SUMMARY
     2.1 GENERAL REMARKS
              Date of receipt of test sample                          04 January 2016

              Testing commenced on                                    04~11 January 2016

              Testing concluded on                                    11 January 2016
     2.2 FINAL ASSESSMENT
           The FCC/IC requirements pertaining to the technical standards and tested operation modes are

          ■        - fulfilled.
          □        - not fulfilled.
          The equipment under test
          ■        - fulfils the FCC/IC requirements cited on page 1.
          □        - does not fulfil the FCC/IC requirements cited on page 1.

3.EQUIPMENT UNDER TEST
     3.1 Power supply system utilised
            Power supply voltage                     :               ■ Battery 11.1V


     3.2 Short description of the Equipment under Test (EUT)
     Number of tested samples: 1
     Serial number:            Prototype
     3.3 EUT operation mode
     The equipment under test was operated during the measurement under the following conditions:
     □ TX- Y position
     □ TX- Zposition
     ■ TX- X position

      Operation mode 1:TX-X Position Low (2404MHz) , TX-X Position Middle (2440MHz ),
                        TX-X Position High (2476MHz)
     Note:Operation mode 1 TX -X position of EUT is the radiated test worst case; so only these test results be
     recorded in the test report.



Copyright of this report is owned by Centre of Testing Service and may not be reproduced other than in full except with the written approval of the issuing Company.


CENTRE OF TESTING SERVICE CO., LTD.
A101,No.65,Zhuji Highway,Tianhe District,Guangzhou, China
Tel:+86-20-85543113 (32 lines)                 Fax:+86-20-38780406
Complaint line:+86-20-85533471                 E-mail:cts@cts-lab.com.cn                         See Reverse For Terms And Conditions of Service


Report No.: CGZ3160104-00004-EFI                                                                                                                                       Page 5 of 32


       FCC ID:BRWBLH9012
       IC:6157A-BLH9012




     3.4 EUT configuration
             3.4.1. Description of configuration (EUT)

                             Description                                       :        Blade Inductrix 200 Quadcopter
                             Model Number                                      :        BLH9080
                             Operation frequency                               :        2404~ 2476 MHz ISM Band
                             Modulation Technology                             :        DSSS Modulation
                             Antenna                                           :        Internal antenna, met requirement of FCC 15.203

             3.4.2. Tested Supporting System Details
                     N/A




Copyright of this report is owned by Centre of Testing Service and may not be reproduced other than in full except with the written approval of the issuing Company.


CENTRE OF TESTING SERVICE CO., LTD.
A101,No.65,Zhuji Highway,Tianhe District,Guangzhou, China
Tel:+86-20-85543113 (32 lines)                 Fax:+86-20-38780406
Complaint line:+86-20-85533471                 E-mail:cts@cts-lab.com.cn                         See Reverse For Terms And Conditions of Service


Report No.: CGZ3160104-00004-EFI                                                                                                                                       Page 6 of 32


       FCC ID:BRWBLH9012
       IC:6157A-BLH9012




4.TEST ENVIRONMENT

     4.1 Address of the test laboratory
     A101,No.65,Zhuji Highway,Tianhe District,Guangzhou, China

     Tel:+86-20-85543113                        (32 lines)                         Fax:+86-20-38780406

     4.2 Test facility
     The test facility is recognized, certified, or accredited by the following organizations:
    CNAS-Lab Code: L3394
     CENTRE OF TESTING SERVICE CO., LTD has been assessed and proved to be in
     compliance with CNAS-CL01: 2006 Accreditation Criteria for Testing and Calibration
     Laboratories (identical to ISO/IEC 17025: 2005 General Requirements) for the Competence of
     Testing and Calibration Laboratories.
    IC-Registration No.: 8374A
    The 3m Alternate Test Site of CENTRE OF TESTING SERVICE CO., LTD has been registered by Certification
    and Engineering Bureau of Industry Canada for the performance of radiated measurements with Registration No.
    8374A on June 6, 2011.
    FCC-Registration No.: 971995
     CENTRE OF TESTING SERVICE CO., LTD, EMC Laboratory has been registered
     and fully described in a report filed with the FCC (Federal Communications Commission). The
     acceptance letter from the FCC is maintained in our files. Registration No.791995, July 13,2012.

     4.3 Environmental conditions
     During the measurement the environmental conditions were within the listed ranges:
                    Temperature:                                      15~35 ° C

                    Humidity:                                         25~75 %

                    Atmospheric pressure:                             86~106 kPa

     4.4 Definitions of symbols used in this test report
      ■ - The black square indicates that the listed condition, standard or equipment is applicable for this report.
      □ - The empty square indicates that the listed condition, standard or equipment is not applicable for this report.

     4.5 Statement of the measurement uncertainty
     The data and results referenced in this document are true and accurate. The reader is cautioned that there may
     be errors within the calibration limits of the equipment and facilities. The measurement uncertainty was
     calculated for all measurements listed in this test report acc. to CISPR 16 - 4 “Specification for radio
     disturbance and immunity measuring apparatus and methods – Part 4: Uncertainty in EMC Measurements” and
     is documented in the CTS quality system acc. to DIN EN ISO/IEC 17025. Furthermore, component and process
     variability of devices similar to that tested may result in additional deviation. The manufacturer has the sole
     responsibility of continued compliance of the device.



Copyright of this report is owned by Centre of Testing Service and may not be reproduced other than in full except with the written approval of the issuing Company.


CENTRE OF TESTING SERVICE CO., LTD.
A101,No.65,Zhuji Highway,Tianhe District,Guangzhou, China
Tel:+86-20-85543113 (32 lines)                 Fax:+86-20-38780406
Complaint line:+86-20-85533471                 E-mail:cts@cts-lab.com.cn                         See Reverse For Terms And Conditions of Service


Report No.: CGZ3160104-00004-EFI                                                                                                                                       Page 7 of 32


       FCC ID:BRWBLH9012
       IC:6157A-BLH9012




     4.6 Measurement Uncertainty

                              Test Item                                       Frequency Range                                           Uncertainty                          Note
                  Conduction disturbance                                        150kHz~30MHz                                              1.22dB                            (1)
                     Power disturbance                                         30MHz~300MHz                                               1.38dB                            (1)
                                                                               30MHz~300MHz                                               3.14dB                            (1)
                     Radiation emission (3m)                                 300MHz~1000MHz                                               3.18dB                            (1)
                                                     1GHz~26.5GHz                     3.54dB             (1)
          (1) .This uncertainty represents an expanded uncertainty expressed at approximately the 95% confidence
               level using a coverage factor of k=2.


5.Summary of standards and results
     5.1.Description of Standards and Results
               The EUT have been tested according to the applicable standards as referenced below.
                                                                                           EMISSION

                              Description of Test Item                                                        Standard                                          Results
                                                                                                   FCC Part 15 § 15.207
                Conducted Emission Test                                                           RSS-Gen Issue 4§ 7.2.4                                               N/A
                                                                                                    ANSI C63.10:2013
                                                                                                   RSS-Gen Issue 4§ 7.2
                                                                                                  RSS-210 Issue 8 § A2.9
                Radiated Emission Test                                                            FCC Part 15 C § 15.249                                       PASSED
                                                                                                    FCC Part 15 § 209
                                                                                                    ANSI C63.10:2013
                                                                                                  RSS-Gen Issue 4§ 4.10
                Receiver Spurious Emissions                                                                                                                    PASSED
                                                                                                    ANSI C63.10:2013
                                                                                                  RSS-210 Issue 8 § 1.1
                                                                                                 RSS-Gen Issue 4 § 8.10
                Band Edge Compliance Test                                                                                                                      PASSED
                                                                                                 FCC Part 15 C § 15.249
                                                                                                   ANSI C63.10:2013
                                                                                                  RSS-Gen Issue 4 § 6.6
                99% Bandwidth                                                                                                                                  PASSED
                                                                                                   ANSI C63.10:2013
                N/A is an abbreviation for Not Applicable.




Copyright of this report is owned by Centre of Testing Service and may not be reproduced other than in full except with the written approval of the issuing Company.


CENTRE OF TESTING SERVICE CO., LTD.
A101,No.65,Zhuji Highway,Tianhe District,Guangzhou, China
Tel:+86-20-85543113 (32 lines)                 Fax:+86-20-38780406
Complaint line:+86-20-85533471                 E-mail:cts@cts-lab.com.cn                         See Reverse For Terms And Conditions of Service


Report No.: CGZ3160104-00004-EFI                                                                                                                                        Page 8 of 32


       FCC ID:BRWBLH9012
       IC:6157A-BLH9012




6.Power Line Conducted Emission Test
          6.1.Test Equipment
                    Conducted Disturbance
                     Item     Test Equipment                                    Manufacturer                               Model No.                 Serial No.            Last Cal.
                       1    EMI Test Receiver                                ROHDE & SCHWARZ                               ESHS10                   842884/012             2015/10
                       2      Artificial Mains                               ROHDE & SCHWARZ                               ESH3-Z5                  832479/025             2015/10
                       3      Artificial Mains                               ROHDE & SCHWARZ                               ESH3-Z5                  832479/026             2015/10
                       4       Pulse Limiter                                 ROHDE & SCHWARZ                               ESHSZ2                     100301               2015/10
                       5    EMI Test Software                                ROHDE & SCHWARZ                                ESK1                       N/A                 2015/10

         6.2. Block Diagram of Test Setup



                                                                                         EUT


                                                                               (EUT: Blade Inductrix 200 Quadcopter)



          6.3. Power Line Conducted Emission Test Limits
                  Standard:RSS-Gen:7.2.4,FCC Part 15 : 15.207,ANSI C63.10:2013

                                                                         Maximum RF Line Voltage
                             Frequency                      Quasi-Peak    Level            Average Level
                                                                  dB(V)                        dB(V)
                        150kHz        ~ 500kHz                   66 ~ 56*                      56 ~ 46*
                        500kHz        ~ 5MHz                         56                           46
                         5MHz         ~ 30MHz                        60                           50
                      Notes: 1. * Decreasing linearly with logarithm of frequency.
                             2. The lower limit shall apply at the transition frequencies.
         6.4.Test Procedure
               The Notebook Power connected to the power mains through a line impedance stabilization network
               (L.I.S.N.#2). This provides a 50 ohm coupling impedance for the EUT. Please refer the block diagram of
               the test setup and photographs. The other peripheral devices power cord connected to the power mains
               through a line impedance stabilization network (L.I.S.N.#1). Power on the PC and let it work normally, we
               use a keyboard test soft ware, let EUT working in test mode, then test it. Both sides of AC line are checked
               to find out the maximum conducted emission. In order to find the maximum emission levels, the relative
               positions of equipment and all of the interface cables shall be changed according to FCC Part 15C on
               Conducted Emission Test.


         6.5. Power Line Conducted Emission Test Results
                N/A
Copyright of this report is owned by Centre of Testing Service and may not be reproduced other than in full except with the written approval of the issuing Company.


CENTRE OF TESTING SERVICE CO., LTD.
A101,No.65,Zhuji Highway,Tianhe District,Guangzhou, China
Tel:+86-20-85543113 (32 lines)                 Fax:+86-20-38780406
Complaint line:+86-20-85533471                 E-mail:cts@cts-lab.com.cn                         See Reverse For Terms And Conditions of Service


Report No.: CGZ3160104-00004-EFI                                                                                                                                       Page 9 of 32


       FCC ID:BRWBLH9012
       IC:6157A-BLH9012




7.Radiated disturbance (electric field)
     7.1.Test Equipment
                   Radiated disturbance (electric field)
                   Item           Test Equipment                              Manufacturer                        Model No.                      Serial No.            Last Cal.
                      1        EMI Test Receiver                   ROHDE & SCHWARZ                                ESCI                             100868              2015/10
                      2        Biconical Antenna                   ROHDE & SCHWARZ                                HK116                            100221              2015/03
                      3        Log per Antenna                     ROHDE & SCHWARZ                                HL223                            100226              2015/03
                      4        Log per Antenna                     ROHDE & SCHWARZ                                HL050                            100186              2015/03
                      5        Signal analyzer                     ROHDE & SCHWARZ                                FSIQ26                           100311              2015/03
                      6        Loop Antenna                        A.R.A                                          PLA-1030/B                         1030              2015/10


     7.2.Block Diagram of Test Setup
                          7.2.1 Block Diagram of connection between EUT and simulators


                                                                                        TX

                                                                                        EUT




                                                                                                                                                                FRP Table




                                                                                  (EUT: Blade Inductrix 200 Quadcopter)




Copyright of this report is owned by Centre of Testing Service and may not be reproduced other than in full except with the written approval of the issuing Company.


CENTRE OF TESTING SERVICE CO., LTD.
A101,No.65,Zhuji Highway,Tianhe District,Guangzhou, China
Tel:+86-20-85543113 (32 lines)                 Fax:+86-20-38780406
Complaint line:+86-20-85533471                 E-mail:cts@cts-lab.com.cn                         See Reverse For Terms And Conditions of Service


Report No.: CGZ3160104-00004-EFI                                                                                                                                       Page 10 of 32


       FCC ID:BRWBLH9012
       IC:6157A-BLH9012




                          7.2.2 Anechoic Chamber Setup Diagram




       7.3.Radiated Emission Limit :
             Standard: FCC 15.249 , FCC 15.209; RSS-Gen:7.2; RSS-210 A2.9.
         Except as provided in paragraph (a) of this section, the field strength of emissions from intentional
         radiators operated within these frequency bands shall comply with the following:
                      Fundamental Frequency                                    Field Strength of                                   Field Strength of Harmonics
                             (MHz)                                           Fundamental (mV/m)                                               (µV/m)
                            902-928                                                   50                                                       500
                                2400-2483.5                                                  50                                                          500
                                  5725-5875                                                  50                                                          500
                                24000-24250                                                 250                                                        2500

                              FREQUENCY                                             DISTANCE
                                                                                         FIELD STRENGTHS LIMIT
                                 MHz                                                      V/m
                                                                                      Meters                dB(V)/m
                         0.009     ~   0.490                                           300
                                                                                      2400/F(kHz)               ---
                         0.490     ~   1.705                                            30
                                                                                     24000/F(kHz)               ---
                         1.705     ~     30                                             30  30                  ---
                           30      ~     88                                             3  100                 40.0
                           88      ~    216                                             3  150                 43.5
                          216      ~    960                                             3  200                 46.0
                          960      ~   1000                                             3  500                 54.0
                                                                                         Other:74.0 dB(V)/m (Peak)
                               Above 1000                        3
                                                                                          54.0 dB(V)/m (Average)
                            Remark: (1) Emission level dBV = 20 log Emission level V/m
                                    (2) The smaller limit shall apply at the cross point between two frequency bands.
                                    (3) Distance is the distance in meters between the measuring instrument, antenna and
                                     the closest point of any part of the device or system.

Copyright of this report is owned by Centre of Testing Service and may not be reproduced other than in full except with the written approval of the issuing Company.


CENTRE OF TESTING SERVICE CO., LTD.
A101,No.65,Zhuji Highway,Tianhe District,Guangzhou, China
Tel:+86-20-85543113 (32 lines)                 Fax:+86-20-38780406
Complaint line:+86-20-85533471                 E-mail:cts@cts-lab.com.cn                         See Reverse For Terms And Conditions of Service


Report No.: CGZ3160104-00004-EFI                                                                                                                                       Page 11 of 32


       FCC ID:BRWBLH9012
       IC:6157A-BLH9012




      7.4.Test Procedure
             The EUT and its simulators are placed on a turn table, which is 0.8 meter high above ground. The turn table
             can rotate 360 degrees to determine the position of the maximum emission level. The EUT is set 3 meters
             away from the receiving antenna, which is mounted on a antenna tower. The antenna can be moved up and
             down between 1 meter and 4 meters to find out the maximum emission level. Broadband antenna
             (calibrated bilog antenna) is used as receiving antenna. Both horizontal and vertical polarization of the
             antenna is set on Test. In order to find the maximum emission levels, all of the interface cables must be
             manipulated according to ANSI C63.10:2013 on radiated emission Test.
             The frequency range from 30MHz to 1000MHz and above 1GHz. is investigated. Please see the following
             pages.
             All measurements for radiated emissions within the restricted bands were performed using a Quasi-Peak
             detector with 120kHz RBW below 1GHz and a Peak and Average detector with 2MHz RBW above 1GHz,
             All measurements for radiated emissions within the restricted bands were performed using a Quasi-Peak
             detector with 300kHz VBW below 1GHz and a Peak detector with1MHz VBW above 1GHz, A average
             detector with 10Hz VBW above 1GHz
             Pretest x, y, z position of EUT, final, select the worst case x position test and record the test results in the
             report.

             The test modes (TX Mode) is tested in Anechoic Chamber and all the scanning waveforms are reported on
             section 7.5
     7.5.Radiated Emission Test Results
             PASSED.

             The frequency range from 9KHz~30MHz,30MHz to 230MHz, 230MHz to 1000MHz and above 1GHz. is
             investigated. Please see the following pages.




Copyright of this report is owned by Centre of Testing Service and may not be reproduced other than in full except with the written approval of the issuing Company.


CENTRE OF TESTING SERVICE CO., LTD.
A101,No.65,Zhuji Highway,Tianhe District,Guangzhou, China
Tel:+86-20-85543113 (32 lines)                 Fax:+86-20-38780406
Complaint line:+86-20-85533471                 E-mail:cts@cts-lab.com.cn                         See Reverse For Terms And Conditions of Service


Report No.: CGZ3160104-00004-EFI                                                                                                                                       Page 12 of 32


       FCC ID:BRWBLH9012
       IC:6157A-BLH9012




                      Test Mode:                                TX –X Position Mode                                     Result:            ■ - passed
                      Frequency range:                          9KHz~30MHz                                                                 □ - not passed


                       No.  Frequency Factor           Reading         Level         Limit      Margin                                                          Det.
                               (MHz)        (dB)       (dBuV)        (dBuV/m) (dBuV/m)            (dB)
                       Remark: The test result reading value is to low, margin all > 10dB of the limit.




Copyright of this report is owned by Centre of Testing Service and may not be reproduced other than in full except with the written approval of the issuing Company.


CENTRE OF TESTING SERVICE CO., LTD.
A101,No.65,Zhuji Highway,Tianhe District,Guangzhou, China
Tel:+86-20-85543113 (32 lines)                 Fax:+86-20-38780406
Complaint line:+86-20-85533471                 E-mail:cts@cts-lab.com.cn                         See Reverse For Terms And Conditions of Service


Report No.: CGZ3160104-00004-EFI                                                                                                                                       Page 13 of 32


       FCC ID:BRWBLH9012
       IC:6157A-BLH9012




              Channel:                                TX –X Position                                                      Result: ■ - passed
              Test point:                             Horizontal                                                                  □ - not passed
              Frequency range:                        30MHz-1GHz

               EUT                                                Blade Inductrix 200 Quadcopter
               Test Condition                                     Ambient Temperature: 25°C Humidity: 56%
               Test distance                                      3 Meter
               Test Date:                                         04~11 January 2016
               Operator                                           Duke
               MODEL NO                                           BLH9080




                  No.  Frequency     Factor      Reading          Level                                                     Limit               Margin                 Det.
                          (MHz)        (dB)       (dBuV)        (dBuV/m)                                                  (dBuV/m)               (dB)
                 1       30.5411      -16.11       36.79          20.68                                                     40.00               -19.32                 QP
                 2       99.7996      -18.24       37.41          19.17                                                     43.50               -24.33                 QP
                 3      134.4289      -16.10       38.46          22.36                                                     43.50               -21.14                 QP
                 4      181.5030      -15.06       44.13          29.07                                                     43.50               -14.43                 QP
                 5      192.8657      -13.78       46.00          32.22                                                     43.50               -11.28                 QP
                 6      297.8357       -1.99       34.42          32.43                                                     46.00               -13.57                 QP
               Remark: Other frequency mini margin all >6 dB of Limit




Copyright of this report is owned by Centre of Testing Service and may not be reproduced other than in full except with the written approval of the issuing Company.


CENTRE OF TESTING SERVICE CO., LTD.
A101,No.65,Zhuji Highway,Tianhe District,Guangzhou, China
Tel:+86-20-85543113 (32 lines)                 Fax:+86-20-38780406
Complaint line:+86-20-85533471                 E-mail:cts@cts-lab.com.cn                         See Reverse For Terms And Conditions of Service


Report No.: CGZ3160104-00004-EFI                                                                                                                                        Page 14 of 32


       FCC ID:BRWBLH9012
       IC:6157A-BLH9012




                  No.  Frequency     Factor      Reading          Level                                                     Limit               Margin                 Det.
                          (MHz)        (dB)       (dBuV)        (dBuV/m)                                                  (dBuV/m)               (dB)
                 1      328.0561      -12.35       37.90          25.55                                                     46.00               -20.45                 QP
                 2      586.1723       -5.59       40.36          34.77                                                     46.00               -11.23                 QP
                 3      675.9519       -3.48       36.24          32.76                                                     46.00               -13.24                 QP
                 4      800.8016       -3.22       37.38          34.16                                                     46.00               -11.84                 QP
                 5      821.8437       -1.97       40.90          38.93                                                     46.00                -7.07                 QP
                 6      863.9279       -0.71       33.50          32.79                                                     46.00               -13.21                 QP
               Remark: Other frequency mini margin all >6 dB of Limit




Copyright of this report is owned by Centre of Testing Service and may not be reproduced other than in full except with the written approval of the issuing Company.


CENTRE OF TESTING SERVICE CO., LTD.
A101,No.65,Zhuji Highway,Tianhe District,Guangzhou, China
Tel:+86-20-85543113 (32 lines)                 Fax:+86-20-38780406
Complaint line:+86-20-85533471                 E-mail:cts@cts-lab.com.cn                         See Reverse For Terms And Conditions of Service


Report No.: CGZ3160104-00004-EFI                                                                                                                                        Page 15 of 32


       FCC ID:BRWBLH9012
       IC:6157A-BLH9012




              Channel:                                TX –X Position Low CH                                               Result: ■ - passed
              Test point:                             Horizontal                                                                  □ - not passed
              Frequency range:                        1GHz-26.5GHz

                  No.          Frequency                Factor              Reading                  Level                   Limit              Margin                 Det.
                                 (MHz)                   (dB)               (dBuV)                 (dBuV/m)               (dBuV/m)               (dB)
                    1           2404.00                  -6.83               94.28                   87.45                  114.00              -26.55                 Peak
                    2           2404.00                  -6.83               91.10                   84.27                  94.00                -9.73                 AVG

                  No.  Frequency     Factor      Reading          Level                                                     Limit               Margin                 Det.
                          (MHz)        (dB)       (dBuV)        (dBuV/m)                                                  (dBuV/m)               (dB)
                 1      1749.499      -10.88       44.76          33.88                                                     74.00               -40.12                 peak
                 2      1749.499      -10.88       31.03          20.15                                                     54.00               -33.85                 AVG
                 3      5452.906       4.60        39.02          43.62                                                     74.00               -30.38                 peak
                 4      5452.906       4.60        24.04          28.64                                                     54.00               -25.36                 AVG
               Remark: Other frequency mini margin all >6 dB of Limit

              Channel:                                TX –X Position Middle CH                                            Result: ■ - passed
              Test point:                             Horizontal                                                                  □ - not passed
              Frequency range:                        1GHz-26.5GHz

                  No.          Frequency                Factor              Reading                  Level                   Limit              Margin                 Det.
                                 (MHz)                   (dB)               (dBuV)                 (dBuV/m)               (dBuV/m)               (dB)
                    1           2440.00                  -6.62               93.86                   87.24                  114.00              -26.76                 Peak
                    2           2440.00                  -6.62               90.31                   83.69                  94.00               -10.31                 AVG

                  No.  Frequency     Factor      Reading          Level                                                     Limit               Margin                 Det.
                          (MHz)        (dB)       (dBuV)        (dBuV/m)                                                  (dBuV/m)               (dB)
                 1      1925.852       -9.72       39.72          30.00                                                     74.00               -44.00                 peak
                 2      1925.852      -9.72        26.07          16.35                                                     54.00               -37.65                 AVG
                 3      5034.068        3.39       37.63          41.02                                                     74.00               -32.98                 peak
                 4      5034.068       3.39        23.09          26.48                                                     54.00               -27.52                 AVG
               Remark: Other frequency mini margin all >6 dB of Limit

              Channel:                                TX –X Position High CH                                              Result: ■ - passed
              Test point:                             Horizontal                                                                  □ - not passed
              Frequency range:                        1GHz-26.5GHz

                  No.          Frequency                Factor              Reading                  Level                   Limit              Margin                 Det.
                                 (MHz)                   (dB)               (dBuV)                 (dBuV/m)               (dBuV/m)               (dB)
                    1           2476.00                  -6.40               93.75                   87.35                  114.00              -26.65                 Peak
                    2           2476.00                  -6.40               89.84                   83.44                  94.00               -10.56                 AVG

                  No.  Frequency     Factor      Reading          Level                                                     Limit               Margin                 Det.
                          (MHz)        (dB)       (dBuV)        (dBuV/m)                                                  (dBuV/m)               (dB)
                 1      1705.411      -11.17       38.32          27.15                                                     74.00               -46.85                 peak
                 2      1705.411      -11.17       24.79          13.62                                                     54.00               -40.38                 AVG
                 3      5276.553       4.09        36.54          40.63                                                     74.00               -33.37                 peak
                 4      5276.553       4.09        22.48          26.57                                                     54.00               -27.43                 AVG
               Remark: Other frequency mini margin all >6 dB of Limit

Copyright of this report is owned by Centre of Testing Service and may not be reproduced other than in full except with the written approval of the issuing Company.


CENTRE OF TESTING SERVICE CO., LTD.
A101,No.65,Zhuji Highway,Tianhe District,Guangzhou, China
Tel:+86-20-85543113 (32 lines)                 Fax:+86-20-38780406
Complaint line:+86-20-85533471                 E-mail:cts@cts-lab.com.cn                         See Reverse For Terms And Conditions of Service


Report No.: CGZ3160104-00004-EFI                                                                                                                                        Page 16 of 32


       FCC ID:BRWBLH9012
       IC:6157A-BLH9012




              Channel:                                TX –X Position                                                      Result: ■ - passed
              Test point:                             Vertical                                                                    □ - not passed
              Frequency range:                        30MHz-1GHz




                  No.  Frequency     Factor      Reading          Level                                                     Limit               Margin                 Det.
                          (MHz)        (dB)       (dBuV)        (dBuV/m)                                                  (dBuV/m)               (dB)
                 1       38.1162      -17.09       34.57          17.48                                                     40.00               -22.52                 QP
                 2       93.8477      -18.79       32.57          13.78                                                     43.50               -29.72                 QP
                 3      121.4429      -16.64       33.63          16.99                                                     43.50               -26.51                 QP
                 4      151.2024      -15.96       32.49          16.53                                                     43.50               -26.97                 QP
                 5      202.0641      -11.85       32.92          21.07                                                     43.50               -22.43                 QP
                 6      277.2745       -7.93       33.35          25.42                                                     46.00               -20.58                 QP
               Remark: Other frequency mini margin all >6 dB of Limit




Copyright of this report is owned by Centre of Testing Service and may not be reproduced other than in full except with the written approval of the issuing Company.


CENTRE OF TESTING SERVICE CO., LTD.
A101,No.65,Zhuji Highway,Tianhe District,Guangzhou, China
Tel:+86-20-85543113 (32 lines)                 Fax:+86-20-38780406
Complaint line:+86-20-85533471                 E-mail:cts@cts-lab.com.cn                         See Reverse For Terms And Conditions of Service


Report No.: CGZ3160104-00004-EFI                                                                                                                                        Page 17 of 32


       FCC ID:BRWBLH9012
       IC:6157A-BLH9012




                  No.  Frequency     Factor      Reading          Level                                                     Limit               Margin                 Det.
                          (MHz)        (dB)       (dBuV)        (dBuV/m)                                                  (dBuV/m)               (dB)
                 1      365.9319      -11.08       44.74          33.66                                                     46.00               -12.34                 QP
                 2      580.5611       -5.60       38.18          32.58                                                     46.00               -13.42                 QP
                 3      746.0922       -1.76       31.06          29.30                                                     46.00               -16.70                 QP
                 4      821.8437       -1.97       35.24          33.27                                                     46.00               -12.73                 QP
                 5      855.5110       -0.46       33.04          32.58                                                     46.00               -13.42                 QP
                 6      948.0962        0.34       31.33          31.67                                                     46.00               -14.33                 QP
               Remark: Other frequency mini margin all >6 dB of Limit




Copyright of this report is owned by Centre of Testing Service and may not be reproduced other than in full except with the written approval of the issuing Company.


CENTRE OF TESTING SERVICE CO., LTD.
A101,No.65,Zhuji Highway,Tianhe District,Guangzhou, China
Tel:+86-20-85543113 (32 lines)                 Fax:+86-20-38780406
Complaint line:+86-20-85533471                 E-mail:cts@cts-lab.com.cn                         See Reverse For Terms And Conditions of Service


Report No.: CGZ3160104-00004-EFI                                                                                                                                        Page 18 of 32


       FCC ID:BRWBLH9012
       IC:6157A-BLH9012




              Channel:                                TX –X Position Low CH                                               Result: ■ - passed
              Test point:                             Vertical                                                                    □ - not passed
              Frequency range:                        1GHz-26.5GHz

                  No.          Frequency                Factor              Reading                  Level                   Limit              Margin                 Det.
                                 (MHz)                   (dB)               (dBuV)                 (dBuV/m)               (dBuV/m)               (dB)
                    1           2404.00                  -6.83               90.42                   83.59                  114.00              -30.41                 Peak
                    2           2404.00                  -6.83               88.45                   81.62                  94.00               -12.38                 AVG

                  No.  Frequency     Factor      Reading          Level                                                     Limit               Margin                 Det.
                          (MHz)        (dB)       (dBuV)        (dBuV/m)                                                  (dBuV/m)               (dB)
                 1      1903.808       -9.86       47.27          37.41                                                     74.00               -36.59                 peak
                 2      1903.808      -9.86        32.22          22.36                                                     54.00               -31.64                 AVG
                 3      4989.980        3.26       38.15          41.41                                                     74.00               -32.59                 peak
                 4      4989.980       3.26        23.32          26.58                                                     54.00               -27.42                 AVG
               Remark: Other frequency mini margin all >6 dB of Limit

              Channel:                                TX –X Position Middle CH                                            Result: ■ - passed
              Test point:                             Vertical                                                                    □ - not passed
              Frequency range:                        1GHz-26.5GHz

                  No.          Frequency                Factor              Reading                  Level                   Limit              Margin                 Det.
                                 (MHz)                   (dB)               (dBuV)                 (dBuV/m)               (dBuV/m)               (dB)
                    1           2440.00                  -6.62               90.79                   84.17                  114.00              -29.83                 Peak
                    2           2440.00                  -6.62               87.84                   81.22                  94.00               -12.78                 AVG

                  No.  Frequency     Factor      Reading          Level                                                     Limit               Margin                 Det.
                          (MHz)        (dB)       (dBuV)        (dBuV/m)                                                  (dBuV/m)               (dB)
                 1      1903.808       -9.86       37.89          28.03                                                     74.00               -45.97                 peak
                 2      1903.808      -9.86        24.45          14.59                                                     54.00               -39.41                 AVG
                 3      5188.377        3.84       36.47          40.31                                                     74.00               -33.69                 peak
                 4      5188.377       3.84        22.53          26.37                                                     54.00               -27.63                 AVG
               Remark: Other frequency mini margin all >6 dB of Limit

              Channel:                                TX –X Position High CH                                              Result: ■ - passed
              Test point:                             Vertical                                                                    □ - not passed
              Frequency range:                        1GHz-26.5GHz

                  No.          Frequency                Factor              Reading                  Level                   Limit              Margin                 Det.
                                 (MHz)                   (dB)               (dBuV)                 (dBuV/m)               (dBuV/m)               (dB)
                    1           2476.00                  -6.40               90.69                   84.29                  114.00              -29.71                 Peak
                    2           2476.00                  -6.40               86.99                   80.59                  94.00               -13.41                 AVG

                  No.  Frequency     Factor      Reading          Level                                                     Limit               Margin                 Det.
                          (MHz)        (dB)       (dBuV)        (dBuV/m)                                                  (dBuV/m)               (dB)
                 1      1837.675      -10.30       39.04          28.74                                                     74.00               -45.26                 peak
                 2      1837.675      -10.30       24.66          14.36                                                     54.00               -39.64                 AVG
                 3      5563.126       4.98        36.20          41.18                                                     74.00               -32.82                 peak
                 4      5563.126       4.98        21.89          26.87                                                     54.00               -27.13                 AVG
               Remark: Other frequency mini margin all >6 dB of Limit

Copyright of this report is owned by Centre of Testing Service and may not be reproduced other than in full except with the written approval of the issuing Company.


CENTRE OF TESTING SERVICE CO., LTD.
A101,No.65,Zhuji Highway,Tianhe District,Guangzhou, China
Tel:+86-20-85543113 (32 lines)                 Fax:+86-20-38780406
Complaint line:+86-20-85533471                 E-mail:cts@cts-lab.com.cn                         See Reverse For Terms And Conditions of Service


Report No.: CGZ3160104-00004-EFI                                                                                                                                        Page 19 of 32


       FCC ID:BRWBLH9012
       IC:6157A-BLH9012




              Channel:                                RX                                                                  Result: ■ - passed
              Test point:                             Horizontal                                                                  □ - not passed
              Frequency range:                        30MHz-1GHz

               EUT                                                Blade Inductrix 200 Quadcopter
               Test Condition                                     Ambient Temperature: 25°C Humidity: 56%
               Test distance                                      3 Meter
               Test Date:                                         04~11 January 2016
               Operator                                           Duke
               MODEL NO                                           BLH9080




                  No.  Frequency     Factor      Reading          Level                                                     Limit               Margin                 Det.
                          (MHz)        (dB)       (dBuV)        (dBuV/m)                                                  (dBuV/m)               (dB)
                 1      104.6693      -17.79       36.50          18.71                                                     43.50               -24.79                 QP
                 2      139.2986      -16.06       39.22          23.16                                                     43.50               -20.34                 QP
                 3      159.8597      -15.97       43.65          27.68                                                     43.50               -15.82                 QP
                 4      185.8317      -14.71       46.21          31.50                                                     43.50               -12.00                 QP
                 5      195.5711      -13.21       45.62          32.41                                                     43.50               -11.09                 QP
                 6      295.1303       -2.71       35.28          32.57                                                     46.00               -13.43                 QP
               Remark: Other frequency mini margin all >6 dB of Limit




Copyright of this report is owned by Centre of Testing Service and may not be reproduced other than in full except with the written approval of the issuing Company.


CENTRE OF TESTING SERVICE CO., LTD.
A101,No.65,Zhuji Highway,Tianhe District,Guangzhou, China
Tel:+86-20-85543113 (32 lines)                 Fax:+86-20-38780406
Complaint line:+86-20-85533471                 E-mail:cts@cts-lab.com.cn                         See Reverse For Terms And Conditions of Service


Report No.: CGZ3160104-00004-EFI                                                                                                                                        Page 20 of 32


       FCC ID:BRWBLH9012
       IC:6157A-BLH9012




                  No.  Frequency     Factor      Reading          Level                                                     Limit               Margin                 Det.
                          (MHz)        (dB)       (dBuV)        (dBuV/m)                                                  (dBuV/m)               (dB)
                 1      311.2224      -13.11       38.97          25.86                                                     46.00               -20.14                 QP
                 2      496.3928       -8.14       32.75          24.61                                                     46.00               -21.39                 QP
                 3      579.1583       -5.60       42.80          37.20                                                     46.00                -8.80                 QP
                 4      622.6453       -4.50       38.12          33.62                                                     46.00               -12.38                 QP
                 5      814.8297       -2.39       41.61          39.22                                                     46.00                -6.78                 QP
                 6      845.6914       -0.55       34.04          33.49                                                     46.00               -12.51                 QP
               Remark: Other frequency mini margin all >6 dB of Limit

              Channel:                                RX                                                                  Result: ■ - passed
              Test point:                             Horizontal                                                                  □ - not passed
              Frequency range:                        1GHz-26.5GHz

                  No.  Frequency     Factor      Reading          Level                                                     Limit               Margin                 Det.
                          (MHz)        (dB)       (dBuV)        (dBuV/m)                                                  (dBuV/m)               (dB)
                 1      1484.970      -12.67       37.44          24.77                                                     74.00               -49.23                 peak
                 2      1484.970      -12.67       24.02          11.35                                                     54.00               -42.65                 AVG
                 3      5122.244       3.64        35.52          39.16                                                     74.00               -34.84                 peak
                 4      5122.244       3.64        20.95          24.59                                                     54.00               -29.41                 AVG
               Remark: Other frequency mini margin all >6 dB of Limit




Copyright of this report is owned by Centre of Testing Service and may not be reproduced other than in full except with the written approval of the issuing Company.


CENTRE OF TESTING SERVICE CO., LTD.
A101,No.65,Zhuji Highway,Tianhe District,Guangzhou, China
Tel:+86-20-85543113 (32 lines)                 Fax:+86-20-38780406
Complaint line:+86-20-85533471                 E-mail:cts@cts-lab.com.cn                         See Reverse For Terms And Conditions of Service


Report No.: CGZ3160104-00004-EFI                                                                                                                                        Page 21 of 32


       FCC ID:BRWBLH9012
       IC:6157A-BLH9012




              Channel:                                RX                                                                  Result: ■ - passed
              Test point:                             Vertical                                                                    □ - not passed
              Frequency range:                        30MHz-1GHz




                  No.  Frequency     Factor      Reading          Level                                                     Limit               Margin                 Det.
                          (MHz)        (dB)       (dBuV)        (dBuV/m)                                                  (dBuV/m)               (dB)
                 1       37.0341      -16.95       34.38          17.43                                                     40.00               -22.57                 QP
                 2      110.6212      -17.26       33.89          16.63                                                     43.50               -26.87                 QP
                 3      150.1202      -15.96       33.07          17.11                                                     43.50               -26.39                 QP
                 4      177.7154      -15.36       35.86          20.50                                                     43.50               -23.00                 QP
                 5      210.7214      -10.24       33.54          23.30                                                     43.50               -20.20                 QP
                 6      292.4248       -3.43       31.09          27.66                                                     46.00               -18.34                 QP
               Remark: Other frequency mini margin all >6 dB of Limit




Copyright of this report is owned by Centre of Testing Service and may not be reproduced other than in full except with the written approval of the issuing Company.


CENTRE OF TESTING SERVICE CO., LTD.
A101,No.65,Zhuji Highway,Tianhe District,Guangzhou, China
Tel:+86-20-85543113 (32 lines)                 Fax:+86-20-38780406
Complaint line:+86-20-85533471                 E-mail:cts@cts-lab.com.cn                         See Reverse For Terms And Conditions of Service


Report No.: CGZ3160104-00004-EFI                                                                                                                                        Page 22 of 32


       FCC ID:BRWBLH9012
       IC:6157A-BLH9012




                  No.  Frequency     Factor      Reading          Level                                                     Limit               Margin                 Det.
                          (MHz)        (dB)       (dBuV)        (dBuV/m)                                                  (dBuV/m)               (dB)
                 1      364.5291      -11.11       46.09          34.98                                                     46.00               -11.02                 QP
                 2      559.5190       -5.66       34.27          28.61                                                     46.00               -17.39                 QP
                 3      579.1583       -5.60       37.90          32.30                                                     46.00               -13.70                 QP
                 4      612.8257       -4.95       33.95          29.00                                                     46.00               -17.00                 QP
                 5      819.0381       -2.14       35.45          33.31                                                     46.00               -12.69                 QP
                 6      934.0681       -0.28       31.30          31.02                                                     46.00               -14.98                 QP
               Remark: Other frequency mini margin all >6 dB of Limit

              Channel:                                RX                                                                  Result: ■ - passed
              Test point:                             Vertical                                                                    □ - not passed
              Frequency range:                        1GHz-26.5GHz



                  No.  Frequency     Factor      Reading          Level                                                     Limit               Margin                 Det.
                          (MHz)        (dB)       (dBuV)        (dBuV/m)                                                  (dBuV/m)               (dB)
                 1      1573.146      -12.05       38.73          26.68                                                     74.00               -47.32                 peak
                 2      1573.146      -12.05       24.40          12.35                                                     54.00               -41.65                 AVG
                 3      6114.229       6.83        38.76          45.59                                                     74.00               -28.41                 peak
                 4      6114.229       6.83        23.35          30.18                                                     54.00               -23.82                 AVG
               Remark: Other frequency mini margin all >6 dB of Limit




Copyright of this report is owned by Centre of Testing Service and may not be reproduced other than in full except with the written approval of the issuing Company.


CENTRE OF TESTING SERVICE CO., LTD.
A101,No.65,Zhuji Highway,Tianhe District,Guangzhou, China
Tel:+86-20-85543113 (32 lines)                 Fax:+86-20-38780406
Complaint line:+86-20-85533471                 E-mail:cts@cts-lab.com.cn                         See Reverse For Terms And Conditions of Service


Report No.: CGZ3160104-00004-EFI                                                                                                                                        Page 23 of 32


       FCC ID:BRWBLH9012
       IC:6157A-BLH9012




8.Band Edge Compliance test
     8.1. Test Equipment
       Band Edge Compliance test
              Item                   Test Equipment                                Manufacturer                        Model No.                  Serial No.              Last Cal.
                 1               EMI Test Receiver                        ROHDE & SCHWARZ                                  ESCI                      10868                2015/10
                 2               Log per Antenna                          ROHDE & SCHWARZ                                 HL050                     100186                2015/03
                 3               Signal analyzer                          ROHDE & SCHWARZ                                FSIQ26                     100311                2015/03

     8.2. Test Information
       EUT                                                        Blade Inductrix 200 Quadcopter
       Test Condition                                             Ambient Temperature: 25°C Humidity: 56%
       Test distance                                              3 Meter
       Test Date:                                                 04~11 January 2016
       Operator                                                   Duke
       MODEL NO                                                   BLH9080


     8.3. Test procedure
             1、 The EUT operates at hopping-off test mode. The lowest or highest channels are tested to verify the
                largest transmission and spurious emissions power at the continuous transmission mode.
             2、 Max hold the trace of the setp 1,and the EUT operates at hopping-on test mode to verify the largest
                spurious emissions power.
             3、 Set the spectrum analyzer in the following setting in order to capture the lower and
                upper band-edges of the emission:
                (a) PEAK: RBW=VBW=1MHz / Sweep=AUTO
                (b) AVERAGE: RBW=1MHz ; VBW=1KHz(1/on Time) / Sweep=AUTO
     8.4. Test Results
         PASSED.
          The EUT operates at hopping-off test mode. The lowest and highest channels are tested to verify the
          band edge emissions.
                                                                                                                                     Test Result
                                                                                                                                  Highest Emission
                                                            Channel                                                                   (dBuv/m)
               Test Mode
                                                        Marked Frequency                                              Horizontal                               Vertical
                                                                                                                 Peak              Average              Peak           Average
                                                                2390MHz                                         50.03                24.79             47.94            22.96
             Low Channel
                                                                2400MHz                                         60.18                39.22             57.44            36.24
                                                              2483.5MHz                                         55.03                26.23             51.82            23.73
             High Channel
                                                                2500MHz                                         45.46                22.96             42.24            20.71
Copyright of this report is owned by Centre of Testing Service and may not be reproduced other than in full except with the written approval of the issuing Company.


CENTRE OF TESTING SERVICE CO., LTD.
A101,No.65,Zhuji Highway,Tianhe District,Guangzhou, China
Tel:+86-20-85543113 (32 lines)                 Fax:+86-20-38780406
Complaint line:+86-20-85533471                 E-mail:cts@cts-lab.com.cn                         See Reverse For Terms And Conditions of Service


Report No.: CGZ3160104-00004-EFI                                                                                                                                       Page 24 of 32


       FCC ID:BRWBLH9012
       IC:6157A-BLH9012




                          Band Edges (Low)

                                                     Detector mode:Peak                                    Polarity:Horizontal




                                               Detector mode:Average                                              Polarity:Horizontal




Copyright of this report is owned by Centre of Testing Service and may not be reproduced other than in full except with the written approval of the issuing Company.


CENTRE OF TESTING SERVICE CO., LTD.
A101,No.65,Zhuji Highway,Tianhe District,Guangzhou, China
Tel:+86-20-85543113 (32 lines)                 Fax:+86-20-38780406
Complaint line:+86-20-85533471                 E-mail:cts@cts-lab.com.cn                         See Reverse For Terms And Conditions of Service


Report No.: CGZ3160104-00004-EFI                                                                                                                                       Page 25 of 32


       FCC ID:BRWBLH9012
       IC:6157A-BLH9012




                                                        Detector mode:Peak                                   Polarity:Vertical




                                                 Detector mode:Average                                              Polarity:Vertical




Copyright of this report is owned by Centre of Testing Service and may not be reproduced other than in full except with the written approval of the issuing Company.


CENTRE OF TESTING SERVICE CO., LTD.
A101,No.65,Zhuji Highway,Tianhe District,Guangzhou, China
Tel:+86-20-85543113 (32 lines)                 Fax:+86-20-38780406
Complaint line:+86-20-85533471                 E-mail:cts@cts-lab.com.cn                         See Reverse For Terms And Conditions of Service


Report No.: CGZ3160104-00004-EFI                                                                                                                                       Page 26 of 32


       FCC ID:BRWBLH9012
       IC:6157A-BLH9012




                          Band Edges (High)

                                                     Detector mode:Peak                                    Polarity:Horizontal




                                               Detector mode:Average                                              Polarity:Horizontal




Copyright of this report is owned by Centre of Testing Service and may not be reproduced other than in full except with the written approval of the issuing Company.


CENTRE OF TESTING SERVICE CO., LTD.
A101,No.65,Zhuji Highway,Tianhe District,Guangzhou, China
Tel:+86-20-85543113 (32 lines)                 Fax:+86-20-38780406
Complaint line:+86-20-85533471                 E-mail:cts@cts-lab.com.cn                         See Reverse For Terms And Conditions of Service


Report No.: CGZ3160104-00004-EFI                                                                                                                                       Page 27 of 32


       FCC ID:BRWBLH9012
       IC:6157A-BLH9012




                                                        Detector mode:Peak                                   Polarity:Vertical




                                                 Detector mode:Average                                              Polarity:Vertical




Copyright of this report is owned by Centre of Testing Service and may not be reproduced other than in full except with the written approval of the issuing Company.


CENTRE OF TESTING SERVICE CO., LTD.
A101,No.65,Zhuji Highway,Tianhe District,Guangzhou, China
Tel:+86-20-85543113 (32 lines)                 Fax:+86-20-38780406
Complaint line:+86-20-85533471                 E-mail:cts@cts-lab.com.cn                         See Reverse For Terms And Conditions of Service


Report No.: CGZ3160104-00004-EFI                                                                                                                                       Page 28 of 32


       FCC ID:BRWBLH9012
       IC:6157A-BLH9012




9. 99% bandwidth

         9.1 Test procedure
         According to RSS-210 A1.1.3 and RSS-Gen 4.6.1 The Receiver output is connected to the spectrum analyzer.
         The resolution bandwidth shall be set to as close to 1% of the selected span as is possible without being below
         1%. The video bandwidth shall be set to 3 times the resolution bandwidth. Video averaging is not permitted.
         Where practical, a sampling detector shall be used given that a peak or peak hold may produce a wider
         bandwidth than actual. The sweep time is coupled.


         9.2. Test Equipment
                    Band Edge Compliance test
                     Item        Test Equipment                             Manufacturer                              Model No.               Serial No.                Last Cal.
                        1        Log per Antenna                        ROHDE & SCHWARZ                                  HL050                  100186                 2015/03/30
                        2        Signal analyzer                        ROHDE & SCHWARZ                                 FSIQ26                  100311                 2015/03/25


         9.3. Test Results
             PASSED.

                                                                                        Frequency                                                   Bandwidth
                                   Channel
                                                                                          (MHz)                                                       (MHz)
                                       Low                                                 2404                                                       1.208
                                     Middle                                                  2440                                                        1.204
                                      High                                                   2476                                                        1.224




Copyright of this report is owned by Centre of Testing Service and may not be reproduced other than in full except with the written approval of the issuing Company.


CENTRE OF TESTING SERVICE CO., LTD.
A101,No.65,Zhuji Highway,Tianhe District,Guangzhou, China
Tel:+86-20-85543113 (32 lines)                 Fax:+86-20-38780406
Complaint line:+86-20-85533471                 E-mail:cts@cts-lab.com.cn                         See Reverse For Terms And Conditions of Service


Report No.: CGZ3160104-00004-EFI                                                                                                                                        Page 29 of 32


       FCC ID:BRWBLH9012
       IC:6157A-BLH9012




                                                           99% Bandwidth                              Low CH: 2404MHz




                                                         99% Bandwidth                              Middle CH: 2440MHz




Copyright of this report is owned by Centre of Testing Service and may not be reproduced other than in full except with the written approval of the issuing Company.


CENTRE OF TESTING SERVICE CO., LTD.
A101,No.65,Zhuji Highway,Tianhe District,Guangzhou, China
Tel:+86-20-85543113 (32 lines)                 Fax:+86-20-38780406
Complaint line:+86-20-85533471                 E-mail:cts@cts-lab.com.cn                         See Reverse For Terms And Conditions of Service


Report No.: CGZ3160104-00004-EFI                                                                                                                                       Page 30 of 32


       FCC ID:BRWBLH9012
       IC:6157A-BLH9012




                                                           99% Bandwidth                             High CH: 2476MHz




Copyright of this report is owned by Centre of Testing Service and may not be reproduced other than in full except with the written approval of the issuing Company.


CENTRE OF TESTING SERVICE CO., LTD.
A101,No.65,Zhuji Highway,Tianhe District,Guangzhou, China
Tel:+86-20-85543113 (32 lines)                 Fax:+86-20-38780406
Complaint line:+86-20-85533471                 E-mail:cts@cts-lab.com.cn                         See Reverse For Terms And Conditions of Service


Report No.: CGZ3160104-00004-EFI                                                                                                                                       Page 31 of 32


       FCC ID:BRWBLH9012
       IC:6157A-BLH9012




10.Deviation to test specifications
                          The following identical model(s):




                                                                                                           N/A


                          Belong to the tested device:


                                                                 Product description: Blade Inductrix 200 Quadcopter
                                                                                Model name: BLH9080




Copyright of this report is owned by Centre of Testing Service and may not be reproduced other than in full except with the written approval of the issuing Company.


CENTRE OF TESTING SERVICE CO., LTD.
A101,No.65,Zhuji Highway,Tianhe District,Guangzhou, China
Tel:+86-20-85543113 (32 lines)                 Fax:+86-20-38780406
Complaint line:+86-20-85533471                 E-mail:cts@cts-lab.com.cn                         See Reverse For Terms And Conditions of Service


Report No.: CGZ3160104-00004-EFI                                                                                                                                       Page 32 of 32



Document Created: 2016-02-26 10:29:24
Document Modified: 2016-02-26 10:29:24

© 2024 FCC.report