Human Exposure

FCC ID: BKMAE-7122

RF Exposure Info

Download: PDF
FCCID_2551568

                                               Report No.: FR510764




            Appendix C. Maximum Permissible Exposure




FCC ID: BKMAE-7122                            Page No.   : C1 of C3


                                                                                                   Report No.: FR510764



1. Maximum Permissible Exposure
1.1. Applicable Standard

      Systems operating under the provisions of this section shall be operated in a manner that ensures that the
      public is not exposed to radio frequency energy levels in excess limit for maximum permissible exposure.
      In accordance with 47 CFR FCC Part 2 Subpart J, section 2.1091 this device has been defined as a
      mobile device whereby a distance of 0.2 m normally can be maintained between the user and the
      device.
      (A) Limits for Occupational / Controlled Exposure
                                                                                                       Averaging Time
        Frequency Range              Electric Field     Magnetic Field         Power Density (S)
                                                                                                        |E|²,|H|² or S
              (MHz)               Strength (E) (V/m)   Strength (H) (A/m)         (mW/ cm²)
                                                                                                          (minutes)
              0.3-3.0                    614                 1.63                    (100)*                   6
              3.0-30                   1842 / f             4.89 / f                (900 / f)*                6
              30-300                    61.4                 0.163                     1.0                    6
            300-1500                                                                  F/300                   6
          1500-100,000                                                                    5                   6
      (B) Limits for General Population / Uncontrolled Exposure
                                                                                                       Averaging Time
        Frequency Range              Electric Field     Magnetic Field        Power Density (S)
                                                                                                        |E|²,|H|² or S
              (MHz)               Strength (E) (V/m)   Strength (H) (A/m)        (mW/ cm²)
                                                                                                          (minutes)
             0.3-1.34                   614                  1.63                    (100)*                  30
             1.34-30                    824/f                2.19/f                  (180/f)*                30
              30-300                    27.5                 0.073                     0.2                   30
            300-1500                                                                 F/1500                  30
          1500-100,000                                                                 1.0                   30
      Note: f = frequency in MHz ; *Plane-wave equivalent power density

1.2. MPE Calculation Method

      E (V/m) =
                     30  P  G                   Power Density:      Pd (W/m²) =
                                                                                    E2
                         d                                                          377
      E = Electric field (V/m)
      P = Average RF output power (W)
      G = EUT Antenna numeric gain (numeric)
      d = Separation distance between radiator and human body (m)
      The formula can be changed to

      Pd =
              30  P  G
               377  d 2
      From the EUT RF output power, the minimum mobile separation distance, d=0.2m, as well as the gain of
      the used antenna, the RF power density can be obtained.

FCC ID: BKMAE-7122                                                                               Page No.   : C2 of C3


                                                                                         Report No.: FR510764


1.3. Calculated Result and Limit

      Exposure Environment: General Population / Uncontrolled Exposure
      Antenna Type : Printed Antenna
      Conducted Power for IEEE 802.11b: 19.42 dBm
                                              The maximum combined                      Limit of
                                   Antenna                                 Power
       Distance      Antenna                   Average Output Power                      Power
                                    Gain                                 Density (S)                  Test Result
          (m)        Gain (dBi)                                                        Density (S)
                                  (numeric)     (dBm)      (mW)          (mW/cm²)
                                                                                       (mW/cm²)
          0.2          0.32        1.0765      19.4232    87.5638        0.018762          1           Complies