03 FCC DFS Report

FCC ID: BKEHDH002

Test Report

Download: PDF
FCCID_4466023

                                                                                           Test report No.        : 12656071S-X-R1
                                                                                           Page                   : 1 of 22
                                                                                           Issued date            : September 27, 2019
                                                                                           FCC ID                 : BKEHDH002




                                 RADIO TEST REPORT
                                   Test Report No. : 12656071S-X-R1
              Applicant                            :         Nintendo Co., Ltd.
              Type of Equipment                    :         Game console

              Model No.                            :         HDH-002
              FCC ID                               :         BKEHDH002
              Test regulation                      :         FCC Part 15 Subpart E: 2019
                                                             Section 15.407(DFS test only)
              Test Result                          :         Complied (Refer to SECTION 4.2)

 1.       This test report shall not be reproduced in full or partial, without the written approval of UL Japan, Inc.
 2.       The results in this report apply only to the sample tested.
 3.       This sample tested is in compliance with the limits of the above regulation.
 4.       The test results in this test report are traceable to the national or international standards.
 5.       This test report must not be used by the customer to claim product certification, approval, or endorsement by
          the A2LA accreditation body.
 6.       This test report covers Radio technical requirements.
          It does not cover administrative issues such as Manual or non-Radio test related Requirements. (if applicable)
 7.       The all test items in this test report are conducted by UL Japan, Inc. Shonan EMC Lab.
 8.       The opinions and the interpretations to the result of the description in this report are outside scopes where UL
          Japan has been accredited.
 9.       The information provided from the customer for this report is identified in SECTION 1.
 10.      This report is a revised version of 12656071S-X.. 12656071S-X is replaced with this report.

                            Date of test     :                           August 4, 2019

                            Representative test
                            engineer:
                                                                     Kenichi Adachi
                                                                        Engineer
                                                               Consumer Technology Division


                            Approved by :
                                                                      Akio Hayashi
                                                                         Leader
                                                               Consumer Technology Division




                                                                                                                CERTIFICATE 1266.03

       The testing in which "Non-accreditation" is displayed is outside the accreditation scopes in UL Japan.
       There is no testing item of "Non-accreditation".



UL Japan, Inc.
Shonan EMC Lab.
1-22-3 Megumigaoka, Hiratsuka-shi, Kanagawa-ken, 259-1220 JAPAN                  Report Cover Page - 13-EM-F0429 Issue # 15.0
Telephone:       +81 463 50 6400
Facsimile:       +81 463 50 6401


                                                                          Test report No.   : 12656071S-X-R1
                                                                          Page              : 2 of 22
                                                                          Issued date       : September 27, 2019
                                                                          FCC ID            : BKEHDH002




                                  REVISION HISTORY
                             Original Test Report No.: 12656071S-X

Revision       Test report No.       Date               Page revised   Contents
- (Original)   12656071S-X           August 5, 2019     -              -
1              12656071S-X-R1        September 27,      5              Addition of product description as below,
                                     2019                              The EUT is intended to be used for
                                                                       software development or events.




UL Japan, Inc.
Shonan EMC Lab.
1-22-3 Megumigaoka, Hiratsuka-shi, Kanagawa-ken, 259-1220 JAPAN
Telephone:       +81 463 50 6400
Facsimile:       +81 463 50 6401


                                                                                                       Test report No.         : 12656071S-X-R1
                                                                                                       Page                    : 3 of 22
                                                                                                       Issued date             : September 27, 2019
                                                                                                       FCC ID                  : BKEHDH002




CONTENTS                                                                                                                                     PAGE


SECTION 1: Customer information ............................................................................................ 4
SECTION 2: Equipment under test (E.U.T.) .............................................................................. 4
SECTION 3: Scope of Report ....................................................................................................... 6
SECTION 4: Test specification, procedures & results ............................................................... 6
SECTION 5: Operation of E.U.T. during testing........................................................................ 12
SECTION 6: In-Service Monitoring for Channel Move Time, Channel Closing Transmission
Time .................................................................................................................................................. 17
SECTION 7: In-Service Monitoring for Non-Occupancy Period ............................................. 19
APPENDIX 1: Test instruments .................................................................................................... 21
APPENDIX 2: Photographs of test setup...................................................................................... 22




UL Japan, Inc.
Shonan EMC Lab.
1-22-3 Megumigaoka, Hiratsuka-shi, Kanagawa-ken, 259-1220 JAPAN
Telephone:       +81 463 50 6400
Facsimile:       +81 463 50 6401


                                                                               Test report No.   : 12656071S-X-R1
                                                                               Page              : 4 of 22
                                                                               Issued date       : September 27, 2019
                                                                               FCC ID            : BKEHDH002



SECTION 1: Customer information
Company Name                           :    Nintendo Co., Ltd.
Address                                :    11-1 Hokotate-cho, Kamitoba, Minami-ku, Kyoto 601-8501, Japan
Telephone Number                       :    + 81 75 662 9600
Facsimile Number                       :    + 81 75 662 9624
Contact Person                         :    Kazuya Kuramoto

The information provided from the customer is as follows;
- Applicant, Type of Equipment, Model No., FCC ID on the cover and other relevant pages
- Operating/Test Mode(s) (Mode(s)) on all the relevant pages
- SECTION 1: Customer information
- SECTION 2: Equipment under test (E.U.T.)
- SECTION 4: Operation of E.U.T. during testing
* The laboratory is exempted from liability of any test results affected from the above information in SECTION 2 and 4.

SECTION 2: Equipment under test (E.U.T.)
2.1     Identification of E.U.T.
Type of Equipment                  :       Game Console
Model No.                          :       HDH-002
Serial No.                         :       Refer to SECTION 4.2
Rating                             :       DC 3.8 V (battery),
                                           AC Adapter input: AC 100 V - 240 V, 50 Hz / 60 Hz, 1 A,
                                           AC Adapter output: DC 5 V - DC 15 V, 2.6 A
Receipt Date of Sample             :       August 2, 2019
(Information from test lab.)
Country of Mass-production         :       China
Condition of EUT                   :       Engineering prototype
                                           (Not for Sale: This sample is equivalent to mass-produced items.)
Modification of EUT                :       No Modification by the test lab.




UL Japan, Inc.
Shonan EMC Lab.
1-22-3 Megumigaoka, Hiratsuka-shi, Kanagawa-ken, 259-1220 JAPAN
Telephone:       +81 463 50 6400
Facsimile:       +81 463 50 6401


                                                                             Test report No.   : 12656071S-X-R1
                                                                             Page              : 5 of 22
                                                                             Issued date       : September 27, 2019
                                                                             FCC ID            : BKEHDH002



2.2     Product description

Model: HDH-002 (referred to as the EUT in this report) is a Game Console.
The EUT is intended to be used for software development or events.

Radio Specification

Wireless LAN, Bluetooth part:
 Equipment type                    :   Transmitter
 Frequency of operation            :   Wireless LAN part: (2.4 GHz): 2412 MHz - 2472 MHz,
                                       (U-NII-1): 5180 MHz - 5240 MHz,
                                       (U-NII-2A): 5260 MHz - 5320 MHz,
                                       Bluetooth (BDR/EDR/BTLE) part: 2402 MHz - 2480 MHz
 Radio part clock frequency        :   37.4 MHz
 Channel spacing                   :   Wireless LAN part: (2.4 GHz): 5 MHz, (5 GHz): 20 MHz,
                                       Bluetooth part: (BDR/EDR): 1 MHz, (BT LE): 2 MHz
 Type of modulation                :   Wireless LAN part:
                                        2.4 GHz bands: DBPSK, DQPSK, CCK, OFDM,
                                        5 GHz bands: OFDM
                                       Bluetooth (BT) part:
                                        BDR (Basic Data Rate): GFSK,
                                        EDR (Enhanced Data Rate): π/4-DQPSK, 8DPSK,
                                        BT LE (Low Energy mode): GFSK
 Antenna type                      :   Sheet metal antenna
 Antenna connector type            :   (Ant: 0): MHF2, (Ant: 1): MHF2
 Antenna gain                      :   2.4 GHz bands: (Ant: 0): -0.904 dBi, (Ant: 1): -0.730 dBi
                                       5 GHz bands: (Ant: 0): 2.949 dBi, (Ant: 1): 1.994 dBi
 Power Supply (radio part input)   :   DC 1.8 V, DC 3.3 V
 Operation temperature range       :   +5 deg.C to +35 deg.C

Remarks: This wireless module consists of 1 chip each of 5 GHz bands and 2.4 GHz bands.

 NFC part:
 Equipment type                    :   Transmitter
 Frequency of operation            :   13.56 MHz
 Radio part clock frequency        :   27.12 MHz
 Type of modulation                :   ASK
 Power Supply (radio part input)   :   DC 1.8 V, DC 5.0 V
 Antenna type                      :   Ferrite Chip Antenna
 Operation temperature range       :   +5 deg.C to +35 deg.C




UL Japan, Inc.
Shonan EMC Lab.
1-22-3 Megumigaoka, Hiratsuka-shi, Kanagawa-ken, 259-1220 JAPAN
Telephone:       +81 463 50 6400
Facsimile:       +81 463 50 6401


                                                                               Test report No.   : 12656071S-X-R1
                                                                               Page              : 6 of 22
                                                                               Issued date       : September 27, 2019
                                                                               FCC ID            : BKEHDH002



SECTION 3: Scope of Report
The EUT has the channels from 5180 MHz to 5320 MHz.
This report only covers DFS requirement subject to 5250 MHz to 5350 MHz bands, as specified by the following
referenced procedures.



SECTION 4: Test specification, procedures & results

4.1     Test Specification

Test Specification            :   FCC Part 15 Subpart E
                                  FCC Part 15 final revised on June 4, 2019 and effective July 5, 2019 except 15.258

Title                         :   FCC 47CFR Part15 Radio Frequency Device Subpart E
                                  Unlicensed National Information Infrastructure Devices
                                  Section 15.407 General technical requirements




Test Specification                 :       KDB 905462 D02 v02
Title                              :       COMPLIANCE MEASUREMENT PROCEDURES FOR UNILICENSED
                                           -NATIONAL INFORMATION INFRASTRUCTURE DEVICES
                                           OPERATING IN THE 5250 - 5350 MHz AND 5470 - 5725 MHz BANDS
                                           INCORPORATING DYNAMIC FREQUENCY SELECTION




UL Japan, Inc.
Shonan EMC Lab.
1-22-3 Megumigaoka, Hiratsuka-shi, Kanagawa-ken, 259-1220 JAPAN
Telephone:       +81 463 50 6400
Facsimile:       +81 463 50 6401


                                                                                               Test report No.      : 12656071S—X—RI
                                                                                               Page                 :7 of 22
                                                                                               Issued date          : September 27, 2019
                                                                                               FCC ID               : BKEHDHOO2


4.2      Procedures and results

Table 2: Applicability of DFS Requirements

      Requirement                 Operating Mode             Test Procedures &        Deviation          Results
                                  Client without             Limits
                                  Radar Detection
      U—NII Detection             Not required.              FCC, KDB 905462 DO2      N/A                NA
      Bandwidth                                              Section 7.8.1
      Initial Channel             Not required.              FCCLS.407 (hYZ)          NA                 NA

      ?Vallabfl"y Check                                       FCC, KDB 905462 Do2
       me                                                    Section 7.8.2.1
                                                             RSS—247 6.3
      Radar Burst at the          Not required.              FCCL5.407 (i)(Z)         N/A                NA

      Beginning ofthe                                        FCC, KDB 905462 Do2
      Channel Availability                                   Section 7.8.2.2
      Check Time                                         —
                                                             RSS—247 6.3
      Radar Burst at the          Not required.              FCCL3.407                NA                 NA
      Endof the Channel                                      FCC, KDB 905462 Do2
      Availability Check                                     Section 7.8.2.3
      Time                                                   RSS—247 63
      In—Service Monitoring       YeS                        FCCLS.407 (h)Z)          NA                 Complied

      if” Ch“C“]:‘el N;‘“’e                              |Foc, KpB 905462 Doz|                           a
       To      Cbanne                                     Section 7.8.3
      Closing Transmission                               ——                      ——
      Time                                                RSS—247 6.3

      In—Service Monitoring.      Y°s *                   FCCLS.407 (h)Z)      NA                        Complied
      for Non—Occupancy                                  |~                 ==                           5)
                                                          FCC, KDB 905462 DO2
      period
                                                          Section 7.8.3

                                                             RSS—247 6.3
      Statistical                 Not required.          |FoCLs.407)                  NA                 NA
      Performance Check                                      FCC, KDB 905462 DO2
                                                             Section 7.8.4


      *Although this test was not required in FCC, KDB 905462 DO2,it was performed as additional test

      a) Refer to SECTION 6 (data of In—Service Monitoring for Channel Move Time, Channel Closing Transmission Time}
      b) Refer to SECTION 7 (data of In—Service Monitoring for Non—Occupancy Period)
      Symbols
      Complied      The data of this test item has enough margin, more than the measurement uncertainty.
      Complied#       The data of this test item meets the limits unless the measurement uncertainty is taken into consideration.




UL Japan, Inc.
Shonan EMC Lab.
1—22—3 Megumigaoka, Hiratsuka—shi, Kanagawa—ken, 259—1220 JAPAN
Telephone         +81 463 50 6400
Facsimile         +81 463 50 6401


                                                                                      Test report No.     : 12656071S-X-R1
                                                                                      Page                : 8 of 22
                                                                                      Issued date         : September 27, 2019
                                                                                      FCC ID              : BKEHDH002



Table 3: DFS Detection Thresholds for Master Devices and Client Devices With Radar
      Maximum Transmit Power                                     Value (See Notes 1, 2 and 3)
      E.I.R.P. ≥ 200 milliwatt                                   -64 dBm
      E.I.R.P. < 200 milliwatt and                               -62 dBm
      power spectral density < 10dBm/MHz
      E.I.R.P. < 200 milliwatt that do not meet the power        -64 dBm
      spectral density requirement
      Note 1: This is the level at the input of the receiver assuming a 0 dBi receive antenna.
      Note 2: Throughout these test procedures an additional 1 dB has been added to the amplitude of the test
      transmission waveforms to account for variations in measurement equipment. This will ensure that the test
      signal is at or above the detection threshold level to trigger a DFS response.
      Note 3: E.I.R.P. is based on the highest antenna gain. For MIMO devices refer to KDB Publication 662911
      D01.

Table 4: DFS Response Requirement Values
      Parameter                                                     Value
      Non-occupancy period                                          Minimum 30 minutes
      Channel Availability Check Time                               60 seconds
      Channel Move Time                                             10 seconds
                                                                    See Note 1
      Channel Closing Transmission Time                             200 milliseconds + an aggregate of 60
                                                                    milliseconds over remaining 10 second period.
                                                                    See Notes 1 and 2
      U-NII Detection Bandwidth                                     Minimum 100 % of the U-NII 99 % transmission
                                                                    power bandwidth
                                                                    See Note 3
      Note 1: The Channel Move Time and the Channel Closing Transmission Time should be performed with
      Radar Type 0. The measurement timing begins at the end of the Radar Type 0 burst.
      Note 2: The Channel Closing Transmission Time is comprised of 200 milliseconds starting at the beginning
      of the Channel Move Time plus any additional intermittent control signals required to facilitate a Channel
      move (an aggregate of 60 milliseconds) during the remainder of the 10 second period. The aggregate duration
      of control signal will not count quiet periods in between transmissions.
      Note 3: During the U-NII Detection Bandwidth detection test, radar type 0 should be used. For each
      frequency step the minimum percentage of detection is 90 percent. Measurements are performed with no data
      traffic.




UL Japan, Inc.
Shonan EMC Lab.
1-22-3 Megumigaoka, Hiratsuka-shi, Kanagawa-ken, 259-1220 JAPAN
Telephone:       +81 463 50 6400
Facsimile:       +81 463 50 6401


                                                                                      Test report No.     : 12656071S-X-R1
                                                                                      Page                : 9 of 22
                                                                                      Issued date         : September 27, 2019
                                                                                      FCC ID              : BKEHDH002



Table 5 Short Pulse Radar Test Waveform
    Radar Type           Pulse Width          PRI [µs]              Number of Pulses      Minimum              Minimum
                         [µs]                                                             Percentage of        Number of
                                                                                          Successful           Traials
                                                                                          Detection
            0                     1                  1428                     18             See Note 1            See Note 1
            1                     1           Test A: 15 unique          Roundup (              60 %                   30
                                                  PRI values              (1 / 360)
                                              randomly selected       x ( (19 x 10^6 )
                                              from the list of 23    / PRI [micro sec.]
                                                 PRI values in                ))
                                                   Table 5a
                                              Test B: 15 unique
                                                  PRI values
                                              randomly selected
                                              within the range of
                                               518 - 3066 micro
                                                  sec., with a
                                                   minimum
                                                increment of 1
                                                  micro sec.,
                                                excluding PRI
                                              values selected in
                                                    Test A
             2                  1-5                150 - 230              23 - 29               60 %                    30
             3                  6 - 10             200 - 500              16 - 18               60 %                    30
             4                 11 - 20             200 - 500              12 - 16               60 %                    30
    Aggregate (Rader Types 1-4)                                                                 80 %                   120
    Note 1: Short Pulse Radar Type 0 should be used for the detection bandwidth test, channel move time, and channel closing time
    tests.




UL Japan, Inc.
Shonan EMC Lab.
1-22-3 Megumigaoka, Hiratsuka-shi, Kanagawa-ken, 259-1220 JAPAN
Telephone:       +81 463 50 6400
Facsimile:       +81 463 50 6401


                                                                                   Test report No.    : 12656071S-X-R1
                                                                                   Page               : 10 of 22
                                                                                   Issued date        : September 27, 2019
                                                                                   FCC ID             : BKEHDH002




Table 5a Pulse Repetition Interval Values for Test A
    Pulse Repetition        Pulse Repetition Frequency       Pulse Repetition Interval
    Frequency Number        (Pulses Per Second)              (Micro seconds)
             1                          1930.5                          518
             2                          1858.7                          538
             3                          1792.1                          558
             4                          1730.1                          578
             5                          1672.2                          598
             6                          1618.1                          618
             7                          1567.4                          638
             8                          1519.8                          658
             9                          1474.9                          678
             10                         1432.7                          698
             11                         1392.8                          718
             12                          1355                           738
             13                         1319.3                          758
             14                         1285.3                          778
             15                         1253.1                          798
             16                         1222.5                          818
             17                         1193.3                          838
             18                         1165.6                          858
             19                          1139                           878
             20                         1113.6                          898
             21                         1089.3                          918
             22                         1066.1                          938
             23                          326.2                         3066


Table 6 Long Pulse Radar Test Waveform
    Radar Type    Pulse Width     Chip Width    PRI [µs]         Number of      Number of        Minimum         Minimum
                  [µs]            [MHz]                          Pulses per     Burst            Percentage      Number of
                                                                 Burst                           of Successful   Trials
                                                                                                 Detection
          5          50 - 100        5 - 20      1000 - 2000         1-3            8 - 20           80 %             30


Table 7 Frequency Hopping Radar Test Waveform

    Radar Type    Pulse Width     PRI [µs]      Pulse per        Hopping        Hopping          Minimum         Minimum
                  [µs]                          Hop [kHz]        Rate [kHz]     Sequence         Percentage      Number of
                                                                                Length [ms]      of Successful   Trials
                                                                                                 Detection
          6             1             333                9           0.333           300             70 %             30




UL Japan, Inc.
Shonan EMC Lab.
1-22-3 Megumigaoka, Hiratsuka-shi, Kanagawa-ken, 259-1220 JAPAN
Telephone:       +81 463 50 6400
Facsimile:       +81 463 50 6401


                                                                                Test report No.       : 12656071S-X-R1
                                                                                Page                  : 11 of 22
                                                                                Issued date           : September 27, 2019
                                                                                FCC ID                : BKEHDH002



4.3         Test Location

UL Japan, Inc. Shonan EMC Lab.
1-22-3, Megumigaoka, Hiratsuka-shi, Kanagawa-ken 259-1220 JAPAN
Telephone: +81 463 50 6400, Facsimile: +81 463 50 6401
A2LA Certificate Number: 1266.03
FCC Test Firm Registration Number: 626366
                                                                                              Maximum
                       IC Registration Width x Depth x     Size of reference ground plane (m)
Test site                                                                                     measuremen
                       Number          Height (m)          / horizontal conducting plane
                                                                                              t distance
No.1 Semi-anechoic
                       2973D-1        20.6 x 11.3 x 7.65   20.6 x 11.3                            10 m
chamber
No.2 Semi-anechoic
                       2973D-2        20.6 x 11.3 x 7.65   20.6 x 11.3                            10 m
chamber
No.3 Semi-anechoic
                       2973D-3        12.7 x 7.7 x 5.35    12.7 x 7.7                             5m
chamber
No.4 Semi-anechoic
                       -              8.1 x 5.1 x 3.55     8.1 x 5.1                              -
chamber
No.1 Shielded room     -              6.8 x 4.1 x 2.7      6.8 x 4.1                              -
No.2 Shielded room     -              6.8 x 4.1 x 2.7      6.8 x 4.1                              -
No.3 Shielded room     -              6.3 x 4.7 x 2.7      6.3 x 4.7                              -
No.4 Shielded room     -              4.4 x 4.7 x 2.7      4.4 x 4.7                              -
No.5 Shielded room     -              7.8 x 6.4 x 2.7      7.8 x 6.4                              -
No.6 Shielded room     -              7.8 x 6.4 x 2.7      7.8 x 6.4                              -
No.8 shielded room     -              3.45 x 5.5 x 2.4     3.45 x 5.5                             -
No.1 Measurement
                       -              2.55 x 4.1 x 2.5     -                                      -
room


4.4    Uncertainty

The following uncertainties have been calculated to provide a confidence level of 95 % using a coverage factor k = 2.

Time Measurement uncertainty for this test was: (±) 0.012 %


4.5    Test set up, Data of DFS test, and Test instruments of DFS

Refer to APPENDIX.




UL Japan, Inc.
Shonan EMC Lab.
1-22-3 Megumigaoka, Hiratsuka-shi, Kanagawa-ken, 259-1220 JAPAN
Telephone:       +81 463 50 6400
Facsimile:       +81 463 50 6401


                                                                                Test report No.   : 12656071S-X-R1
                                                                                Page              : 12 of 22
                                                                                Issued date       : September 27, 2019
                                                                                FCC ID            : BKEHDH002




SECTION 5: Operation of E.U.T. during testing

5.1     Operating Modes

The EUT, which is a Client Device without Radar detection capability, operates over the 5260 MHz - 5320 MHz.

The EUT uses one transmitter connected to a 50 ohm coaxial antenna ports. The antenna port is connected to the test
system.

WLAN traffic is generated by streaming the ping data with iperf.exe (ver.1.7.0) from the Master to the Client. (Channel
loading was over 17 %)

The EUT utilizes the 802.11a, 802.11n and 802.11ac architecture, with a nominal channel bandwidth.
The EUT had used IEEE 802.11ac VHT80 (widest mode).

The FCC ID for the Master Device used with EUT for DFS testing is LDK102073.

The rated output power of the Master unit is > 200 mW (23 dBm). Therefore the required interference threshold level is
-64 dBm. After correction for antenna gain and procedural adjustments, the required conducted threshold at the antenna
port is - 64 + 1 + 4= -59 dBm (threshold level + additional 1 dB + antenna gain *1)).
*1) Minimum antenna gain of Master Device (FCC ID: LDK102087, IC No.: 2461B-102087)




UL Japan, Inc.
Shonan EMC Lab.
1-22-3 Megumigaoka, Hiratsuka-shi, Kanagawa-ken, 259-1220 JAPAN
Telephone:       +81 463 50 6400
Facsimile:       +81 463 50 6401


                                                                                   Test report No.     : 12656071S-X-R1
                                                                                   Page                : 13 of 22
                                                                                   Issued date         : September 27, 2019
                                                                                   FCC ID              : BKEHDH002


5.2     Configuration and peripherals


                                                            4
          A: EUT            Conducted           C                 E
                             method
                             system


                 1                                      2                 5
                                                    D                 F
             B

                                                        3                 6
      AC120V/60Hz
                                                                                        : Standard Ferrite Core

                                                     AC100V/50Hz


Description of EUT and Support equipment
 No. Item                     Model number                  Serial number              Manufacturer            Remarks
 A     Game Console           HDH-002                       XJW01000025925             Nintendo                EUT
 B     AC Adapter             HAC-002                       -                          Nintendo                -
       Wireless LAN access    AIR-AP1262N-A-                FTX1619E5EZ                Cisco Systems           FCC ID:
 C
       point (Master Device)  K9                                                                               LDK102073
 D     AC Adapter             EADP-18MB                     DAB1528MANP                Cisco Systems           -
       Notebook Computer      DELL Vostro                   29090510205                Dell                    -
 E
                              V1510
 F     AC Adapter             LA65NS1-00                    71615-93B-385D             Dell                    -

List of cables used
 No. Cable Name                           Length (m)                                     Shield
                                                                            Cable                 Connector
 1     DC                                           1.5                   Unshielded              Unshielded
 2     Access Point DC Power                        1.8                   Unshielded              Unshielded
 3     Access Point AC Power                        2.0                   Unshielded              Unshielded
 4     LAN                                          3.0                   Unshielded              Unshielded
 5     DELL PC DC Power                             1.8                   Unshielded              Unshielded
 6     DELL PC AC Power                             0.7                   Unshielded              Unshielded




UL Japan, Inc.
Shonan EMC Lab.
1-22-3 Megumigaoka, Hiratsuka-shi, Kanagawa-ken, 259-1220 JAPAN
Telephone:       +81 463 50 6400
Facsimile:       +81 463 50 6401


                                                                                       Test report No.        : 12656071S-X-R1
                                                                                       Page                   : 14 of 22
                                                                                       Issued date            : September 27, 2019
                                                                                       FCC ID                 : BKEHDH002



5.3      Test and Measurement System

SYSTEM OVERVIEW

The measurement system is based on a conducted test method.

The software selects waveform parameters from within the bounds of the signal type on a random basis using uniform
distribution. The short pulse types 2, 3, and 4, the long pulse type 5, and the frequency hopping type 6 parameters are
randomized at run-time.

The signal monitoring equipment consists of a spectrum analyzer with the capacity to display 8001 bins on the
horizontal axis. A time-domain resolution of 2 ms/bin is achievable with a 16 seconds sweep time, meeting the 10
seconds short pulse reporting criteria. The aggregate ON time is calculated by multiplying the number of bins above a
threshold during a particular observation period by the dwell time per bin, with the analyzer set to peak detection. A
time-domain resolution of 3 ms/bin is achievable with a 24 seconds sweep time, meeting the 22 seconds long pulse
reporting criteria and allowing a minimum of 10 seconds after the end of the long pulse waveform.


FREQUENCY HOPPING RADAR WAVEFORM GENERATING SUBSYSTEM

The first 100 frequencies are selected out of the hopping sequence of the randomized 475 hop frequencies.
Only a Burst that has the frequency falling within the receiver bandwidth of the tested U-NII device is selected among
those frequencies. (Frequency-domain simulation). The radar waveform generated at the start time of the selected Burst
(Time-domain simulation) is download to the Signal Generator.
If all of the randomly selected 100 frequencies do not fall within the receiver bandwidth of the U-NII device, the radar
waveform is not used for the test.

CONDUCTED METHODS SYSTEM BLOCK DIAGRM
                                                                                                                                              v
       To Spectrum Analyzer
       10 MHz out


                              Signal Generator   Notebook
                                                 Computer



                                                                                                                             D        D:
                                                                                                                  Power
                                                 PowerDivider        Power            Attenuator Attenuator     Splitters/   E
                                                 DC to 26.5 GHz    Splitters/          (20 dB)      (20 dB)     Combiners
                                                                                                                                     Master
                                                                   Combiners
                              B   Attenuator                                                                                     A
                                  (10 dB)
                                                                                  C

  A:
                        Power
   EUT                  Splitters/
                        Combiners
  (Client)

                                                                                                     Spectrum Analyzer
                                                                        From Signal Generator
                                                                        10 MHz in




MEASUREMENT SYSTEM FREQUENCY REFERENCE

Lock the signal generator and the spectrum analyzer to the same reference sources as follows: Connect the 10 MHz
OUT on the signal generator to the 10 MHz IN on the spectrum analyzer and set the spectrum analyzer 10 MHz In to On.




UL Japan, Inc.
Shonan EMC Lab.
1-22-3 Megumigaoka, Hiratsuka-shi, Kanagawa-ken, 259-1220 JAPAN
Telephone:       +81 463 50 6400
Facsimile:       +81 463 50 6401


                                                                                  Test report No.    : 12656071S-X-R1
                                                                                  Page               : 15 of 22
                                                                                  Issued date        : September 27, 2019
                                                                                  FCC ID             : BKEHDH002



SYSTEM CALIBRATION

Step 1: Set the system as shown in Figure 4 of KDB 905462 D02 7.2.3.

Step 2: Adjust each attenuator to fulfill the following three conditions:
         - WLAN can be communicated, and
         - Rader detection threshold level is bigger than Client Device traffic level on the spectrum analyzer, and
         - Master Device traffic level is not displayed on the spectrum analyzer.

Step 3: Terminate 50 ohm at B, C, D and E points, and connect the spectrum analyzer to the point A.
(See the figure on Section 5.3)
At the point A, adjust the signal generator and spectrum analyzer to the center frequency of the channel to be measured.
Download the applicable radar waveforms to the signal generator. Select the radar waveform, trigger a burst manually
and measure the amplitude on the spectrum analyzer. Readjust the amplitude of the signal generator as required so that
the peak level of the waveform is at a displayed level equal to the required or desired interference detection threshold.
Separate signal generator amplitude settings are determined as required for each radar type.

Step 4: Without changing any of the instrument settings, restore the system setting to Step 2 and adjust the Reference
Level Offset of the spectrum analyzer to the level at Step 3.

By taking the above steps 1 to 4, the spectrum analyzer displays the level of the signal generator as received at the
antenna ports of the Master Device.

See Clause 5.4 for Plots of Noise, Rader Waveforms, and WLAN signals.


5.4      Plots of Noise, Rader Waveforms, and WLAN signals


Plots of System Noise Floor




It was confirmed that the EUT did not transmit before having received appropriate control signals from a Master Device.




UL Japan, Inc.
Shonan EMC Lab.
1-22-3 Megumigaoka, Hiratsuka-shi, Kanagawa-ken, 259-1220 JAPAN
Telephone:       +81 463 50 6400
Facsimile:       +81 463 50 6401


                                                                  Test report No.   : 12656071S-X-R1
                                                                  Page              : 16 of 22
                                                                  Issued date       : September 27, 2019
                                                                  FCC ID            : BKEHDH002


Plots of Radar Waveforms
Rader Type 0




Plots of WLAN Traffic




UL Japan, Inc.
Shonan EMC Lab.
1-22-3 Megumigaoka, Hiratsuka-shi, Kanagawa-ken, 259-1220 JAPAN
Telephone:       +81 463 50 6400
Facsimile:       +81 463 50 6401


                                                                                Test report No.   : 12656071S-X-R1
                                                                                Page              : 17 of 22
                                                                                Issued date       : September 27, 2019
                                                                                FCC ID            : BKEHDH002



SECTION 6: In-Service Monitoring for Channel Move Time, Channel Closing Transmission
Time
6.1     Operating environment

Test place                : No.3 Shielded room
Temperature               : 25 deg.C
Humidity                  : 48 %RH


6.2      Test Procedure

Transfer files from the Master Device to the Client Device on the tested channel during the entire period of the test.
The Radar Waveform generator sends a Burst of pulses for one of the Short Pulse Radar Types 0 at levels defined ,
on the Operating Channel. An additional 1 dB is added to the radar test signal to ensure it is at or above the DFS
Detection Threshold, accounting for equipment variations/errors.
Observe the transmissions of the EUT at the end of the radar Burst on the Operating Channel for duration greater than
10 seconds.


6.3     Test data

         Test Item              Unit        Measurement Time         Limit       Results

  Channel Move Time *1)          [s]               0.060             10.000       Pass
     Channel Closing
  Transmission Time *2)         [ms]                 0                 60         Pass

*1) Channel Move Time is calculated as follows:
    (Channel Move Time) = (End of Transmission) - (End of Burst)

*2) Channel Closing Transmission Time is calculated from (End of Burst + 200 ms) to (End of Burst + 10 s)
    (Channel Closing Transmission Time) = (Number of analyzer bins showing transmission) x (dwell time per bin)
                                        = 0 x 2 [ms]




UL Japan, Inc.
Shonan EMC Lab.
1-22-3 Megumigaoka, Hiratsuka-shi, Kanagawa-ken, 259-1220 JAPAN
Telephone:       +81 463 50 6400
Facsimile:       +81 463 50 6401


                                                                   Test report No.   : 12656071S-X-R1
                                                                   Page              : 18 of 22
                                                                   Issued date       : September 27, 2019
                                                                   FCC ID            : BKEHDH002



Radar Type 0




Marker 1: End of Burst                     : 0.496 s
Marker 1 delta: End of Transmission        : 0.060 s
Marker 2: End of Burst + 200 ms            : 0.696 s




                                End of Burst




                                 End of Transmission




6.4      Test result

Test result: Pass

Date : August 4, 2019             Test engineer : Kenichi Adachi




UL Japan, Inc.
Shonan EMC Lab.
1-22-3 Megumigaoka, Hiratsuka-shi, Kanagawa-ken, 259-1220 JAPAN
Telephone:       +81 463 50 6400
Facsimile:       +81 463 50 6401


                                                                                      Test report No.    : 12656071S-X-R1
                                                                                      Page               : 19 of 22
                                                                                      Issued date        : September 27, 2019
                                                                                      FCC ID             : BKEHDH002



SECTION 7: In-Service Monitoring for Non-Occupancy Period
7.1      Operating environment

Test place                  : No.3 Shielded room
Temperature                 : 25 deg.C
Humidity                    : 48 %RH

7.2      Test Procedure

The following two tests are performed:

1). Transfer files from the Master Device to the Client Device on the tested channel during the entire period of the test.
The Radar Waveform generator sends a Burst of pulses for one of the Radar Types 0 at levels defined
on the Operating Channel. An additional 1 dB is added to the radar test signal to ensure it is at or above the DFS
Detection Threshold, accounting for equipment variations/errors.
Observe the transmissions of the EUT after the Channel Move Time on the Operating Channel for duration greater than
30 minutes.

2). Transfer files from the Master Device to the Client Device on the tested channel during the entire period of the test.
Observe the transmissions of the EUT on the Operating Channel for duration greater than 30 minutes
after the Master Device is shut off.

7.3      Test data
1).Radar Type 0




Marker 1 : End of Burst                        : 22.32 s
Marker 2 : End of Burst + 10 s                 : 32.32 s

* Measurement non-occupancy period: 31.46 minutes or more (1920 [s] – 32.32 [s] = 1887.68 [s] = 31.46 [minutes])




UL Japan, Inc.
Shonan EMC Lab.
1-22-3 Megumigaoka, Hiratsuka-shi, Kanagawa-ken, 259-1220 JAPAN
Telephone:       +81 463 50 6400
Facsimile:       +81 463 50 6401


                                                                                     Test report No.     : 12656071S-X-R1
                                                                                     Page                : 20 of 22
                                                                                     Issued date         : September 27, 2019
                                                                                     FCC ID              : BKEHDH002



2).Master is shut off




Marker 1 : End of Burst                        : 23.52 s

* Measurement non-occupancy period: 31.61 minutes or more (1920 [s]– 23.52 [s] = 1896.48 [s] = 31.61 [minutes])


7.4      Test result

Test result: Pass

Date : August 4, 2019                 Test engineer : Kenichi Adachi




UL Japan, Inc.
Shonan EMC Lab.
1-22-3 Megumigaoka, Hiratsuka-shi, Kanagawa-ken, 259-1220 JAPAN
Telephone:       +81 463 50 6400
Facsimile:       +81 463 50 6401


                                                                                                Test report No.         : 12656071S-X-R1
                                                                                                Page                    : 21 of 22
                                                                                                Issued date             : September 27, 2019
                                                                                                FCC ID                  : BKEHDH002




APPENDIX 1: Test instruments

Test Equipment
                                                                                                                Last                 Calibration
                                                                                                                         Calibration
  Local ID    T est Name LIMS ID      Description         Manufacturer               Model          Serial   Calibration              Interval
                                                                                                                          Due Date
                                                                                                                Date                  (Month)
COT S-SDFS-                        Signal Studio
              DFS       144863                      AGILENT                 N7620A-101          5010-7739 -                -           -
01                                 Software for DFS
SAT 10-16     DFS       160494     Attenuator       Weinschel Corp.         54A-10              83406        2018/12/6     2019/12/30 12
SAT 20-12     DFS       160495     Attenuator          Weinschel Corp.      54A-20              86752        2018/12/6     2019/12/30 12
SAT 20-13     DFS       160496     Attenuator          Weinschel Corp.      54A-20              87636        2018/12/6     2019/12/30 12
SCC-G13       DFS       145166     Coaxial Cable       Suhner               SUCOFLEX 102        31599/2      2018/12/25 2019/12/31 12
SCC-G24       DFS       145181     Coaxial Cable       Suhner               141PE               -            2019/7/4      2020/7/31   12
SCC-G25       DFS       145182     Coaxial Cable       Suhner               141PE               -            2019/7/4      2020/7/31   12
SCC-G26       DFS       145041     Coaxial Cable       Suhner               141PE               -            2019/7/4      2020/7/31   12
                                                                            MWX241-             OCT -09-
SCC-G32       DFS       145183     Coaxial Cable       Junkosha                                              2018/11/25 2019/11/30 12
                                                                            02000KMSKMS         13-005
                                                                            MWX241-
SCC-G37       DFS       151614     Coaxial Cable       Junkosha                                 1612Q035 2018/12/25 2019/12/31 12
                                                                            01000KMSKMS/B
                                   Humidity
SOS-06        DFS       146294                         A&D                  AD-5681             4062118      2018/12/5     2019/12/31 12
                                   Indicator
SPD-01        DFS       146261     Power Divider       AGILENT              11636B              56998        2019/4/16     2020/4/30   12
                                   Power
SPSC-04       DFS       146273     Splitters/Combine   Mini-Circuits        ZN4PD1-63-S+        -            2019/7/5      2020/7/31   12
                                   rs
                                   Power
SPSC-08       DFS       146277     Splitters/Combine   Mini-Circuits        ZFSC-2-10G+         -            2019/7/5      2020/7/31   12
                                   rs
                                   Power
SPSC-14       DFS       157772     Splitters/Combine   Mini-Circuits        ZFSC-2-10G-S+       -            2018/8/12     2019/8/31   12
                                   rs
                                   Wireless LAN                                                 FT X18227
SRE-157       DFS       145693                         Cisco Systems        AIR-CAP3702E-A-K9             -                -           -
                                   access point                                                 609
                                   Spectrum                                                     MY482501
SSA-02        DFS       145800                         AGILENT              E4448A                        2019/4/4         2020/4/31   12
                                   Analyzer                                                     06
                                                                                                MY472715
SSG-01        DFS       145804     Signal Generator    AGILENT              E4438C                        2019/4/23        2020/4/30   12
                                                                                                84
                                                       Weinschel - API
ST M-G7       DFS       171614     T erminator                              M1459A              88995        2019/7/4      2020/7/31   12
                                                       T echnologies Corp
ST S-03       DFS       146210     Digital Hitester    HIOKI                3805-50             80997823     2018/10/16 2019/10/31 12


The expiration date of the calibration is the end of the expired month.
As for some calibrations performed after the tested dates, those test equipment have been controlled by means of
an unbroken chains of calibrations.

All equipment is calibrated with valid calibrations. Each measurement data is traceable to the national or
international standards.
 Test Item:
   DFS: Dynamic Frequency Selection




UL Japan, Inc.
Shonan EMC Lab.
1-22-3 Megumigaoka, Hiratsuka-shi, Kanagawa-ken, 259-1220 JAPAN
Telephone:       +81 463 50 6400
Facsimile:       +81 463 50 6401



Document Created: 2019-09-30 09:13:28
Document Modified: 2019-09-30 09:13:28

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC