Test Report

FCC ID: BJ4-WLTX313-A

Test Report

Download: PDF
FCCID_4343631

                                                                                                                                             2/F., Garment Centre,
                                                                                                                                             576 Castle Peak Road, Kowloon,
                                                                                                                                             Hong Kong.

                                                                                                                                             Telephone:    (852) 2173 8888
                                                                                                                                             Facsimile:    (852) 2785 5487
                                                                                                                                             www.intertek.com




TEST REPORT

Report No.: 18121037HKG-004

HeathCo LLC


FCC ID: BJ4-WLTX313-A
(Application for Class II Permissive Change of 47 Part 15 Certification)

IC: 3984A-WLTX313A
(Class II Permissive Change of RSS-210 Issue 9 Equipment Certification)


Transmitter




Prepared and Checked by:                                                                            Approved by:

                                                                                                                        Digitally signed
                                                                                                                        by Kenneth
                                                                                                                        Wong
                                                                                                                        Location: Intertek
                                                                                                                        Testing Services
                                                                                                                        Hong Kong Ltd.
Signed On File
Wong Cheuk Ho, Herbert                                                                              Wong Kwok Yeung, Kenneth
Lead Engineer                                                                                       Senior Lead Engineer
                                                                                                    Date: July 02, 2019




Intertek’s standard Terms and Conditions can be obtained at our website http://www.intertek.com/terms/.
The test report only allows to be revised within the retention period unless further standard or the requirement was noticed.
This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited
to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or
damage occasioned by the use of this report. Only the Client is authorized to permit copying or distribution of this report and then only in its entirety. Any use of the Intertek
name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results
in this report are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or has ever been under an Intertek certification
program.
© 2017 Intertek

                                                                                  Page 1 of 22


                                                                  HeathCo LLC
                                                                  Intertek Report No:
                                                                  18121037HKG-004.doc




TEST REPORT

GENERAL INFORMATION

Grantee:                    HeathCo LLC
Grantee Address:            2445 Nashville Road, Bowling Green, KY. 42101
Contact Person:             Jeff Bessinger
Tel:                        270-846-8271
Fax:                        N/A
e-mail:                     jbessinger@heathcollc.com
Manufacturer:               HeathCo LLC
Manufacturer Address:       2445 Nashville Road, Bowling Green, KY. 42101
Brand Name:                 Heath, HeathCo, Heath/Zenith
Model / HVIN:               WLTX-313-A
PMN:                        WLTX-313-A
Type of EUT:                Transmitter
Description of EUT:         Wireless Door Chime Transmitter
Serial Number:              N/A
FCC ID / IC:                BJ4-WLTX313-A / 3984A-WLTX313A
Date of Sample Submitted:   June 28, 2019
Date of Test:               June 28, 2019 to July 02, 2019
Report No.:                 18121037HKG-004
Report Date:                July 02, 2019
Environmental Conditions:   Temperature: +10 to 40°C
                            Humidity: 10 to 90%
Conclusion:                 Test was conducted by client submitted sample. The submitted
                            sample as received complied with the 47 CFR Part 15 / RSS-210
                            Issue 9 Certification.




                                     Page 2 of 22


                                                                               HeathCo LLC
                                                                               Intertek Report No:
                                                                               18121037HKG-004.doc




TEST REPORT

SUMMARY OF TEST RESULT

 Test Specification                                 Reference                            Results
 Transmitter Field Strength,                        15.231(a), (b), (c) /                Pass
 Bandwidth and Timing Requirement                   RSS-210 A1.1.1

The equipment under test is found to be complying with the following standards:
FCC Part 15, October 1, 2017 Edition
RSS-210 Issue 9, August 2016
RSS-Gen Issue 5 + Amendment 1, March 2019




Note: 1. The EUT uses a permanently attached antenna which, in accordance to section 15.203, is
         considered sufficient to comply with the pervisions of this section.
      2. Pursuant to FCC part 15 Section 15.215(c), the 20 dB bandwidth of the emission was contained
         within the frequency band designated (mentioned as above) which the EUT operated. The
         effects, if any, from frequency sweeping, frequency hopping, other modulation techniques and
         frequency stability over excepted variations in temperature and supply voltage were considered.


                                              Page 3 of 22


                                                                                                           HeathCo LLC
                                                                                                           Intertek Report No:
                                                                                                           18121037HKG-004.doc




TEST REPORT
TABLE OF CONTENTS

1.0    GENERAL DESCRIPTION ................................................................................................ 5

       1.1      Product Description ...................................................................................................5
       1.2      Purpose of Change .....................................................................................................5
       1.3      Test Methodology ......................................................................................................5
       1.4      Test Facility ................................................................................................................5

2.0    SYSTEM TEST CONFIGURATION ..................................................................................... 6

       2.1      Justification ................................................................................................................6
       2.2      EUT Exercising Software.............................................................................................6
       2.3      Special Accessories ....................................................................................................6
       2.4      Measurement Uncertainty.........................................................................................6
       2.5      Support Equipment List and Description ....................................................................6

3.0    EMISSION RESULTS....................................................................................................... 7

       3.1      Field Strength Calculation ..........................................................................................7
       3.2      Radiated Emission Configuration Photograph............................................................8
       3.3      Radiated Emission Data .............................................................................................8

4.0    EQUIPMENT PHOTOGRAPHS ...................................................................................... 10

5.0    PRODUCT LABELLING.................................................................................................. 10

6.0    TECHNICAL SPECIFICATIONS ....................................................................................... 10

7.0    INSTRUCTION MANUAL .............................................................................................. 10

8.0    MISCELLANEOUS INFORMATION ................................................................................ 11

       8.1      Measured Bandwidth ..............................................................................................12
       8.2      Discussion of Pulse Desensitization ..........................................................................13
       8.3      Calculation of Average Factor ..................................................................................13
       8.4      Emissions Test Procedures .......................................................................................17
       8.5      Occupied Bandwidth ................................................................................................20

9.0    CONFIDENTIALITY REQUEST ....................................................................................... 21

10.0   EQUIPMENT LIST ........................................................................................................ 21


                                                             Page 4 of 22


                                                                                     HeathCo LLC
                                                                                     Intertek Report No:
                                                                                     18121037HKG-004.doc




TEST REPORT

1.0   GENERAL DESCRIPTION

1.1   Product Description

      The Equipment Under Test (EUT) is a Wireless Door Chime Transmitter (315MHz Wireless push
      button). When the button of the EUT is activated, the corresponding 315MHz remote door bell
      receiver (Wireless Plug-in Chime) will sound. No battery is needed as the EUT is powered by the
      electro-motive force generated by the induction coil activated by mechanical bouncing energy at
      the releasing moment of the push button. The EUT will be deactivated after the button bouncing.

      Antenna Type: Internal, Integral

      For electronic filing, the brief circuit description is saved with filename: descri.pdf.


1.2   Purpose of Change

      The changes that are made on new model from the original certified model.
      - Main PCB layout - Cost reduction after new PCB layout (no quality impact)
      - Antenna matching circuit – RC components values for better matching

      Therefore, the purpose of this application is to report changes in the original certified product. The
      RF portion and its power setting are remained the same, and other designs including electrical,
      electronic and mechanical are identical.


1.3   Test Methodology

      Radiated emission measurements were performed according to the procedures in ANSI C63.10
      (2013). All radiated measurements were performed in an 3m Chamber. Preliminary scans
      were performed in the 3m Chamber only to determine worst case modes. All radiated tests
      were performed at an antenna to EUT distance of 3 meters, unless stated otherwise in the
      “Justification Section” of this Application.


1.4   Test Facility

      The 3m Chamber used to collect the radiated data is located at Workshop No. 3, G/F., World-
      Wide Industrial Centre, 43-47 Shan Mei Street, Fo Tan, Sha Tin, N.T., Hong Kong. This test facility
      and site measurement data have been placed on file with the FCC and IC No. 2042H.




                                                 Page 5 of 22


                                                                               HeathCo LLC
                                                                               Intertek Report No:
                                                                               18121037HKG-004.doc




TEST REPORT
2.0   SYSTEM TEST CONFIGURATION
2.1   Justification

      The system was configured for testing in a typical fashion (as a customer would normally use it),
      and in the confines as outlined in ANSI C63.10 (2013).

      The device was powered by 3.0V DC power supply during test.

      For maximizing emissions, the EUT was rotated through 360°, the antenna height was varied from
      1 meter to 4 meters above the ground plane, and the antenna polarization was changed. This
      step by step procedure for maximizing emissions led to the data reported in Exhibit 3.0.

      The unit was operated standalone and placed in the center of the turntable.

      The equipment under test (EUT) was configured for testing in a typical fashion (as a customer
      would normally use it). The EUT was mounted to a plastic stand if necessary and placed on the
      wooden turntable, which enabled the engineer to maximize emissions through its placement in
      the three orthogonal axes.


2.2   EUT Exercising Software

      There was no special software to exercise the device. Once the unit is powered up, it transmits the
      RF signal continuously.


2.3   Special Accessories

      There are no special accessories necessary for compliance of this product.


2.4   Measurement Uncertainty

      When determining of the test conclusion, the Measurement Uncertainty of test has been
      considered.


2.5   Support Equipment List and Description

      N/A.




                                               Page 6 of 22


                                                                              HeathCo LLC
                                                                              Intertek Report No:
                                                                              18121037HKG-004.doc




TEST REPORT

3.0   EMISSION RESULTS

      Data is included of the worst case configuration (the configuration which resulted in the highest
      emission levels). A sample calculation, configuration photographs and data tables of the
      emissions are included.


3.1   Field Strength Calculation

      The field strength is calculated by adding the Antenna Factor and Cable Factor, and subtracting
      the Amplifier Gain (if any), Average Factor (optional) from the measured reading. The basic
      equation with a sample calculation is as follows:
      FS = RA + AF + CF - AG - AV
      where FS = Field Strength in dBµV/m
                     RA = Receiver Amplitude (including preamplifier) in dBµV
                     CF = Cable Attenuation Factor in dB
                     AF = Antenna Factor in dB
                     AG = Amplifier Gain in dB
                     AV = Average Factor in dB

      In the following table(s), the reading shown on the data table reflects the preamplifier gain. An
      example for the calculations in the following table is as follows:
      FS = RR + LF
      where          FS = Field Strength in dBµV/m
                     RR = RA - AG - AV in dBµV
                     LF = CF + AF in dB

      Assume a receiver reading of 52.0 dBµV is obtained. The antenna factor of 7.4 dB and cable
      factor of 1.6 dB are added. The amplifier gain of 29 dB and average factor of 5 dB are
      subtracted, giving a field strength of 32 dBµV/m. This value in dBµV/m was converted to its
      corresponding level in µV/m.

      RA = 52.0 dBµV/m
      AF = 7.4 dB                          RR = 18.0 dBµV
      CF = 1.6 dB                          LF = 9.0 dB
      AG = 29.0 dB
      AV = 5.0 dB
      FS = RR + LF
      FS = 18 + 9 = 27 dBµV/m

      Level in µV/m = Common Antilogarithm [(27 dBµV/m)/20] = 22.4 µV/m




                                             Page 7 of 22


                                                                               HeathCo LLC
                                                                               Intertek Report No:
                                                                               18121037HKG-004.doc




TEST REPORT
3.2   Radiated Emission Configuration Photograph

      The worst case in radiated emission was found at 315.005 MHz

      For electronic filing, the worst case radiated emission configuration photographs are saved with
      filename: radiated photos.pdf.


3.3   Radiated Emission Data

      The data on the following page lists the significant emission frequencies, the limit and the margin
      of compliance. Numbers with a minus sign are below the limit.

      Judgment: Passed by 18.7 dB




                                              Page 8 of 22


                                                                                 HeathCo LLC
                                                                                 Intertek Report No:
                                                                                 18121037HKG-004.doc




TEST REPORT

RADIATED EMISSIONS
Model: WLTX-313-A
Date of Test: July 02, 2019
Worst-Case Operating Mode: Transmitting

                                              Table 1
               Pursuant to FCC Part 15 Section 15.231(a) / RSS-210 A1.1 Requirement

                                                                           Average
                                          Pre-   Antenna Average (Average) Limit at
            Polari-   Frequency Reading   Amp     factor  Factor Net at 3m   3m       Margin
            zation      (MHz)   (dBµV)    (dB)     (dB)    (dB)  (dBµV/m) (dBµV/m)      (dB)
              H        315.005   63.2      16      23.0    13.3    56.9     75.6       -18.7
              H        630.008   27.8      16      29.0    13.3    27.5     55.6       -28.1
              V        945.018   27.2      16      33.0    13.3    30.9     55.6       -24.7
              H       1260.000   46.7      34      26.1    13.3    25.5     55.6       -30.1
              H       1575.000   47.0      34     27.2    13.3     26.9     54.0      -27.1
              H       1890.000   56.9      34      27.2    13.3    36.8     55.6       -18.8
              V       2205.000   53.0      34     29.4    13.3     35.1     54.0      -18.9
              V       2520.000    52.2     34      30.4    13.3     35.3     55.6      -20.3
              H       2835.000   52.0      34     30.4    13.3     35.1     54.0      -18.9
              H       3150.000   48.9      34      31.9    13.3     33.5     55.6      -22.1

NOTES:   1. Peak Detector Data unless otherwise stated.

         2. All measurements were made at 3 meters. Harmonic emissions not detected at the 3-
            meter distances were measured at 0.3-meter and an inverse proportional extrapolation
            was performed to compare the signal level to the 3-meter limit. No other harmonic
            emissions than those reported were detected at a test distance of 0.3-meter.

         3. Negative sign in the column shows value below limit.

         4. Horn antenna is used for the emission over 1000MHz.

         5. Emission (the row indicated by bold italic) within the restricted band meets the requirement
            of FCC Part 15 Section 15.205 / RSS-210 4.1.

         6. Measurement Uncertainty is ±5.3dB at a level of confidence of 95%.




                                                 Page 9 of 22


                                                                              HeathCo LLC
                                                                              Intertek Report No:
                                                                              18121037HKG-004.doc




TEST REPORT

4.0   EQUIPMENT PHOTOGRAPHS

      For electronic filing, the photographs are saved with filename: external photos.pdf and internal
      photos.pdf.


5.0   PRODUCT LABELLING

      For electronics filing, the FCC ID label artwork and the label location are saved with filename:
      label.pdf.


6.0   TECHNICAL SPECIFICATIONS

      For electronic filing, the block diagram and schematic of the tested EUT are saved with filename:
      block.pdf and circuit.pdf respectively.


7.0   INSTRUCTION MANUAL

      For electronic filing, a preliminary copy of the Instruction Manual is saved with filename:
      manual.pdf.

      This manual will be provided to the end-user with each unit sold/leased in the United States and
      Canada.




                                             Page 10 of 22


                                                                              HeathCo LLC
                                                                              Intertek Report No:
                                                                              18121037HKG-004.doc




TEST REPORT

8.0   MISCELLANEOUS INFORMATION

      The miscellaneous information includes details of the test procedure and measured bandwidth /
      calculation of factor such as pulse desensitization and averaging factor (calculation and timing
      diagram).

      Timing Plot – Pursuant to FCC Part 15 Section 15.231(a1)- A manually operated transmitter shall
      employ a switch that will automatically deactivate the transmitter within not more than 5 seconds
      of being released.

      Result: Transmission Duration = 24ms (within 5 seconds - Pass)




                                             Page 11 of 22


                                                                      HeathCo LLC
                                                                      Intertek Report No:
                                                                      18121037HKG-004.doc




TEST REPORT
8.1   Measured Bandwidth

      The plot shows the fundamental emission when modulated. From the plot, the bandwidth is
      observed to be 31.8Hz, at 20dBc where the bandwidth limit is 787.5kHz.




                                         Page 12 of 22


                                                                                HeathCo LLC
                                                                                Intertek Report No:
                                                                                18121037HKG-004.doc




TEST REPORT
8.2   Discussion of Pulse Desensitization

      Pulse desensitivity is not applicable for this device. The effective period (Teff) is approximately
      21.648ms for a digital “1” bit which illustrated on technical specification, with a resolution
      bandwidth (3dB) of 1MHz, so the pulse desensitivity factor is 0dB.


8.3   Calculation of Average Factor

      The duty cycle is simply the on-time divided by the period:

      The duration of one cycle = 100ms

      Effective period of the cycle = 4 x 4.8ms + 1 x 2.4ms + 1 x 48µs = 21.648ms

      DC = 21.648 / 100 = 0.21648ms

      Therefore, the averaging factor is found by 20log 0.21648 = -13.3dB.




                                              Page 13 of 22


                                 HeathCo LLC
                                 Intertek Report No:
                                 18121037HKG-004.doc




TEST REPORT

AVERAGE FACTOR




                 Page 14 of 22


                                 HeathCo LLC
                                 Intertek Report No:
                                 18121037HKG-004.doc




TEST REPORT

AVERAGE FACTOR




                 Page 15 of 22


                                 HeathCo LLC
                                 Intertek Report No:
                                 18121037HKG-004.doc




TEST REPORT

AVERAGE FACTOR




                 Page 16 of 22


                                                                               HeathCo LLC
                                                                               Intertek Report No:
                                                                               18121037HKG-004.doc




TEST REPORT
8.4   Emissions Test Procedures

      The following is a description of the test procedure used by Intertek Testing Services Hong Kong
      Ltd. in the measurements of transmitter operating under the Part 15, Subpart C rules.

      The transmitting equipment under test (EUT) is placed on a wooden turntable which is four feet in
      diameter and approximately 0.8m in height above the ground plane for emission measurement at
      or below 1GHz and 1.5m in height above the ground plane for emission measurement above
      1GHz. During the radiated emissions test, the turntable is rotated and any cables leaving the EUT
      are manipulated to find the configuration resulting in maximum emissions. The EUT is adjusted
      through all three orthogonal axis to obtain maximum emission levels. The antenna height and
      polarization are also varied during the testing to search for maximum signal levels. The height of
      the antenna is varied from one to four meters.

      Detector function for radiated emissions is in peak mode. Average readings, when required, are
      taken by measuring the duty cycle of the equipment under test and subtracting the corresponding
      amount in dB from the measured peak readings. A detailed description for the calculation of the
      average factor can be found in Exhibit 8.3.

      The frequency range scanned is from the lowest radio frequency signal generated in the device
      which is greater than 9 kHz to the tenth harmonic of the highest fundamental frequency or 40
      GHz, whichever is lower.




                                             Page 17 of 22


                                                                               HeathCo LLC
                                                                               Intertek Report No:
                                                                               18121037HKG-004.doc




TEST REPORT
8.4   Emissions Test Procedures (cont’d)

      The EUT is warmed up for 15 minutes prior to the test.

      AC power to the unit is varied from 85% to 115% nominal and variation in the fundamental
      emission field strength is recorded. If battery powered, a new, fully charged battery is used.

      Conducted measurements were made as described in ANSI C63.10 (2013).

      The IF bandwidth used for measurement of radiated signal strength was 100 kHz or greater when
      frequency is below 1000 MHz. Where pulsed transmissions of short enough pulse duration
      warrant, a greater bandwidth is selected according to the recommendations of Hewlett Packard
      Application Note 150-2. A discussion of whether pulse desensitivity is applicable to this unit is
      included in this report (See Exhibit 8.1). Above 1000 MHz, a resolution bandwidth of 3 MHz is
      used.

      Transmitter measurements are normally conducted at a measurement distance of three
      meters. However, to assure low enough noise floor in the forbidden bands and above 1 GHz,
      signals are acquired at a distance of one meter or less. All measurements are extrapolated to three
      meters using inverse scaling, unless otherwise reported. Measurements taken at a closer
      distance are so marked.




                                             Page 18 of 22


                                                                                   HeathCo LLC
                                                                                   Intertek Report No:
                                                                                   18121037HKG-004.doc




TEST REPORT
8.4.1   Radiated Emission Test Setup

        The figure below shows the test setup, which is utilized to make these measurements.


                                                                     Antenna
                                                    1.0~4.0m         Tower


                                          3m                              Receiver
                                                                          Antenna
                            E
                            U
                            T




             0.8m

                    Ground Plane
         3m Chamber                                       □

                                                                    RF Test
                                                                    Receiver



                                Test setup of radiated emissions up to 1GHz




                                                                     Antenna
                                                    1.0~4.0m         Tower


                                          3m                              Receiver
                            E
                                                                          Antenna
                            U
                            T




             1.5m

                    Ground Plane
                                                          □

                                                                    RF Test Spectrum
                                                                    Analyzer




                                Test setup of radiated emissions above 1GHz




                                                Page 19 of 22


                                                                            HeathCo LLC
                                                                            Intertek Report No:
                                                                            18121037HKG-004.doc




TEST REPORT
8.5    Occupied Bandwidth

Occupied Bandwidth Results:
Frequency (MHz)                   Occupied Bandwidth (kHz)

315MHz                                       178


The plot shows the fundamental emission when modulated. From the plot, the bandwidth is observed to
be 178kHz. The 99% Occupied bandwidth limit is 787.5kHz.




                                            Page 20 of 22


                                                                              HeathCo LLC
                                                                              Intertek Report No:
                                                                              18121037HKG-004.doc




TEST REPORT

9.0    CONFIDENTIALITY REQUEST

       For electronic filing, a preliminary copy of the confidentiality request is saved with filename:
       request.pdf.


10.0 EQUIPMENT LIST

1)     Radiated Emissions Test
Equipment                    EMI Test Receiver         Spectrum Analyzer         Biconical Antenna
Registration No.                 EW-3156                   EW-2253                   EW-0571
Manufacturer                       R&S                        R&S                      EMCO
Model No.                         ESR26                      FSP40                     3104C
Calibration Date            November 19, 2018          November 27, 2018         February 27, 2018
Calibration Due Date        November 19, 2019          November 27, 2019          August 27, 2019

Equipment                  Log Periodic Antenna        Double Ridged Guide     14m Double Shield RF
                                                            Antenna            Cable (20MHz to 6GHz)
Registration No.                  EW-0447                  EW-1015                    EW-2505
Manufacturer                        EMCO                     EMCO                      RADIALL
Model No.                            3148                     3115              nm / br5d / sma 14m
Calibration Date              January 17, 2018           May 17, 2019            October 27, 2018
Calibration Due Date            July 17, 2019          November 16, 2020         October 27, 2019

Equipment                      RF Cable 14m            Active Loop H-field
                             (1GHz to 26.5GHz)          (9kHz to 30MHz)

Registration No.                EW-2781                         EW-2313
Manufacturer                  GREATBILLION                   ELECTROMETRI
Model No.                    SMA m/SHF5MPU
                                                               EM-6876
                            /SMA m ra14m,26G
Calibration Date             October 27, 2018            March 08, 2018
Calibration Due Date         October 27, 2019          September 08, 2019




                                             Page 21 of 22


                                                                     HeathCo LLC
                                                                     Intertek Report No:
                                                                     18121037HKG-004.doc




TEST REPORT
2)     Bandedge Measurement
Equipment              RF Cable (up to 40GHz)    Spectrum Analyzer
                            1.5m length
Registration No.              EW-3104               EW-2253
Manufacturer                     N/A                  R&S
Model No.                SMA-M to SMA-M              FSP40
Calibration Date            July 03, 2018       November 27, 2018
Calibration Due Date        July 03, 2019       November 27, 2019


                                    END OF TEST REPORT




                                         Page 22 of 22