MPE Report

FCC ID: BEJE18MFF07

RF Exposure Info

Download: PDF
FCCID_3832884

MGUMI UNIVERSITY
         EMC CENTER                                                                                          Page 1 of 15



                                             MPE TEST REPORT

Applicant: LG Electronics USA.                                                Date of Issue: Apr. 27, 2018

1000 Sylvan Avenue,                                                          Order Number: GETEC—C1—18—182

Englewood Cliffs New Jersey United States 07632,                             Test Report Number: GETEC—E3—18—010

Attn: Kyung—Su Han / Director                                                Test Site: GUMI UNIVERSITY EMC CENTER
                                                                              (FCC Test Firm Registration No.: 269701)



                   FCC ID.            :       BEJE18MFFO7

                   Applicant :                LG Electronics USA.

         Rule Part(s)                 : FCC Part 1

         Test Procedure               : FCC Part 1, Subpart I, section 1.1310 and KDB 680106 D01 V02

         EUT Type                     : Refrigerator

         Type of Authority            : Certification

         Model Name                   : SKSCF3001P

         Trade Mark                   : LG



This equipment has been shown to be in compliance with the applicable technical standards as
indicated in the measurement report and was tested in accordance with the measurement procedures
specified in 47 CFR Part 1, Subpart I, section 1.1310 and KDB 680106 D01 V02

I attest to the accuracy of data. All measurements reported herein were performed by me or were
made under my supervision and are correct to the vest of my knowledge and belief. I assume full
responsibility for the completeness of these measurements and vouch for the qualifications of all
persons taking them.



Tested by,                                                                    Reviewed by,




              /24
   Sang Hyun Park, Associate Engineer                                           Hyoung Se&p/fiim(,’fechvnical\filanager
   GUMI UNIVERSITY EMC CENTER                                                   GUMI UNIVERSITY EMC CENTER



GETEC—QP—28—007 (Rev.02)                                                                                      EMC CENTER

This test report only contains the result ofa specific sample supplied for the examination.
It is not allowed to copy this report even partly without the approval of EMC center                          GUMIUNIVERSITY
                                                                                                                EMC CENTER


           Order Number                     : GETEC-C1-18-182                                                                                                      FCC Part 1
           Test Report Number               : GETEC-E3-18-010                                                                                               Page         2 / 15




                                                                          CONTENTS
1. GENERAL INFORMATION ...................................................................................................................................... 3
2. INTRODUCTION ........................................................................................................................................................ 4
3. PRODUCT INFORMATION ...................................................................................................................................... 5
   3.1 DESCRIPTION OF EUT .............................................................................................................................................. 5
   3.2 DEFINITION OF MODELS ........................................................................................................................................... 5
   3.3 SUPPORT EQUIPMENT / CABLES USED ..................................................................................................................... 5
   3.4 MODIFICATION ITEM(S) ........................................................................................................................................... 5
4. DESCRIPTION OF TESTS ......................................................................................................................................... 6
   4.1 TEST CONDITION ...................................................................................................................................................... 6
5. TEST EQUIPMENT USED ......................................................................................................................................... 6
6. TEST RESULT ............................................................................................................................................................. 7
   6.1 TEST SETUP .............................................................................................................................................................. 7
   6.2 MEASUREMENT PROCEDURE ................................................................................................................................... 7
   6.3 EQUIPMENT APPROVAL CONSIDERATIONS. ............................................................................................................. 8
   6.4 ENVIRONMENTAL EVALUATION AND EXPOSURE LIMIT............................................................................................ 9
   6.5 E AND H FIELD STRENGTH ..................................................................................................................................... 10
   6.5.1 FIELD STRENGTH MEASURE VALUE AT 10 CM FROM THE EDGES SURROUNDING THE EUT .............................. 10
7. PHOTOGRAPHS ....................................................................................................................................................... 11
   7.1 TEST PHOTOGRAPHS .............................................................................................................................................. 11




                                                                       EUT Type: Refrigerator
                                                                      FCC ID.: BEJE18MFF07                                                    G E T E C


         Order Number          : GETEC-C1-18-182                                                           FCC Part 1
         Test Report Number    : GETEC-E3-18-010                                                    Page       3 / 15




Scope: Measurement and determination of electromagnetic emissions (EME) of radio frequency devices
including intentional and / or unintentional radiators for compliance with technical rules and regulations of
the Federal Communications Commission.

1. General Information

Applicant: LG Electronics USA.

Applicant Address: 1000 Sylvan Avenue,
                        Englewood Cliffs New Jersey United States 07632
Manufacturer: LG Electronics Inc.

Manufacturer Address: 170, Sungsanpaechong-ro, Seongsan-gu, Changwon-si,

Gyeongsangnam-do, 642-711, Korea

Contact Person: Bogeun Lee / Research Engineer

Tel. Number: +82-55-260-3966



          FCC ID.                   BEJE18MFF07

          EUT Type                  Refrigerator

          Model Name                SKSCF3001P

          Rule Part(s)              FCC Part 1

          Type of Authority         Certification

          Test Procedure(s)         FCC Part 1, Subpart I, section 1.1310 and KDB 680106 D01 V02

          Dates of Test             Apr. 11, 2018

          Place of Test             GUMI UNIVERSITY EMC CENTER
                                     (FCC Test Firm Registration Number: 269701)
                                     37 Yaeun-ro, Gumi-si, Gyeongsangbuk-do, 730-711, Republic of Korea.

          Test Report Number        GETEC-E3-18-010

          Dates of Issue            Apr. 27, 2018




                                                  EUT Type: Refrigerator
                                                FCC ID.: BEJE18MFF07                        G E T E C


      Order Number          : GETEC-C1-18-182                                                                FCC Part 1
      Test Report Number    : GETEC-E3-18-010                                                         Page       4 / 15



2. Introduction

 The measurement procedure described in American National Standard for Methods of Measurement of Radio-Nose
 Emissions From Low-Voltage Electrical and Electronic Equipment in the Range of 9 kHz to 40 GHz (ANSI C63.4-
 2014) was used in determining radiated and conducted emissions emanating from LG Electronics USA.
 Refrigerator (Model name: SKSCF3001P)

 These measurement tests were conducted at GUMI UNIVERSITY EMC CENTER.
 The site address is 37 Yaeun-ro, Gumi-si, Gyeongsangbuk-do, 730-711, Gyeongnam 641-713, Korea
 This test site is one of the highest point of GUMI UNIVERSITY at about 200 kilometers away from Seoul city and
 40 kilometers away from Daegu city. It is located in the valley surrounded by mountains in all directions where
 ambient radio signal conditions are quiet and a favorable area to measure the radio frequency interference on open
 field test site for the computing and ISM devices manufactures. The detailed description of the measurement facility
 was found to be in compliance with the requirements of §2.948 according to ANSI C63.4 (2014)




                                                                                 GUMI UNIVERSITY EMC CENTER
                                                                                 37 Yaeun-ro, Gumi-si,
                                                                                 Gyeongsangbuk-do, 730-711,
                                                                                 Gyeongnam 641-713, Korea
                                                                                 Tel: +82-54-440-1195
                                                                                 Fax: +82-54-440-1199




      Fig 1. The map above shows the GUMI UNIVERSITY in vicinity area.




                                              EUT Type: Refrigerator
                                             FCC ID.: BEJE18MFF07                            G E T E C


          Order Number             : GETEC-C1-18-182                                                               FCC Part 1
          Test Report Number       : GETEC-E3-18-010                                                        Page       5 / 15



3. Product Information

3.1 Description of EUT

The Equipment under Test (EUT) is the LG Electronics USA. Refrigerator (Model Name: SKSCF3001P)
FCC ID.: BEJE18MFF07.


 Type of Equipment                    Refrigerator
 Model Name                           SKSCF3001P
 Serial Number                        Prototype
 RF Frequency                         330 kHz ~ 370 kHz
 External connector                   DC input 1 EA
 Rated Voltage                        Input : AC 115 V, 60 Hz ( Wireless Power Transmitter input voltage: DC 12 V)
 Output Electricity Power             Less than 3 W
 Size(W x H x T)                      35 3/4(W) x23 7/8(D) x831/2(H) inch
                                      (Wireless Power Transmitter module :50 (mm) x 35 (mm) x 1.0 (mm))

3.2 Definition of models

- None.

3.3 Support Equipment / Cables used

3.3.1 Used Support Equipment
 Description                   Manufacturer                    Model Name            S/N & FCC ID.

                                                                                     S/N: -
 None                          -                               -
                                                                                     FCC ID.: -
See “Appendix E – Test Setup Photographs” for actual system test set-up


3.3.2 System configuration
 Description             Manufacturer                              Model Name                     S/N & FCC ID.

                                                                                                  S/N: -.
 None.                   -                                         -
                                                                                                  FCC ID.: -.


3.3.3 Used Cable(s)

 Cable Name              Condition                                                                Description

 Power cable             Connected to the EUT and AC power                                        2.20 m Unshielded.



3.4 Modification Item(s)

 -. None

                                                    EUT Type: Refrigerator
                                                   FCC ID.: BEJE18MFF07                            G E T E C


       Order Number           : GETEC-C1-18-182                                                                FCC Part 1
       Test Report Number     : GETEC-E3-18-010                                                         Page       6 / 15




4. Description of tests

4.1 Test Condition
The EUT was installed, arranged and operated in a manner that is most representative of equipment as typically used.
The measurements were carried out while varying operating modes and cable positions within typically arrangement to
determine maximum emission level.
The representative and worst test mode(s) were noted in the test report.

    Test Voltage / Frequency: AC 115V, 60 Hz
     ( Wireless Power Transfer Device were supplied DC 12 V from main system)


    Operating condition during the test(s) :
       This device has been tested in the configurations of charging mode
             Charging Current                         Support Equipment                       Comment
                   1 000 mA                       Refrigerator Shelf RX module



5. Test Equipment used
     Model Name Manufacturer                                 Description          Serial Number    Due to Calibration
 - ELT-400          Narda Safety Test Solutions GmbH        EMF Tester           J-0005           Sep. 09, 2018
 - HI-6105          ETS LINDGREN                            Electric field Probe 203871           Dec. 21, 2018
All test equipment used is calibrated on a regular basis.




                                                EUT Type: Refrigerator
                                                FCC ID.: BEJE18MFF07                           G E T E C


       Order Number          : GETEC-C1-18-182                                                                 FCC Part 1
       Test Report Number    : GETEC-E3-18-010                                                          Page       7 / 15



6. Test Result

6.1 Test Setup


                                   Side
                                    Side11

                         Side
                          Side55                          Side
                                                           Side44




 Side
 Side22




                                   Side
                                    Side66

                        Side
                         Side33



6.2 Measurement Procedure


The RF exposure test was performed on 360 degree turn table in anechoic chamber. The measurement probe was placed
at test distance ( 10 ㎝) which is between the edge of the charger and the geometric center of probe. The turn table was
rotated 360 degree to search of highest strength. The highest emission level was recorded and compared with limit as
soon as measurement of each points (Side 1 ~ 6) were completed. The EUT were measured according to the dictates of
KDB 680106 D01v02.




                                               EUT Type: Refrigerator
                                              FCC ID.: BEJE18MFF07                             G E T E C


       Order Number         : GETEC-C1-18-182                                                         FCC Part 1
       Test Report Number   : GETEC-E3-18-010                                                  Page       8 / 15




6.3 Equipment Approval Considerations.
    The EUT does with item 5.2 of KDB 680106 D01v02
    a) Power transfer frequency is less that 1 ㎒
        - Power transfer(Main Carrier) frequency is fixed between 330 kHz ~ 370 kHz

   b) Output power from each primary coil is less than 5 watts.
      - The maximum field strength of fundamental : 66.18 dBµV/m at 3 m. The EIRP calculation is reference to
      KDB 789033
       ※ EIRP[dBm] = E[dBµV/m]+20log(d[meters]) - 104.77 , d = 3 m
       ※ 66.18 dBµV/m – 95.2 = -29.02 dBm EIRP
       ※ The output power from primary coil is 0.001 253 ㎽

   c) The transfer system includes only single primary and secondary coils. This includes charging
       systems that may have multiple primary coils and clients that are able to detect and allow
       coupling only between individual pairs of coils
       - The system is consists of single primary and secondary coils.




   d) Client device is inserted in or placed directly in contact with the transmitter
      - Client device(Receiver) is placed by the transmitter with a less than 10 mm gap.
        Refer to following photo.




   e) The maximum coupling surface area of the transmit(charging) device is between 60 cm2 and 400
      cm2
      - The shape of primary and secondary coils are same and the they are center-aligned.
      Maximum coupling surface area of transmitter is under 20 cm2

   f) Aggregate leakage fields at 10 cm surrounding the device from all simultaneous transmitting
      coils are demonstrated to be less than 30% of the MPE limit.
       - 0.478 A/m (maximum measure value) < 0.489 A/m (30% MPE limit)




                                             EUT Type: Refrigerator
                                             FCC ID.: BEJE18MFF07                      G E T E C


        Order Number          : GETEC-C1-18-182                                                                 FCC Part 1
        Test Report Number    : GETEC-E3-18-010                                                          Page       9 / 15




 6.4 Environmental evaluation and exposure limit
 * according to FCC CFR 47 part 1, 1.1307(b), 1.1310
 §1.1310 : The criteria listed in the following table shall be used to evaluate the environment impact of human exposure
 to radio frequency (RF) radiation as specified in §1.1307(b), except in the case of portable devices which shall be
 evaluated according to the provisions of FCC part 2.1093 of this chapter


                 Table 1 – LIMITS FOR MAXIMUM PERMISSIBLE EXPOSURE (MPE)
    Frequency             Electric Field          Magnetic Field            Power Density          Average Time
                                                                                         2
      Range               Strength(V/m)           Strength(A/m)              (mW/cm )                (minutes)
      (MHz)
                               (A) Limits for Occupational /Control Exposures
     0.3 – 3.0                  614                     1.63                   *(100)                     6
     3.0 – 30                 1842/f                   4.89/f                 *(900/f2)                   6
     30 – 300                   61.4                   6.163                     1.0                      6
   300 – 1 500                                                                  f/300                     6
 1 500 – 100 000                                                                  5                       6
                          (B) Limits for General Population / Uncontrol Exposures
    0.3 – 1.34                  614                     1.63                   *(100)                    30
                                                                                        2
    1.34 – 30                  824/f                    2.19                  *(180/f )                  30
     30 – 300                   27.5                   0.073                     0.2                     30
   300 – 1 500                                                                 f/1 500                   30
 1 500 – 100 000                                                                 1.0                     30
F=frequency in MHz
* = Plane wave equivalent power density


Note 1 to Table 1: Occupational/controlled limits apply in situations in which persons are exposed as a
consequence of their employment provided those persons are fully aware of the potential for exposure
and can exercise control over their exposure. Limits for occupational/controlled exposure also apply in
situations when an individual is transient through a location where occupational/controlled limits apply
provided he or she is made aware of the potential for exposure.


Note 2 to Table 1: General population/uncontrolled exposures apply in situations in which the general
public may be exposed, or in which persons that are exposed as a consequence of their employment may
not be fully aware of the potential for exposure or can not exercise control over their exposure.


                                                EUT Type: Refrigerator
                                                FCC ID.: BEJE18MFF07                            G E T E C


        Order Number         : GETEC-C1-18-182                                                  FCC Part 1
        Test Report Number   : GETEC-E3-18-010                                           Page      10 / 15




6.5 E and H field strength


Temperature                  :     22.5 ℃
Relative Humidity            :     40.5 % R.H.
Air pressure                 :     101.0 kPa
Test mode : Continuous Power transmitting mode

6.5.1 Field Strength measure value at 10 cm from the edges surrounding the EUT
Electric Field Strength

    Test Position         Probe Measure Result(V/m)          Limit(V/m)          30 % Limit(V/m)

        Side 1                      12.22                       614                   184.2

        Side 2                      13.85                       614                   184.2

        Side 3                      12.90                       614                   184.2

        Side 4                      12.20                       614                   184.2

        Side 5                      5.34                        614                   184.2



Magnetic Field Strength

    Test Position         Probe Measure Result(A/m)          Limit(A/m)          30 % Limit(A/m)

        Side 1                      0.114                       1.63                  0.489

        Side 2                      0.109                       1.63                  0.489

        Side 3                      0.134                       1.63                  0.489

        Side 4                      0.105                       1.63                  0.489

        Side 5                      0.141                       1.63                  0.489




                                             EUT Type: Refrigerator
                                             FCC ID.: BEJE18MFF07                G E T E C


         Order Number         : GETEC-C1-18-182                                  FCC Part 1
         Test Report Number   : GETEC-E3-18-010                           Page      11 / 15




7. Photographs

7.1 Test Photographs
Test model No.: SKSCF3001P
Test with full load
Side 1
< Electric field >




< Magnetic field >




                                              EUT Type: Refrigerator
                                              FCC ID.: BEJE18MFF07     G E T E C


         Order Number         : GETEC-C1-18-182                                  FCC Part 1
         Test Report Number   : GETEC-E3-18-010                           Page      12 / 15




Side 2
< Electric field >




< Magnetic field >




                                              EUT Type: Refrigerator
                                              FCC ID.: BEJE18MFF07     G E T E C


         Order Number         : GETEC-C1-18-182                                  FCC Part 1
         Test Report Number   : GETEC-E3-18-010                           Page      13 / 15




Side 3
< Electric field >




< Magnetic field >




                                              EUT Type: Refrigerator
                                              FCC ID.: BEJE18MFF07     G E T E C


         Order Number         : GETEC-C1-18-182                                  FCC Part 1
         Test Report Number   : GETEC-E3-18-010                           Page      14 / 15




Side 4
< Electric field >




< Magnetic field >




                                              EUT Type: Refrigerator
                                              FCC ID.: BEJE18MFF07     G E T E C


         Order Number         : GETEC-C1-18-182                                  FCC Part 1
         Test Report Number   : GETEC-E3-18-010                           Page      15 / 15




Side 5
< Electric field >




< Magnetic field >




                                                                            - The end -



                                              EUT Type: Refrigerator
                                              FCC ID.: BEJE18MFF07     G E T E C



Document Created: 2018-04-27 18:58:19
Document Modified: 2018-04-27 18:58:19

© 2024 FCC.report