Test Report_Part II

FCC ID: BEJA408SW19

Test Report

Download: PDF
FCCID_4498356

Order Number         : GETEC-C1-19-411                           FCC Part 18
Test Report Number   : GETEC-E3-19-022                           Page 1 / 16




                                     APPENDIX B
                          : OPTIONAL MEASURE TEST




                              EUT Type: Household Refrigerator
                                   FCC ID.: BEJA408SW19


   Order Number         : GETEC-C1-19-411                           FCC Part 18
   Test Report Number   : GETEC-E3-19-022                           Page 2 / 16



Test model No.: URETC1408N
Test with full load
                                                 Side 1
                                            < Electric field >




                                            < Magnetic field >




                                 EUT Type: Household Refrigerator
                                      FCC ID.: BEJA408SW19


Order Number         : GETEC-C1-19-411                           FCC Part 18
Test Report Number   : GETEC-E3-19-022                           Page 3 / 16




                                              Side 2
                                         < Electric field >




                                         < Magnetic field >




                              EUT Type: Household Refrigerator
                                   FCC ID.: BEJA408SW19


Order Number         : GETEC-C1-19-411                           FCC Part 18
Test Report Number   : GETEC-E3-19-022                           Page 4 / 16




                                              Side 3
                                         < Electric field >




                                         < Magnetic field >




                              EUT Type: Household Refrigerator
                                   FCC ID.: BEJA408SW19


Order Number         : GETEC-C1-19-411                           FCC Part 18
Test Report Number   : GETEC-E3-19-022                           Page 5 / 16




                                              Side 4
                                         < Electric field >




                                         < Magnetic field >




                              EUT Type: Household Refrigerator
                                   FCC ID.: BEJA408SW19


Order Number         : GETEC-C1-19-411                           FCC Part 18
Test Report Number   : GETEC-E3-19-022                           Page 6 / 16




                                              Side 5
                                         < Electric field >




                                         < Magnetic field >




                              EUT Type: Household Refrigerator
                                   FCC ID.: BEJA408SW19


    Order Number            : GETEC-C1-19-411                                       FCC Part 18
    Test Report Number      : GETEC-E3-19-022                                        Page 7 / 16



Test result
Distance 1 cm
Electric Field Strength

    Test Position         Probe Measure Result(V/m)         Limit(V/m)   50 % Limit(V/m)

       Side 1                       9.42                           -            -

       Side 2                       8.68                           -            -

       Side 3                       8.95                           -            -

       Side 4                       6.87                           -            -

       Side 5                       7.85                           -            -


Magnetic Field Strength

    Test Position         Probe Measure Result(A/m)         Limit(A/m)   50 % Limit(A/m)

       Side 1                       0.184                          -            -

       Side 2                       0.135                          -            -

       Side 3                       0.145                          -            -

       Side 4                       0.204                          -            -

       Side 5                       1.874                          -            -




                                      EUT Type: Household Refrigerator
                                            FCC ID.: BEJA408SW19


    Order Number            : GETEC-C1-19-411                                       FCC Part 18
    Test Report Number      : GETEC-E3-19-022                                        Page 8 / 16




Distance 2 cm
Electric Field Strength

    Test Position         Probe Measure Result(V/m)         Limit(V/m)   50 % Limit(V/m)

       Side 1                       8.48                           -            -

       Side 2                       8.34                           -            -

       Side 3                       8.76                           -            -

       Side 4                       6.43                           -            -

       Side 5                       6.93                           -            -


Magnetic Field Strength

    Test Position         Probe Measure Result(A/m)         Limit(A/m)   50 % Limit(A/m)

       Side 1                       0.182                          -            -

       Side 2                       0.137                          -            -

       Side 3                       0.141                          -            -

       Side 4                       0.198                          -            -

       Side 5                       1.613                          -            -




                                      EUT Type: Household Refrigerator
                                            FCC ID.: BEJA408SW19


    Order Number            : GETEC-C1-19-411                                       FCC Part 18
    Test Report Number      : GETEC-E3-19-022                                        Page 9 / 16




Distance 3 cm
Electric Field Strength

    Test Position         Probe Measure Result(V/m)         Limit(V/m)   50 % Limit(V/m)

       Side 1                       9.49                           -            -

       Side 2                       8.35                           -            -

       Side 3                       8.89                           -            -

       Side 4                       6.07                           -            -

       Side 5                       6.59                           -            -


Magnetic Field Strength

    Test Position         Probe Measure Result(A/m)         Limit(A/m)   50 % Limit(A/m)

       Side 1                       0.186                          -            -

       Side 2                       0.131                          -            -

       Side 3                       0.148                          -            -

       Side 4                       0.199                          -            -

       Side 5                       1.338                          -            -




                                      EUT Type: Household Refrigerator
                                            FCC ID.: BEJA408SW19


    Order Number            : GETEC-C1-19-411                                       FCC Part 18
    Test Report Number      : GETEC-E3-19-022                                       Page 10 / 16




Distance 4 cm
Electric Field Strength

    Test Position         Probe Measure Result(V/m)         Limit(V/m)   50 % Limit(V/m)

       Side 1                       8.26                           -            -

       Side 2                       7.88                           -            -

       Side 3                       8.63                           -            -

       Side 4                       5.69                           -            -

       Side 5                       5.69                           -            -


Magnetic Field Strength

    Test Position         Probe Measure Result(A/m)         Limit(A/m)   50 % Limit(A/m)

       Side 1                       0.182                          -            -

       Side 2                       0.130                          -            -

       Side 3                       0.146                          -            -

       Side 4                       0.200                          -            -

       Side 5                       1.171                          -            -




                                      EUT Type: Household Refrigerator
                                            FCC ID.: BEJA408SW19


    Order Number            : GETEC-C1-19-411                                       FCC Part 18
    Test Report Number      : GETEC-E3-19-022                                       Page 11 / 16




Distance 5 cm
Electric Field Strength

    Test Position         Probe Measure Result(V/m)         Limit(V/m)   50 % Limit(V/m)

       Side 1                       7.86                           -            -

       Side 2                       7.21                           -            -

       Side 3                       8.29                           -            -

       Side 4                       4.87                           -            -

       Side 5                       5.13                           -            -


Magnetic Field Strength

    Test Position         Probe Measure Result(A/m)         Limit(A/m)   50 % Limit(A/m)

       Side 1                       0.178                          -            -

       Side 2                       0.133                          -            -

       Side 3                       0.141                          -            -

       Side 4                       0.205                          -            -

       Side 5                       1.086                          -            -




                                      EUT Type: Household Refrigerator
                                            FCC ID.: BEJA408SW19


    Order Number            : GETEC-C1-19-411                                       FCC Part 18
    Test Report Number      : GETEC-E3-19-022                                       Page 12 / 16




Distance 6 cm
Electric Field Strength

    Test Position         Probe Measure Result(V/m)         Limit(V/m)   50 % Limit(V/m)

       Side 1                       8.12                           -            -

       Side 2                       6.42                           -            -

       Side 3                       7.52                           -            -

       Side 4                       4.44                           -            -

       Side 5                       5.65                           -            -


Magnetic Field Strength

    Test Position         Probe Measure Result(A/m)         Limit(A/m)   50 % Limit(A/m)

       Side 1                       0.170                          -            -

       Side 2                       0.131                          -            -

       Side 3                       0.149                          -            -

       Side 4                       0.213                          -            -

       Side 5                       0.993                          -            -




                                      EUT Type: Household Refrigerator
                                            FCC ID.: BEJA408SW19


    Order Number            : GETEC-C1-19-411                                       FCC Part 18
    Test Report Number      : GETEC-E3-19-022                                       Page 13 / 16




Distance 7 cm
Electric Field Strength

    Test Position         Probe Measure Result(V/m)         Limit(V/m)   50 % Limit(V/m)

       Side 1                       8.04                           -            -

       Side 2                       5.41                           -            -

       Side 3                       7.29                           -            -

       Side 4                       4.17                           -            -

       Side 5                       4.77                           -            -


Magnetic Field Strength

    Test Position         Probe Measure Result(A/m)         Limit(A/m)   50 % Limit(A/m)

       Side 1                       0.185                          -            -

       Side 2                       0.131                          -            -

       Side 3                       0.154                          -            -

       Side 4                       0.211                          -            -

       Side 5                       0.930                          -            -




                                      EUT Type: Household Refrigerator
                                            FCC ID.: BEJA408SW19


    Order Number            : GETEC-C1-19-411                                       FCC Part 18
    Test Report Number      : GETEC-E3-19-022                                       Page 14 / 16




Distance 8 cm
Electric Field Strength

    Test Position         Probe Measure Result(V/m)         Limit(V/m)   50 % Limit(V/m)

       Side 1                       7.90                           -            -

       Side 2                       5.63                           -            -

       Side 3                       6.55                           -            -

       Side 4                       3.84                           -            -

       Side 5                       4.65                           -            -


Magnetic Field Strength

    Test Position         Probe Measure Result(A/m)         Limit(A/m)   50 % Limit(A/m)

       Side 1                       0.174                          -            -

       Side 2                      0.1327                          -            -

       Side 3                       0.143                          -            -

       Side 4                       0.194                          -            -

       Side 5                       0.841                          -            -




                                      EUT Type: Household Refrigerator
                                            FCC ID.: BEJA408SW19


    Order Number            : GETEC-C1-19-411                                       FCC Part 18
    Test Report Number      : GETEC-E3-19-022                                       Page 15 / 16




Distance 9 cm
Electric Field Strength

    Test Position         Probe Measure Result(V/m)         Limit(V/m)   50 % Limit(V/m)

       Side 1                       8.82                           -            -

       Side 2                       5.61                           -            -

       Side 3                       6.55                           -            -

       Side 4                       3.61                           -            -

       Side 5                       6.04                           -            -


Magnetic Field Strength

    Test Position         Probe Measure Result(A/m)         Limit(A/m)   50 % Limit(A/m)

       Side 1                       0.179                          -            -

       Side 2                       0.134                          -            -

       Side 3                       0.156                          -            -

       Side 4                       0.198                          -            -

       Side 5                       0.839                          -            -




                                      EUT Type: Household Refrigerator
                                            FCC ID.: BEJA408SW19


    Order Number            : GETEC-C1-19-411                                       FCC Part 18
    Test Report Number      : GETEC-E3-19-022                                       Page 16 / 16




Distance 10 cm
Electric Field Strength

    Test Position         Probe Measure Result(V/m)         Limit(V/m)   50 % Limit(V/m)

       Side 1                       8.25                           -            -

       Side 2                       4.83                           -            -

       Side 3                       6.38                           -            -

       Side 4                       3.90                           -            -

       Side 5                       5.77                           -            -


Magnetic Field Strength

    Test Position         Probe Measure Result(A/m)         Limit(A/m)   50 % Limit(A/m)

       Side 1                       0.180                          -            -

       Side 2                       0.131                          -            -

       Side 3                       0.145                          -            -

       Side 4                       0.192                          -            -

       Side 5                       0.736                          -            -




                                      EUT Type: Household Refrigerator
                                            FCC ID.: BEJA408SW19



Document Created: 2019-10-31 19:22:49
Document Modified: 2019-10-31 19:22:49

© 2024 FCC.report