SAR attachment 1

FCC ID: BCGA1213

RF Exposure Info

Download: PDF
FCCID_838930

                                                                                     Date/Time: 7/30/2007 6:43:37 PM

Test Laboratory: Compliance Certification Services

System Performance Check @ 2450 MHz
DUT: Dipole 2450 MHz; Type: D2450V2;Serial: D2450V2 - SN:706

Communication System: CW - 2450 MHz;Frequency: 2450 MHz;Duty Cycle: 1:1
Medium parameters used: f = 2450 MHz; σ = 2.02 mho/m; εr = 54.4; ρ = 1000 kg/m3
Phantom section: Flat Section

Room AmbientTemperature: 22.0deg. C; Liquid Temperature: 21.0 deg. C

DASY4 Configuration:
- Area Scan setting - Find Secondary Maximum Within: 2.0 dB and witha peak SAR value greater than 0.0012W/kg
- Probe: EX3DV4 - SN3554; ConvF(6.14, 6.14, 6.14); Calibrated: 4/24/2007
- Sensor-Surface: 4mm (Mechanical Surface Detection)
- Electronics: DAE3 Sn427; Calibrated: 11/16/2006
- Phantom: Flat Phantom ELI4.0; Type: QDOVA001BA; Serial: SN:1003
- Measurement SW: DASY4, V4.7 Build 53; Postprocessing SW: SEMCAD, V1.8 Build 172

d=10mm, Pin=250mW/Area Scan (7x7x1): Measurement grid: dx=15mm, dy=15mm
Maximum value of SAR (measured) = 15.2 mW/g

d=10mm, Pin=250mW/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=7.5mm, dy=7.5mm, dz=5mm
Reference Value = 86.9 V/m; Power Drift = 0.042 dB
Peak SAR (extrapolated) = 27.1 W/kg
SAR(1 g) = 13.4 mW/g; SAR(10 g) = 6.26 mW/g
Maximum value of SAR (measured) = 15.0 mW/g




                     0 dB = 15.0mW/g


                                                                           Date/Time: 7/30/2007 6:54:30 PM

Test Laboratory: Compliance Certification Services

System Performance Check @ 2450 MHz
DUT: Dipole 2450 MHz; Type: D2450V2; Serial: D2450V2 - SN:706

Communication System: CW - 2450 MHz; Frequency: 2450 MHz;Duty Cycle: 1:1



d=10mm, Pin=250mW/Z Scan (1x1x41): Measurement grid: dx=20mm, dy=20mm, dz=2.5mm
Maximum value of SAR (measured) = 16.0 mW/g


                                                                                     Date/Time: 7/31/2007 6:09:23 PM

Test Laboratory: Compliance Certification Services

System Performance Check @ 2450 MHz
DUT: Dipole 2450 MHz; Type: D2450V2;Serial: D2450V2 - SN:706

Communication System: CW - 2450 MHz;Frequency: 2450 MHz;Duty Cycle: 1:1
Medium parameters used: f = 2450 MHz; σ = 2.02 mho/m; εr = 54.4; ρ = 1000 kg/m3
Phantom section: Flat Section

Room AmbientTemperature: 22.0deg. C; Liquid Temperature: 21.0 deg. C

DASY4 Configuration:
- Area Scan setting - Find Secondary Maximum Within: 2.0 dB and witha peak SAR value greater than 0.0012W/kg
- Probe: EX3DV4 - SN3554; ConvF(6.14, 6.14, 6.14); Calibrated: 4/24/2007
- Sensor-Surface: 4mm (Mechanical Surface Detection)
- Electronics: DAE3 Sn427; Calibrated: 11/16/2006
- Phantom: Flat Phantom ELI4.0; Type: QDOVA001BA; Serial: SN:1003
- Measurement SW: DASY4, V4.7 Build 53; Postprocessing SW: SEMCAD, V1.8 Build 172

d=10mm, Pin=250mW/Area Scan (7x7x1): Measurement grid: dx=15mm, dy=15mm
Maximum value of SAR (measured) = 15.1 mW/g

d=10mm, Pin=250mW/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=7.5mm, dy=7.5mm, dz=5mm
Reference Value = 86.8 V/m; Power Drift = -0.050 dB
Peak SAR (extrapolated) = 27.2 W/kg
SAR(1 g) = 13.6 mW/g; SAR(10 g) = 6.33 mW/g
Maximum value of SAR (measured) = 15.5 mW/g




                     0 dB = 15.5mW/g


                                                                           Date/Time: 7/31/2007 6:20:13 PM

Test Laboratory: Compliance Certification Services

System Performance Check @ 2450 MHz
DUT: Dipole 2450 MHz; Type: D2450V2; Serial: D2450V2 - SN:706

Communication System: CW - 2450 MHz; Frequency: 2450 MHz;Duty Cycle: 1:1



d=10mm, Pin=250mW/Z Scan (1x1x41): Measurement grid: dx=20mm, dy=20mm, dz=2.5mm
Maximum value of SAR (measured) = 16.7 mW/g



Document Created: 2007-07-31 18:55:50