11697707-S4V1 HAC_RF_App B System Validation Plots

FCC ID: BCG-E3174A

Test Report

Download: PDF
FCCID_3533336

Test Laboratory: UL Verification Services Inc. SAR Lab C                           Date: 5/30/2017

HAC-RF Emission
Communication System: UID 0, CW; Frequency: 835 MHz; Duty Cycle: 1:1
Phantom section: RF Section
DASY5 Configuration:
- Probe: ER3DV6 - SN2540; ConvF(1, 1, 1); Calibrated: 8/10/2015;
- Sensor-Surface: (Fix Surface)
- Electronics: DAE4 Sn1377; Calibrated: 9/14/2016
- Phantom: HAC Test Arch with AMCC; Type: SD HAC P01 BB
- Measurement SW: DASY52, Version 52.8 (7);SEMCAD X Version 14.6.10 (7164)


Dipole E-Field measurement 835MHz/835 MHz/Hearing Aid Compatibility Test at 15mm
distance (41x361x1): Interpolated grid: dx=0.5000 mm, dy=0.5000 mm
Device Reference Point: 0, 0, -6.3 mm
Reference Value = 105.6 V/m; Power Drift = 0.03 dB
PMR not calibrated. PMF = 1.000 is applied.
E-field emissions = 112.5 V/m
Near-field category: M4     (AWF 0 dB)

                                             PMF scaled E-field
                                             Grid 1 M4 Grid 2 M4 Grid 3 M4
                                             98.96 V/m     101.8 V/m   101.3 V/m
                                             Grid 4 M4     Grid 5 M4   Grid 6 M4
                                             61.46 V/m     62.65 V/m   61.96 V/m
                                             Grid 7 M4     Grid 8 M4   Grid 9 M4
                                             109.7 V/m     112.5 V/m   110.9 V/m




                        0 dB = 112.5 V/m = 41.02 dBV/m



                                                                                                     Plot No. 1


Test Laboratory: UL Verification Services Inc. SAR Lab C                           Date: 5/30/2017

HAC-RF Emission
Communication System: UID 0, CW; Frequency: 1880 MHz; Duty Cycle: 1:1
Phantom section: RF Section
DASY5 Configuration:
- Probe: ER3DV6 - SN2540; ConvF(1, 1, 1); Calibrated: 8/10/2015;
- Sensor-Surface: (Fix Surface)
- Electronics: DAE4 Sn1377; Calibrated: 9/14/2016
- Phantom: HAC Test Arch with AMCC; Type: SD HAC P01 BB
- Measurement SW: DASY52, Version 52.8 (7);SEMCAD X Version 14.6.10 (7164)

Dipole E-Field Measurement 1880MHz/1880 MHz/Hearing Aid Compatibility Test at
15mm distance (41x181x1): Interpolated grid: dx=0.5000 mm, dy=0.5000 mm
Device Reference Point: 0, 0, -6.3 mm
Reference Value = 164.4 V/m; Power Drift = -0.00 dB
PMR not calibrated. PMF = 1.000 is applied.
E-field emissions = 90.84 V/m
Near-field category: M3 (AWF 0 dB)

                                         PMF scaled E-field
                                          Grid 1 M3 Grid 2 M3 Grid 3 M3
                                          82.42 V/m        85.15 V/m   84.75 V/m
                                          Grid 4 M3        Grid 5 M3   Grid 6 M3
                                          70.12 V/m        71.50 V/m   70.87 V/m
                                          Grid 7 M3        Grid 8 M3   Grid 9 M3
                                          87.99 V/m        90.84 V/m   90.27 V/m




                      0 dB = 90.84 V/m = 39.17 dBV/m


                                                                                                     Plot No. 2


Test Laboratory: UL Verification Services Inc. SAR Lab C                           Date: 5/30/2017

HAC-RF Emission
Communication System: UID 0, CW (0); Frequency: 2450 MHz; Duty Cycle: 1:1
Phantom section: RF Section
DASY5 Configuration:
- Probe: ER3DV6 - SN2540; ConvF(1, 1, 1); Calibrated: 8/10/2015;
- Sensor-Surface: (Fix Surface)
- Electronics: DAE4 Sn1377; Calibrated: 9/14/2016
- Phantom: HAC Test Arch with AMCC; Type: SD HAC P01 BB
- Measurement SW: DASY52, Version 52.8 (7);SEMCAD X Version 14.6.10 (7164)

Dipole E-Field Measurement 2450MHz/2450 MHz/Hearing Aid Compatibility Test at
15mm distance (41x181x1): Interpolated grid: dx=0.5000 mm, dy=0.5000 mm
Device Reference Point: 0, 0, -6.3 mm
Reference Value = 96.68 V/m; Power Drift = 0.05 dB
PMR not calibrated. PMF = 1.000 is applied.
E-field emissions = 87.30 V/m
Near-field category: M3 (AWF 0 dB)

                                         PMF scaled E-field
                                          Grid 1 M3 Grid 2 M3 Grid 3 M3
                                          84.85 V/m        86.96 V/m   86.31 V/m
                                          Grid 4 M3        Grid 5 M3   Grid 6 M3
                                          82.26 V/m        83.81 V/m   82.84 V/m
                                          Grid 7 M3        Grid 8 M3   Grid 9 M3
                                          84.41 V/m        87.30 V/m   86.83 V/m




                      0 dB = 87.30 V/m = 38.82 dBV/m


                                                                                                     Plot No. 3


Test Laboratory: UL Verification Services Inc. SAR Lab C                       Date: 6/13/2017

HAC-RF Emission
Communication System: UID 0, CW (0); Frequency: 5500 MHz; Duty Cycle: 1:1
Phantom section: RF Section
DASY5 Configuration:
- Probe: EF3DV3 - SN4041 (5-6 GHz); ConvF(1, 1, 1); Calibrated: 3/14/2017;
- Sensor-Surface: (Fix Surface)
- Electronics: DAE4 Sn1377; Calibrated: 9/14/2016
- Phantom: HAC Test Arch with AMCC; Type: SD HAC P01 BB
- Measurement SW: DASY52, Version 52.8 (7);SEMCAD X Version 14.6.10 (7164)

Dipole E-Field Measurement 5.5GHz/5.5GHz/Hearing Aid Compatibility Test at 15mm
distance (41x181x1): Interpolated grid: dx=0.5000 mm, dy=0.5000 mm
Device Reference Point: 0, 0, -6.3 mm
Reference Value = 25.18 V/m; Power Drift = 0.00 dB
PMR not calibrated. PMF = 1.000 is applied.
E-field emissions = 98.22 V/m
Near-field category: M3 (AWF 0 dB)

                                         PMF scaled E-field
                                         Grid 1 M3 Grid 2 M3 Grid 3 M3
                                         80.54 V/m     81.58 V/m   78.23 V/m
                                         Grid 4 M3     Grid 5 M3   Grid 6 M3
                                         96.90 V/m     98.22 V/m   94.48 V/m
                                         Grid 7 M3     Grid 8 M3   Grid 9 M3
                                         78.94 V/m     79.93 V/m   76.89 V/m




                      0 dB = 98.22 V/m = 39.84 dBV/m
                                                                                                 Plot No. 4


Test Laboratory: UL Verification Services Inc. SAR Lab C                           Date: 6/13/2017

HAC-RF Emission
Communication System: UID 0, CW (0); Frequency: 5600 MHz; Duty Cycle: 1:1
Phantom section: RF Section
DASY5 Configuration:
- Probe: EF3DV3 - SN4041 (5-6 GHz); ConvF(1, 1, 1); Calibrated: 3/14/2017;
- Sensor-Surface: (Fix Surface)
- Electronics: DAE4 Sn1377; Calibrated: 9/14/2016
- Phantom: HAC Test Arch with AMCC; Type: SD HAC P01 BB
- Measurement SW: DASY52, Version 52.8 (7);SEMCAD X Version 14.6.10 (7164)

Dipole E-Field Measurement 5.6GHz/5.6GHz/Hearing Aid Compatibility Test at 15mm
distance (41x181x1): Interpolated grid: dx=0.5000 mm, dy=0.5000 mm
Device Reference Point: 0, 0, -6.3 mm
Reference Value = 28.20 V/m; Power Drift = 0.02 dB
PMR not calibrated. PMF = 1.000 is applied.
E-field emissions = 103.5 V/m
Near-field category: M3 (AWF 0 dB)

                                         PMF scaled E-field
                                          Grid 1 M3 Grid 2 M3 Grid 3 M3
                                          83.91 V/m        84.89 V/m   81.77 V/m
                                          Grid 4 M3        Grid 5 M3   Grid 6 M3
                                          101.8 V/m        103.5 V/m   99.82 V/m
                                          Grid 7 M3        Grid 8 M3   Grid 9 M3
                                          81.94 V/m        83.36 V/m   80.61 V/m




                      0 dB = 103.5 V/m = 40.30 dBV/m

                                                                                                     Plot No. 5


Test Laboratory: UL Verification Services Inc. SAR Lab C                           Date: 6/13/2017

HAC-RF Emission
Communication System: UID 0, CW (0); Frequency: 5800 MHz; Duty Cycle: 1:1
Phantom section: RF Section
DASY5 Configuration:
- Probe: EF3DV3 - SN4041 (5-6 GHz); ConvF(1, 1, 1); Calibrated: 3/14/2017;
- Sensor-Surface: (Fix Surface)
- Electronics: DAE4 Sn1377; Calibrated: 9/14/2016
- Phantom: HAC Test Arch with AMCC; Type: SD HAC P01 BB
- Measurement SW: DASY52, Version 52.8 (7);SEMCAD X Version 14.6.10 (7164)

Dipole E-Field Measurement 5.8GHz/5.8 GHz/Hearing Aid Compatibility Test at 15mm
distance (41x181x1): Interpolated grid: dx=0.5000 mm, dy=0.5000 mm
Device Reference Point: 0, 0, -6.3 mm
Reference Value = 26.83 V/m; Power Drift = -0.00 dB
PMR not calibrated. PMF = 1.000 is applied.
E-field emissions = 105.5 V/m
Near-field category: M3 (AWF 0 dB)

                                         PMF scaled E-field
                                          Grid 1 M3 Grid 2 M3 Grid 3 M3
                                          85.93 V/m        87.13 V/m   83.95 V/m
                                          Grid 4 M3        Grid 5 M3   Grid 6 M3
                                          103.7 V/m        105.5 V/m   101.4 V/m
                                          Grid 7 M3        Grid 8 M3   Grid 9 M3
                                          80.48 V/m        81.55 V/m   78.29 V/m




                      0 dB = 105.5 V/m = 40.47 dBV/m

                                                                                                     Plot No. 6


Test Laboratory: UL Verification Services Inc. SAR Lab C                           Date: 7/13/2017

HAC-RF Emission
Communication System: UID 0, CW (0); Frequency: 2600 MHz; Duty Cycle: 1:1
Phantom section: RF Section
DASY5 Configuration:
- Probe: ER3DV6 - SN2509; ConvF(1, 1, 1); Calibrated: 5/12/2017;
- Sensor-Surface: (Fix Surface)
- Electronics: DAE4 Sn1377; Calibrated: 9/14/2016
- Phantom: HAC Test Arch with AMCC; Type: SD HAC P01 BB
- Measurement SW: DASY52, Version 52.8 (7);SEMCAD X Version 14.6.10 (7164)

Dipole E-Field Measurement 2600MHz/2600 MHz/Hearing Aid Compatibility Test at
15mm distance (41x181x1): Interpolated grid: dx=0.5000 mm, dy=0.5000 mm
Device Reference Point: 0, 0, -6.3 mm
Reference Value = 72.93 V/m; Power Drift = 0.01 dB
PMR not calibrated. PMF = 1.000 is applied.
E-field emissions = 85.06 V/m
Near-field category: M3 (AWF 0 dB)

                                         PMF scaled E-field
                                          Grid 1 M3 Grid 2 M3 Grid 3 M3
                                          76.81 V/m        77.87 V/m   76.68 V/m
                                          Grid 4 M3        Grid 5 M3   Grid 6 M3
                                          79.55 V/m        80.56 V/m   79.27 V/m
                                          Grid 7 M3        Grid 8 M3   Grid 9 M3
                                          84.27 V/m        85.06 V/m   83.02 V/m




                      0 dB = 85.06 V/m = 38.59 dBV/m

                                                                                                     Plot No. 7


Test Laboratory: UL Verification Services Inc. SAR Lab C                           Date: 7/14/2017

HAC-RF Emission
Communication System: UID 0, CW (0); Frequency: 5200 MHz; Duty Cycle: 1:1
Phantom section: RF Section
DASY5 Configuration:
- Probe: EF3DV3 - SN4041 (5-6 GHz); ConvF(1, 1, 1); Calibrated: 3/14/2017;
- Sensor-Surface: (Fix Surface)
- Electronics: DAE4 Sn1377; Calibrated: 9/14/2016
- Phantom: HAC Test Arch with AMCC; Type: SD HAC P01 BB
- Measurement SW: DASY52, Version 52.8 (7);SEMCAD X Version 14.6.10 (7164)

Dipole E-Field measurement 5.2GHz corrected grid/5.2GHz/Hearing Aid Compatibility
Test at 15mm distance (41x181x1): Interpolated grid: dx=0.5000 mm, dy=0.5000 mm
Device Reference Point: 0, 0, -6.3 mm
Reference Value = 26.15 V/m; Power Drift = 0.21 dB
PMR not calibrated. PMF = 1.000 is applied.
E-field emissions = 100.2 V/m
Near-field category: M3 (AWF 0 dB)

                                         PMF scaled E-field
                                          Grid 1 M3 Grid 2 M3 Grid 3 M3
                                          82.34 V/m        83.89 V/m   81.69 V/m
                                          Grid 4 M3        Grid 5 M3   Grid 6 M3
                                          98.19 V/m        100.2 V/m   97.48 V/m
                                          Grid 7 M3        Grid 8 M3   Grid 9 M3
                                          81.53 V/m        83.15 V/m   80.10 V/m




                      0 dB = 100.2 V/m = 40.02 dBV/m

                                                                                                     Plot No. 8



Document Created: 2017-07-18 00:44:56
Document Modified: 2017-07-18 00:44:56

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC