12289553-E1V2_FCC-IC Report BLE_Final _revised

FCC ID: BCG-B35

Test Report

Download: PDF
FCCID_4071460

     CERTIFICATION TEST REPORT
               Report Number. : 12289553-E1V2
      Applicant :     APPLE, INC.
                      1 APPLE PARK WAY
                      CUPERTINO, CA 95014, U.S.A.

         Model :      3.5

         FCC ID :     BCG-B35

             IC :     579C-B35

EUT Description :     SLEEP MONITOR

Test Standard(s) :    FCC 47 CFR PART 15 SUBPART C
                      ISED RSS-247 ISSUE 2
                      ISED RSS-GEN ISSUE 5



                             Date Of Issue:
                            October 30, 2018

                             Prepared by:
                       UL Verification Services Inc.
                          47173 Benicia Street
                       Fremont, CA 94538 U.S.A.
                          TEL: (510) 771-1000
                          FAX: (510) 661-0888




                     NVLAP Lab code: 200065-0


REPORT NO: 122589553-E1V2                                                                            DATE: 10/30/2018
FCC ID: BCG-B35                                                                                         IC: 579C-B35

REPORT REVISION HISTORY

             Issue
 Rev.        Date               Revisions                                                                Revised By
  V1         10/23/2018         Initial Issue                                                            Chin Pang
  V2         10/30/2018         Update Section 2 on KDB 414788                                           Chin Pang




                                            Page 2 of 45
UL VERIFICATION SERVICES INC.
47173 Benicia Street, Fremont, CA 94538; USA            TEL:(510) 771-1000                         FAX:(510) 661-0888
This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc.


REPORT NO: 122589553-E1V2                                                                                   DATE: 10/30/2018
FCC ID: BCG-B35                                                                                                IC: 579C-B35
                                            TABLE OF CONTENTS
REPORT REVISION HISTORY ................................................................................................. 2

TABLE OF CONTENTS ............................................................................................................ 3

1.     ATTESTATION OF TEST RESULTS ................................................................................. 5

2.     TEST METHODOLOGY ..................................................................................................... 6

3.     FACILITIES AND ACCREDITATION ................................................................................. 6

4.     CALIBRATION AND UNCERTAINTY ................................................................................ 7
     4.1.   MEASURING INSTRUMENT CALIBRATION .............................................................. 7
     4.2.   SAMPLE CALCULATION ............................................................................................ 7
     4.3.   MEASUREMENT UNCERTAINTY ............................................................................... 7

5.     EQUIPMENT UNDER TEST ............................................................................................... 8
     5.1.   EUT DESCRIPTION .................................................................................................... 8
     5.2.   MAXIMUM OUTPUT POWER...................................................................................... 8
     5.3.   DESCRIPTION OF AVAILABLE ANTENNAS .............................................................. 8
     5.4.   SOFTWARE AND FIRMWARE .................................................................................... 8
     5.5.   WORST-CASE CONFIGURATION AND MODE .......................................................... 8
     5.6.   DESCRIPTION OF TEST SETUP ................................................................................ 9

6.     MEASUREMENT METHOD...............................................................................................13

7.     TEST AND MEASUREMENT EQUIPMENT ......................................................................14

8.     ANTENNA PORT TEST RESULTS ...................................................................................15
     8.1.   ON TIME AND DUTY CYCLE .....................................................................................15
     8.2.   99% BANDWIDTH ......................................................................................................17
     8.3.   6 dB BANDWIDTH ......................................................................................................19
     8.4.   OUTPUT POWER.......................................................................................................21
     8.5.   AVERAGE POWER ....................................................................................................22
     8.6.   POWER SPECTRAL DENSITY ..................................................................................23
     8.7.   CONDUCTED SPURIOUS EMISSIONS .....................................................................25

9.     RADIATED TEST RESULTS .............................................................................................27
     9.1.   LIMITS AND PROCEDURE ........................................................................................27
     9.2.   TRANSMITTER ABOVE 1 GHz ..................................................................................28
     9.3.   WORST CASE BELOW 1 GHz ...................................................................................38
     9.4.   WORST CASE ABOVE 18-26 GHz ............................................................................40
                                            Page 3 of 45
UL VERIFICATION SERVICES INC.
47173 Benicia Street, Fremont, CA 94538; USA            TEL:(510) 771-1000                                FAX:(510) 661-0888
This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc.


REPORT NO: 122589553-E1V2                                                                                  DATE: 10/30/2018
FCC ID: BCG-B35                                                                                               IC: 579C-B35
10.     AC POWER LINE CONDUCTED EMISSIONS ..............................................................42

11.     SETUP PHOTOS ...........................................................................................................45




                                            Page 4 of 45
UL VERIFICATION SERVICES INC.
47173 Benicia Street, Fremont, CA 94538; USA            TEL:(510) 771-1000                               FAX:(510) 661-0888
This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc.


REPORT NO: 122589553-E1V2                                                                            DATE: 10/30/2018
FCC ID: BCG-B35                                                                                         IC: 579C-B35

1. ATTESTATION OF TEST RESULTS
COMPANY NAME:                        APPLE, INC.
                                     1 APPLE PARK WAY
                                     CUPERTINO, CA 95014, U.S.A.

EUT DESCRIPTION:                     SLEEP MONITOR

MODEL:                               3.5

SERIAL NUMBER:                       DLC8364003YJQJT13, DLC8364003SJQJT19

DATE TESTED:                         SEPTEMBER 21 – OCTOBER 17, 2018

                                           APPLICABLE STANDARDS
                                STANDARD                                                 TEST RESULTS
                        CFR 47 Part 15 Subpart C                                             Complies
                          ISED RSS-247 Issue 2                                               Complies
                         ISED RSS-GEN Issue 5                                                Complies


UL Verification Services Inc. tested the above equipment in accordance with the requirements
set forth in the above standards. The test results show that the equipment tested is capable of
demonstrating compliance with the requirements as documented in this report.

The results documented in this report apply only to the tested sample, under the conditions and
modes of operation as described herein. It is the manufacturer's responsibility to assure that
additional production units of this model are manufactured with identical electrical and
mechanical components. All samples tested were in good operating condition throughout the
entire test program. Measurement Uncertainties are published for informational purposes only
and were not taken into account unless noted otherwise.

This document may not be altered or revised in any way unless done so by UL Verification
Services Inc. and all revisions are duly noted in the revisions section. Any alteration of this
document not carried out by UL Verification Services Inc. will constitute fraud and shall nullify
the document. This report must not be used by the client to claim product certification,
approval, or endorsement by NVLAP, NIST, any agency of the Federal Government, or any
agency of the U.S. government.

Approved & Released For
UL Verification Services Inc. By:                                 Prepared By:




Chin Pang                                                        Mona Hua
Senior Engineer                                                  Lab Engineer
UL Verification Services Inc.                                    UL Verification Services Inc

                                            Page 5 of 45
UL VERIFICATION SERVICES INC.
47173 Benicia Street, Fremont, CA 94538; USA            TEL:(510) 771-1000                         FAX:(510) 661-0888
This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc.


REPORT NO: 122589553-E1V2                                                                            DATE: 10/30/2018
FCC ID: BCG-B35                                                                                         IC: 579C-B35
2. TEST METHODOLOGY
The tests documented in this report were performed in accordance with FCC CFR 47 Part 2,
FCC CFR 47 Part 15, KDB 558074 D01 v05, KDB 414788 for testing <30MHz, ANSI C63.10-
2013, RSS-GEN Issue 5, and RSS-247 Issue 2.

3. FACILITIES AND ACCREDITATION
The test sites and measurement facilities used to collect data are located at 47173 and 47266
Benicia Street, and 47658 Kato Road, Fremont, California, USA. Line conducted emissions are
measured only at the 47173 address. The following table identifies which facilities were utilized
for radiated emission measurements documented in this report. Specific facilities are also
identified in the test results sections.

      47173 Benicia Street                     47266 Benicia Street                          47658 Kato Rd
            Chamber A                                Chamber D                                  Chamber K
        (ISED:2324B-1)                           (ISED:22541-1)                             (ISED:2324A-1)
            Chamber B                                Chamber E                                  Chamber L
        (ISED:2324B-2)                           (ISED:22541-2)                             (ISED:2324A-3)
            Chamber C                                Chamber F
        (ISED:2324B-3)                           (ISED:22541-3)
                                                     Chamber G
                                                 (ISED:22541-4)
                                                     Chamber H
                                                 (ISED:22541-5)

The above test sites and facilities are covered under FCC Test Firm Registration # 208313.
Chambers A through C are covered under ISED company address code 2324B with site
numbers 2324B -1 through 2324B-3, respectively. Chambers D through H are covered under
ISED company address code 22541 with site numbers 22541 -1 through 22541-5, respectively.
Chambers K and L are covered under ISED company address code 2324A with site numbers
2324A-1 and 2324A-3, respectively.

UL Verification Services Inc. is accredited by NVLAP, Laboratory Code 200065-0. The full
scope of accreditation can be viewed at NVLAP Lab Search.




                                            Page 6 of 45
UL VERIFICATION SERVICES INC.
47173 Benicia Street, Fremont, CA 94538; USA            TEL:(510) 771-1000                         FAX:(510) 661-0888
This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc.


REPORT NO: 122589553-E1V2                                                                            DATE: 10/30/2018
FCC ID: BCG-B35                                                                                         IC: 579C-B35
4. CALIBRATION AND UNCERTAINTY
    4.1.          MEASURING INSTRUMENT CALIBRATION
The measuring equipment utilized to perform the tests documented in this report has been
calibrated in accordance with the manufacturer's recommendations, and is traceable to
recognized national standards.

    4.2.          SAMPLE CALCULATION
Where relevant, the following sample calculation is provided:
      Field Strength (dBuV/m) = Measured Voltage (dBuV) + Antenna Factor (dB/m) +
      Cable Loss (dB) – Preamp Gain (dB)
      36.5 dBuV + 18.7 dB/m + 0.6 dB – 26.9 dB = 28.9 dBuV/m


    4.3.          MEASUREMENT UNCERTAINTY
Where relevant, the following measurement uncertainty levels have been estimated for tests
performed on the apparatus:

                  PARAMETER                              UNCERTAINTY
 Worst Case Conducted Disturbance,
                                                       3.84 dB
 9KHz to 0.15 MHz
 Worst Case Conducted Disturbance,
                                                       3.65 dB
 0.15 to 30 MHz
 Worst Case Radiated Disturbance,
                                                       3.15 dB
 9KHz to 30 MHz
 Worst Case Radiated Disturbance, 30
                                                       5.36 dB
 to 1000 MHz
 Worst Case Radiated Disturbance,
                                                       4.32 dB
 1000 to 18000 MHz
 Worst Case Radiated Disturbance,
                                                       4.45 dB
 18000 to 26000 MHz
 Worst Case Radiated Disturbance,
                                                       5.24 dB
 26000 to 40000 MHz

Uncertainty figures are valid to a confidence level of 95%.




                                            Page 7 of 45
UL VERIFICATION SERVICES INC.
47173 Benicia Street, Fremont, CA 94538; USA            TEL:(510) 771-1000                         FAX:(510) 661-0888
This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc.


REPORT NO: 122589553-E1V2                                                                            DATE: 10/30/2018
FCC ID: BCG-B35                                                                                         IC: 579C-B35
5. EQUIPMENT UNDER TEST
    5.1.          EUT DESCRIPTION
The EUT is a sleep monitor with Bluetooth LE Radio and integrated antenna. It has no battery. It
is powered by USB-A connector.

    5.2.          MAXIMUM OUTPUT POWER

The transmitter has a maximum peak conducted output power as follows:

  Frequency             Mode            Output Power          Output Power
    Range                                  (dBm)                 (mW)
    (MHz)
  2402 - 2480            BLE                  5.02                   3.18


    5.3.          DESCRIPTION OF AVAILABLE ANTENNAS

     Frequency                 Ant.
    Range (GHz)                (dBi)
           2.4                 -2.1


    5.4.          SOFTWARE AND FIRMWARE
The EUT firmware installed during testing was v004ef1.


    5.5.          WORST-CASE CONFIGURATION AND MODE
The EUT was investigated in three orthogonal orientations X, Y and Z and it was determined
that Y(Landscape) orientation was the worst-case orientation.

Radiated emissions below 30MHz, below 1GHz, 1-18GHz & 18-26GHz and power line
conducted emissions were performed with the EUT connected to an AC power adapter
transmitting at the channel with the highest output power as the worst-case scenario.

There was no emission found below 30MHz within 20dB of the limit.




                                            Page 8 of 45
UL VERIFICATION SERVICES INC.
47173 Benicia Street, Fremont, CA 94538; USA            TEL:(510) 771-1000                         FAX:(510) 661-0888
This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc.


REPORT NO: 122589553-E1V2                                                                            DATE: 10/30/2018
FCC ID: BCG-B35                                                                                         IC: 579C-B35
    5.6.          DESCRIPTION OF TEST SETUP
SUPPORT EQUIPMENT
                                   Support Equipment List
      Description        Manufacturer       Model            Serial Number                                           FCC ID
        Laptop              Apple       Macbook Pro          C02P41RZG086                                           FCC DoC
 Laptop AC/DC adapter Liteon Technology      A1343        C062172045DDJ94A6                                           NA
    EUT AC Adapter          Apple            A1385      D293154U2DTDHLHCW                                             NA
        iPhone              Apple           AXXXX           C39N80EZG5QM                                            FCC DoC
    Interface Board           NA              NA                   NA                                                 NA


I/O CABLES (CONDUCTED TEST)
                                                  I/O Cable List
 Cable          Port          # of identical Connector    Cable Type                   Cable                 Remarks
  No                              ports        Type                                  Length (m)
   1         Antenna                 1               SMA            Shielded             0.3         To Spectrum Analyzer
   2           USB                   1               USB            Shielded              1                   NA
   3     AC/DC Adapter               1             2-Prong          Shielded              2                   NA
   4     Interface Board            NA                NA               NA                NA                   NA


I/O CABLES (RADIATED AND CONDUCTED EMISSIONS)

                                             I/O Cable List
 Cable       Port      # of identical Connector Cable Type                      Cable                 Remarks
  No                       ports        Type                                  Length (m)
    1         USB              1              USB            Shielded               1                    NA


TEST SETUP

The EUT is connected to a test laptop during the tests. Test software exercised the EUT.




                                            Page 9 of 45
UL VERIFICATION SERVICES INC.
47173 Benicia Street, Fremont, CA 94538; USA            TEL:(510) 771-1000                         FAX:(510) 661-0888
This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc.


REPORT NO: 122589553-E1V2                                                                            DATE: 10/30/2018
FCC ID: BCG-B35                                                                                         IC: 579C-B35
SETUP DIAGRAM FOR CONDUCTED TESTS
The EUT was tested connected to a host Laptop via USB cable adapter and spectrum analyzer
to antenna port. Test software exercised the EUT.




                                           Page 10 of 45
UL VERIFICATION SERVICES INC.
47173 Benicia Street, Fremont, CA 94538; USA           TEL:(510) 771-1000                          FAX:(510) 661-0888
This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc.


REPORT NO: 122589553-E1V2                                                                            DATE: 10/30/2018
FCC ID: BCG-B35                                                                                         IC: 579C-B35
SETUP DIAGRAM FOR RADIATED TESTS ABOVE 1 GHz




                                           Page 11 of 45
UL VERIFICATION SERVICES INC.
47173 Benicia Street, Fremont, CA 94538; USA           TEL:(510) 771-1000                          FAX:(510) 661-0888
This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc.


REPORT NO: 122589553-E1V2                                                                            DATE: 10/30/2018
FCC ID: BCG-B35                                                                                         IC: 579C-B35
SETUP DIAGRAM FOR Below 1GHz and AC LINE CONDUCTED TEST




                                           Page 12 of 45
UL VERIFICATION SERVICES INC.
47173 Benicia Street, Fremont, CA 94538; USA           TEL:(510) 771-1000                          FAX:(510) 661-0888
This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc.


REPORT NO: 122589553-E1V2                                                                            DATE: 10/30/2018
FCC ID: BCG-B35                                                                                         IC: 579C-B35
6. MEASUREMENT METHOD
On Time and Duty Cycle: KDB 558074 D01 v05, Section 6.

6 dB BW: KDB 558074 D01 v05, Section 8.1.

Output Power: KDB 558074 D01 v05, Section 9.1.3.

Power Spectral Density: KDB 558074 D01 v05, Section 10.2.

Out-of-band emissions in non-restricted bands: KDB 558074 D01 v05, Section 11.0.

Out-of-band emissions in restricted bands: KDB 558074 D01 v05, Section 12.1.

Band-edge: KDB 558074 D01 v05, Section 12.1.

AC Power Line Conducted Emissions: ANSI C63.10-2013, Section 6.2.




                                           Page 13 of 45
UL VERIFICATION SERVICES INC.
47173 Benicia Street, Fremont, CA 94538; USA           TEL:(510) 771-1000                          FAX:(510) 661-0888
This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc.


   REPORT NO: 122589553-E1V2                                                                            DATE: 10/30/2018
   FCC ID: BCG-B35                                                                                         IC: 579C-B35
   7. TEST AND MEASUREMENT EQUIPMENT
   The following test and measurement equipment was utilized for the tests documented in this
   report:

       Description                Manufacturer                      Model                      ID Num              Cal Due
   Amplifier, 1 to 18GHz                Miteq             AFS42-00101800-25-S-42                 T742             12/04/2018
  Antenna, Horn 1-18GHz            ETS-Lindgren                    3117                          T711             01/30/2019
    Pre-Amp 18-26GHz             Agilent Technology               8449B                          T404             03/09/2019
 Antenna Horn 18-26GHz                   ARA                    MWH-1826                         T89              01/18/2019
 Amplifier, 10KHz to 1GHz,
                                Sonoma Instrument                    310                         T173             07/06/2019
            32dB
Antenna, Broadband Hybrid,
                                  Sunol Sciences                     JB3                         T408             12/15/2018
    30MHz to 2000MHz
 Spectrum Analyzer, PXA,         Agilent (Keysight)
                                                                 N9030A-544                     T1210             08/06/2019
       3Hz to 44GHz                Technologies
 Spectrum Analyzer, PSA
                                      Keysight                     E4446A                        T99              06/27/2019
       3Hz to 44GHz
Power Meter, P-series single
                                      Keysight                     N1911A                       T1245             04/05/2019
           channel
       Power Sensor                   Keysight                     N1921A                       T1228             07/10/2019
                                                      AC Line Conducted
    EMI Test Receiver            Rohde & Schwarz                     ESR                        T1436             02/23/2019
   LISN for Conducted
                                       Fischer                 50/250-25-2-01                   T1310             06/19/2019
   Emissions CISPR-16
                                              UL AUTOMATION SOFTWARE
     Radiated Software                   UL                        UL EMC                       Ver 9.5, April 26, 2016
    Conducted Software                   UL                        UL EMC                      Ver 5.4, October 13, 2016
    AC Line Conducted                    UL                        UL EMC                       Ver 9.5, May 26, 2015
         Software




                                              Page 14 of 45
   UL VERIFICATION SERVICES INC.
   47173 Benicia Street, Fremont, CA 94538; USA           TEL:(510) 771-1000                           FAX:(510) 661-0888
   This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc.


REPORT NO: 122589553-E1V2                                                                            DATE: 10/30/2018
FCC ID: BCG-B35                                                                                         IC: 579C-B35
8. ANTENNA PORT TEST RESULTS

    8.1.          ON TIME AND DUTY CYCLE
LIMITS

None; for reporting purposes only.

PROCEDURE

ON TIME AND DUTY CYCLE RESULTS

            Mode                ON Time      Period     Duty Cycle       Duty          Duty Cycle              1/B
                                   B                         x           Cycle      Correction Factor     Minimum VBW
                                 (msec)      (msec)      (linear)         (%)             (dB)                (kHz)
2.4GHz Band
BLE                               0.431      0.627         0.687       68.67%              1.63                 2.323




                                           Page 15 of 45
UL VERIFICATION SERVICES INC.
47173 Benicia Street, Fremont, CA 94538; USA           TEL:(510) 771-1000                          FAX:(510) 661-0888
This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc.


REPORT NO: 122589553-E1V2                                                                            DATE: 10/30/2018
FCC ID: BCG-B35                                                                                         IC: 579C-B35
DUTY CYCLE PLOTS




                                                DUTY CYCLE BLE




                                           Page 16 of 45
UL VERIFICATION SERVICES INC.
47173 Benicia Street, Fremont, CA 94538; USA           TEL:(510) 771-1000                          FAX:(510) 661-0888
This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc.


REPORT NO: 122589553-E1V2                                                                            DATE: 10/30/2018
FCC ID: BCG-B35                                                                                         IC: 579C-B35
    8.2.          99% BANDWIDTH

LIMITS

None; for reporting purposes only.

RESULTS




                                           Page 17 of 45
UL VERIFICATION SERVICES INC.
47173 Benicia Street, Fremont, CA 94538; USA           TEL:(510) 771-1000                          FAX:(510) 661-0888
This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc.


REPORT NO: 122589553-E1V2                                                                            DATE: 10/30/2018
FCC ID: BCG-B35                                                                                         IC: 579C-B35

                              Channel            Frequency             99% Bandwidth
                                                   (MHz)                   (MHz)
                                 Low                2402                   1.0203
                                Middle              2440                   1.0056
                                 High               2480                   1.0237




                   LOW CHANNEL                                                    MID CHANNEL




                                                  HIGH CHANNEL




                                           Page 18 of 45
UL VERIFICATION SERVICES INC.
47173 Benicia Street, Fremont, CA 94538; USA           TEL:(510) 771-1000                          FAX:(510) 661-0888
This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc.


REPORT NO: 122589553-E1V2                                                                            DATE: 10/30/2018
FCC ID: BCG-B35                                                                                         IC: 579C-B35
    8.3.          6 dB BANDWIDTH

LIMITS

FCC §15.407 (e)

RSS-247 5.2 (a)

The minimum 6 dB bandwidth shall be at least 500 kHz.

RESULTS




                                           Page 19 of 45
UL VERIFICATION SERVICES INC.
47173 Benicia Street, Fremont, CA 94538; USA           TEL:(510) 771-1000                          FAX:(510) 661-0888
This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc.


REPORT NO: 122589553-E1V2                                                                            DATE: 10/30/2018
FCC ID: BCG-B35                                                                                         IC: 579C-B35

                 Channel           Frequency            6 dB Bandwidth             Minimum Limit
                                     (MHz)                   (MHz)                     (MHz)
                    Low                2402                    0.7200                       0.5
                   Middle              2440                    0.6930                       0.5
                    High               2480                    0.6930                       0.5




                   LOW CHANNEL                                                    MID CHANNEL




                                                  HIGH CHANNEL




                                           Page 20 of 45
UL VERIFICATION SERVICES INC.
47173 Benicia Street, Fremont, CA 94538; USA           TEL:(510) 771-1000                          FAX:(510) 661-0888
This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc.


REPORT NO: 122589553-E1V2                                                                            DATE: 10/30/2018
FCC ID: BCG-B35                                                                                         IC: 579C-B35
    8.4.          OUTPUT POWER

LIMITS

FCC §15.247 (b) (3)

RSS-247 5.4 (d)

The maximum antenna gain is less than or equal to 6 dBi, therefore the limit is 30 dBm.

TEST PROCEDURE
The transmitter output is connected to a power meter.

The cable assembly insertion loss of 10.7 dB (including 10 dB pad and 0.7 dB cable) was
entered as an offset in the power meter to allow for a gated peak reading of power.

RESULTS



           Tested By:                   38806
           Date:                   10/11/2018

             Channel           Frequency             Peak Power                 Limit            Margin
                                                      Reading
                                  (MHz)                (dBm)                   (dBm)               (dB)
                Low                2402                 5.02                     30               -24.98
               Middle              2440                 5.02                     30               -24.98
                High               2480                 5.01                     30               -24.99




                                           Page 21 of 45
UL VERIFICATION SERVICES INC.
47173 Benicia Street, Fremont, CA 94538; USA           TEL:(510) 771-1000                          FAX:(510) 661-0888
This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc.


REPORT NO: 122589553-E1V2                                                                            DATE: 10/30/2018
FCC ID: BCG-B35                                                                                         IC: 579C-B35
    8.5.          AVERAGE POWER

LIMITS

None; for reporting purposes only.

TEST PROCEDURE
The transmitter output is connected to a power meter.

The cable assembly insertion loss of 10.7 dB (including 10 dB pad and 0.7 dB cable) was
entered as an offset in the power meter to allow for a gated average reading of power.


RESULTS



                              Tested By:                     38806
                              Date:                     10/11/2018

                                  Channel            Frequency            AV power
                                                       (MHz)               (dBm)
                                    Low                 2402                4.95
                                   Middle               2440                4.95
                                    High                2480                4.92




                                           Page 22 of 45
UL VERIFICATION SERVICES INC.
47173 Benicia Street, Fremont, CA 94538; USA           TEL:(510) 771-1000                          FAX:(510) 661-0888
This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc.


REPORT NO: 122589553-E1V2                                                                            DATE: 10/30/2018
FCC ID: BCG-B35                                                                                         IC: 579C-B35
    8.6.          POWER SPECTRAL DENSITY
LIMITS

FCC §15.247 (e)

RSS-247 (5.2) (b)

The power spectral density conducted from the transmitter to the antenna shall not be greater
than 8 dBm in any 3 kHz band during any time interval of continuous transmission.

RESULTS




                                           Page 23 of 45
UL VERIFICATION SERVICES INC.
47173 Benicia Street, Fremont, CA 94538; USA           TEL:(510) 771-1000                          FAX:(510) 661-0888
This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc.


REPORT NO: 122589553-E1V2                                                                            DATE: 10/30/2018
FCC ID: BCG-B35                                                                                         IC: 579C-B35

             Channel          Frequency    PSD                          Limit                  Margin
                                (MHz)   (dBm/3kHz)                   (dBm/3kHz)                 (dB)
                Low              2402      -7.62                          8                    -15.62
               Middle            2440      -7.60                          8                    -15.60
                High             2480      -8.85                          8                    -16.85




                   LOW CHANNEL                                                    MID CHANNEL




                                                  HIGH CHANNEL




                                           Page 24 of 45
UL VERIFICATION SERVICES INC.
47173 Benicia Street, Fremont, CA 94538; USA           TEL:(510) 771-1000                          FAX:(510) 661-0888
This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc.


REPORT NO: 122589553-E1V2                                                                            DATE: 10/30/2018
FCC ID: BCG-B35                                                                                         IC: 579C-B35
    8.7.          CONDUCTED SPURIOUS EMISSIONS
LIMITS

FCC §15.247 (d)

RSS-247 5.5

Output power was measured based on the use of a peak measurement, therefore the required
attenuation is 20 dB.

RESULTS




                                           Page 25 of 45
UL VERIFICATION SERVICES INC.
47173 Benicia Street, Fremont, CA 94538; USA           TEL:(510) 771-1000                          FAX:(510) 661-0888
This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc.


REPORT NO: 122589553-E1V2                                                                            DATE: 10/30/2018
FCC ID: BCG-B35                                                                                         IC: 579C-B35




          LOW CHANNEL BANDEDGE                                         OUT-OF-BAND LOW CHANNEL




         IN-BAND REFERENCE LEVEL                                       OUT-OF-BAND MID CHANNEL




          HIGH CHANNEL BANDEDGE                                       OUT-OF-BAND HIGH CHANNEL




                                           Page 26 of 45
UL VERIFICATION SERVICES INC.
47173 Benicia Street, Fremont, CA 94538; USA           TEL:(510) 771-1000                          FAX:(510) 661-0888
This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc.


REPORT NO: 122589553-E1V2                                                                            DATE: 10/30/2018
FCC ID: BCG-B35                                                                                         IC: 579C-B35
9. RADIATED TEST RESULTS

    9.1.          LIMITS AND PROCEDURE
LIMITS

FCC §15.205 and §15.209

RSS-GEN, Section 8.9 and 8.10.

   Frequency Range               Field Strength Limit             Field Strength Limit
         (MHz)                      (uV/m) at 3 m                   (dBuV/m) at 3 m
      0.009-0.490                2400/F(kHz) @ 300 m                        -
      0.490-1.705                24000/F(kHz) @ 30 m                        -
       1.705 - 30                     30 @ 30m                              -
         30 - 88                          100                              40
        88 - 216                          150                             43.5
       216 - 960                          200                              46
      Above 960                           500                              54

TEST PROCEDURE

The EUT is placed on a non-conducting table 80 cm above the ground plane for measurement
below 1GHz; 1.5 m above the ground plane for measurement above 1GHz. The antenna to EUT
distance is 3 meters. The EUT is configured in accordance with ANSI C63.10. The EUT is set to
transmit in a continuous mode.

For measurements below 1 GHz the resolution bandwidth is set to 100 kHz for peak detection
measurements or 120 kHz for quasi-peak detection measurements. Peak detection is used
unless otherwise noted as quasi-peak.

For pre-scans above 1 GHz the resolution bandwidth is set to 1 MHz; the video bandwidth is set
to 30 KHz for peak measurements.

For final measurements above 1 GHz the resolution bandwidth is set to 1 MHz; the video
bandwidth is set to 3 MHz for peak measurements and as applicable for average
measurements.

The spectrum from 1 GHz to 18 GHz is investigated with the transmitter set to the lowest,
middle, and highest channels in each applicable band. Below 1GHz and above 18GHz
emissions, the channel with the highest output power was tested.

The frequency range of interest is monitored at a fixed antenna height and EUT azimuth. The
EUT is rotated through 360 degrees to maximize emissions received. The antenna is scanned
from 1 to 4 meters above the ground plane to further maximize the emission. Measurements are
made with the antenna polarized in both the vertical and the horizontal positions.




                                           Page 27 of 45
UL VERIFICATION SERVICES INC.
47173 Benicia Street, Fremont, CA 94538; USA           TEL:(510) 771-1000                          FAX:(510) 661-0888
This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc.


      REPORT NO: 122589553-E1V2                                                                                             DATE: 10/30/2018
      FCC ID: BCG-B35                                                                                                          IC: 579C-B35
          9.2.            TRANSMITTER ABOVE 1 GHz


      BANDEDGE (LOW CHANNEL)

                                                       HORIZONTAL RESULT




Marker     Frequency    Meter    Det     AF     Amp/Cbl/Fltr/   DC Corr   Corrected    Average   Margin   Peak Limit     PK     Azimuth   Height   Polarity
             (GHz)     Reading          T711     Pad (dB)        (dB)      Reading      Limit     (dB)    (dBuV/m)     Margin    (Degs)    (cm)
                       (dBuV)          (dB/m)                             (dBuV/m)    (dBuV/m)                          (dB)
  1         * 2.39     39.09      Pk   32.1        -20.6           0       50.59         -          -        74        -23.41    139      168        H
  2        * 2.336     44.04      Pk   31.9        -20.7           0       55.24         -          -        74        -18.76    139      168        H
  3         * 2.39     29.79     RMS   32.1        -20.6         1.63      42.92        54       -11.08       -           -      139      168        H
  4        * 2.378     30.94     RMS   32.1        -20.6         1.63      44.07        54        -9.93       -           -      139      168        H


      * - indicates frequency in CFR47 Pt 15 / IC RSS-Restricted Band
      Pk - Peak detector
      RMS - RMS detection




                                                 Page 28 of 45
      UL VERIFICATION SERVICES INC.
      47173 Benicia Street, Fremont, CA 94538; USA           TEL:(510) 771-1000                                          FAX:(510) 661-0888
      This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc.


 REPORT NO: 122589553-E1V2                                                                                                  DATE: 10/30/2018
 FCC ID: BCG-B35                                                                                                               IC: 579C-B35

                                                          VERTICAL RESULT




Marker   Frequency    Meter    Det     AF     Amp/Cbl/Fltr/Pad    DC    Corrected    Average   Margin   Peak Limit   PK Margin   Azimuth   Height   Polarity
           (GHz)     Reading          T711         (dB)          Corr    Reading      Limit     (dB)    (dBuV/m)       (dB)       (Degs)    (cm)
                     (dBuV)          (dB/m)                      (dB)   (dBuV/m)    (dBuV/m)
  1       * 2.39     38.97      Pk   32.1         -20.6            0     50.47         -          -        74        -23.53       359      132        V
  2      * 2.385     41.6       Pk   32.1         -20.6            0     53.1          -          -        74         -20.9       359      132        V
  3       * 2.39     29.41     RMS   32.1         -20.6          1.63    42.54        54       -11.46       -           -         359      132        V
  4      * 2.381     30.88     RMS   32.1         -20.6          1.63    44.01        54        -9.99       -           -         359      132        V


 * - indicates frequency in CFR47 Pt 15 / IC RSS-Restricted Band
 Pk - Peak detector
 RMS - RMS detection




                                            Page 29 of 45
 UL VERIFICATION SERVICES INC.
 47173 Benicia Street, Fremont, CA 94538; USA           TEL:(510) 771-1000                                              FAX:(510) 661-0888
 This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc.


 REPORT NO: 122589553-E1V2                                                                                                 DATE: 10/30/2018
 FCC ID: BCG-B35                                                                                                              IC: 579C-B35
 BANDEDGE (HIGH CHANNEL)

                                                       HORIZONTAL RESULT




Marker   Frequency    Meter    Det   AF T711   Amp/Cbl/Fltr/Pad    DC    Corrected    Average   Margin   Peak Limit     PK     Azimuth   Height   Polarity
           (GHz)     Reading          (dB/m)        (dB)          Corr    Reading      Limit     (dB)    (dBuV/m)     Margin    (Degs)    (cm)
                     (dBuV)                                       (dB)   (dBuV/m)    (dBuV/m)                          (dB)
  1      * 2.484     42.7       Pk    32.4         -20.7            0     54.4          -          -        74         -19.6    253      134        H
  2      * 2.484     42.95      Pk    32.4         -20.7            0     54.65         -          -        74        -19.35    253      134        H
  3      * 2.484     30.16     RMS    32.4         -20.7          1.63    43.49        54       -10.51       -           -      253      134        H
  4       2.503      31.39     RMS    32.4         -20.7          1.63    44.72        54        -9.28       -           -      253      134        H


 * - indicates frequency in CFR47 Pt 15 / IC RSS-Restricted Band
 Pk - Peak detector
 RMS - RMS detection




                                            Page 30 of 45
 UL VERIFICATION SERVICES INC.
 47173 Benicia Street, Fremont, CA 94538; USA           TEL:(510) 771-1000                                              FAX:(510) 661-0888
 This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc.


 REPORT NO: 122589553-E1V2                                                                                                    DATE: 10/30/2018
 FCC ID: BCG-B35                                                                                                                 IC: 579C-B35

                                                          VERTICAL RESULT




Marker   Frequency    Meter    Det     AF     Amp/Cbl/Fltr/Pad    DC    Corrected    Average   Margin   Peak Limit     PK       Azimuth   Height   Polarity
           (GHz)     Reading          T711         (dB)          Corr    Reading      Limit     (dB)    (dBuV/m)     Margin      (Degs)    (cm)
                     (dBuV)          (dB/m)                      (dB)   (dBuV/m)    (dBuV/m)                          (dB)
  1      * 2.484     41.96      Pk   32.4         -20.7            0     53.66         -          -        74        -20.34      128      168        V
  2       2.516      44.53      Pk   32.4         -20.6            0     56.33         -          -        74        -17.67      128      168        V
  3      * 2.484     30.39     RMS   32.4         -20.7          1.63    43.72        54       -10.28       -           -        128      168        V
  4      * 2.484     31.43     RMS   32.4         -20.7          1.63    44.76        54        -9.24       -           -        128      168        V


 * - indicates frequency in CFR47 Pt 15 / IC RSS-Restricted Band
 Pk - Peak detector
 RMS - RMS detection




                                            Page 31 of 45
 UL VERIFICATION SERVICES INC.
 47173 Benicia Street, Fremont, CA 94538; USA           TEL:(510) 771-1000                                             FAX:(510) 661-0888
 This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc.


REPORT NO: 122589553-E1V2                                                                            DATE: 10/30/2018
FCC ID: BCG-B35                                                                                         IC: 579C-B35
HARMONICS AND SPURIOUS EMISSIONS

                                         LOW CHANNEL RESULTS




                                                  HORIZTONAL




                                                     VERTICAL




                                           Page 32 of 45
UL VERIFICATION SERVICES INC.
47173 Benicia Street, Fremont, CA 94538; USA           TEL:(510) 771-1000                          FAX:(510) 661-0888
This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc.


 REPORT NO: 122589553-E1V2                                                                                                       DATE: 10/30/2018
 FCC ID: BCG-B35                                                                                                                    IC: 579C-B35

                                                        RADIATED EMISSIONS
Marker   Frequency    Meter     Det     AF     Amp/Cbl/Fltr/Pad   DC Corr   Corrected   Avg Limit   Margin     Peak       PK       Azimuth   Height   Polarity
           (GHz)     Reading           T711         (dB)           (dB)      Reading    (dBuV/m)     (dB)      Limit    Margin      (Degs)    (cm)
                     (dBuV)           (dB/m)                                (dBuV/m)                         (dBuV/m)    (dB)
  1      * 2.379     43.77     PK2    32.1         -20.6             0       55.27         -           -       74       -18.73      345      151        H
         * 2.379     30.31     MAv1   32.1         -20.6           1.63      43.44        54        -10.56      -          -        345      151        H
  2        2.44      46.58     PK2    32.4         -20.6             0       58.38         -           -        -          -        154      123        H
  3        2.44      48.9      PK2    32.4         -20.6             0       60.7          -           -        -          -         22      100        V
  4      * 2.379     47.43     PK2    32.1         -20.6             0       58.93         -           -       74       -15.07       24      103        V
         * 2.379     31.44     MAv1   32.1         -20.6           1.63      44.57        54         -9.43      -          -         24      103        V
  5      * 2.323     46.48     PK2    31.8         -20.6             0       57.68         -           -       74       -16.32      134      104        V
         * 2.323     30.54     MAv1   31.8         -20.6           1.63      43.37        54        -10.63      -          -        134      104        V
  6       7.205      40.57     PK2    35.6         -25.6             0       50.57         -           -        -          -        220      198        V
  7       9.607      38.28     PK2    36.5         -21.5             0       53.28         -           -        -          -        302      179        V


 * - indicates frequency in CFR47 Pt 15 / IC RSS-Restricted Band
 PK2 - KDB558074 Method: Maximum Peak
 MAv1 - KDB558074 Option 1 Maximum RMS Average




                                            Page 33 of 45
 UL VERIFICATION SERVICES INC.
 47173 Benicia Street, Fremont, CA 94538; USA           TEL:(510) 771-1000                                                FAX:(510) 661-0888
 This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc.


REPORT NO: 122589553-E1V2                                                                            DATE: 10/30/2018
FCC ID: BCG-B35                                                                                         IC: 579C-B35
                                          MID CHANNEL RESULTS




                                                  HORIZTONAL




                                                     VERTICAL




                                           Page 34 of 45
UL VERIFICATION SERVICES INC.
47173 Benicia Street, Fremont, CA 94538; USA           TEL:(510) 771-1000                          FAX:(510) 661-0888
This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc.


 REPORT NO: 122589553-E1V2                                                                                                 DATE: 10/30/2018
 FCC ID: BCG-B35                                                                                                              IC: 579C-B35

                                                      RADIATED EMISSIONS
Marker   Frequency    Meter     Det     AF     Amp/Cbl/Fltr/Pad   DC Corr   Corrected     Avg      Margin     Peak       PK     Azimuth   Height   Polarity
           (GHz)     Reading           T711         (dB)           (dB)      Reading      Limit     (dB)      Limit    Margin    (Degs)    (cm)
                     (dBuV)           (dB/m)                                (dBuV/m)    (dBuV/m)            (dBuV/m)    (dB)
  1        2.503     45.41     PK2    32.4         -20.7             0       57.11         -          -        -          -      139      101        V
  2       * 4.827    37.8      PK2    33.9         -26.9             0       44.8          -          -       74        -29.2     50      272        H
           * 4.83    26.53     MAv1   33.9         -26.9           1.63      35.16        54       -18.84      -          -       50      272        H
  3       * 7.732    36.66     PK2    35.6         -24.8             0       47.46         -          -       74       -26.54     78      254        H
          * 7.729     25       MAv1   35.6         -24.9           1.63      37.33        54       -16.67      -          -       78      254        H
  4      * 11.289    34.64     PK2     38          -21.1             0       51.54         -          -       74       -22.46     64      387        H
         * 11.287    22.99     MAv1    38          -21.1           1.63      41.52        54       -12.48      -          -       64      387        H
  5        * 4.88    38.68     PK2    33.9         -27.4             0       45.18         -          -       74       -28.82     83      109        V
           * 4.88    28.02     MAv1   33.9         -27.4           1.63      36.15        54       -17.85      -          -       83      109        V
  6        * 7.32    39.28     PK2    35.6         -25.9             0       48.98         -          -       74       -25.02    177      182        V
           * 7.32    28.11     MAv1   35.6         -25.9           1.63      39.44        54       -14.56      -          -      177      182        V


 * - indicates frequency in CFR47 Pt 15 / IC RSS-Restricted Band
 PK2 - KDB558074 Method: Maximum Peak
 MAv1 - KDB558074 Option 1 Maximum RMS Average




                                            Page 35 of 45
 UL VERIFICATION SERVICES INC.
 47173 Benicia Street, Fremont, CA 94538; USA           TEL:(510) 771-1000                                              FAX:(510) 661-0888
 This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc.


REPORT NO: 122589553-E1V2                                                                            DATE: 10/30/2018
FCC ID: BCG-B35                                                                                         IC: 579C-B35
                                         HIGH CHANNEL RESULTS




                                                  HORIZTONAL




                                                     VERTICAL




                                           Page 36 of 45
UL VERIFICATION SERVICES INC.
47173 Benicia Street, Fremont, CA 94538; USA           TEL:(510) 771-1000                          FAX:(510) 661-0888
This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc.


 REPORT NO: 122589553-E1V2                                                                                            DATE: 10/30/2018
 FCC ID: BCG-B35                                                                                                         IC: 579C-B35

                                                 RADIATED EMISSIONS
Marker   Frequency    Meter    Det   AF T711   Amp/Cbl/Flt   DC Corr   Corrected   Avg Limit   Margin   Peak Limit     PK Margin   Azimut   Heigh   Polarit
           (GHz)     Readin           (dB/m)    r/Pad (dB)    (dB)      Reading    (dBuV/m)     (dB)    (dBuV/m)         (dB)         h       t       y
                        g                                              (dBuV/m)                                                    (Degs)   (cm)
                     (dBuV)
  1        2.44      47.81    PK2     32.4       -20.6          0       59.61         -           -         -              -       221      124       H
  2       2.502      47.56    PK2     32.4       -20.7          0       59.26         -           -         -              -       216      130       H
  3        2.44      50.43    PK2     32.4       -20.6          0       62.23         -           -         -              -       226      110       V
  4       2.503      48.82    PK2     32.4       -20.7          0       60.52         -           -         -              -       239      101       V
  5       2.469      50.08    PK2     32.4       -20.6          0       61.88         -           -         -              -       229      120       V
  6       * 4.96     41.01    PK2     33.9       -28.2          0       46.71         -           -        74           -27.29     270      211       V
          * 4.96     30.19    MAv1    33.9       -28.2        1.63      37.52        54        -16.48       -              -       270      211       V
  7      * 7.441     38.42    PK2     35.6       -25.1          0       48.92         -           -        74           -25.08      3       329       V
          * 7.44     27.95    MAv1    35.6       -25.1        1.63      40.08        54        -13.92       -              -        3       329       V


 * - indicates frequency in CFR47 Pt 15 / IC RSS-Restricted Band
 PK2 - KDB558074 Method: Maximum Peak
 MAv1 - KDB558074 Option 1 Maximum RMS Average




                                            Page 37 of 45
 UL VERIFICATION SERVICES INC.
 47173 Benicia Street, Fremont, CA 94538; USA           TEL:(510) 771-1000                                           FAX:(510) 661-0888
 This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc.


REPORT NO: 122589553-E1V2                                                                            DATE: 10/30/2018
FCC ID: BCG-B35                                                                                         IC: 579C-B35

    9.3.          WORST CASE BELOW 1 GHz
SPURIOUS EMISSIONS 30 TO 1000 MHz (WORST-CASE CONFIGURATION)




                                                  HORIZTONAL




                                                     VERTICAL


                                           Page 38 of 45
UL VERIFICATION SERVICES INC.
47173 Benicia Street, Fremont, CA 94538; USA           TEL:(510) 771-1000                          FAX:(510) 661-0888
This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc.


REPORT NO: 122589553-E1V2                                                                                                DATE: 10/30/2018
FCC ID: BCG-B35                                                                                                             IC: 579C-B35
Below 1GHz Data
Marker   Frequency     Meter    Det   AF T408   Amp/Cbl (dB)   DC Corr (dB)   Corrected   QPk Limit   Margin   Azimuth     Height   Polarity
           (MHz)      Reading          (dB/m)                                  Reading    (dBuV/m)     (dB)     (Degs)      (cm)
                      (dBuV)                                                  (dBuV/m)
  1        50.8729    33.42     Pk     11.4        -31.7            0          13.12        40        -26.88   0-360        299        H
  2      * 125.4797   38.63     Pk     17.7         -31             0          25.33       43.52      -18.19   0-360        199        H
  4        31.1903    34.53     Pk     24.6        -31.9            0          27.23        40        -12.77   0-360        100        V
  5        79.9929    31.17     Pk     11.5        -31.4            0          11.27        40        -28.73   0-360        100        V
  3       489.8377    31.28     Pk     21.6        -29.1            0          23.78       46.02      -22.24   0-360        299        H
  6       290.9118    31.42     Pk     17.3         -30             0          18.72       46.02       -27.3   0-360        199        V


* - indicates frequency in CFR47 Pt 15 / IC RSS-Restricted Band
Pk - Peak detector




                                           Page 39 of 45
UL VERIFICATION SERVICES INC.
47173 Benicia Street, Fremont, CA 94538; USA           TEL:(510) 771-1000                                         FAX:(510) 661-0888
This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc.


REPORT NO: 122589553-E1V2                                                                            DATE: 10/30/2018
FCC ID: BCG-B35                                                                                         IC: 579C-B35
    9.4.          WORST CASE ABOVE 18-26 GHz
SPURIOUS EMISSIONS 18-26 GHz (WORST-CASE CONFIGURATION)




                                                  HORIZTONAL




                                                     VERTICAL



                                           Page 40 of 45
UL VERIFICATION SERVICES INC.
47173 Benicia Street, Fremont, CA 94538; USA           TEL:(510) 771-1000                          FAX:(510) 661-0888
This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc.


REPORT NO: 122589553-E1V2                                                                                   DATE: 10/30/2018
FCC ID: BCG-B35                                                                                                IC: 579C-B35
18 – 26GHz DATA
Marker   Frequency    Meter    Det   T89 AF   Amp/Cbl (dB)   Dist Corr   Corrected    Avg Limit   Margin    Peak Limit     PK
           (GHz)     Reading         (dB/m)                    (dB)       Reading     (dBuV/m)     (dB)     (dBuV/m)     Margin
                     (dBuV)                                              (dBuVolts)                                       (dB)
  1       20.076     37.53     Pk    32.9         -25          -9.5        35.93         54       -18.07       74        -38.07
  2        21.9      37.34     Pk    33.3        -25.3         -9.5        35.84         54       -18.16       74        -38.16
  3       23.715      38.3     Pk    33.7        -24.2         -9.5         38.3         54        -15.7       74         -35.7
  4       20.789     37.78     Pk    32.7        -24.9         -9.5        36.08         54       -17.92       74        -37.92
  5       22.652     39.28     Pk    33.3         -25          -9.5        38.08         54       -15.92       74        -35.92
  6       23.049     38.33     Pk    33.6        -25.2         -9.5        37.23         54       -16.77       74        -36.77

Pk - Peak detector




                                           Page 41 of 45
UL VERIFICATION SERVICES INC.
47173 Benicia Street, Fremont, CA 94538; USA           TEL:(510) 771-1000                                  FAX:(510) 661-0888
This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc.


REPORT NO: 122589553-E1V2                                                                            DATE: 10/30/2018
FCC ID: BCG-B35                                                                                         IC: 579C-B35
10.      AC POWER LINE CONDUCTED EMISSIONS
LIMITS

FCC §15.207 (a)

RSS-Gen 8.8




TEST PROCEDURE

The EUT is placed on a non-conducting table 40 cm from the vertical ground plane and 80 cm
above the horizontal ground plane. The EUT is configured in accordance with ANSI C63.10.

The receiver is set to a resolution bandwidth of 9 kHz. Peak detection is used unless otherwise
noted as quasi-peak or average.

Line conducted data is recorded for both NEUTRAL and HOT lines.


RESULTS




                                           Page 42 of 45
UL VERIFICATION SERVICES INC.
47173 Benicia Street, Fremont, CA 94538; USA           TEL:(510) 771-1000                          FAX:(510) 661-0888
This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc.


REPORT NO: 122589553-E1V2                                                                            DATE: 10/30/2018
FCC ID: BCG-B35                                                                                         IC: 579C-B35

                                                LINE 1 RESULTS




 Range 1: Line-L1 .15 - 30MHz
Marker   Frequency    Meter    Det   LISN L1     LC        Limiter   Corrected   CFR 47      QP       CFR 47    Av(CISPR
           (MHz)     Reading                    Cables      (dB)     Reading     Part 15   Margin     Part 15    )Margin
                     (dBuV)                     C1&C3                 dBuV       Class B    (dB)      Class B      (dB)
                                                                                   QP                   Avg
  1       .73725      4.32     Qp        0         0        10.1      14.42        56      -41.58        -             -
  2       .73725      3.55     Ca        0         0        10.1      13.65         -         -         46          -32.35
  3       1.7205      4.73     Qp        0        .1        10.1      14.93        56      -41.07        -             -
  4       1.7205      4.05     Ca        0        .1        10.1      14.25         -         -         46          -31.75
  5       2.70375       1.2    Qp        0        .1        10.1      11.4         56       -44.6        -             -
  6       2.70375      -.05    Ca        0        .1        10.1      10.15         -         -         46          -35.85
  7       3.19425       -.7    Qp        0        .1        10.1       9.5         56       -46.5        -             -
  8       3.19425     -2.47    Ca        0        .1        10.1      7.73          -         -         46          -38.27
  9       4.1775      -1.82    Qp        0        .1        10.1      8.38         56      -47.62        -             -
 10       4.1775      -3.67    Ca        0        .1        10.1      6.53          -         -         46          -39.47
 11      25.87875     5.81     Qp       .1        .3        10.5      16.71        60      -43.29        -             -
 12       25.881      4.89     Ca       .1        .3        10.5      15.79         -         -         50          -34.21


Qp - Quasi-Peak detector
Ca - CISPR average detection




                                           Page 43 of 45
UL VERIFICATION SERVICES INC.
47173 Benicia Street, Fremont, CA 94538; USA           TEL:(510) 771-1000                           FAX:(510) 661-0888
This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc.


REPORT NO: 122589553-E1V2                                                                            DATE: 10/30/2018
FCC ID: BCG-B35                                                                                         IC: 579C-B35
                                                LINE 2 RESULTS




 Range 2: Line-L2 .15 - 30MHz
Marker   Frequency    Meter    Det   LISN L2     LC        Limiter   Corrected   CFR 47      QP       CFR 47    Av(CISPR
           (MHz)     Reading                    Cables      (dB)     Reading     Part 15   Margin     Part 15    )Margin
                     (dBuV)                     C2&C3                 dBuV       Class B    (dB)      Class B      (dB)
                                                                                   QP                   Avg
 13       .73725      5.43     Qp        0         0        10.1      15.53        56      -40.47        -             -
 14       .73725      4.87     Ca        0         0        10.1      14.97         -         -         46          -31.03
 15       1.7205      5.99     Qp        0        .1        10.1      16.19        56      -39.81        -             -
 16       1.7205      5.36     Ca        0        .1        10.1      15.56         -         -         46          -30.44
 17       2.70375     2.12     Qp        0        .1        10.1      12.32        56      -43.68        -             -
 18       2.70375       1      Ca        0        .1        10.1      11.2          -         -         46           -34.8
 19       3.19425      .33     Qp        0        .1        10.1      10.53        56      -45.47        -             -
 20       3.19425     -1.52    Ca        0        .1        10.1      8.68          -         -         46          -37.32
 21       4.1775      -1.14    Qp        0        .1        10.1      9.06         56      -46.94        -             -
 22       4.1775      -2.95    Ca        0        .1        10.1      7.25          -         -         46          -38.75
 23      26.49075     3.77     Qp       .1        .3        10.5      14.67        60      -45.33        -             -
 24      26.49075     2.52     Ca       .1        .3        10.5      13.42         -         -         50          -36.58


Qp - Quasi-Peak detector
Ca - CISPR average detection

                                               END OF REPORT




                                           Page 44 of 45
UL VERIFICATION SERVICES INC.
47173 Benicia Street, Fremont, CA 94538; USA           TEL:(510) 771-1000                           FAX:(510) 661-0888
This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc.


REPORT NO: 122589553-E1V2                                                                            DATE: 10/30/2018
FCC ID: BCG-B35                                                                                         IC: 579C-B35
11.      SETUP PHOTOS
Please refer to 12289553-EP1V1 for setup photo




                                           Page 45 of 45
UL VERIFICATION SERVICES INC.
47173 Benicia Street, Fremont, CA 94538; USA           TEL:(510) 771-1000                          FAX:(510) 661-0888
This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc.



Document Created: 2019-03-21 07:30:25
Document Modified: 2019-03-21 07:30:25

© 2024 FCC.report