12458150-S2V1 FCC Report SAR

FCC ID: BCG-A2032

RF Exposure Info

Download: PDF
FCCID_4204549

SAR EVALUATION REPORT



      IEEE Std 1528-2013

           For
    BLUETOOTH EARBUD

      FCC ID: BCG-A2032
      Model Name: A2032



 Report Number: 12458150-S2V1
     Issue Date: 3/15/2019

          Prepared for
          APPLE INC.
   1 INFINITE LOOP, MS 26A
  CUPERTINO, CA 95014-2084

          Prepared by
UL VERIFICATION SERVICES INC.
    47173 BENICIA STREET
  FREMONT, CA 94538, U.S.A.
      TEL: (510) 771-1000
      FAX: (510) 661-0888




      NVLAP LAB CODE 200065-0


Report No.: 12458150-S2V1                                                                        Issue Date: 3/15/2019

REVISION HISTORY
 Rev.    Date             Revisions                                                        Revised By
 V1      3/15/2019        Initial Issue                                                    --




                                                    Page 2 of 16
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 12458150-S2V1                                                                                                        Issue Date: 3/15/2019

                                                                 Table of Contents

1.          Attestation of Test Results ......................................................................................................... 4

2.          Test Specification, Methods and Procedures............................................................................ 5

3.          Facilities and Accreditation ........................................................................................................ 5

4.          SAR Measurement System & Test Equipment .......................................................................... 6
     4.1.      SAR Measurement System ........................................................................................................ 6
     4.2.      SAR Scan Procedures ............................................................................................................... 7
     4.3.      Test Equipment.......................................................................................................................... 9

5.          Measurement Uncertainty ........................................................................................................... 9

6.          Device Under Test (DUT) Information ...................................................................................... 10
     6.1.      DUT Description ...................................................................................................................... 10
     6.2.      Wireless Technologies ............................................................................................................. 10
     6.3.      Maximum Output Power from Tune-up Procedure ................................................................... 10

7.          RF Exposure Conditions (Test Configurations) ...................................................................... 10

8.          Dielectric Property Measurements & System Check .............................................................. 11
     8.1.      Dielectric Property Measurements ........................................................................................... 11
     8.2.      System Check.......................................................................................................................... 12

9.          Conducted Output Power Measurements................................................................................ 13
     9.1.      Bluetooth ................................................................................................................................. 13

10.         Measured and Reported (Scaled) SAR Results ....................................................................... 14
     10.1.        Bluetooth .............................................................................................................................. 14

11.         SAR Measurement Variability ................................................................................................... 14

12.         Simultaneous Transmission SAR Analysis ............................................................................. 15

Appendixes .......................................................................................................................................... 16
     Appendix A: SAR Setup Photos ......................................................................................................... 16
     Appendix B: SAR System Check Plots ............................................................................................... 16
     Appendix C: SAR Highest Test Plots .................................................................................................. 16
     Appendix D: SAR Tissue Ingredients.................................................................................................. 16
     Appendix E: SAR Probe Certificates................................................................................................... 16
     Appendix F: SAR Dipole Certificates .................................................................................................. 16




                                                    Page 3 of 16
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 12458150-S2V1                                                                         Issue Date: 3/15/2019

1. Attestation of Test Results
Applicant Name                     APPLE INC.
FCC ID                             BCG-A2032
Model Name                         A2032
Exposure Category                  General Population/Uncontrolled Exposure
Applicable Standards               FCC 47 CFR § 2.1093
                                   Published RF exposure KDB procedures
                                   IEEE Std 1528-2013
                                                                   SAR Limits (W/Kg)
Exposure Category                  Peak spatial-average(1g of tissue)        Extremities (hands, wrists, ankles, etc.)
                                                                             (10g of tissue)
General                            1.6                                       4
population/Uncontrolled
exposure
                                                   Equipment Class - Highest Reported SAR (W/kg)
RF Exposure Conditions
                                           PCE                 DTS                   NII                  DSS
Head                                       N/A                 N/A                   N/A                 0.581
Date Tested                        3/15/2019 to 3/15/2019
Test Results                       Pass
 UL Verification Services Inc. tested the above equipment in accordance with the requirements set forth in the
 above standards. All indications of Pass/Fail in this report are opinions expressed by UL Verification Services Inc.
 based on interpretations and/or observations of test results. Measurement Uncertainties were not taken into
 account and are published for informational purposes only. The test results show that the equipment tested is
 capable of demonstrating compliance with the requirements as documented in this report.
Note: The results documented in this report apply only to the tested sample, under the conditions and modes of
operation as described herein. This document may not be altered or revised in any way unless done so by UL
Verification Services Inc. and all revisions are duly noted in the revisions section. Any alteration of this document
not carried out by UL Verification Services Inc. will constitute fraud and shall nullify the document. This report
must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, any
agency of the Federal Government, or any agency of any government (NIST Handbook 150, Annex A). This report
is written to support regulatory compliance of the applicable standards stated above.
Approved & Released By:                                     Prepared By:




Devin Chang                                                 Florencio Pesigan
Senior Test Engineer                                        Laboratory Technician
UL Verification Services Inc.                               UL Verification Services Inc.




                                                    Page 4 of 16
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 12458150-S2V1                                                                        Issue Date: 3/15/2019

2. Test Specification, Methods and Procedures
The tests documented in this report were performed in accordance with FCC 47 CFR § 2.1093, IEEE STD 1528-
2013, the following FCC Published RF exposure KDB procedures:
   o 447498 D01 General RF Exposure Guidance v06
   o 447498 D03 Supplement C Cross-Reference v01
   o 865664 D01 SAR measurement 100 MHz to 6 GHz v01r04
   o 865664 D02 RF Exposure Reporting v01r02

In addition to the above, the following information was used:
    o   TCB workshop October 2016; RF Exposure Procedures (Bluetooth Duty Factor)
    o   TCB workshop October 2016; RF Exposure Procedures (DUT Holder Perturbations)



3. Facilities and Accreditation
The test sites and measurement facilities used to collect data are located at

             47173 Benicia Street                             47266 Benicia Street
                  SAR Lab A                                        SAR Lab 1
                  SAR Lab B                                        SAR Lab 2
                  SAR Lab C                                        SAR Lab 3
                  SAR Lab D                                        SAR Lab 4
                  SAR Lab E                                        SAR Lab 5
                  SAR Lab F
                  SAR Lab G
                  SAR Lab H
UL Verification Services Inc. is accredited by NVLAP, Laboratory Code 200065-0.




                                                    Page 5 of 16
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 12458150-S2V1                                                                         Issue Date: 3/15/2019

4. SAR Measurement System & Test Equipment
4.1.    SAR Measurement System
The DASY5 system used for performing compliance tests consists of the following items:




   A standard high precision 6-axis robot with controller, teach pendant and software. An arm extension for
    accommodating the data acquisition electronics (DAE).
   An isotropic Field probe optimized and calibrated for the targeted measurement.
   A data acquisition electronics (DAE) which performs the signal amplification, signal multiplexing, AD-
    conversion, offset measurements, mechanical surface detection, collision detection, etc. The unit is battery
    powered with standard or rechargeable batteries. The signal is optically transmitted to the EOC.
   The Electro-optical converter (EOC) performs the conversion from optical to electrical signals for the digital
    communication to the DAE. To use optical surface detection, a special version of the EOC is required. The
    EOC signal is transmitted to the measurement server.
   The function of the measurement server is to perform the time critical tasks such as signal filtering, control of
    the robot operation and fast movement interrupts.
   The Light Beam used is for probe alignment. This improves the (absolute) accuracy of the probe positioning.
   A computer running WinXP or Win7 and the DASY5 software.
   Remote control and teach pendant as well as additional circuitry for robot safety such as warning lamps, etc.
   The phantom, the device holder and other accessories according to the targeted measurement.




                                                    Page 6 of 16
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 12458150-S2V1                                                                        Issue Date: 3/15/2019

4.2. SAR Scan Procedures
Step 1: Power Reference Measurement
The Power Reference Measurement and Power Drift Measurements are for monitoring the power drift of the device
under test in the batch process. The minimum distance of probe sensors to surface determines the closest
measurement point to phantom surface. The minimum distance of probe sensors to surface is 2.1 mm. This
distance cannot be smaller than the distance of sensor calibration points to probe tip as defined in the probe
properties.

Step 2: Area Scan
The Area Scan is used as a fast scan in two dimensions to find the area of high field values, before doing a fine
measurement around the hot spot. The sophisticated interpolation routines implemented in DASY software can find
the maximum locations even in relatively coarse grids. When an Area Scan has measured all reachable points, it
computes the field maximal found in the scanned area, within a range of the global maximum. The range (in dB) is
specified in the standards for compliance testing. For example, a 2 dB range is required in IEEE Standard 1528
and IEC 62209 standards, whereby 3 dB is a requirement when compliance is assessed in accordance with the
ARIB standard (Japan). If only one Zoom Scan follows the Area Scan, then only the absolute maximum will be
taken as reference. For cases where multiple maximums are detected, the number of Zoom Scans has to be
increased accordingly.
Area Scan Parameters extracted from KDB 865664 D01 SAR Measurement 100 MHz to 6 GHz




                                                    Page 7 of 16
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 12458150-S2V1                                                                        Issue Date: 3/15/2019
Step 3: Zoom Scan
Zoom Scans are used to assess the peak spatial SAR values within a cubic averaging volume containing 1 g and
10 g of simulated tissue. The Zoom Scan measures points (refer to table below) within a cube whose base faces
are centered on the maxima found in a preceding area scan job within the same procedure. When the
measurement is done, the Zoom Scan evaluates the averaged SAR for 1 g and 10 g and displays these values
next to the job’s label.
Zoom Scan Parameters extracted from KDB 865664 D01 SAR Measurement 100 MHz to 6 GHz




Step 4: Power drift measurement
The Power Drift Measurement measures the field at the same location as the most recent power reference
measurement within the same procedure, and with the same settings. The Power Drift Measurement gives the field
difference in dB from the reading conducted within the last Power Reference Measurement. This allows a user to
monitor the power drift of the device under test within a batch process. The measurement procedure is the same as
Step 1.




                                                    Page 8 of 16
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 12458150-S2V1                                                                                     Issue Date: 3/15/2019


4.3. Test Equipment
The measuring equipment used to perform the tests documented in this report has been calibrated in accordance
with the manufacturers’ recommendations, and is traceable to recognized national standards.
Dielectric Property Measurements
Name of Equipment                                  Manufacturer                 Type/Model       Serial No.         Cal. Due Date
Network Analyzer                                        R&S                       ZNLE6         PRE0181650           7/16/2019
Dielectric Probe kit                                  SPEAG                      DAK-3.5            1082             9/11/2019
Shorting block                                        SPEAG                    DAK-3.5 Short   SM DAK 200 DA         9/11/2019
Thermometer                                Traceable Calibration Control Co.   15-1078-179       150378159            6/6/2019
System Check
Name of Equipment                                 Manufacturer                 Type/Model        Serial No.        Cal. Due Date
Signal Generator                               Rhode & Schwarz                  SMB100A         180970-zC            2/13/2020
Power Sensor                                   Rhode & Schwarz                   NRP18A         100994-RE            2/15/2020
Lab Equipment
Name of Equipment                                 Manufacturer                  Type/Model       Serial No.        Cal. Due Date
E-Field Probe (SAR Lab 2)                             SPEAG                      EX3DV4            3686              8/28/2019
E-Field Probe (SAR Lab 4)                             SPEAG                      EX3DV4            7356              4/24/2019
Data Acquisition Electronics (SAR Lab 2)              SPEAG                       DAE4             1545              4/13/2019
Data Acquisition Electronics (SAR Lab 4)              SPEAG                       DAE4             1547               5/3/2019
System Validation Dipole                              SPEAG                      D2450V2            706              5/18/2019
Thermometer                                        Fisherbrand                 281 482-1714     181062309            2/21/2020
Other
Name of Equipment                                 Manufacturer                 Type/Model        Serial No.        Cal. Due Date
Power Meter                                           Agilent                    N1912A        MY55196015            1/29/2020
Power Sensor                                          Agilent                    N1921A        MY52270022            2/6/2020




5. Measurement Uncertainty
Per KDB 865664 D01 SAR Measurement 100 MHz to 6 GHz, when the highest measured 1-g SAR within a
frequency band is < 1.5 W/kg and the measured 10-g SAR within a frequency band is < 3.75 W/kg. The expanded
SAR measurement uncertainty must be ≤ 30%, for a confidence interval of k = 2. If these conditions are met,
extensive SAR measurement uncertainty analysis described in IEEE Std 1528-2013 is not required in SAR reports
submitted for equipment approval.
Therefore, the measurement uncertainty is not required.




                                                    Page 9 of 16
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 12458150-S2V1                                                                                    Issue Date: 3/15/2019

6. Device Under Test (DUT) Information
6.1.     DUT Description
 A2032 is a Bluetooth earbud for the right ear. It has an integral battery, microphone and antenna. It can charge
 via bottom contacts and with charge case. It is designed to work in conjunction with left earbud, A2031.
                               Overall (Length x Width x Height): 16.5 mm x 18 mm x 40.5 mm
 Device Dimension
                               This is a Small device (When the factor is smaller than 9 cm × 5 cm)
 Battery Options               The rechargeable battery is not user accessible.


6.2.     Wireless Technologies
     Wireless                                                                                                Duty Cycle used for SAR
                         Frequency bands                                   Operating mode
   technologies                                                                                                      testing
 Bluetooth           2.4 GHz                          Version 5.0 LE                                         100% (DH5)



6.3.     Maximum Output Power from Tune-up Procedure
KDB 447498 sec.4.1.(3) at the maximum rated output power and within the tune-up tolerance range specified for
the product, but not more than 2 dB lower than the maximum tune-up tolerance limit

                                                                        Max. RF Output
                    RF Air interface
                                                                         Pow er (dBm)
                       Bluetooth                                            12.50
                    Bluetooth EDR                                                 10.00
                     Bluetooth LE                                                 10.00



7. RF Exposure Conditions (Test Configurations)
Refer to Appendix A for the specific details of the antenna-to-antenna and antenna-to-edge(s) distances.
     Wireless           RF Exposure              DUT-to-User               Test                Antenna-to-      SAR
                                                                                                                            Note
   technologies          Conditions               Separation              Position            edge/surface    Required
                           Head                                         Right Touch            < 25mm           Yes
     Bluetooth                                      0 mm
                           Body                                          Right Flat            < 25mm           Yes




                                                   Page 10 of 16
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 12458150-S2V1                                                                                            Issue Date: 3/15/2019

8. Dielectric Property Measurements & System Check
8.1.    Dielectric Property Measurements
The temperature of the tissue-equivalent medium used during measurement must also be within 18C to 25C and
within ± 2C of the temperature when the tissue parameters are characterized.
The dielectric parameters must be measured before the tissue-equivalent medium is used in a series of SAR
measurements. The parameters should be re-measured after each 3 – 4 days of use; or earlier if the dielectric
parameters can become out of tolerance; for example, when the parameters are marginal at the beginning of the
measurement series.
Tissue dielectric parameters were measured at the low, middle and high frequency of each operating frequency
range of the test device.
The dielectric constant (εr) and conductivity (σ) of typical tissue-equivalent media recipes are expected to
be within ± 5% of the required target values; but for SAR measurement systems that have implemented the SAR
error compensation algorithms documented in IEEE Std 1528-2013, to automatically compensate the measured
SAR results for deviations between the measured and required tissue dielectric parameters, the tolerance for εr and
σ may be relaxed to ± 10%. This is limited to frequencies ≤ 3 GHz.

Tissue Dielectric Parameters
FCC KDB 865664 D01 SAR Measurement 100 MHz to 6 GHz
                                                Head                                                   Body
    Target Frequency (MHz)
                                      er                  s (S/m)                         er                           s (S/m)
             150                     52.3                  0.76                          61.9                           0.80
             300                     45.3                  0.87                          58.2                           0.92
             450                     43.5                  0.87                          56.7                           0.94
             835                     41.5                  0.90                          55.2                           0.97
             900                     41.5                  0.97                          55.0                           1.05
             915                     41.5                  0.98                          55.0                           1.06
            1450                     40.5                  1.20                          54.0                           1.30
            1610                     40.3                  1.29                          53.8                           1.40
         1800 – 2000                 40.0                  1.40                          53.3                           1.52
            2450                     39.2                  1.80                          52.7                           1.95
            3000                     38.5                  2.40                          52.0                           2.73
            5000                     36.2                  4.45                          49.3                           5.07
            5100                     36.1                  4.55                          49.1                           5.18
            5200                     36.0                  4.66                          49.0                           5.30
            5300                     35.9                  4.76                          48.9                           5.42
            5400                     35.8                  4.86                          48.7                           5.53
            5500                     35.6                  4.96                          48.6                           5.65
            5600                     35.5                  5.07                          48.5                           5.77
            5700                     35.4                  5.17                          48.3                           5.88
            5800                     35.3                  5.27                          48.2                           6.00

IEEE Std 1528-2013
Refer to Table 3 within the IEEE Std 1528-2013


Dielectric Property Measurements Results:
  SAR                   Band        Tissue       Frequency       Relative Perm ittivity (єr)                   Conductivity (σ)
            Date                                                                          D e lt a                                  D e lt a
  Lab                  (MHz)         Type          (MHz)     M e a s ure d   T a rge t               M e a s ure d      T a rge t
                                                                                          ±5 %                                      ±5 %
                                                   2450         51.65         52.70       -1.99         2.04             1.95        4.51
   2      3/15/2019     2450         Body          2400         51.77         52.77       -1.90         1.98             1.90        4.16
                                                   2480         51.59         52.66       -2.04         2.07             1.99        3.86
                                                   2450         37.78         39.20       -3.62         1.81             1.80        0.50
   4      3/15/2019     2450         Head          2400         37.82         39.30       -3.76         1.77             1.75        1.05
                                                   2480         37.77         39.16       -3.55         1.83             1.83       -0.24




                                                   Page 11 of 16
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 12458150-S2V1                                                                                                                                         Issue Date: 3/15/2019

8.2.         System Check
SAR system verification is required to confirm measurement accuracy, according to the tissue dielectric media,
probe calibration points and other system operating parameters required for measuring the SAR of a test device.
The system verification must be performed for each frequency band and within the valid range of each probe
calibration point required for testing the device. The same SAR probe(s) and tissue-equivalent media combinations
used with each specific SAR system for system verification must be used for device testing. When multiple probe
calibration points are required to cover substantially large transmission bands, independent system verifications are
required for each probe calibration point. A system verification must be performed before each series of SAR
measurements using the same probe calibration point and tissue-equivalent medium. Additional system verification
should be considered according to the conditions of the tissue-equivalent medium and measured tissue dielectric
parameters, typically every three to four days when the liquid parameters are re-measured or sooner when
marginal liquid parameters are used at the beginning of a series of measurements.

System Performance Check Measurement Conditions:
        The measurements were performed in the flat section of the TWIN SAM or ELI phantom, shell thickness: 2.0
         ±0.2 mm (bottom plate) filled with Body or Head simulating liquid of the following parameters.
        The depth of tissue-equivalent liquid in a phantom must be ≥ 15.0 cm for SAR measurements ≤ 3 GHz and ≥
         10.0 cm for measurements > 3 GHz.
        The DASY system with an E-Field Probe was used for the measurements.
        The dipole was mounted on the small tripod so that the dipole feed point was positioned below the center
         marking of the flat phantom section and the dipole was oriented parallel to the body axis (the long side of the
         phantom). The standard measuring distance was 10 mm (above 1 GHz) and 15 mm (below 1 GHz) from dipole
         center to the simulating liquid surface.
        The coarse grid with a grid spacing of 15 mm was aligned with the dipole.
         For 5 GHz band - The coarse grid with a grid spacing of 10 mm was aligned with the dipole.
        Special 7x7x7 (below 3 GHz) and/or 8x8x7 (above 3 GHz) fine cube was chosen for the cube.
        Distance between probe sensors and phantom surface was set to 3 mm.
         For 5 GHz band - Distance between probe sensors and phantom surface was set to 2.5 mm
        The dipole input power (forward power) was 100 mW.
        The results are normalized to 1 W input power.

System Check Results
The 1-g and 10-g SAR measured with a reference dipole, using the required tissue-equivalent medium at the test
frequency, must be within ±10% of the manufacturer calibrated dipole SAR target. Refer to Appendix B for the
SAR System Check Plots.

                                                                                 Measured Results for 1g SAR                                  Measured Results for 10g SAR
    SAR                 Tissue                             Dipole                                                                                                                                   P lo t
              Date               Dipole Type_Serial #                                                                                                                                               No.
    Lab                  Type                           Cal. Due Data   Z o o m Scan    N o rm a lize      Target             Delta   Z o o m Scan    N o rm a lize      Target             Delta
                                                                         t o 10 0 m W      to 1 W       ( R e f . V a lue )   ±10 %    t o 10 0 m W      to 1 W       ( R e f . V a lue )   ±10 %


     2      3/15/2019    Body      D2450V2 SN:706         5/18/2019        5.400           54.00             50.60            6.72       2.440           24.40             23.70            2.95     1,2

     4      3/15/2019    Head      D2450V2 SN:706         5/18/2019        5.370           53.70             52.60            2.09       2.490           24.90             24.60            1.22     3,4




                                                   Page 12 of 16
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 12458150-S2V1                                                                        Issue Date: 3/15/2019

9. Conducted Output Power Measurements
9.1.    Bluetooth
Bluetooth Measured Results
From October 2016 TCB workshop, this device power and SAR measured is performed with test
software, the duty cycle is 100%.
SAR measurement is not required for the QPSK, 8PSK, and BLE. When the secondary mode is ≤ ¼ dB higher than
the primary mode.
                                                         Average Pow er (dBm )
                                          Freq.
    Band        Mode         Ch #                                           SAR Test
                                         (MHz)     Meas Pw r    Tune-up
                                                                            (Yes/No)
                              0          2402        12.50        12.50
  2.4 GHz       GFSK          39         2441        12.50        12.50        Yes
                              78         2480        12.50        12.50

                                                Duty Cycle plots
                                                        GFSK




                                                   Page 13 of 16
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 12458150-S2V1                                                                                                                          Issue Date: 3/15/2019

10.             Measured and Reported (Scaled) SAR Results
SAR Test Reduction criteria are as follows:
      Reported SAR(W/kg) for WWAN = Measured SAR *Tune-up Scaling Factor
      Reported SAR(W/kg) for Wi-Fi and Bluetooth = Measured SAR * Tune-up scaling factor * Duty Cycle scaling factor
      Duty Cycle scaling factor = 1 / Duty cycle (%)

KDB 447498 D01 General RF Exposure Guidance:
Testing of other required channels within the operating mode of a frequency band is not required when the reported 1-g or 10-g
SAR for the mid-band or highest output power channel is:
   ≤ 0.8 W/kg or 2.0 W/kg, for 1-g or 10-g respectively, when the transmission band is ≤ 100 MHz
   ≤ 0.6 W/kg or 1.5 W/kg, for 1-g or 10-g respectively, when the transmission band is between 100 MHz and 200 MHz
   ≤ 0.4 W/kg or 1.0 W/kg, for 1-g or 10-g respectively, when the transmission band is ≥ 200 MHz

10.1.            Bluetooth
                                                                                                          Power (dBm)         1-g SAR (W/kg)       10-g SAR (W/kg)
    RF Exposure                   Dist.                                     Freq.        Duty                                                                        Plot
                       Mode                Test Position    Ch #.                                   Tune-up
     Conditions                   (mm)                                     (MHz)         Cycle                   Meas.       Meas.        Scaled   Meas.    Scaled   No.
                                                                                                     Limit
        Head                               Right Touch       39            2441          100.0%      12.50       12.50        0.095       0.095     0.045   0.045     1
                      GFSK          0
        Body                                 Right Flat      39            2441          100.0%      12.50       12.50        0.581       0.581     0.169   0.169     2


Notes:
SAR Testing was performed on the Flat Phantom for normal use for Head. Additional SAR Testing was performed on the location clos est to the
Antenna (Rear of the Device) of similar configuration to demonstrate compliance. This was reported as the highest SAR.



11.             SAR Measurement Variability
In accordance with published RF Exposure KDB 865664 D01 SAR measurement 100 MHz to 6 GHz. These
additional measurements are repeated after the completion of all measurements requiring the same head or body
tissue-equivalent medium in a frequency band. The test device should be returned to ambient conditions (normal
room temperature) with the battery fully charged before it is re-mounted on the device holder for the repeated
measurement(s) to minimize any unexpected variations in the repeated results.

1) Repeated measurement is not required when the original highest measured SAR is <0.8 or 2 W/kg (1-g or 10-g
   respectively); steps 2) through 4) do not apply.
2) When the original highest measured SAR is ≥ 0.8 or 2 W/kg (1-g or 10-g respectively), repeat that
   measurement once.
3) Perform a second repeated measurement only if the ratio of largest to smallest SAR for the original and first
   repeated measurements is > 1.20 or 3 (1-g or 10-g respectively) or when the original or repeated measurement
   is ≥ 1.45 or 3.6 W/kg (~ 10% from the 1-g or 10-g respective SAR limit).
4) Perform a third repeated measurement only if the original, first, or second repeated measurement is ≥ 1.5 or
   3.75 W/kg (1-g or 10-g respectively) and the ratio of largest to smallest SAR for the original, first and second
   repeated measurements is > 1.20 or 3 (1-g or 10-g respectively).

                                                                                                                         First
    Frequency                                                                 Repeated         Highest                 Repeated
       Band       Air Interface   RF Exposure Conditions   Test Position        SAR           Measured         Measured      Largest to
      (MHz)                                                                   (Yes/No)       SAR (W/kg)          SAR          Smallest
                                                                                                                (W/kg)       SAR Ratio
      2400            BT                  Body              Right Flat              No            0.581          N/A              N/A



Note(s):
Second Repeated Measurement is not required since the ratio of the largest to smallest SAR for the original and first repeated
measurement is not > 1.20 or 3 (1-g or 10-g respectively).




                                                   Page 14 of 16
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 12458150-S2V1                                                                        Issue Date: 3/15/2019

12.     Simultaneous Transmission SAR Analysis
N/A




                                                   Page 15 of 16
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 12458150-S2V1                                                                        Issue Date: 3/15/2019

Appendixes
Refer to separated files for the following appendixes.

Appendix A: SAR Setup Photos

Appendix B: SAR System Check Plots

Appendix C: SAR Highest Test Plots

Appendix D: SAR Tissue Ingredients

Appendix E: SAR Probe Certificates

Appendix F: SAR Dipole Certificates



                                                END OF REPORT




                                                   Page 16 of 16
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.



Document Created: 2019-03-22 02:16:11
Document Modified: 2019-03-22 02:16:11

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC