Test Report_SAR_Appendix B

FCC ID: B94-AX200D2LZ

RF Exposure Info

Download: PDF
FCCID_4405417

                                                                                                                                                         Report No. : EN/2019/60025
                                                                                                                                                         Rev: 01
                                                                                                                                                         Page: 1                  of   15




                           Appendix B — DAE & Probe Calibration Certificate

                                        Calibration Laboratory of                                                                                 Schweizerischer Kalibrierdienst
                                        Schmid & Partner                                                                                          Service suisse d‘étalonnage
                                          Engineering AG                                                                                          Servizio svizzero di taratura
                                        Zeughausstrasse 43, 8004 Zurich, Switzerland                                                              Swiss Calibration Service

                                        Accredited by the Swiss Accreditation Service (SAS)                                       Accreditation No.; SCS 0108
                                        The Swiss Accreditation Service is one of the signatories to the EA
                                        Multilateral Agreement for the recognition of calibration certificates

                                        Ciient          SGS~ TW (Auden)                                                           Certificate No: DAE4—856_Apr19

                                       [CALIBRATION CERTIFICATE
                                         Object                             DAE4 — SD 000 D04 BM — SN: 856


                                         Callbration procedure(s)           QA CAL—06.v29
                                                                            Calibration procedurefor the data acquisition electronics (DAE)



                                        Galibration date:                   April 24, 2019




                                        This callbration certficate documents the traceabilly to national standards, which realze the physical units of measurements (S1)
                                        The measurements and the uncertainties wih confidence probabiity are given on the folowing pages and aro part of tho cortficate.

                                        All allbrations have been conducted in the closed laboratory facifly; environment temperature (22 + 3)°C and huridty< 70%

                                        Calibration Equipment used (M&TE crtical for caltration)

                                        Primary Standards                   io #                     Cal Date (Gortficate No.)                        Scheduled Calbration
                                        Keithley Mulimeter Type 2001        | sn otozra              03—Sep—18 (No:23488)                             Sep—10

                                        Secondary Standards                 |10 #                    Check Date (in house)                            Scheduled Check
                                        Auto DAE Calibration Unit           | se uws 058 AA 1001 07—Jan—19 (in house check)                           in house check: Jan—20
                                        Calibrator Box V2.1                   SE UMS 006 AA 1002 07—Jan—19 (in house check)                           in house check: Jan—20




                                                                            Name                                 Function                             Signature
                                        Calibrated by:                      Adian Gehring                        Laboratory Techniclan
                                                                                                                                                     A
                                        Approved by:                        Sven Kn                              Depuly Manager
                                                                                                                                                       . C Puuc
                                                                                                                                                      Issued: April 24, 2019
                                        This calibration certficate shall not be reproduced except ifull wihout writen approval of tlaboratory:


                                      Certificate No: DAE4—856_Apr9                                     Page 1 of 5




Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only.
BobSein. meeeieenneiemet > eeviipeiain roor » dieLcAcereirer > rorastite —
This document is issued by the Company subject to its General Conditions of Service printed overleal, available on request or accessible at www.sgs.comferms and conditions.him and for electronic format
documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms e—documenthim, Aftention is drawn to the limitation of labiity, indemnification and jurisdiction issues defined
therein. Any holder of this document is advised that information contained hereon reflects the Company‘s findings at the time of its intervention only and within the limits of Client‘s instructions, if any. The
Company‘s sole responsibilty is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot
be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsifcation of the content or appearanceof this document is unfawful and offenders may be
prosecuted to the fullest extent of the law.
                            SGS Taiwan Ltd.           No.134,Wu Kung Road, New Taipei Industrial Park, Wuku District, New Taipei City, Taiwan 24803/ak ir %.M% 0 #rak & # )(E x i6134
             6 MMoticttBieid PRar s1                  1 (B86—2) 2200.s279                                  1 (Bas—2) 22es—0488                        wwwetw.ags.com
                                                  |                                                                                                   Member of SGS Group


                                                                                                                                                 Report No. : EN/2019/60025
                                                                                                                                                 Rev: 01
                                                                                                                                                 Page: 2               of      15




                                     Calibration
                                           "     Laboratory of
                                                                                                                                          &    Schweizerischer Kalibrierdienst
                                     Schm[d & F_’artner                                                                                   .    Service suisse d‘étalonnage
                                       Engineering AG                                                                                          Servizio svizzero di taratura
                                     Zeughausstrasse 43, 8004 Zurich, Switzerland                                                         S    swiss Calibration Service
                                     Accredited by the Swiss Accreditation Service (SAS)                                                   Acereditation No.: SCS 0108
                                     The Swiss Accreditation Service is one of the signatories to the EA
                                     Mulllateral Agreementfor the recognition of calibration certificates


                                     Glossary
                                     DAE                            data acquisition electronics
                                     Connector angle                information used in DASY system to align probe sensor X to the robot
                                                                    coordinate system.

                                     Methods Applied and Interpretation of Parameters
                                        *  DC Voltage Measurement: Calibration Factor assessed for use in DASY system by
                                          comparison with a calibrated instrumenttraceable to national standards. The figure given
                                          corresponds to the full scale range of the voltmeterin the respective range.
                                          «_       Connector angle: The angle of the connectoris assessed measuring the angle
                                                   mechanically by a toolinserted. Uncertainty is not required.
                                         *     The following parameters as documented in the Appendix contain technical information as a
                                               result from the performance test and require no uncertainty.
                                               *        DC Voltage Measurement Linearity: Verification of the Linearity at +10%and —10% of
                                                        the nominal calibration voltage. Influence of offset voltage is included in this
                                                        measurement.
                                               *        Common mode sensitivity: Influence of a positive or negative common mode voltage on
                                                        the differential measurement.
                                               *        Channel separation: Influence of a voltage on the neighbor channels not subject to an
                                                        input voltage.
                                               *        AD Converter Values with inputs shorted: Values on the internal AD converter
                                                        corresponding to zero input voltage
                                               *        Input Offset Measurement; Output voltage and statistical results over a large number of
                                                        zero voltage measurements.
                                               *        Input Offset Current: Typical value for information; Maximum channel input offset
                                                        current, not considering the input resistance.
                                               *        Input resistance: Typical value for information: DAE input resistance at the connector,
                                                        during internal auto—zeroing and during measurement.
                                               *        Low Battery Alarm Voltage: Typical value for information. Below this voltage, a battery
                                                        alarm signal is generated.
                                               *        Power consumption: Typical value for information. Supply currents in various operating
                                                        modes.




                                   Certificate No: DAE4—856_Apri9                                  Page 2 of 5




Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only.
BohSstee . mineennzse > Reinesier roor + dtencAcermite > moeoiee >
This document is issued by the Company subject to its General Conditions of Service printed overleal, available on request or accessible at www.sgs.comferms and conditions.him and for electronic format
documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms e—documenthim. Attention is drawn to the limitation of labilty, indemnification and jurisdiction J                      e
                                                                                                                                                                                                     issues detined
therein. Any holder of this document is advised that information contained hereon reflects the Company‘s findings at the time of its intervention only and within the limits of Client‘s instructions, if any. The
Company‘s sole responsibilty is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot
be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsifcation of the content or appearanceof this document is unfawful and offenders may be
prosecuted to the fullest extent of the law.
                             SGS Taiwan Ltd.           No.134,Wu Kung Road, New Taipei Industrial Park, Wuku District, New Taipei City, Taiwan 24803/ak ir %.M% 0 #rak & # )(E x i6134
             6 MMoticttBieid PRar s1                   1 (B86—2) 2200.s279                            1 (Bas—2) 22es—0488                     wwwetw.ags.com
                                                   |                                                                                          Member of SGS Group


                                                                                                                                                 Report No. : EN/2019/60025
                                                                                                                                                 Rev: 01
                                                                                                                                                 Page: 3           of      15




                                     DC Voltage Measurement
                                          A/D — Gonverter Resolution nominal
                                              High Range:          1LS8 =               6AuV ,           full range =    —100...+800 mV
                                              Low Range:           1L8SB=               61nV ,           full range =    —1.......+3mV
                                          DASY measurement parameters: Auto Zero Time: 3 sec; Measuring time: 3 see


                                            Calibration Factors                     x                             Y                              2
                                            High Range                 403400 + 0.02% (k=2)          404.514 + 0.02% (k=2)          403.834 £0.02% (k=2)
                                            Low Range                  3.97649 + 1.50%(k=2)          3.98674+1.50% (k=2)            3.94236 + 1.50% (k=2)



                                     Connector Angle

                                          Eonneclor Angle to be used in DASY system                                                       264.5 °+1 °   j




                                   Certificate No: DAE4—856_Apr19                                  Page 3 of 5




Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 80 days only.
BohSstee . mine en nzse > Reinesier roor + d t encA cermite > moeoiee >
This document is issued by the Company subject to its General Conditions of Service printed overleal, available on request or accessible at www.sgs.comferms and conditions.him and for electronic format
documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms e—documenthtm, Attention is drawn to the limitation of labilty, indemnification and jurisdiction issues detined
therein. Any holder of this document is advised that information contained hereon reflects the Company‘s findings at the time of its intervention only and within the fmits of Client‘s instructions, it any. The
Company‘s sole responsibilty is to its Client and this document doss not exonerate paties to a transaction from exercising alltheir rights and obligations under the transaction documents. This document cannot
be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsifcation of the content or appearanceof this document is unlawlul and offenders may be
prosecuted to the fullest extent of the law.
                             SGS Taiwan Ltd.      No.134,Wu Kung Road, New Taipei Industrial Park, Wuku District, New Taipei City, Taiwan 24803/ak ir %.M% 0 #rak & # )(E x i6134
             6MoiliettBiefirdr mm s]             1 (BB6—2) 2200—9270                                  1 (B86—2) 2208—0488                     www.twags.com
                                                                                                                                              Member of SGS Group


                                                                                                                                                 Report No. : EN/2019/60025
                                                                                                                                                 Rev: 01
                                                                                                                                                 Page:          4     of      15




                                    Appendix (Additional assessments outside the scope of SCS0108)

                                    1. DC Voltage Linearity
                                          High Range                                  Reading (V)                Difference (uV)               Error (%)
                                          Channel X           + Input                   199994.07                        0.95                   0.00
                                          Channel X           + Input                    19999.17                       —2.09                  —0.01
                                          Channel X           — Input                   —20000.00                        1.59                  —0.01
                                          Channel Y           + Input                   199993.69                        0.37                   0.00
                                          Channel Y           + Input                    19998.33                       —2.97                  —0.01
                                          Channel Y           — Input                   —20002.50                       —0.88                   0.00
                                          ChannelZ            + Input                   199998.47                       —0.14                  —0.00
                                          ChannelZ            + Input                    19998.83                       —2.35                  —0.01
                                          ChannelZ            — Input                   —20002.52                       —0.77                   0.00


                                          Low Range                                   Reading (xV)               Difference (V)                Error (%)
                                          Channel X           + Input                    2000.95                         0.19                   0.01
                                          Channel X           + Input                     201.39                         0.20                   0.10
                                          ChannelX            — Input                     —198.76                       —0.08                   0.04
                                          ChannelY            + Input                    2000.77                        —0.00                  —0.00
                                          ChannelY            + Input                     200.61                        —0.60                  —0.30
                                          Channel Y           — Input                    —199.00                        —0.38                  0.19
                                          Channel Z           + Input                    2000.74                         0.11                  0.01
                                          Channel Z           + Input                     200.00                        —1.10                  —0.55

                                          Channel Z           — Input                    —200.10                        +1.29                  0.65



                                   2. Common mode sens
                                        DASY measurement parameters: Auto Zero Time: 3 sec; Measuring time: 3 sec

                                                                Common mode                         High Range                              Low Range
                                                                Input Voltage (mV)              Average Reading (1V)                   Average Reading (1V)

                                         Channel X                              200                          ~15.47                         —16.43

                                                                              —200                           17.24                           15.88

                                         Channel Y                              200                          —2.49                           —1.95
                                                                              ~200                            1.02                           0.67

                                         Channel Z                              200                          10.56                           10.55

                                                                              — 200                          —13.14                         —13.28



                                       Channel separation
                                  ®




                                        DASY measurement parameters: Auto Zero Time: 3 sec; Measuring time: 3 se
                                                               Input Voltage (mV)         Channel X (gV)              Channel Y (uV)       Channel Z (@V)

                                         Channel X                      200                         —                      315                  —8.11
                                         Channel Y                      200                      6.52                           —               2.77
                                         ChannelZ                       200                      8.20                      5.20                      —

                                   Certficate No: DAE4—856_Apr19                                        Page 4 of 5




Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only.
Beksberiees . neemesemeaenns 2hmmatr + maieiesntieie Rrooye + oiedsLinse mt + mea6dtd +request or accessible at                                          wws.sas.co      is and conditions.him and for electronic format
This document is issued by the Company subject to its General Conditions of Service printed overleal, available onAftention       is drawn to the limitation of liabiily, indemniication and Jursdiction issues detined
documents, subject to Terms and Conditions for Electronic Documents at www sgs.com/lerms_e—Jocumenthim,                 at the time of its intervention only and within the Imits of Clents instructions, # any. The
therein. Any holder of this documentis advised that information contained hereon teflects the Company‘s findings              all their rights and obligations uinder the transaction dassments. This document cannot
Company‘s sole responsibilty is to its Client and this document does not exonerate parties to a transaction from exercising                                             this document is untawiul and offenders may be
be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsifeation of the content or appearanceof
prosecuted to the fullest extent of the law.
                             SGS Taiwan Ltd.        No.134,Wu Kung Road, New Taipei Industrial Park, Wuku District, New Taipei City, Taiwan 24803/M at ir 3.A Fii & & MC x 3 134 8t
              6 Mlelie®tBBind MS                    1 (886—2) 2209—3279                      1(886—2) 2298—0488                www.twsgs.com

                                                |                                                                                                Member of SGS Group


                                                                                                                                                 Report No. : EN/2019/60025
                                                                                                                                                 Rev: 01
                                                                                                                                                 Page:          5      of      15




                                    4. AD—Converter Values with inputs shorted
                                         DASY measurement parameters: Auto Zero Time: 3 sec; Measuring time: 3 sec

                                                                                              High Range (LSB)                      Low Range (LSB)

                                          Channel X                                                  16223                               16385

                                         Channel Y                                                    15954                              15977

                                         Channel Z                                                    15878                              16167



                                    5. Input Offset Measurement
                                         DASY measurement parameters: Auto Zero Time: 3 sec; Measuring time: 3 sec
                                         Input 10MA

                                                                    Average (uV)          min. Offset (xV)        max. Offset (uV)        Std. [;:\Biafion

                                         Channel X                       —0.02                  4116                    0.89                    0.36

                                         Channel Y                       0.99                   215                        3.08                 0.60

                                         ChannelZ                        0.49                   —0.57                   2.90                     0.62



                                    6. Input Offset Current
                                         Nominal Input circuitry offset current on all channels: <25fA



                                    7. Input Resistance (Typical values for information)
                                                                                            Zeroing (kOhm)                         Measuring (MOhm)
                                         Channel X                                                  200                                   200
                                         Channel Y                                                  200                                   200
                                         Channel Z                                                  200                                   200


                                   8. Low Battery Alarm Voltage (Typical values for information)
                                         Typical values                                     Alarm Level (VDC)

                                         Supply (+ Vee)                                                                     +7.9

                                         Supply (— Vee)                                                                     —7.6


                                   9. Power Consumption (Typical values for information)
                                         Typical values                              Switched off (m¥)        Stand by (m¥)           Transmitting (mA)
                                         Supply (+ Vee)                                     +0.01                     +6                      +14

                                         Supply (— Vee)                                     —0.01                     —8                        —9




                                   Certficate No: DAE4—856_Apr19                                    Page 5 of 5




Uniess otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only.
Beobsnmrees — Heee he miee mtehmmcee + msediaie oys + o d disp RL inmar ie + ol aSete >                                                                      .
This document is issued by the Company subject to its General Conditions of Service printed overleat,       available on request or accessible at www.sgs.comfterms       and conditions.him and for electronic format
documents, subject to Terms and Conditions for Electronic Documents at                  .comften       iocument         Attention is drawn to the limitation of labiBty, indemnification and jurisciction issues detined
                                                                                                    Company‘s findings at the time of its intervention only and within the limits of Clent‘s instructions,    if any. The
therein. Any holder of this document is advised that information contained hereon reflects the                from exercising all their rghts and obligations under the transaction documents. This cecument cannot
Company‘s sole responsibilty is to its Client and this document does not exonerate parties to a transactionforgery   or falsifcation of the content or appearanceof this document is unlawful and offenders may be
be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration,
prosecuted to the fullest extent of the law.
                                        No.134.Wu Kung Road, New Taipei Industrial Park, Wuku District, New Taipei City, Taiwan 24803/¥5 at ir TE Ni & &
                             SGS Taiwan Ltd.                                                                                                                                                         BE x36 134 &

                                                  1 (886—2) 2299—3279            1 (B86—2) 2298—0488               www.tw.ags.com
              67Motlictttiefirt MRA S
                                      I                                                                             Member of SGS Group


                                                                                                                                                              Report No. : EN/2019/60025
                                                                                                                                                              Rev: 01
                                                                                                                                                              Page: 6                   of       15




                                        Calibration
                                              —     Laboratory of                                         «(0%
                                                                                                          l                                                R             idint
                                        Schmid & Partner                                                  N                                        S Schweizerischer Kalibrierdienst
                                                                                                                                                   . Service suissed‘étatonnage
                                           Engineering AG                                                                                               Servizio svizzero di taratura
                                        Zoughausstrasse 43, 8004 Zurich, Switzorland                                                               5 Swiss
                                                                                                                                                        SotccCatwat        h
                                                                                                                                                           Calibration Service

                                        Acoredited by the Swiss Accreditalion Service (SAS)                                                        Accreditation No.: SCS 0108
                                        The Swiss Accreditation Service is one of the signatories to the EA
                                        Multiateral Agreement for the recognition of calibration certificates
                                        Ciient           (SGS—TW (Auden)                                                               Gertificate No: EX3—3770_Apr19

                                       IvCALlBRATION CERTIFICATE                                                                                                                             ]
                                        | object                              ExapVvaSh:3770

                                         Gaitbration procedure(s)             QAICAL—O1.M9; OA CAL12.v9, OA CAL14.v5, OA CAL—23v5,
                                                                              QA CAL25v7
                                                                              Calibration procedure for dosimetric E—field probes

                                         Calibration date:                    April 29, 2019

                                         This calibration certficate documents the traceabilty to national standards, which realizethe physical units of measurements (S1)
                                         The measurements and the uncertainties wih confidence probabilty are given on the following pages and are part ofthe certficale.

                                         All allbrations have been conducted in the closed laboratory faciity. environment temperature (22 + 3)°C and hurmidty < 70%

                                         Calibration Equipment used (M&TE crtical for caltration)


                                         Primary Standards                   io                                Gal Date (Gertiicate No.)                  Scheduled Galtoration
                                         Power meter NRP                     sh: toar7e                        03—Ap—19 (No. 217—02802002009)             Apr20
                                         Power sensor NRP—291                Sh: tosata                        03—Apr—19 (No. 217—02802)                  Apr20
                                         Power sensor NRP—291                Sh: 10325                         03—Ap—19 (No. 217—02809)                   Ape20
                                         Reference 20 dB Attenuator          Sh: sear? 204                     Od—Apr—19 (No. 217—02894)                  Ape20
                                         oa€4                                EME                               19—Dec—18 (No. DAE4—660_ Dect8)            Dec—19
                                         Reference Probe ES3DV2              sh sots                           31—Dec—18 (No. ES3—3013_Dect)              Dec—19

                                         Secondary Standards                 io                                Check Date (in house)                      Scheduled Check
                                         Power meter E44198                  sn    caetassora                  06—Apr—16 (in house check Jun—18)          in house checks Jun—20
                                         Power sensor E4412A                 SN:   MY4tdgso87                  06—Apr—16 (in house check Jun—18)          in house checke Jun—20
                                         Power sensor E4412A                 Sht   000110210                   06—Apr—16 (ihouse check Jun—18)            in house checks Jun—20
                                         RF generator HP 8648C               sn    ussee2u01700                04—Aug—99 (in house check Jun—16)          in house checks Jun—20
                                         Network Analyzer EG358A             Sht   us4toso477                  31—Mar—14 (in house check Oct—18)          in house check; Oct—19
                                                                               Name                                   Function                                ignatire
                                         Galibrated by:                        Glaudio Leubler                        Caboratory Techniclan

                                         Approved by:                          Kalle Pokovic                          Technical Manager                 %g


                                                                                                                                                            Issued April 30, 2019
                                         This callbration certficate shall not be reproduced except in fll without written approval ofthe laboratory.



                                        Certiicate No: EX3—3770_Aprt9                                        Page 1 of 10




Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only.
BobSein. meeeieenneiemet > eeviipeiain roor » dieLcAcereirer > rorastite —
This document is issued by the Company subject to its General Conditions of Service printed overleal, available on request or accessible at www.sgs.comferms and conditions.him and for electronic format
documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms e—documenthim, Aftention is drawn to the limitation of labiity, indemnification and jurisdiction issues defined
therein. Any holder of this document is advised that information contained hereon reflects the Company‘s findings at the time of its intervention only and within the limits of Client‘s instructions, if any. The
Company‘s sole responsibilty is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot
be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsifcation of the content or appearanceof this document is unfawful and offenders may be
prosecuted to the fullest extent of the law.
                            SGS Taiwan Ltd.            No.134,Wu Kung Road, New Taipei Industrial Park, Wuku District, New Taipei City, Taiwan 24803/ak ir %.M% 0 #rak & # )(E x i6134
             6 MMoticttBieid PRar s1                   1 (B86—2) 2200.s279                                     1 (Bas—2) 22es—0488                         wwwetw.ags.com
                                                   |                                                                                                       Member of SGS Group


                                                                                                                                                 Report No. : EN/2019/60025
                                                                                                                                                 Rev: 01
                                                                                                                                                 Page: 7                 of   15




                                          Calibration Laboratory of                                   a2                                 . Sehweizerischer Kallbrierdienst
                                          Schmid & Partner                                            SBE//M                             (G Service suisse d‘étalonnage
                                            Engineering AG                                            esnt                               g.   Servizio svizzero di taratura
                                          Zoughausstrasse 43, 8004 Zurich, Switzerland                *///,?\\\                               Swiss Calibration Service


                                           Aceredted by the Swiss Accreditation Service (SAS)                                             Accreditation No.: SCS 0108
                                          The Swiss Accreditation Service is one of the signatories to the EA
                                          Multiateral Agreement for the recognition of calibration certificates
                                          Glossary:
                                          TSL                          tissue simulating liquid
                                          NORMx,y,2                    sensitivity in free space
                                          ConvF                        sensitivity in TSL / NORMxy,z
                                          DCP                          diode compression point
                                          CF                           crest factor (1/duty_cycle) of the RF signal
                                          A, B, C, D                   modulation dependent linearization parameters
                                          Polarization p               ip rotation around probe axis
                                          Polarization 8               8 rotation around an axis that is in the plane normal to probe axis (at measurement center),
                                                                       ie., 8 = 0 is normal to probe axis
                                          Connector Angle              information used in DASY system to align probe sensor X to the robot coordinate system

                                          Calibration is Performed According to the Following Standards:
                                               a)—   IEEE Std 1528—2013, ‘IEEE Recommended Practice for Determining the Peak Spatial—Averaged Specific
                                                     Absorption Rate (SAR) in the Human Head from Wireless Communications Devices: Measurement
                                                     Techniques®, June 2013
                                               b)    IEC 62209—1, ", "Measurement procedure for the assessment of Specific Absorption Rate (SAR) from hand—
                                                     held and body—mounted devices used next to the ear (frequency range of 300 MHz to 6 GHz)*, July 2016
                                               c)    IEC 62209—2, "Procedure to determine the Specific Absorption Rate (SAR) for wireless communication devices
                                                     used in close proximity to the human body (frequency range of 30 MHz to 6 GHz)", March 2010
                                               d)    KDB 865664, ‘SAR Measurement Requirements for 100 MHz to 6 GHz"
                                          Methods Applied and Interpretation of Parameters:
                                                     NORMx,y,z: Assessed for E—field polarization 8 = 0 (f < 900 MHz in TEM—cell; £> 1800 MHz: R22 waveguide)
                                                     NORMx,y,z are only intermediate values, L.e., the uncertainties of NORMx,y,z does not affect the E*—field
                                                     uncertainty inside TSL (see below ConvF).
                                                     NORM(Mx,y,z = NORMxy,z * frequency_response (see Frequency Response Chart). This linearization is
                                                     implemented in DASY4 software versions later than 4.2. The uncertainty of the frequency response is included
                                                     in the stated uncertainty of ConvF.
                                                     DCPxy,z: DCP are numerical linearization parameters assessed based on the data of power sweep with CW
                                                     signal (no uncertainty required). DCP does not depend on frequency nor media.
                                                     PAR: PAR is the Peak to Average Ratio that is not calibrated but determined based on the signal
                                                     characteristics
                                                     Auy.z Buy.z: Cuy.z; Dxy,2: VRxy.z: A, 8. C, D are numerical linearization parameters assessed based on
                                                     the data of power sweep for specific modulation signal. The parameters do not depend on frequency nor
                                                     media. VR is the maximum calibration range expressed in RMS voltage across the diode.
                                                     ConvF and Boundary Effect Parameters: Assessed in flat phantom using E—field (or Temperature Transfer
                                                     Standard for f < 800 MHz) and inside waveguide using analytical field distributions based on power
                                                     measurements for f > 800 MHz. The same setups are used for assessment of the parameters applied for
                                                     boundary compensation (alpha, depth) of which typical uncertainty values are given. These parameters are
                                                     used in DASY4 software to improve probe accuracy close to the boundary. The sensitivity in TSL corresponds
                                                     to NORMx,y,z * Conv whereby the uncertainty corresponds to that given for ConvF. A frequency dependent
                                                     ConvF is used in DASY version 4.4 and higher which allows extending the validity from + 50 MHz to + 100
                                                     MHz.
                                                     Sphericalisotropy (3D deviation from isotropy): in a field of low gradients realized using a flat phantom
                                                     exposed by a patch antenna.
                                                     ‘Sensor Offset: The sensor offset corresponds to the offset of virtual measurement center from the probe tip
                                                     (on probe axis). No tolerance required.
                                                     Connector Angle: The angle is assessed using the information gained by determining the NORMx (no
                                                     uncertainty required).



                                          Certificate No: EX3—3770_Apri9                                 Page 2 of 10




Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only.
BohSstee . mineennzse > Reinesier roor + dtencAcermite > moeoiee >
This document is issued by the Company subject to its General Conditions of Service printed overleal, available on request or accessible at www.sgs.comferms and conditions.him and for electronic format
documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms e—documenthtm, Attention is drawn to the limitation of labilty, indemnification and jurisdiction issues detined
therein. Any holder of this document is advised that information contained hereon reflects the Company‘s findings at the time of its intervention only and within the Imits of Client‘s instructions, if any. The
Company‘s sole responsibilty is to its Client and this document doss not exonerate paties to a transaction from exercising alltheir rights and obligations under the transaction documents. This document cannot
be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsifcation of the content or appearanceof this document is unlawlul and offenders may be
prosecuted to the fullest extent of the law.
                              SGS Taiwan Ltd.        No.134,Wu Kung Road, New Taipei Industrial Park, Wuku District, New Taipei City, Taiwan 24803/ak ir %.M% 0 #rak & # )(E x i6134
              6 MMoticttBieid PRar s1                t (B86—2) 2200.s279                                  1 (B86—2) 2208—0488                 www.tw.egs.com
                                                                                                                                              Member of SGS Group


                                                                                                                                                           Report No. : EN/2019/60025
                                                                                                                                                           Rev: 01
                                                                                                                                                           Page : 8 of 15




                                          EX3DV4 — SN:3770                                                                                                              April 29, 2019


                                           DASY/EASY — Parameters of Probe: EX3DV4 — SN:3770
                                          Basic Calibration Parameters
                                                                                         Sensor x                       SensorY                       Sensorz               Une (k=2)
                                               Norm (gVI(Vien))"                           030                            059                           0.30                £10.1%
                                               DCP (mV)"                                   1044                           1034                          989

                                          Calibration Results for Modulation Response
                                           uin      Communication System Name      A                                       Bs          c          b         vr          Max     ~| Une"
                                                                                                             dB        dBy                       dB         mV          dev.       (k=2)
                                               0         Cw                                        x         00           00          10        o00        f60s       127%        £47%
                                                                                                   Y         00           00          10                   To
                                                                                                   ¥         0.0          0.0         10                   T586


                                               The reported uncertainty of measurement is stated as the standard uncertainty of measurement
                                               multiplied by the coverage factor k=2, which for a normal distribution corresponds to a coverage
                                               probability of approximately 95%.


                                          *‘The uncertainties of Norm X¥,2 do not affectthe E—feld uncertainty nside TL (see Pages 5 and 6)
                                          * Numericalinearization parameter: uncertainty not required.
                                          * Uncertainty s determined using the max. deviation from linear response applying rectangular distrbution and is expressed for the square ofthe
                                          field value;




                                          Certificate No: EX3—3770_Apri9                                   Page 3 of 10




Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only.
BohSstee . mineennzse > Reinesier roor + dtencAcermite > moeoiee >
This document is issued by the Company subject to its General Conditions of Service printed overleal, available on request or accessible at www.sgs.comferms and conditions.him and for electronic format
documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms e—documenthtm, Attention is drawn to the limitation of labilty, indemnification and jurisdiction issues detined
therein. Any holder of this document is advised that information contained hereon reflects the Company‘s findings at the time of its intervention only and within the Imits of Client‘s instructions, if any. The
Company‘s sole responsibilty is to its Client and this document doss not exonerate paties to a transaction from exercising alltheir rights and obligations under the transaction documents. This document cannot
be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsifcation of the content or appearanceof this document is unlawlul and offenders may be
prosecuted to the fullest extent of the law.
                              SGS Taiwan Ltd.        No.134,Wu Kung Road, New Taipei Industrial Park, Wuku District, New Taipei City, Taiwan 24803/ak ir %.M% 0 #rak & # )(E x i6134
              6 MMoticttBieid PRar s1                1 (886—2) 2290—3279                                     1 (B86—2) 2298—0488                        www.twags.com
                                                                                                                                                         Member of SGS Group


                                                                                                                                              Report No. : EN/2019/60025
                                                                                                                                              Rev: 01
                                                                                                                                              Page: 9               of      15




                                        EX3DV4~ SN:3770                                                                                                  April 29, 2019


                                        DASY/EASY — Parameters of Probe: EX3DV4 — SN:3770

                                        Other Probe Parameters
                                         Sensor Arrangement                                                                                                Triangular

                                         Connector Angle (°)                                                                                                    —34.6
                                         Mechanical Surface Detection Mode                                                                                   enabled
                                         Optical Surface Detection Mode                                                                                      disabled
                                         Probe Overall Length                                                                                                337 mm
                                         Probe Body Diameter                                                                                                  10 mm
                                         Tip Length                                                                                                             9 mm
                                         Tip Diameter                                                                                                         2.5 mm
                                         Probe Tip to Sensor X Calibration Point                                                                                1 mm
                                         Probe Tip to Sensor Y Calibration Point                                                                                1 mm
                                         Probe Tip to Sensor Z Calibration Point                                                                                1 mm
                                         Recommended MeasurementDistance from Surface                                                                         14 mm




                                        Certificate No: EX3—3770_Apri9                             Page 4 of 10




Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only.
BobSein. meeeieenneiemet > eeviipeiain roor » dieLcAcereirer > rorastite —
This document is issued by the Company subject to its General Conditions of Service printed overleal, available on request or accessible at www.sgs.comferms and conditions.him and for electronic format
documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms e—documenthim. Attention is drawn to the limitation of labilty, indemnification and jurisdiction issues detined
therein. Any holder of this document is advised that information contained hereon reflects the Company‘s findings at the time of its intervention only and within the limits of Client‘s instructions, if any. The
Company‘s sole responsibilty is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot
be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsifcation of the content or appearanceof this document is unfawful and offenders may be
prosecuted to the fullest extent of the law.
                            SGS Taiwan Ltd.      No.134,Wu Kung Road, New Taipei Industrial Park, Wuku District, New Taipei City, Taiwan 24803/ak ir %.M% 0 #rak & # )(E x i6134
             6 MMoticttBieid PRar s1            1 (886—2) 2290—3279                                 1 (806—2) 2298—0488                    www.tw.ags.com
                                                                                                                                           Member of SGS Group


                                                                                                                                                   Report No. : EN/2019/60025
                                                                                                                                                   Rev: 01
                                                                                                                                                   Page: 10                   of      15




                                        EX3DV4— SN:3770                                                                                                          April 29, 2019




                                        DASY/EASY — Parameters of Probe: EX3DV4 — SN:3770

                                        Calibration Parameter Determined in Head Tissue Simulating Media
                                                              Relative        Conductivity                                                           Depth            Une
                                             £(MHz)°_|_     Permittivity®         (Sim)"         ConvFX       ConvFY        |_GonvFZ     Aipha®        |__(mm)        (ke2)

                                                   450          435                0.87           10.97         10.97         10.97        041         130          +133%
                                                   750          41.9               0.89            9.68         a.68          a.68         0.57        a.91_|       £120%
                                                   835          41.5               0.90            9.44         9.44          9.44         0.58        0.80         £120%
                                                   900          41.5               0.97,           9.22         9.22          9.22         o.ss        0.80         £120%
                                               1750             40.1               1.37,           8.44         8.44          844          0.32        0.97         £120%
                                               1900             40.0               1.40            823          823           8.23         0.36        085          £120%
                                               2000             40.0               140             8.13         8.13          8.13         0.41        085          +120%
                                               2300             30.5               1.67            7e4          744           784          0s3         as8          £120%
                                               2450             30.2               1.80            748           748          748          0.31        o88          +120%
                                               2600             30.0               1.96            7.30          7.30         7.s0         0.46        082          £120%
                                               4100             37.2               3.53            26            5.26         6.26         0.40        1120         £13.1%
                                               4200             37.1               .63             6.12          6.12         6.12         0.40        130          $18.1%
                                               4600             36.7               4.04            6.09          6.09         5.09         0.45        160|         £18.1%
                                               4950             36.3               4.40            5.61          5.61         561          0.40        180|         £18.1%
                                               5250             35.9               4.              5.30          5.30         5.30         0.40        1.80         13.1%
                                               5600             355                5.07            4.82         4.82          4.82         0.40        180          £131%
                                               s7s0             364                5.22            5.12          5.12         542          0.40        180          £18.1%

                                        © Frequency valiity above 300 MHz of + 100 MHz only applies for DASY v4.4 and higher (see Page 2), else ts restrted to + 50 MHz. The
                                        uncertainty is the RSS of the Convuncertaiy atcallbraton frequency and the uncertainty for the indlealed frequency band. Frequency valdlty
                                        below 300 Mz is % 10, 25, 40, 50 and 70 Mz for ConvF assessments at 30, 64, 128, 150 and 220 Mz respectively. Validly of Conve assessed at
                                        6 MHz is 4—9 MH, and Convassessed at 13 MHzis 9—19 MHz. Above 5 GHz frequency valdty can be extended to + 110 Miz.
                                        Atfrequencies below 3 GHz, he vallly of tssue parameters (e and a) can be relexed to + 10% if iquid compensation formula is applied to
                                        measured SAR values. Atfrequencies above 3 GHz,the validly oftssue parameters (c and 0)is resticted to + 5%. The uncertaity is the RSS of
                                        the ConvE uncertaintyfor indicated target fissue parameters.
                                        © Apha/Depth are determined during calbration. SPEAG warrants that the remaining deviation due to the boundary effect after compensation is
                                        always less than + 1% forfrequencies below 3 GHz and below + 2% for requencies between 3.6 GHz at any distance larger than halfthe probe tp
                                        diameterfrom the boundary.




                                        Certificate No: EX3—3770_Apri9                                Page 5 of 10




Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only.
BobSein. meeeieenneiemet > eeviipeiain roor » dieLcAcereirer > rorastite —
This document is issued by the Company subject to its General Conditions of Service printed overleal, available on request or accessible at www.sgs.comferms and conditions.him and for electronic format
documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms e—documenthim, Aftention is drawn to the limitation of labiity, indemnification and jurisdiction issues defined
therein. Any holder of this document is advised that information contained hereon reflects the Company‘s findings at the time of its intervention only and within the limits of Client‘s instructions, if any. The
Company‘s sole responsibilty is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot
be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsifcation of the content or appearanceof this document is unfawful and offenders may be
prosecuted to the fullest extent of the law.
                            SGS Taiwan Ltd.         No.134,Wu Kung Road, New Taipei Industrial Park, Wuku District, New Taipei City, Taiwan 24803/ak ir %.M% 0 #rak & # )(E x i6134
             6 MMoticttBieid PRar s1               1 (B86—2) 2200.s279                                  1 (Bas—2) 22es—0488                       wwwetw.ags.com
                                               |                                                                                                  Member of SGS Group


                                                                                                                                                     Report No. : EN/2019/60025
                                                                                                                                                     Rev: 01
                                                                                                                                                     Page: 11                  of       15




                                        EX3DVA— SN:3770                                                                                                            Apri 20, 2019




                                        DASY/EASY — Parameters of Probe: EX3DV4 — SN:3770

                                        Calibration Parameter Determined in Body Tissue Simulating Media
                                                               Relative        Conductivity                                                            Depth            Une
                                              1(MHz) _|_Pormittivity"              (Sim)"         ConvX         ConvFY        ConvEZ       Aipha®        |__(mm)       (ke2)
                                                   450           56.7               0.94            10.64         10.64        10.64         0.08        130         i133%
                                                   750           55.5               0.96            10.02         10.02        10.02         0.53        o83         £120%
                                                   835           552                0.97            9.60          9.60          9.60         0.53        0.81        +12.0 %
                                                   900           55.0               1.05            5.53          9.53          9.53         0.42        o.87        £120%
                                                1750             534                149             8.09          8.00          8.00         045         085         £120%
                                                1900             58.3               152             782           782           782          0.20        0.%9        £120%
                                               2000              53.3               162             7.76          776           7.76         0.40        085         £120%
                                               2300              52.9               1.41            7.68          7.68          7.68         0.37        088         £120%
                                               2450              52.7               1.95            741           7ai           741          0.32        0.4         £120%
                                               2600              52.5               216             728           728           728          0.31        0.94        £120%
                                               4100              50.5               4.01            6.21          6.21          6.21         0.30        150         £131%
                                               4200              50.4               4.13            6.09          6.09          6.09         0.30        150         £18.1%
                                               4600              49.8               4.60            5.78          5.78          5.78         0.40        150|        £13.1%
                                               4950              49.4               5.01            5.24          5.24          5.24         0.50        180         £131%
                                               5250              48.9               536             4.61          4.61         4.61         0.50         190         £131%
                                               5600              485                5.77            4.05          4.05         4.05         0.50         190         £181%
                                               5750              48.3               5.04            4.38          4.38         4.38         0.50         190         +18.1%

                                        © Frequency valdity above 300 MHz af + 100 MHz only applies for DASY v4.4 and higher (see Page 2}, elsets restreted to + 50 MHz. The
                                        uncertainlyis the RSS of the Conve uncertainty at caloration frequency and the uncertainty for the indicate frequency band. Frequency validty
                                        below 300 MHz is + 10, 28, 40, 50 and 70 Mz for Conv: assessments at 30, 64, 128, 150 and 220 Mz respectively. Valldty of Convassessed at
                                        8 MHz is 4—9 MHz, and Conv® assessed at 13 MHz is 9—10 MHz. Above 5 GHNz frequency valily can be extended to + 110 Mz
                                        Atrequencies below 3 GH, the valdty of issue parameters (e and a) can be relared to + 10% ifiquid compensation fomula is appled to
                                        measured SAR values. Al frequencies above 3 GHtz,the validty oftisue parameters (c and a) is resticted to + 5%. The uncertainty is the RSS of
                                        the Conv uncertainty forindicated target tssue parameters.
                                        * AlphalDepth are determined durng calibration. SPEAG warrants that the remaining devialion due to the boundary effect after compansation is
                                        always less than + 1% for requencies below 3 GHiz and below + 2% forfrequencies between 3—6 GHz at any distance larger than halfthe probe tip
                                        diameter rom the boundary.




                                        Certiicate No: EX3—3770_Apr19                                  Page 6 of 10




Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only.
BobSein. meeeieenneiemet > eeviipeiain roor » dieLcAcereirer > rorastite —
This document is issued by the Company subject to its General Conditions of Service printed overleal, available on request or accessible at www.sgs.comferms and conditions.him and for electronic format
documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms e—documenthim, Aftention is drawn to the limitation of labiity, indemnification and jurisdiction issues defined
therein. Any holder of this document is advised that information contained hereon reflects the Company‘s findings at the time of its intervention only and within the limits of Client‘s instructions, if any. The
Company‘s sole responsibilty is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot
be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsifcation of the content or appearanceof this document is unfawful and offenders may be
prosecuted to the fullest extent of the law.
                            SGS Taiwan Ltd.        No.134,Wu Kung Road, New Taipei Industrial Park, Wuku District, New Taipei City, Taiwan 24803/ak ir %.M% 0 #rak & # )(E x i6134
             6 MMoticttBieid PRar s1               1 (B86—2) 2200.s279                                   1 (Bas—2) 22es—0488                        wwwetw.ags.com
                                               |                                                                                                    Member of SGS Group


                                                                                                                                                              Report No. : EN/2019/60025
                                                                                                                                                              Rev: 01
                                                                                                                                                              Page: 12               of   15




                                        EX3DV4— SN:3770                                                                                                                 April 20, 2019




                                                                                                  Frequency Response of E—Field
                                                                                                                            1110 EXX, Waveguide: R22)
                                                     Frequency response (normalized)




                                                                                       FGdtn         frnaiednernmate

                                                                                       0.9




                                                                                                                        i                                      i          i
                                                                                                    T              T                t          t                    t
                                                                                             0     500           1000             1500       2000                  3000

                                                                                                           Lo
                                                                                                           Tem
                                                                                                 Uncertainty of Frequency Response of E—field: 2 6.3% (k=2)




                                        Certificate No: EX3—3770_Apr19                                                        Page 7 of 10




Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only.
BohSstee . mine en nzse > Reinesier roor + d t encA cermite > moeoiee >
This document is issued by the Company subject to its General Conditions of Service printed overleal, available on request or accessible at www.sgs.comferms and conditions.him and for electronic format
documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms e—documenthtm, Aftention is drawn to the limitation of fabilty, indemnification and Jurisdiction issues detined
therein. Any holder of this document is advised that information contained hereon reflects the Company‘s findings at the time of its intervention only and within the Imits of Client‘s instructions, if any. The
Company‘s sole responsibilty is to its Client and this document doss not exonerate paties to a transaction from exercising alltheir rights and obligations under the transaction documents. This document cannot
be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsifcation of the content or appearanceof this document is unlawlul and offenders may be
prosecuted to the fullest extent of the law.
                             SGS Taiwan Ltd.        No.134,Wu Kung Road, New Taipei Industrial Park, Wuku District, New Taipei City, Taiwan 24803/ak ir %.M% 0 #rak & # )(E x i6134
             6 MMoticttBieid PRar s1                1 (B86—2) 2200.s279                                                        1 (Bas—2) 22es—0488        wwwetw.ags.com
                                                |                                                                                                         Member of SGS Group


                                                                                                                                                 Report No. : EN/2019/60025
                                                                                                                                                 Rev: 01
                                                                                                                                                 Page: 13             of     15




                                          EX3DV4— SN:3770                                                                                                April 29, 2019




                                                                              Receiving Pattern (¢), 8 = 0°

                                                                   £=600 MHz,TEM                                               £=1800 MHz,R22




                                                        *               s           s             &                   &                          s
                                                       To               x           v             z                  To                          v




                                                      as           i          m              daemmmseimit

                                                 €0|        j   ]   .   1        ‘
                                                 3 0 o1m4§i—ttflfirwaig¢w¥*—fiw:w:fifi$¥
                                                 &         t       i
                                                     asd
                                                           Eulc         h d uc hoge
                                                                               t    io         i bopuitcs i               u4d i 0640406     04204200 030050
                                                                                                                                                         i
                                                                  150         100             o            0                  so        100             150
                                                                                                         Rol P
                                                                                             600 Niz

                                                                            Uncertainty of Axial Isotropy Assessment: £ 0.5% (k=2)




                                          Certificate No: EX3—3770_Apri9                              Page 8 of 10




Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only.
BohSstee . mineennzse > Reinesier roor + dtencAcermite > moeoiee >
This document is issued by the Company subject to its General Conditions of Service printed overleal, available on request or accessible at www.sgs.comferms and conditions.him and for electronic format
documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms e—documenthtm, Attention is drawn to the limitation of labilty, indemnification and jurisdiction issues detined
therein. Any holder of this document is advised that information contained hereon reflects the Company‘s findings at the time of its intervention only and within the Imits of Client‘s instructions, if any. The
Company‘s sole responsibilty is to its Client and this document doss not exonerate paties to a transaction from exercising alltheir rights and obligations under the transaction documents. This document cannot
be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsifcation of the content or appearanceof this document is unlawlul and offenders may be
prosecuted to the fullest extent of the law.
                              SGS Taiwan Ltd.       No.134,Wu Kung Road, New Taipei Industrial Park, Wuku District, New Taipei City, Taiwan 24803/ak ir %.M% 0 #rak & # )(E x i6134
              6 MMoticttBieid PRar s1               1 (B86—2) 2200.s279                                1 (Bas—2) 22es—0488                    wwwetw.ags.com
                                                |                                                                                             Member of SGS Group


                                                                                                                                                             Report No. : EN/2019/60025
                                                                                                                                                             Rev: 01
                                                                                                                                                             Page: 14                of   15




                                        EX3DV4~ SN:3770                                                                                                                 April 29, 2019




                                                                                                    Dynamic Range f(SARneaq)
                                                                                                              (TEM cell , feyai= 1900 MHz)
                                                             Input Signal fuV)




                                                                                            108        102         10            10       10           10          10
                                                                                                                         SAR {mWiom9]
                                                                                                       not compensated                    compensated
                                                                                 Eror [B]




                                                                                             103        tor        101          10      101       10°        103
                                                                                                                         SAR [mWiem]
                                                                                                             C+]
                                                                                                       not compansated                   compensated

                                                                                                   Uncertainty of Linearity Assessment: £ 0.6% (k=2)




                                        Certificate No: EX3—3770_Aprt9                                                   Page 9 of 10




Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only.
BohSstee . mine en nzse > Reinesier roor + d t encA cermite > moeoiee >
This document is issued by the Company subject to its General Conditions of Service printed overleal, available on request or accessible at www.sgs.comferms and conditions.him and for electronic format
documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms e—documenthtm, Aftention is drawn to the limitation of fabilty, indemnification and Jurisdiction issues detined
therein. Any holder of this document is advised that information contained hereon reflects the Company‘s findings at the time of its intervention only and within the Imits of Client‘s instructions, if any. The
Company‘s sole responsibilty is to its Client and this document doss not exonerate paties to a transaction from exercising alltheir rights and obligations under the transaction documents. This document cannot
be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsifcation of the content or appearanceof this document is unlawlul and offenders may be
prosecuted to the fullest extent of the law.
                             SGS Taiwan Ltd.        No.134,Wu Kung Road, New Taipei Industrial Park, Wuku District, New Taipei City, Taiwan 24803/ak ir %.M% 0 #rak & # )(E x i6134
             6 MMoticttBieid PRar s1                1 (B86—2) 2200.s279                                                   1 (Bas—2) 22es—0488               wwwetw.ags.com
                                                |                                                                                                           Member of SGS Group


                                                                                                                                                   Report No. : EN/2019/60025
                                                                                                                                                   Rev: 01
                                                                                                                                                   Page: 15 of 15




                                           EX3DV4— SN:3770                                                                                              Aprl 28, 2019




                                                                                Conversion Factor Assessment
                                                             1= 835 MHz.WGLS RO (H_conv)                                1= 1900 MHz.WGLS R22 (H_conv?)




                                                                               Deviation from Isotropy in Liquid
                                                                                              Error(¢, 8), £= 900 MHz
                                                                    Devation




                                                                         410      —08   08    ~04   020     00    020    04     os    os      10
                                                                               Uncertainty of Spherical Isotropy Assessment: £ 2.6% (k=2)


                                           Certiicate No: EX3—3770_Apri9                             Page 10 of 10




                                                                                          — End of report —

Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only.
borstm® . ie emet nzim — Eeieaiir roon » d EhLiA cereite > neieie —
This document is issued by the Company subject to its General Conditions of Service printed overleal, available on request or accessible at www.sgs.comterms and conditions.htm and for electronic format
documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms e—document/htm. Attention is drawn to the limitation of labiity, indemnification and jurisciction issues detined
therein. Any holder of this document is advised that information contained hereon reflects the Company‘s findings at the time of its intervertion only and within the Imits of Client‘s instructions, if any. The
Company‘s sole responsibilty is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot
be reproduced excpt in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unfawul and offenders may be
prosecuted to the fullest extent of the law.
                             SGS Taiwan Ltd.      No.134,Wu Kung Road, New Taipei Industrial Park, Wuku District, New Taipei City, Tawan 24803/at i 2. M ts 4 4t & # @ (s % 3 134 3
             6 MMoticttBieid PRar s1              t (B86—2) 2200.s279                                     1 (Bee—2) 2208—0488                 www.tw.egs.com
                                                                                                                                              Member of SGS Group



Document Created: 2019-09-02 11:18:06
Document Modified: 2019-09-02 11:18:06