SAR Scan Plots

FCC ID: B4HBLGD900M

RF Exposure Info

Download: PDF
FCCID_3491907

Bay Area Compliance Laboratories Corp. (kunshan)                       Report No: RSZ170605831-20



DUT: FULL DUPLEX 900MHZ TRANSCEIVER-MASTER (TD 900 SERIES- M); Type: TD 900M;



Communication System: 900MHz FHSS Band; Frequency: 903 MHz;Duty Cycle: 1:42
Medium parameters used: f = 903 MHz; σ = 0.98 mho/m; εr = 41.75; ρ = 1000 kg/m3
Phantom section: Left Section

DASY4 Configuration:
- Probe: EX3DV4 – SN7431; ConvF(9.84, 9.84, 9.84); Calibrated: 04/10/2016
- Sensor-Surface: 4mm (Mechanical Surface Detection)
- Electronics: DAE – SN772; Calibrated: 25/10/2016
- Phantom: TWIN SAM; Type: Twin SAM V5.0; Serial: 1909
- Measurement SW: DASY4, V4.5 Build 19; Postprocessing SW: SEMCAD, V1.8 Build 145



Left Cheek/FHSS Low/Area Scan (111x121x1): Measurement grid: dx=10mm, dy=10mm
Maximum value of SAR (interpolated) = 0.093 mW/g

Left Cheek/FHSS Low/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm
Reference Value = 9.10 V/m; Power Drift = 0.040 dB
Peak SAR (extrapolated) = 0.112 W/kg
SAR(1 g) = 0.086 mW/g; SAR(10 g) = 0.062 mW/g
Maximum value of SAR (measured) = 0.092 mW/g




SAR Plots                                                                               Plot No.: 1#


Bay Area Compliance Laboratories Corp. (kunshan)                       Report No: RSZ170605831-20



DUT: FULL DUPLEX 900MHZ TRANSCEIVER-MASTER (TD 900 SERIES- M); Type: TD 900M;



Communication System: 900MHz FHSS Band; Frequency: 915 MHz;Duty Cycle: 1:42
Medium parameters used: f = 915 MHz; σ = 0.99 mho/m; εr = 41.85; ρ = 1000 kg/m3
Phantom section: Left Section

DASY4 Configuration:
- Probe: EX3DV4 – SN7431; ConvF(9.84, 9.84, 9.84); Calibrated: 04/10/2016
- Sensor-Surface: 4mm (Mechanical Surface Detection)
- Electronics: DAE – SN772; Calibrated: 25/10/2016
- Phantom: TWIN SAM; Type: Twin SAM V5.0; Serial: 1909
- Measurement SW: DASY4, V4.5 Build 19; Postprocessing SW: SEMCAD, V1.8 Build 145



Left Cheek/FHSS Mid/Area Scan (111x121x1): Measurement grid: dx=10mm, dy=10mm
Maximum value of SAR (interpolated) = 0.070 mW/g

Left Cheek/FHSS Mid/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm
Reference Value = 8.01 V/m; Power Drift = -0.114 dB
Peak SAR (extrapolated) = 0.091 W/kg
SAR(1 g) = 0.066 mW/g; SAR(10 g) = 0.046 mW/g
Maximum value of SAR (measured) = 0.070 mW/g




SAR Plots                                                                               Plot No.: 2#


Bay Area Compliance Laboratories Corp. (kunshan)                       Report No: RSZ170605831-20



DUT: FULL DUPLEX 900MHZ TRANSCEIVER-MASTER (TD 900 SERIES- M); Type: TD 900M;



Communication System: 900MHz FHSS Band; Frequency: 927 MHz;Duty Cycle: 1:42
Medium parameters used: f = 927 MHz; σ = 0.99 mho/m; εr = 41.25; ρ = 1000 kg/m3
Phantom section: Left Section

DASY4 Configuration:
- Probe: EX3DV4 – SN7431; ConvF(9.84, 9.84, 9.84); Calibrated: 04/10/2016
- Sensor-Surface: 4mm (Mechanical Surface Detection)
- Electronics: DAE – SN772; Calibrated: 25/10/2016
- Phantom: TWIN SAM; Type: Twin SAM V5.0; Serial: 1909
- Measurement SW: DASY4, V4.5 Build 19; Postprocessing SW: SEMCAD, V1.8 Build 145



Left Cheek/FHSS High/Area Scan (111x121x1): Measurement grid: dx=10mm, dy=10mm
Maximum value of SAR (interpolated) = 0.061 mW/g

Left Cheek/FHSS High/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm
Reference Value = 7.59 V/m; Power Drift = -0.082 dB
Peak SAR (extrapolated) = 0.074 W/kg
SAR(1 g) = 0.057 mW/g; SAR(10 g) = 0.041 mW/g
Maximum value of SAR (measured) = 0.061 mW/g




SAR Plots                                                                               Plot No.: 3#


Bay Area Compliance Laboratories Corp. (kunshan)                       Report No: RSZ170605831-20



DUT: FULL DUPLEX 900MHZ TRANSCEIVER-MASTER (TD 900 SERIES- M); Type: TD 900M;



Communication System: 900MHz FHSS Band; Frequency: 915 MHz;Duty Cycle: 1:42
Medium parameters used: f = 915 MHz; σ = 0.99 mho/m; εr = 41.81; ρ = 1000 kg/m3
Phantom section: Right Section

DASY4 Configuration:
- Probe: EX3DV4 – SN7431; ConvF(9.84, 9.84, 9.84); Calibrated: 04/10/2016
- Sensor-Surface: 4mm (Mechanical Surface Detection)
- Electronics: DAE – SN772; Calibrated: 25/10/2016
- Phantom: TWIN SAM; Type: Twin SAM V5.0; Serial: 1909
- Measurement SW: DASY4, V4.5 Build 19; Postprocessing SW: SEMCAD, V1.8 Build 145



Right Cheek/FHSS Mid/Area Scan (111x121x1): Measurement grid: dx=10mm, dy=10mm
Maximum value of SAR (interpolated) = 0.061 mW/g

Right Cheek/FHSS Mid/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm
Reference Value = 6.01 V/m; Power Drift = 0.055 dB
Peak SAR (extrapolated) = 0.069 W/kg
SAR(1 g) = 0.055 mW/g; SAR(10 g) = 0.041 mW/g
Maximum value of SAR (measured) = 0.059 mW/g




SAR Plots                                                                               Plot No.: 4#