Test Report

FCC ID: B32V200CP

Test Report

Download: PDF

                                                               FCC Test Report

                       Report No.: RF171114C19-5

                            FCC ID: B32V200CP

                       Test Model: V400c Plus

                 Received Date: Nov. 15, 2017

                         Test Date: Dec. 11, 2017 ~ Dec. 15, 2017

                     Issued Date: Dec. 27, 2017


                         Applicant: Verifone, Inc.

                          Address: 1400 West Stanford Ranch Road Suite 200 Rocklin CA 95765 USA



                        Issued By: Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch

                    Lab Address: No. 47-2, 14th Ling, Chia Pau Vil., Lin Kou Dist., New Taipei City, Taiwan
                                 ( R.O.C )
                  Test Location: No. 19, Hwa Ya 2nd Rd, Wen Hwa Tsuen, Kwei Shan Hsiang, Taoyuan
                                 Hsien 333, Taiwan, R.O.C.
            FCC Registration /
                                            788550 / TW0003
       Designation Number:




This report is for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted
only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this
report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product
unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you
provided to us. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence, provided,
however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time
shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Unless specific
mention, the uncertainty of measurement has been explicitly taken into account to declare the compliance or non-compliance to the specification. The report
must not be used by the client to claim product certification, approval, or endorsement by TAF or any government agencies.




Report No.: RF171114C19-5                                            Page No. 1 / 31                                            Report Format Version: 6.1.1


                                                                Table of Contents
Release Control Record .................................................................................................................................. 3
1 Certificate of Conformity ........................................................................................................................... 4
2 Summary of Test Results ........................................................................................................................... 5
    2.1 Measurement Uncertainty ..................................................................................................................... 5
    2.2 Modification Record .............................................................................................................................. 5
3 General Information ................................................................................................................................... 6
    3.1 General Description of EUT .................................................................................................................. 6
    3.2 Description of Test Modes..................................................................................................................... 7
        3.2.1 Test Mode Applicability and Tested Channel Detail .................................................................... 7
    3.3 Description of Support Units ................................................................................................................. 9
        3.3.1 Configuration of System under Test ........................................................................................... 9
    3.4 General Description of Applied Standards ............................................................................................ 9
4 Test Types and Results ............................................................................................................................ 10
    4.1 Radiated Emission Measurement ....................................................................................................... 10
        4.1.1 Limits of Radiated Emission Measurement .............................................................................. 10
        4.1.2 Test Instruments ........................................................................................................................ 11
        4.1.3 Test Procedures ........................................................................................................................ 12
        4.1.4 Deviation from Test Standard ................................................................................................... 12
        4.1.5 Test Set Up ............................................................................................................................... 13
        4.1.6 EUT Operating Conditions ........................................................................................................ 13
        4.1.7 Test Results .............................................................................................................................. 14
    4.2 Conducted Emission Measurement .................................................................................................... 22
        4.2.1 Limits of Conducted Emission Measurement ........................................................................... 22
        4.2.2 Test Instruments ....................................................................................................................... 22
        4.2.3 Test Procedures ........................................................................................................................ 23
        4.2.4 Deviation from Test Standard ................................................................................................... 23
        4.2.5 Test Setup ................................................................................................................................. 23
        4.2.6 EUT Operating Conditions ........................................................................................................ 23
        4.2.7 Test Results .............................................................................................................................. 24
    4.3 Frequency Stability ............................................................................................................................. 26
        4.3.1 Limits of Frequency Stability Measurement ............................................................................. 26
        4.3.2 Test Setup ................................................................................................................................. 26
        4.3.3 Test Instruments ....................................................................................................................... 26
        4.3.4 Test Procedure ......................................................................................................................... 26
        4.3.5 Deviation fromTest Standard .................................................................................................... 26
        4.3.6 EUT Operating Conditions ........................................................................................................ 26
        4.3.7 Test Result ................................................................................................................................ 27
    4.4 20 dB Bandwidth ................................................................................................................................. 28
        4.4.1 Limits of 20 dB Bandwidth Measurement ................................................................................. 28
        4.4.2 Test Setup ................................................................................................................................. 28
        4.4.3 Test Instruments ....................................................................................................................... 28
        4.4.4 Test Procedures ........................................................................................................................ 28
        4.4.5 Deviation from Test Standard ................................................................................................... 28
        4.4.6 EUT Operating Conditions ........................................................................................................ 28
        4.4.7 Test Results .............................................................................................................................. 29
5 Pictures of Test Arrangements................................................................................................................ 30
Appendix – Information on the Testing Laboratories ................................................................................ 31




Report No.: RF171114C19-5                                         Page No. 2 / 31                                          Report Format Version: 6.1.1


                                           Release Control Record


 Issue No.              Description                                         Date Issued
 RF171114C19-5          Original Release                                    Dec. 27, 2017




Report No.: RF171114C19-5                     Page No. 3 / 31       Report Format Version: 6.1.1


1    Certificate of Conformity


            Product: Point of Sale Terminal

              Brand: Verifone

         Test Model: V400c Plus

    Sample Status: Identical Prototype

          Applicant: Verifone, Inc.

          Test Date: Dec. 11, 2017 ~ Dec. 15, 2017

         Standards: 47 CFR FCC Part 15, Subpart C (Section 15.225)
                            47 CFR FCC Part 15, Subpart C (Section 15.215)
                            ANSI C63.10:2013



The above equipment has been tested by Bureau Veritas Consumer Products Services (H.K.) Ltd.,
Taoyuan Branch, and found compliance with the requirement of the above standards. The test record, data
evaluation & Equipment Under Test (EUT) configurations represented herein are true and accurate accounts
of the measurements of the sample’s EMC characteristics under the conditions specified in this report.




      Prepared by :                                                 ,   Date:    Dec. 27, 2017
                                    Evonne Liu / Specialist




     Approved by :                                                  ,   Date:    Dec. 27, 2017
                                Dylan Chiou / Project Engineer




Report No.: RF171114C19-5                         Page No. 4 / 31                    Report Format Version: 6.1.1


                                                                                                                  ooocc



2      Summary of Test Results

                                47 CFR FCC Part 15, Subpart C (Section 15.225, 15.215)

    FCC Clause                       Test Item                    Result                     Remarks
                                                                              Meet the requirement of limit.
       15.207               Conducted emission test                   Pass    Minimum passing margin is —2.75 dB at
                                                                              13.56130 MHz.
                            .                       has                       Meet the requirement of limit.
                    The field strength of any emissions                         N           .      m
      15.225 (a)    within the band 13.553—13.567 MHz                 Pass    Minimum passing margin is —47.74 dB
                                                                              at 13.56 MHz.
                    The field strength of any emissions
      15.225 (b)   within the bands 13.410—13.553 MHz                 Pass    Meet the requirement of limit.
                            and 13.567—13.710 MHz
                    The field strength of any emissions
      15.225 (c)   within the bands 13.110—13.410 MHz                 Pass    Meet the requirement of limit.
                            and 13.710—14.010 MHz
                    The field strength of any emissions                       Meet the requirement of limit.
      15.225 (d)         appearing outside of the                     Pass    Minimum passing margin is —2.6 dB at
                            13.110—14.010 MHz band                            39.6 MHz.
      15.225 (e)            The frequency tolerance                   Pass    Meet the requirement of limit.
      15.215 (c)                  20 dB Bandwidth                     Pass    Meet the requirement of limit.

       15.203                   Antenna Requirement                   Pass    No antenna connector is used.


2.1      Measurement Uncertainty

Where relevant, the following measurement uncertainty levels have been estimated for tests performed on
the EUT as specified in CISPR 16—4—2:



                    Measurement                                         Frequency             Expencl(i(izl;rzf)e apuasy

          Conducted Emissions at mains ports                     150 kHz ~ 30 MHz                      244 dB

                                                                 30 MHz ~ 200 MHz                      2.93 dB
            Radiated Emissions up to 1 GHz
                                                                200 MHz ~1000 MHz                      2.95 dB
                                                                      1 GHz ~ 18 GHz                   2.26 dB
            Radiated Emissions above 1 GHz
                                                                  18 GHz ~ 40 GHz                      1.94 dB



2.2      Modification Record

There were no modifications required for compliance.




Report No.: RF171114G19—5                           Page No. 5 / 31                             Report Format Version: 6.1.1


3     General Information
3.1    General Description of EUT

 Product                     Point of Sale Terminal
 Brand                       Verifone
 Test Model                  V400c Plus
 Status of EUT               Identical Prototype
 Power Supply Rating         11.6 Vdc (adapter)
 Modulation Type             ASK
 Operating Frequency         13.56 MHz
 Antenna Type                Loop Antenna
 Accessory Device            Refer to Note
 Data Cable Supplied         Refer to Note
Note:
1. The EUT contains following accessory devices.
        Product             Brand                     Model                     Description
                                                                   I/P: 100-240 Vac, 50/60 Hz, 0.6 A
       Adapter 1            Verifone           A124-2116167U       O/P: 11.6 Vdc, 1.55 A
                                                                   1.8m non-shielded cable w/o core
                                                                   I/P: 100-240 Vac, 50-60 Hz, 1.0 A
       Adapter 2            Verifone                  VF0102       O/P: 11.6 Vdc, 1.55 A
                                                                   1.8m non-shielded cable w/o core
2. The above EUT information is declared by manufacturer and for more detailed features description,
   please refer to the manufacturer's specifications or user's manual.




Report No.: RF171114C19-5                    Page No. 6 / 31                       Report Format Version: 6.1.1


3.2     Description of Test Modes

One channel was provided to this EUT:
         Channel                Frequency (MHz)
               1                       13.56


3.2.1        Test Mode Applicability and Tested Channel Detail

EUT Configure                                        Applicable To
                                                                                                            Description
    Mode                   RE                  PLC                   FS                EB

         -                  √                   √                    √                   √         -
Where              RE: Radiated Emission                                    PLC: Power Line Conducted Emission
                   FS: Frequency Stability                                  EB: 20 dB Bandwidth measurement




Radiated Emission Test:
   Pre-Scan has been conducted to determine the worst-case mode from all possible combinations between
      available modulations, data rates and antenna ports (if EUT with antenna diversity architecture).
      Following channel(s) was (were) selected for the final test as listed below.
EUT Configure
                         Available Channel              Tested Channel             Modulation Type                 Axis
    Mode

         -                       1                             1                         ASK                         Z



Power Line Conducted Emission Test:
  Pre-Scan has been conducted to determine the worst-case mode from all possible combinations between
      available modulations, data rates and antenna ports (if EUT with antenna diversity architecture).
      Following channel(s) was (were) selected for the final test as listed below.
EUT Configure
                         Available Channel              Tested Channel             Modulation Type                 Axis
    Mode

         -                       1                             1                         ASK                         Z



Frequency Stability:
   This item includes all test value of each mode, but only includes spectrum plot of worst value of each
      mode.
      Pre-Scan has been conducted to determine the worst-case mode from all possible combinations between
      available modulations, data rates and antenna ports (if EUT with antenna diversity architecture).
      Following channel(s) was (were) selected for the final test as listed below.
EUT Configure
                         Available Channel              Tested Channel             Modulation Type                 Axis
    Mode

         -                       1                             1                         ASK                         Z




Report No.: RF171114C19-5                                 Page No. 7 / 31                               Report Format Version: 6.1.1


20 dB Bandwidth:
    This item includes all test value of each mode, but only includes spectrum plot of worst value of each
    mode.
    Pre-Scan has been conducted to determine the worst-case mode from all possible combinations between
    available modulations, data rates and antenna ports (if EUT with antenna diversity architecture).
    Following channel(s) was (were) selected for the final test as listed below.
EUT Configure
                     Available Channel                Tested Channel             Modulation Type              Axis
    Mode

       -                     1                              1                             ASK                   Z



Test Condition:

   Applicable To            Environmental Conditions                      Input Power                  Tested By

           RE                    25 deg. C, 65 % RH                      120 Vac, 60 Hz               Matthew Yang

           FS                    25 deg. C, 65 % RH                         3.8 Vdc                   Matthew Yang

       PLC                       25 deg. C, 65 % RH                      120 Vac, 60 Hz               Jones Chang

           EB                    25 deg. C, 68 % RH                         3.8 Vdc                   Matthew Yang




Report No.: RF171114C19-5                              Page No. 8 / 31                             Report Format Version: 6.1.1


                                                                                                        0
                                                                                                     ommert




3.3     Description of Support Units

The EUT has been tested as an independent unit together with other necessary accessories or support units.


3.3.1    Configuration of System under Test

                                          Q_




                                                $$.
                                                EUT

                                        (Power from AC Adapter)



         *Test Table




3.4     General Description of Applied Standards

The EUT is a RF Product. According to the specifications of the manufacturer, it must comply with the
requirements of the following standards:


FCC Part 15, Subpart C (15.225)
FCC Part 15, Subpart C (15.215)
ANSI C63.10—2013


All test items have been performed and recorded as per the above standards.


NOTE: The EUT has been verified to comply with the requirements of FCC Part 15, Subpart B, Class B (DoC).
         The test report has been issued separately.




Report No.: RF171114G19—5                       Page No. 9 / 31                    Report Format Version: 6.1.1


                                                                                                          &
                                                                                                        ooocc



4        Test Types and Results
4.1      Radiated Emission Measurement
4.1.1      Limits of Radiated Emission Measurement

The field strength of any emissions within the band 13.553—13.567 MHz shall not exceed 15,848
microvolts/meter at 30 meters.
The field strength of any emissions within the bands 13.410—13.553 MHz and 13.567—13.710 MHz shall not
exceed 334 microvolts/meter at 30 meters.
The field strength of any emissions within the bands 13.110—13.410 MHz and 13.710—14.010 MHz shall not
exceed 106 microvolts/meter at 30 meters.
The field strength of any emissions appearing outside of the 13.110—14.010 MHz band shall not exceed the
general radiated emission limits in § 15.209.


              Frequencies                         Field Strength               Measurement Distance
                 (MHz)                          {microvolts/meter)                     {meters)

              0.009 ~ 0.490                        2400/F (kHz)                          300
              0.490 ~1.705                        24000/F (kHz)                           30
              1.705 ~ 30.0                               30                               30
                 30 ~ 88                                100                                3
                88 ~ 216                                150                                3
                216 ~ 960                               200                                3
               Above 960                                500                                3
NOTE:
1. The lower limit shall apply at the transition frequencies.
2.      Emission level (dBuV/m) = 20 log Emission level (uV/m).
3.      For frequencies above 1000 MHz, the field strength limits are based on average detector, however, the
        peak field strength of any emission shall not exceed the maximum permitted average limits, specified
        above by more than 20 dB under any condition of modulation.




Report No.: RF171114G19—5                        Page No. 10 / 31                     Report Format Version: 6.1.1


4.1.2    Test Instruments

        Description &                                                                         Due Date of
                                 Model No.           Serial No.    Date of Calibration
        Manaufacturer                                                                         Calibration
Test Receiver
                                  N9038A           MY51210203          Feb. 17, 2017         Feb. 16, 2018
Agilent
Spectrum Analyzer
                                  N9010A           MY52220314          Nov. 24, 2017         Nov. 23, 2018
Agilent
Spectrum Analyzer
                                   FSL3                  104596        Oct. 11, 2017          Oct. 10, 2018
ROHDE & SCHWARZ
BILOG Antenna
                                 VULB9168             9168-472        Dec. 26, 2016          Dec. 27, 2017
SCHWARZBECK
HORN Antenna                                                          Dec. 12, 2016          Dec. 13, 2017
                               BBHA 9120 D           9120D-969
SCHWARZBECK                                                           Dec. 12, 2017          Dec. 11, 2018
HORN Antenna
                                BBHA 9170             9170-480        Dec. 01, 2017          Nov. 31, 2018
SCHWARZBECK
Fixed Attenuator
                               MDCS18N-10        MDCS18N-10-01         Apr. 17, 2017          Apr. 16, 2018
Mini-Circuits
Loop Antenna                     HLA 6121                45745         May 19, 2017          May 18, 2018
Preamplifier
                                EMC001340                980201        Nov. 01, 2017          Oct. 31, 2018
EMCI
Bluetooth Tester                    CBT                  100946        Jul. 29, 2016          Jul. 28, 2018
Preamplifier
                               EMC 012645                980115        Oct. 20, 2017          Oct. 19, 2018
EMCI
Preamplifier
                               EMC 184045                980116        Oct. 20, 2017          Oct. 19, 2018
EMCI
Preamplifier
                                EMC 330H                 980112        Oct. 13, 2017          Oct. 12, 2018
EMCI
Power Meter
                                 ML2495A              1145013          Mar. 07, 2017         Mar. 06, 2018
Anritsu
Power Sensor
                                 MA2411B              1315050         Aug. 15, 2017          Aug. 14, 2018
Anritsu
RF signal cable                                       309224/4
                              SUCOFLEX 104                             Sep. 11, 2017         Sep. 10, 2018
HUBER+SUHNNER                                         1709074
RF signal cable
                              SUCOFLEX 104            223653/4         Aug. 21, 2017         Aug. 20, 2018
HUBER+SUHNNER
RF Coaxial Cable
                                   8D-FB          Cable-Ch10-01        Oct. 20, 2017          Oct. 19, 2018
Worken
Software                            E3
                                                          NA                NA                      NA
BV ADT                           6.120103
Antenna Tower
                                 MFA-440H                 NA                NA                      NA
MF
Turn Table
                                MFT-201SS                 NA                NA                      NA
MF
Antenna Tower &Turn
Table Controller                 MF-7802                  NA                NA                      NA
MF


Note: 1. The calibration interval of the above test instruments is 12 months and the calibrations are
         traceable to NML/ROC and NIST/USA.
        2. The test was performed in HwaYa Chamber 10.
        3. The horn antenna and preamplifier (model: EMC 184045) are used only for the measurement of
           emission frequency above 1 GHz if tested.
        4. The IC Site Registration No. is IC7450F-10.


Report No.: RF171114C19-5                      Page No. 11 / 31                        Report Format Version: 6.1.1


4.1.3   Test Procedures

a.   The EUT was placed on the top of a rotating table 0.8 meters above the ground at a 3 meters
     semi-anechoic chamber. The table was rotated 360 degrees to determine the position of the highest
     radiation.
b.   The EUT was set 3 meters away from the interference-receiving antenna, which was mounted on the top
     of a variable-height antenna tower.
c.   Height of receiving antenna is varied from one meter to four meters above the ground to determine the
     maximum value of the field strength. Both horizontal and vertical polarizations of the antenna are set to
     make the measurement.
d.   For each suspected emission, the EUT was arranged to its worst case and then the antenna was tuned
     to heights from 1 meter to 4 meters and the rotatable table was turned from 0 degrees to 360 degrees to
     find the maximum reading.
e.   The test-receiver system was set to Peak Detect Function and Specified Bandwidth with Maximum Hold
     Mode.
f.   If the emission level of the EUT in peak mode was lower than the limit specified, then testing could be
     stopped and the peak values of the EUT would be reported. Otherwise the emissions would be re-tested
     one by one using peak, quasi-peak or average method as specified and then reported in a data sheet.


NOTE:
1.   The resolution bandwidth and video bandwidth of test receiver/spectrum analyzer is 120 kHz for
     Quasi-peak detection at frequency below 1 GHz.
2.   The resolution bandwidth of test receiver/spectrum analyzer is 1 MHz and video bandwidth is 3 MHz for
     Peak detection at frequency above 1 GHz.
3.   The resolution bandwidth of test receiver/spectrum analyzer is 1 MHz and the video bandwidth is ≥ 1/T
     (Duty cycle < 98 %) or 10 Hz (Duty cycle > 98 %) for Average detection (AV) at frequency above 1 GHz.
4.   All modes of operation were investigated and the worst-case emissions are reported.


4.1.4   Deviation from Test Standard

No deviation.




Report No.: RF171114C19-5                     Page No. 12 / 31                        Report Format Version: 6.1.1


4.1.5   Test Set Up
Frequency range 9 k ~ 30 MHz:




                                                  3m




Frequency range 30 ~ 1000 MHz:




For the actual test configuration, please refer to the attached file (Test Setup Photo).


4.1.6   EUT Operating Conditions

a. Placed the EUT on the testing table.
b. Set the EUT under transmission condition continuously at specific channel frequency.




Report No.: RF171114C19-5                       Page No. 13 / 31                           Report Format Version: 6.1.1


4.1.7   Test Results

No non-compliance noted:


KDB 937606 OATS and Chamber Correlation Justification

- Base on FCC 15.31 (f) (2): measurements may be performed at a distance closer than that specified in the
regulations; however, an attempt should be made to avoid making measurements in the near field.


- OATs and chamber correlation testing had been performed and chamber measured test result is the worst
case test result.




Report No.: RF171114C19-5                    Page No. 14 / 31                       Report Format Version: 6.1.1


EUT Test Condition                                                                            Measurement Detail
Channel                              Channel 1                                                Frequency Range                                       13.553 ~ 13.567MHz
Input Power                          120Vac, 60Hz                                             Detector Function                                     Quasi-Peak
Environmental Conditions 25 deg. C, 70% RH                                                    Tested By                                             Matthew Yang

                              Antenna Polarity & Test Distance: Loop Antenna Open At 3m
                      Emission                                                                        Antenna                    Table                  Raw         Correction
          Freq.                                 Limit                    Margin
 No.                    Level                                                                          Height                   Angle                   Value        Factor
         (MHz)                                (dBuV/m)                    (dB)
                      (dBuV/m)                                                                          (m)                    (Degree)                (dBuV)        (dB/m)
  1      *13.56       76.26 PK               124.00 QP                   -47.74                         1.00                      355                   55.76         20.50

Remarks:          1. Emission level(dBuV/m)=Raw Value(dBuV) + Correction Factor(dB/m)
                  2. Correction Factor(dB/m) = Antenna Factor (dB/m) + Cable Factor (dB)
                  3. The other emission levels were very low against the limit.
                  4. Margin value = Emission level – Limit value.
                  5. Above limits have been translated by the formula

The measured field strength was extrapolated to distance 30 meters, using the formula that the limit of field
strength varies as the inverse distance square (40dB per decade of distance)
Example:
13.56MHz = 15848uV/m                     30m
             = 84dBuV/m                  30m
                                2
             = 84+20log(30/3)            3m
             = 124dBuV/m

                                                                                      * RBW   10    kHz   Marker   1    [T1    ]
                                                                                      * VBW   30    kHz                76.26       dBµV/m
                               Ref   90   dBµV/m            * Att   10   dB            SWT    2.5    ms       13.559760000              MHz

                               90


                                                                                                                                               A
                               80                                                 1

                       1 PK
                       VIEW
                               70


                                                                                                                                              TDF
                               60


                                                                                                                                              PS
                               50



                               40


                                                                                                                                              3DB
                               30                                                                                                             AC




                               20



                               10



                               0


                               -10

                               Center     13.56   MHz                         8   kHz/                                  Span       80   kHz




                       Date: 11.DEC.2017                14:56:22




Report No.: RF171114C19-5                                            Page No. 15 / 31                                                                 Report Format Version: 6.1.1


EUT Test Condition                                                                            Measurement Detail
Channel                              Channel 1                                                Frequency Range                                       13.553 ~ 13.567MHz
Input Power                          120Vac, 60Hz                                             Detector Function                                     Quasi-Peak
Environmental Conditions 25 deg. C, 70% RH                                                    Tested By                                             Matthew Yang

                              Antenna Polarity & Test Distance: Loop Antenna Close At 3m
                      Emission                                                                        Antenna                    Table                  Raw         Correction
          Freq.                                 Limit                    Margin
 No.                    Level                                                                          Height                   Angle                   Value        Factor
         (MHz)                                (dBuV/m)                    (dB)
                      (dBuV/m)                                                                          (m)                    (Degree)                (dBuV)        (dB/m)
  1      *13.56       71.52 PK               124.00 QP                   -52.48                         1.00                      265                   51.02         20.50

Remarks:          1. Emission level(dBuV/m)=Raw Value(dBuV) + Correction Factor(dB/m)
                  2. Correction Factor(dB/m) = Antenna Factor (dB/m) + Cable Factor (dB)
                  3. The other emission levels were very low against the limit.
                  4. Margin value = Emission level – Limit value.
                  5. Above limits have been translated by the formula

The measured field strength was extrapolated to distance 30 meters, using the formula that the limit of field
strength varies as the inverse distance square (40dB per decade of distance)
Example:
13.56MHz = 15848uV/m                     30m
             = 84dBuV/m                  30m
                                2
             = 84+20log(30/3)            3m
             = 124dBuV/m

                                                                                      * RBW   10    kHz   Marker   1    [T1    ]
                                                                                      * VBW   30    kHz                71.52       dBµV/m
                               Ref   90   dBµV/m            * Att   10   dB            SWT    2.5    ms       13.560005000              MHz

                               90


                                                                                                                                               A
                               80

                       1 PK                                                       1
                       VIEW
                               70


                                                                                                                                              TDF
                               60


                                                                                                                                              PS
                               50



                               40


                                                                                                                                              3DB
                               30                                                                                                             AC




                               20



                               10



                               0


                               -10

                               Center     13.56   MHz                         8   kHz/                                  Span       80   kHz




                       Date: 11.DEC.2017                15:10:05




Report No.: RF171114C19-5                                            Page No. 16 / 31                                                                 Report Format Version: 6.1.1


                                                                                                                                        0
                                                                                                                                     ommert




EUT Test Condition                                                       Measurement Detail
Channel                            Channel 1                             Frequency Range                    Below 3OMHz

Input Power                        120Vac, 60Hz                          Detector Function                  Quasi—Peak
Environmental Conditions 25 deg. C, 70% RH                               Tested By                          Matthew Yang


                            Antenna Polarity & Test Distance: Loop Antenna Open At 3m
                        Emission                w                   .               Antenna       Table              Raw         Correction
          Freq.                                Limit          Margin                   .
 No.      (MHz)          Level               (dBu¥/m)           (dB)                Height       Angle              Value           Factor
                       (dBuV/im)                                                      (m)       (Degres)           (dBuV)          (dB/m)
  1       0.97         40.31 QP               67.88           —27.57                 1.00         302               20.05           20.26
  2       2.29         44.53 QP               69.54           —25.01                 1.00         146               24.22           20.31
  3       6.97         36.46 QP               69.54           —33.08                 1.00         102               16.03           20.43
  4       14.88        36.76 QP               69.54           —32.78                 1.00         295               16.23           20.53
  5       16.44        36.28 QP               69.54           —33.26                 1.00          12               15.71           20.57
  6       28.56        35.59 QP               69.54           —33.95                 1.00         147               15.03           20.56


Remarks:
                 1. Emission Level(dBuV/m) = Raw Value(dBuV) + Correction Factor(dB/m)
              2. Correction Factor(dB/m) = Antenna Factor(dB/m) + Cable Factor(dB)
              3. The other emission levels were very low against the limit.
              4. Margin value = Emission Level — Limit value

                             Level
                            (dBu¥im)
                              80

                              80



                              60
                                         2
                                     +                 3                 4005
                              40



                              20



                               0

                             si       i          i    i     1      1     1    1      1     1     i     1     1
                               maoe 2500       some 7500 10.000 12500 15000 17500 20000 22500 25000 27500 30.000
                                                                 Frequency (Mitz)




Report No.: RF171114G19—5                                    Page No. 17 / 31                                      Report Format Version: 6.1.1


                                                                                                                          0
                                                                                                                       ommert




EUT Test Condition                                                 Measurement Detail
Channel                             Channel 1                      Frequency Range                 Below 3OMHz

Input Power                         120Vac, 60Hz                   Detector Function               Quasi—Peak
Environmental Conditions 25 deg. C, 70% RH                         Tested By                       Matthew Yang


                            Antenna Polarity & Test Distance: Loop Antenna Close At 3m
                      Emission               m                 .            Antenna        Table       Raw         Correction
          Freq.                             Limit         Margin               .
 No.      MH            Level              dBuV/im         (dB)             Height         Angle       Value          Factor
          (MHz)       (aBuvim)             CBY®                               (m)      (Degree)       (dBuV)         (dB/m)
  1        2.23       49.52 QP              69.54         —20.02             1.00           12         29.22           20.3
  2        4.99       39.09 QP              69.54         —30.45             1.00          207          18.6          20.49
  3        7.27       40.13 QP              69.54         —29.41             1.00          171         19.71          20.42
  4       16.08       44.22 QP              69.54         —25.92             1.00          318         23.65          20.57
  5       20.04       41.84 QP              69.54          —27.7             1.00          271         21.42          20.42
  6       24.84       36.41 QP              69.54         —33.13             1.00          349         15.79          20.62

Remarks:
               1. Emission Level(dBuV/m) = Raw Value(dBuV) + Correction Factor(dB/m)
               2. Correction Factor(dB/m) = Antenna Factor(dB/m) + Cable Factor(dB)
               3. The other emission levels were very low against the limit.
               4. Margin value = Emission Level — Limit value

                             Level
                            (dBuvim)
                              90

                              80




                              hid      1
                                              :      3                f            $   a
                              «0



                              20



                               0


                             eeaieainainnes      mapeereerele
                                         Frequency (Miz)




Report No.: RF171114G19—5                                Page No. 18 / 31                            Report Format Version: 6.1.1


                                                                                                                                         ooocc




EUT Test Condition                                                       Measurement Detail
Channel                           Channel 1                              Frequency Range                        Below 3OMHz

Input Power                       120Vac, 60Hz                           Detector Function                      Quasi—Peak
Environmental Conditions 25 deg. C, 70% RH                               Tested By                              Matthew Yang


                            Antenna Polarity & Test Distance: Loop Antenna Open At 3m
                      Emission               m                       .             Antenna          Table                Raw         Correction
          Freq.                             Limit             Margin                  .
 No.      MH            Level             (dBu¥/im)             (dB)               Height           Angle               Value           Factor
          (MHz)       (dBuV/im)              4                                       (m)          (Degree)             (dBuV)          (dB/m)
  1       27.12       35.12 QP              69.54              —34.42               1.00              32                14.46           20.66


Remarks:
               1. Emission Level(dBuV/m) = Raw Value(dBuV) + Correction Factor(dB/m)
               2. Correction Factor(dB/m) = Antenna Factor(dB/m) + Cable Factor(dB)
               3. The other emission levels were very low against the limit.
               4. Margin value = Emission Level — Limit value

                             Level
                            (dBu¥im)
                             so
                             so




                              o—
                                 i       i    i        i      i      1     i      1      1     1     i     i      1
                              oa0s     2ooo 5000    7.500. 10.000 12500 15.000 17.500 20000 22500 25000 27.500 30000
                                                                 Frequency (Miz)




Report No.: RF171114G19—5                                    Page No. 19 / 31                                          Report Format Version: 6.1.1


EUT Test Condition                                         Measurement Detail
Channel                        Channel 1                   Frequency Range            Below 30MHz
Input Power                    120Vac, 60Hz                Detector Function          Quasi-Peak
Environmental Conditions 25 deg. C, 70% RH                 Tested By                  Matthew Yang

                            Antenna Polarity & Test Distance: Loop Antenna Close At 3m
                      Emission                                  Antenna      Table        Raw          Correction
          Freq.                       Limit       Margin
 No.                    Level                                    Height     Angle         Value         Factor
         (MHz)                      (dBuV/m)       (dB)
                      (dBuV/m)                                    (m)      (Degree)      (dBuV)         (dB/m)
  1      27.12        38.89 QP        69.54       -30.65          1.00         247        18.23           20.66


Remarks:
              1. Emission Level(dBuV/m) = Raw Value(dBuV) + Correction Factor(dB/m)
              2. Correction Factor(dB/m) = Antenna Factor(dB/m) + Cable Factor(dB)
              3. The other emission levels were very low against the limit.
              4. Margin value = Emission Level – Limit value




Report No.: RF171114C19-5                        Page No. 20 / 31                        Report Format Version: 6.1.1


EUT Test Condition                                          Measurement Detail
Channel                      Channel 1                      Frequency Range            Below 1000MHz
Input Power                  120Vac, 60Hz                   Detector Function          Quasi-Peak
Environmental Conditions 25 deg. C, 70% RH                  Tested By                  Matthew Yang

                                 Antenna Polarity & Test Distance: Horizontal At 3m
                      Emission                                  Antenna       Table        Raw         Correction
          Freq.                        Limit       Margin
 No.                    Level                                    Height      Angle         Value        Factor
         (MHz)                       (dBuV/m)       (dB)
                      (dBuV/m)                                     (m)      (Degree)      (dBuV)        (dB/m)
  1       66.77         34 QP           40           -6          1.99 H        127         48.9          -14.9
  2       121.1         27 QP          43.5        -16.5         1.50 H        64          42.7          -15.7
  3      293.79        37.2 QP          46          -8.8         1.00 H        259         49.3          -12.1
  4      381.11        33.7 QP          46         -12.3         1.00 H        297         44.1          -10.4
  5      747.85        35.4 QP          46         -10.6         1.00 H        343         37.8           -2.4
  6       899.2        40.1 QP          46          -5.9         1.00 H        108          40            0.1
                                  Antenna Polarity & Test Distance: Vertical At 3m
                      Emission                                  Antenna       Table        Raw         Correction
          Freq.                        Limit       Margin
 No.                    Level                                    Height      Angle         Value        Factor
         (MHz)                       (dBuV/m)       (dB)
                      (dBuV/m)                                     (m)      (Degree)      (dBuV)        (dB/m)
  1        39.6        37.4 QP          40          -2.6         1.00 V        355         52.1          -14.7
  2       66.77        36.9 QP          40          -3.1         1.00 V        188         51.8          -14.9
  3      293.79        31.2 QP          46         -14.8         1.49 V        13          43.3          -12.1
  4      359.77        28.5 QP          46         -17.5         1.49 V        217         39.3          -10.8
  5      792.48        31.7 QP          46         -14.3         1.49 V        13          33.3           -1.6
  6      897.26        35.1 QP          46         -10.9         1.49 V        181          35            0.1


Remarks:
              1. Emission Level(dBuV/m) = Raw Value(dBuV) + Correction Factor(dB/m)
              2. Correction Factor(dB/m) = Antenna Factor(dB/m) + Cable Factor(dB)
              3. The other emission levels were very low against the limit.
              4. Margin value = Emission Level – Limit value




Report No.: RF171114C19-5                        Page No. 21 / 31                        Report Format Version: 6.1.1


4.2      Conducted Emission Measurement
4.2.1      Limits of Conducted Emission Measurement

                                                             Conducted Limit (dBuV)
        Frequency (MHz)
                                               Quasi-peak                                 Average
             0.15 - 0.5                           66 - 56                                 56 - 46
             0.50 - 5.0                             56                                      46
             5.0 - 30.0                             60                                      50
Note:
1. The lower limit shall apply at the transition frequencies.
2. The limit decreases in line with the logarithm of the frequency in the range of 0.15 to 0.50 MHz.
3. All emanations from a class A/B digital device or system, including any network of conductors and
      apparatus connected thereto, shall not exceed the level of field strengths specified above.


4.2.2      Test Instruments

         Description &                                                      Date Of              Due Date Of
                                  Model No.              Serial No.
         Manufacturer                                                      Calibration           Calibration
Test Receiver
                                     ESCI                 100613          Nov. 21, 2016          Nov. 20, 2017
ROHDE & SCHWARZ
RF signal cable (with
10dB PAD)                            5D-FB          Cable-cond1-01        Sep. 05, 2017          Sep. 04, 2018
Woken
LISN/AMN
ROHDE & SCHWARZ                    ESH3-Z5            835239/001          Mar. 10, 2017          Mar. 09, 2018
(EUT)
LISN/AMN
ROHDE & SCHWARZ                     ENV216                101196          Apr. 20, 2017          Apr. 19, 2018
(Peripheral)
Software                        BV ADT_Cond_
                                                            NA                  NA                     NA
ADT                                V7.3.7.3

Note: 1. The calibration interval of the above test instruments is 12 months and the calibrations are traceable
            to NML/ROC and NIST/USA.
         2. The test was performed in HwaYa Shielded Room 1.
         3. The VCCI Site Registration No. is C-2040.




Report No.: RF171114C19-5                        Page No. 22 / 31                         Report Format Version: 6.1.1


                                                                                                               ooocc



4.2.3      Test Procedures
a.      The EUT was placed 0.4 meters from the conducting wall of the shielded room with EUT being
        connected to the power mains through a line impedance stabilization network (LISN). Other support units
        were connected to the power mains through another LISN. The two LISNs provide 50 ohm/50 uH of
        coupling impedance for the measuring instrument.
        Both lines of the power mains connected to the EUT were checked for maximum conducted interference.
        The frequency range from 150 kHz to 30 MHz was searched. Emission levels under (Limit — 20 dB) was
        not recorded.

NOTE: The resolution bandwidth and video bandwidth of test receiver is 9 kHz for quasi—peak detection (QP)
          and average detection (AV) at frequency 0.15 MHz — 30 MHz.


4.2.4      Deviation from Test Standard
No deviation.


4.2.5       Test Setup


                                       Vertical Ground
                                       Reference Plane                         /Test Receiver
                        ~at——ie                                                       L____]
                                                                                       c o o o
                         40cm          EUT                                      **~~! 0 a a o


                                                            80cm
                         |LISN
                                  L1               L1                  N       L1
                                                                                                 tH

                                                            \
                                                                       Horizontal
                                                                                    Ground
                                                                       Reference Plane

                          Note: 1.Support units were connected to second LISN.
                                 2.Both of LISNs (AMN) are 80 cm from EUT and at least 80
                                  from other units and other metal planes


For the actual test configuration, please refer to the attached file (Test Setup Photo).


4.2.6      EUT Operating Conditions

a.   Placed the EUT on the testing table.
b.   Set the EUT under transmission condition continuously at specific channel frequency.




Report No.: RF171114G19—5                           Page No. 23 / 31                         Report Format Version: 6.1.1


                                                                                                                      3)
                                                                                                                  ommert




4.2.7    Test Results
                                                             Detector Function &           .
                                                                    .              Quasi—Peak (QP) /
Frequency Range             150kHz ~ 30MHz                   Resolution
                                                             Bandwidth             Average (AV), 9kHz

                                                             Environmental           s
Input Power                 120Vac, 60Hz                     Conditions            25°C, 75%RH

Tested by                   Jones Chang                      Test Date             2017/12/4


                                              Phase Of Power : Line (L)
         Frequency      |Correction|   Reading Value       Emission Level           Limit                   Margin
 No                         Factor          (dBuV)              (dBuV)             (dBuV)                    (dB)
          (MHz)              (dB)       Q.P.       AV.      Q.P.      AV.      Q.P.       AV.           Q.P.       AV.
  1      0.15782            10.45      30.24     13.14     40.69     23.59    65.58     55.58          —24.89    —31.99
  2      0.18122            10.45      27.15     10.39     37.60     20.84    64.43     54.48          —26.83    —33.59
  3      0.22820            10.46      20.95      8.33     31.41     18.79    62.51     52.51          —31.10    —33.72
  4      0.52130            10.51      20.77     12.41     31.28     22.92    56.00     46.00          —24.72    —23.08
  5      6.95340            10.79      13.23      7.94     24.02     18.73    60.00     50.00          —35.98    —31.27
  6      13.56130           11.11      36.37     36.14     4748      47.25    60.00     50.00          1252       —2.75
Remarks:
          1. Q.P. and AV. are abbreviations of quasi—peak and average individually.
          2. The emission levels of other frequencies were very low against the limit.
         3. Margin value = Emission level — Limit value
         4. Correction factor = Insertion loss + Cable loss
         5. Emission Level = Correction Factor + Reading Value
                            #f8
                              &
                              8
                              d
                              8
                              60B
                              8
                              B
                              s
                              a9




                                                   1ho                                   sale
                              &




                                                                                          mie




Report No.: RF171114G19—5                          Page No. 24 / 31                             Report Format Version: 6.1.1


                                                                                                                          ommert
                                                                                                                          [vexiras)]



                                                            Detector Function &                     .
Frequency Range             150kHz ~ 30MHz                  Resolultion                   S:;i;e(i{(vg(}:lzl-/lz
                                                            Bandwidth                                       "
Input Power                 120Vac, 60Hz                    Eg‘r’]'é‘i’fi”omnima'          25°C, 75%RH
Tested by                   Jones Chang                     Test Date                     2017/12/4


                                           Phase Of Power : Neutral (N)
         Frequency     |Correction|   Reading Value       Emission Level                     Limit                  Margin
 No                         Factor         (dBuV)             (dBuV)                       (dBuV)                     (dB)
          (MHz)              (dB)      Q.P.       AV.      QP.      AV.                Q.P.       AV.            QP.        AV.
  1      0.15000            10.20     31.40     13.28     41.60    23.48              66.00     56.00           —24.40    —32.52
  2      0.18519            10.22     25.64      8.18     35.86    1840               64.25     54.25           —28.39    —35.85
  3      0.31422            10.23     13.73      2.57     23.96    12.80              59.86     49.86           —35.90    —37.06
  4      0.52130            10.24     21.12     13.14     31.36    23.38              56.00     46.00           —24.64    —22.62
  5      6.95340            10.54     13.42      7.88     23.96    1842               60.00     50.00           —36.04    —31.58
  6      13.56130           10.81     85.97     35.71     46.78    46.52              60.00     50.00           —13.22     —3.48
Remarks:
          1. Q.P. and AV. are abbreviations of quasi—peak and average individually.
          2. The emission levels of other frequencies were very low against the limit.
         3. Margin value = Emission level — Limit value
         4. Correction factor = Insertion loss + Cable loss
         5. Emission Level = Correction Factor + Reading Value


                                                                                   io Trace _
                                                                                   ar timit |.=—
                                                                                   Cay Limit |.o—




Report No.: RF171114G19—5                         Page No. 25 / 31                                      Report Format Version: 6.1.1


4.3      Frequency Stability
4.3.1      Limits of Frequency Stability Measurement

The frequency tolerance of the carrier signal shall be maintained within +/- 0.01 % of the operating frequency
over a temperature variation of –20 degrees to 50 degrees C at normal supply voltage, and for a variation in
the primary supply voltage from 85 % to 115% of the rated supply voltage at a temperature of 20 degrees C.


4.3.2      Test Setup

                            Temperature
                            Chamber

      Spectrum Analyzer




                     DC Power Supply




4.3.3      Test Instruments

Refer to section 4.1.2 to get information of above instrument.


4.3.4      Test Procedure

a. The EUT was placed inside the environmental test chamber and powered by nominal DC voltage.
b. Turned the EUT on and coupled its output to a spectrum analyzer.
c. Turned the EUT off and set the chamber to the highest temperature specified.
d. Allowed sufficient time (approximately 30 min) for the temperature of the chamber to stabilize then turned
      the EUT on and measured the operating frequency after 2, 5, and 10 minutes.
e. Repeated step 2 and 3 with the temperature chamber set to the lowest temperature.
f.    The test chamber was allowed to stabilize at +20 degree C for a minimum of 30 minutes. The supply
      voltage was then adjusted on the EUT from 85 % to 115 % and the frequency record.


4.3.5      Deviation fromTest Standard

No deviation.


4.3.6      EUT Operating Conditions

a. Placed the EUT on the testing table.
b. Set the EUT under transmission condition continuously at specific channel frequency.




Report No.: RF171114C19-5                      Page No. 26 / 31                       Report Format Version: 6.1.1


                                                                                                                      &
4.3.7    Test Result

                                           Frequency Stability Versus Temperature
                            0 Minute                  2 Minute                   5 Minute                 10 Minute

Temp. SP::;; Measured Frequ_ency Measured Frequ_ency Measured Frequ_ency Measured Frequ_ency
 (C)   (Vde) Frequency   Drift   Frequency   Drift   Frequency   Drift   Frequency   Drift

                    (MHz)              %         (MHz)           %         (MHz)            %        (MHz)            %
  50      11.6   |13.560075)     0.00055       |13.560055|   0.00041     |13.560061|]   0.00045   |13.560078|     0.00058
  40      11.6   |13.559978| —0.00016          |13.559989| —0.00008 |13.559995| —0.00004          |13.559982] —0.00013
  30      11.6   |13.559947| —0.00039          |13.559934] —0.00049 |13.559954] —0.00034          |13.559955| —0.00033
  20      11.6   |13.560054]     0.00040       |13.560051]   0.00038     |13.560064]    0.00047   |13.560056|     0.00041
  10      11.6   |13.560016)     0.00012       |13.560019]   0.00014     13.56003       0.00022   |13.560018]     0.00013
   0      11.6   |13.560053|     0.00039       |13.560062]   0.00046     |13.560064]    0.00047   |13.560071|     0.00052
 —10      11.6   113.559945] —0.00041          |13.559941|   —0.00044 |13.559939] —0.00045        |13.559926| —0.00055
 —20      11.6    13.56004       0.00029       |13.560046]   0.00034     |13.560019|    0.00014   |13.560035|     0.00026


                                             Frequency Stability Versus Voltage

                            0 Minute                  2 Minute                   5 Minute                 10 Minute

Temp. SP::;; Measured Frequ_ency Measured Frequ_ency Measured Frequ_ency Measured Frequ_ency
 (C)   (Vde) Frequency   Drift   Frequency   Drift   Frequency   Drift   Frequency   Drift

                    (MHz)              %         (MHz)           %         (MHz)            %        (MHz)            %
         13.34 |13.560051|       0.00038       |13.560051]   0.00038     |13.560069]    0.00051   |13.560054]     0.00040
  20      11.6   |13.560054]     0.00040       |13.560051]   0.00038     |13.560064]    0.00047   |13.560056|     0.00041
         9.86    |13.560051]     0.00038       13.56005      0.00037     |13.560066]    0.00049   |13.560052]     0.00038




Report No.: RF171114G19—5                             Page No. 27 / 31                            Report Format Version: 6.1.1


4.4     20 dB Bandwidth
4.4.1    Limits of 20 dB Bandwidth Measurement

The 20 dB bandwidth shall be specified in operating frequency band.


4.4.2    Test Setup

Refer to section 4.1.5.


4.4.3    Test Instruments

Refer to section 4.1.2 to get information of above instrument.


4.4.4    Test Procedures

The bandwidth of the fundamental frequency was measured by spectrum analyzer with 1 kHz RBW and 3 kHz
VBW. The 20 dB bandwidth is defined as the total spectrum the power of which is higher than peak power
minus 20 dB.


4.4.5    Deviation from Test Standard

No deviation.


4.4.6    EUT Operating Conditions

a. Placed the EUT on the testing table.
b. Set the EUT under transmission condition continuously at specific channel frequency.




Report No.: RF171114C19-5                      Page No. 28 / 31                    Report Format Version: 6.1.1


4.4.7      Test Results

                                                                             Operating Frequency Band
   20 dBc Point (Low)                     20 dBc Point (High)                                                                          Pass / Fail
                                                                                       (MHz)
        13.553 MHz                                  13.567 MHz                          13.553~13.567                                        Pass


                                                          Spectrum Plot Of Value
                                                                       * RBW     1    kHz   Delta    1       [T1    ]
                                                                       * VBW     3    kHz                           0.28         dB
            Ref    90   dBµV/m                 * Att    10   dB          SWT     20    ms           2.560000000                  kHz

             90                                                                             Marker       1    [T1       ]
                                                                                                             56.70          dBµV/m
                                                                                                13.558560000                     MHz    A
             80
                        D1   76.15      dB*                                                 Marker       2    [T1       ]
    1 AP
                                                                                                              8.60          dBµV/m
    VIEW
             70                                                                                 13.553000000                     MHz
                                                                                            Marker       3    [T1       ]
                                                                                                              7.13          dBµV/m     TDF
             60                                              1               1
                                                                                                13.567000000                     MHz
                             D2   56.15       dB*
                                                                                                                                       PS
             50



             40


                                                                                                                                       3DB
             30                                                                                                                        AC




             20


                             2
             10                                                                                               3



             0
                                                                                                             F2
                             F1
             -10

            Center      13.56     MHz                             2   kHz/                                    Span          20   kHz




   Date: 15.DEC.2017                    10:17:17




Report No.: RF171114C19-5                                         Page No. 29 / 31                                               Report Format Version: 6.1.1


5    Pictures of Test Arrangements

Please refer to the attached file (Test Setup Photo).




Report No.: RF171114C19-5                      Page No. 30 / 31   Report Format Version: 6.1.1


Appendix – Information on the Testing Laboratories


We, Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch, were founded in 1988 to
provide our best service in EMC, Radio, Telecom and Safety consultation. Our laboratories are FCC
recognized accredited test firms and accredited according to ISO/IEC 17025.

If you have any comments, please feel free to contact us at the following:

Linko EMC/RF Lab                                       Hsin Chu EMC/RF/Telecom Lab
Tel: 886-2-26052180                                    Tel: 886-3-6668565
Fax: 886-2-26051924                                    Fax: 886-3-6668323


Hwa Ya EMC/RF/Safety
Tel: 886-3-3183232
Fax: 886-3-3270892


Email: service.adt@tw.bureauveritas.com
Web Site: www.bureauveritas-adt.com

The address and road map of all our labs can be found in our web site also.



--- END ---




Report No.: RF171114C19-5                      Page No. 31 / 31                  Report Format Version: 6.1.1



Document Created: 2018-01-04 17:53:12
Document Modified: 2018-01-04 17:53:12

© 2019 FCC.report