MPE declaration

FCC ID: AZPTMSS2-24G

RF Exposure Info

Download: PDF
FCCID_853025

                            Declaration of Compliance

FCC ID: AZPTMSS2—24G
Product Name: Radio Control
Model No: TMSS2—2.4G

Futaba Corporation declares that the product described above has been evaluated and found to
comply with the RF exposure limits for humans, as specified based on ANSUV/FCC
recommendation. Based on safety distance 20cm, the antenna gain is 1.64dBi, and the power
output is 54.325mW, the power density is 0.01575mW/cm*2.

RF Exposure Calculations:
S = (P * G) / (4* z *r2) orr=   \/(P *G)/(4 *z *S)

Where S = Power Density in mW/icm*2
       P = 17.35dBm = 54.325mW
       G = 1.64dBi = 1.458 Numerical
       r =20cm

S = 54.325*1.458 / 4*z * 2042 = 0.01575mWicm*2




Sincerely Yours,


    Todbchic Yamazaehi—
Toshihiro Yamaguchi
Radio Control Equipment Group Manager
Futaba Corporation



Document Created: 2007-10-06 23:48:13
Document Modified: 2007-10-06 23:48:13