RF Exposure Info MPE

FCC ID: AZPR7003SB-24G

RF Exposure Info

Download: PDF
FCCID_1832913

                       Declaration of Compliance

FCC ID: AZPR7003SB-24G

Product Name: Radio Control

Model No: R7003SB

Audix Technology (Company Name). declares that the product described above has been
evaluated and found to comply with the RF exposure limits for humans, as specified
based on ANSI/FCC recommendation. Based on safety distance 20cm, the antenna gain
is -5.1dBi, and the power output is 19.95mW, the power density is 0.0012mW/cm^2.

RF Exposure Calculations:
S = (P * G) / (4* π * r^2) or r =   (P * G) / (4 * π * S)

Where S = Power Density in mW/cm^2
P = 13dBm = 19.95mW
G = -5.1dBi = 0.31 Numerical
r = 20cm
S = 19.95*0.31 / 4*π* 20^2 =6.18/5026.55= 0.0012mW/cm^2

Limit MPE < 1mW/cm^2

Result: Passed



Document Created: 2012-11-07 17:21:13
Document Modified: 2012-11-07 17:21:13

© 2025 FCC.report