Test Report Charts

FCC ID: AZPFP-T3FR-72

Test Report

Download: PDF
FCCID_170319

                                   Radiated Power Test 30 MHz - 300 MHz
                                    according to FCC Part 95 Subpart C/E
Model:                                                                  Mode:
T2(3)FR-AM                                                              - TX mode f = 72.550 MHz
Serial no.:
--                                                                      - EUT in vertical position - antenna vertical

Applicant:
Futaba Corporation
Test site:
Semi anechoic room, cabin no. 3
Tested on:
Test distance 3 meters
Horizontal Polarization
Date of test:                       Operator:
07/18/2001                          T. Eberl
Test performed:                     File name:
automatically

Detector:                                                               List of values:
Peak                                                                    Selected by hand

dBm                                                                     Limit1: FCC §95.639b3          Transducer: Substitution (H)
 0



-10



-20



-30



-40



-50



-60



-70



-80



-90



-100
   30                                                                   100                                                     300
                                                                                                                                MHz
Result:                                                                 Project file:
Limit kept                                                              55503-10420                           Page 36 of 59 Pages
                Senton GmbH / EMI/EMC Laboratories / Aeussere Fruehlingsstrasse 45 / D-94315 Straubing / Tel. +49 9421 55220


                                   Radiated Power Test 30 MHz - 300 MHz
                                    according to FCC Part 95 Subpart C/E
Model:                                                                  Mode:
T2(3)FR-AM                                                              - TX mode f = 72.550 MHz
Serial no.:
--                                                                      - EUT in vertical position - antenna vertical

Applicant:
Futaba Corporation
Test site:
Semi anechoic room, cabin no. 3
Tested on:
Test distance 3 meters
Horizontal Polarization
Date of test:                       Operator:
07/18/2001                          T. Eberl
Test performed:                     File name:
automatically

Detector:                                                               List of values:
Peak                                                                    Selected by hand

     Frequency                 Reading               Correction factor                    Value         Limit              Limit
        MHz                     dBm                        dB                             dBm           dBm              exceeded
           72.55                 -23.0                      18.7                           -4.3        -27.3                   *
          145.10                 -78.5                      23.9                          -54.6        -27.3
          217.65                 -91.4                      30.4                          -61.0        -27.3




Result:                                                                 Project file:
Limit kept                                                              55503-10420                             Page 37 of 59 Pages
                Senton GmbH / EMI/EMC Laboratories / Aeussere Fruehlingsstrasse 45 / D-94315 Straubing / Tel. +49 9421 55220


                                   Radiated Power Test 30 MHz - 300 MHz
                                    according to FCC Part 95 Subpart C/E
Model:                                                                  Mode:
T2(3)FR-AM                                                              - TX mode f = 72.550 MHz
Serial no.:
--                                                                      - EUT in horizontal position - antenna horizontal

Applicant:
Futaba Corporation
Test site:
Semi anechoic room, cabin no. 3
Tested on:
Test distance 3 meters
Horizontal Polarization
Date of test:                       Operator:
07/18/2001                          T. Eberl
Test performed:                     File name:
automatically

Detector:                                                               List of values:
Peak                                                                    Selected by hand

dBm                                                                     Limit1: FCC §95.639b3          Transducer: Substitution (H)
 0



-10



-20



-30



-40



-50



-60



-70



-80



-90



-100
   30                                                                   100                                                     300
                                                                                                                                MHz
Result:                                                                 Project file:
Limit kept                                                              55503-10420                           Page 38 of 59 Pages
                Senton GmbH / EMI/EMC Laboratories / Aeussere Fruehlingsstrasse 45 / D-94315 Straubing / Tel. +49 9421 55220


                                   Radiated Power Test 30 MHz - 300 MHz
                                    according to FCC Part 95 Subpart C/E
Model:                                                                  Mode:
T2(3)FR-AM                                                              - TX mode f = 72.550 MHz
Serial no.:
--                                                                      - EUT in horizontal position - antenna horizontal

Applicant:
Futaba Corporation
Test site:
Semi anechoic room, cabin no. 3
Tested on:
Test distance 3 meters
Horizontal Polarization
Date of test:                       Operator:
07/18/2001                          T. Eberl
Test performed:                     File name:
automatically

Detector:                                                               List of values:
Peak                                                                    Selected by hand

     Frequency                 Reading               Correction factor                    Value         Limit              Limit
        MHz                     dBm                        dB                             dBm           dBm              exceeded
           72.55                  -2.4                      18.7                           16.3        -27.3                   *
          145.10                 -58.5                      23.9                          -34.6        -27.3
          217.65                 -93.4                      30.4                          -63.0        -27.3
          290.20                 -92.0                      34.0                          -58.0        -27.3




Result:                                                                 Project file:
Limit kept                                                              55503-10420                             Page 39 of 59 Pages
                Senton GmbH / EMI/EMC Laboratories / Aeussere Fruehlingsstrasse 45 / D-94315 Straubing / Tel. +49 9421 55220


                                   Radiated Power Test 30 MHz - 300 MHz
                                    according to FCC Part 95 Subpart C/E
Model:                                                                  Mode:
T2(3) FR                                                                - TX mode f = 72.550 Mhz
Serial no.:
--                                                                      - EUT in horizontal position- antenna horizontal
                                                                         ( right side on table )
Applicant:
Futaba corporation
Test site:
Semi anechoic room, cabin no. 3
Tested on:
Test distance 3 meters
Horizontal Polarization
Date of test:                       Operator:
07/18/2001                          T. Eberl
Test performed:                     File name:
automatically

Detector:                                                               List of values:
Peak                                                                    Selected by hand

dBm                                                                     Limit1: FCC §95.639b3          Transducer: Substitution (H)
 0



-10



-20



-30



-40



-50



-60



-70



-80



-90



-100
   30                                                                   100                                                     300
                                                                                                                                MHz
Result:                                                                 Project file:
Limit kept                                                              55503-10420                           Page 40 of 59 Pages
                Senton GmbH / EMI/EMC Laboratories / Aeussere Fruehlingsstrasse 45 / D-94315 Straubing / Tel. +49 9421 55220


                                   Radiated Power Test 30 MHz - 300 MHz
                                    according to FCC Part 95 Subpart C/E
Model:                                                                  Mode:
T2(3) FR                                                                - TX mode f = 72.550 Mhz
Serial no.:
--                                                                      - EUT in horizontal position- antenna horizontal
                                                                         ( right side on table )
Applicant:
Futaba corporation
Test site:
Semi anechoic room, cabin no. 3
Tested on:
Test distance 3 meters
Horizontal Polarization
Date of test:                       Operator:
07/18/2001                          T. Eberl
Test performed:                     File name:
automatically

Detector:                                                               List of values:
Peak                                                                    Selected by hand

     Frequency                 Reading               Correction factor                    Value         Limit              Limit
        MHz                     dBm                        dB                             dBm           dBm              exceeded
           72.55                  -1.1                      18.7                           17.6        -27.3                   *
          145.10                 -57.9                      23.9                          -34.0        -27.3
          217.65                 -83.4                      30.4                          -53.0        -27.3
          290.20                 -93.0                      34.0                          -59.0        -27.3




Result:                                                                 Project file:
Limit kept                                                              55503-10420                             Page 41 of 59 Pages
                Senton GmbH / EMI/EMC Laboratories / Aeussere Fruehlingsstrasse 45 / D-94315 Straubing / Tel. +49 9421 55220


                                   Radiated Power Test 30 MHz - 300 MHz
                                    according to FCC Part 95 Subpart C/E
Model:                                                                  Mode:
T2(3)FR-AM                                                              - TX mode f = 72.550 MHz
Serial no.:
--                                                                      - EUT in vertical position - antenna vertical

Applicant:
Futaba Corporation
Test site:
Semi anechoic room, cabin no. 3
Tested on:
Test distance 3 metres
Vertical Polarization
Date of test:                       Operator:
07/18/2001                          T. Eberl
Test performed:                     File name:
automatically

Detector:                                                               List of values:
Peak                                                                    Selected by hand

dBm                                                                     Limit1: FCC §95.639b3          Transducer: Substitution (V)
 0



-10



-20



-30



-40



-50



-60



-70



-80



-90



-100
   30                                                                   100                                                     300
                                                                                                                                MHz
Result:                                                                 Project file:
Limit kept                                                              55503-10420                           Page 42 of 59 Pages
                Senton GmbH / EMI/EMC Laboratories / Aeussere Fruehlingsstrasse 45 / D-94315 Straubing / Tel. +49 9421 55220


                                   Radiated Power Test 30 MHz - 300 MHz
                                    according to FCC Part 95 Subpart C/E
Model:                                                                  Mode:
T2(3)FR-AM                                                              - TX mode f = 72.550 MHz
Serial no.:
--                                                                      - EUT in vertical position - antenna vertical

Applicant:
Futaba Corporation
Test site:
Semi anechoic room, cabin no. 3
Tested on:
Test distance 3 metres
Vertical Polarization
Date of test:                       Operator:
07/18/2001                          T. Eberl
Test performed:                     File name:
automatically

Detector:                                                               List of values:
Peak                                                                    Selected by hand

     Frequency                 Reading               Correction factor                    Value         Limit              Limit
        MHz                     dBm                        dB                             dBm           dBm              exceeded
           72.55                  -6.4                      25.7                           19.3        -27.3                   *
          145.10                 -64.7                      29.4                          -35.3        -27.3
          217.65                 -88.7                      31.7                          -57.0        -27.3
          290.20                 -95.9                      35.9                          -60.0        -27.3




Result:                                                                 Project file:
Limit kept                                                              55503-10420                             Page 43 of 59 Pages
                Senton GmbH / EMI/EMC Laboratories / Aeussere Fruehlingsstrasse 45 / D-94315 Straubing / Tel. +49 9421 55220


                                   Radiated Power Test 30 MHz - 300 MHz
                                    according to FCC Part 95 Subpart C/E
Model:                                                                  Mode:
T2(3)FR-AM                                                              - TX mode f = 72.550 MHz
Serial no.:
--                                                                      - EUT in horizontal position - antenna horizontal

Applicant:
Futaba Corporation
Test site:
Semi anechoic room, cabin no. 3
Tested on:
Test distance 3 metres
Vertical Polarization
Date of test:                       Operator:
07/18/2001                          T. Eberl
Test performed:                     File name:
automatically

Detector:                                                               List of values:
Peak                                                                    Selected by hand

dBm                                                                     Limit1: FCC §95.639b3          Transducer: Substitution (V)
 0



-10



-20



-30



-40



-50



-60



-70



-80



-90



-100
   30                                                                   100                                                     300
                                                                                                                                MHz
Result:                                                                 Project file:
Limit kept                                                              55503-10420                           Page 44 of 59 Pages
                Senton GmbH / EMI/EMC Laboratories / Aeussere Fruehlingsstrasse 45 / D-94315 Straubing / Tel. +49 9421 55220


                                   Radiated Power Test 30 MHz - 300 MHz
                                    according to FCC Part 95 Subpart C/E
Model:                                                                  Mode:
T2(3)FR-AM                                                              - TX mode f = 72.550 MHz
Serial no.:
--                                                                      - EUT in horizontal position - antenna horizontal

Applicant:
Futaba Corporation
Test site:
Semi anechoic room, cabin no. 3
Tested on:
Test distance 3 metres
Vertical Polarization
Date of test:                       Operator:
07/18/2001                          T. Eberl
Test performed:                     File name:
automatically

Detector:                                                               List of values:
Peak                                                                    Selected by hand

     Frequency                 Reading               Correction factor                    Value         Limit              Limit
        MHz                     dBm                        dB                             dBm           dBm              exceeded
           72.55                  -7.5                      25.7                           18.2        -27.3                   *
          145.10                 -68.1                      29.4                          -38.7        -27.3
          290.20                 -95.4                      35.9                          -59.5        -27.3




Result:                                                                 Project file:
Limit kept                                                              55503-10420                             Page 45 of 59 Pages
                Senton GmbH / EMI/EMC Laboratories / Aeussere Fruehlingsstrasse 45 / D-94315 Straubing / Tel. +49 9421 55220


                                   Radiated Power Test 30 MHz - 300 MHz
                                    according to FCC Part 95 Subpart C/E
Model:                                                                  Mode:
T2(3) FR                                                                - TX mode f = 72.550 Mhz
Serial no.:
--                                                                      - EUT in horizontal position- antenna horizontal
                                                                         ( right side on table )
Applicant:
Futaba corporation
Test site:
Semi anechoic room, cabin no. 3
Tested on:
Test distance 3 metres
Vertical Polarization
Date of test:                       Operator:
07/18/2001                          T. Eberl
Test performed:                     File name:
automatically

Detector:                                                               List of values:
Peak                                                                    Selected by hand

dBm                                                                     Limit1: FCC §95.639b3          Transducer: Substitution (V)
 0



-10



-20



-30



-40



-50



-60



-70



-80



-90



-100
   30                                                                   100                                                     300
                                                                                                                                MHz
Result:                                                                 Project file:
Limit kept                                                              55503-10420                           Page 46 of 59 Pages
                Senton GmbH / EMI/EMC Laboratories / Aeussere Fruehlingsstrasse 45 / D-94315 Straubing / Tel. +49 9421 55220


                                   Radiated Power Test 30 MHz - 300 MHz
                                    according to FCC Part 95 Subpart C/E
Model:                                                                  Mode:
T2(3) FR                                                                - TX mode f = 72.550 Mhz
Serial no.:
--                                                                      - EUT in horizontal position- antenna horizontal
                                                                         ( right side on table )
Applicant:
Futaba corporation
Test site:
Semi anechoic room, cabin no. 3
Tested on:
Test distance 3 metres
Vertical Polarization
Date of test:                       Operator:
07/18/2001                          T. Eberl
Test performed:                     File name:
automatically

Detector:                                                               List of values:
Peak                                                                    Selected by hand

     Frequency                 Reading               Correction factor                    Value         Limit              Limit
        MHz                     dBm                        dB                             dBm           dBm              exceeded
           72.55                  -7.6                      25.7                           18.1        -27.3                   *
          145.10                 -70.3                      29.4                          -40.9        -27.3
          217.65                 -91.7                      31.7                          -60.0        -27.3
          290.20                 -96.9                      35.9                          -61.0        -27.3




Result:                                                                 Project file:
Limit kept                                                              55503-10420                             Page 47 of 59 Pages
                Senton GmbH / EMI/EMC Laboratories / Aeussere Fruehlingsstrasse 45 / D-94315 Straubing / Tel. +49 9421 55220


                                    Radiated Power Test 295 MHz - 1 GHz
                                    according to FCC Part 95 Subpart C/E
Model:                                                                  Mode:
T2(3)FR-AM                                                              - TX mode f = 72.550 MHz
Serial no.:
--                                                                      - EUT in vertical position - antenna vertical

Applicant:
Futaba Corporation
Test site:
Semi anechoic room, cabin no. 3
Tested on:
Test distance 3 meters
Horizontal Polarization
Date of test:                       Operator:
07/18/2001                          T. Eberl
Test performed:                     File name:
automatically

Detector:                                                               List of values:
Peak                                                                    Selected by hand

dBm                                                                    Limit1: FCC §95.639b3           Transducer: Substitution (H)
 0



-10



-20



-30



-40



-50



-60



-70



-80



-90



-100
   295                                                                                                                          1000
                                                                                                                                MHz
Result:                                                                 Project file:
Limit kept                                                              55503-10420                           Page 48 of 59 Pages
                Senton GmbH / EMI/EMC Laboratories / Aeussere Fruehlingsstrasse 45 / D-94315 Straubing / Tel. +49 9421 55220


                                    Radiated Power Test 295 MHz - 1 GHz
                                    according to FCC Part 95 Subpart C/E
Model:                                                                  Mode:
T2(3)FR-AM                                                              - TX mode f = 72.550 MHz
Serial no.:
--                                                                      - EUT in vertical position - antenna vertical

Applicant:
Futaba Corporation
Test site:
Semi anechoic room, cabin no. 3
Tested on:
Test distance 3 meters
Horizontal Polarization
Date of test:                       Operator:
07/18/2001                          T. Eberl
Test performed:                     File name:
automatically

Detector:                                                               List of values:
Peak                                                                    Selected by hand

     Frequency                 Reading               Correction factor                    Value         Limit              Limit
        MHz                     dBm                        dB                             dBm           dBm              exceeded
          362.75                 -89.6                      32.6                          -57.0        -27.3
          435.30                 -91.0                      34.0                          -57.0        -27.3
          507.85                 -84.8                      36.3                          -48.5        -27.3
          580.40                 -90.5                      36.5                          -54.0        -27.3
          652.95                 -82.7                      37.7                          -45.0        -27.3
          725.50                 -81.5                      39.5                          -42.0        -27.3
          798.05                 -88.7                      40.7                          -48.0        -27.3




Result:                                                                 Project file:
Limit kept                                                              55503-10420                             Page 49 of 59 Pages
                Senton GmbH / EMI/EMC Laboratories / Aeussere Fruehlingsstrasse 45 / D-94315 Straubing / Tel. +49 9421 55220


                                    Radiated Power Test 295 MHz - 1 GHz
                                    according to FCC Part 95 Subpart C/E
Model:                                                                  Mode:
T2(3)FR-AM                                                              - TX mode f = 72.550 MHz
Serial no.:
--                                                                      - EUT in horizontal position - antenna horizontal

Applicant:
Futaba Corporation
Test site:
Semi anechoic room, cabin no. 3
Tested on:
Test distance 3 meters
Horizontal Polarization
Date of test:                       Operator:
07/18/2001                          T. Eberl
Test performed:                     File name:
automatically

Detector:                                                               List of values:
Peak                                                                    Selected by hand

dBm                                                                    Limit1: FCC §95.639b3           Transducer: Substitution (H)
 0



-10



-20



-30



-40



-50



-60



-70



-80



-90



-100
   295                                                                                                                          1000
                                                                                                                                MHz
Result:                                                                 Project file:
Limit kept                                                              55503-10420                           Page 50 of 59 Pages
                Senton GmbH / EMI/EMC Laboratories / Aeussere Fruehlingsstrasse 45 / D-94315 Straubing / Tel. +49 9421 55220


                                    Radiated Power Test 295 MHz - 1 GHz
                                    according to FCC Part 95 Subpart C/E
Model:                                                                  Mode:
T2(3)FR-AM                                                              - TX mode f = 72.550 MHz
Serial no.:
--                                                                      - EUT in horizontal position - antenna horizontal

Applicant:
Futaba Corporation
Test site:
Semi anechoic room, cabin no. 3
Tested on:
Test distance 3 meters
Horizontal Polarization
Date of test:                       Operator:
07/18/2001                          T. Eberl
Test performed:                     File name:
automatically

Detector:                                                               List of values:
Peak                                                                    Selected by hand

     Frequency                 Reading               Correction factor                    Value         Limit              Limit
        MHz                     dBm                        dB                             dBm           dBm              exceeded
          362.75                 -82.6                      32.6                          -50.0        -27.3
          435.30                 -89.0                      34.0                          -55.0        -27.3
          507.85                 -84.3                      36.3                          -48.0        -27.3
          580.40                 -87.5                      36.5                          -51.0        -27.3
          652.95                 -85.7                      37.7                          -48.0        -27.3
          725.50                 -83.5                      39.5                          -44.0        -27.3
          798.05                 -90.7                      40.7                          -50.0        -27.3




Result:                                                                 Project file:
Limit kept                                                              55503-10420                             Page 51 of 59 Pages
                Senton GmbH / EMI/EMC Laboratories / Aeussere Fruehlingsstrasse 45 / D-94315 Straubing / Tel. +49 9421 55220


                                    Radiated Power Test 295 MHz - 1 GHz
                                    according to FCC Part 95 Subpart C/E
Model:                                                                  Mode:
T2(3) FR                                                                - TX mode f = 72.550 Mhz
Serial no.:
--                                                                      - EUT in horizontal position- antenna horizontal
                                                                         ( right side on table )
Applicant:
Futaba corporation
Test site:
Semi anechoic room, cabin no. 3
Tested on:
Test distance 3 meters
Horizontal Polarization
Date of test:                       Operator:
07/18/2001                          T. Eberl
Test performed:                     File name:
automatically

Detector:                                                               List of values:
Peak                                                                    Selected by hand

dBm                                                                    Limit1: FCC §95.639b3           Transducer: Substitution (H)
 0



-10



-20



-30



-40



-50



-60



-70



-80



-90



-100
   295                                                                                                                          1000
                                                                                                                                MHz
Result:                                                                 Project file:
Limit kept                                                              55503-10420                           Page 52 of 59 Pages
                Senton GmbH / EMI/EMC Laboratories / Aeussere Fruehlingsstrasse 45 / D-94315 Straubing / Tel. +49 9421 55220


                                    Radiated Power Test 295 MHz - 1 GHz
                                    according to FCC Part 95 Subpart C/E
Model:                                                                  Mode:
T2(3) FR                                                                - TX mode f = 72.550 Mhz
Serial no.:
--                                                                      - EUT in horizontal position- antenna horizontal
                                                                         ( right side on table )
Applicant:
Futaba corporation
Test site:
Semi anechoic room, cabin no. 3
Tested on:
Test distance 3 meters
Horizontal Polarization
Date of test:                       Operator:
07/18/2001                          T. Eberl
Test performed:                     File name:
automatically

Detector:                                                               List of values:
Peak                                                                    Selected by hand

     Frequency                 Reading               Correction factor                    Value         Limit              Limit
        MHz                     dBm                        dB                             dBm           dBm              exceeded
          362.75                 -84.6                      32.6                          -52.0        -27.3
          435.30                 -86.0                      34.0                          -52.0        -27.3
          507.85                 -90.3                      36.3                          -54.0        -27.3
          580.40                 -95.5                      36.5                          -59.0        -27.3
          652.95                 -80.7                      37.7                          -43.0        -27.3
          725.50                 -88.5                      39.5                          -49.0        -27.3
          798.05                 -96.7                      40.7                          -56.0        -27.3
          943.15                 -98.8                      42.8                          -56.0        -27.3




Result:                                                                 Project file:
Limit kept                                                              55503-10420                             Page 53 of 59 Pages
                Senton GmbH / EMI/EMC Laboratories / Aeussere Fruehlingsstrasse 45 / D-94315 Straubing / Tel. +49 9421 55220


                                    Radiated Power Test 295 MHz - 1 GHz
                                    according to FCC Part 95 Subpart C/E
Model:                                                                  Mode:
T2(3)FR-AM                                                              - TX mode f = 72.550 MHz
Serial no.:
--                                                                      - EUT in vertical position - antenna vertical

Applicant:
Futaba Corporation
Test site:
Semi anechoic room, cabin no. 3
Tested on:
Test distance 3 metres
Vertical Polarization
Date of test:                       Operator:
07/18/2001                          T. Eberl
Test performed:                     File name:
automatically

Detector:                                                               List of values:
Peak                                                                    Selected by hand

dBm                                                                     Limit1: FCC §95.639b3          Transducer: Substitution (V)
 0



-10



-20



-30



-40



-50



-60



-70



-80



-90



-100
   295                                                                                                                          1000
                                                                                                                                MHz
Result:                                                                 Project file:
Limit kept                                                              55503-10420                           Page 54 of 59 Pages
                Senton GmbH / EMI/EMC Laboratories / Aeussere Fruehlingsstrasse 45 / D-94315 Straubing / Tel. +49 9421 55220


                                    Radiated Power Test 295 MHz - 1 GHz
                                    according to FCC Part 95 Subpart C/E
Model:                                                                  Mode:
T2(3)FR-AM                                                              - TX mode f = 72.550 MHz
Serial no.:
--                                                                      - EUT in vertical position - antenna vertical

Applicant:
Futaba Corporation
Test site:
Semi anechoic room, cabin no. 3
Tested on:
Test distance 3 metres
Vertical Polarization
Date of test:                       Operator:
07/18/2001                          T. Eberl
Test performed:                     File name:
automatically

Detector:                                                               List of values:
Peak                                                                    Selected by hand

     Frequency                 Reading               Correction factor                    Value         Limit              Limit
        MHz                     dBm                        dB                             dBm           dBm              exceeded
          362.75                 -85.0                      32.0                          -53.0        -27.3
          435.30                 -89.3                      35.3                          -54.0        -27.3
          507.85                 -89.6                      37.6                          -52.0        -27.3
          580.40                 -93.2                      39.2                          -54.0        -27.3
          652.95                 -86.4                      40.4                          -46.0        -27.3
          725.50                 -88.8                      40.8                          -48.0        -27.3




Result:                                                                 Project file:
Limit kept                                                              55503-10420                             Page 55 of 59 Pages
                Senton GmbH / EMI/EMC Laboratories / Aeussere Fruehlingsstrasse 45 / D-94315 Straubing / Tel. +49 9421 55220


                                    Radiated Power Test 295 MHz - 1 GHz
                                    according to FCC Part 95 Subpart C/E
Model:                                                                  Mode:
T2(3)FR-AM                                                              - TX mode f = 72.550 MHz
Serial no.:
--                                                                      - EUT in horizontal position - antenna horizontal

Applicant:
Futaba Corporation
Test site:
Semi anechoic room, cabin no. 3
Tested on:
Test distance 3 metres
Vertical Polarization
Date of test:                       Operator:
07/18/2001                          T. Eberl
Test performed:                     File name:
automatically

Detector:                                                               List of values:
Peak                                                                    Selected by hand

dBm                                                                     Limit1: FCC §95.639b3          Transducer: Substitution (V)
 0



-10



-20



-30



-40



-50



-60



-70



-80



-90



-100
   295                                                                                                                          1000
                                                                                                                                MHz
Result:                                                                 Project file:
Limit kept                                                              55503-10420                           Page 56 of 59 Pages
                Senton GmbH / EMI/EMC Laboratories / Aeussere Fruehlingsstrasse 45 / D-94315 Straubing / Tel. +49 9421 55220


                                    Radiated Power Test 295 MHz - 1 GHz
                                    according to FCC Part 95 Subpart C/E
Model:                                                                  Mode:
T2(3)FR-AM                                                              - TX mode f = 72.550 MHz
Serial no.:
--                                                                      - EUT in horizontal position - antenna horizontal

Applicant:
Futaba Corporation
Test site:
Semi anechoic room, cabin no. 3
Tested on:
Test distance 3 metres
Vertical Polarization
Date of test:                       Operator:
07/18/2001                          T. Eberl
Test performed:                     File name:
automatically

Detector:                                                               List of values:
Peak                                                                    Selected by hand

     Frequency                 Reading               Correction factor                    Value         Limit              Limit
        MHz                     dBm                        dB                             dBm           dBm              exceeded
          362.75                 -90.0                      32.0                          -58.0        -27.3
          435.30                 -96.3                      35.3                          -61.0        -27.3
          507.85                 -92.6                      37.6                          -55.0        -27.3
          580.40                 -93.2                      39.2                          -54.0        -27.3
          652.95                 -91.4                      40.4                          -51.0        -27.3
          725.50                 -92.8                      40.8                          -52.0        -27.3




Result:                                                                 Project file:
Limit kept                                                              55503-10420                             Page 57 of 59 Pages
                Senton GmbH / EMI/EMC Laboratories / Aeussere Fruehlingsstrasse 45 / D-94315 Straubing / Tel. +49 9421 55220


                                    Radiated Power Test 295 MHz - 1 GHz
                                    according to FCC Part 95 Subpart C/E
Model:                                                                  Mode:
T2(3) FR                                                                - TX mode f = 72.550 Mhz
Serial no.:
--                                                                      - EUT in horizontal position- antenna horizontal
                                                                         ( right side on table )
Applicant:
Futaba corporation
Test site:
Semi anechoic room, cabin no. 3
Tested on:
Test distance 3 metres
Vertical Polarization
Date of test:                       Operator:
07/18/2001                          T. Eberl
Test performed:                     File name:
automatically

Detector:                                                               List of values:
Peak                                                                    Selected by hand

dBm                                                                     Limit1: FCC §95.639b3          Transducer: Substitution (V)
 0



-10



-20



-30



-40



-50



-60



-70



-80



-90



-100
   295                                                                                                                          1000
                                                                                                                                MHz
Result:                                                                 Project file:
Limit kept                                                              55503-10420                           Page 58 of 59 Pages
                Senton GmbH / EMI/EMC Laboratories / Aeussere Fruehlingsstrasse 45 / D-94315 Straubing / Tel. +49 9421 55220


                                    Radiated Power Test 295 MHz - 1 GHz
                                    according to FCC Part 95 Subpart C/E
Model:                                                                  Mode:
T2(3) FR                                                                - TX mode f = 72.550 Mhz
Serial no.:
--                                                                      - EUT in horizontal position- antenna horizontal
                                                                         ( right side on table )
Applicant:
Futaba corporation
Test site:
Semi anechoic room, cabin no. 3
Tested on:
Test distance 3 metres
Vertical Polarization
Date of test:                       Operator:
07/18/2001                          T. Eberl
Test performed:                     File name:
automatically

Detector:                                                               List of values:
Peak                                                                    Selected by hand

     Frequency                 Reading               Correction factor                    Value         Limit              Limit
        MHz                     dBm                        dB                             dBm           dBm              exceeded
          362.75                 -86.0                      32.0                          -54.0        -27.3
          435.30                 -87.3                      35.3                          -52.0        -27.3
          507.85                 -86.6                      37.6                          -49.0        -27.3
          580.40                 -95.2                      39.2                          -56.0        -27.3
          652.95                 -81.4                      40.4                          -41.0        -27.3
          725.50                 -80.8                      40.8                          -40.0        -27.3
          798.05                 -93.2                      42.2                          -51.0        -27.3




Result:                                                                 Project file:
Limit kept                                                              55503-10420                             Page 59 of 59 Pages
                Senton GmbH / EMI/EMC Laboratories / Aeussere Fruehlingsstrasse 45 / D-94315 Straubing / Tel. +49 9421 55220



Document Created: 2001-08-15 14:16:51
Document Modified: 2001-08-15 14:16:51

© 2025 FCC.report