Test Report - DFS Client

FCC ID: AZ492FT7124

Test Report

Download: PDF
FCCID_4472232

Report Templatee Document Number
R                          N       : FCD-00107                                                  Reportt ID: 14913-R
                                                                                                                  RF-00062
R
Report Templatee Revision Num
                            mber :    Rev.. C                                                      FC
                                                                                                    CC ID: AZ4922FT7124
                                                                                                        IC: 109U-92FT7124




                                                                                                            SAMM No.0825
                                                                                                                 N


   MOTOROL    LA PENANG ADV. COMM     M. LABORAT
                                               TORY                         FCC Part 15
                                                                                     1 Subpart E, 15.407
   Motorola Soolutions Malaysia Sdn Bhd,,
   Innoplex, Pllot 2A Medan
                          n Bayan Lepass,                                   Report Revvision              : Rev.A
   Mukim 12 S.W.D,
              S       11900 Bayan Lepas,,                                   Report ID                     : 14913-RF-00062
   Penang, Maalaysia.                                                                 quest ID
                                                                            Service Req                   : 14913


   Date/s Testeed                     :     1-Jul-2019
   Manufacturrer/Location             :     M
                                            Motorola  Soluutions Malaysiaa Sdn Bhd
                                      :     P 2 Bayan Lepas
                                            Plot          L      Technopplex, 11900 Bayyan Lepas,
   Manufacturrer Address
                                            P
                                            Penang, Malayysia
   Requestor                          :     T
                                            TANG,   GARY  Y
   Product Typpe                      :     M
                                            Mobile
   Tested Basic Function              :     T
                                            Transmit / Recceive
   External Model Name (PM MN)        :     A
                                            APX6500
   Sales Modell Number (HVVIN)        :     M
                                            M25URS9PW   W1BN
   Frequency Band
              B                       :     5
                                            5180-5320MH  Hz; 5500-5825M  MHz
   Rated/Max RF Output Po  ower       :     8
                                            802.11a, 802.111 n20 - 12.58mmW / 15.84mWW
   Applicant Name
             N                              M
                                            Motorola  Soluutions Inc
   FCC Registtrations                 :     4
                                            461337
   ISED Registtrations                :     109AK
   Firmware Version
             V        (FVIN
                          N)          :     D
                                            D19.71.02


   The equipm
            ment was tested
                          d to the standaard(s) listed below
                                                       b     with thee following ressult :

   -         FC
              CC Part 15 Subpart                                                  PASS
             E 15.407
                1
             ISEED RSS-247, Issue 2
             February 2017 Section
                           S
             6.33

   This report shall
               s              produced withoout written approval from an officially desiggnated represenntative of the Motorola
                     not be rep                                                                                         M
   Penang Adv. Comm. Laboratory. The resultsr      and statements containned in this repoort pertain onlyy to the device((s)
   evaluated.

               P
               Prepared By:                                                        Apprroved By:


               ______________
                            ______________                                         ___________________________
                G Boon Teong
                Gan                                                                Vincent Foong Chuen Kit
                T
                Technician                                                            uty Technical Manager
                                                                                   Depu



       NOTE: Accredited
             A          testt.                                                                                 Page 1 of 10


Report Template Document Number : FCD-0107                                                                                                  Report ID: 14913-RF-00062
Report Template Revision Number :  Rev. C                                                                                                      FCC ID: AZ492FT7124
                                                                                                                                                   IC: 109U-92FT7124


TABLE OF CONTENTS

1. Introduction and Overview .................................................................................................................................................... 3
2. Test Laboratory Status ........................................................................................................................................................... 3
3. Test Environmental Conditions ............................................................................................................................................. 3
   3.1. Temperature and Humidity ............................................................................................................................................ 3
   3.2. Tolerance .......................................................................................................................................................................... 3
   3.3. Measurement Uncertainty .............................................................................................................................................. 3
4. Test Results Summary ............................................................................................................................................................ 3
5. Technical Data of Device Under Test .................................................................................................................................... 4
   5.1. Operating Frequency Bands and Mode of EUT ........................................................................................................... 4
   5.2. List of antennas and their corresponding gains ............................................................................................................ 4
   5.3. Modifications and deviation from standard .................................................................................................................. 4
   5.4. EUT Maximum Output Power ....................................................................................................................................... 4
   5.5. Channel loading messages or sequences ........................................................................................................................ 4
   5.6. Transmit Power Control (TPC)...................................................................................................................................... 5
   5.7. Time required for master or client device to complete power cycle ............................................................................ 5
   5.8. System Architecture ........................................................................................................................................................ 5
   5.9. Master device identification ............................................................................................................................................ 5
6. Test setup and list of equipment ............................................................................................................................................ 5
   6.1. Setup block diagram ........................................................................................................................................................ 5
   6.2. List of Equipment ............................................................................................................................................................ 6
   6.3. Test Setup Photos............................................................................................................................................................. 6
7. Test Requirements .................................................................................................................................................................. 7
   7.1. DFS Requirements / Limits............................................................................................................................................. 7
   7.2. DFS Detection Threshold ................................................................................................................................................ 7
8. Test Procedure and Test Data ............................................................................................................................................... 8
   8.1. Test Method...................................................................................................................................................................... 8
   8.2. Test Data........................................................................................................................................................................... 8




REVISION HISTORY

        Revision History                                     Description                                        Date                                         Originator
             Rev. A                                          Initial report                                 13-AUG-2019                                     Vincent Foong




        NOTE: Accredited test.                                                                                                                                    Page 2 of 10


Report Template Document Number : FCD-0107                                                      Report ID: 14913-RF-00062
Report Template Revision Number :  Rev. C                                                          FCC ID: AZ492FT7124
                                                                                                       IC: 109U-92FT7124


1. Introduction and Overview
       This report details the utilization, technical data of device under test, test equipment, and test results of the
       measurements performed at the Motorola Penang Advanced Communication Laboratory in accordance to the
       standards specified on page 1.

       This test report is only valid in its original form.

       The test results herein refer only to the tested sample. Motorola Penang Advanced Communication Laboratory is not
       responsible for any generalizations or conclusions drawn from these test results and concerning further samples.


2. Test Laboratory Status
       Motorola Penang Advanced Communication Laboratory is an ISO/IEC17025:2005 accredited laboratory. The
       laboratory was accredited by SAMM, with SAMM Cert No #0825


3. Test Environmental Conditions
   3.1. Temperature and Humidity
                    Ambient
                                            Rel. Air Humidity
                  Temperature
                  15 °C to 35 °C            20 %RH to 75%RH
   3.2. Tolerance


           Chamber Temperature Tolerance                Chamber Humidity Tolerance
                          ± 0.3 °c                                  ±3%

   3.3. Measurement Uncertainty
       The measurement uncertainty represents an expanded uncertainty expressed at approximately the 95% confidence
       level using a coverage factor of k=1.96


4. Test Results Summary
       The table below summarizes the test results for the test completed. For detailed test data, refer to section 7.


        Section                                Test Parameters                                          Results
         7.1.1          FCC Part 15.407 / RSS‐247 Non Occupancy Period                                   PASS
         7.1.2          FCC Part 15.407 / RSS‐247 Channel Move Time                                      PASS
         7.1.3          FCC Part 15.407 / RSS‐247 Channel Closing Transmission Time                      PASS

   NOTE:
   NA  Not Applicable




    NOTE: Accredited test.                                                                                     Page 3 of 10


Report Template Document Number : FCD-0107                                                  Report ID: 14913-RF-00062
Report Template Revision Number :  Rev. C                                                      FCC ID: AZ492FT7124
                                                                                                   IC: 109U-92FT7124


5. Technical Data of Device Under Test
   5.1. Operating Frequency Bands and Mode of EUT

                                                                Operating Frequency Range
                 Operational Mode
                                                           5250‐5350MHz          5470‐5725MHz
         Client without radar detection and ad
                                                                    Yes                               Yes
                     hoc function



   5.2. List of antennas and their corresponding gains

         Antenna #                   Type                  Frequency Range                       Max Gain (dBi)
                 1                WiFi Antenna                 4900‐5900MHz                           5.15


   5.3. Modifications and deviation from standard
       There is no deviation between the test carried out compared to the standard test method

   5.4. EUT Maximum Output Power
   802.11a

                                                                                                     Max EIRP
      Antenna #            Frequency Range                 Output Power (dBm)                     including duty
                                                                                                 cycle correction
             1                5250‐5725MHz                            11.215                          16.585
             1                5470‐5725MHz                            10.017                          15.387


   802.11n (20MHz)

                                                                                                     Max EIRP
      Antenna #            Frequency Range                 Output Power (dBm)                     including duty
                                                                                                 cycle correction
             1                5250‐5725MHz                            11.286                          16.566
             1                5470‐5725MHz                            10.057                          15.337



   5.5. Channel loading messages or sequences
                 Channel loading was achieved by using iPerf software to control throughput.




    NOTE: Accredited test.                                                                              Page 4 of 10


Report Template Document Number : FCD-0107                                                Report ID: 14913-RF-00062
Report Template Revision Number :  Rev. C                                                    FCC ID: AZ492FT7124
                                                                                                 IC: 109U-92FT7124


   5.6. Transmit Power Control (TPC)
               U-NII devices operating in the 5.25-5.35GHz band and the 5.47-5.725GHz band shall employ a TPC
               mechanism. The U-NII device is required to have the capability to operate at least 6dB below the EIRP value
               of 30dBm. A TPC mechanism is not required for systems with an EIRP of less than 500mW.

               Maximum EIRP for this device is 16.585 dBm which is 45.55 mW, therefore TPC is not required.

   5.7. Time required for master or client device to complete power cycle
               The master device took 1 minute and 15 seconds to complete its power cycle. The client device does not have
               radar detection and therefore its power on time is not applicable.

   5.8. System Architecture
               The EUT utilizes IP based system architecture


   5.9. Master device identification
               The DFS compliant master device used for testing was a Linksys WRT3200ACM with serial number
               19810625700081, and FCC ID Q87-WRT3200ACM and IC ID 3839A-WRT3200ACM



6. Test setup and list of equipment
    6.1. Setup block diagram




    NOTE: Accredited test.                                                                              Page 5 of 10


Report Template Document Number : FCD-0107                               Report ID: 14913-RF-00062
Report Template Revision Number :  Rev. C                                   FCC ID: AZ492FT7124
                                                                                IC: 109U-92FT7124


    6.2. List of Equipment
                                                                       Calibration   Calibration Due
              Description                    Model #   Serial Number
                                                                          Date            Date
 SIGNAL GENERATOR                            SMU200A      104134        10‐Jul‐18       10‐Jul‐21
 OPEN SWITCH & CONTROL UNIT                   OSP120      101256         4‐Jul‐18        4‐Jul‐19
 SIGNAL GENERATOR                            SMB100A      177677        11‐Jul‐17       11‐Jul‐20
 SIGNAL ANALYZER                               FSV        101515       24‐Mar‐17       24‐Mar‐20
 POWER SUPPLY ( 0‐20V / 0‐120A,
                                              6031A    US38311166      30‐Aug‐18       30‐Aug‐19
 1000W )
 VECTOR SIGNAL GENERATOR                     SMB100A      261962       30‐Apr‐18       30‐Apr‐21




    6.3. Test Setup Photos




    NOTE: Accredited test.                                                           Page 6 of 10


Report Template Document Number : FCD-0107                                                   Report ID: 14913-RF-00062
Report Template Revision Number :  Rev. C                                                       FCC ID: AZ492FT7124
                                                                                                    IC: 109U-92FT7124


7. Test Requirements
    7.1. DFS Requirements / Limits

                 Requirement                                                      Limit
              Channel Move Time                                           10 seconds
        Channel Closing Transmission Time             200ms + an aggregate 60ms over following 10 seconds
             Non‐Occupancy Period                                         30 minutes


    7.2. DFS Detection Threshold
               The calibrated conducted DFS detection threshold level was set at -63 dBm. This level exceeds the
               specification for the stipulated detection level of -64dBm and ensures there is margin to the limit to ensure
               successful detection.




    NOTE: Accredited test.                                                                                  Page 7 of 10


Report Template Document Number : FCD-0107                                                  Report ID: 14913-RF-00062
Report Template Revision Number :  Rev. C                                                      FCC ID: AZ492FT7124
                                                                                                   IC: 109U-92FT7124


8. Test Procedure and Test Data

    8.1. Test Method
               DFS testing was performed using the conducted test methods defined in 905462 D02 UNII DFS Compliance
               Procedures New Rules v02. The devices was a client only device without radar detection capability. The
               Rohde & Schwarz TS8997 test system in conjunction with WMS32 software was used for the automation of
               the testing.


    8.2. Test Data




       The resulting plot data was extracted and post processed, giving a duty cycle of 26.6%.




    NOTE: Accredited test.                                                                              Page 8 of 10


Report Template Document Number : FCD-0107                                                   Report ID: 14913-RF-00062
Report Template Revision Number :  Rev. C                                                       FCC ID: AZ492FT7124
                                                                                                    IC: 109U-92FT7124


                DFS Detection Threshold




                Peak of -45.24dBm, with losses at combiners factoring antenna gain to be 15.81dB, therefore level going into
                antenna port is -61.05dBm which exceeds threshold level of -64dBm for successful detection.


                Channel Move and Closing Time




         Channel Closing and Channel Move Time
         Detailed Results
         DUT Frequency Radar                                     No of pulses Tx time     Tx Time
         (MHz)             Type No.   Time duration              found         (ms)       Limit (ms)
                    5560            0 200ms                                  7     2.1875         200
                                      remaining 9.8s
                    5560            0 period                                 47       14.6875                60

       Last transmission after injection of radar is 2.117 seconds, therefore meeting channel closing time 10s requirement.



    NOTE: Accredited test.                                                                                 Page 9 of 10


Report Template Document Number : FCD-0107                                              Report ID: 14913-RF-00062
Report Template Revision Number :  Rev. C                                                  FCC ID: AZ492FT7124
                                                                                               IC: 109U-92FT7124


               Non-Occupancy Period




               No pulses were detected in the 30 minutes that followed after channel move time, meeting non-occupancy 30
               minute requirement.




                                END OF TEST REPORT




    NOTE: Accredited test.                                                                            Page 10 of 10



Document Created: 2019-08-16 10:31:16
Document Modified: 2019-08-16 10:31:16

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC