Response to FCC Questions

FCC ID: AZ489FT5875

Cover Letter(s)

Download: PDF
FCCID_4041848

Applicant: Motorola Solutions Inc                             FCC ID: AZ489FT5875 / IC: 109U-89FT5875


Response to TIMCO

SUBJECT: TIMCO-TCB/FCC RT - MOTOROLA SOLUTIONS, INC._AZ4 - FCC ID: AZ489FT5875 - JOB #:
1338UC18

Q1) The filing has two test reports and test photo exhibits from different test labs. The filing needs to be
based on the test report chosen and appropriate radio parameters for the grant.

R1) Motorola Penang Adv. Comm. Laboratory tested everything required, except for radiated emissions.
PC Test lab tested for radiated emissions. Both test reports should be acceptable.

Q2) The filing does not indicate how the device complies with the requirement that hop frequencies are
used equally on average. Please provide a list of frequencies and details of how the frequencies will be
used equally on average and considering all modes of operation.

R2) A pseudorandom sequence is employed for hop frequency selection among 50 different frequencies
within 902-928MHz, with 500kHz separation. The histogram below plotted based on the frequency hop
of the transmitter device which indicates that all the 50 different frequencies are equally used on
average.


Applicant: Motorola Solutions Inc                           FCC ID: AZ489FT5875 / IC: 109U-89FT5875


Q3) The filing does not indicate how the hop set meets the requirement that a pseudorandom sequence
is used.

R3) To ensure the pseudorandom sequence is complied, the first transmit hop frequency will always
resume from the last position in the pseudorandom sequence of the transmitter’s previous transmission.
This is achieved by referring to the seed sent in the SYNCH SLOT ID block. The seed indicates the position
in the sequence of the transmitter's previous transmission.