RF Exposure Appendix B

FCC ID: APYHRO00275

RF Exposure Info

Download: PDF
FCCID_4450842

Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab   Date: 2019/8/9

#01_GSM850_GPRS (4 Tx slots)_Right Cheek_Ch128


Communication System: GSM850; Frequency: 824.2 MHz;Duty Cycle: 1:2.08
Medium: HSL_850_190809 Medium parameters used: f = 824.2 MHz; σ = 0.868 S/m; εr = 40.855;
ρ = 1000 kg/m3
                    23.1                      22.1

DASY5 Configuration:
- Probe: ES3DV3 - SN3270; ConvF(6.39, 6.39, 6.39) @ 824.2 MHz; Calibrated: 2018/9/24
- Sensor-Surface: 3mm (Mechanical Surface Detection)
- Electronics: DAE3 Sn577; Calibrated: 2018/9/19
- Phantom: SAM_Left; Type: QD000P40CD; Serial: TP:1431
- Measurement SW: DASY52, Version 52.10 (2);SEMCAD X Version 14.6.12 (7470)


Area Scan (61x121x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm
Maximum value of SAR (interpolated) = 0.147 W/kg

Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value = 13.38 V/m; Power Drift = -0.08 dB
Peak SAR (extrapolated) = 0.171 W/kg
SAR(1 g) = 0.137 W/kg; SAR(10 g) = 0.107 W/kg
Maximum value of SAR (measured) = 0.147 W/kg




               0 dB = 0.147 W/kg = -8.33 dBW/kg


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab   Date: 2019/8/10

#02_GSM1900_GPRS (4 Tx slots)_Left Tilted_Ch512


Communication System: PCS ; Frequency: 1850.2 MHz;Duty Cycle: 1:2.08
Medium: HSL_1900_190810 Medium parameters used: f = 1850.2 MHz; σ = 1.367 S/m; εr =
39.394; ρ = 1000 kg/m3
                      23.3                     22.3

DASY5 Configuration:
- Probe: ES3DV3 - SN3270; ConvF(5.17, 5.17, 5.17) @ 1850.2 MHz; Calibrated: 2018/9/24
- Sensor-Surface: 3mm (Mechanical Surface Detection)
- Electronics: DAE3 Sn577; Calibrated: 2018/9/19
- Phantom: SAM-Right; Type: SAM; Serial: TP-1503
- Measurement SW: DASY52, Version 52.10 (2);SEMCAD X Version 14.6.12 (7470)


Area Scan (71x101x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm
Maximum value of SAR (interpolated) = 0.0414 W/kg

Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value = 5.496 V/m; Power Drift = 0.10 dB
Peak SAR (extrapolated) = 0.0600 W/kg
SAR(1 g) = 0.032 W/kg; SAR(10 g) = 0.017 W/kg
Maximum value of SAR (measured) = 0.0410 W/kg




               0 dB = 0.0410 W/kg = -13.87 dBW/kg


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab   Date: 2019/8/9

#03_WCDMA V_RMC 12.2Kbps_Right Cheek_Ch4132


Communication System: WCDMA; Frequency: 826.4 MHz;Duty Cycle: 1:1
Medium: HSL_850_190809 Medium parameters used : f = 826.4 MHz; σ = 0.87 S/m; εr = 40.83; ρ
= 1000 kg/m3
                    23.1                     22.1

DASY5 Configuration:
- Probe: ES3DV3 - SN3270; ConvF(6.39, 6.39, 6.39) @ 826.4 MHz; Calibrated: 2018/9/24
- Sensor-Surface: 3mm (Mechanical Surface Detection)
- Electronics: DAE3 Sn577; Calibrated: 2018/9/19
- Phantom: SAM_Left; Type: QD000P40CD; Serial: TP:1431
- Measurement SW: DASY52, Version 52.10 (2);SEMCAD X Version 14.6.12 (7470)


Area Scan (61x121x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm
Maximum value of SAR (interpolated) = 0.108 W/kg

Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value = 11.54 V/m; Power Drift = 0.01 dB
Peak SAR (extrapolated) = 0.125 W/kg
SAR(1 g) = 0.101 W/kg; SAR(10 g) = 0.079 W/kg
Maximum value of SAR (measured) = 0.109 W/kg




               0 dB = 0.109 W/kg = -9.63 dBW/kg


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab   Date: 2019/8/9

#04_LTE Band 5_10M_QPSK_1_25_Right Cheek_Ch20525


Communication System: LTE; Frequency: 836.5 MHz;Duty Cycle: 1:1
Medium: HSL_850_190809 Medium parameters used : f = 836.5 MHz; σ = 0.879 S/m; εr = 40.703;
ρ = 1000 kg/m3
                    23.1                      22.1

DASY5 Configuration:
- Probe: ES3DV3 - SN3270; ConvF(6.39, 6.39, 6.39) @ 836.5 MHz; Calibrated: 2018/9/24
- Sensor-Surface: 3mm (Mechanical Surface Detection)
- Electronics: DAE3 Sn577; Calibrated: 2018/9/19
- Phantom: SAM_Left; Type: QD000P40CD; Serial: TP:1431
- Measurement SW: DASY52, Version 52.10 (2);SEMCAD X Version 14.6.12 (7470)


Area Scan (61x121x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm
Maximum value of SAR (interpolated) = 0.0945 W/kg

Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value = 10.59 V/m; Power Drift = 0.05 dB
Peak SAR (extrapolated) = 0.108 W/kg
SAR(1 g) = 0.088 W/kg; SAR(10 g) = 0.069 W/kg
Maximum value of SAR (measured) = 0.0949 W/kg




               0 dB = 0.0949 W/kg = -10.23 dBW/kg


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab   Date: 2019/8/10

#05_LTE Band 12_10M_QPSK_1_0_Right Cheek_Ch23095


Communication System: LTE; Frequency: 707.5 MHz;Duty Cycle: 1:1
Medium: HSL_750_190810 Medium parameters used: f = 707.5 MHz; σ = 0.85 S/m; εr = 41.407; ρ
= 1000 kg/m3
                    23.3                      22.3

DASY5 Configuration:
- Probe: ES3DV3 - SN3270; ConvF(6.56, 6.56, 6.56) @ 707.5 MHz; Calibrated: 2018/9/24
- Sensor-Surface: 3mm (Mechanical Surface Detection)
- Electronics: DAE3 Sn577; Calibrated: 2018/9/19
- Phantom: SAM_Left; Type: QD000P40CD; Serial: TP:1431
- Measurement SW: DASY52, Version 52.10 (2);SEMCAD X Version 14.6.12 (7470)


Area Scan (61x121x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm
Maximum value of SAR (interpolated) = 0.0509 W/kg

Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value = 7.853 V/m; Power Drift = 0.10 dB
Peak SAR (extrapolated) = 0.0570 W/kg
SAR(1 g) = 0.049 W/kg; SAR(10 g) = 0.039 W/kg
Maximum value of SAR (measured) = 0.0521 W/kg




               0 dB = 0.0521 W/kg = -12.83 dBW/kg


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab   Date: 2019/8/12


#06_WLAN2.4GHz_802.11b 1Mbps_Right Cheek_Ch6



Communication System: 802.11b; Frequency: 2437 MHz;Duty Cycle: 1:1.01
Medium: HSL_2450_190812 Medium parameters used : £= 2437 MHz; 0 = 1.812 S/m; & = 39.415; p =
1000 kg/m>
Ambient Temperature : 23.2 °C ; Liquid Temperature : 22.2 °C

DASY5 Configuration:
— Probe: EX3DV4 — SN3728; ConvF(7.11, 7.11, 7.11) @ 2437 MHz; Calibrated: 2019/1/15
— Sensor—Surface: 1.4mm (Mechanical Surface Detection)
— Electronics: DAE4 Sn778; Calibrated: 2019/5/21
— Phantom: SAM_Right; Type: SAM; Serial: TP:1681
— Measurement SW: DASY52, Version 52.10 (2),SEMCAD X Version 14.6.12 (7470)


Area Scan (81x81x1); Interpolated grid: dx=1.200 mm, dy=1.200 mm
Maximum value of SAR (interpolated) = 0.662 W/kg

Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm
Reference Value = 17.76 V/m;, Power Drift = —0.01 dB
Peak SAR (extrapolated) = 0.869 W/kg
SAR(1 g) = 0.363 W/kg; SAR(10 g) = 0.186 W/keg
Maximum value of SAR (measured) = 0.632 W/kg

        dB
         0


        —4.00


        —8.00


        —12.00


        —16.00


        —20.00      |~T
                    0 dB = 0.632 W/kg = —1.99 dBW/kg


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab   Date: 2019/8/12


#07_WLANSGHz_802.11n—HT40 MCSO_Right Cheek_Ch62



Communication System: 802.11n; Frequency: 5310 MHz;Duty Cycle: 1:1.108
Medium: HSL_5G_190812 Medium parameters used: f = 5310 MHz; 0 = 4.703 S/m; g, = 35.797; p = 1000
kg/m3
Ambient Temperature : 23.1 °C ; Liquid Temperature : 22.1 °C

DASY5 Configuration:
— Probe: EX3DV4 — SN3728; ConvF(4.77, 4.77, 4.77) @ 5310 MHz; Calibrated: 2019/1/15
— Sensor—Surface: 1.4mm (Mechanical Surface Detection)
— Electronics: DAE4 Sn778; Calibrated: 2019/5/21
— Phantom: SAM_Left; Type: QDOOOP4O0CD; Serial: TP:1682
— Measurement SW: DASY52, Version 52.10 (2),SEMCAD X Version 14.6.12 (7470)


Area Scan (101x121x1); Interpolated grid: dx=1.000 mm, dy=1.000 mm
Maximum value of SAR (interpolated) = 1.12 W/kg

Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=4mm, dy=4mm, dz=1.4mm
Reference Value = 7.111 V/m;, Power Drift = 0.14 dB
Peak SAR (extrapolated) =3.10 W/kg
SAR(1 g) = 0.776 W/kg; SAR(10 g) = 0.206 W/keg
Maximum value of SAR (measured) = 1.97 W/kg

        dB
         0


        —6.92


        —13.841


        —20.76


        —27.68


        —34.60      T
                    0 dB = 1.97 W/kg = 2.94 dBW/kg


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab   Date: 2019/8/12


#08_WLANSGHz_802.11ac—VHT80 MCSO_Right Cheek_Ch106



Communication System: 802.11ac; Frequency : 5530 MHz;Duty Cycle: 1:1.168
Medium: HSL_5G_190812 Medium parameters used: f = 5530 MHz; 0 = 4.914 S/m; g, = 35.486; p = 1000
kg/m3
Ambient Temperature : 23.1 °C ; Liquid Temperature : 22.1 °C

DASY5 Configuration:
— Probe: EX3DV4 — SN3728; ConvF(4.2, 4.2, 4.2) @ 5530 MHz; Calibrated: 2019/1/15
— Sensor—Surface: 1.4mm (Mechanical Surface Detection)
— Electronics: DAE4 Sn778; Calibrated: 2019/5/21
— Phantom: SAM_Left; Type: QDOOOP4O0CD; Serial: TP:1682
— Measurement SW: DASY52, Version 52.10 (2),SEMCAD X Version 14.6.12 (7470)


Area Scan (101x121x1); Interpolated grid: dx=1.000 mm, dy=1.000 mm
Maximum value of SAR (interpolated) = 0.782 W/kg

Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=4mm, dy=4mm, dz=1.4mm
Reference Value = 7.3 12 V/m;, Power Drift = 0.08 dB
Peak SAR (extrapolated) =2.27 W/kg
SAR(1 g) = 0.554 W/kg; SAR(10 g) = 0.122 W/keg
Maximum value of SAR (measured) = 1.77 W/kg

        dB
         0


        —4.00


        —8.00


        —12.00


        —16.00


        —20.00      |~T
                    0 dB = 1.77 W/kg = 2.48 dBW/kg


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab   Date: 2019/8/12


#09_Bluetooth_1Mbps_Right Tilted_Ch39



Communication System: Bluetooth; Frequency: 2441 MHz;Duty Cycle: 1:1.301
Medium: HSL_2450_190812 Medium parameters used: f = 2441 MHz; 0 = 1.84 S/m; g, = 39.468; p = 1000
kg/m3
Ambient Temperature : 23.2 °C ; Liquid Temperature : 22.2 °C

DASY5 Configuration:
— Probe: EX3DV4 — SN3728; ConvF(7.11, 7.11, 7.11) @ 2441 MHz; Calibrated: 2019/1/15
— Sensor—Surface: 1.4mm (Mechanical Surface Detection)
— Electronics: DAE4 Sn778; Calibrated: 2019/5/21
— Phantom: SAM_Right; Type: SAM; Serial: TP:1681
— Measurement SW: DASY52, Version 52.10 (2),SEMCAD X Version 14.6.12 (7470)


Area Scan (81x81x1); Interpolated grid: dx=1.200 mm, dy=1.200 mm
Maximum value of SAR (interpolated) = 0.196 W/kg

Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm
Reference Value = 9.207 V/m;, Power Drift = —0.00 dB
Peak SAR (extrapolated) = 0.204 W/kg
SAR(1 g) = 0.102 W/kg; SAR(10 g) = 0.048 W/kg
Maximum value of SAR (measured) = 0.167 W/kg

        dB
         0


        —3.00


        —6.00


        —9.00

        —12.00


        415.00      T
                    0 dB = 0.167 W/kg = —7.77 dBW/kg


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab   Date: 2019/8/9

#10_GSM850_GPRS (4 Tx slots)_Front_10mm_Ch128


Communication System: GSM850; Frequency: 824.2 MHz;Duty Cycle: 1:2.08
Medium: HSL_850_190809 Medium parameters used: f = 824.2 MHz; σ = 0.868 S/m; εr = 40.855;
ρ = 1000 kg/m3
                    23.1                      22.1

DASY5 Configuration:
- Probe: ES3DV3 - SN3270; ConvF(6.39, 6.39, 6.39) @ 824.2 MHz; Calibrated: 2018/9/24
- Sensor-Surface: 3mm (Mechanical Surface Detection)
- Electronics: DAE3 Sn577; Calibrated: 2018/9/19
- Phantom: SAM_Left; Type: QD000P40CD; Serial: TP:1431
- Measurement SW: DASY52, Version 52.10 (2);SEMCAD X Version 14.6.12 (7470)


Area Scan (71x121x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm
Maximum value of SAR (interpolated) = 0.218 W/kg

Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value = 16.16 V/m; Power Drift = 0.09 dB
Peak SAR (extrapolated) = 0.252 W/kg
SAR(1 g) = 0.205 W/kg; SAR(10 g) = 0.159 W/kg
Maximum value of SAR (measured) = 0.224 W/kg




               0 dB = 0.224 W/kg = -6.50 dBW/kg


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab   Date: 2019/8/10

#11_GSM1900_GPRS (4 Tx slots)_Bottom Side_10mm_Ch512


Communication System: PCS; Frequency: 1850.2 MHz;Duty Cycle: 1:2.08
Medium: HSL_1900_190810 Medium parameters used : f = 1850.2 MHz; σ = 1.367 S/m; εr =
39.394; ρ = 1000 kg/m3
                      23.3                    22.3

DASY5 Configuration:
- Probe: ES3DV3 - SN3270; ConvF(5.17, 5.17, 5.17) @ 1850.2 MHz; Calibrated: 2018/9/24
- Sensor-Surface: 3mm (Mechanical Surface Detection)
- Electronics: DAE3 Sn577; Calibrated: 2018/9/19
- Phantom: SAM-Right; Type: SAM; Serial: TP-1503
- Measurement SW: DASY52, Version 52.10 (2);SEMCAD X Version 14.6.12 (7470)


Area Scan (41x71x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm
Maximum value of SAR (interpolated) = 0.581 W/kg

Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value = 19.64 V/m; Power Drift = -0.17 dB
Peak SAR (extrapolated) = 0.783 W/kg
SAR(1 g) = 0.447 W/kg; SAR(10 g) = 0.233 W/kg
Maximum value of SAR (measured) = 0.565 W/kg




               0 dB = 0.565 W/kg = -2.48 dBW/kg


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab   Date: 2019/8/9

#12_WCDMA V_RMC 12.2Kbps_Front_10mm_Ch4132


Communication System: WCDMA; Frequency: 826.4 MHz;Duty Cycle: 1:1
Medium: HSL_850_190809 Medium parameters used: f = 826.4 MHz; σ = 0.87 S/m; εr = 40.83; ρ =
1000 kg/m3
                    23.1                     22.1

DASY5 Configuration:
- Probe: ES3DV3 - SN3270; ConvF(6.39, 6.39, 6.39) @ 826.4 MHz; Calibrated: 2018/9/24
- Sensor-Surface: 3mm (Mechanical Surface Detection)
- Electronics: DAE3 Sn577; Calibrated: 2018/9/19
- Phantom: SAM_Left; Type: QD000P40CD; Serial: TP:1431
- Measurement SW: DASY52, Version 52.10 (2);SEMCAD X Version 14.6.12 (7470)


Area Scan (71x121x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm
Maximum value of SAR (interpolated) = 0.154 W/kg

Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value = 13.48 V/m; Power Drift = 0.00 dB
Peak SAR (extrapolated) = 0.174 W/kg
SAR(1 g) = 0.142 W/kg; SAR(10 g) = 0.110 W/kg
Maximum value of SAR (measured) = 0.154 W/kg




               0 dB = 0.154 W/kg = -8.12 dBW/kg


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab   Date: 2019/8/9

#13_LTE Band 5_10M_QPSK_1_25_Right Side_10mm_Ch20525


Communication System: LTE; Frequency: 836.5 MHz;Duty Cycle: 1:1
Medium: HSL_850_190809 Medium parameters used : f = 836.5 MHz; σ = 0.879 S/m; εr = 40.703;
ρ = 1000 kg/m3
                    23.1                      22.1

DASY5 Configuration:
- Probe: ES3DV3 - SN3270; ConvF(6.39, 6.39, 6.39) @ 836.5 MHz; Calibrated: 2018/9/24
- Sensor-Surface: 3mm (Mechanical Surface Detection)
- Electronics: DAE3 Sn577; Calibrated: 2018/9/19
- Phantom: SAM_Left; Type: QD000P40CD; Serial: TP:1431
- Measurement SW: DASY52, Version 52.10 (2);SEMCAD X Version 14.6.12 (7470)


Area Scan (41x111x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm
Maximum value of SAR (interpolated) = 0.192 W/kg

Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value = 15.09 V/m; Power Drift = 0.01 dB
Peak SAR (extrapolated) = 0.238 W/kg
SAR(1 g) = 0.166 W/kg; SAR(10 g) = 0.113 W/kg
Maximum value of SAR (measured) = 0.191 W/kg




               0 dB = 0.191 W/kg = -7.19 dBW/kg


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab   Date: 2019/8/10

#14_LTE Band 12_10M_QPSK_1_0_Right Side_10mm_Ch23095


Communication System: LTE ; Frequency: 707.5 MHz;Duty Cycle: 1:1
Medium: HSL_750_190810 Medium parameters used: f = 707.5 MHz; σ = 0.85 S/m; εr = 41.407; ρ
= 1000 kg/m3
                    23.3                       22.3

DASY5 Configuration:
- Probe: ES3DV3 - SN3270; ConvF(6.56, 6.56, 6.56) @ 707.5 MHz; Calibrated: 2018/9/24
- Sensor-Surface: 3mm (Mechanical Surface Detection)
- Electronics: DAE3 Sn577; Calibrated: 2018/9/19
- Phantom: SAM_Left; Type: QD000P40CD; Serial: TP:1431
- Measurement SW: DASY52, Version 52.10 (2);SEMCAD X Version 14.6.12 (7470)


Area Scan (41x111x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm
Maximum value of SAR (interpolated) = 0.114 W/kg

Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value = 9.807 V/m; Power Drift = 0.17 dB
Peak SAR (extrapolated) = 0.137 W/kg
SAR(1 g) = 0.099 W/kg; SAR(10 g) = 0.070 W/kg
Maximum value of SAR (measured) = 0.113 W/kg




               0 dB = 0.113 W/kg = -9.47 dBW/kg


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab   Date: 2019/8/12


#15_WLAN2.4GHz_802.11b 1Mbps_Front_10mm_Ch6


Communication System: 802.11b; Frequency: 2437 MHz;Duty Cycle: 1:1.01
Medium: HSL_2450_190812 Medium parameters used : £= 2437 MHz; 0 = 1.812 S/m; & = 39.415; p =
1000 kg/m>
Ambient Temperature : 23.2 °C ; Liquid Temperature : 22.2 °C

DASY5 Configuration:
— Probe: EX3DV4 — SN3728; ConvF(7.11, 7.11, 7.11) @ 2437 MHz; Calibrated: 2019/1/15
— Sensor—Surface: 1.4mm (Mechanical Surface Detection)
— Electronics: DAE4 Sn778; Calibrated: 2019/5/21
— Phantom: SAM_Right; Type: SAM; Serial: TP:1681
— Measurement SW: DASY52, Version 52.10 (2),SEMCAD X Version 14.6.12 (7470)


Area Scan (91x81x1):; Interpolated grid: dx=1.200 mm, dy=1.200 mm
Maximum value of SAR (interpolated) = 0.121 W/kg

Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm
Reference Value = 6.631 V/m;, Power Drift = 0.03 dB
Peak SAR (extrapolated) = 0.149 W/kg
SAR(1 g) = 0.071 W/kg; SAR(10 g) = 0.036 W/keg
Maximum value of SAR (measured) = 0.116 W/kg

        dB
         0


        —3.47


        —6.93


        —10.40


        —13.86


        417.33        (C
                    0 dB = 0.116 W/kg = —9.36 dBW/kg


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab   Date: 2019/8/9

#16_GSM850_GPRS (4 Tx slots)_Front_10mm_Ch128


Communication System: GSM850; Frequency: 824.2 MHz;Duty Cycle: 1:2.08
Medium: HSL_850_190809 Medium parameters used: f = 824.2 MHz; σ = 0.868 S/m; εr = 40.855;
ρ = 1000 kg/m3
                    23.1                      22.1

DASY5 Configuration:
- Probe: ES3DV3 - SN3270; ConvF(6.39, 6.39, 6.39) @ 824.2 MHz; Calibrated: 2018/9/24
- Sensor-Surface: 3mm (Mechanical Surface Detection)
- Electronics: DAE3 Sn577; Calibrated: 2018/9/19
- Phantom: SAM_Left; Type: QD000P40CD; Serial: TP:1431
- Measurement SW: DASY52, Version 52.10 (2);SEMCAD X Version 14.6.12 (7470)


Area Scan (71x121x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm
Maximum value of SAR (interpolated) = 0.218 W/kg

Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value = 16.16 V/m; Power Drift = 0.09 dB
Peak SAR (extrapolated) = 0.252 W/kg
SAR(1 g) = 0.205 W/kg; SAR(10 g) = 0.159 W/kg
Maximum value of SAR (measured) = 0.224 W/kg




               0 dB = 0.224 W/kg = -6.50 dBW/kg


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab   Date: 2019/8/10

#17_GSM1900_GPRS (4 Tx slots)_Front_10mm_Ch512


Communication System: PCS ; Frequency: 1850.2 MHz;Duty Cycle: 1:2.08
Medium: HSL_1900_190810 Medium parameters used : f = 1850.2 MHz; σ = 1.367 S/m; εr =
39.394; ρ = 1000 kg/m3
                      23.3                     22.3

DASY5 Configuration:
- Probe: ES3DV3 - SN3270; ConvF(5.17, 5.17, 5.17) @ 1850.2 MHz; Calibrated: 2018/9/24
- Sensor-Surface: 3mm (Mechanical Surface Detection)
- Electronics: DAE3 Sn577; Calibrated: 2018/9/19
- Phantom: SAM-Right; Type: SAM; Serial: TP-1503
- Measurement SW: DASY52, Version 52.10 (2);SEMCAD X Version 14.6.12 (7470)


Area Scan (71x81x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm
Maximum value of SAR (interpolated) = 0.312 W/kg

Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value = 2.182 V/m; Power Drift = -0.12 dB
Peak SAR (extrapolated) = 0.429 W/kg
SAR(1 g) = 0.248 W/kg; SAR(10 g) = 0.134 W/kg
Maximum value of SAR (measured) = 0.311 W/kg




               0 dB = 0.311 W/kg = -5.07 dBW/kg


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab   Date: 2019/8/9

#18_WCDMA V_RMC 12.2Kbps_Front_10mm_Ch4132


Communication System: WCDMA; Frequency: 826.4 MHz;Duty Cycle: 1:1
Medium: HSL_850_190809 Medium parameters used: f = 826.4 MHz; σ = 0.87 S/m; εr = 40.83; ρ =
1000 kg/m3
                    23.1                     22.1

DASY5 Configuration:
- Probe: ES3DV3 - SN3270; ConvF(6.39, 6.39, 6.39) @ 826.4 MHz; Calibrated: 2018/9/24
- Sensor-Surface: 3mm (Mechanical Surface Detection)
- Electronics: DAE3 Sn577; Calibrated: 2018/9/19
- Phantom: SAM_Left; Type: QD000P40CD; Serial: TP:1431
- Measurement SW: DASY52, Version 52.10 (2);SEMCAD X Version 14.6.12 (7470)


Area Scan (71x121x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm
Maximum value of SAR (interpolated) = 0.154 W/kg

Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value = 13.48 V/m; Power Drift = 0.00 dB
Peak SAR (extrapolated) = 0.174 W/kg
SAR(1 g) = 0.142 W/kg; SAR(10 g) = 0.110 W/kg
Maximum value of SAR (measured) = 0.154 W/kg




               0 dB = 0.154 W/kg = -8.12 dBW/kg


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab   Date: 2019/8/9

#19_LTE Band 5_10M_QPSK_1_25_Front_10mm_Ch20525


Communication System: LTE; Frequency: 836.5 MHz;Duty Cycle: 1:1
Medium: HSL_850_190809 Medium parameters used : f = 836.5 MHz; σ = 0.879 S/m; εr = 40.703;
ρ = 1000 kg/m3
                    23.1                      22.1

DASY5 Configuration:
- Probe: ES3DV3 - SN3270; ConvF(6.39, 6.39, 6.39) @ 836.5 MHz; Calibrated: 2018/9/24
- Sensor-Surface: 3mm (Mechanical Surface Detection)
- Electronics: DAE3 Sn577; Calibrated: 2018/9/19
- Phantom: SAM_Left; Type: QD000P40CD; Serial: TP:1431
- Measurement SW: DASY52, Version 52.10 (2);SEMCAD X Version 14.6.12 (7470)


Area Scan (71x111x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm
Maximum value of SAR (interpolated) = 0.115 W/kg

Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value = 11.57 V/m; Power Drift = 0.11 dB
Peak SAR (extrapolated) = 0.132 W/kg
SAR(1 g) = 0.106 W/kg; SAR(10 g) = 0.082 W/kg
Maximum value of SAR (measured) = 0.115 W/kg




               0 dB = 0.115 W/kg = -9.39 dBW/kg


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab   Date: 2019/8/10

#20_LTE Band 12_10M_QPSK_1_0_Front_10mm_Ch23095


Communication System: LTE ; Frequency: 707.5 MHz;Duty Cycle: 1:1
Medium: HSL_750_190810 Medium parameters used: f = 707.5 MHz; σ = 0.85 S/m; εr = 41.407; ρ
= 1000 kg/m3
                    23.3                       22.3

DASY5 Configuration:
- Probe: ES3DV3 - SN3270; ConvF(6.56, 6.56, 6.56) @ 707.5 MHz; Calibrated: 2018/9/24
- Sensor-Surface: 3mm (Mechanical Surface Detection)
- Electronics: DAE3 Sn577; Calibrated: 2018/9/19
- Phantom: SAM_Left; Type: QD000P40CD; Serial: TP:1431
- Measurement SW: DASY52, Version 52.10 (2);SEMCAD X Version 14.6.12 (7470)


Area Scan (71x111x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm
Maximum value of SAR (interpolated) = 0.0902 W/kg

Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value = 10.29 V/m; Power Drift = -0.05 dB
Peak SAR (extrapolated) = 0.100 W/kg
SAR(1 g) = 0.083 W/kg; SAR(10 g) = 0.066 W/kg
Maximum value of SAR (measured) = 0.0903 W/kg




               0 dB = 0.0903 W/kg = -10.44 dBW/kg


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab   Date: 2019/8/12


#21_WLAN2.4GHz_802.11b 1Mbps_Front_10mm_Ch6


Communication System: 802.11b; Frequency: 2437 MHz;Duty Cycle: 1:1.01
Medium: HSL_2450_190812 Medium parameters used : £= 2437 MHz; 0 = 1.812 S/m; & = 39.415; p =
1000 kg/m>
Ambient Temperature : 23.2 °C ; Liquid Temperature : 22.2 °C

DASY5 Configuration:
— Probe: EX3DV4 — SN3728; ConvF(7.11, 7.11, 7.11) @ 2437 MHz; Calibrated: 2019/1/15
— Sensor—Surface: 1.4mm (Mechanical Surface Detection)
— Electronics: DAE4 Sn778; Calibrated: 2019/5/21
— Phantom: SAM_Right; Type: SAM; Serial: TP:1681
— Measurement SW: DASY52, Version 52.10 (2),SEMCAD X Version 14.6.12 (7470)


Area Scan (91x81x1):; Interpolated grid: dx=1.200 mm, dy=1.200 mm
Maximum value of SAR (interpolated) = 0.121 W/kg

Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm
Reference Value = 6.631 V/m;, Power Drift = 0.03 dB
Peak SAR (extrapolated) = 0.149 W/kg
SAR(1 g) = 0.071 W/kg; SAR(10 g) = 0.036 W/keg
Maximum value of SAR (measured) = 0.116 W/kg

        dB
         0


        —3.47


        —6.93


        —10.40


        —13.86


        417.33        (C
                    0 dB = 0.116 W/kg = —9.36 dBW/kg


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab   Date: 2019/8/12


#22_WLANSGHz_802.11ac—VHT80 MCSO_Front_10mm_Ch58


Communication System: 802.11ac; Frequency : 5290 MHz;Duty Cycle: 1:1.168
Medium: HSL_5G_190812 Medium parameters used: f = 5290 MHz; 0 = 4.686 S/m; g, = 35.826; p = 1000
kg/m3
Ambient Temperature : 23.1 °C ; Liquid Temperature : 22.1 °C

DASY5 Configuration:
— Probe: EX3DV4 — SN3728; ConvF(4.77, 4.77, 4.77) @ 5290 MHz; Calibrated: 2019/1/15
— Sensor—Surface: 1.4mm (Mechanical Surface Detection)
— Electronics: DAE4 Sn778; Calibrated: 2019/5/21
— Phantom: SAM_Left; Type: QDOOOP4O0CD; Serial: TP:1682
— Measurement SW: DASY52, Version 52.10 (2),SEMCAD X Version 14.6.12 (7470)


Area Scan (121x101x1): Interpolated grid: dx=1.000 mm, dy=1.000 mm
Maximum value of SAR (interpolated) = 0.218 W/kg

Zoom Scan (8x8x7)/Cube 0: Measurement grid: dx=4mm, dy=4mm, dz=1.4mm
Reference Value = 4.231 V/m;, Power Drift = 0.03 dB
Peak SAR (extrapolated) = 0.417 W/kg
SAR(1 g) = 0.132 W/kg; SAR(10 g) = 0.051 W/kg
Maximum value of SAR (measured) = 0.279 W/kg

        dB
         0


        —3.60


        —1.20


        —10.80


        —14.40


        —18.00        C
                    0 dB = 0.279 W/kg = —5.54 dBW/kg


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab   Date: 2019/8/12


#23_WLANSGHz_802.11ac—VHT80 MCSO_Front_10mm_Ch106


Communication System: 802.11ac; Frequency : 5530 MHz;Duty Cycle: 1:1.168
Medium: HSL_5G_190812 Medium parameters used: f = 5530 MHz; 0 = 4.914 S/m; g, = 35.486; p = 1000
kg/m3
Ambient Temperature : 23.1 °C ; Liquid Temperature : 22.1 °C

DASY5 Configuration:
— Probe: EX3DV4 — SN3728; ConvF(4.2, 4.2, 4.2) @ 5530 MHz; Calibrated: 2019/1/15
— Sensor—Surface: 1.4mm (Mechanical Surface Detection)
— Electronics: DAE4 Sn778; Calibrated: 2019/5/21
— Phantom: SAM_Left; Type: QDOOOP4O0CD; Serial: TP:1682
— Measurement SW: DASY52, Version 52.10 (2),SEMCAD X Version 14.6.12 (7470)


Area Scan (121x101x1): Interpolated grid: dx=1.000 mm, dy=1.000 mm
Maximum value of SAR (interpolated) = 0.132 W/kg

Zoom Scan (Ox9x7)/Cube 0: Measurement grid: dx=4mm, dy=4mm, dz=1.4mm
Reference Value = 5.324 V/m;, Power Drift =—0.14 dB
Peak SAR (extrapolated) = 0.350 W/kg
SAR(1 g) = 0.079 W/kg; SAR(10 g) = 0.032 W/keg
Maximum value of SAR (measured) = 0.174 W/kg

        dB
         0


        —3.51


        —£.01


        —10.52


        —14.02


        17.53         (C
                    0 dB = 0.174 W/kg = —7.59 dBW/kg