Test Report NFC

FCC ID: APYHRO00271

Test Report

Download: PDF
FCCID_4136320

                                                                                                                                          Report No: ER/2018/C0137
                                                                                                                                          Page: 1 of 37




                ELECTROMAGNETIC EMISSIONS COMPLIANCE REPORT

                                  INTENTIONAL RADIATOR CERTIFICATION TO
                                    FCC PART 15 SUBPART C REQUIREMENT
                                                                                             OF
                                                               Sharp Corporation, Mobile Communication B.U.
          Applicant:                                           2-13-1, Hachihonmatsu-Iida, Higashi-hiroshima-shi,
                                                               Hiroshima, 739-0192, Japan
                                                               Sharp Corporation
          Manufacturer:
                                                               1 Takumi-cho, Sakai-ku, Sakai City,Osaka 590-8522,Japan
          Product Name:                                        Cellular Phone
          Report Number:                                       ER/2018/C0137
          FCC ID:                                              APYHRO00271
          FCC Rule Part                                        Part 15.225
          Issue Date:                                          Dec. 21, 2018
          Date of Test:                                        Oct. 25, 2018 ~ Nov. 29, 2018
          Date of EUT Received:                                Oct. 25, 2018
          We hereby certify that:
          The above equipment was tested by SGS Taiwan Ltd. The test data, data evaluation, test
          procedures, and equipment configurations shown in this report were made in accordance with the
          procedures given in ANSI C63.10:2013 and the energy emitted by the sample EUT tested as
          described in this report is in compliance with conducted and radiated emission limits of FCC
          Rules Part 15.225.
          The test results of this report relate only to the tested sample identified in this report.




             Tested By:
                                           Marcus Tseng / Sr. Engineer



          Approved By:
                                           Jazz Huang / Asst. Supervisor




Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only.
除非另有說明,此報告結果僅對測試之樣品負責,同時此樣品僅保留90天。本報告未經本公司書面許可,不可部份複製。
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for
electronic format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability,
indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention
only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all
their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration,
forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law.
                                         SGS Taiwan Ltd. No.134,WuKungRoad,NewTaipeiIndustrialPark,WukuDistrict,NewTaipeiCity,Taiwan24803/新北市五股區新北產業園區五工路
 134號
                          台灣檢驗科技股份有限公司                                                            t (886-2) 2299-3279                    f (886-2) 2298-0488            www.tw.sgs.com
                                                                                                                                             Member of SGS Group


                                                                                                                                          Report No: ER/2018/C0137
                                                                                                                                          Page: 2 of 37




                                                                    Revision History
                                                                                                                 Effected
    Report Number                         Revision                        Description                                                      Issue Date                   Revised By
                                                                                                                  Page
                                                                       Initial creation of
     ER/2018/C0137                           Rev.00                                                                    All               Dec. 21, 2018                   Stefanie Yu
                                                                            document




Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only.
除非另有說明,此報告結果僅對測試之樣品負責,同時此樣品僅保留90天。本報告未經本公司書面許可,不可部份複製。
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for
electronic format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability,
indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention
only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all
their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration,
forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law.
                                         SGS Taiwan Ltd. No.134,WuKungRoad,NewTaipeiIndustrialPark,WukuDistrict,NewTaipeiCity,Taiwan24803/新北市五股區新北產業園區五工路
 134號
                          台灣檢驗科技股份有限公司                                                            t (886-2) 2299-3279                    f (886-2) 2298-0488            www.tw.sgs.com
                                                                                                                                             Member of SGS Group


                                                                                                                                          Report No: ER/2018/C0137
                                                                                                                                          Page: 3 of 37




                                                                                Contents
    1 GENERAL INFORMATION ................................................................................................. 4
    2 SYSTEM TEST CONFIGURATION..................................................................................... 6
    3 SUMMARY OF TEST RESULTS ...................................................................................... 10
    4 DESCRIPTION OF TEST MODES.................................................................................... 10
    5 MEASUREMENT UNCERTAINTY .....................................................................................11
    6 CONDUCTED EMISSIONS TEST .................................................................................... 12
    7 RADIATED EMISSION TEST............................................................................................ 16
    8 FREQUENCY TOLERANCE............................................................................................. 29
    9 20 dB OCCUPIED BANDWIDTH MEASUREMENT......................................................... 34
    10 ANTENNA REQUIREMENT.............................................................................................. 37




Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only.
除非另有說明,此報告結果僅對測試之樣品負責,同時此樣品僅保留90天。本報告未經本公司書面許可,不可部份複製。
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for
electronic format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability,
indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention
only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all
their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration,
forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law.
                                         SGS Taiwan Ltd. No.134,WuKungRoad,NewTaipeiIndustrialPark,WukuDistrict,NewTaipeiCity,Taiwan24803/新北市五股區新北產業園區五工路
 134號
                          台灣檢驗科技股份有限公司                                                            t (886-2) 2299-3279                    f (886-2) 2298-0488            www.tw.sgs.com
                                                                                                                                             Member of SGS Group


                                                                                                                                          Report No: ER/2018/C0137
                                                                                                                                          Page: 4 of 37




1 GENERAL INFORMATION

1.1 Product Description
General:
     Product Name:                                                   Cellular Phone
     Hardware Version:                                               DVT
     Software Version:                                               N/A
    Power Supply:                                                     3.8V from Rechargeable Li-ion Battery

NFC:
     Operating Frequency                                             13.56MHz
     Transmit Power                                                  < 123dBuV/m at 3m.
     Number of Channels                                              1
     Antenna Type                                                     Loop Antenna
     Modulation Type                                                 ASK




Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only.
除非另有說明,此報告結果僅對測試之樣品負責,同時此樣品僅保留90天。本報告未經本公司書面許可,不可部份複製。
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for
electronic format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability,
indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention
only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all
their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration,
forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law.
                                         SGS Taiwan Ltd. No.134,WuKungRoad,NewTaipeiIndustrialPark,WukuDistrict,NewTaipeiCity,Taiwan24803/新北市五股區新北產業園區五工路
 134號
                          台灣檢驗科技股份有限公司                                                            t (886-2) 2299-3279                    f (886-2) 2298-0488            www.tw.sgs.com
                                                                                                                                             Member of SGS Group


                                                                                                                                          Report No: ER/2018/C0137
                                                                                                                                          Page: 5 of 37




1.2 Test Methodology
              FCC Part 15, Subpart C §15.225
              ANSI C63.10:2013
              Note: All test items have been performed and record as per the above standards.
1.3 Test Facility
              SGS Taiwan Ltd. Electronics & Communication Laboratory No.134, Wu Kung
              Road, New Taipei Industrial Park, Wuku District, New Taipei City, Taiwan 24803
              (TAF code 0513)
              FCC Registration Number and Designation number are: 509634 / TW0001

1.4 Special Accessories
      There is no special accessory used while test was conducted.
1.5 Equipment Modifications
      There was no modification incorporated into the EUT.

1.6 Radiated Emission Test Sites For Measurements From 9 kHz To 30 MHz
      Radiated emission below 30MHz is measured in a 9m*9m*6m semi-anechoic chamber,
      the measurements correspond to those obtained at an open-field test site.
1.7 Referencing test data across separate equipment authorization
      The test report ER/2018/B0075 under original FCC ID: APYHRO00268 are fully referred
      for the new FCC ID: APYHRO00271 in this report.




Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only.
除非另有說明,此報告結果僅對測試之樣品負責,同時此樣品僅保留90天。本報告未經本公司書面許可,不可部份複製。
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for
electronic format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability,
indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention
only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all
their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration,
forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law.
                                         SGS Taiwan Ltd. No.134,WuKungRoad,NewTaipeiIndustrialPark,WukuDistrict,NewTaipeiCity,Taiwan24803/新北市五股區新北產業園區五工路
 134號
                          台灣檢驗科技股份有限公司                                                            t (886-2) 2299-3279                    f (886-2) 2298-0488            www.tw.sgs.com
                                                                                                                                             Member of SGS Group


                                                                                                                                          Report No: ER/2018/C0137
                                                                                                                                          Page: 6 of 37




2 SYSTEM TEST CONFIGURATION

2.1 EUT Configuration
      The EUT configuration for testing is installed on RF field strength measurement to
      meet the Commissions requirement and operating in a manner which intends to
      maximize its emission characteristics in a continuous normal application.

2.2 EUT Exercise
      The Transmitter was operated in the normal operating mode. the Tx frequency was
      fixed which was for the purpose of the measurements.
2.3 Test Procedure

    2.3.1 Conducted Emissions
           The EUT is a placed on as turn table which is 0.8m above ground plane. Conducted
           emissions from the EUT measured in the frequency range between 0.15 MHz and
           30MHz,. The CISPR Quasi-Peak and Average detector mode is employed according
           to §15.107. The two LISNs provide 50 ohm/ 50uH of coupling impedance for the
           measuring instrument. Both lines of the power mains connected to the EUT were
           checked for maximum conducted interference.
    2.3.2 Radiated Emissions
                  The EUT is a placed on as turn table. For emissions testing at or below 1 GHz, the
                  table height shall be 0.8 m above the reference ground plane. For emission
                  measurements above 1 GHz, the table height shall be 1.5 m above the reference
                  ground plane. The turn table shall rotate 360 degrees to determine the position of
                  maximum emission level. EUT is set 3m away from the receiving antenna which
                  varied from 1m to 4m to find out the highest emission. And also, each emission was
                  to be maximized by changing the polarization of receiving antenna both horizontal
                  and vertical. In order to find out the max. emission, the relative positions of this
                  transmitter (EUT) was rotated through three orthogonal axes and measurement
                  procedures for electric field radiated emissions above 1 GHz the EUT measurement
                  is to be made “while keeping the antenna in the ‘cone of radiation’ from that area and
                  pointed at the area both in azimuth and elevation, with polarization oriented for
                  maximum response.” is still within the 3dB illumination BW of the measurement
                  antenna.




Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only.
除非另有說明,此報告結果僅對測試之樣品負責,同時此樣品僅保留90天。本報告未經本公司書面許可,不可部份複製。
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for
electronic format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability,
indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention
only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all
their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration,
forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law.
                                         SGS Taiwan Ltd. No.134,WuKungRoad,NewTaipeiIndustrialPark,WukuDistrict,NewTaipeiCity,Taiwan24803/新北市五股區新北產業園區五工路
 134號
                          台灣檢驗科技股份有限公司                                                            t (886-2) 2299-3279                    f (886-2) 2298-0488            www.tw.sgs.com
                                                                                                                                             Member of SGS Group


                                                                                                                                          Report No: ER/2018/C0137
                                                                                                                                          Page: 7 of 37




2.4 Limitation

            (1) Conducted Emission
                According to section 15.207(a) Conducted Emission Limits is as following.

                                                                                                              Limits
               Frequency range                                                                               dB (uV)
                     MHz                                               Quasi-peak                                                         Average
                 0.15 to 0.50                                           66 to 56                                                          56 to 46
                   0.50 to 5                                               56                                                               46
                    5 to 30                                                60                                                               50
              Note
              1.The lower limit shall apply at the transition frequencies
              2.The limit decreases linearly with the logarithm of the frequency in the range 0.15 MHz to
              0.50 MHz.


            (2)
                   Radiated Emission
                   a.The field strength of any emission within the band 13.553-13.567 MHz shall
                      not exceed 15,848 microvolts/meter at 30 meters.
                   b.Within the bands 13.410-13.553 MHz and 13.567-13.710 MHz, the field
                      strength of any emissions shall not exceed 334 microvolts/meter at 30 meters.
                   c. Within the bands 13.110-13.410 MHz and 13.710-14.010 MHz the field
                      strength of any emissions shall not exceed 106 microvolts/meter at 30 meters.
                   d.The field strength of any emissions appearing outside of the 13.110-14.010
                      MHz shall not exceed the general radiated emission limits in section 15.209 as
                      below.

                          Frequency                            Field strength                          Distance (m)                     Field strength at 3m
                            (MHz)                                  µV/m                                                                       dBµV/m
                           1.705-30                                       30                                     30                                   69.54
                              30-88                                      100                                      3                                      40
                             88-216                                      150                                      3                                    43.5
                            216-960                                      200                                      3                                      46
                         Above 960                                       500                                      3                                      54




Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only.
除非另有說明,此報告結果僅對測試之樣品負責,同時此樣品僅保留90天。本報告未經本公司書面許可,不可部份複製。
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for
electronic format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability,
indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention
only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all
their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration,
forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law.
                                         SGS Taiwan Ltd. No.134,WuKungRoad,NewTaipeiIndustrialPark,WukuDistrict,NewTaipeiCity,Taiwan24803/新北市五股區新北產業園區五工路
 134號
                          台灣檢驗科技股份有限公司                                                            t (886-2) 2299-3279                    f (886-2) 2298-0488            www.tw.sgs.com
                                                                                                                                             Member of SGS Group


                                                                                                                                          Report No: ER/2018/C0137
                                                                                                                                          Page: 8 of 37




            Remark 1. Emission level in dBuV/m=20 log (uV/m)
            :      2. Measurement was performed at an antenna to the closed point of EUT
                     distance of    meters.
                   3. Distance extrapolation factor = 40 log (required distance/ test distance)
                     (dB);
                   4. The measurement was undertaken in closer distance at 3m, where
                     extrapolation factor is offset to convert the limit of the measurement.
                     Ex.20*log(30)+40*log(30/3) = 69.54dBuV/m
                   5. Only spurious frequency is permitted to locate within the Restricted
                     Bands specified in provision of §15.205.
                   6. The general radiated emission limits in §15.209 apply for the spurious
                     emission generate from UE, except for the fundamental emission where
                     the respective section specifies otherwise.

            (3)
                   Frequency Tolerance
                    The frequency tolerance of the carrier signal shall be maintained within +/-
                    0.01% of the operating frequency over a temperature variation of -20 degrees to
                    +50 degrees C at normal supply voltage, and for a variation in the primary supply
                    voltage from 85% to 115% of the rated supply voltage at a temperature of 20
                    degrees C. For battery operated equipment, the equipment tests shall be
                    performed using a new battery.




Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only.
除非另有說明,此報告結果僅對測試之樣品負責,同時此樣品僅保留90天。本報告未經本公司書面許可,不可部份複製。
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for
electronic format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability,
indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention
only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all
their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration,
forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law.
                                         SGS Taiwan Ltd. No.134,WuKungRoad,NewTaipeiIndustrialPark,WukuDistrict,NewTaipeiCity,Taiwan24803/新北市五股區新北產業園區五工路
 134號
                          台灣檢驗科技股份有限公司                                                            t (886-2) 2299-3279                    f (886-2) 2298-0488            www.tw.sgs.com
                                                                                                                                             Member of SGS Group


                                                                                                                                          Report No: ER/2018/C0137
                                                                                                                                          Page: 9 of 37




2.5 Configuration of Tested System
                                 Fig. 2-1 Radiated Emission




                                                      Fig. 2-2 AC Power Line Conducted Emission




                                                  Table 2-1 Equipment Used in Tested System

                                                                                 Model/Type                                                                         Power
         Item             Equipment                     Mfr/Brand                                              Series No.               Data Cable
                                                                                    No.                                                                              Cord
                           NFC Test
           1.                                           Tera Term                       N/A                          N/A                       N/A                     N/A
                           software
           2.             Notebook                         Lenovo                    T440P                     P0000564                   Shielded Unshielded




Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only.
除非另有說明,此報告結果僅對測試之樣品負責,同時此樣品僅保留90天。本報告未經本公司書面許可,不可部份複製。
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for
electronic format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability,
indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention
only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all
their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration,
forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law.
                                         SGS Taiwan Ltd. No.134,WuKungRoad,NewTaipeiIndustrialPark,WukuDistrict,NewTaipeiCity,Taiwan24803/新北市五股區新北產業園區五工路
 134號
                          台灣檢驗科技股份有限公司                                                            t (886-2) 2299-3279                    f (886-2) 2298-0488            www.tw.sgs.com
                                                                                                                                             Member of SGS Group


                                                                                                                                          Report No: ER/2018/C0137
                                                                                                                                          Page: 10 of 37




3 SUMMARY OF TEST RESULTS

                                  FCC Rules                               Description Of Test                                                 Result
                                                                        AC Power Line Conducted
                                     §15.207                                                                                               Compliant
                                                                                Emission
                               §15.225 (a)-(d)                             Radiated Emission                                               Compliant
                                                                        Radiated Emission Limits,
                                     §15.209                                                                                               Compliant
                                                                          general requirement
                                  §15.225 (e)                              Frequency Stability                                             Compliant
                                   §2.1049                                 20 dB OCCUPIED
                                                                                                                                           Compliant
                                  §15.215 (c)                                 BANDWIDTH
                                   §15.203                               Antenna Requirement                                               Compliant



4 DESCRIPTION OF TEST MODES
     The EUT stay in continuous transmitting mode. The frequency 13.56MHz is the default
     channel to test, where it is the only manipulative channel as this application supports.

     The field strength of spurious radiation emission was measured as EUT stand-up position (H
     mode) and lie down position (E1, E2 mode), the worst case H position was reported.

     The data rate as the lowest supported is selected while tests are conducted.




Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only.
除非另有說明,此報告結果僅對測試之樣品負責,同時此樣品僅保留90天。本報告未經本公司書面許可,不可部份複製。
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for
electronic format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability,
indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention
only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all
their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration,
forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law.
                                         SGS Taiwan Ltd. No.134,WuKungRoad,NewTaipeiIndustrialPark,WukuDistrict,NewTaipeiCity,Taiwan24803/新北市五股區新北產業園區五工路
 134號
                          台灣檢驗科技股份有限公司                                                            t (886-2) 2299-3279                    f (886-2) 2298-0488            www.tw.sgs.com
                                                                                                                                             Member of SGS Group


                                                                                                                                          Report No: ER/2018/C0137
                                                                                                                                          Page: 11 of 37




5 MEASUREMENT UNCERTAINTY

                                                  Test Items                                                        Uncertainty
                                    AC Power Line Conducted
                                                                                                                     +/- 2.586 dB
                                          Emission
                                            Frequency Stability                                                     +/- 123.36 Hz
                              20 dB OCCUPIED BANDWIDTH                                                              +/- 123.36 Hz
                                                  Temperature                                                           +/- 0.8 °C
                                                      Humidity                                                           +/- 4.7 %
                                        DC / AC Power Source                                            DC= +/- 1%, AC=+/- 0.2%

          Radiated Spurious Emission:
            Measurement uncertainty                                                                   9kHz - 30MHz: +/- 2.3dB


                                                                                                30MHz - 180MHz: +/- 3.37dB
            Measurement uncertainty
             (Polarization : Vertical)                                                          180MHz -417MHz: +/- 3.19dB
                                                                                                 0.417GHz-1GHz: +/- 3.19dB

                                                                                                30MHz - 167MHz: +/- 4.22dB
           Measurement uncertainty
           (Polarization : Horizontal)                                                          167MHz -500MHz: +/- 3.44dB
                                                                                                  0.5GHz-1GHz: +/- 3.39dB

       This uncertainty represents an expanded uncertainty expressed at approximately the 95%
       confidence level using a coverage factor of k=2.




Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only.
除非另有說明,此報告結果僅對測試之樣品負責,同時此樣品僅保留90天。本報告未經本公司書面許可,不可部份複製。
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for
electronic format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability,
indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention
only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all
their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration,
forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law.
                                         SGS Taiwan Ltd. No.134,WuKungRoad,NewTaipeiIndustrialPark,WukuDistrict,NewTaipeiCity,Taiwan24803/新北市五股區新北產業園區五工路
 134號
                          台灣檢驗科技股份有限公司                                                            t (886-2) 2299-3279                    f (886-2) 2298-0488            www.tw.sgs.com
                                                                                                                                             Member of SGS Group


                                                                                                                                          Report No: ER/2018/C0137
                                                                                                                                          Page: 12 of 37




6 CONDUCTED EMISSIONS TEST
6.1 Standard Applicable
         Frequency within 150 kHz to 30MHz shall not exceed the limit table as below.
                                                              Limits
              Frequency range                                 dB(uV)
                    MHz                     Quasi-peak                        Average
                0.15 to 0.50                  66 to 56                        56 to 46
                  0.50 to 5                       56                             46
                   5 to 30                        60                             50
        Note
        1.The lower limit shall apply at the transition frequencies
        2.The limit decreases linearly with the logarithm of the frequency in the range 0.15 MHz to 0.50
        MHz.


6.2 Measurement Equipment Used:
            EQUIPMENT                                                                   MODEL                   SERIAL
                                                              MFR                                                      LAST CAL. CAL DUE.
                TYPE                                                                   NUMBER                  NUMBER
           EMI Test Receiver                          R&S                               ESCI7                   100335 02/02/2018 02/01/2019
                                                   SCHWARZBEC
                        LISN                                  NSLK 8127 8127-649 05/18/2018 05/17/2019
                                                       K

6.3 EUT Setup:
        1. The conducted emission tests were performed in the test site, using the setup in
           accordance with the ANSI 63.10:2013.
        2. The AC/DC Power adaptor of EUT was plug-in LISN. The EUT was placed flushed with
           the rear of the table.
        3. The LISN was connected with 120Vac/60Hz power source.




Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only.
除非另有說明,此報告結果僅對測試之樣品負責,同時此樣品僅保留90天。本報告未經本公司書面許可,不可部份複製。
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for
electronic format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability,
indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention
only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all
their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration,
forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law.
                                         SGS Taiwan Ltd. No.134,WuKungRoad,NewTaipeiIndustrialPark,WukuDistrict,NewTaipeiCity,Taiwan24803/新北市五股區新北產業園區五工路
 134號
                          台灣檢驗科技股份有限公司                                                            t (886-2) 2299-3279                    f (886-2) 2298-0488            www.tw.sgs.com
                                                                                                                                             Member of SGS Group


                                                                                                                                          Report No: ER/2018/C0137
                                                                                                                                          Page: 13 of 37




6.4 Test SET-UP (Block Diagram of Configuration)




6.5 Measurement Procedure:
     1. The EUT was placed on a table which is 0.8m above ground plan.
     2. Maximum procedure was performed on the six highest emissions to ensure EUT
        compliance.
     3. Repeat above procedures until all frequency measured were complete.



6.6 Measurement Result:
    Note: Refer to next page for measurement data and plots.
    Note2: The * reveals the worst-case results that closet to the limit




Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only.
除非另有說明,此報告結果僅對測試之樣品負責,同時此樣品僅保留90天。本報告未經本公司書面許可,不可部份複製。
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for
electronic format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability,
indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention
only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all
their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration,
forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law.
                                         SGS Taiwan Ltd. No.134,WuKungRoad,NewTaipeiIndustrialPark,WukuDistrict,NewTaipeiCity,Taiwan24803/新北市五股區新北產業園區五工路
 134號
                          台灣檢驗科技股份有限公司                                                            t (886-2) 2299-3279                    f (886-2) 2298-0488            www.tw.sgs.com
                                                                                                                                             Member of SGS Group


                                                                                                                                          Report No: ER/2018/C0137
                                                                                                                                          Page: 14 of 37




                               AC POWER LINE CONDUCTED EMISSION TEST DATA




Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only.
除非另有說明,此報告結果僅對測試之樣品負責,同時此樣品僅保留90天。本報告未經本公司書面許可,不可部份複製。
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for
electronic format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability,
indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention
only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all
their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration,
forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law.
                                         SGS Taiwan Ltd. No.134,WuKungRoad,NewTaipeiIndustrialPark,WukuDistrict,NewTaipeiCity,Taiwan24803/新北市五股區新北產業園區五工路
 134號
                          台灣檢驗科技股份有限公司                                                            t (886-2) 2299-3279                    f (886-2) 2298-0488            www.tw.sgs.com
                                                                                                                                             Member of SGS Group


                                                                                                                                          Report No: ER/2018/C0137
                                                                                                                                          Page: 15 of 37




Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only.
除非另有說明,此報告結果僅對測試之樣品負責,同時此樣品僅保留90天。本報告未經本公司書面許可,不可部份複製。
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for
electronic format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability,
indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention
only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all
their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration,
forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law.
                                         SGS Taiwan Ltd. No.134,WuKungRoad,NewTaipeiIndustrialPark,WukuDistrict,NewTaipeiCity,Taiwan24803/新北市五股區新北產業園區五工路
 134號
                          台灣檢驗科技股份有限公司                                                            t (886-2) 2299-3279                    f (886-2) 2298-0488            www.tw.sgs.com
                                                                                                                                             Member of SGS Group


                                                                                                                                          Report No: ER/2018/C0137
                                                                                                                                          Page: 16 of 37




7 RADIATED EMISSION TEST

7.1 Measurement Procedure
          1. The EUT was placed on a turn table which is 0.8m above ground plane.
          2. Maximum procedure was performed on the six highest emissions to ensure EUT
                 compliance.
          3. And also, each emission was to be maximized by changing the polarization of receiving
                 antenna both horizontal and vertical.


7.2 Test SET-UP (Block Diagram of Configuration)
     (A) Radiated Emission Test Set-Up, Frequency Below 30MHz



                     Turntable                                              3m
                                                EUT
                                                                                                                                                           Test
                                                                     0.8 m                                                                                Receiver


                       Ground Plane                                                                     Coaxial Cable


          (B) Radiated Emission Test Set-Up, Frequency Below 1000MHz




                                                                               3m
                                Turntable
                                                           EUT                                                                                         1m to 4m
                    Spectrum
                    Analyzer                                                             0.8m


                             Ground Plane                                                                                  Coaxial Cable




Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only.
除非另有說明,此報告結果僅對測試之樣品負責,同時此樣品僅保留90天。本報告未經本公司書面許可,不可部份複製。
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for
electronic format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability,
indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention
only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all
their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration,
forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law.
                                         SGS Taiwan Ltd. No.134,WuKungRoad,NewTaipeiIndustrialPark,WukuDistrict,NewTaipeiCity,Taiwan24803/新北市五股區新北產業園區五工路
 134號
                          台灣檢驗科技股份有限公司                                                            t (886-2) 2299-3279                    f (886-2) 2298-0488            www.tw.sgs.com
                                                                                                                                             Member of SGS Group


                                                                                                                                          Report No: ER/2018/C0137
                                                                                                                                          Page: 17 of 37




7.3 Measurement Equipment Used:
             EQUIPMENT                                                               MODEL                        SERIAL
                                                           MFR                                                           LAST CAL. CAL DUE.
                  TYPE                                                              NUMBER                       NUMBER
             Bi-log Antenna                     SCHWAZBECK                          VULB9168                       378   12/29/2017 12/28/2018
             Loop Antenna                       ETS.LINDGREN                              6502                      148045               10/08/2018 10/07/2019
           3m Site NSA       SGS      966 chamber     N/A    01/02/2018 01/01/2019
         Spectrum Analyzer  Agilent     E4446A    MY51100003 05/15/2018 05/14/2019
         EMI Test Receiver   R&S         ESCI7      100335   02/02/2018 02/01/2019
           Pre-Amplifier      HP         8447D    2944A07676 01/02/2018 01/01/2019
          Low Loss Cable Huber Suhner   966_RX         9     01/02/2018 01/01/2019


7.4 Field Strength Calculation
     The field strength is calculated by adding the Antenna Factor and Cable Factor and
     subtracting the Amplifier Gain and Duty Cycle Correction Factor (if any) from the measured
     reading. The basic equation with a sample calculation is as follows:
                               FS = RA + AF + CL - AG

          Where               FS = Field Strength                                                  CL = Cable Attenuation Factor (Cable
                                                                                                   Loss)
                            RA = Reading Amplitude                                                 AG = Amplifier Gain
                            AF = Antenna Factor




Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only.
除非另有說明,此報告結果僅對測試之樣品負責,同時此樣品僅保留90天。本報告未經本公司書面許可,不可部份複製。
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for
electronic format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability,
indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention
only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all
their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration,
forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law.
                                         SGS Taiwan Ltd. No.134,WuKungRoad,NewTaipeiIndustrialPark,WukuDistrict,NewTaipeiCity,Taiwan24803/新北市五股區新北產業園區五工路
 134號
                          台灣檢驗科技股份有限公司                                                            t (886-2) 2299-3279                    f (886-2) 2298-0488            www.tw.sgs.com
                                                                                                                                             Member of SGS Group


                                                                                                                                          Report No: ER/2018/C0137
                                                                                                                                          Page: 18 of 37




7.5 Field Strength of Fundamental Emission
7.5.1 Limit
    Field strength of fundamental emissions limit:
    The field strength of fundamental emissions shall not exceed 15848 micorvolts/meter at 30
    meters. The Limit is converted to 123.90dBuV/m by offsetting the distance extrapolation
    factor as measurement distance is taken place at 3 meters.

                    Distance extrapolation = 40 *log (30/3) = 40 dB

       Limit is re-adjusted in terms of limit taken in 3m = 20 *log (15848 uV/m) + 40 =
       124.00dBuV/m

       Note:
       Actual FS(dBµV/m) = Spectrum. Reading level(dBµV) + Factor(dB)
       Factor(dB) = Antenna Factor(dBµV/m) + Cable Loss(dB) – Pre_Amplifier Gain(dB)

       The trace on RE(radiation emission) plot is as colored blue, and the detection manner we’ve
       employed is peak detector.




Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only.
除非另有說明,此報告結果僅對測試之樣品負責,同時此樣品僅保留90天。本報告未經本公司書面許可,不可部份複製。
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for
electronic format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability,
indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention
only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all
their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration,
forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law.
                                         SGS Taiwan Ltd. No.134,WuKungRoad,NewTaipeiIndustrialPark,WukuDistrict,NewTaipeiCity,Taiwan24803/新北市五股區新北產業園區五工路
 134號
                          台灣檢驗科技股份有限公司                                                            t (886-2) 2299-3279                    f (886-2) 2298-0488            www.tw.sgs.com
                                                                                                                                             Member of SGS Group


                                                                                                                                          Report No: ER/2018/C0137
                                                                                                                                          Page: 19 of 37




7.5.2 Field Strength of Fundamental Emission Measurement Result

Operation Band                                  :NFC                                                           Test Date                                             :2018-11-01
Fundamental Frequency                           :13.56 MHz                                                     Temp./Humi.                                           :21 deg_C / 62 RH
Operation Mode                                  :MAIN                                                          Engineer                                              :Wei
EUT Pol.                                        :H Plane                                                       Measurement Antenna Pol.                              :VERTICAL




       Freq.                  Detector                  Spectrum                         Factor                   Actual                   Limit                     Margin
                               Mode                   Reading Level                                                FS                      @3m
       MHz                   PK/QP/AV                     dBµV                             dB                    dBµV/m                   dBµV/m                       dB
       13.56                   Peak                      43.98                            11.52                   55.50                   123.90                     -68.40




Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only.
除非另有說明,此報告結果僅對測試之樣品負責,同時此樣品僅保留90天。本報告未經本公司書面許可,不可部份複製。
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for
electronic format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability,
indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention
only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all
their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration,
forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law.
                                         SGS Taiwan Ltd. No.134,WuKungRoad,NewTaipeiIndustrialPark,WukuDistrict,NewTaipeiCity,Taiwan24803/新北市五股區新北產業園區五工路
 134號
                          台灣檢驗科技股份有限公司                                                            t (886-2) 2299-3279                    f (886-2) 2298-0488            www.tw.sgs.com
                                                                                                                                             Member of SGS Group


                                                                                                                                          Report No: ER/2018/C0137
                                                                                                                                          Page: 20 of 37




Operation Band                                  :NFC                                                           Test Date                                             :2018-11-01
Fundamental Frequency                           :13.56 MHz                                                     Temp./Humi.                                           :24.1 deg_C / 65 RH
Operation Mode                                  :MAIN                                                          Engineer                                              :Wei
EUT Pol.                                        :H Plane                                                       Measurement Antenna Pol.                              :HORIZONTAL




       Freq.                  Detector                  Spectrum                         Factor                   Actual                   Limit                     Margin
                               Mode                   Reading Level                                                FS                      @3m
       MHz                   PK/QP/AV                     dBµV                             dB                    dBµV/m                   dBµV/m                       dB
       13.56                   Peak                      43.47                            11.52                   54.99                   123.90                     -68.91




Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only.
除非另有說明,此報告結果僅對測試之樣品負責,同時此樣品僅保留90天。本報告未經本公司書面許可,不可部份複製。
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for
electronic format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability,
indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention
only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all
their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration,
forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law.
                                         SGS Taiwan Ltd. No.134,WuKungRoad,NewTaipeiIndustrialPark,WukuDistrict,NewTaipeiCity,Taiwan24803/新北市五股區新北產業園區五工路
 134號
                          台灣檢驗科技股份有限公司                                                            t (886-2) 2299-3279                    f (886-2) 2298-0488            www.tw.sgs.com
                                                                                                                                             Member of SGS Group


                                                                                                                                          Report No: ER/2018/C0137
                                                                                                                                          Page: 21 of 37




7.5.3 Radiated Mask
        (a) 15.848 millivolts/m (84 dBμV/m) at 30 m, within the band 13.553-13.567 MHz.
        (b) 334 microvolts/m (50.5 dBμV/m) at 30 m, within the bands 13.410-13.553 MHz and
          13.567-13.710 MHz.
        (c) 106 microvolts/m (40.5 dBμV/m) at 30 m, within the bands 13.110-13.410 MHz and
          13.710-14.010 MHz.

             Distance extrapolation = 40 *log (30/3) = 40 dB

             Limit is re-adjusted in terms of limit taken in 3m for the following frequency segment of the
             interest:
                  a) 20 *log (15848uV/m) + 40dB = 124.00dBuV/m
                  b) 20 *log(334uV/m) + 40dB = 90.47dBuV/m
                  c) 20*log(106uV/m) + 40dB = 80.50dBuV/m




Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only.
除非另有說明,此報告結果僅對測試之樣品負責,同時此樣品僅保留90天。本報告未經本公司書面許可,不可部份複製。
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for
electronic format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability,
indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention
only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all
their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration,
forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law.
                                         SGS Taiwan Ltd. No.134,WuKungRoad,NewTaipeiIndustrialPark,WukuDistrict,NewTaipeiCity,Taiwan24803/新北市五股區新北產業園區五工路
 134號
                          台灣檢驗科技股份有限公司                                                            t (886-2) 2299-3279                    f (886-2) 2298-0488            www.tw.sgs.com
                                                                                                                                             Member of SGS Group


                                                                                                                                          Report No: ER/2018/C0137
                                                                                                                                          Page: 22 of 37




Operation Band                                  :NFC                                                           Test Date                                             :2018-11-01
Fundamental Frequency                           :13.56 MHz                                                     Temp./Humi.                                           :24.1 deg_C / 65 RH
Operation Mode                                  :MASK                                                          Engineer                                              :Wei
EUT Pol.                                        :H Plane                                                       Measurement Antenna Pol.                              :VERTICAL




       Freq.                  Detector                  Spectrum                         Factor                   Actual                   Limit                     Margin
                               Mode                   Reading Level                                                FS                      @3m
       MHz                   PK/QP/AV                     dBµV                             dB                    dBµV/m                   dBµV/m                       dB
       13.35                   Peak                      26.59                            11.52                   38.11                    80.50                     -42.39
       13.55                   Peak                      38.75                            11.52                   50.27                    90.47                     -40.20
       13.57                   Peak                      39.63                            11.52                   51.15                    90.47                     -39.32
       13.77                   Peak                      25.75                            11.53                   37.28                    80.50                     -43.22




Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only.
除非另有說明,此報告結果僅對測試之樣品負責,同時此樣品僅保留90天。本報告未經本公司書面許可,不可部份複製。
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for
electronic format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability,
indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention
only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all
their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration,
forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law.
                                         SGS Taiwan Ltd. No.134,WuKungRoad,NewTaipeiIndustrialPark,WukuDistrict,NewTaipeiCity,Taiwan24803/新北市五股區新北產業園區五工路
 134號
                          台灣檢驗科技股份有限公司                                                            t (886-2) 2299-3279                    f (886-2) 2298-0488            www.tw.sgs.com
                                                                                                                                             Member of SGS Group


                                                                                                                                          Report No: ER/2018/C0137
                                                                                                                                          Page: 23 of 37




Operation Band                                  :NFC                                                           Test Date                                             :2018-11-01
Fundamental Frequency                           :13.56 MHz                                                     Temp./Humi.                                           :24.1 deg_C / 65 RH
Operation Mode                                  :MASK                                                          Engineer                                              :Wei
EUT Pol.                                        :H Plane                                                       Measurement Antenna Pol.                              :HORIZONTAL




       Freq.                  Detector                  Spectrum                         Factor                   Actual                   Limit                     Margin
                               Mode                   Reading Level                                                FS                      @3m
       MHz                   PK/QP/AV                     dBµV                             dB                    dBµV/m                   dBµV/m                       dB
       13.35                   Peak                      23.87                            11.52                   35.39                    80.50                     -45.11
       13.55                   Peak                      38.16                            11.52                   49.68                    90.47                     -40.79
       13.57                   Peak                      39.00                            11.52                   50.52                    90.47                     -39.95
       13.77                   Peak                      24.10                            11.53                   35.63                    80.50                     -44.87




Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only.
除非另有說明,此報告結果僅對測試之樣品負責,同時此樣品僅保留90天。本報告未經本公司書面許可,不可部份複製。
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for
electronic format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability,
indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention
only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all
their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration,
forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law.
                                         SGS Taiwan Ltd. No.134,WuKungRoad,NewTaipeiIndustrialPark,WukuDistrict,NewTaipeiCity,Taiwan24803/新北市五股區新北產業園區五工路
 134號
                          台灣檢驗科技股份有限公司                                                            t (886-2) 2299-3279                    f (886-2) 2298-0488            www.tw.sgs.com
                                                                                                                                             Member of SGS Group


                                                                                                                                          Report No: ER/2018/C0137
                                                                                                                                          Page: 24 of 37




7.5.4 Radiated Emission –
       Limit:
       §15.225
        (d) 30 microvolts/m (29.4 dBμV/m) at 30 m, outside the band 13.110-14.010 MHz.
       Limit is converted by adding the distance extrapolation factor as the measurement
 distance
          was taken place at 3m.
       §RSS-210 A2.6

               (d) The field strength of any emissions appearing outside of the 13.110-14.010 MHz band
               shall not exceed the general radiated emission limits in § 15.209.

                      a) 20*log(30uV/m) + 40dB = 69.54 dBuV/m




Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only.
除非另有說明,此報告結果僅對測試之樣品負責,同時此樣品僅保留90天。本報告未經本公司書面許可,不可部份複製。
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for
electronic format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability,
indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention
only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all
their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration,
forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law.
                                         SGS Taiwan Ltd. No.134,WuKungRoad,NewTaipeiIndustrialPark,WukuDistrict,NewTaipeiCity,Taiwan24803/新北市五股區新北產業園區五工路
 134號
                          台灣檢驗科技股份有限公司                                                            t (886-2) 2299-3279                    f (886-2) 2298-0488            www.tw.sgs.com
                                                                                                                                             Member of SGS Group


                                                                                                                                          Report No: ER/2018/C0137
                                                                                                                                          Page: 25 of 37




Operation Band                                  :NFC                                                           Test Date                                             :2018-11-01
Fundamental Frequency                           :13.56 MHz                                                     Temp./Humi.                                           :24.1 deg_C / 65 RH
Operation Mode                                  :Tx                                                            Engineer                                              :Wei
EUT Pol.                                        :H Plane                                                       Measurement Antenna Pol.                              :VERTICAL




       Freq.                  Detector                  Spectrum                         Factor                   Actual                   Limit                     Margin
                               Mode                   Reading Level                                                FS                      @3m
       MHz                   PK/QP/AV                     dBµV                            dB                     dBµV/m                   dBµV/m                       dB
       12.60                   Peak                      15.31                           11.50                    26.81                    69.54                     -42.73
       18.44                   Peak                      18.83                           11.64                    30.47                    69.54                     -39.07
       19.14                   Peak                      14.26                           11.65                    25.91                    69.54                     -43.63
       23.00                   Peak                      19.52                           10.86                    30.38                    69.54                     -39.16
       24.16                   Peak                      20.28                           10.58                    30.86                    69.54                     -38.68
       27.12                   Peak                      10.64                           9.94                     20.58                    69.54                     -48.96
       28.64                   Peak                      18.12                           9.62                     27.74                    69.54                     -41.80




Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only.
除非另有說明,此報告結果僅對測試之樣品負責,同時此樣品僅保留90天。本報告未經本公司書面許可,不可部份複製。
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for
electronic format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability,
indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention
only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all
their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration,
forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law.
                                         SGS Taiwan Ltd. No.134,WuKungRoad,NewTaipeiIndustrialPark,WukuDistrict,NewTaipeiCity,Taiwan24803/新北市五股區新北產業園區五工路
 134號
                          台灣檢驗科技股份有限公司                                                            t (886-2) 2299-3279                    f (886-2) 2298-0488            www.tw.sgs.com
                                                                                                                                             Member of SGS Group


                                                                                                                                          Report No: ER/2018/C0137
                                                                                                                                          Page: 26 of 37




Operation Band                                  :NFC                                                           Test Date                                             :2018-11-01
Fundamental Frequency                           :13.56 MHz                                                     Temp./Humi.                                           :24.1 deg_C / 65 RH
Operation Mode                                  :Tx                                                            Engineer                                              :Wei
EUT Pol.                                        :H Plane                                                       Measurement Antenna Pol.                              :HORIZONTAL




       Freq.                  Detector                  Spectrum                         Factor                   Actual                   Limit                     Margin
                               Mode                   Reading Level                                                FS                      @3m
       MHz                   PK/QP/AV                     dBµV                            dB                     dBµV/m                   dBµV/m                       dB
       12.94                   Peak                      12.62                           11.51                    24.13                    69.54                     -45.41
       18.40                   Peak                      12.41                           11.64                    24.05                    69.54                     -45.49
       19.30                   Peak                      10.96                           11.65                    22.61                    69.54                     -46.93
       22.80                   Peak                      11.68                           10.91                    22.59                    69.54                     -46.95
       23.86                   Peak                      11.93                           10.66                    22.59                    69.54                     -46.95
       27.12                   Peak                      10.66                           9.94                     20.60                    69.54                     -48.94
       28.64                   Peak                      16.98                           9.62                     26.60                    69.54                     -42.94




Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only.
除非另有說明,此報告結果僅對測試之樣品負責,同時此樣品僅保留90天。本報告未經本公司書面許可,不可部份複製。
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for
electronic format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability,
indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention
only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all
their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration,
forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law.
                                         SGS Taiwan Ltd. No.134,WuKungRoad,NewTaipeiIndustrialPark,WukuDistrict,NewTaipeiCity,Taiwan24803/新北市五股區新北產業園區五工路
 134號
                          台灣檢驗科技股份有限公司                                                            t (886-2) 2299-3279                    f (886-2) 2298-0488            www.tw.sgs.com
                                                                                                                                             Member of SGS Group


                                                                                                                                          Report No: ER/2018/C0137
                                                                                                                                          Page: 27 of 37




Operation Band                                  :NFC                                                           Test Date                                             :2018-11-01
Fundamental Frequency                           :13.56 MHz                                                     Temp./Humi.                                           :24.1 deg_C / 65 RH
Operation Mode                                  :Tx                                                            Engineer                                              :Wei
EUT Pol.                                        :H Plane                                                       Measurement Antenna Pol.                              :VERTICAL




       Freq.                  Detector                  Spectrum                         Factor                   Actual                   Limit                     Margin
                               Mode                   Reading Level                                                FS                      @3m
       MHz                   PK/QP/AV                     dBµV                             dB                    dBµV/m                   dBµV/m                       dB
       47.46                   Peak                      32.00                            -7.64                   24.36                    40.00                     -15.64
      262.80                   Peak                      33.48                            -6.91                   26.57                    46.00                     -19.43
      327.79                   Peak                      35.66                            -4.99                   30.67                    46.00                     -15.33
      371.44                   Peak                      32.33                            -3.97                   28.36                    46.00                     -17.64
      393.75                   Peak                      36.19                            -3.42                   32.77                    46.00                     -13.23
      458.74                   Peak                      29.43                            -2.44                   26.99                    46.00                     -19.01




Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only.
除非另有說明,此報告結果僅對測試之樣品負責,同時此樣品僅保留90天。本報告未經本公司書面許可,不可部份複製。
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for
electronic format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability,
indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention
only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all
their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration,
forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law.
                                         SGS Taiwan Ltd. No.134,WuKungRoad,NewTaipeiIndustrialPark,WukuDistrict,NewTaipeiCity,Taiwan24803/新北市五股區新北產業園區五工路
 134號
                          台灣檢驗科技股份有限公司                                                            t (886-2) 2299-3279                    f (886-2) 2298-0488            www.tw.sgs.com
                                                                                                                                             Member of SGS Group


                                                                                                                                          Report No: ER/2018/C0137
                                                                                                                                          Page: 28 of 37




Operation Band                                  :NFC                                                           Test Date                                             :2018-11-01
Fundamental Frequency                           :13.56 MHz                                                     Temp./Humi.                                           :24.1 deg_C / 65 RH
Operation Mode                                  :Tx                                                            Engineer                                              :Wei
EUT Pol.                                        :H Plane                                                       Measurement Antenna Pol.                              :HORIZONTAL




       Freq.                  Detector                  Spectrum                         Factor                   Actual                   Limit                     Margin
                               Mode                   Reading Level                                                FS                      @3m
       MHz                   PK/QP/AV                     dBµV                             dB                    dBµV/m                   dBµV/m                       dB
       59.10                   Peak                      29.03                            -7.77                   21.26                    40.00                     -18.74
      158.04                   Peak                      28.09                            -7.17                   20.92                    43.50                     -22.58
      318.09                   Peak                      27.37                            -5.11                   22.26                    46.00                     -23.74
      367.56                   Peak                      28.14                            -4.01                   24.13                    46.00                     -21.87
      449.04                   Peak                      28.85                            -2.72                   26.13                    46.00                     -19.87
      524.70                   Peak                      28.52                            -1.56                   26.96                    46.00                     -19.04




Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only.
除非另有說明,此報告結果僅對測試之樣品負責,同時此樣品僅保留90天。本報告未經本公司書面許可,不可部份複製。
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for
electronic format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability,
indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention
only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all
their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration,
forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law.
                                         SGS Taiwan Ltd. No.134,WuKungRoad,NewTaipeiIndustrialPark,WukuDistrict,NewTaipeiCity,Taiwan24803/新北市五股區新北產業園區五工路
 134號
                          台灣檢驗科技股份有限公司                                                            t (886-2) 2299-3279                    f (886-2) 2298-0488            www.tw.sgs.com
                                                                                                                                             Member of SGS Group


                                                                                                                                          Report No: ER/2018/C0137
                                                                                                                                          Page: 29 of 37




8 FREQUENCY TOLERANCE

8.1 Measurement Procedure
          1. The EUT was placed on a turn table which is 0.8m above ground plane.
          2. Set EUT as normal operation
          3. Set SPA Center Frequency = fundamental frequency, RBW, VBW= 10kHz, Span
                 =100kHz.
          4. Set SPA Max hold. Mark peak.

8.2 Test SET-UP (Block Diagram of Configuration)

                                                                                               Temperature Chamber



                                                                                       Antenna


                             Spectrum analyzer                                                                                 EUT




                                                                                                                   DC Power Supply

8.3 Measurement Equipment Used:
             EQUIPMENT                                                              MODEL                         SERIAL
                                                        MFR                                                                              LAST CAL. CAL DUE.
               TYPE                                                                NUMBER                        NUMBER
           Loop Antenna ETS.LINDGREN    6502       148045   10/08/2018 10/07/2019
           EXA Spectrum
                            Agilent   N9010A     MY50420195 05/03/2018 05/02/2019
             Analyzer
           Coaxial Cables    N/A     WK CE Cable    N/A     01/02/2018 01/01/2019




Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only.
除非另有說明,此報告結果僅對測試之樣品負責,同時此樣品僅保留90天。本報告未經本公司書面許可,不可部份複製。
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for
electronic format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability,
indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention
only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all
their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration,
forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law.
                                         SGS Taiwan Ltd. No.134,WuKungRoad,NewTaipeiIndustrialPark,WukuDistrict,NewTaipeiCity,Taiwan24803/新北市五股區新北產業園區五工路
 134號
                          台灣檢驗科技股份有限公司                                                            t (886-2) 2299-3279                    f (886-2) 2298-0488            www.tw.sgs.com
                                                                                                                                             Member of SGS Group


                                                                                                                                          Report No: ER/2018/C0137
                                                                                                                                          Page: 30 of 37




8.4 Measurement Results
Startup:
               A. Temperature Variation

                          Power Supply                            Environment                    Frequency
                                                                                                                             Delta (Hz)                   Limit (KHz)
                             Vdc                                Temperature (℃)                    (MHz)
                              3.8                                      -20                       13.5599991                   4.90000                       +/- 1.356
                              3.8                                      -10                       13.5600072                   -3.20000                      +/- 1.356
                              3.8                                       0                        13.5600069                   -2.90000                      +/- 1.356
                              3.8                                      10                        13.5599901                   13.90000                      +/- 1.356
                              3.8                                      20                        13.560004                    0.00000                       +/- 1.356
                              3.8                                      30                        13.5600097                   -5.70000                      +/- 1.356
                              3.8                                      40                        13.5599973                   6.70000                       +/- 1.356
                              3.8                                      50                        13.5600059                   -1.90000                      +/- 1.356


               B. Supply Voltage Variation

                          Power Supply                            Environment                    Frequency
                                                                                                                             Delta (Hz)                   Limit (KHz)
                             Vdc                                Temperature (℃ )                   (MHz)
                             4.37                                      20                        13.5599925                   11.50000                      +/- 1.356
                              3.8                                      20                        13.560004                    0.00000                       +/- 1.356
                             3.23                                      20                        13.5600006                   3.40000                       +/- 1.356




Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only.
除非另有說明,此報告結果僅對測試之樣品負責,同時此樣品僅保留90天。本報告未經本公司書面許可,不可部份複製。
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for
electronic format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability,
indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention
only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all
their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration,
forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law.
                                         SGS Taiwan Ltd. No.134,WuKungRoad,NewTaipeiIndustrialPark,WukuDistrict,NewTaipeiCity,Taiwan24803/新北市五股區新北產業園區五工路
 134號
                          台灣檢驗科技股份有限公司                                                            t (886-2) 2299-3279                    f (886-2) 2298-0488            www.tw.sgs.com
                                                                                                                                             Member of SGS Group


                                                                                                                                          Report No: ER/2018/C0137
                                                                                                                                          Page: 31 of 37




2 Minutes:
               A. Temperature Variation

                          Power Supply                            Environment                    Frequency
                                                                                                                             Delta (Hz)                   Limit (KHz)
                             Vdc                                Temperature (℃)                    (MHz)
                              3.8                                      -20                       13.5599936                    1.50000                      +/- 1.356
                              3.8                                      -10                       13.5600077                   -12.60000                     +/- 1.356
                              3.8                                       0                        13.5600022                    -7.10000                     +/- 1.356
                              3.8                                      10                        13.5599987                    -3.60000                     +/- 1.356
                              3.8                                      20                        13.5599951                    0.00000                      +/- 1.356
                              3.8                                      30                        13.559991                     4.10000                      +/- 1.356
                              3.8                                      40                        13.5600049                    -9.80000                     +/- 1.356
                              3.8                                      50                        13.5600069                   -11.80000                     +/- 1.356


               B. Supply Voltage Variation

                          Power Supply                            Environment                    Frequency
                                                                                                                             Delta (Hz)                   Limit (KHz)
                             Vdc                                Temperature (℃ )                   (MHz)
                             4.37                                      20                        13.5599945                    9.50000                      +/- 1.356
                              3.8                                      20                        13.560004                     0.00000                      +/- 1.356
                             3.23                                      20                        13.5600095                    -5.50000                     +/- 1.356




Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only.
除非另有說明,此報告結果僅對測試之樣品負責,同時此樣品僅保留90天。本報告未經本公司書面許可,不可部份複製。
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for
electronic format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability,
indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention
only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all
their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration,
forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law.
                                         SGS Taiwan Ltd. No.134,WuKungRoad,NewTaipeiIndustrialPark,WukuDistrict,NewTaipeiCity,Taiwan24803/新北市五股區新北產業園區五工路
 134號
                          台灣檢驗科技股份有限公司                                                            t (886-2) 2299-3279                    f (886-2) 2298-0488            www.tw.sgs.com
                                                                                                                                             Member of SGS Group


                                                                                                                                          Report No: ER/2018/C0137
                                                                                                                                          Page: 32 of 37




5 Minutes:
               A. Temperature Variation

                          Power Supply                            Environment                    Frequency
                                                                                                                             Delta (Hz)                   Limit (KHz)
                             Vdc                                Temperature (℃)                    (MHz)
                              3.8                                      -20                       13.5599941                    6.50000                      +/- 1.356
                              3.8                                      -10                       13.5600092                    -8.60000                     +/- 1.356
                              3.8                                       0                           13.56                      0.60000                      +/- 1.356
                              3.8                                      10                        13.5599995                    1.10000                      +/- 1.356
                              3.8                                      20                        13.5600006                    0.00000                      +/- 1.356
                              3.8                                      30                        13.5599995                    1.10000                      +/- 1.356
                              3.8                                      40                        13.5599922                    8.40000                      +/- 1.356
                              3.8                                      50                        13.5600086                    -8.00000                     +/- 1.356


               B. Supply Voltage Variation

                          Power Supply                            Environment                    Frequency
                                                                                                                             Delta (Hz)                   Limit (KHz)
                             Vdc                                Temperature (℃ )                   (MHz)
                             4.37                                      20                        13.5599931                   10.90000                      +/- 1.356
                              3.8                                      20                        13.560004                    0.00000                       +/- 1.356
                             3.23                                      20                        13.5599972                   6.80000                       +/- 1.356




Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only.
除非另有說明,此報告結果僅對測試之樣品負責,同時此樣品僅保留90天。本報告未經本公司書面許可,不可部份複製。
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for
electronic format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability,
indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention
only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all
their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration,
forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law.
                                         SGS Taiwan Ltd. No.134,WuKungRoad,NewTaipeiIndustrialPark,WukuDistrict,NewTaipeiCity,Taiwan24803/新北市五股區新北產業園區五工路
 134號
                          台灣檢驗科技股份有限公司                                                            t (886-2) 2299-3279                    f (886-2) 2298-0488            www.tw.sgs.com
                                                                                                                                             Member of SGS Group


                                                                                                                                          Report No: ER/2018/C0137
                                                                                                                                          Page: 33 of 37




10 Minutes:
               A. Temperature Variation

                          Power Supply                            Environment                    Frequency
                                                                                                                             Delta (Hz)                   Limit (KHz)
                             Vdc                                Temperature (℃)                    (MHz)
                              3.8                                      -20                       13.5600068                   -13.10000                     +/- 1.356
                              3.8                                      -10                       13.5599973                    -3.60000                     +/- 1.356
                              3.8                                       0                        13.5600067                   -13.00000                     +/- 1.356
                              3.8                                      10                        13.5599956                    -1.90000                     +/- 1.356
                              3.8                                      20                        13.5599937                    0.00000                      +/- 1.356
                              3.8                                      30                        13.5599921                    1.60000                      +/- 1.356
                              3.8                                      40                        13.5599919                    1.80000                      +/- 1.356
                              3.8                                      50                        13.5600066                   -12.90000                     +/- 1.356


               B. Supply Voltage Variation

                          Power Supply                            Environment                    Frequency
                                                                                                                             Delta (Hz)                   Limit (KHz)
                             Vdc                                Temperature (℃ )                   (MHz)
                             4.37                                      20                        13.5599985                   5.50000                       +/- 1.356
                              3.8                                      20                        13.560004                    0.00000                       +/- 1.356
                             3.23                                      20                        13.5599928                   11.20000                      +/- 1.356




Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only.
除非另有說明,此報告結果僅對測試之樣品負責,同時此樣品僅保留90天。本報告未經本公司書面許可,不可部份複製。
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for
electronic format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability,
indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention
only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all
their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration,
forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law.
                                         SGS Taiwan Ltd. No.134,WuKungRoad,NewTaipeiIndustrialPark,WukuDistrict,NewTaipeiCity,Taiwan24803/新北市五股區新北產業園區五工路
 134號
                          台灣檢驗科技股份有限公司                                                            t (886-2) 2299-3279                    f (886-2) 2298-0488            www.tw.sgs.com
                                                                                                                                             Member of SGS Group


                                                                                                                                          Report No: ER/2018/C0137
                                                                                                                                          Page: 34 of 37




9 20 dB OCCUPIED BANDWIDTH MEASUREMENT
9.1 Standard Applicable:
     §2.1049 & §15.215 (c)
9.2 Limit:
     None
9.3 Test Set-up
     Refer to section 6.2 in this report
9.4 Measurement Procedure
     20dB bandwidth
     1. The transmitter output (antenna port) was connected to the spectrum analyzer in peak
         mode.
     2. 20dB Bandwidth the resolution bandwidth of 1 kHz and the video bandwidth of 3 kHz
        were used.
     3. Measured the spectrum width with power higher than 20dB below carrier.
9.5 Measurement Equipment Used:
     Refer to section 8.3 in this report
9.6 Measurement Result
                            20dB BW (kHz)                               Opration range                 Frequency (MHz)                       Limit (MHz)
                                 2.7                                         Low                          13.55885                             >13.11
                                                                             High                         13.56130                             <14.01
-20dB Bandwidth




Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only.
除非另有說明,此報告結果僅對測試之樣品負責,同時此樣品僅保留90天。本報告未經本公司書面許可,不可部份複製。
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for
electronic format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability,
indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention
only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all
their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration,
forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law.
                                         SGS Taiwan Ltd. No.134,WuKungRoad,NewTaipeiIndustrialPark,WukuDistrict,NewTaipeiCity,Taiwan24803/新北市五股區新北產業園區五工路
 134號
                          台灣檢驗科技股份有限公司                                                            t (886-2) 2299-3279                    f (886-2) 2298-0488            www.tw.sgs.com
                                                                                                                                             Member of SGS Group


                                                                                                                                          Report No: ER/2018/C0137
                                                                                                                                          Page: 35 of 37




Operation range low




Operation range High




Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only.
除非另有說明,此報告結果僅對測試之樣品負責,同時此樣品僅保留90天。本報告未經本公司書面許可,不可部份複製。
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for
electronic format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability,
indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention
only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all
their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration,
forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law.
                                         SGS Taiwan Ltd. No.134,WuKungRoad,NewTaipeiIndustrialPark,WukuDistrict,NewTaipeiCity,Taiwan24803/新北市五股區新北產業園區五工路
 134號
                          台灣檢驗科技股份有限公司                                                            t (886-2) 2299-3279                    f (886-2) 2298-0488            www.tw.sgs.com
                                                                                                                                             Member of SGS Group


                                                                                                                                          Report No: ER/2018/C0137
                                                                                                                                          Page: 36 of 37




Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only.
除非另有說明,此報告結果僅對測試之樣品負責,同時此樣品僅保留90天。本報告未經本公司書面許可,不可部份複製。
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for
electronic format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability,
indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention
only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all
their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration,
forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law.
                                         SGS Taiwan Ltd. No.134,WuKungRoad,NewTaipeiIndustrialPark,WukuDistrict,NewTaipeiCity,Taiwan24803/新北市五股區新北產業園區五工路
 134號
                          台灣檢驗科技股份有限公司                                                            t (886-2) 2299-3279                    f (886-2) 2298-0488            www.tw.sgs.com
                                                                                                                                             Member of SGS Group


                                                                                                                                          Report No: ER/2018/C0137
                                                                                                                                          Page: 37 of 37




10 ANTENNA REQUIREMENT

10.1 Standard Applicable:
   According to §15.203, Antenna requirement.
   An intentional radiator shall be designed to ensure that no antenna other than that furnished
   by the responsible party shall be used with the device. The use of a permanently attached
   antenna or of an antenna that uses a unique coupling to the intentional radiator shall be
   considered sufficient to comply with the provisions of this Section. The manufacturer may
   design the unit so that a broken antenna can be replaced by the user, but the use of a
   standard antenna jack or electrical connector is prohibited. This requirement does not apply
   to carrier current devices or to devices operated under the provisions of Sections 15.211,
   15.213, 15.217, 15.219, or 15.221. Further, this requirement does not apply to intentional
   radiators that must be professionally installed, such as perimeter protection systems and
   some field disturbance sensors, or to other intentional radiators which, in accordance with
   Section 15.31(d), must be measured at the installation site. However, the installer shall be
   responsible for ensuring that the proper antenna is employed so that the limits in this Part are
   not exceeded.

10.2 Antenna Connected Construction:
   The antenna is designed as permanently attached and no consideration of replacement.
   Please see EUT photo for details.


                                                                             ~ End of Report ~




Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only.
除非另有說明,此報告結果僅對測試之樣品負責,同時此樣品僅保留90天。本報告未經本公司書面許可,不可部份複製。
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for
electronic format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability,
indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention
only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all
their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration,
forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law.
                                         SGS Taiwan Ltd. No.134,WuKungRoad,NewTaipeiIndustrialPark,WukuDistrict,NewTaipeiCity,Taiwan24803/新北市五股區新北產業園區五工路
 134號
                          台灣檢驗科技股份有限公司                                                            t (886-2) 2299-3279                    f (886-2) 2298-0488            www.tw.sgs.com
                                                                                                                                             Member of SGS Group



Document Created: 2019-01-08 10:59:38
Document Modified: 2019-01-08 10:59:38

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC