03 FCC SAR Report_8

FCC ID: AK8UTXB40

RF Exposure Info

Download: PDF
FCCID_4411524

                                                      Test report No.   :   12803138H-D
                                                      Page              :   126 of 134
                                                      FCC ID            :   AK8UTXB40
                                                      Issued date       :   July 22, 2019




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone: +81 596 24 8999
Facsimile: +81 596 24 8124


                                                      Test report No.   :   12803138H-D
                                                      Page              :   127 of 134
                                                      FCC ID            :   AK8UTXB40
                                                      Issued date       :   July 22, 2019




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone: +81 596 24 8999
Facsimile: +81 596 24 8124


                                                      Test report No.   :   12803138H-D
                                                      Page              :   128 of 134
                                                      FCC ID            :   AK8UTXB40
                                                      Issued date       :   July 22, 2019




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone: +81 596 24 8999
Facsimile: +81 596 24 8124


                                                      Test report No.   :   12803138H-D
                                                      Page              :   129 of 134
                                                      FCC ID            :   AK8UTXB40
                                                      Issued date       :   July 22, 2019




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone: +81 596 24 8999
Facsimile: +81 596 24 8124


                                                                                           Test report No.   :   12803138H-D
                                                                                           Page              :   130 of 134
                                                                                           FCC ID            :   AK8UTXB40
                                                                                           Issued date       :   July 22, 2019



             System check uncertainty

The uncertainty budget has been determined for the DASY5 measurement system according to the SPEAG documents and
is given in the following Table.
Repeatability Budget for System Check
<0.3 – 3GHz range Body>
                          Uncertainty   Probability              (ci)   Standard    vi
Error Description         value ± %     distribution   divisor   1g     (1g)        or
                                                                                    veff
Measurement System
Probe calibration           ± 1.8       Normal         1         1        ± 1.8     ∞
Axial isotropy of
                            ± 0.0       Rectangular    √3        1        ± 0.0     ∞
the probe
Spherical isotropy of
                            ± 0.0       Rectangular    √3        1        ± 0.0     ∞
the probe
Boundary effects            ±   0.0     Rectangular    √3        1        ±   0.0   ∞
Probe linearity             ±   0.0     Rectangular    √3        1        ±   0.0   ∞
Detection limit             ±   0.0     Rectangular    √3        1        ±   0.0   ∞
Modulation response         ±   0.0     Rectangular    √3        1        ±   0.0   ∞
Readout electronics         ±   0.0     Normal         1         1        ±   0.0   ∞
Response time               ±   0.0     Rectangular    √3        1        ±   0.0   ∞
Integration time            ±   0.0     Rectangular    √3        1        ±   0.0   ∞
RF ambient Noise            ±   0.0     Rectangular    √3        1        ±   0.0   ∞
RF ambient Reflections      ±   0.0     Rectangular    √3        1        ±   0.0   ∞
Probe Positioner            ±   0.4     Rectangular    √3        1        ±   0.2   ∞
Probe positioning           ±   2.9     Rectangular    √3        1        ±   1.7   ∞
Max.SAR Eval.               ±   0.0     Rectangular    √3        1        ±   0.0   ∞
Test Sample Related
Deviation of wxp.dipole     ± 0.0       Rectangular    √3        1        ± 0.0     ∞
Dipole Axis to
                            ± 2.0       Rectangular    √3        1        ± 1.2     ∞
Liquid Distance
Input power and
                            ± 3.4       Rectangular    √3        1        ± 2.0     ∞
SAR drift meas.
Phantom and Setup
Phantom uncertainty         ± 4.0       Rectangular    √3        1        ± 2.3     ∞
Algorithm for
correcting SAR
for deviations              ± 1.9       Rectangular    √3        1        ± 1.1     ∞
in permittivity
and conductivity

Liquid conductivity
                            ± 5.0       Normal         1         0.78     + 3.9     ∞
(meas.)

Liquid permittivity
                            ± 5.0       Normal         1         0.26      - 1.3    ∞
(meas.)
Liquid conductivity
- temp.unc                  ± 1.7       Rectangular    √3        0.78     ± 0.8     ∞
(below 2deg.C.)
Liquid permittivity
- temp.unc                  ± 0.3       Rectangular    √3        0.23     ± 0.0     ∞
(below 2deg.C.)

Combined Standard Uncertainty                                             ± 5.945
Expanded Uncertainty (k=2)                                                ± 11.9




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone: +81 596 24 8999
Facsimile: +81 596 24 8124