03 FCC Test Report_DSS

FCC ID: AK8M18DFT1

Test Report

Download: PDF
FCCID_3855343

                                                                                 Test report No.        : 12219846H-A
                                                                                 Page                   : 1 of 34
                                                                                 Issued date            : May 11, 2018
                                                                                 FCC ID                 : AK8M18DFT1



                              RADIO TEST REPORT
                               Test Report No. : 12219846H-A
        Applicant                             :     Sony Interactive Entertainment Inc.

        Type of Equipment                     :     Wireless communication module

        Model No.                             :     J20H096

        FCC ID                                :     AK8M18DFT1

        Test regulation                       :     FCC Part 15 Subpart C: 2018
                                                    For Permissive Change
                                                    *Bluetooth part
                                                    (Maximum Peak Output Power and Radiated Spurious
                                                    Emission tests only)

        Test Result                           :     Complied
           1.   This test report shall not be reproduced in full or partial, without the written approval of UL Japan, Inc.
           2.   The results in this report apply only to the sample tested.
           3.   This sample tested is in compliance with the above regulation.
           4.   The test results in this report are traceable to the national or international standards.
           5.   This test report covers Radio technical requirements. It does not cover administrative issues
                such as Manual or non-Radio test related Requirements. (if applicable)
           6.   The all test items in this test report are conducted by UL Japan, Inc. Ise EMC Lab.
           7.   This test report must not be used by the customer to claim product certification, approval, or
                endorsement by NVLAP, NIST, or any agency of the Federal Government.

                         Date of test:                    January 23 to March 28, 2018

                         Representative test
                         engineer:
                                                               Takumi Shimada
                                                                  Engineer
                                                         Consumer Technology Division


                         Approved by:
                                                              Takayuki Shimada
                                                                   Leader
                                                         Consumer Technology Division
                                                           This laboratory is accredited by the NVLAP LAB CODE
                                                           200572-0, U.S.A. The tests reported herein have been
                                                           performed in accordance with its terms of accreditation.
                                                           *As for the range of Accreditation in NVLAP, you may
                                                           refer to the WEB address,
                                                           http://japan.ul.com/resources/emc_accredited/

       NVLAP LAB CODE: 200572-0

    The testing in which "Non-accreditation" is displayed is outside the accreditation scopes in UL Japan.
    There is no testing item of "Non-accreditation".

UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124                                                                             13-EM-F0429


                                                                    Test report No.   : 12219846H-A
                                                                    Page              : 2 of 34
                                                                    Issued date       : May 11, 2018
                                                                    FCC ID            : AK8M18DFT1




                                  REVISION HISTORY
                               Original Test Report No.: 12219846H-A

Revision     Test report No.         Date             Page      Contents
                                                      revised
-            12219846H-A             May 11, 2018     -         -
(Original)




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                                             Test report No.            : 12219846H-A
                                                                                             Page                       : 3 of 34
                                                                                             Issued date                : May 11, 2018
                                                                                             FCC ID                     : AK8M18DFT1


CONTENTS                                                                                                                             PAGE

SECTION 1: Customer information.......................................................................................................4
SECTION 2: Equipment under test (E.U.T.) .........................................................................................4
SECTION 3: Test specification, procedures & results..........................................................................7
SECTION 4: Operation of E.U.T. during testing ................................................................................10
SECTION 5: Radiated Spurious Emission ..........................................................................................12
SECTION 6: Antenna Terminal Conducted Tests ..............................................................................13
APPENDIX 1: Test data ........................................................................................................................14
    Maximum Peak Output Power .......................................................................................................... 14
    Radiated Spurious Emission ............................................................................................................. 16
APPENDIX 2: Test instruments ...........................................................................................................30
APPENDIX 3: Photographs of test setup .............................................................................................31
    Radiated Spurious Emission ............................................................................................................. 31
    Worst Case Position .......................................................................................................................... 32
    Test Configuration and peripherals ................................................................................................... 34




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                       Test report No.      : 12219846H-A
                                                                       Page                 : 4 of 34
                                                                       Issued date          : May 11, 2018
                                                                       FCC ID               : AK8M18DFT1


SECTION 1:         Customer information
   Company Name                      Sony Interactive Entertainment Inc.
   Brand Name                        SONY
   Address                           1-7-1 Konan, Minato-ku, Tokyo, 108-0075 Japan
   Telephone Number                  +81-50-3807-5639
   Facsimile Number                  +81-50-3807-9594
   Contact Person                    Kiyoto Sasaki



SECTION 2:         Equipment under test (E.U.T.)
2.1       Identification of E.U.T.

   Type of Equipment                 Wireless communication module
   Model No                          J20H096
   Serial No                         Refer to Clause 4.2
   Country of Manufacture            China/Japan
   Receipt Date of Sample            January 20, 2018
   Condition of EUT                  Production prototype
                                     (Not for Sale: This sample is equivalent to mass-produced items.)
   Modification of EUT               No modification by the test lab.


2.2       Product Description

J20H096 is the Wireless communication module.

Product Specification
 Clock frequency in the system (radio part)     26 MHz
 Operating Temperature                          -10 deg. C - +85 deg. C
 Power Supply                                   DC 3.3 V, DC 1.8 V
 Size                                           20 x 18 x 3.0 mm, 55pin LGA




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                        Test report No.    : 12219846H-A
                                                                        Page               : 5 of 34
                                                                        Issued date        : May 11, 2018
                                                                        FCC ID             : AK8M18DFT1



Radio Specification

WLAN (IEEE802.11b/g/n-20)
 Equipment Type                           Transceiver
 Frequency of Operation                   2412 MHz - 2462 MHz
 Type of Modulation                       DSSS, OFDM
 Bandwidth & Channel spacing              Less than 20 MHz & 5 MHz
 Method of frequency generation           Synthesizer
 Antenna Type                             PIFA (Antenna port WA for 2.4 GHz / Antenna port WB)
 Antenna Gain: GANT                       5.6 dBi (Antenna port WA for 2.4 GHz / Antenna port WB)
 Directional Gain *1)                     8.61 dBi

WLAN (IEEE802.11a/11n-20/11ac-20/11n-40/11ac-40/11ac-80)
 Equipment Type                 Transceiver
 Frequency of Operation         U-NII-1: 5180 MHz - 5240 MHz
                                U-NII-2A: 5260 MHz - 5320 MHz
                                U-NII-2C: 5500 MHz - 5700 MHz
                                U-NII-3: 5745 MHz - 5825 MHz
 Type of Modulation             OFDM
 Bandwidth & Channel spacing    Less than 20 MHz / 40 MHz / 80 MHz &
                                20 MHz / 40 MHz / 80 MHz
 Method of frequency generation Synthesizer
 Antenna Type                   PIFA (Antenna port WA for 5 GHz / Antenna port WC for 5 GHz)
 Antenna Gain: GANT             5.0 dBi (Antenna port WA for 5 GHz),
                                5.6 dBi (Antenna port WC for 5 GHz)
 Directional Gain *1)           8.32 dBi

Bluetooth (BDR/EDR)
  Equipment Type                          Transceiver
  Frequency of Operation                  2402 MHz - 2480 MHz
  Type of Modulation                      FHSS (GFSK, π/4DQPSK, 8DPSK)
  Bandwidth & Channel spacing             79 MHz & 1 MHz
  Method of frequency generation          Synthesizer
  Antenna Type                            PIFA (Antenna port WC for 2.4 GHz)
  Antenna Gain                            7.0 dBi (Antenna port WC for 2.4 GHz)

Bluetooth (Low Energy)
   Equipment Type                         Transceiver
   Frequency of Operation                 2402 MHz - 2480 MHz
   Type of Modulation                     GFSK
   Bandwidth & Channel spacing            1 MHz & 2 MHz
   Method of frequency generation         Synthesizer
   Antenna Type                           PIFA (Antenna port WC for 2.4 GHz)
   Antenna Gain                           7.0 dBi (Antenna port WC for 2.4 GHz)

*1) Directional antenna gain =

*This test report applies to Bluetooth.




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                        Test report No.     : 12219846H-A
                                                                        Page                : 6 of 34
                                                                        Issued date         : May 11, 2018
                                                                        FCC ID              : AK8M18DFT1


<Contents of the change from original model>
Test Report Number of original model is 12079942H-A (issued by UL Japan, Inc.)
Antenna was only changed from the original model, and other radio specification is identical to it.
In this report, Radiated Spurious Emission test was performed.
For Maximum Peak Output Power test, test result from the original report and new antenna gain were used in the test
data.
Information of antenna was updated in Section 2.2.




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                                   Test report No.        : 12219846H-A
                                                                                   Page                   : 7 of 34
                                                                                   Issued date            : May 11, 2018
                                                                                   FCC ID                 : AK8M18DFT1


SECTION 3:            Test specification, procedures & results

3.1          Test Specification

Test Specification                      :    FCC Part 15 Subpart C
                                             FCC Part 15 final revised on March 12, 2018 and effective April 11, 2018

Title                                   :
                                      FCC 47CFR Part15 Radio Frequency Device Subpart C Intentional Radiators
                                      Section 15.207 Conducted limits
                                      Section 15.247 Operation within the bands 902-928MHz,
                                      2400-2483.5MHz, and 5725-5850MHz
* The revision on March 12, 2018, does not affect the test specification applied to the EUT.

* Also the EUT complies with FCC Part 15 Subpart B.


3.2          Procedures and results

      Item       Test Procedure                    Specification                     Worst Margin            Results       Remarks
Maximum Peak FCC: FCC Public Notice         FCC: Section15.247(a)(b)(1)
             DA 00-705                                                        See data.                     Complied       Conducted
Output Power
             FCC: FCC Public Notice         FCC: Section15.247(d)
Spurious
             DA 00-705                                                        10.9 dB                                       Radiated
Emission &
             IC: RSS-Gen 6.13               IC: RSS-247 5.5                   3699.978 MHz,                 Complied    (above 30 MHz)
Band Edge
                                            RSS-Gen 8.9                       Horizontal, AV                                  *1)
Compliance
                                            RSS-Gen 8.10
Note: UL Japan, Inc.’s EMI Work Procedures No. 13-EM-W0420 and 13-EM-W0422.
*1) Radiated test was selected over 30 MHz based on section 15.247(d).
Symbols:
Complied                The data of this test item has enough margin, more than the measurement uncertainty.
Complied#               The data of this test item meets the limits unless the measurement uncertainty is taken into consideration.
* In case any questions arise about test procedure, ANSI C63.10: 2013 is also referred.


FCC Part 15.31 (e)
The EUT has the power supply regulator. However one of the input voltages to RF part doesn’t go through the
regulator. The stable voltage will be supplied by the end product, which will be required to have a power supply
regulator. Therefore, the EUT complies with the requirement.

FCC Part 15.203/212 Antenna requirement
The EUT has a unique coupling/antenna connector (U.FL). Therefore the equipment complies with the requirement of
15.203/212.


3.3          Addition to standard

No addition, exclusion nor deviation has been made from the standard.




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                                Test report No.        : 12219846H-A
                                                                                Page                   : 8 of 34
                                                                                Issued date            : May 11, 2018
                                                                                FCC ID                 : AK8M18DFT1


3.4          Uncertainty

The following uncertainties have been calculated to provide a confidence level of 95 % using a coverage factor k=2.

Ise EM C Lab.
Antenna Terminal test
   Test Item                                               Uncertainty (+/-)
RF output power                                                1.3 dB
Antenna terminal conducted emission / Power dencity /
                                                                2.7 dB
Burst power
Adjacent channnel power / Channnel power
                Below 3GHz                                      1.9 dB
                3 GHz ot 6 GHz                                  2.1 dB



Radiated emission
Measurement
                           Frequency range                 Uncertainty (+/-)
   distance
      3m       9 kHz to 30 M Hz                                 3.3 dB
     10 m                                                       3.2 dB

      3m        30 M Hz to 200 M Hz (Horizontal)                4.8 dB
                30 M Hz to 200 M Hz (Vertical)                  5.0 dB
                200 M Hz to 1000 M Hz (Horiozntal)              5.2 dB
                200 M Hz to 1000 M Hz (Vertical)                6.3 dB
      10 m      30 M Hz to 200 M Hz (Horizontal)                4.8 dB
                30 M Hz to 200 M Hz (Vertical)                  4.9 dB
                200 M Hz to 1000 M Hz (Horiozntal)              5.0 dB
                200 M Hz to 1000 M Hz (Vertical)                5.0 dB

      3m        1 GHz to 6 GHz                                  5.0 dB
                6 GHz to 18 GHz                                 5.3 dB
      1m        10 GHz to 26.5 GHz                              5.8 dB
                26.5 GHz to 40 GHz                              5.8 dB
      10 m      1 GHz to 18 GHz                                 5.2 dB




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                                      Test report No.          : 12219846H-A
                                                                                      Page                     : 9 of 34
                                                                                      Issued date              : May 11, 2018
                                                                                      FCC ID                   : AK8M18DFT1


3.5         Test Location

UL Japan, Inc. Ise EM C Lab.
4383-326 Asama-cho, Ise-shi, M ie-ken 516-0021 JAPAN
Telephone: +81 596 24 8999, Facsimile: +81 596 24 8124
NVLAP Lab. code: 200572-0 / FCC Test Firm Registration Number: 199967
                                                                                                                              M aximum
                       IC Registration   Width x Depth x        Size of reference ground plane (m) /
Test site                                                                                               Other rooms           measurement
                       Number            Height (m)             horizontal conducting plane
                                                                                                                              distance
No.1 semi-anechoic                                                                                        No.1 Power source
                         2973C-1           19.2 x 11.2 x 7.7     7.0 x 6.0                                                    10 m
chamber                                                                                                   room
No.2 semi-anechoic
                         2973C-2           7.5 x 5.8 x 5.2       4.0 x 4.0                                -                   3m
chamber
No.3 semi-anechoic                                                                                        No.3 Preparation
                         2973C-3           12.0 x 8.5 x 5.9      6.8 x 5.75                                                   3m
chamber                                                                                                   room
No.3 shielded room       -                 4.0 x 6.0 x 2.7       N/A                                      -                   -
No.4 semi-anechoic                                                                                        No.4 Preparation
                         2973C-4           12.0 x 8.5 x 5.9      6.8 x 5.75                                                   3m
chamber                                                                                                   room
No.4 shielded room       -                 4.0 x 6.0 x 2.7       N/A                                      -                   -
No.5 semi-anechoic
                         -                 6.0 x 6.0 x 3.9       6.0 x 6.0                                -                   -
chamber
No.6 shielded room       -                 4.0 x 4.5 x 2.7       4.0 x 4.5                                -                   -
No.6 measurement
                         -                 4.75 x 5.4 x 3.0      4.75 x 4.15                              -                   -
room
No.7 shielded room       -                 4.7 x 7.5 x 2.7       4.7 x 7.5                                -                   -
No.8 measurement
                         -                 3.1 x 5.0 x 2.7       N/A                                      -                   -
room
No.9 measurement
                         -                 8.8 x 4.6 x 2.8       2.4 x 2.4                                -                   -
room
No.11 measurement
                         -                 6.2 x 4.7 x 3.0       4.8 x 4.6                                -                   -
room
* Size of vertical conducting plane (for Conducted Emission test) : 2.0 m x 2.0 m for No.1, No.2, No.3, and No.4 semi-
anechoic chambers and No.3 and No.4 shielded rooms.




3.6         Test data, Test instruments, and Test set up

Refer to APPENDIX.




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                            Test report No.      : 12219846H-A
                                                                            Page                 : 10 of 34
                                                                            Issued date          : May 11, 2018
                                                                            FCC ID               : AK8M18DFT1


SECTION 4:          Operation of E.U.T. during testing

4.1       Operating Mode(s)

        Bluetooth (BT):    Transmitting (Tx), Payload: PRBS9

      Details of Operating Mode(s)
Test Item                                          Mode                                                Tested frequency
Radiated Spurious Emission                         Tx (Hopping Off) DH5, 3DH5                          2402 MHz
                                                                                                       2441 MHz
                                                                                                       2480 MHz
Maximum Peak Output Power                          Tx (Hopping Off) DH5, 2DH5, 3DH5                    2402 MHz
                                                                                                       2441 MHz
                                                                                                       2480 MHz
*As a result of preliminary test, the formal test was performed with the above modes, which had the
maximum payload length (except Dwell time test)
*2DH mode (2Mb/s EDR: pi/4DQPSK) was excluded for other tests than power measurement by using 3DH mode (3
Mb/s EDR: 8DPSK) as a representative.
* It is considered that the non-tested packet type (e.g. inquiry) can be omitted as it is complied with above all the test
items based on Bluetooth Core specification.

*EUT has the power settings by the software as follows;
Power settings:       Same as production model
Software:            MT_TEST_Tool_Ver6.3
*This setting of software is the worst case.
Any conditions under the normal use do not exceed the condition of setting.
In addition, end users cannot change the settings of the output power of the product.

      Simultaneously transmission
      Test Item                        Mode *1)
      Radiated Spurious Emission       Tx (Hopping Off) 3DH5 2402 MHz + 11ac-40 5550 MHz
                                       Tx (Hopping Off) 3DH5 2441 MHz + 11ac-40 5550 MHz
                                       Tx (Hopping Off) 3DH5 2480 MHz + 11ac-40 5550 MHz
      *1) The test was performed on the mode as a representative, because it had the highest power of 5 GHz
      band at antenna terminal test.




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                             Test report No.    : 12219846H-A
                                                             Page               : 11 of 34
                                                             Issued date        : May 11, 2018
                                                             FCC ID             : AK8M18DFT1


4.2       Configuration and peripherals




                         This page has been submitted for a separate exhibit.




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                         Test report No.      : 12219846H-A
                                                                         Page                 : 12 of 34
                                                                         Issued date          : May 11, 2018
                                                                         FCC ID               : AK8M18DFT1


SECTION 5: Radiated Spurious Emission
Test Procedure

[For below 1 GHz]
EUT was placed on a urethane platform of nominal size, 0.5 m by 1.0 m, raised 0.8 m above the conducting ground
plane. The Radiated Electric Field Strength has been measured in a Semi Anechoic Chamber with a ground plane.

[For above 1 GHz]
EUT was placed on a urethane platform of nominal size, 0.5 m by 0.5 m, raised 1.5 m above the conducting ground
plane.
The Radiated Electric Field Strength has been measured in a Semi Anechoic Chamber with absorbent materials lined
on a ground plane.

The height of the measuring antenna varied between 1 and 4 m and EUT was rotated a full revolution in order to
obtain the maximum value of the electric field strength.
The measurements were performed for both vertical and horizontal antenna polarization with the Test Receiver, or the
Spectrum Analyzer.
The measurements were made with the following detector function of the test receiver and the Spectrum analyzer (in
linear mode).
The test was made with the detector (RBW/VBW) in the following table.
When using Spectrum analyzer, the test was made with adjusting span to zero by using peak hold.

Test Antennas are used as below;
   Frequency          30 MHz to 200 MHz         200 MHz to 1 GHz        Above 1 GHz
   Antenna Type       Biconical                 Logperiodic             Horn

In any 100 kHz bandwidth outside the restricted band in which the spread spectrum intentional radiator is operating,
the radio frequency power that is produced by the intentional radiator confirmed 20 dB below that in the 100 kHz
bandwidth within the band that contains the highest level of the desired power, based on a radiated measurement.

20 dBc was applied to the frequency over the limit of FCC 15.209 / Table 4 of RSS-Gen 8.9 (IC) and outside the
restricted band of FCC15.205 / Table 6 of RSS-Gen 8.10 (IC).
   Frequency            Below 1 GHz        Above 1 GHz                        20 dBc
   Instrument used      Test Receiver      Spectrum Analyzer                  Spectrum Analyzer
   Detector             QP                 PK                 AV              PK
   IF Bandwidth         BW 120 kHz         RBW: 1 MHz         RBW: 1 MHz      RBW: 100 kHz
                                           VBW: 3 MHz         VBW: 10 Hz *1)  VBW: 300 kHz
   Test Distance        3m                 4.5 m *2) (1 GHz - 10 GHz),        4.5 m *2) (1 GHz - 10 GHz),
                                           1 m *3) (10 GHz - 26.5 GHz)        1 m *3) (10 GHz - 26.5 GHz)
*1) Although DA 00-705 accepts VBW = 10 Hz for AV measurements, it was confirmed that superfluous smoothing was
not performed.
*2) Distance Factor: 20 x log (4.5 m / 3.0 m) = 3.53 dB
*3) Distance Factor: 20 x log (1.0 m / 3.0 m) = -9.5 dB

- The carrier level and noise levels were confirmed at each position of X, Y and Z axes of EUT (Antenna and Module) to
see the position of maximum noise, and the test was made at the position that has the maximum noise.

The test results and limit are rounded off to one decimal place, so some differences might be observed.

Measurement range              : 30 MHz - 26.5 GHz
Test data                      : APPENDIX
Test result                    : Pass




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                         Test report No.      : 12219846H-A
                                                                         Page                 : 13 of 34
                                                                         Issued date          : May 11, 2018
                                                                         FCC ID               : AK8M18DFT1


SECTION 6:             Antenna Terminal Conducted Tests
Test Procedure

The tests were made with below setting connected to the antenna port.

Test               Span                  RBW       VBW         Sweep time          Detector   Trace        Instrument used
Maximum Peak       -                     -         -           Auto                Peak       -            Power Meter
Output Power                                                                                               (Sensor: 50MHz BW)

The test results and limit are rounded off to two decimals place, so some differences might be observed.

Test data                      : APPENDIX
Test result                    : Pass




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                                             Test report No.            : 12219846H-A
                                                                                             Page                       : 14 of 34
                                                                                             Issued date                : May 11, 2018
                                                                                             FCC ID                     : AK8M18DFT1


APPENDIX 1: Test data

                                                  Maximum Peak Output Power
                         Report No.                          12219846H
                         Test place                          Ise EMC Lab. No.11 Measurement Room
                         Date                                January 23, 2018
                         Temperature / Humidity              23 deg. C / 20 % RH
                         Engineer                            Yuta Moriya
                         Mode                                Tx, Hopping Off

                Mode         Freq.      Reading      Cable       Atten.            Result                    Limit           Margin
                                                     Loss        Loss
                            [MHz]       [dBm]        [dB]        [dB]        [dBm]          [mW]     [dBm]           [mW]     [dB]
                DH5         2402.0      -7.49        0.50        9.71         2.72           1.87    19.96           99.08   17.24
                DH5         2441.0      -8.11        0.50        9.71         2.10           1.62    19.96           99.08   17.86
                DH5         2480.0      -7.78        0.50        9.71         2.43           1.75    19.96           99.08   17.53
                2DH5        2402.0      -4.73        0.50        9.71         5.48           3.53    19.96           99.08   14.48
                2DH5        2441.0      -5.53        0.50        9.71         4.68           2.94    19.96           99.08   15.28
                2DH5        2480.0      -5.23        0.50        9.71         4.98           3.15    19.96           99.08   14.98
                3DH5        2402.0      -4.36        0.50        9.71         5.85           3.85    19.96           99.08   14.11
                3DH5        2441.0      -5.13        0.50        9.71         5.08           3.22    19.96           99.08   14.88
                3DH5        2480.0      -4.80        0.50        9.71         5.41           3.48    19.96           99.08   14.55

              Sample Calculation:
              Result = Reading + Cable Loss (including the cable(s) customer supplied) + Attenuator Loss
              *This Limit was reduced by the amount in dB (1.0 dB)
              that the directional gain of the antenna exceeding 6 dBi.
              *The equipment and cables were not used for factor 0 dB of the data sheets.


Test was not performed at AFH mode, because the decrease of number of channel (min: 20ch) at AFH mode does not influence on the output power
and bandwidth of the EUT.
As this device had AFH mode and frequency separation could not meet the requirement of over 20dB BW without 2/3 relaxation, 125mW power
limit was applied to it.




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                             Test report No.         : 12219846H-A
                                                                             Page                    : 15 of 34
                                                                             Issued date             : May 11, 2018
                                                                             FCC ID                  : AK8M18DFT1


                                                Burst Rate Confirmation
                       Report No.                  12219846H
                       Test place                  Ise EMC Lab. No.11 Measurement Room
                       Date                        January 23, 2018
                       Temperature / Humidity      23 deg. C / 20 % RH
                       Engineer                    Yuta Moriya
                       Mode                        Tx, Hopping Off

                               DH5
    Tx on / (Tx on + Tx off) =                    0.769
    Tx on / (Tx on + Tx off) * 100 =               76.9 %
    Duty factor = 10 * log (3.75 / 2.885) =        1.14 dB




                              2DH5                                                        3DH5
    Tx on / (Tx on + Tx off) =                    0.770         Tx on / (Tx on + Tx off) =                     0.770
    Tx on / (Tx on + Tx off) * 100 =               77.0 %       Tx on / (Tx on + Tx off) * 100 =                77.0 %
    Duty factor = 10 * log (3.75 / 2.888) =        1.13 dB      Duty factor = 10 * log (3.75 / 2.889) =         1.13 dB




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                                                          Test report No.                     : 12219846H-A
                                                                                                          Page                                : 16 of 34
                                                                                                          Issued date                         : May 11, 2018
                                                                                                          FCC ID                              : AK8M18DFT1




                                                         Radiated Spurious Emission

 Report No.                           12219846H
 Test place                           Ise EMC Lab.
 Semi Anechoic Chamber                No.3                  No.3                                           No.3                                 No.3
 Date                                 March 18, 2018        March 22, 2018                                 March 25, 2018                       March 27, 2018
 Temperature / Humidity               23 deg. C / 36 % RH   20 deg. C / 38 % RH                            22 deg. C / 31 % RH                  25 deg. C / 33 % RH
 Engineer                             Tomoki Matsui         Takumi Shimada                                 Takafumi Noguchi                     Masafumi Niwa
                                      (1 GHz - 10 GHz)      (10 GHz - 18 GHz)                              (18 GHz - 26.5 GHz)                  (Below 1 GHz)
 Mode                                 Tx, Hopping Off, DH5 2402 MHz

            Polarity Frequency Detector Reading Ant.Fac. Loss                Gain Duty Factor Result            Limit  Margin                 Remark
            消すな         [MHz]                [dBuV] [dB/m]          [dB]      [dB]      [dB]     [dBuV/m] [dBuV/m] [dB]
           Hori           45.300 QP             22.2       12.2        7.4      32.2           -        9.6       40.0   30.4
           Hori          129.000 QP             24.0       13.5        8.5      32.2           -       13.8       43.5   29.7
           Hori          244.000 QP             21.5       11.5        9.6      32.0           -       10.6       46.0   35.4
           Hori          501.400 QP             21.4       17.5       11.3      32.0           -       18.2       46.0   27.8
           Hori          833.663 QP             21.2       21.1       13.2      31.3           -       24.2       46.0   21.8
           Hori          968.370 QP             20.1       22.2       13.8      30.6           -       25.5       53.9   28.4
           Hori         2390.000 PK             41.0       27.7        6.7      32.7           -       42.7       73.9   31.2
           Hori         3603.076 PK             45.5       29.5        9.0      32.2           -       51.8       73.9   22.1
           Hori         4804.000 PK             41.4       31.6        9.0      31.8           -       50.2       73.9   23.7   Floor noise
           Hori         7206.000 PK             42.5       36.0       10.4      32.6           -       56.3       73.9   17.6   Floor noise
           Hori         9608.000 PK             42.2       38.5       10.9      33.3           -       58.3       73.9   15.6   Floor noise
           Hori         2390.000 AV             29.6       27.7        6.7      32.7           -       31.3       53.9   22.6
           Hori         3603.076 AV             35.8       29.5        9.0      32.2           -       42.1       53.9   11.8
           Hori         4804.000 AV             28.6       31.6        9.0      31.8           -       37.4       53.9   16.5   Floor noise
           Hori         7206.000 AV             30.2       36.0       10.4      32.6           -       44.0       53.9    9.9   Floor noise
           Hori         9608.000 AV             30.3       38.5       10.9      33.3           -       46.4       53.9    7.5   Floor noise
           Vert           45.300 QP             22.3       12.2        7.4      32.2           -        9.7       40.0   30.3
           Vert          129.000 QP             23.2       13.5        8.5      32.2           -       13.0       43.5   30.5
           Vert          244.000 QP             21.3       11.5        9.6      32.0           -       10.4       46.0   35.6
           Vert          501.400 QP             21.3       17.5       11.3      32.0           -       18.1       46.0   27.9
           Vert          833.663 QP             21.2       21.1       13.2      31.3           -       24.2       46.0   21.8
           Vert          968.370 QP             20.2       22.2       13.8      30.6           -       25.6       53.9   28.3
           Vert         2390.000 PK             42.8       27.7        6.7      32.7           -       44.5       73.9   29.4
           Vert         3603.076 PK             43.3       29.5        9.0      32.2           -       49.6       73.9   24.3
           Vert         4804.000 PK             41.2       31.6        9.0      31.8           -       50.0       73.9   23.9   Floor noise
           Vert         7206.000 PK             43.2       36.0       10.4      32.6           -       57.0       73.9   16.9   Floor noise
           Vert         9608.000 PK             42.4       38.5       10.9      33.3           -       58.5       73.9   15.4   Floor noise
           Vert         2390.000 AV             29.7       27.7        6.7      32.7           -       31.4       53.9   22.5
           Vert         3603.076 AV             33.5       29.5        9.0      32.2           -       39.8       53.9   14.1
           Vert         4804.000 AV             28.7       31.6        9.0      31.8           -       37.5       53.9   16.4   Floor noise
           Vert         7206.000 AV             30.2       36.0       10.4      32.6           -       44.0       53.9    9.9   Floor noise
           Vert         9608.000 AV             30.3       38.5       10.9      33.3           -       46.4       53.9    7.5   Floor noise
           Result = Reading + Ant Factor + Loss (Cable+Attenuator+Filter+Distance factor(above 1 GHz)) - Gain(Amplifier)
           *Other frequency noises omitted in this report were not seen or had enough margin (more than 20 dB).
           消すな
           Distance factor:      1 GHz - 10 GHz        20log (4.5 m / 3.0 m) = 3.53 dB
           消すな                   10 GHz - 26.5 GHz 20log (1.0 m / 3.0 m) = -9.5 dB



        20dBc Data Sheet
        Polarity  Frequency Detector Reading        Ant      Loss      Gain     Result    Limit    Margin      Remark
                                                   Factor
                     [MHz]               [dBuV] [dB/m]       [dB]      [dB] [dBuV/m][dBuV/m] [dB]
        Hori        2402.000 PK             90.6     27.7       6.8      32.7      92.4          -        - Carrier
        Hori        2400.000 PK             35.7     27.7       6.8      32.7      37.5      72.4     34.9
        Vert        2402.000 PK             91.8     27.7       6.8      32.7      93.6          -        - Carrier
        Vert        2400.000 PK             36.0     27.7       6.8      32.7      37.8      73.6     35.8
        Result = Reading + Ant Factor + Loss (Cable+Attenuator+Filter+Distance factor(above 1 GHz)) - Gain(Amprifier)

                                  *These results have sufficient margin without taking account Dwell time factor.




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                        Test report No.       : 12219846H-A
                                                                        Page                  : 17 of 34
                                                                        Issued date           : May 11, 2018
                                                                        FCC ID                : AK8M18DFT1


                                        Radiated Spurious Emission
                                       (Reference Plot for band-edge)

 Report No.                 12219846H
 Test place                 Ise EMC Lab.
 Semi Anechoic Chamber      No.3                  No.3                  No.3                    No.3
 Date                       March 18, 2018        March 22, 2018        March 25, 2018          March 27, 2018
 Temperature / Humidity     23 deg. C / 36 % RH   20 deg. C / 38 % RH   22 deg. C / 31 % RH     25 deg. C / 33 % RH
 Engineer                   Tomoki Matsui         Takumi Shimada        Takafumi Noguchi        Masafumi Niwa
                            (1 GHz - 10 GHz)      (10 GHz - 18 GHz)     (18 GHz - 26.5 GHz)     (Below 1 GHz)
 Mode                       Tx, Hopping Off, DH5 2402 MHz



                                                      Horizontal
           Restricted-band band-edge Plot                          Authorized-band band-edge Plot




               Trace Green : Peak Plot                                           20dBc Plot
             Trace Purple : Average Plot

                                                       Vertical
           Restricted-band band-edge Plot                          Authorized-band band-edge Plot




              Trace Green : Peak Plot                                            20dBc Plot
            Trace Purple : Average Plot
* Final result of restricted band edge was shown in tabular data.




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                                                         Test report No.                     : 12219846H-A
                                                                                                         Page                                : 18 of 34
                                                                                                         Issued date                         : May 11, 2018
                                                                                                         FCC ID                              : AK8M18DFT1


                                                        Radiated Spurious Emission

 Report No.                          12219846H
 Test place                          Ise EMC Lab.
 Semi Anechoic Chamber               No.3                  No.3                                           No.3                                 No.3
 Date                                March 18, 2018        March 22, 2018                                 March 25, 2018                       March 27, 2018
 Temperature / Humidity              23 deg. C / 36 % RH   20 deg. C / 38 % RH                            22 deg. C / 31 % RH                  25 deg. C / 33 % RH
 Engineer                            Tomoki Matsui         Takumi Shimada                                 Takafumi Noguchi                     Masafumi Niwa
                                     (1 GHz - 10 GHz)      (10 GHz - 18 GHz)                              (18 GHz - 26.5 GHz)                  (Below 1 GHz)
 Mode                                Tx, Hopping Off, DH5 2441 MHz

           Polarity Frequency Detector Reading Ant.Fac. Loss                Gain Duty Factor       Result      Limit  Margin                 Remark
           消すな         [MHz]                [dBuV] [dB/m]          [dB]      [dB]      [dB]     [dBuV/m] [dBuV/m] [dB]
          Hori           45.300 QP             22.3       12.2        7.4      32.2           -        9.7       40.0   30.3
          Hori          129.000 QP             23.8       13.5        8.5      32.2           -       13.6       43.5   29.9
          Hori          244.000 QP             21.4       11.5        9.6      32.0           -       10.5       46.0   35.5
          Hori          501.400 QP             21.5       17.5       11.3      32.0           -       18.3       46.0   27.7
          Hori          833.663 QP             21.1       21.1       13.2      31.3           -       24.1       46.0   21.9
          Hori          968.370 QP             20.2       22.2       13.8      30.6           -       25.6       53.9   28.3
          Hori         3661.566 PK             42.7       29.6        8.9      32.2           -       49.0       73.9   24.9
          Hori         4882.000 PK             40.8       31.9        9.0      31.7           -       50.0       73.9   23.9   Floor noise
          Hori         7323.000 PK             42.0       36.2       10.4      32.7           -       55.9       73.9   18.0   Floor noise
          Hori         9764.000 PK             42.0       38.7       11.0      33.4           -       58.3       73.9   15.6   Floor noise
          Hori         3661.566 AV             31.4       29.6        8.9      32.2           -       37.7       53.9   16.2
          Hori         4882.000 AV             28.3       31.9        9.0      31.7           -       37.5       53.9   16.4   Floor noise
          Hori         7323.000 AV             30.0       36.2       10.4      32.7           -       43.9       53.9   10.0   Floor noise
          Hori         9764.000 AV             29.9       38.7       11.0      33.4           -       46.2       53.9    7.7   Floor noise
          Vert           45.300 QP             22.3       12.2        7.4      32.2           -        9.7       40.0   30.3
          Vert          129.000 QP             23.2       13.5        8.5      32.2           -       13.0       43.5   30.5
          Vert          244.000 QP             21.4       11.5        9.6      32.0           -       10.5       46.0   35.5
          Vert          501.400 QP             21.3       17.5       11.3      32.0           -       18.1       46.0   27.9
          Vert          833.663 QP             21.1       21.1       13.2      31.3           -       24.1       46.0   21.9
          Vert          968.370 QP             20.3       22.2       13.8      30.6           -       25.7       53.9   28.2
          Vert         3661.566 PK             43.8       29.6        8.9      32.2           -       50.1       73.9   23.8
          Vert         4882.000 PK             41.3       31.9        9.0      31.7           -       50.5       73.9   23.4   Floor noise
          Vert         7323.000 PK             43.0       36.2       10.4      32.7           -       56.9       73.9   17.0   Floor noise
          Vert         9764.000 PK             42.3       38.7       11.0      33.4           -       58.6       73.9   15.3   Floor noise
          Vert         3661.566 AV             31.1       29.6        8.9      32.2           -       37.4       53.9   16.5
          Vert         4882.000 AV             28.6       31.9        9.0      31.7           -       37.8       53.9   16.1   Floor noise
          Vert         7323.000 AV             30.0       36.2       10.4      32.7           -       43.9       53.9   10.0   Floor noise
          Vert         9764.000 AV             30.1       38.7       11.0      33.4           -       46.4       53.9    7.5   Floor noise
          Result = Reading + Ant Factor + Loss (Cable+Attenuator+Filter+Distance factor(above 1 GHz)) - Gain(Amplifier)
          *Other frequency noises omitted in this report were not seen or had enough margin (more than 20 dB).
          消すな
          Distance factor:      1 GHz - 10 GHz        20log (4.5 m / 3.0 m) = 3.53 dB
          消すな                   10 GHz - 26.5 GHz 20log (1.0 m / 3.0 m) = -9.5 dB

                                 *These results have sufficient margin without taking account Dwell time factor.




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                                                         Test report No.                     : 12219846H-A
                                                                                                         Page                                : 19 of 34
                                                                                                         Issued date                         : May 11, 2018
                                                                                                         FCC ID                              : AK8M18DFT1


                                                        Radiated Spurious Emission

 Report No.                          12219846H
 Test place                          Ise EMC Lab.
 Semi Anechoic Chamber               No.3                  No.3                                           No.3                                 No.3
 Date                                March 18, 2018        March 22, 2018                                 March 25, 2018                       March 27, 2018
 Temperature / Humidity              23 deg. C / 36 % RH   20 deg. C / 38 % RH                            22 deg. C / 31 % RH                  25 deg. C / 33 % RH
 Engineer                            Tomoki Matsui         Takumi Shimada                                 Takafumi Noguchi                     Masafumi Niwa
                                     (1 GHz - 10 GHz)      (10 GHz - 18 GHz)                              (18 GHz - 26.5 GHz)                  (Below 1 GHz)
 Mode                                Tx, Hopping Off, DH5 2480 MHz

           Polarity Frequency Detector Reading Ant.Fac. Loss                Gain Duty Factor       Result      Limit  Margin                 Remark
           消すな         [MHz]                [dBuV] [dB/m]          [dB]      [dB]      [dB]     [dBuV/m] [dBuV/m] [dB]
          Hori           45.300 QP             22.3       12.2        7.4      32.2           -        9.7       40.0   30.3
          Hori          129.000 QP             23.8       13.5        8.5      32.2           -       13.6       43.5   29.9
          Hori          244.000 QP             21.5       11.5        9.6      32.0           -       10.6       46.0   35.4
          Hori          501.400 QP             21.3       17.5       11.3      32.0           -       18.1       46.0   27.9
          Hori          833.663 QP             21.1       21.1       13.2      31.3           -       24.1       46.0   21.9
          Hori          968.370 QP             20.2       22.2       13.8      30.6           -       25.6       53.9   28.3
          Hori         2483.500 PK             42.6       27.8        6.8      32.7           -       44.5       73.9   29.4
          Hori         3719.948 PK             41.7       29.6        9.0      32.2           -       48.1       73.9   25.8
          Hori         4960.000 PK             41.0       32.1        9.1      31.7           -       50.5       73.9   23.4   Floor noise
          Hori         7440.000 PK             41.8       36.4       10.3      32.7           -       55.8       73.9   18.1   Floor noise
          Hori         9920.000 PK             42.1       38.9       11.0      33.4           -       58.6       73.9   15.3   Floor noise
          Hori         2483.500 AV             30.5       27.8        6.8      32.7           -       32.4       53.9   21.5
          Hori         3719.948 AV             30.2       29.6        9.0      32.2           -       36.6       53.9   17.3
          Hori         4960.000 AV             28.5       32.1        9.1      31.7           -       38.0       53.9   15.9   Floor noise
          Hori         7440.000 AV             30.0       36.4       10.3      32.7           -       44.0       53.9    9.9   Floor noise
          Hori         9920.000 AV             29.9       38.9       11.0      33.4           -       46.4       53.9    7.5   Floor noise
          Vert           45.300 QP             22.3       12.2        7.4      32.2           -        9.7       40.0   30.3
          Vert          129.000 QP             23.4       13.5        8.5      32.2           -       13.2       43.5   30.3
          Vert          244.000 QP             21.4       11.5        9.6      32.0           -       10.5       46.0   35.5
          Vert          501.400 QP             21.3       17.5       11.3      32.0           -       18.1       46.0   27.9
          Vert          833.663 QP             21.2       21.1       13.2      31.3           -       24.2       46.0   21.8
          Vert          968.370 QP             20.1       22.2       13.8      30.6           -       25.5       53.9   28.4
          Vert         2483.500 PK             43.1       27.8        6.8      32.7           -       45.0       73.9   28.9
          Vert         3719.948 PK             41.7       29.6        9.0      32.2           -       48.1       73.9   25.8
          Vert         4960.000 PK             41.4       32.1        9.1      31.7           -       50.9       73.9   23.0   Floor noise
          Vert         7440.000 PK             43.1       36.4       10.3      32.7           -       57.1       73.9   16.8   Floor noise
          Vert         9920.000 PK             42.1       38.9       11.0      33.4           -       58.6       73.9   15.3   Floor noise
          Vert         2483.500 AV             30.3       27.8        6.8      32.7           -       32.2       53.9   21.7
          Vert         3719.948 AV             30.2       29.6        9.0      32.2           -       36.6       53.9   17.3
          Vert         4960.000 AV             28.7       32.1        9.1      31.7           -       38.2       53.9   15.7   Floor noise
          Vert         7440.000 AV             29.9       36.4       10.3      32.7           -       43.9       53.9   10.0   Floor noise
          Vert         9920.000 AV             30.2       38.9       11.0      33.4           -       46.7       53.9    7.2   Floor noise
          Result = Reading + Ant Factor + Loss (Cable+Attenuator+Filter+Distance factor(above 1 GHz)) - Gain(Amplifier)
          *Other frequency noises omitted in this report were not seen or had enough margin (more than 20 dB).
          消すな
          Distance factor:      1 GHz - 10 GHz        20log (4.5 m / 3.0 m) = 3.53 dB
          消すな                   10 GHz - 26.5 GHz 20log (1.0 m / 3.0 m) = -9.5 dB

                                 *These results have sufficient margin without taking account Dwell time factor.




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                       Test report No.   : 12219846H-A
                                                                       Page              : 20 of 34
                                                                       Issued date       : May 11, 2018
                                                                       FCC ID            : AK8M18DFT1


                                        Radiated Spurious Emission
                                       (Reference Plot for band-edge)

            Report No.                 12219846H
            Test place                 Ise EMC Lab.
            Semi Anechoic Chamber      No.3
            Date                       March 18, 2018
            Temperature / Humidity     23 deg. C / 36 % RH
            Engineer                   Tomoki Matsui
                                       (1 GHz - 10 GHz)
            Mode                       Tx, Hopping Off, DH5 2480 MHz



                                                 Horizontal
                                       Restricted-band band-edge Plot




                                           Trace Green : Peak Plot
                                         Trace Purple : Average Plot

                                                   Vertical
                                       Restricted-band band-edge Plot




                                       Trace Green : Peak Plot
                                     Trace Purple : Average Plot
* Final result of restricted band edge was shown in tabular data.




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                                                                      Test report No.             : 12219846H-A
                                                                                                                      Page                        : 21 of 34
                                                                                                                      Issued date                 : May 11, 2018
                                                                                                                      FCC ID                      : AK8M18DFT1


                                                               Radiated Spurious Emission

 Report No.                                 12219846H
 Test place                                 Ise EMC Lab.
 Semi Anechoic Chamber                      No.3                  No.3                                                No.3                              No.3
 Date                                       March 18, 2018        March 22, 2018                                      March 25, 2018                    March 27, 2018
 Temperature / Humidity                     23 deg. C / 36 % RH   20 deg. C / 38 % RH                                 22 deg. C / 31 % RH               25 deg. C / 33 % RH
 Engineer                                   Tomoki Matsui         Takumi Shimada                                      Takafumi Noguchi                  Masafumi Niwa
                                            (1 GHz - 10 GHz)      (10 GHz - 18 GHz)                                   (18 GHz - 26.5 GHz)               (Below 1 GHz)
 Mode                                       Tx, Hopping Off, 3DH5 2402 MHz

       Polarity      Frequency   Detector    Reading   Ant.Fac.     Loss       Gain      Duty Factor         Result      Limit    M argin                Remark
       消すな            [M Hz]                 [dBuV]    [dB/m]       [dB]       [dB]         [dB]           [dBuV/m]    [dBuV/m]    [dB]
      Hori                45.300 QP             22.2       12.2         7.4      32.2                  -        9.6        40.0      30.4
      Hori               129.000 QP             24.0       13.5         8.5      32.2                  -       13.8        43.5      29.7
      Hori               244.000 QP             21.4       11.5        9.6       32.0                  -       10.5        46.0      35.5
      Hori               501.400 QP             21.4       17.5       11.3       32.0                  -       18.2        46.0      27.8
      Hori               833.663 QP             21.3       21.1       13.2       31.3                  -       24.3        46.0      21.7
      Hori               968.370 QP             20.2       22.2       13.8       30.6                  -       25.6        53.9      28.3
      Hori            2390.000 PK               42.1       27.7         6.7      32.7                  -       43.8        73.9      30.1
      Hori            3603.078 PK               44.6       29.5         9.0      32.2                  -       50.9        73.9      23.0
      Hori            4804.000 PK               42.0       31.6        9.0       31.8                  -       50.8        73.9      23.1 Floor noise
      Hori            7206.000 PK               43.0       36.0       10.4       32.6                  -       56.8        73.9      17.1 Floor noise
      Hori            9608.000 PK               42.5       38.5       10.9       33.3                  -       58.6        73.9      15.3 Floor noise
      Hori            2390.000 AV               29.7       27.7        6.7       32.7                  -       31.4        53.9      22.5
      Hori            3603.078 AV               33.2       29.5        9.0       32.2                  -       39.5        53.9      14.4
      Hori            4804.000 AV               28.6       31.6        9.0       31.8                  -       37.4        53.9      16.5 Floor noise
      Hori            7206.000 AV               30.2       36.0       10.4       32.6                  -       44.0        53.9       9.9 Floor noise
      Hori            9608.000 AV               30.4       38.5       10.9       33.3                  -       46.5        53.9       7.4 Floor noise
      Vert              45.300 QP               22.2       12.2        7.4       32.2                  -        9.6        40.0      30.4
      Vert               129.000 QP             23.3       13.5         8.5      32.2                  -       13.1        43.5      30.4
      Vert               244.000 QP             21.3       11.5         9.6      32.0                  -       10.4        46.0      35.6
      Vert               501.400 QP             21.4       17.5       11.3       32.0                  -       18.2        46.0      27.8
      Vert               833.663 QP             21.1       21.1       13.2       31.3                  -       24.1        46.0      21.9
      Vert             968.370 QP               20.3       22.2       13.8       30.6                  -       25.7        53.9      28.2
      Vert            2390.000 PK               42.2       27.7        6.7       32.7                  -       43.9        73.9      30.0
      Vert            3603.078 PK               42.4       29.5        9.0       32.2                  -       48.7        73.9      25.2
      Vert            4804.000 PK               40.9       31.6        9.0       31.8                  -       49.7        73.9      24.2 Floor noise
      Vert            7206.000 PK               43.1       36.0       10.4       32.6                  -       56.9        73.9      17.0 Floor noise
      Vert            9608.000 PK               42.6       38.5       10.9       33.3                  -       58.7        73.9      15.2 Floor noise
      Vert            2390.000 AV               29.6       27.7        6.7       32.7                  -       31.3        53.9      22.6
      Vert            3603.078 AV               30.9       29.5         9.0      32.2                  -       37.2        53.9      16.7
      Vert            4804.000 AV               28.6       31.6         9.0      31.8                  -       37.4        53.9      16.5 Floor noise
      Vert            7206.000 AV               30.2       36.0       10.4       32.6                  -       44.0        53.9       9.9 Floor noise
      Vert            9608.000 AV               30.4       38.5       10.9       33.3                  -       46.5        53.9       7.4 Floor noise
      Result = Reading + Ant Factor + Loss (Cable+Attenuator+Filter+Distance factor(above 1 GHz)) - Gain(Amplifier)
      *Other frequency noises omitted in this report were not seen or had enough margin (more than 20 dB).
      消すな
      Distance factor:           1 GHz - 10 GHz        20log (4.5 m / 3.0 m) = 3.53 dB
      消すな                        10 GHz - 26.5 GHz 20log (1.0 m / 3.0 m) = -9.5 dB




                  20dBc Data Sheet
                  Polarity  Frequency Detector Reading        Ant      Loss      Gain     Result    Limit Margin         Remark
                                                             Factor
                               [MHz]               [dBuV] [dB/m]       [dB]      [dB] [dBuV/m][dBuV/m] [dB]
                  Hori        2402.000 PK             93.1     27.7       6.8      32.7      94.9         -         - Carrier
                  Hori        2400.000 PK             37.3     27.7       6.8      32.7      39.1     74.9      35.8
                  Vert        2402.000 PK             91.4     27.7       6.8      32.7      93.2         -         - Carrier
                  Vert        2400.000 PK             36.4     27.7       6.8      32.7      38.2     73.2      35.0
                  Result = Reading + Ant Factor + Loss (Cable+Attenuator+Filter+Distance factor(above 1 GHz)) - Gain(Amprifier)


                                      *These results have sufficient margin without taking account Dwell time factor.




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                        Test report No.   : 12219846H-A
                                                                        Page              : 22 of 34
                                                                        Issued date       : May 11, 2018
                                                                        FCC ID            : AK8M18DFT1


                                        Radiated Spurious Emission
                                       (Reference Plot for band-edge)

            Report No.                 12219846H
            Test place                 Ise EMC Lab.
            Semi Anechoic Chamber      No.3
            Date                       March 18, 2018
            Temperature / Humidity     23 deg. C / 36 % RH
            Engineer                   Tomoki Matsui
                                       (1 GHz - 10 GHz)
            Mode                       Tx, Hopping Off, 3DH5 2402 MHz



                                                      Horizontal
           Restricted-band band-edge Plot                          Authorized-band band-edge Plot




               Trace Green : Peak Plot                                           20dBc Plot
             Trace Purple : Average Plot

                                                       Vertical
           Restricted-band band-edge Plot                          Authorized-band band-edge Plot




              Trace Green : Peak Plot                                            20dBc Plot
            Trace Purple : Average Plot
* Final result of restricted band edge was shown in tabular data.




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                                                         Test report No.                     : 12219846H-A
                                                                                                         Page                                : 23 of 34
                                                                                                         Issued date                         : May 11, 2018
                                                                                                         FCC ID                              : AK8M18DFT1


                                                        Radiated Spurious Emission

 Report No.                          12219846H
 Test place                          Ise EMC Lab.
 Semi Anechoic Chamber               No.3                  No.3                                           No.3                                 No.3
 Date                                March 18, 2018        March 22, 2018                                 March 25, 2018                       March 27, 2018
 Temperature / Humidity              23 deg. C / 36 % RH   20 deg. C / 38 % RH                            22 deg. C / 31 % RH                  25 deg. C / 33 % RH
 Engineer                            Tomoki Matsui         Takumi Shimada                                 Takafumi Noguchi                     Masafumi Niwa
                                     (1 GHz - 10 GHz)      (10 GHz - 18 GHz)                              (18 GHz - 26.5 GHz)                  (Below 1 GHz)
 Mode                                Tx, Hopping Off, 3DH5 2441 MHz

           Polarity Frequency Detector Reading Ant.Fac. Loss                Gain Duty Factor Result            Limit  Margin                 Remark
           消すな         [MHz]                [dBuV] [dB/m]          [dB]      [dB]      [dB]     [dBuV/m] [dBuV/m] [dB]
          Hori           45.300 QP             22.4       12.2        7.4      32.2           -        9.8       40.0   30.2
          Hori          129.000 QP             23.8       13.5        8.5      32.2           -       13.6       43.5   29.9
          Hori          244.000 QP             21.4       11.5        9.6      32.0           -       10.5       46.0   35.5
          Hori          501.400 QP             21.3       17.5       11.3      32.0           -       18.1       46.0   27.9
          Hori          833.663 QP             21.2       21.1       13.2      31.3           -       24.2       46.0   21.8
          Hori          968.370 QP             20.2       22.2       13.8      30.6           -       25.6       53.9   28.3
          Hori         3661.566 PK             42.4       29.6        8.9      32.2           -       48.7       73.9   25.2
          Hori         4882.000 PK             40.6       31.9        9.0      31.7           -       49.8       73.9   24.1   Floor noise
          Hori         7323.000 PK             42.1       36.2       10.4      32.7           -       56.0       73.9   17.9   Floor noise
          Hori         9764.000 PK             42.3       38.7       11.0      33.4           -       58.6       73.9   15.3   Floor noise
          Hori         3661.566 AV             31.2       29.6        8.9      32.2           -       37.5       53.9   16.4
          Hori         4882.000 AV             28.2       31.9        9.0      31.7           -       37.4       53.9   16.5   Floor noise
          Hori         7323.000 AV             29.9       36.2       10.4      32.7           -       43.8       53.9   10.1   Floor noise
          Hori         9764.000 AV             29.8       38.7       11.0      33.4           -       46.1       53.9    7.8   Floor noise
          Vert           45.300 QP             22.3       12.2        7.4      32.2           -        9.7       40.0   30.3
          Vert          129.000 QP             23.2       13.5        8.5      32.2           -       13.0       43.5   30.5
          Vert          244.000 QP             21.3       11.5        9.6      32.0           -       10.4       46.0   35.6
          Vert          501.400 QP             21.3       17.5       11.3      32.0           -       18.1       46.0   27.9
          Vert          833.663 QP             21.1       21.1       13.2      31.3           -       24.1       46.0   21.9
          Vert          968.370 QP             20.2       22.2       13.8      30.6           -       25.6       53.9   28.3
          Vert         3661.566 PK             42.2       29.6        8.9      32.2           -       48.5       73.9   25.4
          Vert         4882.000 PK             41.5       31.9        9.0      31.7           -       50.7       73.9   23.2   Floor noise
          Vert         7323.000 PK             43.1       36.2       10.4      32.7           -       57.0       73.9   16.9   Floor noise
          Vert         9764.000 PK             42.1       38.7       11.0      33.4           -       58.4       73.9   15.5   Floor noise
          Vert         3661.566 AV             30.6       29.6        8.9      32.2           -       36.9       53.9   17.0
          Vert         4882.000 AV             28.3       31.9        9.0      31.7           -       37.5       53.9   16.4   Floor noise
          Vert         7323.000 AV             29.9       36.2       10.4      32.7           -       43.8       53.9   10.1   Floor noise
          Vert         9764.000 AV             30.0       38.7       11.0      33.4           -       46.3       53.9    7.6   Floor noise
          Result = Reading + Ant Factor + Loss (Cable+Attenuator+Filter+Distance factor(above 1 GHz)) - Gain(Amplifier)
          *Other frequency noises omitted in this report were not seen or had enough margin (more than 20 dB).
          消すな
          Distance factor:      1 GHz - 10 GHz        20log (4.5 m / 3.0 m) = 3.53 dB
          消すな                   10 GHz - 26.5 GHz 20log (1.0 m / 3.0 m) = -9.5 dB

                                 *These results have sufficient margin without taking account Dwell time factor.




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                                                         Test report No.                     : 12219846H-A
                                                                                                         Page                                : 24 of 34
                                                                                                         Issued date                         : May 11, 2018
                                                                                                         FCC ID                              : AK8M18DFT1


                                                        Radiated Spurious Emission

 Report No.                          12219846H
 Test place                          Ise EMC Lab.
 Semi Anechoic Chamber               No.3                  No.3                                           No.3                                 No.3
 Date                                March 18, 2018        March 22, 2018                                 March 25, 2018                       March 27, 2018
 Temperature / Humidity              23 deg. C / 36 % RH   20 deg. C / 38 % RH                            22 deg. C / 31 % RH                  25 deg. C / 33 % RH
 Engineer                            Tomoki Matsui         Takumi Shimada                                 Takafumi Noguchi                     Masafumi Niwa
                                     (1 GHz - 10 GHz)      (10 GHz - 18 GHz)                              (18 GHz - 26.5 GHz)                  (Below 1 GHz)
 Mode                                Tx, Hopping Off, 3DH5 2480 MHz

           Polarity Frequency Detector Reading Ant.Fac. Loss                Gain Duty Factor Result            Limit  Margin                 Remark
           消すな         [MHz]                [dBuV] [dB/m]          [dB]      [dB]      [dB]     [dBuV/m] [dBuV/m] [dB]
          Hori           45.300 QP             22.2       12.2        7.4      32.2           -        9.6       40.0   30.4
          Hori          129.000 QP             23.9       13.5        8.5      32.2           -       13.7       43.5   29.8
          Hori          244.000 QP             21.3       11.5        9.6      32.0           -       10.4       46.0   35.6
          Hori          501.400 QP             21.3       17.5       11.3      32.0           -       18.1       46.0   27.9
          Hori          833.663 QP             21.2       21.1       13.2      31.3           -       24.2       46.0   21.8
          Hori          968.370 QP             20.3       22.2       13.8      30.6           -       25.7       53.9   28.2
          Hori         2483.500 PK             42.6       27.8        6.8      32.7           -       44.5       73.9   29.4
          Hori         3719.948 PK             41.7       29.6        9.0      32.2           -       48.1       73.9   25.8
          Hori         4960.000 PK             41.0       32.1        9.1      31.7           -       50.5       73.9   23.4   Floor noise
          Hori         7440.000 PK             41.8       36.4       10.3      32.7           -       55.8       73.9   18.1   Floor noise
          Hori         9920.000 PK             42.1       38.9       11.0      33.4           -       58.6       73.9   15.3   Floor noise
          Hori         2483.500 AV             30.5       27.8        6.8      32.7           -       32.4       53.9   21.5
          Hori         3719.948 AV             30.2       29.6        9.0      32.2           -       36.6       53.9   17.3
          Hori         4960.000 AV             28.5       32.1        9.1      31.7           -       38.0       53.9   15.9   Floor noise
          Hori         7440.000 AV             30.0       36.4       10.3      32.7           -       44.0       53.9    9.9   Floor noise
          Hori         9920.000 AV             29.9       38.9       11.0      33.4           -       46.4       53.9    7.5   Floor noise
          Vert           45.300 QP             22.1       12.2        7.4      32.2           -        9.5       40.0   30.5
          Vert          129.000 QP             23.3       13.5        8.5      32.2           -       13.1       43.5   30.4
          Vert          244.000 QP             21.4       11.5        9.6      32.0           -       10.5       46.0   35.5
          Vert          501.400 QP             21.4       17.5       11.3      32.0           -       18.2       46.0   27.8
          Vert          833.663 QP             21.3       21.1       13.2      31.3           -       24.3       46.0   21.7
          Vert          968.370 QP             20.2       22.2       13.8      30.6           -       25.6       53.9   28.3
          Vert         2483.500 PK             43.1       27.8        6.8      32.7           -       45.0       73.9   28.9
          Vert         3719.948 PK             41.9       29.6        9.0      32.2           -       48.3       73.9   25.6
          Vert         4960.000 PK             40.7       32.1        9.1      31.7           -       50.2       73.9   23.7   Floor noise
          Vert         7440.000 PK             42.3       36.4       10.3      32.7           -       56.3       73.9   17.6   Floor noise
          Vert         9920.000 PK             42.7       38.9       11.0      33.4           -       59.2       73.9   14.7   Floor noise
          Vert         2483.500 AV             30.5       27.8        6.8      32.7           -       32.4       53.9   21.5
          Vert         3719.948 AV             29.3       29.6        9.0      32.2           -       35.7       53.9   18.2
          Vert         4960.000 AV             28.4       32.1        9.1      31.7           -       37.9       53.9   16.0   Floor noise
          Vert         7440.000 AV             30.1       36.4       10.3      32.7           -       44.1       53.9    9.8   Floor noise
          Vert         9920.000 AV             30.0       38.9       11.0      33.4           -       46.5       53.9    7.4   Floor noise
          Result = Reading + Ant Factor + Loss (Cable+Attenuator+Filter+Distance factor(above 1 GHz)) - Gain(Amplifier)
          *Other frequency noises omitted in this report were not seen or had enough margin (more than 20 dB).
          消すな
          Distance factor:      1 GHz - 10 GHz        20log (4.5 m / 3.0 m) = 3.53 dB
          消すな                   10 GHz - 26.5 GHz 20log (1.0 m / 3.0 m) = -9.5 dB

                                 *These results have sufficient margin without taking account Dwell time factor.




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                        Test report No.   : 12219846H-A
                                                                        Page              : 25 of 34
                                                                        Issued date       : May 11, 2018
                                                                        FCC ID            : AK8M18DFT1


                                        Radiated Spurious Emission
                                       (Reference Plot for band-edge)

            Report No.                 12219846H
            Test place                 Ise EMC Lab.
            Semi Anechoic Chamber      No.3
            Date                       March 18, 2018
            Temperature / Humidity     23 deg. C / 36 % RH
            Engineer                   Tomoki Matsui
                                       (1 GHz - 10 GHz)
            Mode                       Tx, Hopping Off, 3DH5 2480 MHz


                                                 Horizontal
                                       Restricted-band band-edge Plot




                                           Trace Green : Peak Plot
                                         Trace Purple : Average Plot

                                                   Vertical
                                       Restricted-band band-edge Plot




                                       Trace Green : Peak Plot
                                     Trace Purple : Average Plot
* Final result of restricted band edge was shown in tabular data.




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                                                          Test report No.          : 12219846H-A
                                                                                                          Page                     : 26 of 34
                                                                                                          Issued date              : May 11, 2018
                                                                                                          FCC ID                   : AK8M18DFT1


                                                                     Radiated Spurious Emission
                                                                       (Plot data, Worst case)

 Report No.                                           12219846H
 Test place                                           Ise EMC Lab.
 Semi Anechoic Chamber                                No.3                  No.3                            No.3                        No.3
 Date                                                 March 18, 2018        March 22, 2018                  March 25, 2018              March 27, 2018
 Temperature / Humidity                               23 deg. C / 36 % RH   20 deg. C / 38 % RH             22 deg. C / 31 % RH         25 deg. C / 33 % RH
 Engineer                                             Tomoki Matsui         Takumi Shimada                  Takafumi Noguchi            Masafumi Niwa
                                                      (1 GHz - 10 GHz)      (10 GHz - 18 GHz)               (18 GHz - 26.5 GHz)         (Below 1 GHz)
 Mode                                                 Tx, Hopping Off, 3DH5 2402 MHz



                                                                                      Horizontal
                                            80

                                            70

                                            60
                  Field strength [dBuV/m]




                                            50

                                            40

                                            30

                                            20

                                            10

                                            0
                                                 10                   100                         1000                10000
                                                                                       Frequency [MHz]

                                                      QP      Peak          Average         QP Limit     Peak Limit     Average Limit




                                                                                       Vertical
                                            80

                                            70

                                            60
                  Field strength [dBuV/m]




                                            50

                                            40

                                            30

                                            20

                                            10

                                            0
                                                 10                   100                         1000                10000
                                                                                       Frequency [MHz]

                                                      QP      Peak          Average         QP Limit     Peak Limit     Average Limit



*These plots data contains sufficient number to show the trend of characteristic features for EUT.




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                                                        Test report No.        : 12219846H-A
                                                                                                        Page                   : 27 of 34
                                                                                                        Issued date            : May 11, 2018
                                                                                                        FCC ID                 : AK8M18DFT1


                                                        Radiated Spurious Emission

             Report No.                              12219846H
             Test place                              Ise EMC Lab. No.3 Semi Anechoic Chamber
             Date                                    March 20, 2018
             Temperature / Humidity                  23deg. C / 40 % RH
             Engineer                                Takumi Shimada
                                                     (1 GHz -10 GHz)
             Mode                                    Tx, Hopping Off, 3DH5 2402 MHz and 11ac-40 5550 MHz

           Polarity Frequency Detector Reading Ant.Fac. Loss                Gain     Duty Factor Result        Limit  Margin   Remark
           消すな         [MHz]                [dBuV] [dB/m]          [dB]      [dB]       [dB]      [dBuV/m] [dBuV/m] [dB]
          Hori         2390.000 PK             42.4       27.7        6.7      32.7             -     44.1       73.9   29.8
          Hori         2390.000 AV             29.7       27.7        6.7      32.7             -     31.4       53.9   22.5
          Vert         2390.000 PK             41.9       27.7        6.7      32.7             -     43.6       73.9   30.3
          Vert         2390.000 AV             29.5       27.7        6.7      32.7             -     31.2       53.9   22.7
          Result = Reading + Ant Factor + Loss (Cable+Attenuator+Filter+Distance factor(above 1 GHz)) - Gain(Amplifier)
          *Other frequency noises omitted in this report were not seen or had enough margin (more than 20 dB).
          消すな
          Distance factor:      1 GHz - 10 GHz        20log (4.5 m / 3.0 m) = 3.53 dB



           20dBc Data Sheet
           Polarity  Frequency Detector Reading        Ant      Loss      Gain     Result    Limit   Margin       Remark
                                                      Factor
                        [MHz]               [dBuV] [dB/m]       [dB]      [dB] [dBuV/m][dBuV/m] [dB]
           Hori        2402.000 PK             93.0     27.7       6.8      32.7      94.8         -         - Carrier
           Hori        2400.000 PK             37.1     27.7       6.8      32.7      38.9     74.8      35.9
           Vert        2402.000 PK             91.2     27.7       6.8      32.7      93.0         -         - Carrier
           Vert        2400.000 PK             35.4     27.7       6.8      32.7      37.2     73.0      35.8
           Result = Reading + Ant Factor + Loss (Cable+Attenuator+Filter+Distance factor(above 1 GHz)) - Gain(Amprifier)




                                *These results have sufficient margin without taking account Dwell time factor.




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                                                         Test report No.                     : 12219846H-A
                                                                                                         Page                                : 28 of 34
                                                                                                         Issued date                         : May 11, 2018
                                                                                                         FCC ID                              : AK8M18DFT1


                                                        Radiated Spurious Emission

 Report No.                          12219846H
 Test place                          Ise EMC Lab. No.3 Semi Anechoic Chamber
 Date                                March 20, 2018         March 22, 2018        March 25, 2018                                               March 28, 2018
 Temperature / Humidity              23deg. C / 40 % RH     20 deg. C / 38 % RH   22 deg. C / 31 % RH                                          18 deg. C / 42 % RH
 Engineer                            Takumi Shimada         Takumi Shimada        Takafumi Noguchi                                             Takafumi Noguchi
                                     (1 GHz -10 GHz)        (10 GHz - 18 GHz)     (18 GHz - 26.5 GHz)                                          (Below 1 GHz)
 Mode                                Tx, Hopping Off, 3DH5 2441 MHz and 11ac-40 5550 MHz

           Polarity Frequency Detector Reading Ant.Fac. Loss                Gain Duty Factor Result            Limit  Margin                 Remark
           消すな         [MHz]                [dBuV] [dB/m]          [dB]      [dB]      [dB]     [dBuV/m] [dBuV/m] [dB]
          Hori           50.145 QP             24.9       10.6        7.5      32.2           -       10.8       40.0   29.2
          Hori          107.713 QP             39.3       11.1        8.3      32.2           -       26.5       43.5   17.0
          Hori          130.000 QP             33.7       13.6        8.5      32.2           -       23.6       43.5   19.9
          Hori          193.144 QP             36.9       16.4        9.1      32.1           -       30.3       43.5   13.2
          Hori          247.000 QP             37.9       11.5        9.6      32.0           -       27.0       46.0   19.0
          Hori          271.142 QP             42.7       12.3        9.8      32.0           -       32.8       46.0   13.2
          Hori         3699.978 PK             44.1       29.6        8.9      32.2           -       50.4       73.9   23.5
          Hori         4882.000 PK             40.5       31.9        9.0      31.7           -       49.7       73.9   24.2   Floor noise
          Hori         7323.000 PK             43.2       36.2       10.4      32.7           -       57.1       73.9   16.8   Floor noise
          Hori         9764.000 PK             42.2       38.7       11.0      33.4           -       58.5       73.9   15.4   Floor noise
          Hori         3699.978 AV             36.7       29.6        8.9      32.2           -       43.0       53.9   10.9
          Hori         4882.000 AV             28.3       31.9        9.0      31.7           -       37.5       53.9   16.4   Floor noise
          Hori         7323.000 AV             29.8       36.2       10.4      32.7           -       43.7       53.9   10.2   Floor noise
          Hori         9764.000 AV             29.9       38.7       11.0      33.4           -       46.2       53.9    7.7   Floor noise
          Vert           50.145 QP             36.2       10.6        7.5      32.2           -       22.1       40.0   17.9
          Vert          107.713 QP             35.8       11.1        8.3      32.2           -       23.0       43.5   20.5
          Vert          130.000 QP             34.0       13.6        8.5      32.2           -       23.9       43.5   19.6
          Vert          193.144 QP             33.0       16.4        9.1      32.1           -       26.4       43.5   17.1
          Vert          247.000 QP             28.4       11.5        9.6      32.0           -       17.5       46.0   28.5
          Vert          271.142 QP             35.4       12.3        9.8      32.0           -       25.5       46.0   20.5
          Vert         3699.978 PK             43.3       29.6        8.9      32.2           -       49.6       73.9   24.3
          Vert         4882.000 PK             40.6       31.9        9.0      31.7           -       49.8       73.9   24.1   Floor noise
          Vert         7323.000 PK             43.2       36.2       10.4      32.7           -       57.1       73.9   16.8   Floor noise
          Vert         9764.000 PK             42.1       38.7       11.0      33.4           -       58.4       73.9   15.5   Floor noise
          Vert         3699.978 AV             35.1       29.6        8.9      32.2           -       41.4       53.9   12.5
          Vert         4882.000 AV             28.3       31.9        9.0      31.7           -       37.5       53.9   16.4   Floor noise
          Vert         7323.000 AV             29.9       36.2       10.4      32.7           -       43.8       53.9   10.1   Floor noise
          Vert         9764.000 AV             29.9       38.7       11.0      33.4           -       46.2       53.9    7.7   Floor noise
          Result = Reading + Ant Factor + Loss (Cable+Attenuator+Filter+Distance factor(above 1 GHz)) - Gain(Amplifier)
          *Other frequency noises omitted in this report were not seen or had enough margin (more than 20 dB).
          消すな
          Distance factor:      1 GHz - 10 GHz        20log (4.5 m / 3.0 m) = 3.53 dB
          消すな                   10 GHz - 26.5 GHz 20log (1.0 m / 3.0 m) = -9.5 dB



                                 *These results have sufficient margin without taking account Dwell time factor.




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                                                         Test report No.       : 12219846H-A
                                                                                                         Page                  : 29 of 34
                                                                                                         Issued date           : May 11, 2018
                                                                                                         FCC ID                : AK8M18DFT1


                                                        Radiated Spurious Emission

             Report No.                               12219846H
             Test place                               Ise EMC Lab. No.3 Semi Anechoic Chamber
             Date                                     March 20, 2018
             Temperature / Humidity                   23deg. C / 40 % RH
             Engineer                                 Takumi Shimada
                                                      (1 GHz -10 GHz)
             Mode                                     Tx, Hopping Off, 3DH5 2480 MHz and 11ac-40 5550 MHz

           Polarity Frequency Detector Reading Ant.Fac. Loss                Gain Duty Factor Result            Limit  Margin   Remark
           消すな         [MHz]                [dBuV] [dB/m]          [dB]      [dB]      [dB]     [dBuV/m] [dBuV/m] [dB]
          Hori         2483.500 PK             42.4       27.8        6.8      32.7           -       44.3       73.9   29.6
          Hori         2483.500 AV             28.8       27.8        6.8      32.7           -       30.7       53.9   23.2
          Vert         2483.500 PK             43.6       27.8        6.8      32.7           -       45.5       73.9   28.4
          Vert         2483.500 AV             29.2       27.8        6.8      32.7           -       31.1       53.9   22.8
          Result = Reading + Ant Factor + Loss (Cable+Attenuator+Filter+Distance factor(above 1 GHz)) - Gain(Amplifier)
          *Other frequency noises omitted in this report were not seen or had enough margin (more than 20 dB).
          消すな
          Distance factor:      1 GHz - 10 GHz        20log (4.5 m / 3.0 m) = 3.53 dB



                                 *These results have sufficient margin without taking account Dwell time factor.




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                                Test report No.        : 12219846H-A
                                                                                Page                   : 30 of 34
                                                                                Issued date            : May 11, 2018
                                                                                FCC ID                 : AK8M18DFT1


APPENDIX 2: Test instruments

Test equipment
  Control No.        Instrument         Manufacturer             Model No          Serial No      Test Item Calibration Date *
                                                                                                             Interval(month)
   MAEC-03      Semi Anechoic           TDK            Semi Anechoic Chamber      DA-10005        RE        2017/10/31 * 12
                Chamber(NSA)                           3m
   MOS-13       Thermo-Hygrometer       Custom         CTH-180                    1301            RE        2018/01/24 * 12
   MJM-16       Measure                 KOMELON        KMC-36                     -               RE        -
 COTS-MEMI      EMI measurement         TSJ            TEPTO-DV                   -               RE        -
                program
   MSA-03       Spectrum Analyzer       Agilent        E4448A                    MY44020357       RE        2017/11/07 * 12
   MHA-20       Horn Antenna 1-18GHz    Schwarzbeck    BBHA9120D                 258              RE        2017/05/22 * 12
   MCC-167      Microwave Cable         Junkosha       MWX221                    1404S374(1m) /   RE        2017/05/29 * 12
                                                                                 1405S074(5m)
   MPA-11       MicroWave System        Agilent        83017A                    MY39500779       RE        2018/03/13 * 12
                Amplifier
   MHA-16       Horn Antenna 15-40GHz   Schwarzbeck    BBHA9170                   BBHA9170306 RE            2017/05/14 * 12
   MMM-08       DIGITAL HiTESTER        Hioki          3805                       051201197   RE            2018/01/09 * 12
   MHF-25       High Pass Filter        UL Japan       HPF SELECTOR               001         RE            2017/09/22 * 12
                3.5-18.0GHz
   MCC-224
   MPA-03       Microwave System        Agilent        83050A                     MY39500610      RE        2017/10/12 * 12
                Power Amplifier
   MHA-29       Horn Antenna            ETS            3160-10                    00152399        RE        2017/09/15 * 12
                26.5-40GHz              LINDGREN
   MPA-22       Pre Amplifier           MITEQ, Inc     AMF-6F-2600400-33-8P /    1871355     RE             2017/09/07 * 12
                                                       AMF-4F-2600400-33-8P      /1871328
   MHA-17       Horn Antenna 15-40GHz Schwarzbeck      BBHA9170                  BBHA9170307 RE             2017/06/30 * 12
   MTR-08       Test Receiver         Rohde &          ESCI                      100767      RE             2017/08/22 * 12
                                      Schwarz
   MBA-03       Biconical Antenna     Schwarzbeck      BBA9106                    1915            RE        2017/10/02 * 12
   MLA-22       Logperiodic           Schwarzbeck      VUSLP9111B                 911B-191        RE        2018/01/30 * 12
                Antenna(200-1000MHz)
   MCC-51       Coaxial cable         UL Japan         -                          -               RE        2017/07/12 * 12
   MAT-98       Attenuator            KEYSIGHT         8491A                      MY52462349      RE        2017/12/14 * 12
   MPA-13       Pre Amplifier         SONOMA           310                        260834          RE        2017/03/27 * 12
                                      INSTRUMENT
   MSA-13       Spectrum Analyzer     Agilent          E4440A                     MY46185823      AT        2017/11/16 * 12
   MAT-88       Attenuator            Weinschel        WA56-10                    56100304        AT        2017/06/12 * 12
                                      Associates
   MPM-09       Power Meter           Anritsu          ML2495A                    6K00003348      AT        2017/10/13 * 12
   MPSE-12      Power sensor          Anritsu          MA2411B                    011598          AT        2017/10/13 * 12
   MOS-19       Thermo-Hygrometer     Custom           CTH-201                    0001            AT        2017/12/21 * 12
   MMM-17       DIGIITAL HiTESTER     Hioki            3805                       070900530       AT        2018/01/15 * 12
   MCC-174      Microwave Cable       Junkosha         MWX221                     1409S497        AT        2017/03/13 * 12

The expiration date of the calibration is the end of the expired month.
All equipment is calibrated with valid calibrations. Each measurement data is traceable to the national or
international standards.

As for some calibrations performed after the tested dates, those test equipment have been controlled by means
of an unbroken chains of calibrations.

Test Item:           RE: Radiated Emission test
                     AT: Antenna Terminal Conducted tests




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124



Document Created: 2019-11-04 23:00:00
Document Modified: 2019-11-04 23:00:00

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC