Test Report

FCC ID: AJK8222532

Test Report

Download: PDF
FCCID_3678107

                                           849 NW State Road 45
                                           Newberry, Fl 32669 USA
                                           Phone: 888.472.2424 or
                                           352.472.5500
                                           Fax: 352.472.2030
                                           Email: info@timcoengr.com
                                           Website: www.timcoengr.com



                   FCC PART 15 B SUBPART B
                      RECEIVER TEST REPORT
                   Applicant             ROCKWELL COLLINS, INC.
                                   1300 WILSON BLVD. SUITE 200
                    Address
                                     ARLINGTON VA 22209 USA
                     FCC ID                    AJK8222532
    Product Description           GLU2100 LANDING UNIT RECEIVER
  Date Sample Received                          10/17/2017
             Date Tested                        10/18/2017
               Tested By                         Tim Royer
            Approved By                         Sid Sanders
             Test Results                 PASS                       FAIL


          Report               Version               Description              Issue Date
         Number                Number
    1821UT17TestReport          Rev1                 Initial Issue            10/24/2017
                                Rev2       Revised report – new test set up   12/7/2017
                                                    photo added
                                Rev2         Updated Power Information        12/13/2017




THE ATTACHED REPORT SHALL NOT BE REPRODUCED EXCEPT IN FULL
 WITHOUT THE WRITTEN APPROVAL OF TIMCO ENGINEERING, INC.


                                             TABLE OF CONTENTS

GENERAL REMARKS ............................................................................................................ 2

REPORT SUMMARY ............................................................................................................. 3

TEST ENVIRONMENT .......................................................................................................... 3

TEST SETUP SUMMARY ....................................................................................................... 3

RESULTS SUMMARY ............................................................................................................ 3

EUT SPECIFICATION ........................................................................................................... 4

TEST PROCEDURES ............................................................................................................ 5

RADIATED SPURIOUS EMISSIONS ........................................................................................ 6

  Test Data: 30–200 MHz Vertical Plot .................................................................................. 7
  Test Data: 30–200 MHz Vertical Plot Cont. ......................................................................... 8
  Test Data: 30–200 MHz Horizontal Plot .............................................................................. 9
  Test Data: 30–200 MHz Horizontal Plot Cont. .................................................................... 10
  Test Data: 200–1000 MHz Vertical Plot ............................................................................ 11
  Test Data: 200–1000 MHz Vertical Plot Cont. .................................................................... 12
  Test Data: 200–1000 MHz Horizontal Plot ......................................................................... 13
  Test Data: 200–1000 MHz Horizontal Plot Cont. ................................................................ 14
  Test Data: 1–12.5 GHz Vertical Plot ................................................................................. 15
  Test Data: 1–12.5 GHz Vertical Plot Cont. ........................................................................ 16
  Test Data: 1–12.5 GHz Horizontal Plot. ............................................................................ 17
  Test Data: 1–12.5 GHz Horizontal Plot Cont. ..................................................................... 18
TEST EQUIPMENT LIST ..................................................................................................... 19


GENERAL REMARKS

The attached report shall not be reproduced except in full without the written permission
of Timco Engineering Inc.


Summary

The device under test does:
      Fulfill the general approval requirements as identified in this test report and was
      selected by the customer.
      Not fulfill the general approval requirements as identified in this test report

Attestations

This equipment has been tested in accordance with the standards identified in this test
report. To the best of my knowledge and belief, these tests were performed using the
measurement procedures described in this report.

All instrumentation and accessories used to test products for compliance to the indicated
standards are calibrated regularly in accordance with ISO 17025 requirements.

I attest that the necessary measurements were made at:

Timco Engineering Inc.
849 NW State Road 45
Newberry, FL 32669




Tested by:
Name and Title: Tim Royer, Project Manager/Testing Engineer




Date: 10/24/2017



Reviewed and approved by:
Name and Title: Sid Sanders Engineer

Date: 10/27/2017



Applicant:   ROCKWELL COLLINS, INC.                           TABLE OF CONTENTS
FCC ID:      AJK8222532
Report:      1821UT17TestReport_Rev2                            Page 2 of 19


REPORT SUMMARY

                Disclaimer The test results only relate to the item tested.
      Applicable Rule(s) Pt 15.109, ANSI C63.4: 2013
             Related Report None



TEST ENVIRONMENT

                               Timco Engineering, Inc. 849 NW State Road 45
               Test Facility
                               Newberry, FL 32669 USA.
   Test Condition in the Temperature: 26ºC
             laboratory Relative humidity: 50%



TEST SETUP SUMMARY

                        The EUT was placed on the turntable per setup per ANSI
   Test Setup Diagram/
                        C63.4: 2013. A test set up photo is provided for
            Description
                        clarification.
     Deviation from the
                        No deviation
    standard/procedure
     Modification of EUT No modification



RESULTS SUMMARY

  FCC Rules 15.109 Radiated Emissions                           Pass
  FCC Rules 15.107- AC Powerline Conducted Emissions             N/A




Applicant:      ROCKWELL COLLINS, INC.                       TABLE OF CONTENTS
FCC ID:         AJK8222532
Report:         1821UT17TestReport_Rev2                        Page 3 of 19


EUT SPECIFICATION


         EUT Description       LANDING UNIT RECEIVER
                     FCC ID    AJK8222532
                                 115Vac/400Hz Single Phase
       EUT Power Source          DC Power
                                 Battery Operated Exclusively
                                 Prototype
                  Test Item      Pre-Production
                                 Production
                                 Fixed
      Type of Equipment          Mobile
                                 Portable
                 Laboratory    Temperature:   26ºC
             Test Conditions   Humidity:    55%
   Modifications to EUT:         No               Yes (explanation below)




Applicant:      ROCKWELL COLLINS, INC.                          TABLE OF CONTENTS
FCC ID:         AJK8222532
Report:         1821UT17TestReport_Rev2                           Page 4 of 19


TEST PROCEDURES


Radiation Interference: The test procedure used was ANSI C63.4 using a spectrum
analyzer with a preselector. The bandwidth of the spectrum analyzer was 100 kHz with
an appropriate sweep speed. The analyzer was calibrated in dB above a microvolt at the
output of the antenna. The video bandwidth was always greater than or equal to the
RBW.

The frequency was scanned from 30 MHz to 12.5 GHz. When an emission was found, the
table was rotated to produce the maximum signal strength. The EUT was measured in
three (3) orthogonal planes when necessary.

Formula of Conversion Factors: The field strength at 3m was established by adding
the meter reading of the spectrum analyzer (which is set to read in units of dBµV) to the
antenna correction factor supplied by the antenna manufacturer plus the coax loss. The
antenna correction factors are stated in terms of dB. The gain of the preselector was
accounted for in the spectrum analyzer meter reading.

Example:
Freq (MHz) Meter Reading      + ACF            +CL           = FS
33         20 dBµV            + 10.36 dB/m     +0.40 dB      =30.36 dBµV/m @ 3m

ANSI C63.4 Measurement Procedures: The unit under test was placed on a table
80 cm high and with dimensions of 1m by 1.5m. The table used for radiated
measurements is capable of continuous rotation. When an emission was found, the table
was rotated to produce the maximum signal strength. At this point, the antenna was
raised and lowered from 1m to 4m. The antenna was placed in both the horizontal and
verticals planes.




Applicant:   ROCKWELL COLLINS, INC.                       TABLE OF CONTENTS
FCC ID:      AJK8222532
Report:      1821UT17TestReport_Rev2                        Page 5 of 19


RADIATED SPURIOUS EMISSIONS

Rules Part No.:    15.109, IC RSS-GEN 7.1

Requirements:
                          Frequency MHz                       Limits
                             30 – 88           40.0 dBµV/m measured @ 3 meters
                            88 – 216           43.5 dBµV/m measured @ 3 meters
                            216 – 960          46.0 dBµV/m measured @ 3 meters
                            Above 960          54.0 dBµV/m measured @ 3 meters
Measurement Procedure: The test procedure used was ANSI C63.4 using a spectrum
analyzer with a preselector. The bandwidth of the spectrum analyzer was 100 kHz with
an appropriate sweep speed. The analyzer was calibrated in dB above a microvolt at the
output of the antenna. The video bandwidth was always greater than or equal to the
RBW.

The frequency was scanned from 30 MHz to 5.0 GHz. When an emission was found, the
table was rotated to produce the maximum signal strength. The EUT was measured in
three (3) orthogonal planes when applicable.




Applicant:   ROCKWELL COLLINS, INC.                     TABLE OF CONTENTS
FCC ID:      AJK8222532
Report:      1821UT17TestReport_Rev2                      Page 6 of 19


RADIATED SPURIOUS EMISSIONS
TEST DATA: 30–200 MHZ VERTICAL PLOT




Results Meets Requirements




Applicant:   ROCKWELL COLLINS, INC.    TABLE OF CONTENTS
FCC ID:      AJK8222532
Report:      1821UT17TestReport_Rev2     Page 7 of 19


RADIATED SPURIOUS EMISSIONS

TEST DATA: 30–200 MHZ VERTICAL PLOT CONT.




Results Meets Requirements




Applicant:   ROCKWELL COLLINS, INC.         TABLE OF CONTENTS
FCC ID:      AJK8222532
Report:      1821UT17TestReport_Rev2          Page 8 of 19


RADIATED SPURIOUS EMISSIONS

TEST DATA: 30–200 MHZ HORIZONTAL PLOT




Results Meets Requirements




Applicant:   ROCKWELL COLLINS, INC.     TABLE OF CONTENTS
FCC ID:      AJK8222532
Report:      1821UT17TestReport_Rev2      Page 9 of 19


RADIATED SPURIOUS EMISSIONS

TEST DATA: 30–200 MHZ HORIZONTAL PLOT CONT.




Results Meets Requirements




Applicant:   ROCKWELL COLLINS, INC.           TABLE OF CONTENTS
FCC ID:      AJK8222532
Report:      1821UT17TestReport_Rev2            Page 10 of 19


RADIATED SPURIOUS EMISSIONS
TEST DATA: 200–1000 MHZ VERTICAL PLOT




Results Meets Requirements




Applicant:   ROCKWELL COLLINS, INC.     TABLE OF CONTENTS
FCC ID:      AJK8222532
Report:      1821UT17TestReport_Rev2      Page 11 of 19


RADIATED SPURIOUS EMISSIONS

TEST DATA: 200–1000 MHZ VERTICAL PLOT CONT.




Results Meets Requirements



Applicant:   ROCKWELL COLLINS, INC.           TABLE OF CONTENTS
FCC ID:      AJK8222532
Report:      1821UT17TestReport_Rev2            Page 12 of 19


RADIATED SPURIOUS EMISSIONS

TEST DATA: 200–1000 MHZ HORIZONTAL PLOT




Results Meets Requirements




Applicant:   ROCKWELL COLLINS, INC.       TABLE OF CONTENTS
FCC ID:      AJK8222532
Report:      1821UT17TestReport_Rev2        Page 13 of 19


RADIATED SPURIOUS EMISSIONS

TEST DATA: 200–1000 MHZ HORIZONTAL PLOT CONT.




Results Meets Requirements




Applicant:   ROCKWELL COLLINS, INC.             TABLE OF CONTENTS
FCC ID:      AJK8222532
Report:      1821UT17TestReport_Rev2              Page 14 of 19


RADIATED SPURIOUS EMISSIONS

TEST DATA: 1–12.5 GHZ VERTICAL PLOT




Results Meets Requirements




Applicant:   ROCKWELL COLLINS, INC.    TABLE OF CONTENTS
FCC ID:      AJK8222532
Report:      1821UT17TestReport_Rev2     Page 15 of 19


RADIATED SPURIOUS EMISSIONS

TEST DATA: 1–12.5 GHZ VERTICAL PLOT CONT.




Results Meets Requirements




Applicant:   ROCKWELL COLLINS, INC.         TABLE OF CONTENTS
FCC ID:      AJK8222532
Report:      1821UT17TestReport_Rev2          Page 16 of 19


RADIATED SPURIOUS EMISSIONS

TEST DATA: 1–12.5 GHZ HORIZONTAL PLOT.




Results Meets Requirements




Applicant:   ROCKWELL COLLINS, INC.      TABLE OF CONTENTS
FCC ID:      AJK8222532
Report:      1821UT17TestReport_Rev2       Page 17 of 19


RADIATED SPURIOUS EMISSIONS

TEST DATA: 1–12.5 GHZ HORIZONTAL PLOT CONT.




Results Meets Requirements




Applicant:   ROCKWELL COLLINS, INC.           TABLE OF CONTENTS
FCC ID:      AJK8222532
Report:      1821UT17TestReport_Rev2            Page 18 of 19


TEST EQUIPMENT LIST

   Device        Manufacturer       Model         Serial      Cal/Char         Due Date
                                                 Number         Date
  CHAMBER         Panashield         3M            N/A        04/25/16         12/31/17
  Antenna:       ETS-Lindgren       3117        00041534      03/01/17         03/01/19
   Double-
    Ridged
  Horn/ETS
    Horn 2
  Software:         Timco            N/A         Version         N/A             N/A
     Field                                       4.10.7.0
  Strength
   Program
  EMI Test         Rohde &         ESU 40        100320       04/01/16         04/01/18
Receiver R &       Schwarz
  S ESU 40
  Chamber
Coaxial Cable     Micro-Coax      Chamber 3    KMKM-0244-     08/09/16         08/09/18
- Chamber 3                        cable set    01; KMKM-
  cable set                        (Primary)     0670-00;
  (Primary)                                    KFKF-0198-
                                                    01
Band Reject      Micro-Tronics   BRM50702-02      -G042       09/27/16         09/27/18
  Filter 2.4
     GHz
  Antenna:          EMCO            3116        9011-2145     11/18/15         11/18/17
  Double-
Ridged Horn
 18-40 GHz
  Pre-amp         RF-LAMBDA      RLNA00M45GA        NA        01/04/16         01/04/18




*EMI RECEIVER SOFTWARE VERSION

The receiver firmware used was version 4.43 Service Pack 3




Applicant:      ROCKWELL COLLINS, INC.                       TABLE OF CONTENTS
FCC ID:         AJK8222532
Report:         1821UT17TestReport_Rev2                        Page 19 of 19



Document Created: 2017-12-13 16:35:42
Document Modified: 2017-12-13 16:35:42

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC