Test Report

FCC ID: AJK5972410

Test Report

Download: PDF
FCCID_3726020

RR051-17-100875-1-A Ed. 0




                                          Certification Radio test report

                                                         According to the standard:
                                                           CFR 47 FCC PART 15


                                                             Equipment under test:
                                               PERIMETER SURVEILLANCE RADAR


                                                              FCC ID: AJK5972410


                                                                        Company:
                                                     ROCKWELL COLLINS FRANCE




Distribution: Mr DE PABLO                                                                  (Company: ROCKWELL COLLINS FRANCE)


                                                                                           Number of pages: 32 with 4 appendixes

                                                                          Technical Verification and
       Ed.                    Date                 Modified                   Quality Approval
                                                   Page(s) Name and Function                                                                     Visa
        0                 1-Sep-17                 Creation M. DUMESNIL, Radio Technical Manager



Duplication of this document is only permitted for an integral photographic facsimile. It includes the number of pages referenced here above.
This document is the result of testing a specimen or a sample of the product submitted. It does not imply an assessment of the conformity of the whole manufactured
products of the tested sample.




  Siège Social : Emitech - 3, rue des Coudriers - Z.A. de l’Observatoire - 78180 MONTIGNY LE BX - France
  Siret : 344 545 645 00022 - Tél. : 33 (0)1 30 57 55 55 - Fax : 33 (0)1 30 43 74 48 - E-mail : contact@emitech.fr - URL : www.emitech.fr                   ACCREDITATIONS N°
                                                                                                                                                                1-0107, 1-0826,
  S.A. au capital de 1 560 000 € - R.C.S. VERSAILLES 344 545 645 - APE 7112B                                                                                    1-0827,1-1925,
                                                                                                                                                                1-2069,1-2070,
                                                                                                                                                               1-2376 & 1-6086
                                                                                                                                                                  LISTE DES SITES ACCREDITES ET
                                                                                                                                                                                       PORTEES
                                                                                                                                                              DISPONIBLES SUR WWW.COFRAC.FR


                                                                       RR051-17-100875-1-A Ed. 0




DESIGNATION OF PRODUCT:            PERIMETER SURVEILLANCE RADAR


Serial number (S/N):               TRN005


Reference / model (P/N):           PSR-500


Software version:




MANUFACTURER:                      ROCKWELL COLLINS FRANCE



COMPANY SUBMITTING THE PRODUCT:

Company:                           ROCKWELL COLLINS FRANCE


Address:                           6, AVENUE DIDIER DAURAT
                                   PARC INDUSTRIEL AEROPORTUAIRE
                                   31707 BLAGNAC CEDEX 01
                                   FRANCE

Responsible:                       Mr DE PABLO

Person present during the tests:   Mr GAYRAUD


DATES OF TEST:                     From 3-Jul-17 to 4-Jul-17



TESTING LOCATION:                  EMITECH ANGERS laboratory at JUIGNE SUR LOIRE (49) FRANCE
                                   FCC Accredited under US-EU MRA Designation Number: FR0009
                                   Test Firm Registration Number: 873677


TESTED BY:                         S. LOUIS                    VISA:

WRITTEN BY:                        S. LOUIS




                                              Page 2/32


                                                                                                                            RR051-17-100875-1-A Ed. 0




                                                                     CONTENTS


                        TITLE                                                                                                                                PAGE

1.      INTRODUCTION ....................................................................................................................................... 4
2.      PRODUCT DESCRIPTION ....................................................................................................................... 4
3.      NORMATIVE REFERENCE ...................................................................................................................... 4
4.      TEST METHODOLOGY ............................................................................................................................ 5
5.      TEST EQUIPMENT CALIBRATION DATES ............................................................................................ 6
6.      TESTS AND CONCLUSIONS ................................................................................................................... 7
7.      MEASUREMENT UNCERTAINTY ...........................................................................................................10
8.      MEASUREMENT OF THE CONDUCTED DISTURBANCES ..................................................................11
9.      RADIATED EMISSION LIMITS ................................................................................................................15
10.     MEASUREMENT OF THE CONDUCTED DISTURBANCES ..................................................................17
11.     ADDITIONAL PROVISIONS TO THE GENERAL RADIATED EMISSION LIMITATIONS ......................21
12.     FUNDAMENTAL AND HARMONICS FIELD STRENGTH ......................................................................22
13.     OUT-OF-BAND EMISSIONS ...................................................................................................................24
APPENDIX 1: PHOTOS OF THE EQUIPMENT UNDER TEST........................................................................................ 26
APPENDIX 2: TEST SET UP ............................................................................................................................................ 27
APPENDIX 3: TEST EQUIPMENT LIST ........................................................................................................................... 28
APPENDIX 4: BAND EDGE .............................................................................................................................................. 31




                                                                            Page 3/32


                                                                                    RR051-17-100875-1-A Ed. 0




1.       INTRODUCTION

This document presents the result of RADIO test carried out on the following equipment:
Perimeter Surveillance Radar PSR-500, in accordance with normative reference.



2.       PRODUCT DESCRIPTION

Class:                         B

Utilization:                   Perimeter Surveillance Radar

Antenna type and gain:         Network Patch Antenna with a gain of 10dBi

Operating frequency range:     From 5.750GHz to 5.850GHz

Number of channels:            Continuous sweep between 5750MHz and 5850MHz

Modulation:                    None (FMCW)

Power source:                  48Vdc by POE supplied with 120Vac / 60Hz

Power level, frequency range and channels characteristics are not user adjustable.
The details pictures of the product and the circuit boards are joined with this file.



3.       NORMATIVE REFERENCE

The standards and testing methods related throughout this report are those listed below.
They are applied on the whole test report even though the extensions (version, date and amendment) are not
repeated.

CFR 47 FCC Part 15 (2017)          Radio Frequency Devices


ANSI C63.4                         2014
                                   Methods of measurement of Radio-Noise
                                   Emissions from low-voltage Electrical and Electronic Equipment in the Range
                                   of 9 kHz to 40 GHz.


ANSI C63.10                        2013
                                   Testing Unlicensed Wireless Devices.




                                                    Page 4/32


                                                                              RR051-17-100875-1-A Ed. 0




4.    TEST METHODOLOGY

Radio performance tests procedures given in CFR 47 part 15:

Subpart A –General
              Paragraph 19:     labelling requirements
              Paragraph 21:     information to user

Subpart B –Unintentional Radiators
               Paragraph 105: information to the user
               Paragraph 107: Conducted limits
               Paragraph 109: Radiated emission limits
               Paragraph 111: Antenna power conduction limits for receivers

Subpart C – Intentional Radiators
                Paragraph 203: Antenna requirement
                Paragraph 205: Restricted bands of operation
                Paragraph 207: Conducted limits
                Paragraph 209: Radiated emission limits; general requirements
                Paragraph 215: Additional provisions to the general radiated emission limitations
                Paragraph 249: Operation within the bands 902-928 MHZ, 2400-2483.5 MHz, 5725-5850
                                  MHz and 24.0-24.25 GHz.




                                                Page 5/32


                                                                               RR051-17-100875-1-A Ed. 0




5.     TEST EQUIPMENT CALIBRATION DATES

                                                                                                Next
 Emitech                                                            Last       Calibration
                    Model                      Type                                          calibration
 Number                                                          calibration    interval
                                                                                               due (1)
     0000    BAT-EMC V3.6.0.32               Software                 /             /             /
     1406         EMCO 6502                Loop antenna          13/04/2017      2 years     13/06/2019
                 Microwave DB
     1922                               Low-noise amplifier      21/12/2016       1 year     21/02/2018
                C020180F-4B1
     4087   Filtek LP03/1000-7GH          Low Pass Filter        05/04/2016      2 years     05/06/2018
     4088         R&S FSP40             Spectrum Analyzer        29/10/2015      2 years     29/12/2017
     4354    ALC ALS2640-30-10          Low-noise amplifier      18/11/2016      1 year      18/01/2018
               Microtronics LPM
     6606                                 Low Pass Filter        12/05/2015      2 years     12/07/2017
                     15601
               Microtronics HPM
     6607                                 High Pass Filter       12/05/2015      2 years     12/07/2017
                     15600
     7190         R&S HL223                  Antenna             15/03/2016      3 years     15/05/2019
     7240          Emco 3110             Biconical antenna       15/03/2016      3 years     15/11/2019
     7566         Testo 608-Hi             Meteo station         15/02/2016      2 years     15/04/2018
            California instruments
     8508                                  Power source          12/12/2016       1 year     12/02/2018
                    1251RP
     8635          R&S EZ-25              High-pass filter       27/10/2016      2 years     27/12/2018
     8676    ISOTECH IDM106N                Multimeter           21/05/2015      2 years     21/07/2017
                  LUCIX Corp
     8704                               Low-noise amplifier      02/05/2017       1 year     02/07/2018
             S180265L3201 LNA
                Thurbly Thandar
     8719                                      LISN              06/04/2016      2 years     06/06/2018
               Instruments 1600
     8720        R&S ESH3-Z5                   LISN              28/11/2016      2 years     28/01/2019
            La Crosse Technology
     8750                                  Meteo station         23/09/2016      2 years     23/11/2018
                    WS-9232
                                       Satellite synchronized
     8896     ACQUISYS GPS8                                           /             /             /
                                        frequency standard
     9266    Pasternack PE7004-10         Attenuator 10dB        12/04/2016      2 years     12/06/2018
     9403          R&S ESU8             Spectrum Analyzer        11/08/2016      2 years     11/10/2018
                 Absorber sheath
   9489                                        Emitech           21/04/2016      2 years     21/06/2018
                      current
                 Mini Circuit ZFL-
  10730                                 Low-noise amplifier      21/11/2016       1 year     21/01/2018
                     1000LN
                   LUCIX Corp
  10739                                 Low-noise amplifier      29/03/2017       1 year     29/05/2018
                 S005180M3201
  10759           SIDT Cage 3            Anechoic chamber             /             /             /
  10771            EMCO 3117                   Antenna           23/11/2016      3 years     23/01/2020
  10788              Emitech          Outside room Hors cage          /             /             /
     /             GPIB SHOT                   Software               /             /             /
(1) according tolerance of ±2 months apply for all equipments.


                                                 Page 6/32


                                                                                                   RR051-17-100875-1-A Ed. 0




6.     TESTS AND CONCLUSIONS

6.1 general


        Test                            Description of test                             Respected criteria?                 Comment
     procedure                                                                        Yes No NAp NAs

FCC Part 15.19       LABELLING REQUIREMENTS                                                                              See certification
                                                                                        X
                                                                                                                         documents

                                                                                                                         See certification
FCC Part 15.21 INFORMATION TO USER                                                      X
                                                                                                                         documents

NAp: Not Applicable                    NAs: Not Asked


     LABEL SHALL CONTAIN
       The label shall be located in a conspicuous location on the device
       The label shall not be a stick-on, paper label. The label on these products shall be permanently affixed to the product and
       shall be readily visible to the purchaser at the time of purchase

§15.19: (can be placed in the user manual if the product is too small)
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1)
this device may not cause harmful interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.


     USER NOTICE SHALL CONTAIN

The user notice, not provided during tests, shall include the following informations:

§15.21:
Any changes or modifications to this equipment not expressly approved by ROCKWELL COLLINS FRANCE
may cause, harmful interference and void the FCC authorization to operate this equipment




                                                            Page 7/32


                                                                                        RR051-17-100875-1-A Ed. 0




6.2 unintentional radiator (subpart B)


      Test                         Description of test                      Respected criteria?           Comment
   procedure                                                              Yes No NAp NAs

                                                                                                       See certification
FCC Part 15.105 INFORMATION TO THE USER                                    X
                                                                                                       documents

FCC Part 15.107 CONDUCTED LIMITS                                           X                           Class B

FCC Part 15.109 RADIATED EMISSION LIMITS                                   X                           Class B

FCC Part 15.111 ANTENNA POWER CONDUCTED LIMITS FOR
                                                                                            X
                RECEIVER

NAp: Not Applicable               NAs: Not Asked


   USER NOTICE SHALL CONTAIN

The user notice, not provided during tests, shall include the following informations:

§ 15.105:
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against
harmful interference in a residential installation. This equipment generates uses and can radiate radio
frequency energy and, if not installed and used in accordance with the instructions, may cause harmful
interference to radio communications. However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to radio or television reception, which
can be determined by turning the equipment off and on, the user is encouraged to try to correct the
interference's by one or more of the following measures:
-Reorient or relocate the receiving antenna.
-Increase the separation between the equipment and the receiver.
-Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
-Consult the dealer or an experienced radio/TV technician for help.




                                                    Page 8/32


                                                                               RR051-17-100875-1-A Ed. 0




6.3 intentional radiator (subpart C)


     Test                          Description of test                  Respected criteria?           Comment
  procedure                                                           Yes No NAp NAs

FCC Part 15.203 ANTENNA REQUIREMENT                                    X                          Note 1

FCC Part 15.205 RESTRICTED BANDS OF OPERATION                          X

FCC Part 15.207 CONDUCTED LIMITS                                       X

FCC Part 15.209 RADIATED EMISSION LIMITS; general                                                 Note 2
                                                                       X
                requirements

FCC part 15.215 ADDITIONAL PROVISIONS TO THE GENERAL
                RADIATED EMISSION LIMITATIONS
                (a) Alternative to general radiated emission limits    X
                (b) Unwanted emissions outside of §15.249                                         Note 3
                                                                       X
                frequency bands
                (c) 20 dB bandwidth and band-edge compliance           X

FCC Part 15.249 OPERATION WITHIN THE BANDS 902-928 MHZ,
                2400-2483.5 MHz, 5725-5850 MHz AND 24.0-
                24.25 GHz
                (a) Fundamental and harmonics field strength           X
                (b) Fixed point-to-point operation                                   X
                (c) Measurement distance                               X
                (d) Out-of-band emissions                              X
                (e) Field strength limits above 1 GHz                  X

NAp: Not Applicable             NAs: Not Asked


Note 1: dedicated antenna.

Note 2: See FCC part 15.249 (d).

Note 3: See FCC part 15.209. Unwanted emissions levels are all below the fundamental emission field
        strength level.




                                                 Page 9/32


                                                                                      RR051-17-100875-1-A Ed. 0




RF EXPOSURE:

Maximum measured power = 108.05 dBµV/m = 19.15mW at 5800 MHz
with P = (E×d)2 / (30×Gp) with d = 3 m and Gp = 1


In accordance with KDB 447498 D01 General RF Exposure Guidance v06:

PSD= EIRP/(4*π*R2)

       19.15/(4*π*(20 cm)²)= 0.00381 mW/cm² (limit = 1mW/cm²)

The equipment fulfils the requirements on power density for general population/uncontrolled exposure
and therefore fulfils the requirements of 47 CFR §1.1310.



7.    MEASUREMENT UNCERTAINTY

To declare, or not, the compliance with the specifications, it was not explicitly taken into account of uncertainty
associated with the result(s).

The reported expanded uncertainty of measurement is stated as the standard uncertainty of measurement
multiplied by the coverage factor k=2, which for normal distribution corresponds to a coverage probability of
approximately 95%.

                                                                          Emitech
                                      Parameter
                                                                         Uncertainty
                       RF power, conducted                                 0.75dB
                       Radiated emission valid to 26 GHz
                                                F < 62.5 MHz:              5.14 dB
                                      62.5 MHz < F < 1 GHz:                5.13 dB
                                       1 GHz < F < 26 GHz:                 5.16 dB
                       AC Power Lines conducted emissions                  3.38 dB
                       Temperature                                           1 °C
                       Humidity                                             5%




                                                    Page 10/32


                                                                               RR051-17-100875-1-A Ed. 0




8.    MEASUREMENT OF THE CONDUCTED DISTURBANCES

Standard: FCC Part 15

Test procedure: Paragraph 15.107

Limits: Class B

Software used: BAT-EMC V3.6.0.32

Test set up:

The EUT is isolated and placed on a wooden table, 0.8 m over an horizontal reference plane and 0.4 m from a
vertical reference plane. It is powered by an artificial main network placed on the ground reference plane.
The equipment is powered with the AC power operating voltage of 120 V / 60 Hz.

See photos in appendix 2

Frequency range: 150 kHz - 30 MHz

Detection mode: Peak / Quasi-peak / Average

Bandwidth: 10 kHz / 9 kHz

Equipment under test operating condition:

The equipment is blocked in Mute mode.




                                                Page 11/32


                                                                             RR051-17-100875-1-A Ed. 0




Results:

Ambient temperature (°C):                                 26.2
Relative humidity (%):                                     51

Power source: We used for power source the POE provided by the customer supplied with 120Vac / 60Hz.


Sample N° 1:

Measurement on the mains power supply:

The measurement is first realized with Peak detector.

Curve N° 1:          measurement on the Neutral with peak detector
                                                                                       FCC part 15 : 10 §107 - Classe:B - Moyenne/
                                                                                       FCC part 15 : 10 §107 - Classe:B - QCrête/
                                                                                       Mes.Peak (Neutre)
                                                                                       (Neutre)

       90
dBµV


       80




       70




       60




       50




       40




       30




       20




       10




       0
            150kHz                                                                                                        30MHz
                                                          Fréquence (MHz)                                           Ligne: Neutre




                                                    Page 12/32


                                                                                          RR051-17-100875-1-A Ed. 0




Curve N° 2:            measurement on the Line with peak detector
                                                                                                   FCC part 15 : 10 §107 - Classe:B - Moyenne/
                                                                                                   FCC part 15 : 10 §107 - Classe:B - QCrête/
                                                                                                   Mes.Peak (Phase 1)
                                                                                                   (Phase 1)

       90
dBµV


       80




       70




       60




       50




       40




       30




       20




       10




       0
            150kHz                                                                                                                     30MHz
                                                                Fréquence (MHz)                                                Ligne: Phase 1




The frequencies which are not 6 dB under the Average limit are then analyzed with Average detector and
Quasi-peak detector:

Table N° 1:            average measurement on the Neutral, for the frequency range:
                Frequency     Quasi-     QP Limit   QP margin             Frequency   Average   Average          Average
                  (MHz)        peak      (dBµV)       (dB)                  (MHz)     (dBµV)     Limit            margin
                              (dBµV)                                                            (dBµV)             (dB)
                0.508275        49.6     56.000       6.400               0.508275    38.09     46.000             7.910
                0.684905       40.73     56.000      15.270               0.684905    29.31     46.000            16.690
                0.726725       39.47     56.000      16.530               0.726725     27.5     46.000            18.500
                 1.0495       37.560     56.000      18.440                1.0495     29.37     46.000            16.630
                 1.1764       37.020     56.000      18.980                1.1764      24.7     46.000            21.300
                 1.8172       39.930     56.000      16.070                1.8172     26.96     46.000            19.040
                 1.8685        41.46     56.000      14.540                1.8685     29.57     46.000            16.430
                 1.9522        42.41     56.000      13.590                1.9522     31.55     46.000            14.450
                 2.0566        41.42     56.000      14.580                2.0566     30.33     46.000            15.670
                 2.2366        40.55     56.000      15.450                2.2366     27.32     46.000            18.680
                 2.3527        39.53     56.000      16.470                2.3527     29.62     46.000            16.380
                 4.6864        37.94     56.000      18.060                4.6864     31.72     46.000            14.280
                 5.3884         41.5     60.000      18.500                5.3884     35.12     50.000            14.880
                  5.608        43.91     60.000      16.090                 5.608     37.54     50.000            12.460
                 5.9905        41.83     60.000      18.170                5.9905     34.93     50.000            15.070
                 23.518        39.98     60.000      20.020                23.518     34.93     50.000            15.070
                 24.108        42.56     60.000      17.440                24.108     38.24     50.000            11.760

                                                       Page 13/32


                                                                              RR051-17-100875-1-A Ed. 0




Table N° 2:   average measurement on the Line, for the frequency range:
       Frequency     Quasi-    QP Limit   QP margin        Frequency      Average   Average   Average
         (MHz)        peak     (dBµV)       (dB)             (MHz)        (dBµV)     Limit     margin
                     (dBµV)                                                         (dBµV)      (dB)
         0.50632     48.69      56.000      7.310           0.50632       37.03     46.000     8.970
         0.54117     45.02      56.000     10.980           0.54117       32.42     46.000    13.580
         0.68329     40.62      56.000     15.380           0.68329       28.88     46.000    17.120
        0.724855      39        56.000     17.000          0.724855       26.43     46.000    19.570
          1.036      36.88      56.000     19.120            1.036        22.74     46.000    23.260
         1.1008      38.35      56.000     17.650           1.1008        25.84     46.000    20.160
         1.1341      37.82      56.000     18.180           1.1341        25.65     46.000    20.350
         1.8136      39.72      56.000     16.280           1.8136        27.15     46.000    18.850
         1.8685      41.69      56.000     14.310           1.8685        29.62     46.000    16.380
         2.0008      42.95      56.000     13.050           2.0008        31.78     46.000    14.220
         2.0845      39.83      56.000     16.170           2.0845        28.52     46.000    17.480
         2.2645      41.19      56.000     14.810           2.2645        28.62     46.000    17.380
         5.0347      38.62      60.000     21.380           5.0347         32.5     50.000    17.500
         5.7115      42.15      60.000     17.850           5.7115        35.42     50.000    14.580
          24.11      42.44      60.000     17.560            24.11         38.4     50.000    11.600


Test conclusion:

RESPECTED STANDARD




                                              Page 14/32


                                                                                     RR051-17-100875-1-A Ed. 0




9.    RADIATED EMISSION LIMITS

Standard: FCC Part 15

Test procedure: Paragraph 109

Limit class: Class B

Test set up:

The final measurement is realized with the product placed in his normal orientation.

The measure is realized on open area test site under 1 GHz and in anechoic chamber above 1 GHz.

When the system is tested in an open area test site (OATS), the EUT is placed on a rotating table, 0.8m from
a ground plane.

When the system is tested in anechoic chamber, the EUT is placed on a rotating table, 1.65m from a ground
plane.

Zero degree azimuths correspond to the front of the device under test.

See photos in appendix 2.

Frequency range: From 30 MHz to 40 GHZ.

Detection mode: Quasi-peak (F < 1 GHz)                     Average (F > 1 GHz)

Bandwidth: 120 kHz (F < 1 GHz)                             1 MHz (F > 1 GHz)

Distance of antenna: 10 meters (in open area test site) / 3 meters (in anechoic room)

Antenna height: 1 to 4 meters (in open area test site) / 1.65 meter (in anechoic room)

Antenna polarization: vertical and horizontal (only the highest level is recorded)

Equipment under test operating condition:

The equipment is blocked in mute mode.




                                                  Page 15/32


                                                                                        RR051-17-100875-1-A Ed. 0




    Results:

    Ambient temperature (°C):                                 23.7
    Relative humidity (%):                                     38

    Power source: We used for power source the POE provided by the customer supplied with 120Vac / 60Hz.


    Sample N° 1: Low, Central and High Channel

Frequencies Detector Antenna Azimuth RBW Polarization                       Field    Field         Limits     Margin
   (MHz)       P      height (degree) (kHz) H: Horizontal                 strength strength      (dBV/m)      (dB)
              QP       (cm)                 V: Vertical                  Measured Computed           or
              Av                                                          at 10 m   at 3 m         (dBm)
                                                                         (dBV/m) (dBV/m)
   70.53        QP        400          92      120            V            14.07    24.47            40        15.53
   83.36        QP        100          0       120            V            29.26    39.66            40        0.34
    110         QP        100         102      120            V            27.63    38.03           43.5       5.47
  159.27        QP        100         343      120            V            28.85    39.25           43.5       4.25
  218.06        QP        381          0       120            H            32.94    43.34            46        2.66
    500         QP        274         117      120            H            28.48    38.88            46        7.12
   2500          P         —           —       1000           V              —     43.6 (1)          74        30.4
         P= Peak, QP=Quasi-peak, Av=Average
         (1) The peak level is lower than the average limit


    Applicable limits: for 30 MHz ≤ F ≤ 88 MHz :                  40 dBµV/m at 3 meters
                       for 88 MHz < F ≤ 216 MHz :                 43.5 dBµV/m at 3 meters
                       for 216 MHz < F ≤ 960 MHz :                46 dBµV/m at 3 meters
                       Above 960 MHz :                            54 dBµV/m at 3 meters


    Test conclusion:

    RESPECTED STANDARD




                                                       Page 16/32


                                                                               RR051-17-100875-1-A Ed. 0




10.   MEASUREMENT OF THE CONDUCTED DISTURBANCES

Standard: FCC Part 15

Test procedure: Paragraph 15.207

Software used: BAT-EMC V3.6.0.32

Test set up:

The EUT is isolated and placed on a wooden table, 0.8 m over an horizontal reference plane and 0.4 m from a
vertical reference plane. It is powered by an artificial main network placed on the ground reference plane.
The equipment is powered with the AC power operating voltage of 120 V / 60 Hz.

See photos in appendix 2

Frequency range: 150 kHz - 30 MHz

Detection mode: Peak / Quasi-peak / Average

Bandwidth: 10 kHz / 9 kHz

Equipment under test operating condition:

The equipment under test is blocked in continuous modulated transmission mode, at the highest output power
level at which the transmitter is intended to operate.




                                                Page 17/32


                                                                             RR051-17-100875-1-A Ed. 0




Results:

Ambient temperature (°C):                                 26.2
Relative humidity (%):                                     51

Power source: We used for power source the POE provided by the customer supplied with 120Vac / 60Hz.


Sample N° 1:

Measurement on the mains power supply:

The measurement is first realized with Peak detector.

Curve N° 3:          measurement on the Neutral with peak detector
                                                                                       FCC part 15 : 10 §107 - Classe:B - Moyenne/
                                                                                       FCC part 15 : 10 §107 - Classe:B - QCrête/
                                                                                       Mes.Peak (Neutre)
                                                                                       Suspect CISPR25 3ème (Neutre)

       90
dBµV


       80




       70




       60




       50




       40




       30




       20




       10




       0
            150kHz                                                                                                        30MHz
                                                          Fréquence (MHz)                                           Ligne: Neutre




                                                    Page 18/32


                                                                                          RR051-17-100875-1-A Ed. 0




Curve N° 4:            measurement on the Line with peak detector
                                                                                                   FCC part 15 : 10 §107 - Classe:B - Moyenne/
                                                                                                   FCC part 15 : 10 §107 - Classe:B - QCrête/
                                                                                                   Mes.Peak (Phase 1)
                                                                                                   Suspect CISPR25 3ème (Phase 1)

       90
dBµV


       80




       70




       60




       50




       40




       30




       20




       10




       0
            150kHz                                                                                                                     30MHz
                                                                Fréquence (MHz)                                                Ligne: Phase 1




The frequencies which are not 6 dB under the Average limit are then analyzed with Average detector and
Quasi-peak detector:

Table N° 3:            average measurement on the Neutral, for the frequency range:
                Frequency     Quasi-     QP Limit   QP margin             Frequency   Average   Average          Average
                  (MHz)        peak      (dBµV)       (dB)                  (MHz)     (dBµV)     Limit            margin
                              (dBµV)                                                            (dBµV)             (dB)
                 0.46569      39.62      56.590      16.970                0.46569     28.5     46.590            18.090
                0.508105      49.66      56.000       6.340               0.508105    37.62     46.000             8.380
                0.538705      45.19      56.000      10.810               0.538705    31.87     46.000            14.130
                0.685755      40.99      56.000      15.010               0.685755    28.88     46.000            17.120
                 0.72613      39.58      56.000      16.420                0.72613    27.14     46.000            18.860
                 1.0927       37.94      56.000      18.060                1.0927     25.45     46.000            20.550
                 1.9045       41.78      56.000      14.220                1.9045     30.43     46.000            15.570
                  2.008       42.49      56.000      13.510                 2.008     30.98     46.000            15.020
                 2.2375       40.29      56.000      15.710                2.2375     26.86     46.000            19.140
                 4.6045       38.71      56.000      17.290                4.6045     31.38     46.000            14.620
                 5.5585       43.28      60.000      16.720                5.5585     36.63     50.000            13.370
                 6.0841       41.81      60.000      18.190                6.0841      34.3     50.000            15.700
                 24.102       42.77      60.000      17.230                24.102     38.29     50.000            11.710




                                                       Page 19/32


                                                                              RR051-17-100875-1-A Ed. 0




Table N° 4:   average measurement on the Line, for the frequency range:
       Frequency     Quasi-    QP Limit   QP margin        Frequency      Average   Average   Average
         (MHz)        peak     (dBµV)       (dB)             (MHz)        (dBµV)     Limit     margin
                     (dBµV)                                                         (dBµV)      (dB)
         0.46654     37.07      56.575     19.505           0.46654       25.51     46.575    21.065
        0.508785     48.76      56.000      7.240          0.508785       35.59     46.000    10.410
        0.546355     44.43      56.000     11.570          0.546355       32.33     46.000    13.670
        0.685415      40.9      56.000     15.100          0.685415       28.39     46.000    17.610
          1.054      38.09      56.000     17.910            1.054         25.8     46.000    20.200
         1.8622      41.58      56.000     14.420           1.8622        29.49     46.000    16.510
         1.9612      42.41      56.000     13.590           1.9612        31.35     46.000    14.650
         2.2897      41.28      56.000     14.720           2.2897        29.86     46.000    16.140
         5.0176       38.5      60.000     21.500           5.0176        31.74     50.000    18.260
         5.6845      42.41      60.000     17.590           5.6845        35.13     50.000    14.870
         24.102      41.87      60.000     18.130           24.102        35.59     50.000    14.410


Test conclusion:

RESPECTED STANDARD




                                              Page 20/32


                                                                                RR051-17-100875-1-A Ed. 0




  11.   ADDITIONAL PROVISIONS TO THE GENERAL RADIATED EMISSION LIMITATIONS

  Standard: FCC Part 15

  Test procedure: Paragraph 15.215

  Test set up:

  Test realized in near field. All field strength measurements are correlated with the radiated maximum peak
  output power

  Test operating condition of the equipment:

  The equipment under test is blocked in continuous transmission mode, modulated by internal data signal, at
  the highest output power level which the transmitter is intended to operate.


  Results:

  Ambient temperature (°C):                              21.3
  Relative humidity (%):                                  46

  Power source: We used for power source the POE provided by the customer supplied with 120Vac / 60Hz.

  Lower Band Edge: band from 5723 MHz to 5725 MHz
  Upper Band Edge: band from 5875 MHz to 5877 MHz


  Sample N° 1:

   Low Channel:
Fundamental     Field Strength   Detector      Frequency  Delta         Calculated      Limit         Margin
frequency       Level of         (Peak or      of maximum Marker        Max Out-of-     (dBµV/m)      (dB)
(MHz)           fundamental      Average)      Band-edges (dB) (1)      Band
                (dBµV/m)                       Emission                 Emission
                                               (MHz)                    Level
                                                                        (dBµV/m)
5750             107.75          Peak          5724.92          36.45   71.3            74            2.7
5750             107.75          Av            5724.92          67.61   40.14           54            13.86
5850             107.64          Peak          5875.07          36.50   71.14           74            2.86
5850             107.64          Av            5875.07          68.71   38.93           54            15.07

  (1) Marker-Delta method

  Band-edge curves are given in appendix 4.


  Test conclusion:

  RESPECTED STANDARD


                                                  Page 21/32


                                                                                     RR051-17-100875-1-A Ed. 0




12.   FUNDAMENTAL AND HARMONICS FIELD STRENGTH

Standard: FCC Part 15

Test procedure: paragraph 15.249 (a)

Test set up:

The final measurement is realized with the product placed in his normal orientation.

The system is tested in anechoic chamber, the EUT is placed on a rotating table, 1.65m from a ground plane.

Zero degree azimuths correspond to the front of the device under test.

See photos in appendix 2.

Frequency range: From 1 GHz to 40 GHz.

Detection mode:      Peak / Average (F > 1 GHz)

Bandwidth:     1 MHz (F > 1 GHz)

Distance of antenna: 3 meters (in anechoic room)

Antenna height: 1.65 meter (in anechoic room)

Antenna polarization: vertical and horizontal (only the highest level is recorded)

Equipment under test operating condition:

The equipment under test is blocked in continuous transmission mode, modulated by internal data signal, at
the highest output power level which the transmitter is intended to operate.




                                                  Page 22/32


                                                                               RR051-17-100875-1-A Ed. 0




Results:

Ambient temperature (°C):                            21.3
Relative humidity (%):                                46

Power source: We used for power source the POE provided by the customer supplied with 120Vac / 60Hz.


Sample N° 1       Low Channel

 Frequencies Detector Antenna Azimuth RBW          Polarization       Field          Limits     Margin
    (MHz)       P      height (degree) (kHz)       H: Horizontal    strength       (dBV/m)      (dB)
               QP       (cm)                       V: Vertical     Measured            or
               Av                                                    at 3 m          (dBm)
                                                                   (dBV/m)
     5750*       P        165    355        1000            V        107.75          114         6.25
    P= Peak, QP=Quasi-peak, Av=Average
    *Fundamental emission


Sample N° 1       Central Channel

 Frequencies Detector Antenna Azimuth RBW          Polarization       Field          Limits     Margin
    (MHz)       P      height (degree) (kHz)       H: Horizontal    strength       (dBV/m)      (dB)
               QP       (cm)                       V: Vertical     Measured            or
               Av                                                    at 3 m          (dBm)
                                                                   (dBV/m)
     5800*       P        165    355        1000            V        108.05          114         5.95
    P= Peak, QP=Quasi-peak, Av=Average
    *Fundamental emission


Sample N° 1       High Channel

 Frequencies Detector Antenna Azimuth RBW          Polarization       Field          Limits     Margin
    (MHz)       P      height (degree) (kHz)       H: Horizontal    strength       (dBV/m)      (dB)
               QP       (cm)                       V: Vertical     Measured            or
               Av                                                    at 3 m          (dBm)
                                                                   (dBV/m)
     5850*       P        165    353        1000            V        107.64          114         6.36
    P= Peak, QP=Quasi-peak, Av=Average
    *Fundamental emission


Applicable limits: table 15.249 a)


Test conclusion:

RESPECTED STANDARD


                                              Page 23/32


                                                                                     RR051-17-100875-1-A Ed. 0




13.   OUT-OF-BAND EMISSIONS

Standard: FCC Part 15

Test procedure: paragraph 15.205
                paragraph 15.209
                paragraph 15.249 (d)

Test set up:

The final measurement is realized with the product placed in his normal orientation.

The measure is realized on open area test site under 1 GHz and in anechoic chamber above 1 GHz.

When the system is tested in an open area test site (OATS), the EUT is placed on a rotating table, 0.8m from
a ground plane.

When the system is tested in anechoic chamber, the EUT is placed on a rotating table, 1.65m from a ground
plane.

Zero degree azimuths correspond to the front of the device under test.

See photos in appendix 2.

Frequency range: From 9 kHz to 40 GHz.

Detection mode: Quasi-peak (F < 1 GHz)                     Peak / Average (F > 1 GHz)

Bandwidth:     200Hz (9 kHz < F < 150kHz)
               9 kHz (150 kHz < F < 30MHz)
               120 kHz (30 MHz < F < 1 GHz)
               1 MHz (F > 1 GHz)

Distance of antenna: 10 meters (in open area test site) / 3 meters (in anechoic room)

Antenna height: 1 to 4 meters (in open area test site) / 1.65 meter (in anechoic room)

Antenna polarization: vertical and horizontal (only the highest level is recorded)

Equipment under test operating condition:

The equipment under test is blocked in continuous transmission mode, modulated by internal data signal, at
the highest output power level which the transmitter is intended to operate.




                                                  Page 24/32


                                                                                       RR051-17-100875-1-A Ed. 0




    Results:

    Ambient temperature (°C):                                 27.5
    Relative humidity (%):                                     44

    Power source: We used for power source the POE provided by the customer supplied with 120Vac / 60Hz.


    Sample N° 1: Low, Central and High Channel

Frequencies Detector Antenna Azimuth RBW Polarization                      Field    Field         Limits     Margin
   (MHz)       P      height (degree) (kHz) H: Horizontal                strength strength      (dBV/m)      (dB)
              QP       (cm)                 V: Vertical                 Measured Computed           or
              Av                                                         at 10 m   at 3 m         (dBm)
                                                                        (dBV/m) (dBV/m)
   70.53        QP        400          92      120            V           14.07    24.47            40        15.53
   83.36        QP        100          0       120            V           29.26    39.66            40        0.34
    110         QP        100         102      120            V           27.63    38.03           43.5       5.47
  159.27        QP        100         343      120            V           28.85    39.25           43.5       4.25
  218.06        QP        381          0       120            H           32.94    43.34            46        2.66
    500         QP        274         117      120            H           28.48    38.88            46        7.12
   2500          P         —           —       1000           V             —     43.6 (1)          74        30.4
         P= Peak, QP=Quasi-peak, Av=Average
         (1) The peak level is lower than the average limit


    Applicable limits:    for 9 kHz ≤ F ≤ 490 kHz :               2400/F(kHz) at 300 meters
                          for 490 kHz < F ≤ 1.705 MHz :           24000/F(kHz) at 30 meters
                          for 1.705 MHz < F ≤ 30 MHz :            29.5 dBµV/m at 30 meters
                          for 30 MHz < F ≤ 88 MHz :               40 dBµV/m at 3 meters
                          for 88 MHz < F ≤ 216 MHz :              43.5 dBµV/m at 3 meters
                          for 216 MHz < F ≤ 960 MHz :             46 dBµV/m at 3 meters
                          Above 960 MHz :                         54 dBµV/m at 3 meters


    Test conclusion:

    RESPECTED STANDARD

                             End of report, 4 appendixes to be forwarded 




                                                       Page 25/32


                                          RR051-17-100875-1-A Ed. 0




APPENDIX 1: Photos of the equipment under test




                CONFIDENTIAL




                  Page 26/32


                          RR051-17-100875-1-A Ed. 0




APPENDIX 2: Test set up




     CONFIDENTIAL




       Page 27/32


                                                                           RR051-17-100875-1-A Ed. 0




                               APPENDIX 3: Test equipment list

                           Measurement of the conducted disturbances

                    TYPE                           MANUFACTURER               EMITECH NUMBER
Outside room Hors cage                      Emitech                                10788
Satellite synchronized frequency standard   ACQUISYS                                8896
GPS8
Test receiver ESU8                          Rohde & Schwarz                          9403
LISN 1600                                   Thurbly Thandar Instruments              8719
LISN ESH3-Z5                                Rohde & Schwarz                          8720
High-pass filter EZ-25                      Rohde & Schwarz                          8635
Absorber sheath current                     Emitech                                  9489
Power source 1251RP                         California instruments                   8508
Multimeter IDM106N                          ISOTECH                                  8676
Meteo station WS-9232                       La Crosse Technology                     8750


                          Radiated emission limits; general requirements

                    TYPE                         MANUFACTURER                 EMITECH NUMBER
Full Anechoic Chamber                       EMITECH                                10759
Satellite synchronized frequency standard   ACQUISYS                                8896
GPS8
Spectrum Analyzer FSP40                     Rohde & Schwarz                           4088
Biconical antenna 3110                      EMCO                                      7240
Log periodic antenna HL223                  Rohde & Schwarz                           7190
Antenna 3117                                EMCO                                     10771
Low-noise amplifier ZFL-1000LN              Mini Circuit                             10730
Low-noise amplifier S005180M3201            LUCIX Corp                               10739
Low-noise amplifier C020180F-4B1            Microwave DB                              1922
Low-noise amplifier S180265L3201            LUCIX Corp.                               8704
Low-noise amplifier ALS2640-30-10           ALC                                       4354
Attenuator 10dB                             Pasternack                                9266
Low pass filter LP03/1000-7GH               Filtek                                    4087
Low Pass Filter LPM15601                    Microtronics                              6606
High Pass Filter LPM15600                   Microtronics                              6607
Power source 1251RP                         California instruments                    8508
Multimeter IDM106N                          ISOTECH                                   8676
Meteo station 608-Hi                        Testo                                     7566
Software                                    BAT-EMC V3.6.0.32                         0000




                                            Page 28/32


                                                                          RR051-17-100875-1-A Ed. 0




                Additional provisions to the general radiated emission limitations

                    TYPE                         MANUFACTURER                 EMITECH NUMBER
Full Anechoic Chamber                       EMITECH                                10759
Satellite synchronized frequency standard   ACQUISYS                                8896
GPS8
Spectrum Analyzer FSP40                     Rohde & Schwarz                           4088
Antenna 3117                                EMCO                                     10771
Power source 1251RP                         California instruments                    8508
Multimeter IDM106N                          ISOTECH                                   8676
Meteo station 608-Hi                        Testo                                     7566
Software                                    GPIBShot V2.4                               -


                            Fundamental and harmonics field strength

                    TYPE                         MANUFACTURER                 EMITECH NUMBER
Full Anechoic Chamber                       EMITECH                                10759
Satellite synchronized frequency standard   ACQUISYS                                8896
GPS8
Spectrum Analyzer FSP40                     Rohde & Schwarz                           4088
Antenna 3117                                EMCO                                     10771
Low-noise amplifier S005180M3201            LUCIX Corp                               10739
Low-noise amplifier C020180F-4B1            Microwave DB                              1922
Low-noise amplifier S180265L3201            LUCIX Corp.                               8704
Low-noise amplifier ALS2640-30-10           ALC                                       4354
Attenuator 10dB                             Pasternack                                9266
Low Pass Filter LPM15601                    Microtronics                              6606
High Pass Filter LPM15600                   Microtronics                              6607
Power source 1251RP                         California instruments                    8508
Multimeter IDM106N                          ISOTECH                                   8676
Meteo station 608-Hi                        Testo                                     7566
Software                                    BAT-EMC V3.6.0.32                         0000




                                            Page 29/32


                                                                     RR051-17-100875-1-A Ed. 0




                                       Out-of-band emissions

                    TYPE                         MANUFACTURER           EMITECH NUMBER
Full Anechoic Chamber                       EMITECH                          10759
Satellite synchronized frequency standard   ACQUISYS                          8896
GPS8
Spectrum Analyzer FSP40                     Rohde & Schwarz                     4088
Loop antenna 6502                           EMCO                                1406
Biconical antenna 3110                      EMCO                                7240
Log periodic antenna HL223                  Rohde & Schwarz                     7190
Antenna 3117                                EMCO                               10771
Low-noise amplifier ZFL-1000LN              Mini Circuit                       10730
Low-noise amplifier S005180M3201            LUCIX Corp                         10739
Low-noise amplifier C020180F-4B1            Microwave DB                        1922
Low-noise amplifier S180265L3201            LUCIX Corp.                         8704
Low-noise amplifier ALS2640-30-10           ALC                                 4354
Attenuator 10dB                             Pasternack                          9266
Low pass filter LP03/1000-7GH               Filtek                              4087
Low Pass Filter LPM15601                    Microtronics                        6606
High Pass Filter LPM15600                   Microtronics                        6607
Power source 1251RP                         California instruments              8508
Multimeter IDM106N                          ISOTECH                             8676
Meteo station 608-Hi                        Testo                               7566
Software                                    BAT-EMC V3.6.0.32                   0000




                                            Page 30/32


                                           RR051-17-100875-1-A Ed. 0




      APPENDIX 4: Band Edge

Lower Band Edge – Worst case measurement




               Page 31/32


                                           RR051-17-100875-1-A Ed. 0




Upper Band Edge – Worst case measurement




               Page 32/32



Document Created: 2018-01-23 12:34:40
Document Modified: 2018-01-23 12:34:40

© 2025 FCC.report
This site is not affiliated with or endorsed by the FCC