DSS Test Report

FCC ID: AFJ375000

Test Report

Download: PDF
FCCID_3638956

RF TEST
REPORT

Report No.: FCC IC_RF_SL17090601-SEV-051
Supersede Report No.: None

FCC Applicant                         :   Icom Incorprated
IC Applicant                              Icom Canada Inc
Product Name                          :   Battery charger
Model No.                             :   375000-01 (BC-218)
                                          47 CFR 15.247
Test Standard                         :
                                          RSS 247 Iss 2: Feb 2017
                                          ANSI C63.10: 2013
Test Method                           :   RSS Gen Iss 4: Nov 2014
                                          558074 D01 DTS Meas Guidance v04
FCC ID                                   : AFJ375000
IC ID                                    : 202D‐375000
Dates of test                           : 10/14/2017
Issue Date                              : 10/20/2017
Test Result                             : ☒ Pass       ☐ Fail
Equipment complied with the specification       [X]
Equipment did not comply with the specification [ ]




This Test Report is Issued Under the Authority of:




                    Anish Kumar                                                  Gary Chou
                    Test Engineer                                            Engineer Reviewer

                                                    Issued By:
                                               SIEMIC Laboratories
                                    775 Montague Expressway, Milpitas, 95035 CA




        775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                            Visit us at: www.siemic.com; Follow us at:


                                                             Test report No.    FCC IC_RF_SL17090601-SEV-051
                                                             Page               2 of 24




                                         Laboratory Introduction
SIEMIC, headquartered in the heart of Silicon Valley, with superior facilities in US and Asia, is one of the leading independent testing
and certification facilities providing customers with one-stop shop services for Compliance Testing and Global Certifications.




In addition to testing and certification, SIEMIC provides initial design reviews and compliance management throughout a project. Our
extensive experience with China, Asia Pacific, North America, European, and International compliance requirements, assures the
fastest, most cost effective way to attain regulatory compliance for the global markets.

                                   Accreditations for Conformity Assessment
           Country/Region                  Accreditation Body                                     Scope
                 USA                            FCC, A2LA                              EMC, RF/Wireless, Telecom
              Canada                         IC, A2LA, NIST                            EMC, RF/Wireless, Telecom
               Taiwan                       BSMI, NCC, NIST                             EMC, RF, Telecom, Safety
             Hong Kong                         OFTA, NIST                                  RF/Wireless, Telecom
              Australia                        NATA, NIST                               EMC, RF, Telecom, Safety
               Korea                         KCC/RRA, NIST                           EMI, EMS, RF, Telecom, Safety
               Japan                     VCCI, JATE, TELEC, RFT                         EMI, RF/Wireless, Telecom
               Mexico                    NOM, COFETEL, Caniety                      Safety, EMC, RF/Wireless, Telecom
              Europe                           A2LA, NIST                               EMC, RF, Telecom, Safety
                Israel                          MOC, NIST                               EMC, RF, Telecom, Safety


                                    Accreditations for Product Certifications
              Country                       Accreditation Body                                   Scope
                USA                          FCC TCB, NIST                                  EMC, RF, Telecom
              Canada                          IC FCB, NIST                                  EMC, RF, Telecom
             Singapore                          iDA, NIST                                   EMC, RF, Telecom
                EU                                  NB                                    EMC & R&TTE Directive
               Japan                          MIC (RCB 208)                                   RF, Telecom
             Hong Kong                        OFTA (US002)                                    RF, Telecom




          775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                                Visit us at: www.siemic.com; Follow us at:


                                                                                  Test report No.           FCC IC_RF_SL17090601-SEV-051
                                                                                  Page                      3 of 24



CONTENTS
1      REPORT REVISION HISTORY........................................................................................................................................... 4
2      EXECUTIVE SUMMARY .................................................................................................................................................... 5
3      CUSTOMER INFORMATION ............................................................................................................................................. 5
4      TEST SITE INFORMATION ................................................................................................................................................ 5
5      MODIFICATION................................................................................................................................................................. 5
6      EUT INFORMATION .......................................................................................................................................................... 6
     6.1     EUT Description .......................................................................................................................................................... 6
     6.2     Radio Description ........................................................................................................................................................ 6
     6.3     EUT Photos | External.................................................................................................................................................. 7
     6.4     EUT Photos | Internal ................................................................................................................................................... 8
     6.5     EUT Test Setup Photos ............................................................................................................................................... 9
7      SUPPORTING EQUIPMENT/SOFTWARE AND CABLING DESCRIPTION ........................................................................ 10
     7.1     Supporting Equipment ............................................................................................................................................... 10
     7.2     Cabling Description.................................................................................................................................................... 10
     7.3     Test Software Description .......................................................................................................................................... 10
8      TEST SUMMARY ............................................................................................................................................................ 11
9      MEASUREMENT UNCERTAINTY .................................................................................................................................... 12
     9.1     Radiated Emissions (30MHz to 1GHz) ........................................................................................................................ 12
     9.2     Radiated Emissions (1GHz to 40GHz) ........................................................................................................................ 12
     9.3     RF conducted measurement ...................................................................................................................................... 13
10           MEASUREMENTS, EXAMINATION AND DERIVED RESULTS................................................................................... 14
     10.1        Radiated Spurious Emissions in restricted band...................................................................................................... 14
     10.2        Radiated Spurious Emissions below 1GHz ............................................................................................................. 16
     10.3        Radiated Spurious Emissions between 1GHz – 26.5GHz ........................................................................................ 19
ANNEX A. TEST INSTRUMENT .............................................................................................................................................. 22
ANNEX B. SIEMIC ACCREDITATION ...................................................................................................................................... 23




            775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                                           Visit us at: www.siemic.com; Follow us at:


                                                     Test report No.   FCC IC_RF_SL17090601-SEV-051
                                                     Page              4 of 24




1   Report Revision History
                                                  Report
                Report No.                                                  Description                 Issue Date
                                                  Version
     FCC IC_RF_SL17090601-SEV-051                  None                          Original               10/20/2017




      775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                          Visit us at: www.siemic.com; Follow us at:


                                                        Test report No.   FCC IC_RF_SL17090601-SEV-051
                                                        Page              5 of 24




2    Executive Summary

The purpose of this test program was to demonstrate compliance of following product
 Company:        Icom
 Product:        Battery Charger
 Model:          375000-01 (BC-218)

against the current Stipulated Standards. The specified model product stated above has demonstrated compliance with
the Stipulated Standard listed on 1st page.


3    Customer information
FCC
Applicant Name                  :   Icom Incorprated
Applicant Address               :   1-1-32 Kamiminami Hirano-ku, Osaka Japan 547-0003 Japan
Manufacturer Name               :   Icom Incorprated
Manufacturer Address            :   1-1-32 Kamiminami Hirano-ku, Osaka Japan 547-0003 Japan
IC
Applicant Name                  :   Icom Canada Inc
Applicant Address               :   Delta, BC, V4K5B8 150–6165 Hwy 17A
Manufacturer Name               :   Icom Canada Inc
Manufacturer Address            :   Delta, BC, V4K5B8 150–6165 Hwy 17A

4    Test site information

 Lab performing tests                    SIEMIC Laboratories
 Lab Address                             775 Montague Expressway, Milpitas, CA 95035
 FCC Test Site No.                       881796
 IC Test Site No.                        4842D-2
 VCCI Test Site No.                      A0133


5    Modification
                 Index                           Item                          Description                    Note
                    -                              -                                -                           -




         775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                             Visit us at: www.siemic.com; Follow us at:


                                                        Test report No.      FCC IC_RF_SL17090601-SEV-051
                                                        Page                 6 of 24


6      EUT Information
 6.1     EUT Description


Product Name                     Battery Charger
Model No.                        BC-218
Trade Name                       Icom
Serial No.                       01001380
Host Model No.                   N/A
Input Power                      12 Vdc
Power Adapter Manu/Model         I.T.E / SA142D-12U
Date of EUT received             10/02/2017
Equipment Class/ Category        DTS
Clock Frequencies                N/A
Port/Connectors                  MicroUSB

 6.2     Radio Description

Bluetooth :

             Radio Type                                                      Bluetooth (Ver4.1)
        Operating Frequency                                                    2402MHz-2480MHz
             Modulation                                                    GFSK, π/4 DPSK, 8DPSK
          Channel Spacing                                                             1 MHz
            Antenna Type                                                  Multilayer Monopole Antenna
            Antenna Gain                                                             2.7 dBi
       Antenna Connector Type                                                          N/A
                 Note                                                                  N/A




         775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                             Visit us at: www.siemic.com; Follow us at:


                                                   Test report No.   FCC IC_RF_SL17090601-SEV-051
                                                   Page              7 of 24


6.3 EUT Photos | External




                 EUT – View 1                                                     EUT – View 2




                 EUT – View 3                                                   Adaptor – View 1




               Adaptor – View 2




    775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                        Visit us at: www.siemic.com; Follow us at:


                                                     Test report No.   FCC IC_RF_SL17090601-SEV-051
                                                     Page              8 of 24




6.4   EUT Photos | Internal




               Main Board - Top View                                             Main Board - Bottom View




      775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                          Visit us at: www.siemic.com; Follow us at:


                                                        Test report No.   FCC IC_RF_SL17090601-SEV-051
                                                        Page              9 of 24




6.5     EUT Test Setup Photos




      Radiated Emissions 30-1000MHz - Front View                 Radiated Emissions 30-1000MHz- Rear View




      Radiated Emissions Above 1GHz - Front View                 Radiated Emissions Above 1GHz - Rear View




         775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                             Visit us at: www.siemic.com; Follow us at:


                                                           Test report No.      FCC IC_RF_SL17090601-SEV-051
                                                           Page                 10 of 24




7     Supporting Equipment/Software and cabling Description
7.1        Supporting Equipment

              Supporting Equipment
    Item                                         Model                       Serial Number              Manufacturer         Note
                  Description
     1               Laptop                    HP Stream                          N/A                        HP               -
     2               Fixture                      N/A                             N/A                        N/A              -

7.2        Cabling Description

                             Connection Start                   Connection Stop                   Length / shielding Info
           Name                                                                                                               Note
                           From          I/O Port             To            I/O Port             Length (m)      Shielding
           USB             EUT             USB              Fixture          Laptop                  1             YES            -




7.3        Test Software Description

      Test Item                       Software                                                   Description
      RF Testing                    BLUE TEST 3                                            Control Bluetooth Module




           775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                               Visit us at: www.siemic.com; Follow us at:


                                                                   Test report No.      FCC IC_RF_SL17090601-SEV-051
                                                                   Page                 11 of 24


8       Test Summary

            Test Item                        Test standard                             Test Method/Procedure                           Pass / Fail
                                      FCC           15.205             FCC                     ANSI C63.10:2013                       ☐ Pass
Restricted Band of Operation                                                           558074 D01 DTS Meas Guidance v04
                                       IC        RSS Gen 8.10           IC                                                            ☒ N/A
                                      FCC          15.207(a)           FCC                    ANSI C63.10:2013                        ☐ Pass
    AC Conducted Emissions
                                       IC        RSS Gen 8.8            IC                  RSS Gen Issue 4: 2014                     ☒ N/A

DTS Band Requirement
             Test Item                       Test standard                               Test Method/Procedure                          Pass / Fail

                                        -               -                -                             -                              ☐ Pass
     99% Occupied Bandwidth
                                       IC          RSS Gen 6.6          IC                  RSS Gen Issue 4: 2014 -                   ☒ N/A
                                      FCC          15.247(a)(2)        FCC                                                            ☐ Pass
          6dB Bandwidth                                                               558074 D01 DTS Meas Guidance v04
                                       IC         RSS247 (5.2.1)          IC                                                          ☒ N/A

     Band Edge and Radiated           FCC           15.247(d)          FCC                    ANSI C63.10:2013                        ☒ Pass
       Spurious Emissions                                                             558074 D01 DTS Meas Guidance v04                ☐ N/A
                                       IC          RSS247 (5.5)           IC
                                      FCC           15.247(b)          FCC                                                            ☐ Pass
           Output Power                                                               558074 D01 DTS Meas Guidance v04
                                       IC         RSS247 (5.4.4)          IC                                                          ☒ N/A
                                                                                                                                      ☐ Pass
 Receiver Spurious Emissions           IC         RSS Gen (4.8)           IC                 RSS Gen Issue 4: 2014
                                                                                                                                      ☒ N/A
                                      FCC           15.247(e)          FCC                               -                            ☐ Pass
       Antenna Gain > 6 dBi
                                       IC                -                IC                             -                            ☒ N/A
                                      FCC           15.247(e)          FCC                                                            ☐ Pass
      Power Spectral Density                                                           558074 D01 DTS Meas Guidance v04
                                     IC         RSS247 (5.2.2)            IC                                                          ☒ N/A
                                    FCC             15.247(i)           FCC                             -                             ☐ Pass
     RF Exposure requirement
                                     IC          RSS Gen(5.5)             IC                 RSS Gen Issue 4: 2014                    ☒ N/A
                    1. All measurement uncertainties do not take into consideration for all presented test results.
    Remark          2. The applicant shall ensure frequency stability by showing that an emission is maintained within the band of operation under
                         all normal operating conditions as specified in the user’s manual.




            775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                                    Visit us at: www.siemic.com; Follow us at:


                                                             Test report No.    FCC IC_RF_SL17090601-SEV-051
                                                             Page               12 of 24




9      Measurement Uncertainty
 9.1     Radiated Emissions (30MHz to 1GHz)

         The test is to measure the radiated emissions of the EUT.

         Some error sources that can contribute to the total uncertainty:
         -   Uncertainty of the receiver
         -   Uncertainty of the antenna
         -   Uncertainty of cables
         -   Uncertainty due to the mismatches
         -   NSA Calibration
         -   Etc., details see the below table

                                              Value          Probability                    Sensitivity      Expanded
                Source of Uncertainty                                          Division
                                               (dB)         Distribution                    Coefficient     Uncertainty
                   Receiver Reading           0.12          Rectangular         1.732           1            0.069284
                  Cable Insertion Loss        0.21            Normal              2             1              0.105
                  Filter Insertion Loss       0.25            Normal              2             1              0.125
                     Antenna Factor           0.65            Normal              2             1              0.325
                 Receiver CW accuracy           0.5         Rectangular         1.732           1           0.2886836
               Pulse Amplitude Response         1.5         Rectangular         1.732           1           0.86605081
                     PRF Response               1.5         Rectangular         1.732           1           0.86605081
               Mismatch Filter - Receiver     0.25            U-Shape           1.414           1            0.1768033
                    NSA Calibration             4.0           U-Shape           1.414           1           2.8288543
              Combined Standard Uncertainty                                                                 3.0059131
              Expanded Uncertainty (K=2)                                                                    6.0118262
The total derived measurement uncertainty is +/- 6.00 dB.

 9.2     Radiated Emissions (1GHz to 40GHz)
         The test is to measure the radiated emissions of the EUT.

         Some error sources that can contribute to the total uncertainty:
         -   Uncertainty of the receiver
         -   Uncertainty of the antenna
         -   Uncertainty of cables
         -   Uncertainty due to the mismatches
         -   VSWR Calibration
         -   Etc., details see the below table

                                              Value            Probability                    Sensitivity    Expanded
              Source of Uncertainty                                              Division
                                               (dB)           Distribution                    Coefficient    Uncertainty
                Receiver Reading              0.12            Rectangular         1.732           1          0.0692840
              Cable Insertion Loss            0.21              Normal              2             1          0.1050000
               Filter Insertion Loss          0.25              Normal              2             1          0.1250000
                 Antenna Factor               0.65              Normal              2             1          0.3250000
             Receiver CW accuracy               0.5           Rectangular         1.732           1          0.2886836
           Pulse Amplitude Response             1.5           Rectangular         1.732           1          0.8660508
                  PRF Response                  1.5           Rectangular         1.732           1          0.8660508
            Mismatch Filter - Receiver        0.25              U-Shape           1.414           1          0.1768033
                VSWR Calibration                2.0             U-Shape           1.414           1          1.4144272
           Combined Standard Uncertainty                                                                       4.2363
           Expanded Uncertainty (K=2)                                                                          8.4726
         The total derived measurement uncertainty is +/- 8.47 dB.


         775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                               Visit us at: www.siemic.com; Follow us at:


                                                             Test report No.   FCC IC_RF_SL17090601-SEV-051
                                                             Page              13 of 24



 9.3     RF conducted measurement
         The test is to measure the RF output power from the EUT.

         Some error sources that can contribute to the total uncertainty:

         -       Uncertainty of the Reference Level Uncertainty
         -       Uncertainty of variable attenuators
         -       Uncertainty of cables
         -       Uncertainty due to the mismatches

                                         Value              Probability        Division   Sensitivity   Expanded
             Source of Uncertainty        (dB)              Distribution                  Coefficient   Uncertainty
            Reference Level            0.12              Rectangular            1.732         1         0.069284
          Cable Insertion Loss         0.21                Normal                 2           1            0.105
              Attenuator               0.25                Normal                 2           1            0.125
               Mismatch                0.25               U-Shape               1.414         1         0.1768033
         Combined Standard Uncertainty                                                                   0.476087
         Expanded Uncertainty (K=2)                                                                      0.952174

The total derived measurement uncertainty is +/- 0.95 dB.




         775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                                Visit us at: www.siemic.com; Follow us at:


                                                               Test report No.    FCC IC_RF_SL17090601-SEV-051
                                                               Page               14 of 24




  10 Measurements, Examination and Derived Results
   10.1 Radiated Spurious Emissions in restricted band
  Requirement(s):
Spec                     Item          Requirement                                                                           Applicable
                                       For non-restricted band, In any 100 kHz bandwidth outside the frequency band in
                                       which the spread spectrum or digitally modulated intentional radiator is operating,
                                       the radio frequency power that is produced by the intentional radiator shall be at
                                       least 20 dB or 30dB below that in the 100 kHz bandwidth within the band that                 ☒
                              a)
                                       contains the highest level of the desired power, determined by the measurement
  47CFR§15.247(d),                     method on output power to be used. Attenuation below the general limits
    RSS210(A8.5)                       specified in § 15.209(a) is not required
                                        ☐ 20 dB down          ☒ 30 dB down
                                       or restricted band, emission must also comply with the radiated emission limits
                              b)                                                                                                    ☒
                                       specified in 15.209




       Test Setup




                         1.            The EUT was switched on and allowed to warm up to its normal operating condition.
                         2.            The test was carried out at the selected frequency points obtained from the EUT characterisation.
                                       Maximization of the emissions, was carried out by rotating the EUT, changing the antenna polarization,
                                       and adjusting the antenna height in the following manner:
                                       a.        Vertical or horizontal polarisation (whichever gave the higher emission level over a full
       Procedure                                 rotation of the EUT) was chosen.
                                       b.        The EUT was then rotated to the direction that gave the maximum emission.
                                       c.        Finally, the antenna height was adjusted to the height that gave the maximum emission.
                         3.            An average measurement was then made for that frequency point.
                         4.            Steps 2 and 3 were repeated for the next frequency point, until all selected frequency points were
                                       measured.
                         The EUT was scanned up to 40GHz. Both horizontal and vertical polarities were investigated. The results
        Remark           show only the worst case. Radiated measurement was measured with antenna port terminated, there isn’t
                         outstanding emission found at the edge of restricted frequency, within x dB margin
         Result          ☒ Pass                ☐ Fail



  Test Data   ☐ Yes (See below)              ☒ N/A
  Test Plot   ☒ Yes (See below)              ☐ N/A
  Test was done by Anish Kumar at 10m chamber.


           775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                                   Visit us at: www.siemic.com; Follow us at:


                                                      Test report No.   FCC IC_RF_SL17090601-SEV-051
                                                      Page              15 of 24


Restricted Band Measurement Plots:




           Restricted Band BDR 2402MHz                                        Restricted Band BDR 2480MHz




            Restricted Band EDR 2402MHz                                       Restricted Band EDR 2480MHz




       775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                           Visit us at: www.siemic.com; Follow us at:


                                                             Test report No.     FCC IC_RF_SL17090601-SEV-051
                                                             Page                16 of 24



 10.2 Radiated Spurious Emissions below 1GHz
Requirement(s):

 Spec                  Item    Requirement                                                                               Applicable
                               Except higher limit as specified elsewhere in other section, the emissions from the
                               low-power radio-frequency devices shall not exceed the field strength levels
                               specified in the following table and the level of any unwanted emissions shall not
                               exceed the level of the fundamental emission. The tighter limit applies at the band
 47CFR§15.247(d)               edges                                                                                           ☒
                         a)
   RSS247 (5.5)                         Frequency range (MHz)                        Field Strength (uV/m)
                                               30 – 88                                        100
                                               88 – 216                                       150
                                               216 960                                        200
                                              Above 960                                       500




    Test Setup




                       1.        The EUT was switched on and allowed to warm up to its normal operating condition.
                       2.        The test was carried out at the selected frequency points obtained from the EUT characterisation.
                                 Maximization of the emissions, was carried out by rotating the EUT, changing the antenna
                                 polarization, and adjusting the antenna height in the following manner:
                                 a.         Vertical or horizontal polarisation (whichever gave the higher emission level over a full
    Procedure                               rotation of the EUT) was chosen.
                                 b.         The EUT was then rotated to the direction that gave the maximum emission.
                                 c.         Finally, the antenna height was adjusted to the height that gave the maximum emission.
                       3.        A Quasi-peak measurement was then made for that frequency point.
                       4.        Steps 2 and 3 were repeated for the next frequency point, until all selected frequency points were
                                 measured.
                       The EUT was scanned up to 1GHz. Both horizontal and vertical polarities were investigated. The results
        Remark
                       show only the worst case.
        Result         ☒ Pass            ☐ Fail


Test Data      ☒ Yes (See below)           ☐ N/A

Test Plot     ☒ Yes (See below)            ☐ N/A
Test was done by Anish Kumar at 10m chamber.




            775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                                Visit us at: www.siemic.com; Follow us at:


                                                               Test report No.         FCC IC_RF_SL17090601-SEV-051
                                                               Page                    17 of 24




Radiated Emission Test Results (Below 1GHz)

            Test specification                 below 1GHz
                                               Temp (°C):                                         26.1
     Environmental Conditions:                 Humidity (%)                                       47.5
                                               Atmospheric (mbar):                                1020
             Mains Power:                      120VAC, 60Hz                                                    Result            Pass
              Tested by:                       Anish Kumar
              Test Date:                       10/13/2017
              Remarks:                         TX MODE DH5 2402 MHz




 Frequency        Raw       Cable         AF        Level    Measurement                  Hgt      Azt       Limit      Margin     Pass
                                                                                 Pol
    MHz           dBuV      Loss          dB       dBuV/m       Type                      cm       Deg      dBuV/m       dB        /Fail

   207.43         39.05      12.9       -24.81     27.13      Quasi Max          H        136      356       43.50      -16.37     Pass
    47.95         51.02     11.56       -26.63     35.95      Quasi Max          V        101      151       40.00      -4.05      Pass
   191.99          42.5     12.78       -25.52     29.76      Quasi Max          H        150      323       43.50      -13.74     Pass
   213.31         45.08     12.94       -25.71      32.3      Quasi Max          H        161      356       43.50      -11.20     Pass
   105.65         47.11     12.07       -24.96     34.23      Quasi Max          V        382      12        43.50      -9.27      Pass
   224.00         42.36     13.03       -25.5      29.89      Quasi Max          H        176      36        46.00      -16.11     Pass

Note: Both horizontal and vertical polarities were investigated. The results above show only the worst case.




         775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                                    Visit us at: www.siemic.com; Follow us at:


                                                               Test report No.         FCC IC_RF_SL17090601-SEV-051
                                                               Page                    18 of 24




            Test specification                 below 1GHz
                                               Temp (°C):                                         26.1
     Environmental Conditions:                 Humidity (%)                                       47.5
                                               Atmospheric (mbar):                                1020
             Mains Power:                      120VAC, 60Hz                                                    Result            Pass
              Tested by:                       Anish Kumar
              Test Date:                       10/13/2017
              Remarks:                         TX MODE 3DH5 2437 MHz




 Frequency        Raw       Cable         AF        Level    Measurement                  Hgt      Azt       Limit      Margin     Pass
                                                                                 Pol
    MHz           dBuV      Loss          dB       dBuV/m       Type                      cm       Deg      dBuV/m       dB        /Fail

   207.41         31.88      12.9       -24.81     19.97      Quasi Max          H        329      21        43.50      -23.53     Pass
   199.95         40.27     12.85       -24.54     28.58      Quasi Max          H        237      347       43.50      -14.92     Pass
    47.99         51.48     11.56       -26.65     36.39      Quasi Max          V        102      110       40.00      -3.61      Pass
   202.75         39.45     12.87       -24.33     27.99      Quasi Max          H        181      174       43.50      -15.51     Pass
   204.81         41.96     12.88       -24.18     30.66      Quasi Max          H        182      176       43.50      -12.84     Pass
   210.87         34.94     12.92       -25.55     22.31      Quasi Max          H        100      147       43.50      -21.19     Pass

Note: Both horizontal and vertical polarities were investigated. The results above show only the worst case.




         775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                                    Visit us at: www.siemic.com; Follow us at:


                                                                  Test report No.    FCC IC_RF_SL17090601-SEV-051
                                                                  Page               19 of 24




   10.3 Radiated Spurious Emissions between 1GHz – 26.5GHz
  Requirement(s):
Spec                        Item          Requirement                                                                           Applicable
                                          For non-restricted band, In any 100 kHz bandwidth outside the frequency band in
                                          which the spread spectrum or digitally modulated intentional radiator is operating,
                                          the radio frequency power that is produced by the intentional radiator shall be at
                                          least 20 dB or 30dB below that in the 100 kHz bandwidth within the band that                 ☒
                                 a)
                                          contains the highest level of the desired power, determined by the measurement
  47CFR§15.247(d),                        method on output power to be used. Attenuation below the general limits
    RSS210(A8.5)                          specified in § 15.209(a) is not required
                                           ☐ 20 dB down          ☒ 30 dB down
                                          or restricted band, emission must also comply with the radiated emission limits
                                 b)                                                                                                    ☒
                                          specified in 15.209




       Test Setup




                            1.            The EUT was switched on and allowed to warm up to its normal operating condition.
                            2.            The test was carried out at the selected frequency points obtained from the EUT characterisation.
                                          Maximization of the emissions, was carried out by rotating the EUT, changing the antenna polarization,
                                          and adjusting the antenna height in the following manner:
                                          a.        Vertical or horizontal polarisation (whichever gave the higher emission level over a full
       Procedure                                    rotation of the EUT) was chosen.
                                          b.        The EUT was then rotated to the direction that gave the maximum emission.
                                          c.        Finally, the antenna height was adjusted to the height that gave the maximum emission.
                            3.            An average measurement was then made for that frequency point.
                            4.            Steps 2 and 3 were repeated for the next frequency point, until all selected frequency points were
                                          measured.

                            The EUT was scanned up to 40GHz. Both horizontal and vertical polarities were investigated. The results
        Remark
                            show only the worst case. There isn’t outstanding emission found at the edge of restricted frequency.

         Result             ☒ Pass                ☐ Fail



  Test Data       ☒ Yes (See below)              ☐ N/A

  Test Plot     ☐ Yes (See below)               ☒ N/A
  Test was done by Anish Kumar at 10m chamber.


              775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                                      Visit us at: www.siemic.com; Follow us at:


                                                           Test report No.           FCC IC_RF_SL17090601-SEV-051
                                                           Page                      20 of 24




  Radiated Emission Test Results (Above 1GHz)

  Bluetooth BDR – 2402MHz

                       Cable
Frequency     Raw                AF        Level       Measurement             Pol          Hgt     Azt       Limit    Margin   Pass
                       Loss
  (MHz)      (dBuV)             (dB)     (dBuV/m)         Type                (V/H)        (cm)    (Deg)    (dBuV/m)    (dB)    /Fail
                       (dB)
 7202.74      40.13    7.36    -11.59      35.9          Peak Max              V           202      267        74      -38.1    Pass
 9607.57      39.81    7.89    -10.42     37.28          Peak Max              H           163      227        74      -36.72   Pass
 4803.41      39.97    7.04    -17.29     29.71          Peak Max              H           190       0         74      -44.29   Pass
 7202.74      27.76    7.36    -11.59     23.54        Average Max             V           202      267        54      -30.46   Pass
 9607.57      28.19    7.89    -10.42     25.66        Average Max             H           163      227        54      -28.34   Pass
 4803.41      27.47    7.04    -17.29     17.21        Average Max             H           190       0         54      -36.79   Pass

  Bluetooth BDR – 2441MHz

                      Cable
Frequency     Raw                AF       Level        Measurement            Pol                   Azt       Limit    Margin   Pass
                      Loss                                                              Hgt (cm)
  (MHz)      (dBuV)             (dB)    (dBuV/m)          Type               (V/H)                 (Deg)    (dBuV/m)    (dB)    /Fail
                      (dB)
 7324.23      39.86    7.34    -11.53     35.66         Peak Max              V            161      146        74      -38.34   Pass
 9766.40      39.58    7.95    -10.3      37.24         Peak Max              V            99       210        74      -36.76   Pass
 4881.08      40.34    7.06    -17.07     30.33         Peak Max              H            167      248        74      -43.67   Pass
 7324.23      27.6     7.34    -11.53      23.4       Average Max             V            161      146        54      -30.6    Pass
 9766.40      27.19    7.95     -10.3     24.85       Average Max             V            99       210        54      -29.16   Pass
 4881.08      27.74    7.06    -17.07     17.72       Average Max             H            167      248        54      -36.28   Pass

  Bluetooth BDR – 2480MHz

                      Cable
Frequency     Raw                AF       Level       Measurement             Pol                   Azt       Limit    Margin   Pass
                      Loss                                                              Hgt (cm)
  (MHz)      (dBuV)             (dB)    (dBuV/m)         Type                (V/H)                 (Deg)    (dBuV/m)    (dB)    /Fail
                      (dB)
7440.37      39.88    7.32     -11.44     35.76         Peak Max              H           217       81         74      -38.24   Pass
9922.34      39.84    8.02     -10.16     37.7          Peak Max              V            102      177        74       -36.3   Pass
4959.89      39.74    7.08     -16.89     29.93         Peak Max              H           182       145        74      -44.07   Pass
7440.37      27.64    7.32     -11.44     23.51       Average Max             H            217      81         54      -30.49   Pass
9922.34      27.66    8.02     -10.16     25.52       Average Max             H            178       8         54      -28.48   Pass
4959.89      27.99    7.08     -16.89     18.18       Average Max             H            182      145        54      -35.82   Pass




            775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                                Visit us at: www.siemic.com; Follow us at:


                                                           Test report No.           FCC IC_RF_SL17090601-SEV-051
                                                           Page                      21 of 24



  EDR – 2402MHz

                       Cable
Frequency     Raw                AF        Level       Measurement             Pol          Hgt     Azt       Limit    Margin   Pass
                       Loss
  (MHz)      (dBuV)             (dB)     (dBuV/m)         Type                (V/H)        (cm)    (Deg)    (dBuV/m)    (dB)    /Fail
                       (dB)
 9606.07      39.27    7.89    -10.42     36.73          Peak Max              H           101      194        74      -37.27   Pass
 7203.22      39.34    7.36    -11.59     35.11          Peak Max              V           210      164        74      -38.89   Pass
 4803.48      39.39    7.04    -17.29     29.13          Peak Max              H           165      274        74      -44.87   Pass
 9606.07      27.78    7.89    -10.42     25.24        Average Max             H           101      194        54      -28.76   Pass
 7203.22      27.61    7.36    -11.59     23.39        Average Max             V           210      164        54      -30.61   Pass
 4803.48      27.23    7.04    -17.29     16.97        Average Max             H           165      274        54      -37.03   Pass

  EDR – 2441MHz

                      Cable
Frequency     Raw                AF       Level        Measurement            Pol                   Azt       Limit    Margin   Pass
                      Loss                                                              Hgt (cm)
  (MHz)      (dBuV)             (dB)    (dBuV/m)          Type               (V/H)                 (Deg)    (dBuV/m)    (dB)    /Fail
                      (dB)
 9766.80      39.7     7.95     -10.3     37.36         Peak Max              V            167      290        74      -36.64   Pass
 7322.86      39.31    7.34    -11.53     35.12         Peak Max              V            156      124        74      -38.88   Pass
 4881.92      40.31    7.06    -17.07     30.29         Peak Max              H            203      105        74      -43.71   Pass
 9766.80      27.42    7.95     -10.3     25.08       Average Max             V            167      290        54      -28.92   Pass
 7322.86      27.54    7.34    -11.53     23.35       Average Max             V            156      124        54      -30.65   Pass
 4881.92      27.71    7.06    -17.07      17.7       Average Max             H            203      105        54      -36.3    Pass

  EDR – 2480MHz

                      Cable
Frequency     Raw                AF       Level       Measurement             Pol                   Azt       Limit    Margin   Pass
                      Loss                                                              Hgt (cm)
  (MHz)      (dBuV)             (dB)    (dBuV/m)         Type                (V/H)                 (Deg)    (dBuV/m)    (dB)    /Fail
                      (dB)
9921.94      39.67    8.02     -10.16     37.53         Peak Max              V           196       260        74      -36.47   Pass
7440.64      39.24    7.32     -11.44     35.12         Peak Max              H           178       290        74      -38.88   Pass
4958.64       38.7    7.08     -16.89     28.89         Peak Max              H           244       177        74      -45.11   Pass
9921.94      27.67    8.02     -10.16     25.53       Average Max             V            196      260        54      -28.47   Pass
7440.64      27.53    7.32     -11.44     23.41       Average Max             H            178      290        54      -30.59   Pass
4958.64      26.47    7.08     -16.89     16.66       Average Max             H            244      177        54      -37.35   Pass




            775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                                Visit us at: www.siemic.com; Follow us at:


                                                      Test report No.   FCC IC_RF_SL17090601-SEV-051
                                                      Page              22 of 24




Annex A. TEST INSTRUMENT

         Instrument                    Model                 Serial #      Cal Date    Cal Cycle       Cal Due     In use

    Conducted Emissions
       R & S Receiver                  ESIB 40               100179       06/08/2017    1 Year     06/08/2018
        CHASE LISN                    MN2050B                 1018        08/07/2016    1 Year     08/07/2017
     Radiated Emissions
      Spectrum Analyzer                N9010A             10SL0219        08/20/2016    1 Year     08/20/2018
       RF Preamplifier                LPA-6-30            11140711        02/19/2017    1 Year     02/19/2018
 Bi-Log antenna (30MHz~2GHz)             JB1              A030702         08/12/2016    1 Year     08/12/2018
 Horn Antenna (1GHz~26GHz)              3115                 100059       08/25/2016    1 Year     08/25/2018
       10 Meters SAC                    10M                    N/A        09/05/2016    1 Year     09/05/2018
 RF Conducted Measurement
      Spectrum Analyzer                N9010A             10SL0219        08/20/2016    1 Year     08/20/2017




       775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                           Visit us at: www.siemic.com; Follow us at:


                                                           Test report No.     FCC IC_RF_SL17090601-SEV-051
                                                           Page                23 of 24




Annex B. SIEMIC Accreditation

        Accreditations         Document                                          Scope / Remark

ISO 17025 (A2LA)                           Please see the documents for the detailed scope

ISO Guide 65 (A2LA)                        Please see the documents for the detailed scope

TCB Designation                            A1, A2, A3, A4, B1, B2, B3, B4, C

FCC DoC Accreditation                      FCC Declaration of Conformity Accreditation

FCC Site Registration                      3 meter site

FCC Site Registration                      10 meter site

IC Site Registration                       3 meter site

IC Site Registration                       10 meter site

                                           Radio & Telecommunications Terminal Equipment:
                                           EN45001 – EN ISO/IEC 17025
EU NB
                                           Electromagnetic Compatibility:
                                           EN45001 – EN ISO/IEC 17025

Singapore iDA
                                           Phase I, Phase II
CB(Certification Body)

Vietnam MIC
                                           Please see the document for the detailed scope
CAB Accreditation

                                           (Phase II) OFCA Foreign Certification Body for Radio and Telecom
Hong Kong OFCA
                                           (Phase I) Conformity Assessment Body for Radio and Telecom

                                           Radio: Scope A – All Radio Standard Specification in Category I
Industry Canada CAB
                                           Telecom: CS-03 Part I, II, V, VI, VII, VIII




         775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                             Visit us at: www.siemic.com; Follow us at:


                                                        Test report No.     FCC IC_RF_SL17090601-SEV-051
                                                        Page                24 of 24




                                           Radio: A1. Terminal equipment for purpose of calling
Japan Recognized Certification
                                           Telecom: B1. Specified radio equipment specified in Article 38-2, Paragraph 1, Item
Body Designation
                                           1 of the Radio Law

                                           EMI: KCC Notice 2008-39, RRL Notice 2008-3: CA Procedures for EMI
                                           KN22: Test Method for EMI
                                           EMS: KCC Notice 2008-38, RRL Notice 2008-4: CA Procedures for EMS
                                           KN24, KN61000-4-2, -4-3, -4-4, -4-5, -4-6, -4-8, -4-11: Test Method for EMS

Korea CAB Accreditation                    Radio: RRL Notice 2008-26, RRL Notice 2008-2, RRL Notice 2008-10,
                                           RRL Notice 2007-49, RRL Notice 2007-20, RRL Notice 2007-21, RRL Notice 2007-
                                           80, RRL Notice 2004-68

                                           Telecom: President Notice 20664, RRL Notice 2007-30, RRL Notice 2008-7 with
                                           attachments 1, 3, 5, 6; President Notice 20664, RRL Notice 2008-7 with attachment 4

                                           LP0002, PSTN01, ADSL01, ID0002, IS6100, CNS14336, PLMN07, PLMN01,
Taiwan NCC CAB Recognition
                                           PLMN08

Taiwan BSMI CAB Recognition                CNS 13438

                                           R-3083: Radiation 3 meter site
Japan VCCI                                 C-3421: Main Ports Conducted Interference Measurement
                                           T-1597: Telecommunication Ports Conducted Interference Measurement

                                           EMC: AS/NZS CISPR 11, AS/NZS CISPR 14.1, AS/NZS CISPR22, AS/NZS
                                           61000.6.3, AS/NZS 61000.6.4

                                           Radio communications: AS/NZS 4281, AS/NZS 4268, AS/NZS 4280.1,
                                           AS/NZS 4280.2, AS/NZS 4295, AS/NZS 4582, AS/NZS 4583, AS/NZS 4769.1,
Australia CAB Recognition
                                           AS/NZS 4769.2, AS/NZS 4770, AS/NZS 4771

                                           Telecommunications: AS/ACIF S002:05, AS/ACIF S003:06, AS/ACIF S004:06
                                           AS/ACIF S006:01, AS/ACIF S016:01, AS/ACIF S031:01, AS/ACIF S038:01,
                                           AS/ACIF S040:01, AS/ACIF S041:05, AS/ACIF S043.2:06, AS/ACIF S60950.1

                                           AS/ACIF S002, AS/ACIF S003, AS/ACIF S004, AS/ACIF S006, AS/ACIF
Australia NATA Recognition                 S016,AS/ACIF S031, AS/ACIF S038, AS/ACIF S040, AS/ACIF S041, AS/ACIF
                                           S043.2




        775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                             Visit us at: www.siemic.com; Follow us at:



Document Created: 2017-11-14 10:55:49
Document Modified: 2017-11-14 10:55:49

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC