RF Exposure info

FCC ID: AEZCPE-400-270

RF Exposure Info

Download: PDF
FCCID_721213

Declaration on radiation safety standard conformance


To whom it may concern:

Sanyo Electric Co., Ltd.
1-1 Sanyo-cho Daito City
Osaka 574-8534
Japan

declares that the following product

FCC ID            :   AEZCPE-400-270
Model number      :   CPE-400-270
Description       :   W-CDMA Subscriber Terminal
Equipment class   :   Licensed non-broadcast station transmitter

has a maximum e.i.r.p. of 31.2 dBm (1318 mW) in the frequency range of 2305 - 2315 MHz.

The prediction of the power density at 20 cm distance of the radiating structures of the product can be
calculated as follows (in accordance with OET Bulletin 65 (edition 97-01), page 19, equation 4):


S = EIRP / (4*π * R2)

S = EIRP / (4* π *R2)       = 1318 mW / (4 * π *(20cm)2) = 0.26 mW/cm2 (limit = 1.0 mW/cm2)


This means that the product as defined above fulfills the requirements on power density for general
population/uncontrolled exposure with reference to table 1 (B) of 47 CFR Part 1.1310 where the limit for
power density in the frequency range of 1.5 - 100.0 GHz has been set to 1.0 mW/cm2.