Test Report

FCC ID: ACJFZN1D

Test Report

Download: PDF
FCCID_3900151

                                        PCTEST ENGINEERING LABORATORY, INC.
                                                        7185 Oakland Mills Road, Columbia, MD 21046 USA
                                                              Tel. 410.290.6652 / Fax 410.290.6654
                                                                      http://www.pctest.com

                                                               MEASUREMENT REPORT
                                                                                 FCC Part 15B

  Applicant Name:                                                                                Date of Testing:
  Panasonic Corporation of North America                                                         5/1-6/22/2018
  Two Riverfront Plaza, 9th Floor                                                                Test Site/Location:
  Newark, NJ 07102-5490                                                                          PCTEST Lab. Columbia, MD, USA
  United States                                                                                  Test Report Serial No.:
                                                                                                 1M1804230079-13-R1.ACJ


  FCC ID:                                                            ACJFZN1D
  APPLICANT:                                                         Panasonic Corporation of North America




  Application Type:                                                  Certification
  Model:                                                             FZ-N1EB
  Additional Model(s):                                               FZ-N1EC
  EUT Type:                                                          Portable Handset
  FCC Classification:                                                Part 15 Class B Computing Device Peripheral (JBP)
  FCC Rule Part(s):                                                  FCC Part 15 Subpart B
  Test Procedure(s):                                                 ANSI C63.4-2014




  This equipment has been shown to be capable of compliance with the applicable technical standards as indicated in the measurement report
  and has been tested in accordance with the measurement procedures specified in ANSI C63.4-2014 (See Test Report).These
  measurements were performed with no deviation from the standards. Test results reported herein relate only to the item(s) tested.

  This revised Test Report (S/N: 1M1804230079-13-R1.ACJ) supersedes and replaces the previously issued test report (S/N: 1M1804230079-
  13.ACJ) on the same subject device for the same type of testing as indicated. Please discard or destroy the previously issued test report(s)
  and dispose of it accordingly.


  I attest to the accuracy of data. All measurements reported herein were performed by me or were made under my supervision and are
  correct to the best of my knowledge and belief. I assume full responsibility for the completeness of these measurements and vouch for the
  qualifications of all persons taking them.




                                                                               MEASUREMENT REPORT                                                               Approved by:
FCC ID: ACJFZN1D
                                                                                  (CERTIFICATION)                                                               Quality Manager
Test Report S/N:                  Test Dates:                       EUT Type:
                                                                                                                                                                Page 1 of 18
1M1804230079-13.ACJ               5/1-6/22/2018                    Portable Handset
© 2018 PCTEST Engineering Laboratory, Inc.                                                                                                                                    V 8.0 04/05/2018
All rights reserved. Unless otherwise specified, no part of this report may be reproduced or utilized in any part, form or by any means, electronic or mechanical, including photocopying and
microfilm, without permission in writing from PCTEST Engineering Laboratory, Inc. If you have any questions about this international copyright or have an enquiry about obtaining additional
rights to this report or assembly of contents thereof, please contact INFO@PCTEST.COM.


                                               T A B L E                       O F             C O N T E N T S

        1.0         Introduction ...................................................................................................................................... 3
                    1.1      Scope..................................................................................................................................................... 3
                    1.1      PCTEST Test Location .......................................................................................................................... 3
                    1.2      Test Facility / Accreditations .................................................................................................................. 3
        2.0         PRODUCT INFORMATION ............................................................................................................. 4
                    2.1      Equipment Description ........................................................................................................................... 4
                    2.2      Device Capabilities ................................................................................................................................ 4
                    2.3      Test Configuration ................................................................................................................................. 4
                    2.4      EMI Suppression Device(s)/Modifications.............................................................................................. 4
        3.0         DESCRIPTION OF TESTS .............................................................................................................. 5
                    3.1      Evaluation Procedure ............................................................................................................................ 5
                    3.2      AC Line Conducted Emissions .............................................................................................................. 5
                    3.3      Radiated Emissions ............................................................................................................................... 6
                    3.4      Environmental Conditions ...................................................................................................................... 6
        4.0         SAMPLE CALCULATIONS .............................................................................................................. 7
                    4.1      Conducted Emission Measurement Sample Calculation ....................................................................... 7
                    4.2      Radiated Emission Measurement Sample Calculation .......................................................................... 7
        5.0         Measurement Uncertainty ................................................................................................................ 8
        6.0         TEST EQUIPMENT CALIBRATION DATA ...................................................................................... 9
        7.0         TEST DATA ................................................................................................................................... 10
                    7.1      Summary ............................................................................................................................................. 10
                    7.2      Test Support Equipment ...................................................................................................................... 10
                    7.3      Radiated Measurement Data ............................................................................................................... 11
                    7.4      Line Conducted Measurement Data .................................................................................................... 15
        8.0         CONCLUSION ............................................................................................................................... 18




                                                                               MEASUREMENT REPORT                                                                 Approved by:
FCC ID: ACJFZN1D
                                                                                  (CERTIFICATION)                                                                 Quality Manager
Test Report S/N:                  Test Dates:                       EUT Type:
                                                                                                                                                                  Page 2 of 18
1M1804230079-13.ACJ               5/1-6/22/2018                    Portable Handset
© 2018 PCTEST Engineering Laboratory, Inc.                                                                                                                                    V 8.0 04/05/2018
All rights reserved. Unless otherwise specified, no part of this report may be reproduced or utilized in any part, form or by any means, electronic or mechanical, including photocopying and
microfilm, without permission in writing from PCTEST Engineering Laboratory, Inc. If you have any questions about this international copyright or have an enquiry about obtaining additional
rights to this report or assembly of contents thereof, please contact INFO@PCTEST.COM.


1.0              INTRODUCTION

1.1           Scope
Measurement and determination of electromagnetic emissions (EMC) of radio frequency devices including
intentional and/or unintentional radiators for compliance with the technical rules and regulations of the Federal
Communications Commission.

1.1           PCTEST Test Location
These measurement tests were conducted at the PCTEST Engineering Laboratory, Inc. facility located at 7185
Oakland Mills Road, Columbia, MD 21046. The facility is 0.4 miles North of the FCC laboratory, and the ambient
signal and ambient signal strength are approximately equal to those of the FCC laboratory. The measurement
facility is compliant with the test site requirements specified in ANSI C63.4-2014.

1.2           Test Facility / Accreditations
Measurements were performed at PCTEST Engineering Lab located in Columbia, MD 21046, U.S.A.

•     PCTEST is an ISO 17025-2005 accredited test facility under the American Association for Laboratory
      Accreditation (A2LA) with Certificate number 2041.01 for Specific Absorption Rate (SAR), Hearing Aid
      Compatibility (HAC) testing, where applicable, and Electromagnetic Compatibility (EMC) testing for FCC and
      Innovation, Science, and Economic Development Canada rules.

•     PCTEST TCB is a Telecommunication Certification Body (TCB) accredited to ISO/IEC 17065-2012 by A2LA
      (Certificate number 2041.03) in all scopes of FCC Rules and ISED Standards (RSS).”

•     PCTEST facility is a registered (2451B) test laboratory with the site description on file with ISED.




                                                                               MEASUREMENT REPORT                                                               Approved by:
FCC ID: ACJFZN1D
                                                                                  (CERTIFICATION)                                                               Quality Manager
Test Report S/N:                  Test Dates:                       EUT Type:
                                                                                                                                                                Page 3 of 18
1M1804230079-13.ACJ               5/1-6/22/2018                    Portable Handset
© 2018 PCTEST Engineering Laboratory, Inc.                                                                                                                                    V 8.0 04/05/2018
All rights reserved. Unless otherwise specified, no part of this report may be reproduced or utilized in any part, form or by any means, electronic or mechanical, including photocopying and
microfilm, without permission in writing from PCTEST Engineering Laboratory, Inc. If you have any questions about this international copyright or have an enquiry about obtaining additional
rights to this report or assembly of contents thereof, please contact INFO@PCTEST.COM.


2.0              PRODUCT INFORMATION


2.1           Equipment Description
The Equipment Under Test (EUT) is the Panasonic Portable Handset FCC ID: ACJFZN1D. The test data
contained in this report pertains only to the emissions due to the digital circuitry of the EUT.

Test Device Serial No.: 02112

2.2           Device Capabilities
This device contains the following capabilities:

850/1900 WCDMA/HSPA, Multi-band LTE, 802.11b/g/n WLAN, 802.11a/n/ac UNII, Bluetooth (1x, EDR, LE), NFC

2.3           Test Configuration
The EUT was tested with a laptop PC connected via USB interface port. The EUT was exercised during testing by
means of software installed on the PC. Since the EUT is a peripheral device, the host PC was populated with
another USB device and an additional peripheral device with a non-USB interface, as shown in Table 7-2, thus
satisfying the minimum system requirement of two different I/O interfaces. All equipment is placed on the test
table top and arranged in a typical configuration in accordance with ANSI C63.4-2014 and manipulated to obtain
worst case emissions.

For more information please see Section 7.0 for test data and the test setup photos document for the test setup
photographs.

2.4           EMI Suppression Device(s)/Modifications
No EMI suppression device(s) were added and no modifications were made during testing.




                                                                               MEASUREMENT REPORT                                                               Approved by:
FCC ID: ACJFZN1D
                                                                                  (CERTIFICATION)                                                               Quality Manager
Test Report S/N:                  Test Dates:                       EUT Type:
                                                                                                                                                                Page 4 of 18
1M1804230079-13.ACJ               5/1-6/22/2018                    Portable Handset
© 2018 PCTEST Engineering Laboratory, Inc.                                                                                                                                    V 8.0 04/05/2018
All rights reserved. Unless otherwise specified, no part of this report may be reproduced or utilized in any part, form or by any means, electronic or mechanical, including photocopying and
microfilm, without permission in writing from PCTEST Engineering Laboratory, Inc. If you have any questions about this international copyright or have an enquiry about obtaining additional
rights to this report or assembly of contents thereof, please contact INFO@PCTEST.COM.


3.0              DESCRIPTION OF TESTS

3.1           Evaluation Procedure
The measurement procedure described in the American National Standard for Methods of Measurement of
Radio-Noise Emission from Low-Voltage Electrical and Electronic Equipment in the Range of 9kHz to 40GHz
(ANSI C63.4-2014) was used in the measurement of the EUT.

Deviation from measurement procedure…………………………………………….....................................None

3.2           AC Line Conducted Emissions
The line-conducted facility is located inside a 10'x16'x9' shielded enclosure. The shielded enclosure is
manufactured by ETS Lindgren RF Enclosures. The shielding effectiveness of the shielded room is in accordance
with MIL-Std-285 or NSA 65-5. A 1m x 1.5m wooden table 80cm high is placed 40cm away from the vertical wall
and 80cm away from the sidewall of the shielded room. Two 10kHz-30MHz, 50/50H Line-Impedance
Stabilization Networks (LISNs) are bonded to the shielded room floor. Power to the LISNs is filtered by external
high-current high-insertion loss power line filters. The external power line filter is an ETS Lindgren Model LPRX-
4X30 (100dB Attenuation, 14kHz-18GHz) and the two EMI/RFI filters are ETS Lindgren Model LRW-2030-S1
(100dB Minimum Insertion Loss, 14kHz – 10GHz). These filters attenuate ambient signal noise from entering the
measurement lines. These filters are also bonded to the shielded enclosure.

The EUT is powered from one LISN and the support equipment is powered from the second LISN. If the EUT is a
DC-powered device, power will be derived from the source power supply it normally will be powered from and this
supply line(s) will be connected to the second LISN. All interconnecting cables more than 1 meter were shortened
to a 1 meter length by non-inductive bundling (serpentine fashion) and draped over the back edge of the test
table. All cables were at least 40cm above the horizontal reference groundplane. Power cables for support
equipment were routed down to the second LISN while ensuring that that cables were not draped over the second
LISN.

Sufficient time for the EUT, support equipment, and test equipment was allowed in order for them to warm up to
their normal operating condition. The RF output of the LISN was connected to the spectrum analyzer and
exploratory measurements were made to determine the frequencies producing the maximum emission from the
EUT. The spectrum was scanned from 150kHz to 30MHz with a spectrum analyzer. The detector function was set
to peak mode for exploratory measurements while the bandwidth of the analyzer was set to 10kHz. The EUT,
support equipment, and interconnecting cables were arranged and manipulated to maximize each emission. Once
the worst case emissions have been identified, the one EUT cable configuration/arrangement and mode of
operation that produced these emissions is used for final measurements on the same test site. The analyzer is set
to CISPR quasi-peak and average detectors with a 9kHz resolution bandwidth for final measurements.

Line conducted emissions test results are shown in Section 7.4. The EMI Receiver mode of the Agilent MXE was
used to perform ACLC emissions testing.




                                                                               MEASUREMENT REPORT                                                               Approved by:
FCC ID: ACJFZN1D
                                                                                  (CERTIFICATION)                                                               Quality Manager
Test Report S/N:                  Test Dates:                       EUT Type:
                                                                                                                                                                Page 5 of 18
1M1804230079-13.ACJ               5/1-6/22/2018                    Portable Handset
© 2018 PCTEST Engineering Laboratory, Inc.                                                                                                                                    V 8.0 04/05/2018
All rights reserved. Unless otherwise specified, no part of this report may be reproduced or utilized in any part, form or by any means, electronic or mechanical, including photocopying and
microfilm, without permission in writing from PCTEST Engineering Laboratory, Inc. If you have any questions about this international copyright or have an enquiry about obtaining additional
rights to this report or assembly of contents thereof, please contact INFO@PCTEST.COM.


3.3           Radiated Emissions
The radiated test facilities consisted of an indoor 3 meter semi-anechoic chamber used for final measurements
and exploratory measurements, when necessary. The measurement area is contained within the semi-anechoic
chamber which is shielded from any ambient interference. The test site inside the chamber is a 6m x 5.2m
elliptical, obstruction-free area in accordance with Clause 5, Figure 5.7 of ANSI C63.4-2014. A raised turntable is
used for radiated measurement. It is a continuously rotatable, remote-controlled, metallic turntable and 2 meters
(6.56 ft.) in diameter. The turn table is flush with the raised floor of the chamber in order to maintain its function as
a ground plane. Absorbers are arranged on the floor between the turn table and the antenna mast in such a way
so as to maximize the reduction of reflections for measurements above 1GHz. . An 80cm tall test table made of
Styrodur is placed on top of the turn table. For measurements above 1GHz, an additional Styrodur pedestal is
placed on top of the test table to bring the total table height to 1.5m.

For all measurements, the spectrum was scanned through all EUT azimuths and from 1 to 4 meter receive
antenna height using a broadband antenna from 30MHz up to the upper frequency shown in 15.33(b)(1)
depending on the highest frequency generated or used in the device or on which the device operates or tunes.
For frequencies above 1GHz, linearly polarized double ridge horn antennas were used. For frequencies below
30MHz, a calibrated loop antenna was used. When exploratory measurements were necessary, they were
performed at 1 meter test distance inside the semi-anechoic chamber using broadband antennas, broadband
amplifiers, and spectrum analyzers to determine the frequencies and modes producing the maximum emissions.
Sufficient time for the EUT, support equipment, and test equipment was allowed in order for them to warm up to
their normal operating condition. The test set-up was placed on top of the 1 x 1.5 meter table. The EUT, support
equipment, and interconnecting cables were arranged and manipulated to maximize each emission. Appropriate
precaution was taken to ensure that all emissions from the EUT were maximized and investigated. The system
configuration, mode of operation, turntable azimuth, and receive antenna height was noted for each frequency
found.

Final measurements were made in the semi-anechoic chamber using calibrated, linearly polarized broadband and
horn antennas. The test setup was configured to the setup that produced the worst case emissions. The spectrum
analyzer was set to investigate all frequencies required for testing to compare the highest radiated disturbances
with respect to the specified limits. The turntable containing the EUT was rotated through 360 degrees and the
height of the receive antenna was varied 1 to 4 meters and stopped at the azimuth and height producing the
maximum emission. Each emission was maximized by changing the orientation of the EUT through three
orthogonal planes and changing the polarity of the receive antenna, whichever produced the worst-case
emissions.

3.4           Environmental Conditions
The temperature is controlled within range of 15oC to 35oC. The relative humidity is controlled within range of 10%
to 75%. The atmospheric pressure is monitored within the range 86-106kPa (860-1060mbar).




                                                                               MEASUREMENT REPORT                                                               Approved by:
FCC ID: ACJFZN1D
                                                                                  (CERTIFICATION)                                                               Quality Manager
Test Report S/N:                  Test Dates:                       EUT Type:
                                                                                                                                                                Page 6 of 18
1M1804230079-13.ACJ               5/1-6/22/2018                    Portable Handset
© 2018 PCTEST Engineering Laboratory, Inc.                                                                                                                                    V 8.0 04/05/2018
All rights reserved. Unless otherwise specified, no part of this report may be reproduced or utilized in any part, form or by any means, electronic or mechanical, including photocopying and
microfilm, without permission in writing from PCTEST Engineering Laboratory, Inc. If you have any questions about this international copyright or have an enquiry about obtaining additional
rights to this report or assembly of contents thereof, please contact INFO@PCTEST.COM.


4.0              SAMPLE CALCULATIONS

4.1           Conducted Emission Measurement Sample Calculation
             @ 20.3 MHz

                           Class B limit                           = 60.0 dBV (Quasi-peak limit)
                           Reading                                 = - 57.8 dBm (calibrated quasi-peak level)
                           Convert to dBV                         = - 57.8 + 107 = 49.2 dBV


                           Margin                                  = 49.2 - 60.0 = - 10.8 dB
                                                                   = 10.8 dB below limit


4.2           Radiated Emission Measurement Sample Calculation
              @ 66.7 MHz
                           Class B limit                                         = 100 V/m = 40.0 dBV/m
                           Reading                                               = - 76.0 dBm (calibrated level)
                           Convert to dBV                                       = - 76.0 + 107 = 31.0 dBV
                           Antenna Factor + Cable Loss                           = 5.8 dB/m
                                                                   Total         = 36.8 dBV/m


                           Margin                                                = 36.8 - 40.0 = - 3.2 dB
                                                                                 = 3.2 dB below limit




                  Note:


                     Level [dBV] = 20 log 10 (Level [V/m])
                       Level [dBV] = Level [dBm] + 107




                                                                               MEASUREMENT REPORT                                                               Approved by:
FCC ID: ACJFZN1D
                                                                                  (CERTIFICATION)                                                               Quality Manager
Test Report S/N:                  Test Dates:                       EUT Type:
                                                                                                                                                                Page 7 of 18
1M1804230079-13.ACJ               5/1-6/22/2018                    Portable Handset
© 2018 PCTEST Engineering Laboratory, Inc.                                                                                                                                    V 8.0 04/05/2018
All rights reserved. Unless otherwise specified, no part of this report may be reproduced or utilized in any part, form or by any means, electronic or mechanical, including photocopying and
microfilm, without permission in writing from PCTEST Engineering Laboratory, Inc. If you have any questions about this international copyright or have an enquiry about obtaining additional
rights to this report or assembly of contents thereof, please contact INFO@PCTEST.COM.


5.0              MEASUREMENT UNCERTAINTY

The measurement uncertainties shown below were calculated in accordance with the requirements of
ANSI C63.4-2014. All measurement uncertainty values are shown with a coverage factor of k = 2 to indicate a
95% level of confidence. The measurement uncertainty shown below meets or exceeds the UCISPR measurement
uncertainty values specified in CISPR 16-4-2 and, thus, can be compared directly to specified limits to determine
compliance.


                                                  Contribution                                        Expanded Uncertainty (±dB)

                                          Conducted Disturbance                                                             3.09

                                    Radiated Disturbance (<1GHz)                                                            4.98

                                    Radiated Disturbance (>1GHz)                                                            5.07




                                                                               MEASUREMENT REPORT                                                               Approved by:
FCC ID: ACJFZN1D
                                                                                  (CERTIFICATION)                                                               Quality Manager
Test Report S/N:                  Test Dates:                       EUT Type:
                                                                                                                                                                Page 8 of 18
1M1804230079-13.ACJ               5/1-6/22/2018                    Portable Handset
© 2018 PCTEST Engineering Laboratory, Inc.                                                                                                                                    V 8.0 04/05/2018
All rights reserved. Unless otherwise specified, no part of this report may be reproduced or utilized in any part, form or by any means, electronic or mechanical, including photocopying and
microfilm, without permission in writing from PCTEST Engineering Laboratory, Inc. If you have any questions about this international copyright or have an enquiry about obtaining additional
rights to this report or assembly of contents thereof, please contact INFO@PCTEST.COM.


 6.0              TEST EQUIPMENT CALIBRATION DATA

Test Equipment Calibration is traceable to the National Institute of Standards and Technology (NIST).
Measurements antennas used during testing were calibrated in accordance to the requirements of ANSI C63.5-
2017.

  Manufacturer                   Model                                  Description                              Cal Date          Cal Interval        Cal Due         Serial Number

      Agilent           N9038A                                   MXE EMI Receiver                               6/11/2018            Annual            6/11/2019         MY51210133
   Com-Power            AL-130                              9kHz - 30MHz Loop Antenna                           10/10/2017           Biennial         10/10/2019           121034
    Pasternack          NMLC-1                         Line Conducted Emissions Cable (NM)                      5/31/2018            Annual            5/31/2019          NMLC-1
 Rohde & Schwarz         ESU26                              EMI Test Receiver (26.5GHz)                         5/21/2018            Annual            5/21/2019           100342
 Rohde & Schwarz        TS-PR8                        Preamplifier-Antenna SYS; 30MHz-8GHz                      10/19/2017           Annual           10/19/2018           102324
 Solar Electronics 8012-50-R-24-BNC                    Line Impedance Stabilization Network                     8/14/2017            Biennial          8/14/2019           310233
       Sunol              JB5                               Bi-Log Antenna (30M - 5GHz)                         4/19/2018            Biennial          4/19/2020          A051107
                                            Table 6-1. Annual Test Equipment Calibration Schedule


 Note:

 For equipment listed above that has a calibration date or calibration due date that falls within the test date range,
 care was taken to ensure that this equipment was used after the calibration date and before the calibration due
 date.




                                                                                MEASUREMENT REPORT                                                               Approved by:
  FCC ID: ACJFZN1D
                                                                                   (CERTIFICATION)                                                               Quality Manager
  Test Report S/N:                 Test Dates:                       EUT Type:
                                                                                                                                                                 Page 9 of 18
  1M1804230079-13.ACJ              5/1-6/22/2018                    Portable Handset
 © 2018 PCTEST Engineering Laboratory, Inc.                                                                                                                                    V 8.0 04/05/2018
 All rights reserved. Unless otherwise specified, no part of this report may be reproduced or utilized in any part, form or by any means, electronic or mechanical, including photocopying and
 microfilm, without permission in writing from PCTEST Engineering Laboratory, Inc. If you have any questions about this international copyright or have an enquiry about obtaining additional
 rights to this report or assembly of contents thereof, please contact INFO@PCTEST.COM.


7.0              TEST DATA

7.1           Summary


                                   Test Date(s):                               5/1 – 6/22/2018

                                   Test Engineer:                              Manoutra Nayeck




                         FCC Part 15 Section                                        Description                                             Result


                                      15.107                                Conducted Emissions                                             PASS


                                      15.109                                  Radiated Emissions                                            PASS

                                                               Table 7-1. Summary of Test Results


7.2           Test Support Equipment
1               Apple MacBook Pro                                             Model: A1465                                          S/N:       N/A

2               Apple MacBook Pro Adapter                                     Model: A1436                                          S/N:       N/A
                                                                              0.85m Unshielded AC power cord
                                                                              1.80m Unshielded DC power cord

3               Gear Head Quick WebCam Advanced                               Model: WC535I (DoC)                                   S/N:       N/A
                w/ microphone and ferrite beads                               1.4m Shielded USB Cable
                on both ends

                                                          Table 7-2. Test Support Equipment Used

Note:        See test setup photographs for actual system test setup.




                                                                               MEASUREMENT REPORT                                                               Approved by:
FCC ID: ACJFZN1D
                                                                                  (CERTIFICATION)                                                               Quality Manager
Test Report S/N:                  Test Dates:                       EUT Type:
                                                                                                                                                                Page 10 of 18
1M1804230079-13.ACJ               5/1-6/22/2018                    Portable Handset
© 2018 PCTEST Engineering Laboratory, Inc.                                                                                                                                    V 8.0 04/05/2018
All rights reserved. Unless otherwise specified, no part of this report may be reproduced or utilized in any part, form or by any means, electronic or mechanical, including photocopying and
microfilm, without permission in writing from PCTEST Engineering Laboratory, Inc. If you have any questions about this international copyright or have an enquiry about obtaining additional
rights to this report or assembly of contents thereof, please contact INFO@PCTEST.COM.


7.3           Radiated Measurement Data
§15.109


Test Overview and Limit

All out of band radiated spurious emissions are measured with a spectrum analyzer connected to a receive
antenna while the EUT is operating at maximum power and at the appropriate frequencies. Only the radiated
emissions of the configuration that produced the worst case emissions are reported in this section.

All out of band emissions appearing in a restricted band as specified in Section 15.105 of the Title 47 CFR
must not exceed the limits shown in Table 7-3 per Section 15.109.

                                                 Frequency                       Field Strength Limit
                                                    [MHz]                               [V/m]
                                                   30 – 88                                100
                                                  88 – 216                                150
                                                 216 – 960                                200
                                                    > 960                                 500
                                                 Table 7-3. 3-Meter Radiated Limits (Section 15.109)

Test Procedures Used

ANSI C63.4-2014



Test Settings
             Quasi-Peak Field Strength Measurements
                    1. Analyzer frequency set to the frequency of the radiated spurious emission of interest
                    2. RBW = 120kHz (for emissions from 30MHz – 1GHz)
                    3. Detector = quasi-peak
                    4. Sweep time = auto couple
                    5. Trace mode = max hold
                    6. Trace was allowed to stabilize


Test Setup
The EUT and measurement equipment were set up as shown test setup photos provided.




                                                                               MEASUREMENT REPORT                                                               Approved by:
FCC ID: ACJFZN1D
                                                                                  (CERTIFICATION)                                                               Quality Manager
Test Report S/N:                  Test Dates:                       EUT Type:
                                                                                                                                                                Page 11 of 18
1M1804230079-13.ACJ               5/1-6/22/2018                    Portable Handset
© 2018 PCTEST Engineering Laboratory, Inc.                                                                                                                                    V 8.0 04/05/2018
All rights reserved. Unless otherwise specified, no part of this report may be reproduced or utilized in any part, form or by any means, electronic or mechanical, including photocopying and
microfilm, without permission in writing from PCTEST Engineering Laboratory, Inc. If you have any questions about this international copyright or have an enquiry about obtaining additional
rights to this report or assembly of contents thereof, please contact INFO@PCTEST.COM.


Test Notes

1.           All modes of operation were investigated and the worst-case emissions are reported.
2.           Radiated emissions were measured from 30MHz – 30GHz to ensure that the provisions of 15.33(b)(1) are
             satisfied with respect to the upper frequency scanning range.
3.           The radiated limits for unintentional radiators at a distance of 3 meters are used in the table above, as
             specified in 15.109(a).
4.            All readings are calibrated by a signal generator with accuracy traceable to the National Institute of
              Standards and Technology (NIST).
5.           AFCL (dB/m) = Antenna Factor (dB/m) + Cable Loss (dB)
6.           Level (dBV/m) = Analyzer Reading (dBm) + AFCL (dB/m) + 107
7.           Margin (dB) = Field strength (dBV/m) – Limit (dBV/m)
8.            Measurements are made using a CISPR quasi-peak detector with a 120kHz resolution bandwidth. Above
              1GHz, peak measurements are made using a peak detector with a resolution bandwidth of 1MHz and a
              video bandwidth of 3MHz and average measurements are made with a RMS detector using a resolution
              bandwidth of 1MHz and a video bandwidth of 3MHz.
9.            Calibrated linearly polarized broadband and horn antennas were used for measurements below and
              above 1GHz, respectively. For measurements made below 1GHz, the results recorded using the
              broadband antenna are known to correlate with the results obtained by using a tuned dipole with an
              acceptable degree of accuracy. The VSWR for the measurement antennas was found to be less than 2:1.
10.           Calibrated low-loss microwaves cables and broadband amplifiers are used.




                                                                               MEASUREMENT REPORT                                                               Approved by:
FCC ID: ACJFZN1D
                                                                                  (CERTIFICATION)                                                               Quality Manager
Test Report S/N:                  Test Dates:                       EUT Type:
                                                                                                                                                                Page 12 of 18
1M1804230079-13.ACJ               5/1-6/22/2018                    Portable Handset
© 2018 PCTEST Engineering Laboratory, Inc.                                                                                                                                    V 8.0 04/05/2018
All rights reserved. Unless otherwise specified, no part of this report may be reproduced or utilized in any part, form or by any means, electronic or mechanical, including photocopying and
microfilm, without permission in writing from PCTEST Engineering Laboratory, Inc. If you have any questions about this international copyright or have an enquiry about obtaining additional
rights to this report or assembly of contents thereof, please contact INFO@PCTEST.COM.


                                                                Plot 7-1. Radiated Prescan Plot (H)




                                                                Plot 7-2. Radiated Prescan Plot (V)




                                                                               MEASUREMENT REPORT                                                               Approved by:
FCC ID: ACJFZN1D
                                                                                  (CERTIFICATION)                                                               Quality Manager
Test Report S/N:                  Test Dates:                       EUT Type:
                                                                                                                                                                Page 13 of 18
1M1804230079-13.ACJ               5/1-6/22/2018                    Portable Handset
© 2018 PCTEST Engineering Laboratory, Inc.                                                                                                                                    V 8.0 04/05/2018
All rights reserved. Unless otherwise specified, no part of this report may be reproduced or utilized in any part, form or by any means, electronic or mechanical, including photocopying and
microfilm, without permission in writing from PCTEST Engineering Laboratory, Inc. If you have any questions about this international copyright or have an enquiry about obtaining additional
rights to this report or assembly of contents thereof, please contact INFO@PCTEST.COM.


                                    Ant.         Antenna Turntable                                                           3m Field
            Frequency                                                                      Level             AFCL                       Limit                      Margin
                                    Pol.          Height  Azimuth                                                            Strength
              [MHz]                                                                       [dBm]             [dB/m]                    [dBµV/m]                      [dB]
                                   [H/V]           [cm]  [degree]                                                           [dBµV/m]

                220.81                H              124                 199              -57.07            -18.46              31.47             46.02             -14.55

                234.37                H              125                 170              -62.05            -17.58              27.37             46.02             -18.66

                240.00                H              128                 185              -48.26            -17.48              41.26             46.02              -4.76

                299.24                H                 -                  -              -65.24            -15.57              26.19             46.02             -19.83

                650.24                H                 -                  -              -73.64             -8.91              24.45             46.02             -21.57

                748.73                H                 -                  -              -74.24             -7.28              25.48             46.02             -20.54

                869.43                H                 -                  -              -73.49             -6.04              27.47             46.02             -18.56
                                                     Table 7-4. Radiated Measurements at 3-meters




                                                                               MEASUREMENT REPORT                                                               Approved by:
FCC ID: ACJFZN1D
                                                                                  (CERTIFICATION)                                                               Quality Manager
Test Report S/N:                  Test Dates:                       EUT Type:
                                                                                                                                                                Page 14 of 18
1M1804230079-13.ACJ               5/1-6/22/2018                    Portable Handset
© 2018 PCTEST Engineering Laboratory, Inc.                                                                                                                                    V 8.0 04/05/2018
All rights reserved. Unless otherwise specified, no part of this report may be reproduced or utilized in any part, form or by any means, electronic or mechanical, including photocopying and
microfilm, without permission in writing from PCTEST Engineering Laboratory, Inc. If you have any questions about this international copyright or have an enquiry about obtaining additional
rights to this report or assembly of contents thereof, please contact INFO@PCTEST.COM.


7.4           Line Conducted Measurement Data
§15.107

Test Overview and Limit

All AC line conducted spurious emissions are measured with a receiver connected to a grounded LISN while the
EUT is operating at its maximum duty cycle, at maximum power, and at the appropriate frequencies. All data rates
and modes were investigated for conducted spurious emissions. Only the conducted emissions of the
configuration that produced the worst case emissions are reported in this section.

All conducted emissions must not exceed the limits shown in the table below, per Section 15.107.

                             Frequency of emission                                              Conducted Limit (dBV)
                                    (MHz)
                                                                                     Quasi-peak                                      Average
                                          0.15 – 0.5                                  66 to 56*                                      56 to 46*
                                           0.5 – 5                                       56                                             46
                                            5 – 30                                       60                                             50
                                                                     Table 7-5. Conducted Limits

*Decreases with the logarithm of the frequency.

Test Procedures Used

ANSI C63.4-2014

Test Settings

             Quasi-Peak Field Strength Measurements

             1. Analyzer center frequency was set to the frequency of the spurious emission of interest
             2. RBW = 9kHz (for emissions from 150kHz – 30MHz)
             3. Detector = quasi-peak
             4. Sweep time = auto couple
             5. Trace mode = max hold
             6. Trace was allowed to stabilize
             Average Field Strength Measurements

             1. Analyzer center frequency was set to the frequency of the spurious emission of interest
             2. RBW = 9kHz (for emissions from 150kHz – 30MHz)
             3. Detector = RMS
             4. Sweep time = auto couple
             5. Trace mode = max hold
             6. Trace was allowed to stabilize




                                                                               MEASUREMENT REPORT                                                               Approved by:
FCC ID: ACJFZN1D
                                                                                  (CERTIFICATION)                                                               Quality Manager
Test Report S/N:                  Test Dates:                       EUT Type:
                                                                                                                                                                Page 15 of 18
1M1804230079-13.ACJ               5/1-6/22/2018                    Portable Handset
© 2018 PCTEST Engineering Laboratory, Inc.                                                                                                                                    V 8.0 04/05/2018
All rights reserved. Unless otherwise specified, no part of this report may be reproduced or utilized in any part, form or by any means, electronic or mechanical, including photocopying and
microfilm, without permission in writing from PCTEST Engineering Laboratory, Inc. If you have any questions about this international copyright or have an enquiry about obtaining additional
rights to this report or assembly of contents thereof, please contact INFO@PCTEST.COM.


Test Setup

The EUT and measurement equipment were set up as shown in the test setup photos provided.

Test Notes

1.           All Modes of operation were investigated and the worst-case emissions are reported.
2.           The limit for Class B device(s) from 150kHz to 30MHz are specified in Section 15.107.
3.           L1 = Phase; N = Neutral
4.           Corr. (dB) = Cable loss (dB) + LISN insertion factor (dB)
5.           QP/AV Level (dBµV) = QP/AV Reading (dBµV) + Factor (dB)
6.           Margin (dB) = QP/AV Limit (dBµV) – QP/AV Level (dBµV)
7.           Traces shown in plot are made using a peak detector.
8.           Deviations to the Specifications: None.




                                                                               MEASUREMENT REPORT                                                               Approved by:
FCC ID: ACJFZN1D
                                                                                  (CERTIFICATION)                                                               Quality Manager
Test Report S/N:                  Test Dates:                       EUT Type:
                                                                                                                                                                Page 16 of 18
1M1804230079-13.ACJ               5/1-6/22/2018                    Portable Handset
© 2018 PCTEST Engineering Laboratory, Inc.                                                                                                                                    V 8.0 04/05/2018
All rights reserved. Unless otherwise specified, no part of this report may be reproduced or utilized in any part, form or by any means, electronic or mechanical, including photocopying and
microfilm, without permission in writing from PCTEST Engineering Laboratory, Inc. If you have any questions about this international copyright or have an enquiry about obtaining additional
rights to this report or assembly of contents thereof, please contact INFO@PCTEST.COM.


                                                                Plot 7-3. Line Conducted Plot (L1)




                                                                 Plot 7-4. Line Conducted Plot (N)



                                                                               MEASUREMENT REPORT                                                               Approved by:
FCC ID: ACJFZN1D
                                                                                  (CERTIFICATION)                                                               Quality Manager
Test Report S/N:                  Test Dates:                       EUT Type:
                                                                                                                                                                Page 17 of 18
1M1804230079-13.ACJ               5/1-6/22/2018                    Portable Handset
© 2018 PCTEST Engineering Laboratory, Inc.                                                                                                                                    V 8.0 04/05/2018
All rights reserved. Unless otherwise specified, no part of this report may be reproduced or utilized in any part, form or by any means, electronic or mechanical, including photocopying and
microfilm, without permission in writing from PCTEST Engineering Laboratory, Inc. If you have any questions about this international copyright or have an enquiry about obtaining additional
rights to this report or assembly of contents thereof, please contact INFO@PCTEST.COM.


8.0              CONCLUSION


   The data collected relate only to the item(s) tested and show that the Panasonic Portable Handset
   FCC ID: ACJFZN1D has been tested to comply with the requirements specified in §15.107 and §15.109 of the
   FCC rules.




                                                                               MEASUREMENT REPORT                                                               Approved by:
FCC ID: ACJFZN1D
                                                                                  (CERTIFICATION)                                                               Quality Manager
Test Report S/N:                  Test Dates:                       EUT Type:
                                                                                                                                                                Page 18 of 18
1M1804230079-13.ACJ               5/1-6/22/2018                    Portable Handset
© 2018 PCTEST Engineering Laboratory, Inc.                                                                                                                                    V 8.0 04/05/2018
All rights reserved. Unless otherwise specified, no part of this report may be reproduced or utilized in any part, form or by any means, electronic or mechanical, including photocopying and
microfilm, without permission in writing from PCTEST Engineering Laboratory, Inc. If you have any questions about this international copyright or have an enquiry about obtaining additional
rights to this report or assembly of contents thereof, please contact INFO@PCTEST.COM.



Document Created: 2018-06-25 10:38:44
Document Modified: 2018-06-25 10:38:44

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC