            FCC RADIO TEST REPORT                                             Report No. : FR870418A



                           CSE Plot on Ch 39 between 30MHz ~ 3 GHz




                           CSE Plot on Ch 39 between 2 GHz ~ 25 GHz




TEL : 886-3-327-3456                                                  Page Number      : 47 of 58
FAX : 886-3-328-4978                                                  Issued Date      : Nov. 13, 2018
Report Template No.: BU5-FR15CBT Version 2.1                          Report Version   : 01


            FCC RADIO TEST REPORT                                             Report No. : FR870418A



                           CSE Plot on Ch 78 between 30MHz ~ 3 GHz




                           CSE Plot on Ch 78 between 2 GHz ~ 25 GHz




TEL : 886-3-327-3456                                                  Page Number      : 48 of 58
FAX : 886-3-328-4978                                                  Issued Date      : Nov. 13, 2018
Report Template No.: BU5-FR15CBT Version 2.1                          Report Version   : 01


            FCC RADIO TEST REPORT                                                    Report No. : FR870418A

3.8 Radiated Band Edges and Spurious Emission Measurement
3.8.1 Limit of Radiated Band Edges and Spurious Emission
         In any 100 kHz bandwidth outside the intentional radiator frequency band, all harmonics/spurious
         must be at least 20 dB below the highest emission level within the authorized band. In addition,
         radiated emissions which fall in the restricted bands must also comply with the limits as below.
                     Frequency                       Field Strength               Measurement Distance
                        (MHz)                     (microvolts/meter)                          (meters)
                    0.009 – 0.490                     2400/F(kHz)                               300
                    0.490 – 1.705                     24000/F(kHz)                              30
                    1.705 – 30.0                           30                                   30
                       30 – 88                             100                                   3
                       88 – 216                            150                                   3
                      216 - 960                            200                                   3
                     Above 960                             500                                   3


3.8.2 Measuring Instruments
         See list of measuring equipment of this test report.




TEL : 886-3-327-3456                                                         Page Number             : 49 of 58
FAX : 886-3-328-4978                                                         Issued Date             : Nov. 13, 2018
Report Template No.: BU5-FR15CBT Version 2.1                                 Report Version          : 01


              FCC RADIO TEST REPORT                                                   Report No. : FR870418A

3.8.3 Test Procedures
         1.     The EUT was placed on a turntable with 0.8 meter for frequency below 1GHz and 1.5 meter for
                frequency above 1GHz respectively above ground.
         2.     The EUT was set 3 meters from the interference receiving antenna, which was mounted on the
                top of a variable height antenna tower.
         3.     For each suspected emission, the EUT was arranged to its worst case and then tune the
                Antenna tower (from 1 m to 4 m) and turntable (from 0 degree to 360 degrees) to find the
                maximum reading. A pre-amp and a high pass filter are used for the test in order to get better
                signal level to comply with the guidelines.
         4.     Set to the maximum power setting and enable the EUT transmit continuously.
         5.     Use the following spectrum analyzer settings:
                (1)   Span shall wide enough to fully capture the emission being measured;
                (2)   Set RBW=100 kHz for f < 1 GHz, RBW=1MHz for f>1GHz ; VBW  RBW; Sweep = auto;
                      Detector function = peak; Trace = max hold for peak
                (3)   For average measurement: use duty cycle correction factor method per 15.35(c).
                      Duty cycle = On time/100 milliseconds
                      On time = N1*L1+N2*L2+...+Nn-1*LNn-1+Nn*Ln
                      Where N1 is number of type 1 pulses, L1 is length of type 1 pulses, etc.
                      Average Emission Level = Peak Emission Level + 20*log(Duty cycle)
         6.     Corrected Reading: Antenna Factor + Cable Loss + Read Level - Preamp Factor = Level
         7.     For testing below 1GHz, if the emission level of the EUT in peak mode was 3 dB lower than the
                limit specified, then peak values of EUT will be reported, otherwise, the emissions will be
                repeated one by one using the CISPR quasi-peak method and reported.
         8.     For testing above 1GHz, the emission level of the EUT in peak mode was 20dB lower than
                average limit (that means the emission level in average mode also complies with the limit in
                average mode), then peak values of EUT will be reported, otherwise, the emissions will be
                measured in average mode again and reported.


        Note: The average levels were calculated from the peak level corrected with duty cycle correction
        factor (-24.76dB) derived from 20log (dwell time/100ms). This correction is only for signals that hop
        with the fundamental signal, such as band-edge and harmonic. Other spurious signals that are
        independent of the hopping signal would not use this correction.




TEL : 886-3-327-3456                                                          Page Number        : 50 of 58
FAX : 886-3-328-4978                                                          Issued Date        : Nov. 13, 2018
Report Template No.: BU5-FR15CBT Version 2.1                                  Report Version     : 01


            FCC RADIO TEST REPORT                            Report No. : FR870418A

3.8.4 Test Setup
         For radiated emissions below 30MHz




         For radiated emissions from 30MHz to 1GHz




TEL : 886-3-327-3456                                 Page Number      : 51 of 58
FAX : 886-3-328-4978                                 Issued Date      : Nov. 13, 2018
Report Template No.: BU5-FR15CBT Version 2.1         Report Version   : 01


            FCC RADIO TEST REPORT                                                 Report No. : FR870418A


         For radiated emissions above 1GHz




3.8.5 Test Results of Radiated Spurious Emissions (9 kHz ~ 30 MHz)
         The low frequency, which started from 9 kHz to 30MHz, was pre-scanned and the result which was
         20dB lower than the limit line was not reported.
         There is a comparison data of both open-field test site and alternative test site - semi-Anechoic
         chamber according to 414788 D01 Radiated Test Site v01r01, and the result came out very similar.


3.8.6 Test Result of Radiated Spurious at Band Edges
        Please refer to Appendix C and D.


3.8.7 Duty Cycle
        Please refer to Appendix E.


3.8.8 Test Result of Radiated Spurious Emission (30MHz ~ 10th Harmonic)
        Please refer to Appendix C and D.




TEL : 886-3-327-3456                                                      Page Number      : 52 of 58
FAX : 886-3-328-4978                                                      Issued Date      : Nov. 13, 2018
Report Template No.: BU5-FR15CBT Version 2.1                              Report Version   : 01


            FCC RADIO TEST REPORT                                                     Report No. : FR870418A

3.9 AC Conducted Emission Measurement
3.9.1 Limit of AC Conducted Emission
         For equipment that is designed to be connected to the public utility (AC) power line, the radio
         frequency voltage that is conducted back onto the AC power line on any frequency or frequencies
         within the band 150 kHz to 30 MHz shall not exceed the limits in the following table.

                                                                     Conducted limit (dBμV)
           Frequency of emission (MHz)
                                                        Quasi-peak                             Average

                        0.15-0.5                           66 to 56*                           56 to 46*
                          0.5-5                                 56                                46
                          5-30                                  60                                50
         *Decreases with the logarithm of the frequency.


3.9.2 Measuring Instruments
         See list of measuring equipment of this test report.


3.9.3 Test Procedures
         1. The EUT was placed 0.4 meter from the conducting wall of the shielding room was kept at least
              80 centimeters from any other grounded conducting surface.
         2. Connect EUT to the power mains through a line impedance stabilization network (LISN).
         3. All the support units are connecting to the other LISN.
         4. The LISN provides 50 ohm coupling impedance for the measuring instrument.
         5. The FCC states that a 50 ohm, 50 microhenry LISN should be used.
         6. Both sides of AC line were checked for maximum conducted interference.
         7. The frequency range from 150 kHz to 30 MHz was searched.
         8. Set the test-receiver system to Peak Detect Function and specified bandwidth (IF Bandwidth =
              9kHz) with Maximum Hold Mode. Then measurement is also conducted by Average Detector
              and Quasi-Peak Detector Function respectively.




TEL : 886-3-327-3456                                                          Page Number          : 53 of 58
FAX : 886-3-328-4978                                                          Issued Date          : Nov. 13, 2018
Report Template No.: BU5-FR15CBT Version 2.1                                  Report Version       : 01


            FCC RADIO TEST REPORT                      Report No. : FR870418A

3.9.4 Test Setup




3.9.5 Test Result of AC Conducted Emission
         Please refer to Appendix B.




TEL : 886-3-327-3456                           Page Number      : 54 of 58
FAX : 886-3-328-4978                           Issued Date      : Nov. 13, 2018
Report Template No.: BU5-FR15CBT Version 2.1   Report Version   : 01


            FCC RADIO TEST REPORT                                                  Report No. : FR870418A

3.10 Antenna Requirements
3.10.1 Standard Applicable
         If directional gain of transmitting antennas is greater than 6dBi, the power shall be reduced by the
         same level in dB comparing to gain minus 6dBi. The use of a permanently attached antenna or of an
         antenna that uses a unique coupling to the intentional radiator shall be considered sufficient to
         comply with the rule.


3.10.2 Antenna Anti-Replacement Construction
         An embedded-in antenna design is used.


3.10.3 Antenna Gain
         The antenna peak gain of EUT is less than 6 dBi. Therefore, it is not necessary to reduce maximum
         peak output power limit.




TEL : 886-3-327-3456                                                       Page Number       : 55 of 58
FAX : 886-3-328-4978                                                       Issued Date       : Nov. 13, 2018
Report Template No.: BU5-FR15CBT Version 2.1                               Report Version    : 01


                  FCC RADIO TEST REPORT                                                                 Report No. : FR870418A

   4        List of Measuring Equipment
                                                                                 Calibration
  Instrument      Manufacturer    Model No.      Serial No.   Characteristics                      Test Date     Due Date        Remark
                                                                                    Date
                                                                                                 Oct. 20, 2018~               Conducted
 Power Meter         Agilent       E4416A       GB41292344         N/A          Dec. 20, 2017                   Dec. 19, 2018
                                                                                                 Oct. 26, 2018                (TH05-HY)
                                                                                                 Oct. 20, 2018~               Conducted
 Power Sensor        Agilent       E9327A       US40441548 50MHz~18GHz Dec. 20, 2017                            Dec. 19, 2018
                                                                                                 Oct. 26, 2018                (TH05-HY)
                    Rohde &                                                                      Oct. 20, 2018~                 Conducted
Signal Analyzer                     FSV40         101397       10Hz~40GHz       Nov. 07, 2017                   Nov. 06, 2018
                    Schwarz                                                                      Oct. 26, 2018                  (TH05-HY)
BT Base Station     Rohde &                                                                      Oct. 20, 2018~                 Conducted
                                    CBT32         100519           N/A          May 30, 2018                    May 29, 2019
  (Measure)         Schwarz                                                                      Oct. 26, 2018                  (TH05-HY)
Switch Box & RF                                                                                  Oct. 20, 2018~               Conducted
                    Burgeon        ETF-058      EC1300484          N/A          Mar. 01, 2018                   Feb. 28, 2019
     Cable                                                                                       Oct. 26, 2018                (TH05-HY)
  AC Power                                                                                                                      Conduction
                    ChainTek      APC-1000W         N/A            N/A              N/A          Oct. 25, 2018      N/A
   Source                                                                                                                       (CO05-HY)
   EMI Test         Rohde &                                                                                                     Conduction
                                    ESR3          102388      9KHz~3.6GHz       Dec. 08, 2017 Oct. 25, 2018 Dec. 07, 2018
   Receiver         Schwarz                                                                                                     (CO05-HY)
                    Rohde &                                                                                                     Conduction
     LISN                          ENV216         100080       9kHz~30MHz       Nov. 30, 2017 Oct. 25, 2018 Nov. 29, 2018
                    Schwarz                                                                                                     (CO05-HY)
                    Rohde &                                                                                                     Conduction
   Software                      EMC32 V10.30       N/A            N/A              N/A          Oct. 25, 2018      N/A
                    Schwarz                                                                                                     (CO05-HY)
                   HUBER +                                                                                                      Conduction
   LF Cable                        RG-214/U        LF01            N/A          Jan. 03, 2018 Oct. 25, 2018 Jan. 02, 2019
                   SUHNER                                                                                                       (CO05-HY)
                    Rohde &                                                                                                     Conduction
 Pulse Limiter                     ESH3-Z2        100851           N/A          Jan. 03, 2018 Oct. 25, 2018 Jan. 02, 2019
                    Schwarz                                                                                                     (CO05-HY)




   TEL : 886-3-327-3456                                                                         Page Number         : 56 of 58
   FAX : 886-3-328-4978                                                                         Issued Date         : Nov. 13, 2018
   Report Template No.: BU5-FR15CBT Version 2.1                                                 Report Version      : 01


                FCC RADIO TEST REPORT                                                                     Report No. : FR870418A



                                                                                   Calibration
 Instrument     Manufacturer      Model No.        Serial No.   Characteristics                      Test Date      Due Date      Remark
                                                                                      Date
                                                                                                   Oct. 23, 2018~                 Radiation
    Filter       Microwave        H3G018G1         SN477219     3.0G High Pass Nov. 21, 2017                      Nov. 20, 2018
                                                                                                   Nov. 01, 2018                (03CH13-HY)
  EMI Test                                                         20Hz to                         Oct. 23, 2018~                 Radiation
                   Agilent      N9038A(MXE)       MY53290053                      Jan. 16, 2018                   Jan. 15, 2019
  Receiver                                                         26.5GHz                         Nov. 01, 2018                (03CH13-HY)
                  Rohde &                                                                          Oct. 23, 2018~                 Radiation
Loop Antenna                       HFH2-Z2           100315     9 kHz~30 MHz Nov. 10, 2017                        Nov. 09, 2018
                  Schwarz                                                                          Nov. 01, 2018                (03CH13-HY)
                                                                                                   Oct. 23, 2018~                 Radiation
    Filter       Wainwright     WLKS1200-8SS          SN3       1.2G Low Pass Nov. 21, 2017                       Nov. 20, 2018
                                                                                                   Nov. 01, 2018                (03CH13-HY)
                                                                18GHz~40GHz,
                                                                                            Oct. 23, 2018~                 Radiation
  Amplifier        MITEQ        TTA1840-35-HG       1871923      VSWR : 2.5:1 Jul. 16, 2018                Jul. 15, 2019
                                                                                            Nov. 01, 2018                (03CH13-HY)
                                                                    max
                Sonoma-Instru                                                                      Oct. 23, 2018~                 Radiation
  Amplifier                         310 N            187282      9KHz~1GHz        Dec. 21, 2016                   Dec. 20, 2018
                    ment                                                                           Nov. 01, 2018                (03CH13-HY)
                                     CBL
                                                                                                   Oct. 23, 2018~                 Radiation
Bilog Antenna      TESEQ        6111D&00800N1      40103&07     30MHz to 1GHz Jan. 10, 2018                       Jan. 09, 2019
                                                                                                   Nov. 01, 2018                (03CH13-HY)
                                   D01N-06
                SCHWARZBE                                                                          Oct. 23, 2018~                 Radiation
Horn Antenna                     BBHA 9120 D       9120D-1241   1GHz ~ 18GHz Jun. 29, 2018                        Jun. 28, 2019
                   CK                                                                              Nov. 01, 2018                (03CH13-HY)
                                AMF-7D-001018                                                      Oct. 23, 2018~                Radiation
 Preamplifier      MITEQ                            1590074     1GHz~18GHz        May 21, 2018                    May 20, 2019
                                  00-30-10P                                                        Nov. 01, 2018               (03CH13-HY)
                                                                                                   Oct. 23, 2018~                 Radiation
 Preamplifier     Keysight          83017A        MY53270147 1GHz~26.5GHz Feb. 02, 2018                           Feb. 01, 2019
                                                                                                   Nov. 01, 2018                (03CH13-HY)
  Spectrum                                                                                         Oct. 23, 2018~                 Radiation
                  Keysight         N9010A         MY55370526     10Hz~44GHz       Mar. 15, 2018                   Mar. 14, 2019
  Analyzer                                                                                         Nov. 01, 2018                (03CH13-HY)
                                                                                                   Oct. 23, 2018~                Radiation
Antenna Mast       EMEC         AM-BS-4500-B          N/A           1m~4m             N/A                             N/A
                                                                                                   Nov. 01, 2018               (03CH13-HY)
                                                                                                   Oct. 23, 2018~                Radiation
 Turn Table        EMEC             TT2000            N/A       0~360 Degree          N/A                             N/A
                                                                                                   Nov. 01, 2018               (03CH13-HY)
SHF-EHF Horn SCHWARZBE                                                                             Oct. 23, 2018~                 Radiation
                                  BBHA 9170       BBHA9170584 18GHz- 40GHz Nov. 27, 2017                          Nov. 26, 2018
  Antenna       CK                                                                                 Nov. 01, 2018                (03CH13-HY)
                                AMF-7D-001018                                                      Oct. 23, 2018~                 Radiation
 Preamplifier      MITEQ                            2025787     1GHZ~18GHZ Mar. 12, 2018                          Mar. 11, 2019
                                     00                                                            Nov. 01, 2018                (03CH13-HY)
                                                  171000180005                          Oct. 23, 2018~                 Radiation
 Preamplifier     Jet-Power     JPA0118-55-303                 1GHZ~18GHZ Apr. 16, 2018                Apr. 15, 2019
                                                      4001                              Nov. 01, 2018                (03CH13-HY)
                  HUBER +         SUCOFLEX                                                         Oct. 23, 2018~                 Radiation
  RF Cable                                         0030/126E       30M-18G        Jan. 22, 2018                   Jan. 21, 2019
                  SUHNER            126E                                                           Nov. 01, 2018                (03CH13-HY)
                  HUBER +                                                                          Oct. 23, 2018~                 Radiation
  RF Cable                      SUCOFLEX 104        335041/4       30M-18G        Jan. 22, 2018                   Jan. 21, 2019
                  SUHNER                                                                           Nov. 01, 2018                (03CH13-HY)
                  HUBER +                                                                          Oct. 23, 2018~                 Radiation
  RF Cable                      SUCOFLEX 104       MY24961/4     30M~18GHz        Jan. 22, 2018                   Jan. 21, 2019
                  SUHNER                                                                           Nov. 01, 2018                (03CH13-HY)
                  HUBER +                                                                          Oct. 23, 2018~                 Radiation
  RF Cable                      SUCOFLEX 102       MY2859/2      30M~40GHz        Mar. 14, 2018                   Mar. 13, 2019
                  SUHNER                                                                           Nov. 01, 2018                (03CH13-HY)
                  HUBER +                                                                          Oct. 23, 2018~                 Radiation
  RF Cable                      SUCOFLEX 102       MY4274/2      30M~40GHz        Mar. 14, 2018                   Mar. 13, 2019
                  SUHNER                                                                           Nov. 01, 2018                (03CH13-HY)
                                                                                                   Oct. 23, 2018~                Radiation
  Software         AUDIX        E3 6.2009-8-24c    RK-001124         N/A              N/A                             N/A
                                                                                                   Nov. 01, 2018               (03CH13-HY)




  TEL : 886-3-327-3456                                                                            Page Number         : 57 of 58
  FAX : 886-3-328-4978                                                                            Issued Date         : Nov. 13, 2018
  Report Template No.: BU5-FR15CBT Version 2.1                                                    Report Version      : 01


            FCC RADIO TEST REPORT                                         Report No. : FR870418A

5      Uncertainty of Evaluation
       Uncertainty of Conducted Emission Measurement (150 kHz ~ 30 MHz)
        Measuring Uncertainty for a Level of Confidence
                                                                           2.2
                     of 95% (U = 2Uc(y))


       Uncertainty of Radiated Emission Measurement (30 MHz ~ 1000 MHz)
        Measuring Uncertainty for a Level of Confidence
                                                                           4.9
                     of 95% (U = 2Uc(y))


       Uncertainty of Radiated Emission Measurement (1000 MHz ~ 18000 MHz)
        Measuring Uncertainty for a Level of Confidence
                                                                           5.4
                     of 95% (U = 2Uc(y))


       Uncertainty of Radiated Emission Measurement (18000 MHz ~ 40000 MHz)
        Measuring Uncertainty for a Level of Confidence
                                                                           4.3
                     of 95% (U = 2Uc(y))




TEL : 886-3-327-3456                                              Page Number      : 58 of 58
FAX : 886-3-328-4978                                              Issued Date      : Nov. 13, 2018
Report Template No.: BU5-FR15CBT Version 2.1                      Report Version   : 01


                                                                                                    Report Number : FR870418A

Appendix A. Test Result of Conducted Test Items

Test Engineer:                       Shiming Liu                         Temperature:                             21~25         °C
Test Date:                      2018/10/20~2018/10/26                    Relative Humidity:                       51~54         %

                                            TEST RESULTS DATA
                        20dB and 99% Occupied Bandwidth and Hopping Channel Separation

                                                                          Hopping Channel       Hopping Channel
                                                              99%
        Data                      Freq. 20db BW                             Separation            Separation
 Mod.        NTX         CH.                               Bandwidth                                               Pass/Fail
        Rate                     (MHz)   (MHz)                             Measurement           Measurement
                                                             (MHz)
                                                                               (MHz)              Limit (MHz)
  DH    1Mbps       1    0       2402       0.935            0.883              0.999               0.6233           Pass
  DH    1Mbps       1    39      2441       0.932            0.877              0.999               0.6213           Pass
  DH    1Mbps       1    78      2480       0.932            0.877              1.003               0.6213           Pass
 2DH    2Mbps       1    0       2402       1.259            1.161              0.964               0.8393           Pass
 2DH    2Mbps       1    39      2441       1.263            1.164              0.986               0.8423           Pass
 2DH    2Mbps       1    78      2480       1.263            1.164              0.933               0.8423           Pass
 3DH    3Mbps       1    0       2402       1.233            1.143              0.999               0.8220           Pass
 3DH    3Mbps       1    39      2441       1.233            1.149              1.012               0.8220           Pass
 3DH    3Mbps       1    78      2480       1.233            1.149              1.298               0.8220           Pass



                                                           TEST RESULTS DATA
                                                               Dwell Time


           Hopping
                               Hops Over        Package
           Channel                                                Dwell Time           Limits
 Mod.                          Occupancy        Transfer                                        Pass/Fail
           Number                                                   (sec)              (sec)
                               Time(hops)     Time (msec)
            Rate

Nomal          79                106.67             2.90               0.31             0.4       Pass
 AFH           20                53.33              2.90               0.15             0.4       Pass



                                                           TEST RESULTS DATA
                                                             Peak Power Table
                          Peak Power          Power Limit          Test
 DH      CH.     NTX
                            (dBm)               (dBm)             Result
         0          1       10.00               20.97             Pass
 DH1     39         1        9.68               20.97             Pass
         78         1        9.13               20.97             Pass
         0          1       10.20               20.97             Pass
2DH1     39         1        9.71               20.97             Pass
         78         1        9.20               20.97             Pass
         0          1       10.32               20.97             Pass
3DH1     39         1       10.01               20.97             Pass
         78         1        9.48               20.97             Pass



                                                           TEST RESULTS DATA
                                                           Average Power Table
                                                             (Reporting Only)

                         Average Power        Duty Factor
 DH      CH.     NTX
                             (dBm)               (dB)
         0          1         9.83               5.18
 DH1     39         1         9.51               5.18
         78         1         8.96               5.18
         0          1         7.80               5.08
2DH1     39         1         7.59               5.08
         78         1         7.03               5.08
         0          1         7.83               5.08
3DH1     39         1         7.60               5.08
         78         1         7.04               5.08



                                                       TEST RESULTS DATA
                                                    Number of Hopping Frequency

                                  Adaptive
 Number of Hopping               Frequency              Limits
                                                                           Pass/Fail
    (Channel)                     Hopping             (Channel)
                                 (Channel)
          79                         20                    > 15               Pass




                                                                                                                                     A1-1 of 1


 serovc«s. FCC RADIO TEST REPORT                        Report No. : FR870418A


Appendix B. AC Conducted Emission Test Results
                                        Temperature :          24~26°C
         Test Engineer : |Jimmy Chang        —       —
                                        Relative Humidity :    |50~52%




TEL : 886—3—327—3456                             Page Number       : B1 of B1
FAX : 886—3—328—4978


EUT Information
Report NO :                                            870418
Test Mode :                                            Mode 1
Test Voltage :                                         120Vac/60Hz
Phase :                                                Line


                                                                   F u ll S p e c tru m


                       100


                       90


                       80


                       70

                                                                                                        C IS P R -Q P L im it a t M a in P o rts
       Level in dBuV




                       60

                                                                                                    C IS P R -A v e L im it a t M a in P o rts
                       50


                       40


                       30


                       20


                       10


                        0
                        150k        3 0 0 4 0 05 0 0    8 0 01 M            2M      3M 4M 5M 6              8 10M           20M 30M
                                                                     F re q u e n c y in H z




Final_Result
  Frequency                  QuasiPeak     CAverage        Limit       Margin       Line       Filter       Corr.
    (MHz)                     (dBuV)        (dBuV)        (dBuV)        (dB)                                (dB)
      0.174750                       ---       29.42        54.73        25.31     L1      OFF               19.5
      0.174750                    44.60           ---       64.73        20.13     L1      OFF               19.5
      0.296250                       ---       25.74        50.35        24.61     L1      OFF               19.5
      0.296250                    33.28           ---       60.35        27.07     L1      OFF               19.5
      0.663000                       ---       24.91        46.00        21.09     L1      OFF               19.6
      0.663000                    30.56           ---       56.00        25.44     L1      OFF               19.6
      1.869000                       ---       23.84        46.00        22.16     L1      OFF               19.6
      1.869000                    26.34           ---       56.00        29.66     L1      OFF               19.6
      6.103500                       ---       27.81        50.00        22.19     L1      OFF               19.8
      6.103500                    33.59           ---       60.00        26.41     L1      OFF               19.8
     13.560000                       ---       28.98        50.00        21.02     L1      OFF               20.0
     13.560000                    54.99           ---       60.00         5.01     L1      OFF               20.0
     18.390750                       ---       31.20        50.00        18.80     L1      OFF               20.2
     18.390750                    37.72           ---       60.00        22.28     L1      OFF               20.2


EUT Information
Report NO :                                            870418
Test Mode :                                            Mode 1
Test Voltage :                                         120Vac/60Hz
Phase :                                                Neutral


                                                                   F u ll S p e c tru m


                       100


                       90


                       80


                       70

                                                                                                        C IS P R -Q P L im it a t M a in P o rts
       Level in dBuV




                       60

                                                                                                    C IS P R -A v e L im it a t M a in P o rts
                       50


                       40


                       30


                       20


                       10


                        0
                        150k        3 0 0 4 0 05 0 0    8 0 01 M            2M      3M 4M 5M 6              8 10M           20M 30M
                                                                     F re q u e n c y in H z




Final_Result
  Frequency                  QuasiPeak     CAverage        Limit       Margin       Line       Filter       Corr.
    (MHz)                     (dBuV)        (dBuV)        (dBuV)        (dB)                                (dB)
      0.172500                       ---       28.03        54.84        26.81     N       OFF               19.5
      0.172500                    42.80           ---       64.84        22.04     N       OFF               19.5
      0.399750                       ---       25.41        47.86        22.45     N       OFF               19.5
      0.399750                    32.74           ---       57.86        25.12     N       OFF               19.5
      1.113000                       ---       23.93        46.00        22.07     N       OFF               19.6
      1.113000                    27.84           ---       56.00        28.16     N       OFF               19.6
      2.793750                       ---       24.14        46.00        21.86     N       OFF               19.6
      2.793750                    25.99           ---       56.00        30.01     N       OFF               19.6
      5.894250                       ---       28.62        50.00        21.38     N       OFF               19.8
      5.894250                    34.58           ---       60.00        25.42     N       OFF               19.8
     13.560000                       ---       31.31        50.00        18.69     N       OFF               20.1
     13.560000                    51.13           ---       60.00         8.87     N       OFF               20.1
     18.098250                       ---       27.07        50.00        22.93     N       OFF               20.2
     18.098250                    30.89           ---       60.00        29.11     N       OFF               20.2


                   FCC RADIO TEST REPORT                                                     Report No. : FR870418A



      Appendix C. Radiated Spurious Emission
                                                                           Temperature :             24~25°C
Test Engineer :              Alex Jheng, Fu Chen, and Wilson Wu
                                                                           Relative Humidity :       48~50%


                                                     2.4GHz 2400~2483.5MHz
                                                       BT (Band Edge @ 3m)

    BT      Note   Frequency         Level     Over       Limit   Read    Antenna   Path     Preamp     Ant    Table Peak Pol.
                                              Limit     Line      Level   Factor    Loss     Factor     Pos     Pos Avg.
                     ( MHz )       ( dBμV/m ) ( dB ) ( dBμV/m ) ( dBμV ) ( dB/m )   ( dB )   ( dB )    ( cm ) ( deg ) (P/A) (H/V)
                    2375.205          43.43    -30.57      74     40.58    27.19    5.56      29.9      376    352     P     H

                    2375.205          18.67    -35.33      54       -        -        -          -       -       -     A     H

              *       2402            97.64      -          -     94.72    27.23    5.58     29.89      376    352     P     H

              *       2402            72.88      -          -       -        -        -          -       -       -     A     H

                                                                                                                             H
    BT
                                                                                                                             H
  CH00
                     2363.34          43.17    -30.83      74     40.4     27.14    5.54     29.91      129    270     P     V
 2402MHz
                     2363.34          18.41    -35.59      54       -        -        -          -       -       -     A     V

              *       2402            95.28      -          -     92.36    27.23    5.58     29.89      129    270     P     V

              *       2402            70.52      -          -       -        -        -          -       -       -     A     V

                                                                                                                             V

                                                                                                                             V

                     2352.84          43.42    -30.58      74     40.67    27.14    5.52     29.91      400    347     P     H

                     2352.84          18.66    -35.34      54       -        -        -          -       -       -     A     H

              *       2441            97.23      -          -     94.12    27.37    5.62     29.88      400    347     P     H

              *       2441            72.47      -          -       -        -        -          -       -       -     A     H

                     2493.84          44.42    -29.58      74     41.11    27.5     5.68     29.87      400    347     P     H
    BT
                     2493.84          19.66    -34.34      54       -        -        -          -       -       -     A     H
  CH 39
                     2368.8           44.16    -29.84      74     41.33    27.19    5.54      29.9      133    270     P     V
 2441MHz
                     2368.8           19.4     -34.6       54       -        -        -          -       -       -     A     V

              *       2441            95.14      -          -     92.03    27.37    5.62     29.88      133    270     P     V

              *       2441            70.38      -          -       -        -        -          -       -       -     A     V

                     2490.2           43.88    -30.12      74     40.58    27.5     5.68     29.88      133    270     P     V

                     2490.2           19.12    -34.88      54       -        -        -          -       -       -     A     V




      TEL : 886-3-327-3456                                                          Page Number         : C1 of C6
      FAX : 886-3-328-4978


                     FCC RADIO TEST REPORT                                                     Report No. : FR870418A




               *          2480         96.31        -          -        93.07   27.46   5.66   29.88   392    347   P   H

               *          2480         71.55        -          -          -       -      -        -     -       -   A   H

                        2483.72         44.5      -29.5       74        41.24   27.46   5.68   29.88   392    347   P   H

                        2483.72        19.74      -34.26      54          -       -      -        -     -       -   A   H

                                                                                                                        H
  BT
                                                                                                                        H
 CH 78
               *          2480         93.02        -          -        89.78   27.46   5.66   29.88   104    106   P   V
2480MHz
               *          2480         68.26        -          -          -       -      -        -     -       -   A   V

                        2496.28        44.04      -29.96      74        40.73   27.5    5.68   29.87   104    106   P   V

                        2496.28        19.28      -34.72      54          -       -      -        -     -       -   A   V

                                                                                                                        V

                                                                                                                        V

          1.       No other spurious found.
Remark
          2.       All results are PASS against Peak and Average limit line.




    TEL : 886-3-327-3456                                                                Page Number    : C2 of C6
    FAX : 886-3-328-4978


        seonton cas.   FCC RADIO TEST REPORT                                                       Report No. : FR870418A


                                                       2.A4GHz 2400~2483.5MHz
                                                             BT (Harmonic @ 3m)

  BT          Note     Frequency        Level     Over         Limit    Read    Antenna|   Path    |Preamp|    Ant   Table |Peak] Pol.
                                                  Limit         Line    Level    Factor    Loss    Factor     Pos     Pos   |Avg.
                         (MHz )      _|(dBpuV/im)| (dB) |(dBuV/m)|(dBuV)| (dB/im)|         (dB)     (dB )     |(cm)|( deg ) |(P/A)|(HV)
                          4804          35.03     —38.97        74      54.19    31.22      8.2     58.58      100      0     P     H

                          4804          10.27     43.73         54         —       —         —        —         —       —     A     H

                                                                                                                                    H

  BT
                                                                                                                                    H

 CH 00
                          4804          34.45      |—39.55      74      53.61    31.22      8.2     58.58      100      0     P     V
2402MHz
                          4804          9.69      —44.31        54         —       —         —        —         —       —     A     V

                                                                                                                                    V

                                                                                                                                    V

                          4882          36.76     —37.24        74      55.46    31.36     8.49     58.55      100      0     P     H

                          4882           12         42          54         —       —         —        —         —       —     A     H
                          73283         41.89     |—32.11       74       53.8    s6.22     10.68    58.81      100      0     P     H
  BT
                          7323          17.13     —36.87        54         —       —         —        —         —       —     A     H
 CH 39
                          4882          36.48     —37.52        74      55.18    31.36     8.49     58.55      100      0     P     V
2441MHz
                          4882          11.72     42.28         54         —       —         —        —         —       —     A     V

                          7323          42.64     —31.36        74      54.55    36.22     10.68    58.81      100      0     P     V

                          7323          17.88     —36.12        54         —       —         —        —         —       —     A     V

                          4960          35.99      |—38.01      74      54.18    31.53     8.79     58.51      100      0     P     H

                          4960          11.23     42.77         54         —       —         —        —         —       —     A     H

                          7440          42.75     —31.25        74      54.18    36.49     10.74    58.66      100      0     P     H
  BT
                          7440          17.99     —36.01        54         —       —         —        —         —       —     A     H
 CH 78
                          4960          36.15      |—37.85      74      54.34    31.53     8.79     58.51      100      0     P     V
2480MHz
                          4960          11.39     —42.61        54         —       —         —        —         —       —     A     V

                          7440          42.6      —31.4         74      54.03    36.49     10.74    58.66      100      0     P     V

                          7440          17.84     —36.16        54         —       —         —        —         —       —     A     V

             1.    No other spurious found.
Remark
             2.    All results are PASS against Peak and Average limit line.




       TEL : 886—3—327—3456                                                                Page Number         : C3 of C6
       FAX : 886—3—328—4978


        serovc«s. FCC RADIO TEST REPORT                                                        Report No. : FR870418A


                                                          Emission below 1GHz

                                                            24GHz BT (LF)

 BT          Note|   Frequency         Level      Over       Limit   Read    Antenna|   Path   |Preamp|   Ant    Table |Peak] Pol.
                                                  Limit      Line    Level    Factor    Loss   Factor     Pos     Pos   |Avg.
                       (MHz )       _|(dBuV/im)| (dB ) |(dBuV/m)| (dBuV)     (dB/m)|    (dB)    (dB )     |(cm)|(deg )|(P/A)|(HV)
                          30           24.83      ~15.17      40     32.06    24.39     0.72    32.34       —       —     P     H

                        37.29          24.91      ~15.09      40     35.69    20.73     0.82    32.33       —       —     P     H

                        54.03          21.74      —18.26      40     40.17    12.91     0.98    32.32       —       —     P     H

                         888           38.64      —7.36       46     37.67     29       3.54    31.57      100      0     P     H
                        894.3          36.97      —9.03       46     35.96    29.01     3.54    31.54       —       —     P     H
                        958.7          33.14      —12.86      46     29.33    31.07     3.71    30.97       —       —     P     H
                                                                                                                                H
                                                                                                                                H
                                                                                                                                H
                                                                                                                                H
                                                                                                                                H
24GHz
                                                                                                                                H
 BT
  LE                    33.24          34.03      5.97        40     42.49    23.11     0.77    32.34       —       —     P     V

                        63.48          31.21      —8.79       40     50.49    12.04     0.99    32.31       —       —     P     V

                        71.04          31.96      —8.04       40     50.45    12.65     1.17    32.31       —       —     P     V

                        885.9          40.15      5.85        46     39.2     28.99     3.54    31.58       —       —     P     V
                        894.3          41.19      —4.81       46     40.18    29.01     3.54    31.54      100      0     P     V

                        953.1          33.85      |—12.15     46     30.36    30.81     3.71    31.03       —       —     P     V
                                                                                                                                V

                                                                                                                                V

                                                                                                                                V

                                                                                                                                V

                                                                                                                                V

                                                                                                                                V

            1.   No other spurious found.
Remark
            2.   All results are PASS against limit line.




       TEL : 886—3—327—3456                                                             Page Number        : C4 of C6
       FAX : 886—3—328—4978


            FCC RADIO TEST REPORT                                                     Report No. : FR870418A



                                                   Note symbol

          Fundamental Frequency which can be ignored. However, the level of any unwanted emissions shall not
   *
          exceed the level of the fundamental frequency.

   !      Test result is over limit line.

 P/A      Peak or Average

 H/V      Horizontal or Vertical




TEL : 886-3-327-3456                                                           Page Number       : C5 of C6
FAX : 886-3-328-4978


                 FCC RADIO TEST REPORT                                                   Report No. : FR870418A



            A calculation example for radiated spurious emission is shown as below:


  BT      Note   Frequency     Level    Over     Limit     Read    Antenna      Path     Preamp    Ant   Table Peak Pol.
                                        Limit     Line      Level   Factor      Loss     Factor    Pos     Pos Avg.
                   ( MHz )   ( dBμV/m ) ( dB ) ( dBμV/m ) ( dBμV ) ( dB/m )     ( dB )   ( dB )   ( cm ) ( deg ) (P/A) (H/V)
  BT
                    2390       55.45    -18.55     74      54.51    32.22       4.58     35.86     103    308     P     H
 CH 00

2402MHz             2390       43.54    -10.46     54       42.6    32.22       4.58     35.86     103    308     A     H



    1. Path Loss(dB) = Cable loss(dB) + Filter loss(dB) + Attenuator loss(dB)
    2. Level(dBμV/m) =
    Antenna Factor(dB/m) + Path Loss(dB) + Read Level(dBμV) - Preamp Factor(dB)
    3. Over Limit(dB) = Level(dBμV/m) – Limit Line(dBμV/m)


    For Peak Limit @ 2390MHz:
    1. Level(dBμV/m)
    = Antenna Factor(dB/m) + Path Loss(dB) + Read Level(dBμV) - Preamp Factor(dB)
    = 32.22(dB/m) + 4.58(dB) + 54.51(dBμV) – 35.86 (dB)
    = 55.45 (dBμV/m)
    2. Over Limit(dB)
    = Level(dBμV/m) – Limit Line(dBμV/m)
    = 55.45(dBμV/m) – 74(dBμV/m)
    = -18.55(dB)


    For Average Limit @ 2390MHz:
    1. Level(dBμV/m)
    = Antenna Factor(dB/m) + Path Loss(dB) + Read Level(dBμV) - Preamp Factor(dB)
    = 32.22(dB/m) + 4.58(dB) + 42.6(dBμV) – 35.86 (dB)
    = 43.54 (dBμV/m)
    2. Over Limit(dB)
    = Level(dBμV/m) – Limit Line(dBμV/m)
    = 43.54(dBμV/m) – 54(dBμV/m)
    = -10.46(dB)


    Both peak and average measured complies with the limit line, so test result is “PASS”.



    TEL : 886-3-327-3456                                                        Page Number        : C6 of C6
    FAX : 886-3-328-4978


            FCC RADIO TEST REPORT                                             Report No. : FR870418A


Appendix D. Radiated Spurious Emission Plots
                                                              Temperature :         24.5~25°C
Test Engineer :        Alex Jheng, Fu Chen, and Wilson Wu
                                                              Relative Humidity : 48~50%


                                               Note symbol

   -L     Low channel location
   -R     High channel location




                                       2.4GHz 2400~2483.5MHz
                                        BT (Band Edge @ 3m)
               BT                     2.4GHz 2400~2483.5MHz Band Edge @ 3m

                                                 BT CH00 2402MHz

                                  Horizontal                       Fundamental




              Peak




TEL : 886-3-327-3456                                                  Page Number      : D1 of D10
FAX : 886-3-328-4978


            FCC RADIO TEST REPORT                                   Report No. : FR870418A



              BT             2.4GHz 2400~2483.5MHz Band Edge @ 3m

                                       BT CH00 2402MHz

                          Vertical                         Fundamental




             Peak




TEL : 886-3-327-3456                                         Page Number    : D2 of D10
FAX : 886-3-328-4978


            FCC RADIO TEST REPORT                                     Report No. : FR870418A



              BT              2.4GHz 2400~2483.5MHz Band Edge @ 3m

                                        BT CH39 2441MHz

                          Horizontal                        Fundamental




             Peak




             Peak                                            Left blank




TEL : 886-3-327-3456                                          Page Number     : D3 of D10
FAX : 886-3-328-4978


            FCC RADIO TEST REPORT                                    Report No. : FR870418A



              BT             2.4GHz 2400~2483.5MHz Band Edge @ 3m

                                       BT CH39 2441MHz

                          Vertical                         Fundamental




             Peak




             Peak                                           Left blank




TEL : 886-3-327-3456                                         Page Number     : D4 of D10
FAX : 886-3-328-4978


            FCC RADIO TEST REPORT                                    Report No. : FR870418A



              BT              2.4GHz 2400~2483.5MHz Band Edge @ 3m

                                        BT CH78 2480MHz

                          Horizontal                        Fundamental




             Peak




TEL : 886-3-327-3456                                          Page Number    : D5 of D10
FAX : 886-3-328-4978


            FCC RADIO TEST REPORT                                   Report No. : FR870418A



              BT             2.4GHz 2400~2483.5MHz Band Edge @ 3m

                                       BT CH78 2480MHz

                          Vertical                         Fundamental




             Peak




TEL : 886-3-327-3456                                         Page Number    : D6 of D10
FAX : 886-3-328-4978


            FCC RADIO TEST REPORT                                        Report No. : FR870418A

                               2.4GHz 2400~2483.5MHz
                                  BT (Harmonic @ 3m)
              BT               2.4GHz 2400~2483.5MHz Harmonic @ 3m

                                        BT CH00 2402MHz

                          Horizontal                          Vertical




             Peak

             Avg.




TEL : 886-3-327-3456                                           Page Number       : D7 of D10
FAX : 886-3-328-4978


            FCC RADIO TEST REPORT                                        Report No. : FR870418A



              BT               2.4GHz 2400~2483.5MHz Harmonic @ 3m

                                        BT CH39 2441MHz

                          Horizontal                          Vertical




             Peak

             Avg.




TEL : 886-3-327-3456                                           Page Number       : D8 of D10
FAX : 886-3-328-4978


            FCC RADIO TEST REPORT                                        Report No. : FR870418A



              BT               2.4GHz 2400~2483.5MHz Harmonic @ 3m

                                        BT CH78 2480MHz

                          Horizontal                          Vertical




             Peak

             Avg.




TEL : 886-3-327-3456                                           Page Number       : D9 of D10
FAX : 886-3-328-4978


            FCC RADIO TEST REPORT                                          Report No. : FR870418A

                                 Emission below 1GHz
                                       2.4GHz BT (LF)
              BT                        2.4GHz 2400~2483.5MHz

                                               BT LF

                          Horizontal                            Vertical




             QP /

             Peak




TEL : 886-3-327-3456                                            Page Number        : D10 of D10
FAX : 886-3-328-4978


                FCC RADIO TEST REPORT                                                   Report No. : FR870418A



Appendix E. Duty Cycle Plots
                                 3DH5 on time (One Pulse) Plot on Channel 39




                                   on time (Count Pulses) Plot on Channel 39




                       Note:
                       1. Worst case Duty cycle = on time/100 milliseconds = 2 * 2.89 / 100 = 5.78 %
                       2. Worst case Duty cycle correction factor = 20*log(Duty cycle) = -24.76 dB
                       3. 3DH5 has the highest duty cycle worst case and is reported.




TEL : 886-3-327-3456                                                          Page Number       : E1 of E2
FAX : 886-3-328-4978


                FCC RADIO TEST REPORT                                             Report No. : FR870418A



                       Duty Cycle Correction Factor Consideration for AFH mode:


Bluetooth normal hopping rate is 1600Hz and reduced to 800Hz in AFH mode; due to the reduced number of
hopping frequencies, with the same packet configuration the dwell time in each channel frequency within
100msec period is longer in AFH mode than normal mode.


In AFH mode, the minimum hopping frequencies are 20, to get the longest dwell time DH5 packet is observed;
the period to have DH5 packet completing one hopping sequence is


                                      2.89 ms x 20 channels = 57.8 ms


There cannot be 2 complete hopping sequences within 100ms period, considering the random hopping
behavior, maximum 2 hops can be possibly observed within the period. [100ms / 57.6ms ] = 2 hops


Thus, the maximum possible ON time:


                                            2.89 ms x 2 = 5.78 ms


Worst case Duty Cycle Correction factor, which is derived from the maximum possible ON time,


                                   20 x log(5.78 ms/100ms) = -24.76 dB




TEL : 886-3-327-3456                                                      Page Number       : E2 of E2
FAX : 886-3-328-4978



Document Created: 2019-03-21 22:57:00
Document Modified: 2019-03-21 22:57:00

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC