D1900V2 Calibration for Impedance and Return-loss

Equipment                              Dipole Antenna                                Model                                     D1900V2
                                       Schmid&Partner
Manufacture                                                                          Serial                                    5d169
                                       Engineering AG
Tested by                              Tomohisa Nakagawa

1. Test environment
Date                                    March 29, 2017
Ambient Temperature                     24.0 deg.C                                 Relative humidity                           45%RH

2. Equipment used

   Control No.                 Instrument                     Manufacturer                     Model No                 Serial No              Test Item       Calibration Date *
                                                                                                                                                                Interval(month)
      MOS-37          Digital thermometer              LKM electronic                     DTM3000                   -                         SAR              2016/07/28 * 12
      MPF-02          2mm Oval Flat Phantom            Schmid&Partner                     QDOVA001BB                1045                      SAR              2016/05/07 * 12
                                                       Engineering AG
     MOS-26           Thermo-Hygrometer                CUSTOM                             CTH-201                   A08Q29                    SAR              2016/04/19 * 12
   SSLM195-01         Tissue simulation liqud          Schmid&Partner                     SL AAM 195 BA             -                         SAR*Daily        Pre-Check
                      (1950MHz,body)                   Engineering AG                                                                         Check Target
                                                                                                                                              Value ±5%
   SSLH190-01         Tissue simulation liqud          Schmid&Partner                     SL AAH 190 AA             -                         SAR*Daily        Pre-Check
                      (1900MHz,head)                   Engineering AG                                                                         Check Target
                                                                                                                                              Value ±5%
     SSDA-08          Dipole Antenna                   Schmid&Partner                     D1900V2                   5d169                     SAR              2016/03/09 * 36
                                                       Engineering AG
      EST-63          Network Analyzer                 KEYSIGHT                           E5071C                    MY46523746                SAR              2017/02/03 * 12
      EST-64          Calibration Kit                  KEYSIGHT                           85032F                    MY53201709                SAR              2017/02/02 * 12


3. Test Result
                                                  Head                Head               Deviation          Deviation
Impeadance,Transformed to feed point   cal day    (real part) [Ω]     (img part) [jΩ]    (real part) [Ω]    (img part) [jΩ]    Tolerance            Result
Calibration (SPEAG)                     2016/3/19               53.20               4.20 -                  -                  -                    -
Calibration(ULJ)                        2017/3/29               54.96               5.57               1.76               1.37 +/-5Ω+/-5jΩ          Complied

                                                  Head               Deviation            Tolerance
Return loss                            cal day    [dB]               [dB]                 [+/-dB]          Result
Calibration (SPEAG)                     2016/3/19             -25.90 -                    -                -
Calibration(ULJ)                        2017/3/29             -23.13               2.77               5.18 Complied

                                                  Body                Body                Deviation          Deviation
Impeadance,Transformed to feed point   cal day    (real part) [Ω]     (img part) [jΩ]     (real part) [Ω]    (img part) [jΩ]    Tolerance           Result
Calibration (SPEAG)                     2016/3/19               49.00                5.80 -                  -                  -                   -
Calibration(ULJ)                        2017/3/29              50.454             5.7278                1.45              -0.07 +/-5Ω+/-5jΩ         Complied

                                                  Body               Deviation            Tolerance
Return loss                            cal day    [dB]               [dB]                 [+/-dB]          Result
Calibration (SPEAG)                     2016/3/19             -24.50 -                    -                -
Calibration(ULJ)                        2017/3/29            -27.314              -2.81                4.9 Complied


*Tolerance : According to the KDB450824D02




                                                                                                                                                    Page No. 9


Measurement Plots

<Head Liquid>




<Body Liquid>




                    Page No. 10


Calibration Certificate for D2600V2 – SN 1030




                                                Page No. 11


Page No. 12


Page No. 13


Page No. 14


Page No. 15


Page No. 16


Page No. 17


Page No. 18


D2600V2 Calibration for Impedance and Return-loss

Equipment                                Dipole Antenna                              Model                                  D2600V2
                                         Schmid&Partner
Manufacture                                                                          Serial                                 1030
                                         Engineering AG
Tested by                                Tomohisa Nakagawa

1. Test environment
Date                                      March 18, 2017
Ambient Temperature                       24.0 deg.C                              Relative humidity                         45%RH

2. Equipment used
  Control No.                 Instrument                     Manufacturer                    Model No              Serial No           Test Item     Calibration
                                                                                                                                                        Date *
                                                                                                                                                   Interval(month)
     MPF-03           2mm Oval Flat                    Schmid&Partner                  QDOVA001BB                 1203               SAR           2016/05/07 * 12
                      Phantom                          Engineering AG
    MOS-35            Digital thermometer              HANNA                           Checktemp 4                -                  SAR           2016/07/28 * 12
    MPF-04            2mm Oval Flat                    Schmid&Partner                  QDOVA001BB                 1207               SAR           2016/05/07 * 12
                      Phantom                          Engineering AG
  MMSL2450            Tissue simulation                Schmid&Partner                  MSL2450V2                 SL AA 245           SAR           Pre Check
                      liquid (Body)                    Engineering AG                                            BA
  MHSL2450            Tissue simulation                Schmid&Partner                  HSL2450V2                 SL AAH 245          SAR           Pre Check
                      liquid (Head)                    Engineering AG                                            BA
     EST-08           Calibration Kit                  Agilent                         85032B                    3217A12903          SAR           2016/05/04 * 12
     EST-30           Network Analyzer                 Agilent                         N5230A                    MY46400314          SAR           2016/08/26 * 12

3. Test Result
                                                Head               Head           Deviation        Deviation
Impeadance,Transformed to feed point cal day    (real part) [Ω] (img part) [jΩ] (real part) [Ω] (img part) [jΩ] Tolerance        Result
Calibration (SPEAG)                    2016/3/9              50.00          -5.00 -                -               -             -
Calibration(ULJ)                       2017/4/7              47.19          -5.05            -2.81           -0.05 +/-5Ω+/-5jΩ   Complied

                                                Head            Deviation      Tolerance
Return loss                          cal day    [dB]            [dB]           [+/-dB]           Result
Calibration (SPEAG)                    2016/3/9          -26.00 -              -                 -
Calibration(ULJ)                       2017/4/7          -24.52           1.48              5.20 Complied

                                                Body               Body           Deviation        Deviation
Impeadance,Transformed to feed point cal day    (real part) [Ω] (img part) [jΩ] (real part) [Ω] (img part) [jΩ] Tolerance        Result
Calibration (SPEAG)                    2016/3/9              45.60          -4.10 -                -               -             -
Calibration(ULJ)                       2017/4/7              43.56          -4.57            -2.04           -0.47 +/-5Ω+/-5jΩ   Complied

                                                Body            Deviation      Tolerance
Return loss                          cal day    [dB]            [dB]           [+/-dB]           Result
Calibration (SPEAG)                    2016/3/9          -24.10 -              -                 -
Calibration(ULJ)                       2017/4/7          -21.48           2.62              4.82 Complied


*Tolerance : According to the KDB450824D02