17.5 Calibration Certificate for D750V3

FCC ID: ACJ9TGWW16C

RF Exposure Info

Download: PDF
FCCID_3904960

17.5 Calibration Certificate for D750V3 – SN1058, D835V2 - SN 4d149, D1750V2 - SN 1089

Calibration Certificate for D750




                                                                                  Page No. 1


Page No. 2


Page No. 3


Page No. 4


Page No. 5


Page No. 6


D750V2 Calibration for Impedance and Return-loss

Equipment                      Dipole Antenna                   Model                     D835V2
                               Schmid&Partner
Manufacture                                                     Serial                    4d149
                               Engineering AG
Tested by                      Tomohisa Nakagawa

1. Test environment
Date                            May 8, 2016
Ambient Temperature             24.0 deg.C                     Relative humidity          45%RH

Date                            May 31, 2017
Ambient Temperature             23.0 deg.C                     Relative humidity          46%RH

2. Equipment used calibration at 2016
  Control No.          Instrument               Manufacturer         Model No       Serial No      Test Item   Calibration Date *
                                                                                                                Interval(month)
   EST-30       Network Analyzer           Agilent               N5230A            MY46400314     SAR          2015/08/27 * 12
   EST-30       Calibration Kit            Agilent               85056A            MY44300225     SAR          2015/08/27 * 12
   MOS-26       Thermo-Hygrometer          CUSTOM                CTH-201           A08Q29         SAR          2016/04/19 * 12
   MPF-02       2mm Oval Flat Phantom      Schmid&Partner        QDOVA001BB        1045           SAR          2016/05/07 * 12
                                           Engineering AG
 MPSAM-02       SAM Phantom                Schmid&Partner        QD000P40CB        1333           SAR          2016/05/07 * 12
                                           Engineering AG
 MMSL0750       Tissue simulation liquid   Schmid&Partner        MSL750V2          SL AAM 075     SAR          Pre Check
                (Body)                     Engineering AG                          AA
  MHSL0750      Tissue simulation liquid   Schmid&Partner        HSL750V2          SL AAH 075     SAR          Pre Check
                (Head)                     Engineering AG                          AA
  SAR room3                                                                                                    Daily check


Equipment used calibration at 2017

 Control No.           Instrument              Manufacturer          Model No       Serial No      Test Item     Calibration
                                                                                                                    Date *
                                                                                                               Interval(month)
  EST-30        Network Analyzer           Agilent               N5230A            MY46400314     SAR          2016/08/26 * 12
  EST-57        2.4mm Calibration Kit      Agilent               85056A            MY44300225     SAR          2016/08/30 * 12
  MOS-30        Thermo-Hygrometer          Custom                CTH-201           3001           SAR          2016/07/28 * 12
 MMSL0750       Tissue simulation          Schmid&Partner        MSL750V2          SL AAM 075     SAR          Pre Check
                liquid (Body)              Engineering AG                          AA
 MHSL0750       Tissue simulation          Schmid&Partner        HSL750V2          SL AAH 075     SAR          Pre Check
                liquid (Head)              Engineering AG                          AA
   MPF-02       2mm Oval Flat              Schmid&Partner        QDOVA001BB        1045           SAR          2014/04/14 * 12
                Phantom                    Engineering AG
 SAR room1                                                                                                     Daily check




                                                                                                        Page No. 7


3. Test Result
Impeadance,Transformed              Head             Head              Deviation       Deviation
to feed point          cal day      (real part) [Ω] (img part) [jΩ] (real part) [Ω]    (img part) [jΩ]      Tolerance     Result
Calibration (SPEAG)       2015/5/28            54.40             -0.90 -               -                    -             -
Calibration(ULJ)           2016/5/8            55.10             -0.69            0.70              0.22    +/-5Ω+/-5jΩ   Complied
Calibration(ULJ)          2017/5/31            55.64              1.38            1.24              2.28    +/-5Ω+/-5jΩ   Complied

                                       Head           Deviation      Tolerance
Return loss               cal day      [dB]           [dB]           [+/-dB]             Result
Calibration (SPEAG)          2015/5/28         -27.20 -              -                   -
Calibration(ULJ)              2016/5/8         -26.23           0.97                5.44 Complied
Calibration(ULJ)             2017/5/31         -25.20           2.00                5.44 Complied

Impeadance,Transformed              Body             Body              Deviation       Deviation
to feed point          cal day      (real part) [Ω] (img part) [jΩ] (real part) [Ω]    (img part) [jΩ]      Tolerance     Result
Calibration (SPEAG)       2015/5/28            48.90             -3.20 -               -                    -             -
Calibration(ULJ)           2016/5/8            51.24             -3.35            2.34              -0.15   +/-5Ω+/-5jΩ   Complied
Calibration(ULJ)          2017/5/31          51.106              -1.95            2.21               1.25   +/-5Ω+/-5jΩ   Complied

                                       Body           Deviation       Tolerance
Return loss               cal day      [dB]           [dB]            [+/-dB]            Result
Calibration (SPEAG)          2015/5/28         -29.39 -               -                  -
Calibration(ULJ)              2016/5/8         -29.05            0.34               5.88 Complied
Calibration(ULJ)             2017/5/31         -33.08           -4.03               5.88 Complied

*Tolerance : According to the KDB865664D01




                                                                                                                     Page No. 8


Measurement Plots 2016/5/8
<Head Liquid>




<Body Liquid>




                             Page No. 9


Measurement Plots 2017/5/31
<Head Liquid>




<Body Liquid>




                              Page No. 10


Calibration Certificate for D835V2 - SN 4d149




                                                Page No. 11


Page No. 12


Page No. 13


Page No. 14


Page No. 15


Page No. 16


Page No. 17


Page No. 18


D835V2 Calibration for Impedance and Return-loss

Equipment                              Dipole Antenna                                Model                                     D835V2
                                       Schmid&Partner
Manufacture                                                                          Serial                                    4d149
                                       Engineering AG
Tested by                              Tomohisa Nakagawa

1. Test environment
Date                                    March 29, 2017
Ambient Temperature                     24.0 deg.C                                 Relative humidity                           45%RH

2. Equipment used

   Control No.                 Instrument                     Manufacturer                     Model No               Serial No                Test Item       Calibration Date *
                                                                                                                                                                Interval(month)
      MOS-37          Digital thermometer              LKM electronic                     DTM3000                   -                         SAR              2016/07/28 * 12
      MPF-02          2mm Oval Flat Phantom            Schmid&Partner                     QDOVA001BB                1045                      SAR              2016/05/07 * 12
                                                       Engineering AG
     MOS-26           Thermo-Hygrometer                CUSTOM                             CTH-201                   A08Q29                    SAR              2016/04/19 * 12
     SSDA-04          Dipole Antenna                   Schmid&Partner                      D835V2                   4d149                     SAR(D835)        2016/03/08 * 12
                                                       Engineering AG
    MMSL0900          Tissue simulation liquid         Schmid&Partner                     MSL900V2                  SL AAM 090 CA             SAR*Daily        Pre Check
                      (Body)                           Engineering AG                                                                         Check Target
                                                                                                                                              Value ±5%
    MHSL0900          Tissue simulation liquid         Schmid&Partner                     HSL900V2                  SL AAH 090 BB             SAR*Daily        Pre Check
                      (Head)                           Engineering AG                                                                         Check Target
                                                                                                                                              Value ±5%
      EST-63          Network Analyzer                 KEYSIGHT                           E5071C                    MY46523746                SAR              2017/02/03 * 12
      EST-64          Calibration Kit                  KEYSIGHT                           85032F                    MY53201709                SAR              2017/02/02 * 12


3. Test Result
                                                  Head                Head                Deviation          Deviation
Impeadance,Transformed to feed point   cal day    (real part) [Ω]     (img part) [jΩ]     (real part) [Ω]    (img part) [jΩ]    Tolerance           Result
Calibration (SPEAG)                     2016/3/19               52.40               -4.10 -                  -                  -                   -
Calibration(ULJ)                        2017/3/29               53.28               -0.39               0.88               3.71 +/-5Ω+/-5jΩ         Complied

                                                  Head               Deviation            Tolerance
Return loss                            cal day    [dB]               [dB]                 [+/-dB]          Result
Calibration (SPEAG)                     2016/3/19             -26.70 -                    -                -
Calibration(ULJ)                        2017/3/29             -29.83              -3.13               5.34 Complied

                                                  Body                Body                Deviation          Deviation
Impeadance,Transformed to feed point   cal day    (real part) [Ω]     (img part) [jΩ]     (real part) [Ω]    (img part) [jΩ]    Tolerance           Result
Calibration (SPEAG)                     2016/3/19               48.30               -6.10 -                  -                  -                   -
Calibration(ULJ)                        2017/3/29              48.885            -4.5311                0.59               1.57 +/-5Ω+/-5jΩ         Complied

                                                  Body               Deviation            Tolerance
Return loss                            cal day    [dB]               [dB]                 [+/-dB]          Result
Calibration (SPEAG)                     2016/3/19             -23.80 -                    -                -
Calibration(ULJ)                        2017/3/29            -26.507              -2.71               4.76 Complied


*Tolerance : According to the KDB450824D02




                                                                                                                                                 Page No. 19


Measurement Plots

<Head Liquid>




<Body Liquid>




                    Page No. 20


Calibration Certificate for D1750V2 - SN 1089




                                                Page No. 21


Page No. 22


Page No. 23


Page No. 24


Page No. 25


Page No. 26


Page No. 27


Page No. 28


D1750V2 Calibration for Impedance and Return-loss

Equipment                              Dipole Antenna                       Model                               D1750V2
                                       Schmid&Partner
Manufacture                                                                 Serial                              1089
                                       Engineering AG
Tested by                              Tomohisa Nakagawa

1. Test environment
                                       March 27 and 28,
Date
                                       2017
Ambient Temperature                    24.0 deg.C                         Relative humidity                     50%RH

2. Equipment used

  Control No.                 Instrument                  Manufacturer              Model No              Serial No     Test Item     Calibration Date *
                                                                                                                                       Interval(month)
     MOS-37           Digital thermometer          LKM electronic             DTM3000                 -                SAR            2016/07/28 * 12
     MPF-02           2mm Oval Flat Phantom        Schmid&Partner             QDOVA001BB              1045             SAR            2016/05/07 * 12
                                                   Engineering AG
    MOS-26            Thermo-Hygrometer            CUSTOM                     CTH-201                 A08Q29           SAR            2016/04/19 * 12
    SSDA-06           Dipole Antenna               Schmid&Partner             D1750V2                 1089             SAR(D1750)     2016/03/11 * 12
                                                   Engineering AG
  SSLM175-01          Tissue simulation liqud      Schmid&Partner             SL AAM 175 AA           -                SAR*Daily      Pre-check
                      (1750MHz,body)               Engineering AG                                                      Check Target
                                                                                                                       Value ±5%
   SSLH175-01         Tissue simulation liqud      Schmid&Partner             SL AAH 175 AA           -                SAR*Daily      Pre-check
                      (1750MHz,head)               Engineering AG                                                      Check Target
                                                                                                                       Value ±5%
     EST-63           Network Analyzer             KEYSIGHT                   E5071C                  MY46523746       SAR            2017/02/03 * 12
     EST-64           Calibration Kit              KEYSIGHT                   85032F                  MY53201709       SAR            2017/02/02 * 12


3. Test Result
                                               Head               Head           Deviation       Deviation
Impeadance,Transformed to feed point cal day   (real part) [Ω] (img part) [jΩ] (real part) [Ω] (img part) [jΩ] Tolerance         Result
Calibration (SPEAG)                  2016/3/11              48.90          -2.00 -               -               -               -
Calibration(ULJ)                     2017/3/28              49.16          -1.69            0.26            0.31 +/-5Ω+/-5jΩ     Complied

                                                   Head            Deviation       Tolerance
Return loss                              cal day   [dB]            [dB]            [+/-dB]          Result
Calibration (SPEAG)                      2016/3/11          -32.60 -               -                -
Calibration(ULJ)                         2017/3/28          -34.69           -2.09             6.52 Complied

                                               Body               Body           Deviation        Deviation
Impeadance,Transformed to feed point cal day   (real part) [Ω] (img part) [jΩ] (real part) [Ω] (img part) [jΩ] Tolerance         Result
Calibration (SPEAG)                  2016/3/11              46.10          -2.00 -                -              -               -
Calibration(ULJ)                     2017/3/27            45.959       0.22943              -0.14           2.23 +/-5Ω+/-5jΩ     Complied

                                                   Body            Deviation       Tolerance
Return loss                              cal day   [dB]            [dB]            [+/-dB]          Result
Calibration (SPEAG)                      2016/3/11          -26.70 -               -                -
Calibration(ULJ)                         2017/3/27         -28.299           -1.60             5.34 Complied


*Tolerance : According to the KDB450824D02




                                                                                                                          Page No. 29


Measurement Plots

<Head Liquid>




<Body Liquid>




                    Page No. 30



Document Created: 2018-06-13 11:40:17
Document Modified: 2018-06-13 11:40:17