03 FCC Test Report_15B

FCC ID: ACJ932IM2035BB

Test Report

Download: PDF
FCCID_4214311

                                                                                 Test report No.        : 12541477H-B-R1
                                                                                 Page                   : 1 of 14
                                                                                 Issued date            : March 22, 2019
                                                                                 FCC ID                 : ACJ932IM2035BB




                                  EMI TEST REPORT
                                Test Report No. : 12541477H-B-R1
        Applicant                             :     Panasonic Corporation of North America

        Type of Equipment                     :     WAM MID

        Model No.                             :     IM2035BB

        FCC ID                                :     ACJ932IM2035BB

        Test regulation                       :     FCC Part 15 Subpart B: 2018

        Test Result                           :     Complied (Refer to SECTION 3.2)
           1.   This test report shall not be reproduced in full or partial, without the written approval of UL Japan, Inc.
           2.   The results in this report apply only to the sample tested.
           3.   This sample tested is in compliance with the above regulation.
           4.   The test results in this report are traceable to the national or international standards.
           5.   This test report covers EMC technical requirements. It does not cover administrative issues
                such as Manual or non-EMC test related Requirements. (if applicable)
           6.   The all test items in this test report are conducted by UL Japan, Inc. Ise EMC Lab.
           7.   This test report must not be used by the customer to claim product certification, approval, or
                endorsement by NVLAP, NIST, or any agency of the Federal Government.
           8.   The information provided from the customer for this report is identified in SECTION 1.
           9.   This report is a revised version of 12541477H-B. 12541477H-B is replaced with this report.

                         Date of test:                           January 24, 2019

                         Representative test
                         engineer:
                                                             Toshifumi Yoneshige
                                                                   Engineer
                                                         Consumer Technology Division


                         Approved by:
                                                              Shinichi Miyazono
                                                                   Engineer
                                                         Consumer Technology Division


                                                            This laboratory is accredited by the NVLAP LAB CODE
                                                            200572-0, U.S.A. The tests reported herein have been
                                                            performed in accordance with its terms of accreditation.
                                                            *As for the range of Accreditation in NVLAP, you may
                                                            refer to the WEB address,
                                                            http://japan.ul.com/resources/emc_accredited/

       NVLAP LAB CODE: 200572-0

    The testing in which "Non-accreditation" is displayed is outside the accreditation scopes in UL Japan.
    There is no testing item of "Non-accreditation".

UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124                                                      Report Cover Page - 13-EM-F0429 Issue # 14.0


                                                                      Test report No.     : 12541477H-B-R1
                                                                      Page                : 2 of 14
                                                                      Issued date         : March 22, 2019
                                                                      FCC ID              : ACJ932IM2035BB




                                   REVISION HISTORY
                             Original Test Report No.: 12541477H-B

Revision       Test report No.        Date             Page revised   Contents
-              12541477H-B            February 13,     -              -
(Original)                            2019
1              12541477H-B-R1         March 22, 2019   P.7            Correction of erroneous description of
                                                                      configuration diagram in Clause 4.2;
                                                                      From “G” to “F”




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                                              Test report No.            : 12541477H-B-R1
                                                                                              Page                       : 3 of 14
                                                                                              Issued date                : March 22, 2019
                                                                                              FCC ID                     : ACJ932IM2035BB


CONTENTS                                                                                                                               PAGE

SECTION 1: Customer information ...................................................................................................... 4
SECTION 2: Equipment under test (E.U.T.) ......................................................................................... 4
SECTION 3: Test specification, procedures & results ......................................................................... 5
SECTION 4: Operation of E.U.T. during testing .................................................................................. 7
SECTION 5: Radiated Emission ............................................................................................................. 8
APPENDIX 1: Test data .......................................................................................................................... 9
    Radiated emission ............................................................................................................................... 9
APPENDIX 2: Test instruments ........................................................................................................... 11
APPENDIX 3: Photographs of test setup ............................................................................................. 12
    Radiated Emission ............................................................................................................................ 12
    Worst Case Position (Horizontal: X-axis / Vertical: X-axis) ............................................................ 14




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                         Test report No.     : 12541477H-B-R1
                                                                         Page                : 4 of 14
                                                                         Issued date         : March 22, 2019
                                                                         FCC ID              : ACJ932IM2035BB


SECTION 1:         Customer information
Company Name                         :       Panasonic Corporation of North America*1)
Address                              :       Two Riverfront Plaza, 9th Floor Newark, NJ 07102-5490
Telephone Number                     :       +1-201-348-7760
Facsimile Number                     :       +1-201-348-7760
Contact Person                       :       Ben Botros

*1) Panasonic Corporation of North America designates Panasonic Automotive Systems Asia Pacific Co.,Ltd
     as manufacturer of the product (WAM MID).

The information provided from the customer is as follows;
- Applicant, Type of Equipment, Model No. on the cover and other relevant pages
- SECTION 1: Customer information
- SECTION 2: Equipment under test (E.U.T.)
- SECTION 4: Operation of E.U.T. during testing
* The laboratory is exempted from liability of any test results affected from the information in SECTION 2 and 4.



SECTION 2:         Equipment under test (E.U.T.)
2.1       Identification of E.U.T.

Type of Equipment                    :       WAM MID
Model No.                            :       IM2035BB
Serial No.                           :       Refer to Section 4, Clause 4.2
Rating                               :       DC 12.0 V
Receipt Date of Sample               :       December 27, 2018
(Information from test lab.)
Country of Mass-production           :       Thailand
Condition of EUT                     :       Production prototype
                                             (Not for Sale: This sample is equivalent to mass-produced items.)
Modification of EUT                  :       No Modification by the test lab


2.2       Product Description

Model: IM2035BB (referred to as the EUT in this report) is a WAM MID.

Radio Specification
[Transmitter]
 Radio Type                          :       Transmitter
 Frequency of Operation              :       125 kHz
 Modulation                          :       ASK
 Antenna type                        :       Air core coil inductive antenna
 Clock frequency (Maximum)           :       4 MHz

[Receiver]
 Radio Type                          :       Receiver
 Frequency of Operation              :       433.92 MHz

FCC15.111(b)
The receiving antenna (of this EUT) is installed inside the EUT and cannot be removed (permanently attached).
Therefore, Radiated emission test was performed.




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                                   Test report No.         : 12541477H-B-R1
                                                                                   Page                    : 5 of 14
                                                                                   Issued date             : March 22, 2019
                                                                                   FCC ID                  : ACJ932IM2035BB


SECTION 3:            Test specification, procedures & results

3.1          Test Specification

Test Specification                :     FCC Part 15 Subpart B
                                        FCC Part 15 final revised on March 12, 2018 and effective April 11, 2018

Title                             :     FCC 47CFR Part15 Radio Frequency Device
                                        Subpart B Unintentional Radiators


3.2          Procedures and results

 Item           Test Procedure               Limits                       Deviation Worst margin            Result           Remarks
                FCC: ANSI C63.4: 2014
                7. AC power - line           FCC:Part 15 Subpart B
 Conducted
                conducted emission           15.107(a)                    N/A           N/A                 N/A              *1)
 emission
                measurements
                IC: RSS-Gen 8.8              IC: RSS-Gen 8.8
                FCC: ANSI C63.4: 2014
                                             FCC: Part 15 Subpart B                     23.1 dB
 Radiated       8. Radiated                                                                                 Complied
                                             15.109(a)                    N/A           49.146 MHz                           -
 emission       emission measurements                                                                       a)
                                                                                        Vertical, QP
                IC: RSS-Gen 7                IC: RSS-Gen 7.1.2
 *Note: UL Japan, Inc’s EMI Work Procedure 13-EM-W0420.
 *1) The test is not applicable since the EUT is not the device that is designed to be connected to the public utility (AC) power line.

 a) Refer to APPENDIX 1 (data of Radiated emission)
 Symbols:
  Complied           The data of this test item has enough margin, more than the measurement uncertainty.
  Complied#          The data of this test item meets the limits unless the measurement uncertainty is taken into consideration.


3.3          Addition to standard

No addition, exclusion nor deviation has been made from the standard.


3.4          Uncertainty

There is no applicable rule of uncertainty in this applied standard. Therefore, the following results are derived
depending on whether or not laboratory uncertainty is applied.

EMI
The following uncertainties have been calculated to provide a confidence level of 95 % using a coverage factor k = 2.

                                               Radiated emission (Below 1 GHz)
        Polarity                   (3 m*)(+/-)                                 (10 m*)(+/-)
                    30 MHz to 200 MHz    200 MHz to 1000 MHz    30 MHz to 200 MHz    200 MHz to 1000 MHz
      Horizontal         4.8 dB                5.2 dB                  4.8 dB               5.0 dB
       Vertical          5.0 dB                6.3 dB                  4.9 dB               5.0 dB

                                              Radiated emission (Above 1 GHz)
                 (3 m*)(+/-)                                      (1 m*)(+/-)                              (10 m*)(+/-)
    1 GHz to 6 GHz      6 GHz to 18 GHz         10 GHz to 26.5 GHz      26.5 GHz to 40 GHz               1 GHz to 18 GHz
         5.0 dB              5.3 dB                    5.8 dB                 5.8 dB                          5.2 dB
* Measurement distance




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                               Test report No.         : 12541477H-B-R1
                                                                               Page                    : 6 of 14
                                                                               Issued date             : March 22, 2019
                                                                               FCC ID                  : ACJ932IM2035BB


3.5         Test Location

UL Japan, Inc. Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone: +81 596 24 8999, Facsimile: +81 596 24 8124
NVLAP Lab. code: 200572-0 / FCC Test Firm Registration Number: 199967
                                                                                                                    Maximum
                     IC Registration Width x Depth x      Size of reference ground plane (m)
Test site                                                                                    Other rooms            measuremen
                     Number          Height (m)           / horizontal conducting plane
                                                                                                                    t distance
No.1 semi-anechoic                                                                               No.1 Power
                     2973C-1         19.2 x 11.2 x 7.7    7.0 x 6.0                                                 10 m
chamber                                                                                          source room
No.2 semi-anechoic
                     2973C-2         7.5 x 5.8 x 5.2      4.0 x 4.0                              -                  3m
chamber
No.3 semi-anechoic                                                                               No.3 Preparation
                     2973C-3         12.0 x 8.5 x 5.9     6.8 x 5.75                                                3m
chamber                                                                                          room
No.3 shielded room   -               4.0 x 6.0 x 2.7      N/A                                    -                  -
No.4 semi-anechoic                                                                               No.4 Preparation
                     2973C-4         12.0 x 8.5 x 5.9     6.8 x 5.75                                                3m
chamber                                                                                          room
No.4 shielded room   -               4.0 x 6.0 x 2.7      N/A                                    -                  -
No.5 semi-anechoic
                     -               6.0 x 6.0 x 3.9      6.0 x 6.0                              -                  -
chamber
No.6 shielded room   -               4.0 x 4.5 x 2.7      4.0 x 4.5                              -                  -
No.6 measurement
                     -               4.75 x 5.4 x 3.0     4.75 x 4.15                            -                  -
room
No.7 shielded room   -               4.7 x 7.5 x 2.7      4.7 x 7.5                              -                  -
No.8 measurement
                     -               3.1 x 5.0 x 2.7      3.1 x 5.0                              -                  -
room
No.9 measurement
                     -               8.8 x 4.6 x 2.8      2.4 x 2.4                              -                  -
room
No.11 measurement
                     -               6.2 x 4.7 x 3.0      4.8 x 4.6                              -                  -
room
* Size of vertical conducting plane (for Conducted Emission test) : 2.0 m x 2.0 m for No.1, No.2, No.3, and No.4
semi-anechoic chambers and No.3 and No.4 shielded rooms.



3.6         Test data, Test instruments, and Test set up

Refer to APPENDIX.




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                            Test report No.        : 12541477H-B-R1
                                                                            Page                   : 7 of 14
                                                                            Issued date            : March 22, 2019
                                                                            FCC ID                 : ACJ932IM2035BB


SECTION 4:            Operation of E.U.T. during testing
4.1       Operating Mode(s)

Mode                                                                 Remarks
1) Normal Keyless Operation Mode                                     -
*The test signal level was confirmed to be sufficient to stabilize the local oscillator of the EUT.
* It was confirmed by using checker that the EUT receives the signal from the transmitter (pair of EUT).


4.2       Configuration and peripherals



                                         B      1              2                  D           4    E
                                                                              5



                                                      A                 3
                                   C
                                                                    F


                                                                        5



                                                              AC 100V/60Hz

        * Cabling and setup were taken into consideration and test data was taken under worse case conditions.
                                        *Item No. A includes Receiver Antenna.

Description of EUT and Support equipment
 No. Item                Model number Serial number                Manufacturer                             Remark
 A     WAM MID              IM2035BB         500017-0 180918       Panasonic Automotive Systems             EUT
                                                                   Asia Pacific Co.,Ltd
 B     Immobilizer          898394787Y       002                   TOKAI RIKA CO., LTD                      -
 C     RKE TXE              IK3600F          37                    Panasonic Automotive Systems             -
                                                                   Asia Pacific Co.,Ltd
 D     Jig             -                     -                     -                                        -
 E     SW/LED Box      -                     -                     -                                        -
 F     DC Power Supply PAK35-10A             LF002313              KIKUSUI                                  -

List of cables used
 No. Name                       Length (m)                                  Shield                     Remark
                                                             Cable                    Connector
  1    Signal Cable1            2.0                        Unshielded                 Unshielded       -
  2    Signal Cable2            1.0                        Unshielded                 Unshielded       -
  3    DC power Cable           1.0                        Unshielded                 Unshielded       -
  4    Signal Cable             0.8                        Unshielded                 Unshielded       -
  5    AC power Cable           1.8                        Unshielded                 Unshielded       -




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                         Test report No.      : 12541477H-B-R1
                                                                         Page                 : 8 of 14
                                                                         Issued date          : March 22, 2019
                                                                         FCC ID               : ACJ932IM2035BB


SECTION 5:           Radiated Emission
5.1    Operating environment

Test place           : No.4 semi anechoic chamber
Temperature          : See data
Humidity             : See data


5.2    Test configuration

EUT was placed on a urethane platform of nominal size, 1.0 m by 1.5 m, raised 0.8 m above the conducting ground
plane.
The EUT was set on the edge of the tabletop.
Test was made with the antenna positioned in both the horizontal and vertical planes of polarization. The measurement
antenna was varied in height above the conducting ground plane to obtain the maximum signal strength.
Photographs of the set up are shown in Appendix 3.


5.3    Test conditions

Frequency range          :   30 MHz - 200 MHz (Biconical antenna) / 200 MHz - 1000 MHz (Logperiodic antenna)
                             1000 MHz - 2000 MHz (Horn antenna)
Test distance            :   3m
EUT position             :   Table top
EUT operation mode       :   See Clause 4.1


5.4    Test procedure

The height of the measuring antenna varied between 1 and 4 m and EUT was rotated a full revolution in order to obtain
the maximum value of the electric field intensity.
The measurements were performed for both vertical and horizontal antenna polarization with the Test Receiver, or the
Spectrum Analyzer.
The radiated emission measurements were made with the following detector function of the Test Receiver and the
Spectrum Analyzer.

   Frequency            Below 1GHz                     Above 1GHz *1)
   Instrument used      Test Receiver                  Test Receiver
   IF Bandwidth         QP: BW 120 kHz                 PK: BW 1 MHz, CISPR AV: BW 1 MHz
*1) The measurement data was adjusted to a 3 m distance using the following Distance Factor.
    Distance Factor: 20 x log (3.6 m / 3 m) = 1.59 dB

- The noise levels were confirmed at each position of X, Y and Z axes of EUT to see the position of maximum noise, and the
test was made at the position that has the maximum noise.


5.5    Test result

Summary of the test results: Pass

The limit is rounded down to one decimal place.
The test result is rounded off to one or two decimal places, so some differences might be observed.


Date: January 24, 2019                    Test engineer: Toshifumi Yoneshige



UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                                                           Test report No.                 : 12541477H-B-R1
                                                                                                           Page                            : 9 of 14
                                                                                                           Issued date                     : March 22, 2019
                                                                                                           FCC ID                          : ACJ932IM2035BB


APPENDIX 1: Test data

                                                                   Radiated emission

             Report No.                                   12541477H
             Test place                                   Ise EMC Lab.
             Semi Anechoic Chamber                        No.4
             Date                                         January 24, 2019
             Temperature / Humidity                       24 deg. C / 41 % RH
             Engineer                                     Toshifumi Yoneshige
                                                          (Below 1 GHz)
             Mode                                         Mode 1

                 LIMIT : FCC15.109(a) 3m, below 1GHz:QP, above 1GHz:PK
                         All other spurious emissions were less than 20dB for the limit.                                                     Horizontal
                                                                                                                                             Vertical
                                                                                                                                             Horizontal
                     [dBuV/m]           << QP DATA >>                                                                                        Vertical
                80

                70

                60

                50

                40

                30

                20

                10

                 0
                  30M                 50M           70M          100M                     200M             300M                500M       700M        1G
                                                                                                                                          Frequency[Hz]



                                                      Antenna     Loss&
                      Frequency     Reading                                  Level      Angle    Height             Limit      Margin
                                              DET      Factor      Gain                                   Polar.                         Comment
                        [MHz]       [dBuV]             [dB/m]      [dB]     [dBuV/m]    [Deg]    [cm]              [dBuV/m]     [dB]
                           30.681      22.4   QP          18.1      -24.9        15.6      359      100   Vert.         40.0      24.4
                           49.146      30.1   QP          11.4      -24.6        16.9       35      100   Vert.         40.0      23.1
                           65.520      34.1   QP           7.0      -24.3        16.8       41      100   Vert.         40.0      23.2
                           80.080      32.6   QP           6.4      -24.1        14.9      271      100   Vert.         40.0      25.1
                          310.624      21.9   QP          14.0      -22.0        13.9      359      100   Vert.         46.0      32.1
                          309.273      22.0   QP          13.9      -22.0        13.9      359      150   Hori.         46.0      32.1




CHART: WITH FACTOR
ANT TYPE: - 30 MHz: LOOP, 30 MHz - 200 MHz: BICONICAL, 200 MHz - 1000 MHz: LOGPERIODIC, 1000 MHz -: HORN
CALCULATION: RESULT = READING + ANT FACTOR + LOSS & GAIN (CABLE + ATT - GAIN(AMP))




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                                                             Test report No.                : 12541477H-B-R1
                                                                                                             Page                           : 10 of 14
                                                                                                             Issued date                    : March 22, 2019
                                                                                                             FCC ID                         : ACJ932IM2035BB


                                                                   Radiated emission

             Report No.                                 12541477H
             Test place                                 Ise EMC Lab.
             Semi Anechoic Chamber                      No.4
             Date                                       January 24, 2019
             Temperature / Humidity                     24 deg. C / 41 % RH
             Engineer                                   Toshifumi Yoneshige
                                                        (Above 1 GHz)
             Mode                                       Mode 1

                 LIMIT : FCC15.109(a) 3m, below 1GHz:QP, above 1GHz:PK
                         FCC15.109(a) 3m, below 1GHz:QP, above 1GHz:AV                                                                        Horizontal
                                                                                                                                              Vertical
                                                                                                                                              Horizontal
                      [dBuV/m]              << AV/PEAK DATA >>                                                                                Vertical
               110
               100

                90

                80

                70

                60

                50
                40

                30

                20

                10

                 0
                     1G                                                                                                                                2G
                                                                                                                                           Frequency[Hz]



                                                        Antenna    Loss&
                          Frequency     Reading                               Level      Angle     Height             Limit      Margin
                                                  DET    Factor     Gain                                    Polar.                        Comment
                            [MHz]       [dBuV]           [dB/m]     [dB]     [dBuV/m]    [Deg]     [cm]              [dBuV/m]    [dB]
                             1522.041      43.8   PK        25.3     -28.8        40.3      359       100   Vert.         73.9     33.6
                             1522.041      29.5   AV        25.3     -28.8        26.0      359       100   Vert.         53.9     27.9
                             1525.154      29.5   AV        25.3     -28.8        26.0         0      100   Hori.         53.9     27.9
                             1525.154      43.4   PK        25.3     -28.8        39.9         0      100   Hori.         73.9     34.1




CHART: WITH FACTOR
ANT TYPE: - 30 MHz: LOOP, 30 MHz - 200 MHz: BICONICAL, 200 MHz - 1000 MHz: LOGPERIODIC, 1000 MHz -: HORN
CALCULATION: RESULT = READING + ANT FACTOR + LOSS & GAIN (CABLE - GAIN(AMP) + D-factor)




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                               Test report No.           : 12541477H-B-R1
                                                                               Page                      : 11 of 14
                                                                               Issued date               : March 22, 2019
                                                                               FCC ID                    : ACJ932IM2035BB


APPENDIX 2: Test instruments
Test Instruments
Test   LIMS ID Description                Manufacturer      Model           Serial               Last          Calibration   Cal Int
Item                                                                                             Calibration   Due Date
                                                                                                 Date
RE     148898   Attenuator                KEYSIGHT          8491A           MY52462282           10/03/2018    10/31/2019    12
RE     142227   Measure                   KOMELON           KMC-36          -                    -             -             -
RE     141152   EMI measurement program   TSJ               TEPTO-DV        -                    -             -             -
RE     141899   Spectrum Analyzer         AGILENT           E4448A          MY46180655           08/10/2018    08/31/2019    12
RE     141562   Thermo-Hygrometer         CUSTOM            CTH-201         0010                 01/11/2019    01/31/2020    12
RE     142011   AC4_Semi Anechoic         TDK               Semi Anechoic   DA-10005             06/28/2018    06/30/2020    24
                Chamber(NSA)                                Chamber 3m
RE     141412   Microwave Cable           Junkosha          MWX221          1305S002R(1m) / 06/14/2018         06/30/2019    12
                                                                            1405S146(5m)
RE     141581   MicroWave System          AGILENT           83017A          650             10/04/2018         10/31/2019    12
                Amplifier
RE     141506   Horn Antenna 15-40GHz     Schwarzbeck       BBHA9170        BBHA9170307          06/08/2018    06/30/2019    12
RE     141508   Horn Antenna 1-18GHz      Schwarzbeck       BBHA9120D       9120D-557            06/08/2018    06/30/2019    12
RE     142017   AC4_Semi Anechoic         TDK               Semi Anechoic   DA-10005             04/07/2018    04/30/2019    12
                Chamber(SVSWR)                              Chamber 3m
RE     141425   Biconical Antenna         Schwarzbeck       BBA9106         1302                 06/01/2018    06/30/2019    12
RE     141397   Coaxial Cable             UL Japan          -               -                    06/13/2018    06/30/2019    12
RE     141267   Logperiodic               Schwarzbeck       VUSLP9111B      911B-192             06/01/2018    06/30/2019    12
                Antenna(200-1000MHz)
RE     141951   EMI Test Receiver         Rohde & Schwarz   ESR26           101408               01/30/2018    01/31/2019    12
RE     141583   Pre Amplifier             SONOMA            310             260833               02/27/2018    02/28/2019    12
                                          INSTRUMENT


*Hyphens for Last Calibration Date, Calibration Due Date and Cal Int (month) are instruments that Calibration
is not required (e.g. software), or instruments checked in advance before use.

The expiration date of the calibration is the end of the expired month.
All equipment is calibrated with valid calibrations. Each measurement data is traceable to the national or
international standards.

As for some calibrations performed after the tested dates, those test equipment have been controlled by means of
an unbroken chains of calibrations.

Test item:
          RE: Radiated emission




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124



Document Created: 2019-03-27 23:16:23
Document Modified: 2019-03-27 23:16:23

© 2024 FCC.report