03 FCC Test Report_DSC

FCC ID: ACJ932IK4310E

Test Report

Download: PDF
FCCID_4151267

                                                                                Test report No.         : 12541456H
                                                                                Page                    : 1 of 19
                                                                                Issued date             : January 28, 2019
                                                                                FCC ID                  : ACJ932IK4310E




                             RADIO TEST REPORT
                                 Test Report No. : 12541456H
         Applicant                             :     Panasonic Corporation of North America

         Type of Equipment                     :     PESS FOB

         Model No.                             :     IK4310E

         FCC ID                                :     ACJ932IK4310E

         Test regulation                       :     FCC Part 15 Subpart C: 2018

         Test Result                           :     Complied (Refer to SECTION 3.2)
           1.   This test report shall not be reproduced in full or partial, without the written approval of UL Japan, Inc.
           2.   The results in this report apply only to the sample tested.
           3.   This sample tested is in compliance with the above regulation.
           4.   The test results in this report are traceable to the national or international standards.
           5.   This test report must not be used by the customer to claim product certification, approval, or
                endorsement by NVLAP, NIST, or any agency of the Federal Government.
           6.   This test report covers Radio technical requirements. It does not cover administrative issues
                such as Manual or non-Radio test related Requirements. (if applicable)
           7.   The all test items in this test report are conducted by UL Japan, Inc. Ise EMC Lab.
           8.   The information provided from the customer for this report is identified in SECTION 1.

                          Date of test:               November 5, 2018 to January 21, 2019

                          Representative test
                          engineer:
                                                                Tomoki Matsui
                                                                   Engineer
                                                          Consumer Technology Division


                          Approved by:
                                                               Shinichi Miyazono
                                                                    Engineer
                                                          Consumer Technology Division

                                                             This laboratory is accredited by the NVLAP LAB CODE
                                                             200572-0, U.S.A. The tests reported herein have been
                                                             performed in accordance with its terms of accreditation.
                                                             *As for the range of Accreditation in NVLAP, you may
                                                             refer to the WEB address,
                                                             http://japan.ul.com/resources/emc_accredited/

        NVLAP LAB CODE: 200572-0

     The testing in which "Non-accreditation" is displayed is outside the accreditation scopes in UL Japan.
     There is no testing item of "Non-accreditation".

UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124                                                                             13-EM-F0429


                                                                       Test report No.   : 12541456H
                                                                       Page              : 2 of 19
                                                                       Issued date       : January 28, 2019
                                                                       FCC ID            : ACJ932IK4310E




                                    REVISION HISTORY
                                  Original Test Report No.: 12541456H

 Revision       Test report No.      Date               Page revised      Contents
 -              12541456H            January 28, 2019   -                 -
 (Original)




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                                             Test report No.            : 12541456H
                                                                                             Page                       : 3 of 19
                                                                                             Issued date                : January 28, 2019
                                                                                             FCC ID                     : ACJ932IK4310E


CONTENTS                                                                                                                              PAGE

SECTION 1: Customer information.......................................................................................................4
SECTION 2: Equipment under test (E.U.T.) .........................................................................................4
SECTION 3: Test specification, procedures & results..........................................................................5
SECTION 4: Operation of E.U.T. during testing ..................................................................................8
SECTION 5: Radiated emission (Electric Field Strength of Fundamental and Spurious Emission)9
SECTION 6: Automatically deactivate ................................................................................................11
SECTION 7: -20 dB and 99 % Occupied Bandwidth .........................................................................11
APPENDIX 1: Test data ........................................................................................................................12
    Automatically deactivate................................................................................................................... 12
    Radiated Emission (Electric Field Strength of Fundamental and Spurious Emission) ..................... 13
    -20dB and 99% Occupied Bandwidth ............................................................................................... 15
APPENDIX 2: Test instruments ...........................................................................................................16
APPENDIX 3: Photographs of test setup .............................................................................................17
    Radiated emission ............................................................................................................................. 17
    Worst case position ........................................................................................................................... 18




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                          Test report No.      : 12541456H
                                                                          Page                 : 4 of 19
                                                                          Issued date          : January 28, 2019
                                                                          FCC ID               : ACJ932IK4310E


SECTION 1:          Customer information
 Company Name                             :    Panasonic Corporation of North America*1)
 Address                                  :    Two Riverfront Plaza, 9th Floor Newark, NJ 07102-5490
 Telephone Number                         :    +1-201-348-7760
 Facsimile Number                         :    +1-201-348-7760
 Contact Person                           :    Ben Botros

The information provided from the customer is as follows;
- Applicant, Type of Equipment, Model No. on the cover and other relevant pages
- SECTION 1: Customer information
- SECTION 2: Equipment under test (E.U.T.)
- SECTION 4: Operation of E.U.T. during testing
* The laboratory is exempted from liability of any test results affected from the information in SECTION 2 and 4.

*1) Panasonic Corporation of North America designates Panasonic Automotive Systems Asia Pacific Co.,Ltd
     as manufacturer of the product (PESS FOB).



SECTION 2:          Equipment under test (E.U.T.)
2.1       Identification of E.U.T.

 Type of Equipment                        :    PESS FOB
 Model No.                                :    IK4310E
 Serial No.                               :    Refer to Section 4, Clause 4.2
 Rating                                   :    DC 3.0 V
 Receipt Date of Sample                   :    October 30, 2018
 (Information from test lab.)
 Country of Mass-production               :    Thailand
 Condition of EUT                         :    Production prototype
                                               (Not for Sale: This sample is equivalent to mass-produced items.)
 Modification of EUT                      :    No Modification by the test lab


2.2       Product Description

 Model: IK4310E (referred to as the EUT in this report) is a PESS FOB.

Radio Specification

 Radio Type                               :    Transceiver
 Frequency of Operation                   :    433.92 MHz
 Modulation                               :    FSK
 Antenna type                             :    PCB pattern and plate antenna
 Clock frequency (Maximum)                :    27.6 MHz

 Radio Type                               :    Receiver
 Frequency of Operation                   :    125 kHz *1)

*1) The test of receiver part was performed separately from this test report, and the conformability is confirmed.




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                                 Test report No.        : 12541456H
                                                                                 Page                   : 5 of 19
                                                                                 Issued date            : January 28, 2019
                                                                                 FCC ID                 : ACJ932IK4310E


SECTION 3:            Test specification, procedures & results

3.1         Test Specification

  Test Specification          :     FCC Part 15 Subpart C
                                    FCC Part 15 final revised on March 12, 2018 and effective April 11, 2018

  Title                       :     FCC 47CFR Part15 Radio Frequency Device Subpart C Intentional Radiators
                                    Section 15.231 Periodic operation in the band 40.66-40.70 MHz and above 70 MHz.


3.2         Procedures and results

Item                        Test Procedure          Specification                 Worst margin            Results      Remarks
                            FCC: ANSI C63.10:2013 FCC: Section 15.207
                            6 Standard test methods
                                                                                  N/A
Conducted emission                                                                                        N/A          -
                            IC: RSS-Gen 8.8            IC: RSS-Gen 8.8            *1)


                            FCC: ANSI C63.10:2013 FCC: Section
                            6 Standard test methods 15.231(a)(1)                                          Complied
Automatically Deactivate                                                          N/A                                  Radiated
                                                                                                          a)
                            IC: -                      IC: RSS-210 A1.1
                            FCC: ANSI C63.10:2013 FCC: Section 15.231(b)          0.0 dB
Electric Field Strength     6 Standard test methods                               433.920 MHz             Complied#
                                                                                                                       Radiated
of Fundamental Emission                                                           Horizontal              b)
                            IC: RSS-Gen 6.12           IC: RSS-210 A1.2           PK with Duty factor
                            FCC: ANSI C63.10:2013 FCC: Section 15.205
                                                                                  0.5 dB
                            6 Standard test methods      Section 15.209
Electric Field Strength                                                           4339.200 MHz            Complied#
                                                         Section 15.231(b)                                             Radiated
of Spurious Emission                                                              Vertical                c)
                            IC: RSS-Gen 6.13        IC: RSS-210 A1.2, 4.4
                                                                                  PK with Duty factor
                                                        RSS-Gen 8.9
                            FCC: ANSI C63.10:2013 FCC: Section 15.231(c)
                            6 Standard test methods
                                                                                                          Complied
-20dB Bandwidth                                                                   N/A                                  Radiated
                                                                                                          d)
                            IC: -                      IC: Reference data

Note: UL Japan, Inc.’s EMI Work Procedures No. 13-EM-W0420 and 13-EM-W0422.
*1) The test is not applicable since the EUT does not have AC Mains.

a) Refer to Appendix 1 (data of Automatically Deactivate)
b) Refer to Appendix 1 (data of Radiated Emission (Electric Field Strength of Fundamental and Spurious Emission))
c) Refer to Appendix 1 (data of Radiated Emission (Electric Field Strength of Fundamental and Spurious Emission)
d) Refer to Appendix 1 (data of -20dB and 99% Occupied Bandwidth)
Symbols:
 Complied           The data of this test item has enough margin, more than the measurement uncertainty.
 Complied#          The data of this test item meets the limits unless the measurement uncertainty is taken into consideration.

FCC 15.31 (e)
This test was performed with the New Battery (DC 3.0 V) during the tests. Therefore, the EUT complies with the
requirement.

FCC Part 15.203 Antenna requirement
It is impossible for end users to replace the antenna, because the antenna is mounted inside of the EUT. Therefore, the
equipment complies with the antenna requirement of Section 15.203.




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                                 Test report No.        : 12541456H
                                                                                 Page                   : 6 of 19
                                                                                 Issued date            : January 28, 2019
                                                                                 FCC ID                 : ACJ932IK4310E


3.3         Addition to standard

Item                       Test Procedure    Specification        Worst margin               Results              Remarks
99 % Occupied                                                                                Complied
                           IC: RSS-Gen 6.7 IC: RSS-210 A1.3       N/A                                             Radiated
Bandwidth                                                                                    a)
Note: UL Japan, Inc.’s EMI Work Procedures No. 13-EM-W0420 and 13-EM-W0422.

a) Refer to Appendix 1 (data of -20dB and 99% Occupied Bandwidth)
Symbols:
 Complied           The data of this test item has enough margin, more than the measurement uncertainty.
 Complied#          The data of this test item meets the limits unless the measurement uncertainty is taken into consideration.
Other than above, no addition, exclusion nor deviation has been made from the standard.


3.4         Uncertainty

EMI
There is no applicable rule of uncertainty in this applied standard. Therefore, the following results are derived depending on whether or not
laboratory uncertainty is applied.

The following uncertainties have been calculated to provide a confidence level of 95 % using a coverage factor k = 2.

                                                Radiated emission (Below 1 GHz)
        Polarity                    (3 m*)(+/-)                                 (10 m*)(+/-)
                     30 MHz to 200 MHz    200 MHz to 1000 MHz    30 MHz to 200 MHz    200 MHz to 1000 MHz
       Horizontal         4.8 dB                5.2 dB                  4.8 dB               5.0 dB
        Vertical          5.0 dB                6.3 dB                  4.9 dB               5.0 dB

                                               Radiated emission (Above 1 GHz)
                   (3 m*)(+/-)                                     (1 m*)(+/-)                            (10 m*)(+/-)
      1 GHz to 6 GHz      6 GHz to 18 GHz        10 GHz to 26.5 GHz      26.5 GHz to 40 GHz             1 GHz to 18 GHz
          5.0 dB               5.3 dB                   5.8 dB                 5.8 dB                        5.2 dB
* Measurement distance

      Automatically Deactivate
      0.10 %

      Bandwidth
      0.96 %




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                                       Test report No.          : 12541456H
                                                                                       Page                     : 7 of 19
                                                                                       Issued date              : January 28, 2019
                                                                                       FCC ID                   : ACJ932IK4310E


3.5         Test Location

UL Japan, Inc. Ise EM C Lab.
4383-326 Asama-cho, Ise-shi, M ie-ken 516-0021 JAPAN
Telephone: +81 596 24 8999, Facsimile: +81 596 24 8124
NVLAP Lab. code: 200572-0 / FCC Test Firm Registration Number: 199967
                                                                                                                              M aximum
                       IC Registration Width x Depth x          Size of reference ground plane (m) /
Test site                                                                                                Other rooms          measurement
                       Number          Height (m)               horizontal conducting plane
                                                                                                                              distance
No.1 semi-anechoic                                                                                        No.1 Power source
                         2973C-1           19.2 x 11.2 x 7.7     7.0 x 6.0                                                    10 m
chamber                                                                                                   room
No.2 semi-anechoic
                         2973C-2           7.5 x 5.8 x 5.2       4.0 x 4.0                                -                   3m
chamber
No.3 semi-anechoic                                                                                        No.3 Preparation
                         2973C-3           12.0 x 8.5 x 5.9      6.8 x 5.75                                                   3m
chamber                                                                                                   room
No.3 shielded room       -                 4.0 x 6.0 x 2.7       N/A                                      -                   -
No.4 semi-anechoic                                                                                        No.4 Preparation
                         2973C-4           12.0 x 8.5 x 5.9      6.8 x 5.75                                                   3m
chamber                                                                                                   room
No.4 shielded room       -                 4.0 x 6.0 x 2.7       N/A                                      -                   -
No.5 semi-anechoic
                         -                 6.0 x 6.0 x 3.9       6.0 x 6.0                                -                   -
chamber
No.6 shielded room       -                 4.0 x 4.5 x 2.7       4.0 x 4.5                                -                   -
No.6 measurement
                         -                 4.75 x 5.4 x 3.0      4.75 x 4.15                              -                   -
room
No.7 shielded room       -                 4.7 x 7.5 x 2.7       4.7 x 7.5                                -                   -
No.8 measurement
                         -                 3.1 x 5.0 x 2.7       N/A                                      -                   -
room
No.9 measurement
                         -                 8.8 x 4.6 x 2.8       2.4 x 2.4                                -                   -
room
No.11 measurement
                         -                 6.2 x 4.7 x 3.0       4.8 x 4.6                                -                   -
room
* Size of vertical conducting plane (for Conducted Emission test) : 2.0 m x 2.0 m for No.1, No.2, No.3, and No.4 semi-
anechoic chambers and No.3 and No.4 shielded rooms.



3.6         Test data, Test instruments, and Test set up

Refer to APPENDIX.




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                        Test report No.      : 12541456H
                                                                        Page                 : 8 of 19
                                                                        Issued date          : January 28, 2019
                                                                        FCC ID               : ACJ932IK4310E


SECTION 4:         Operation of E.U.T. during testing

4.1       Operating Mode(s)

 Test Item*                                               Mode
 Automatically Deactivate                                 Normal use mode *2)
 Electric Field Strength of Fundamental Emission          Transmitting mode (Tx) *1)
 Electric Field Strength of Spurious Emission
 -20 dB & 99 % Occupied Bandwidth
 * The system was configured in typical fashion (as a user would normally use it) for testing.
 *1) The software of this mode is the same as one of normal product, except that EUT continues to transmit when
     transmitter button is being pressed (For Normal use mode, EUT stops to transmit in a given time, even if
     transceiver button is being pressed.)
    End users cannot change the settings of the output power of the product.
 *2) Normal use mode has the following two operations;
     - Transmission by a button-pressed operation
     - Smart operation to transmit after LF signal is received
    The test was performed by a button-pressed operation as representative, since they are completely identical in
    RF characteristics.


4.2       Configuration and peripherals




                                                            A




                  * Setup was taken into consideration and test data was taken under worse case conditions.

Description of EUT
  No. Item               Model number         Serial number         Manufacturer                     Remarks
  A     PESS FOB         IK4310E              6422630 *1)           Panasonic Automotive             EUT
                                              6422548 *2)           Systems Asia Pacific Co.,Ltd
*1) Used for Transmitting mode
*2) Used for Normal use mode




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                        Test report No.          : 12541456H
                                                                        Page                     : 9 of 19
                                                                        Issued date              : January 28, 2019
                                                                        FCC ID                   : ACJ932IK4310E


SECTION 5: Radiated emission (Electric Field Strength of Fundamental and Spurious
Emission)
Test Procedure and conditions

[For below 30 MHz]
The noise level was checked by moving a search-coil (Loop Antenna) close to the EUT.

[For 30 MHz to 1 GHz]
EUT was placed on a urethane platform of nominal size, 0.5 m by 1.0 m, raised 0.8 m above the conducting ground plane.
The Radiated Electric Field Strength has been measured in a Semi Anechoic Chamber with a ground plane.

[For above 1 GHz]
EUT was placed on a urethane platform of nominal size, 0.5 m by 0.5 m, raised 1.5 m above the conducting ground plane.
The Radiated Electric Field Strength has been measured in a Semi Anechoic Chamber with absorbent materials lined on a
ground plane.

The measuring antenna height was varied between 1 and 4 m and EUT was rotated a full revolution in order to obtain the
maximum value of the electric field strength.
The measurements were performed for both vertical and horizontal antenna polarization.
The radiated emission measurements were made with the following detector function of the test receiver / spectrum analyzer.

Test Antennas are used as below;
    Frequency            30 MHz to 200 MHz                200 MHz to 1 GHz                     Above 1 GHz
    Antenna Type         Biconical                        Logperiodic                          Horn

                     From 9 kHz          From            From           From                From             Above 1 GHz
                    to 90 kHz and       90 kHz         150 kHz        490 kHz              30 MHz
                    From 110 kHz      to 110 kHz      to 490 kHz     to 30 MHz            to 1 GHz
                      to 150 kHz
    Detector             Peak            Peak            Peak           Peak          Peak and         Peak and
    Type                                                                             Peak with         Peak with Duty factor
                                                                                     Duty factor
    IF Bandwidth       200 Hz           200 Hz          9.0 kHz       9.0 kHz         120 kHz          PK: S/A: RBW 1 MHz,
                                                                                                              VBW: 3 MHz




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                           Test report No.        : 12541456H
                                                                           Page                   : 10 of 19
                                                                           Issued date            : January 28, 2019
                                                                           FCC ID                 : ACJ932IK4310E


[Test Setup]

 Below 1 GHz
                                                                Test Distance: 3 m




 1 GHz - 10 GHz
                                                                Distance Factor: 20 x log (3.75 m / 3.0 m) = 1.94 dB
                                                                * Test Distance: (3 + Test Volume /2) - r = 3.75 m

                                                                Test Volume : 1.5 m
                                                                (Test Volume has been calibrated based on CISPR 16-1-4.)
                                                                 r = 0.0 m

                                                                * The test was performed with r = 0.0 m since EUT is small
                                                                and it was the rather conservative condition.




- The carrier level (or, noise levels) was (or were) measured at each position of all three axes X, Y and Z, and the position
that has the maximum noise was determined.
Noise levels of all the frequencies were measured at the position.

This EUT has two modes which mechanical key is inserted or not. The worst case was confirmed with and without
mechanical key, as a result, the test with mechanical key was the worst case. Therefore the test with mechanical key was
performed only.

*The result is rounded off to the second decimal place, so some differences might be observed.


Measurement range               : 9 kHz – 4.4 GHz
Test data                       : APPENDIX
Test result                     : Pass




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                               Test report No.       : 12541456H
                                                                               Page                  : 11 of 19
                                                                               Issued date           : January 28, 2019
                                                                               FCC ID                : ACJ932IK4310E


SECTION 6:            Automatically deactivate

Test Procedure

The measurement was performed with Electric field strength using a spectrum analyzer.

Test data                          : APPENDIX
Test result                        : Pass



SECTION 7:           -20 dB and 99 % Occupied Bandwidth
Test Procedure

The test was measured with a spectrum analyzer using a test fixture.

 Test                Span                      RBW        VBW           Sweep            Detector   Trace        Instrument used
 20 dB Bandwidth      300 kHz                  3 kHz      9.1 kHz       Auto             Peak       Max Hold     Spectrum Analyzer
 99 % Occupied        Enough width to display  1 to 5 %   Three times   Auto             Peak       Max Hold     Spectrum Analyzer
 Bandwidth            emission skirts          of OBW     of RBW
 Peak hold was applied as Worst-case measurement.

Test data                          : APPENDIX
Test result                        : Pass




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                          Test report No.            : 12541456H
                                                                          Page                       : 12 of 19
                                                                          Issued date                : January 28, 2019
                                                                          FCC ID                     : ACJ932IK4310E


APPENDIX 1: Test data

                                                Automatically deactivate

               Report No.                    12541456H
               Test place                    Ise EMC Lab.
               Shielded Room                 No.6
               Date                          January 21, 2019
               Temperature / Humidity        24 deg. C / 33% RH
               Engineer                      Hiroyiuki Furutaka
               Mode                          Normal use mode

                                Time of                           Limit                     Result
                              Transmitting
                                  [sec]                           [sec]
                                 0.2723                           5.00                      Pass




* The EUT transmits UHF when LF signal is received from a car or a button on the EUT is pressed. In both cases, the UHF
transmission is stopped within 5 seconds. So the test was performed by a button-pressed operation as the worst case.
Please refer to the “Theory of Operation” for details.




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                                                    Test report No.             : 12541456H
                                                                                                    Page                        : 13 of 19
                                                                                                    Issued date                 : January 28, 2019
                                                                                                    FCC ID                      : ACJ932IK4310E


          Radiated Emission (Electric Field Strength of Fundamental and Spurious Emission)
                    Report No.                            12541456H
                    Test place                            Ise EMC Lab.
                    Semi Anechoic Chamber                 No.3                            No.2
                    Date                                  November 5, 2018                November 26, 2018
                    Temperature / Humidity                25 deg. C / 41 % RH             20 deg. C / 40 % RH
                    Engineer                              Junki Nagatomi                  Tomoki Matsui
                                                          Below 1GHz                      Above 1GHz
                    Mode                                  Transmitting mode (Tx)

QP or PK
 Frequency      Detector     Reading             Ant       Loss     Gain     Duty             Result         Limit        M argin                Remark
                              [dBuV]            Factor                       Factor        [dBuV/m]                        [dB]             Inside or Outside
   [M Hz]                  Hor       Ver       [dB/m]      [dB]     [dB]      [dB]        Hor        Ver   [dBuV/m]    Hor        Ver     of Restricted Bands
     433.920 PK             85.4      84.8         16.5      11.0     32.1            -    80.8       80.2    100.8     20.0       20.6 Carrier
     867.840   PK           43.0        40.6      22.0       13.5     31.2            -    47.3        44.9     80.8    33.5         35.9   Outside
    1301.760   PK           45.2        45.0      25.9        3.8     35.3            -    39.6        39.4     73.9    34.3         34.5   Inside
    1735.680   PK           47.4        46.4      25.5        4.1     34.8            -    42.2        41.2     80.8    38.6         39.6   Outside
    2169.600   PK           44.5        44.7      28.3        4.4     34.5            -    42.7        42.9     80.8    38.1         37.9   Outside
    2603.520   PK           46.0        45.5      27.9        4.6     34.4            -    44.1        43.6     80.8    36.7         37.2   Outside
    3037.440   PK           45.9        46.5      28.9        4.8     34.3            -    45.3        45.9     80.8    35.5         34.9   Outside
    3471.360   PK           49.4        52.1      29.1        5.0     33.9            -    49.6        52.3     80.8    31.2         28.5   Outside
    3905.280   PK           47.2        48.4      30.0        5.2     33.6            -    48.8        50.0     73.9    25.1         23.9   Inside
    4339.200   PK           50.2        50.9      30.7        5.4     33.6            -    52.7        53.4     73.9    21.2         20.5   Inside



PK with Duty factor
 Frequency      Detector      Reading           Ant        Loss     Gain     Duty             Result          Limit       M argin                     Remark
                              [dBuV]           Factor                        Factor         [dBuV/m]                       [dB]
   [M Hz]                  Hor      Ver        [dB/m]      [dB]     [dB]     [dB]         Hor      Ver   [dBuV/m]      Hor          Ver
     433.920 PK             85.4     84.8         16.5       11.0     32.1      0.0        80.8     80.2     80.8        0.0          0.6 Carrier               キャリアをQPで
     867.840 PK             43.0     40.6         22.0       13.5     31.2      0.0        47.3     44.9     60.8       13.5         15.9 Outside               キャリアをQPで
    1301.760 PK             45.2     45.0         25.9        3.8     35.3      0.0        39.6     39.4     53.9       14.3         14.5 Inside                キャリアをQPで
    1735.680   PK           47.4        46.4      25.5        4.1     34.8       0.0       42.2        41.2     60.8    18.6         19.6   Outside
    2169.600   PK           44.5        44.7      28.3        4.4     34.5       0.0       42.7        42.9     60.8    18.1         17.9   Outside
    2603.520   PK           46.0        45.5      27.9        4.6     34.4       0.0       44.1        43.6     60.8    16.7         17.2   Outside
    3037.440   PK           45.9        46.5      28.9        4.8     34.3       0.0       45.3        45.9     60.8    15.5         14.9   Outside
    3471.360   PK           49.4        52.1      29.1        5.0     33.9       0.0       49.6        52.3     60.8    11.2          8.5   Outside
    3905.280 PK             47.2        48.4      30.0        5.2     33.6       0.0       48.8        50.0     53.9     5.1          3.9 Inside
    4339.200 PK             50.2        50.9      30.7        5.4     33.6       0.0       52.7        53.4     53.9     1.2          0.5 Inside



Sample calculation:
Result of PK = Reading + Ant Factor + Loss (Cable + Attenuator + Filter +Distance factor) - Gain (Amplifier)
Result of PK with Duty factor = Reading + Ant Factor + Loss (Cable + Attenuator + Filter +Distance factor) - Gain (Amplifier) + Duty
factor

For above 1GHz : Distance Factor: 20 x log (3.75 m/3.0 m) = 1.94 dB
*Other frequency noises omitted in this report were not seen or had enough margin (more than 20dB).

Since the peak emission result satisfied the average limit, duty factor was omitted.
Although Duty of this product was 100% or less, the result of AV (PK with Duty factor) was calculated by applying Duty
100% as worst.




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                                                  Test report No.   : 12541456H
                                                                                                  Page              : 14 of 19
                                                                                                  Issued date       : January 28, 2019
                                                                                                  FCC ID            : ACJ932IK4310E


                                                            Radiated Spurious Emission
                                                              (Plot data, Worst case)

               Report No.                                  12541456H
               Test place                                  Ise EMC Lab.
               Semi Anechoic Chamber                       No.3                          No.2
               Date                                        November 5, 2018              November 26, 2018
               Temperature / Humidity                      25 deg. C / 41% RH            20 deg. C / 40% RH
               Engineer                                    Junki Nagatomi                Tomoki Matsui
                                                           Below 1GHz                    Above 1GHz
               Mode                                        Transmitting mode (Tx)



                                                                             Horizontal
                                                110
                                                100
                                                 90
                      Field strength [dBuV/m]




                                                 80
                                                 70
                                                 60
                                                 50
                                                 40
                                                 30
                                                 20
                                                 10
                                                      10               100                         1000               10000
                                                                              Frequency [MHz]

                                                                Peak           Average          Average Limit



                                                                              Vertical
                                                110
                                                100
                                                90
                      Field strength [dBuV/m]




                                                80
                                                70
                                                60
                                                50
                                                40
                                                30
                                                20
                                                10
                                                      10               100                         1000               10000
                                                                              Frequency [MHz]

                                                                Peak           Average          Average Limit


            *These plots data contains sufficient number to show the trend of characteristic features for EUT.




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                               Test report No.             : 12541456H
                                                                               Page                        : 15 of 19
                                                                               Issued date                 : January 28, 2019
                                                                               FCC ID                      : ACJ932IK4310E


                                        -20dB and 99% Occupied Bandwidth


               Report No.                   12541456H
               Test place                   Ise EMC Lab.
               Shielded Room                No.6
               Date                         January 21, 2019
               Temperature / Humidity       24 deg. C / 33% RH
               Engineer                     Hiroyiuki Furutaka
               Mode                         Transmitting mode (Tx)



                 Bandwidth Limit : Fundamental Frequency        433.92 MHz x 0.25% =             1084.80      kHz
              * The above limit was calculated from more stringent nominal frequency.


                  -20dB Bandwidth                Bandwidth Limit             Result
                       [kHz]                         [kHz]
                       42.14                          1084.80                 Pass


              99% Occupied Bandwidth             Bandwidth Limit             Result
                      [kHz]                          [kHz]
                       65.27                          1084.80                 Pass




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                          Test report No.          : 12541456H
                                                                          Page                     : 16 of 19
                                                                          Issued date              : January 28, 2019
                                                                          FCC ID                   : ACJ932IK4310E


APPENDIX 2: Test instruments
Test Instruments
 Test   LIMS     Description         Manufacturer     Model           Serial                Last          Calibration   Cal
 Item   ID                                                                                  Calibration   Due Date      Int
                                                                                            Date
 RE     141323   Coaxial cable       UL Japan         -               -                     7/3/2018      7/31/2019     12
 RE     141532   DIGITAL HiTESTER    HIOKI            3805            51201197              1/9/2018      1/31/2019     12
 RE     141266   Logperiodic         Schwarzbeck      VUSLP9111B      911B-191              6/4/2018      6/30/2019     12
                 Antenna(200-
                 1000MHz)
 RE     142183   Measure             KOMELON          KMC-36          -                     -             -             -
 RE     148897   Attenuator          KEYSIGHT         8491A           MY52462349            12/20/2018    12/31/2019    12
 RE     142008   AC3_Semi Anechoic   TDK              Semi Anechoic   DA-10005              6/26/2018     6/30/2020     24
                 Chamber(NSA)                         Chamber 3m
 RE     141949   Test Receiver       Rohde &          ESCI            100767                8/6/2018      8/31/2019     12
                                     Schwarz
 RE     141554   Thermo-Hygrometer   CUSTOM           CTH-180         1301                  1/24/2018     1/31/2019     12
 RE     141424   Biconical Antenna   Schwarzbeck      BBA9106         1915                  6/4/2018      6/30/2019     12
 RE     141582   Pre Amplifier       SONOMA           310             260834                2/27/2018     2/28/2019     12
                                     INSTRUMENT
 RE     141152   EMI measurement     TSJ              TEPTO-DV        -                     -             -             -
                 program
 RE     141556   Thermo-Hygrometer   CUSTOM           CTH-201         0003                  12/5/2018     12/31/2019    12
 RE     142004   AC2_Semi Anechoic   TDK              Semi Anechoic   DA-06902              6/29/2018     6/30/2020     24
                 Chamber(NSA)                         Chamber 3m
 RE     141579   Pre Amplifier       AGILENT          8449B           3008A02142            1/21/2019     1/31/2020     12
 RE     141392   Microwave Cable     Junkosha         MWX221          1604S253(1 m) /       8/8/2018      8/31/2019     12
                                                                      1608S087(5 m)
 RE     142228   Measure             KOMELON          KMC-36          -                     -             -             -
 RE     141507   Horn Antenna 1-     Schwarzbeck      BBHA9120D       258                   6/7/2018      6/30/2019     12
                 18GHz
 RE     141542   Digital Tester      Fluke            FLUKE 26-3      78030611              8/21/2018     8/31/2019     12
                                     Corporation
 RE     142006   AC2_Semi Anechoic   TDK              Semi Anechoic   DA-06902              4/1/2018      4/30/2019     12
                 Chamber(SVSWR)                       Chamber 3m
 RE     141900   Spectrum Analyzer   AGILENT          E4440A          MY46185823            11/15/2018    11/30/2019    12
 RE     142645   Loop Antenna        UL Japan         -               -                     -             -             -
 RE     141561   Thermo-Hygrometer   CUSTOM           CTH-201         1401                  1/11/2019     1/31/2020     12
 RE     142645   Loop Antenna        UL Japan         -               -                     -             -             -

*Hyphens for Last Calibration Date, Calibration Due Date and Cal Int (month) are instruments that Calibration is
not required (e.g. software), or instruments checked in advance before use.

The expiration date of the calibration is the end of the expired month.
All equipment is calibrated with valid calibrations. Each measurement data is traceable to the national or
international standards.

As for some calibrations performed after the tested dates, those test equipment have been controlled by means of an
unbroken chains of calibrations.

Test item:
RE: Radiated emission, 99 % Occupied Bandwidth, -20 dB bandwidth, and Automatically deactivate tests




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124



Document Created: 2019-01-28 11:54:18
Document Modified: 2019-01-28 11:54:18

© 2024 FCC.report