03 FCC Test Report_DSC

FCC ID: ACJ932IK3600F

Test Report

Download: PDF
FCCID_4154791

                                                                                 Test report No.        : 12541448H-R1
                                                                                 Page                   : 1 of 18
                                                                                 Issued date            : January 31, 2019
                                                                                 FCC ID                 : ACJ932IK3600F



                              RADIO TEST REPORT
                                Test Report No. : 12541448H-R1
        Applicant                             :     Panasonic Corporation of North America

        Type of Equipment                     :     RKE TXE

        Model No.                             :     IK3600F

        FCC ID                                :     ACJ932IK3600F

        Test regulation                       :     FCC Part 15 Subpart C: 2018

        Test Result                           :     Complied (Refer to SECTION 3.2)
        1.      This test report shall not be reproduced in full or partial, without the written approval of UL Japan, Inc.
        2.      The results in this report apply only to the sample tested.
        3.      This sample tested is in compliance with the above regulation.
        4.      The test results in this report are traceable to the national or international standards.
        5.      This test report covers Radio technical requirements. It does not cover administrative issues such as
                Manual or non-Radio test related Requirements. (if applicable)
        6.      The all test items in this test report are conducted by UL Japan, Inc. Ise EMC Lab.
        7.      This test report must not be used by the customer to claim product certification, approval, or
                endorsement by NVLAP, NIST, or any agency of the Federal Government.
        8.      The information provided from the customer for this report is identified in SECTION 1.
        9.      This report is a revised version of 12541448H. 12541448H is replaced with this report.

                         Date of test:                           December 5, 2018

                         Representative test
                         engineer:
                                                              Hiroyuki Furutaka
                                                                  Engineer
                                                         Consumer Technology Division


                         Approved by:
                                                              Shinichi Miyazono
                                                                   Engineer
                                                         Consumer Technology Division

                                                            This laboratory is accredited by the NVLAP LAB CODE
                                                            200572-0, U.S.A. The tests reported herein have been
                                                            performed in accordance with its terms of accreditation.
                                                            *As for the range of Accreditation in NVLAP, you may
                                                            refer to the WEB address,
                                                            http://japan.ul.com/resources/emc_accredited/

       NVLAP LAB CODE: 200572-0

    The testing in which "Non-accreditation" is displayed is outside the accreditation scopes in UL Japan.
    There is no testing item of "Non-accreditation".

UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124                                                                             13-EM-F0429


                                                                   Test report No.    : 12541448H-R1
                                                                   Page               : 2 of 18
                                                                   Issued date        : January 31, 2019
                                                                   FCC ID             : ACJ932IK3600F




                                   REVISION HISTORY
                                 Original Test Report No.: 12541448H

Revision       Test report No.       Date                Page      Contents
                                                         revised
-              12541448H             January 28, 2019    -         -
(Original)
1              12541448H-R1           January 31, 2019   P.8       Deletion of “Duty Cycle” from Test Item in
                                                                   Clause 4.1
1              12541448H-R1           January 31, 2019   P.18      Correction of axis name in Worst case
                                                                   position




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                                             Test report No.            : 12541448H-R1
                                                                                             Page                       : 3 of 18
                                                                                             Issued date                : January 31, 2019
                                                                                             FCC ID                     : ACJ932IK3600F


CONTENTS                                                                                                                              PAGE

SECTION 1: Customer information.......................................................................................................4
SECTION 2: Equipment under test (E.U.T.) .........................................................................................4
SECTION 3: Test specification, procedures & results..........................................................................5
SECTION 4: Operation of E.U.T. during testing ..................................................................................8
SECTION 5: Radiated emission (Electric Field Strength of Fundamental and Spurious Emission)9
SECTION 6: Automatically deactivate ................................................................................................11
SECTION 7: -20 dB and 99 % Occupied Bandwidth .........................................................................11
APPENDIX 1: Test data ........................................................................................................................12
    Automatically deactivate................................................................................................................... 12
    Radiated Emission (Electric Field Strength of Fundamental and Spurious Emission) ..................... 13
    -20dB and 99% Occupied Bandwidth ............................................................................................... 15
APPENDIX 2: Test instruments ...........................................................................................................16
APPENDIX 3: Photographs of test setup .............................................................................................17
    Radiated emission ............................................................................................................................. 17
    Worst case position ........................................................................................................................... 18




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                         Test report No.     : 12541448H-R1
                                                                         Page                : 4 of 18
                                                                         Issued date         : January 31, 2019
                                                                         FCC ID              : ACJ932IK3600F


SECTION 1:         Customer information
Company Name                           :     Panasonic Corporation of North America*1)
Address                                :     Two Riverfront Plaza, 9th Floor Newark, NJ 07102-5490
Telephone Number                       :     +1-201-348-7760
Facsimile Number                       :     +1-201-348-7760
Contact Person                         :     Ben Botros

The information provided from the customer is as follows;
- Applicant, Type of Equipment, Model No. on the cover and other relevant pages
- SECTION 1: Customer information
- SECTION 2: Equipment under test (E.U.T.)
- SECTION 4: Operation of E.U.T. during testing
* The laboratory is exempted from liability of any test results affected from the information in SECTION 2 and 4.

*1) Panasonic Corporation of North America designates Panasonic Automotive Systems Asia Pacific Co.,Ltd
     as manufacturer of the product (RKE TXE).



SECTION 2:         Equipment under test (E.U.T.)
2.1       Identification of E.U.T.

Type of Equipment                      :     RKE TXE
Model No.                              :     IK3600F
Serial No.                             :     Refer to Section 4, Clause 4.2
Rating                                 :     DC 3.0 V
Receipt Date of Sample                 :     December 4, 2018
(Information from test lab.)
Country of Mass-production             :     Thailand
Condition of EUT                       :     Production prototype
                                             (Not for Sale: This sample is equivalent to mass-produced items.)
Modification of EUT                    :     No Modification by the test lab


2.2       Product Description

Model: IK3600F (referred to as the EUT in this report) is a RKE TXE.

Radio Specification

Radio Type                             :     Transmitter
Frequency of Operation                 :     433.92 MHz
Modulation                             :     FSK
Antenna type                           :     Copper printing monopole antenna
Clock frequency (Maximum)              :     27.6 MHz




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                                 Test report No.          : 12541448H-R1
                                                                                 Page                     : 5 of 18
                                                                                 Issued date              : January 31, 2019
                                                                                 FCC ID                   : ACJ932IK3600F


 SECTION 3:               Test specification, procedures & results

 3.1        Test Specification

 Test Specification            :      FCC Part 15 Subpart C
                                      FCC Part 15 final revised on March 12, 2018 and effective April 11, 2018

 Title                         :      FCC 47CFR Part15 Radio Frequency Device Subpart C Intentional Radiators
                                      Section 15.231 Periodic operation in the band 40.66-40.70 MHz and above 70 MHz.


 3.2        Procedures and results

Item                          Test Procedure          Specification               Worst margin Results              Remarks
                              FCC: ANSI C63.10:2013 FCC: Section 15.207
                              6 Standard test methods
Conducted emission                                                                N/A *1)           N/A             -
                              IC: RSS-Gen 8.8          IC: RSS-Gen 8.8


                              FCC: ANSI C63.10:2013 FCC: Section
                              6 Standard test methods 15.231(a)(1)                                  Complied
Automatically Deactivate                                                          N/A                               Radiated
                                                                                                    a)
                              IC: -                    IC: RSS-210 A1.1
                              FCC: ANSI C63.10:2013 FCC: Section 15.231(b)        1.0 dB
                              6 Standard test methods                             433.920 MHz
Electric Field Strength                                                                             Complied#
                                                                                  Horizontal                        Radiated
of Fundamental Emission                                                                             b)
                              IC: RSS-Gen 6.12         IC: RSS-210 A1.2           PK with Duty
                                                                                  factor
                              FCC: ANSI C63.10:2013 FCC: Section 15.205           1.3 dB
                              6 Standard test methods      Section 15.209         3905.280 MHz
Electric Field Strength                                                                             Complied#
                                                           Section 15.231(b)      Vertical                          Radiated
of Spurious Emission                                                                                c)
                              IC: RSS-Gen 6.13        IC: RSS-210 A1.2, 4.4       PK with Duty
                                                          RSS-Gen 8.9             factor
                              FCC: ANSI C63.10:2013 FCC: Section 15.231(c)
                              6 Standard test methods
                                                                                                    Complied
-20dB Bandwidth                                                                   N/A                               Radiated
                                                                                                    d)
                              IC: -                    IC: Reference data

Note: UL Japan, Inc.’s EMI Work Procedures No. 13-EM-W0420 and 13-EM-W0422.
*1) The test is not applicable since the EUT does not have AC Mains.

a) Refer to APPENDIX 1 (data of Automatically Deactivate)
b) Refer to APPENDIX 1 (data of Radiated Emission (Electric Field Strength of Fundamental and Spurious Emission))
c) Refer to APPENDIX 1 (data of Radiated Emission (Electric Field Strength of Fundamental and Spurious Emission))
d) Refer to APPENDIX 1 (data of -20dB and 99% Occupied Bandwidth)
Symbols:
 Complied           The data of this test item has enough margin, more than the measurement uncertainty.
 Complied#          The data of this test item meets the limits unless the measurement uncertainty is taken into consideration.

 FCC 15.31 (e)
 This test was performed with the New Battery (DC 3.0 V) during the tests. Therefore, the EUT complies with the
 requirement.

 FCC Part 15.203 Antenna requirement
 It is impossible for end users to replace the antenna, because the antenna is mounted inside of the EUT. Therefore, the
 equipment complies with the antenna requirement of Section 15.203.




 UL Japan, Inc.
 Ise EMC Lab.
 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
 Telephone : +81 596 24 8999
 Facsimile : +81 596 24 8124


                                                                                 Test report No.        : 12541448H-R1
                                                                                 Page                   : 6 of 18
                                                                                 Issued date            : January 31, 2019
                                                                                 FCC ID                 : ACJ932IK3600F


3.3         Addition to standard

  Item                     Test Procedure          Specification          Worst margin      Results         Remarks
  99 % Occupied
                           IC: RSS-Gen 6.7         IC: RSS-210 A1.3       N/A               Complied        Radiated
  Bandwidth
Other than above, no addition, exclusion nor deviation has been made from the standard.


3.4         Uncertainty

There is no applicable rule of uncertainty in this applied standard. Therefore, the following results are derived depending on whether or
not laboratory uncertainty is applied.

The following uncertainties have been calculated to provide a confidence level of 95 % using a coverage factor k = 2.

                                               Radiated emission (Below 1 GHz)
      Polarity                     (3 m*)(+/-)                                 (10 m*)(+/-)
                    30 MHz to 200 MHz    200 MHz to 1000 MHz    30 MHz to 200 MHz    200 MHz to 1000 MHz
      Horizontal         4.8 dB                5.2 dB                  4.8 dB               5.0 dB
       Vertical          5.0 dB                6.3 dB                  4.9 dB               5.0 dB

                                             Radiated emission (Above 1 GHz)
                 (3 m*)(+/-)                                     (1 m*)(+/-)                             (10 m*)(+/-)
    1 GHz to 6 GHz      6 GHz to 18 GHz        10 GHz to 26.5 GHz      26.5 GHz to 40 GHz              1 GHz to 18 GHz
         5.0 dB              5.3 dB                   5.8 dB                 5.8 dB                         5.2 dB
* Measurement distance

   Automatically Deactivate
   0.10 %

   Bandwidth
   0.96 %




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                               Test report No.         : 12541448H-R1
                                                                               Page                    : 7 of 18
                                                                               Issued date             : January 31, 2019
                                                                               FCC ID                  : ACJ932IK3600F


3.5         Test Location

UL Japan, Inc. Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone: +81 596 24 8999, Facsimile: +81 596 24 8124
NVLAP Lab. code: 200572-0 / FCC Test Firm Registration Number: 199967
                                                                                                                    Maximum
                     IC Registration Width x Depth x      Size of reference ground plane (m)
Test site                                                                                    Other rooms            measuremen
                     Number          Height (m)           / horizontal conducting plane
                                                                                                                    t distance
No.1 semi-anechoic                                                                               No.1 Power
                     2973C-1         19.2 x 11.2 x 7.7    7.0 x 6.0                                                 10 m
chamber                                                                                          source room
No.2 semi-anechoic
                     2973C-2         7.5 x 5.8 x 5.2      4.0 x 4.0                              -                  3m
chamber
No.3 semi-anechoic                                                                               No.3 Preparation
                     2973C-3         12.0 x 8.5 x 5.9     6.8 x 5.75                                                3m
chamber                                                                                          room
No.3 shielded room   -               4.0 x 6.0 x 2.7      N/A                                    -                  -
No.4 semi-anechoic                                                                               No.4 Preparation
                     2973C-4         12.0 x 8.5 x 5.9     6.8 x 5.75                                                3m
chamber                                                                                          room
No.4 shielded room   -               4.0 x 6.0 x 2.7      N/A                                    -                  -
No.5 semi-anechoic
                     -               6.0 x 6.0 x 3.9      6.0 x 6.0                              -                  -
chamber
No.6 shielded room   -               4.0 x 4.5 x 2.7      4.0 x 4.5                              -                  -
No.6 measurement
                     -               4.75 x 5.4 x 3.0     4.75 x 4.15                            -                  -
room
No.7 shielded room   -               4.7 x 7.5 x 2.7      4.7 x 7.5                              -                  -
No.8 measurement
                     -               3.1 x 5.0 x 2.7      3.1 x 5.0                              -                  -
room
No.9 measurement
                     -               8.8 x 4.6 x 2.8      2.4 x 2.4                              -                  -
room
No.11 measurement
                     -               6.2 x 4.7 x 3.0      4.8 x 4.6                              -                  -
room
* Size of vertical conducting plane (for Conducted Emission test) : 2.0 m x 2.0 m for No.1, No.2, No.3, and No.4
semi-anechoic chambers and No.3 and No.4 shielded rooms.



3.6         Test data, Test instruments, and Test set up

Refer to APPENDIX.




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                          Test report No.       : 12541448H-R1
                                                                          Page                  : 8 of 18
                                                                          Issued date           : January 31, 2019
                                                                          FCC ID                : ACJ932IK3600F


SECTION 4:         Operation of E.U.T. during testing

4.1       Operating Mode(s)

Test Item*                                              Mode
Automatically Deactivate                                Normal use mode
Electric Field Strength of Fundamental Emission         Transmitting mode (Tx) *1)
Electric Field Strength of Spurious Emission
-20 dB & 99 % Occupied Bandwidth
* The system was configured in typical fashion (as a user would normally use it) for testing.
*1) End users cannot change the settings of the output power of the product.



4.2       Configuration and peripherals




                                                           A




* Cabling and setup(s) were taken into consideration and test data was taken under worse case conditions.

Description of EUT
 No. Item                   Model number         Serial number Manufacturer                                 Remarks
 A     RKE TXE              IK3600F              No.33 *1)     Panasonic Automotive Systems                 EUT
                                                 No.18 *2)     Asia Pacific Co.,Ltd
*1) Used for Normal use mode
*2) Used for Transmitting mode




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                         Test report No.         : 12541448H-R1
                                                                         Page                    : 9 of 18
                                                                         Issued date             : January 31, 2019
                                                                         FCC ID                  : ACJ932IK3600F


SECTION 5:         Radiated emission (Electric Field Strength of Fundamental and Spurious
Emission)
Test Procedure and conditions

[For below 30 MHz]
The noise level was checked by moving a search-coil (Loop Antenna) close to the EUT.

[For 30 MHz to 1 GHz]
EUT was placed on a urethane platform of nominal size, 0.5 m by 1.0 m, raised 0.8 m above the conducting ground
plane. The Radiated Electric Field Strength has been measured in a Semi Anechoic Chamber with a ground plane.

[For above 1 GHz]
EUT was placed on a urethane platform of nominal size, 0.5 m by 0.5 m, raised 1.5 m above the conducting ground
plane.
The Radiated Electric Field Strength has been measured in a Semi Anechoic Chamber with absorbent materials lined
on a ground plane.

The measuring antenna height was varied between 1 and 4 m and EUT was rotated a full revolution in order to obtain the
maximum value of the electric field strength.
The measurements were performed for both vertical and horizontal antenna polarization.
The radiated emission measurements were made with the following detector function of the test receiver / spectrum
analyzer.

Test Antennas are used as below;
   Frequency            Below 30 MHz              30 MHz to 200 MHz      200 MHz to 1 GHz           Above 1 GHz
   Antenna Type         Loop                      Biconical              Logperiodic                Horn

                    From 9 kHz          From             From            From           From               Above 1 GHz
                   to 90 kHz and       90 kHz          150 kHz         490 kHz         30 MHz
                   From 110 kHz      to 110 kHz       to 490 kHz      to 30 MHz       to 1 GHz
                     to 150 kHz
  Detector              Peak            Peak             Peak           Peak          Peak and       Peak and
  Type                                                                               Peak with       Peak with Duty factor
                                                                                     Duty factor
  IF Bandwidth        200 Hz           200 Hz          9.0 kHz         9.0 kHz        120 kHz        PK: S/A: RBW 1 MHz,
                                                                                                            VBW: 3 MHz




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                            Test report No.        : 12541448H-R1
                                                                            Page                   : 10 of 18
                                                                            Issued date            : January 31, 2019
                                                                            FCC ID                 : ACJ932IK3600F


[Test Setup]

Below 1 GHz
                                                               Test Distance: 3 m




1 GHz - 10 GHz
                                                               Distance Factor: 20 x log (4.0 m / 3.0 m) = 2.5 dB
                                                               * Test Distance: (3 + Test Volume /2) - r = 4.0 m

                                                               Test Volume : 2.0 m
                                                               (Test Volume has been calibrated based on CISPR 16-1-4.)
                                                                r = 0.0 m

                                                               * The test was performed with r = 0.0 m since EUT is small
                                                               and it was the rather conservative condition.




- The carrier level (or, noise levels) was (or were) measured at each position of all three axes X, Y and Z, and the
position that has the maximum noise was determined.
Noise levels of all the frequencies were measured at the position.

*The result is rounded off to the second decimal place, so some differences might be observed.


Measurement range               : 9 kHz - 4.4 GHz
Test data                       : APPENDIX
Test result                     : Pass




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                               Test report No.      : 12541448H-R1
                                                                               Page                 : 11 of 18
                                                                               Issued date          : January 31, 2019
                                                                               FCC ID               : ACJ932IK3600F


SECTION 6:            Automatically deactivate

Test Procedure

The measurement was performed with Electric field strength using a spectrum analyzer.

Test data                           : APPENDIX
Test result                         : Pass



SECTION 7:            -20 dB and 99 % Occupied Bandwidth
Test Procedure

The test was measured with a spectrum analyzer using a test fixture.

Test               Span                       RBW        VBW           Sweep           Detector   Trace       Instrument used
20 dB Bandwidth     150 kHz                   1.5 kHz    5.1 kHz       Auto            Peak       Max Hold    Spectrum Analyzer
99 % Occupied       Enough width to display   1 to 5 %   Three times   Auto            Peak       Max Hold    Spectrum Analyzer
Bandwidth           emission skirts           of OBW     of RBW
Peak hold was applied as Worst-case measurement.

Test data                           : APPENDIX
Test result                         : Pass




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                     Test report No.          : 12541448H-R1
                                                                     Page                     : 12 of 18
                                                                     Issued date              : January 31, 2019
                                                                     FCC ID                   : ACJ932IK3600F


APPENDIX 1: Test data

                                           Automatically deactivate

            Report No.                 12541448H
            Test place                 Ise EMC Lab.
            Semi Anechoic Chamber      No.4
            Date                       December 5, 2018
            Temperature / Humidity     23 deg. C / 48 % RH
            Engineer                   Ryota Yamanaka
            Mode                       Normal use mode

                              Time of                        Limit                 Result
                            Transmitting
                                [sec]                        [sec]
                               0.1583                        5.00                      Pass




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                                            Test report No.         : 12541448H-R1
                                                                                            Page                    : 13 of 18
                                                                                            Issued date             : January 31, 2019
                                                                                            FCC ID                  : ACJ932IK3600F


      Radiated Emission (Electric Field Strength of Fundamental and Spurious Emission)
               Report No.                      12541448H
               Test place                      Ise EMC Lab.
               Semi Anechoic Chamber           No.4                                  No.4
               Date                            December 5, 2018 (Day)                December 5, 2018 (Night)
               Temperature / Humidity          22 deg. C / 51 % RH                   23 deg. C / 53 % RH
               Engineer                        Hiroyuki Furutaka                     Ryota Yamanaka
                                               (Above 1GHz)                          (Below 1GHz)
               Mode                            Tx 433.92 MHz

PK
  Frequency     Detector     Reading          Ant     Loss     Gain     Duty            Result       Limit       Margin                 Remark
                             [dBuV]         Factor                      Factor        [dBuV/m]                    [dB]             Inside or Outside
   [MHz]                   Hor     Ver      [dB/m]    [dB]     [dB]      [dB]        Hor       Ver [dBuV/m]   Hor      Ver       of Restricted Bands
     433.920   PK           84.6     84.4      16.4     10.8     32.0            -    79.8      79.6  100.8    21.0     21.2   Carrier
     867.840   PK           38.0     30.3      22.0     13.0     31.4            -    41.6      33.9   80.8    39.2     46.9   Outside
    1301.760   PK           43.8     44.0      25.4      6.2     33.1            -    42.3      42.5   73.9    31.6     31.4   Inside
    1735.680   PK           49.5     48.0      25.3      5.8     32.0            -    48.6      47.1   80.8    32.2     33.7   Outside
    2169.600   PK           44.1     44.0      27.5      5.8     31.4            -    46.0      45.9   80.8    34.8     34.9   Outside
    2603.520   PK           47.9     46.5      28.2      6.0     31.2            -    50.9      49.5   80.8    29.9     31.3   Outside
    3037.440   PK           46.0     46.2      28.5      6.1     31.1            -    49.5      49.7   80.8    31.3     31.1   Outside
    3471.360   PK           45.1     44.9      29.0      6.3     30.9            -    49.5      49.3   80.8    31.3     31.5   Outside
    3905.280   PK           47.0     47.2      29.7      6.4     30.7            -    52.4      52.6   73.9    21.5     21.3   Inside
    4339.200   PK           45.5     45.0      30.4      6.7     30.7            -    51.9      51.4   73.9    22.0     22.5   Inside



PK with Duty factor
  Frequency     Detector     Reading          Ant     Loss     Gain     Duty            Result       Limit       Margin                  Remark
                             [dBuV]         Factor                      Factor        [dBuV/m]                    [dB]
   [MHz]                   Hor     Ver      [dB/m]    [dB]     [dB]      [dB]        Hor       Ver [dBuV/m]   Hor      Ver
     433.920   PK           84.6     84.4      16.4     10.8     32.0       0.0       79.8      79.6   80.8     1.0      1.2   Carrier
     867.840   PK           38.0     30.3      22.0     13.0     31.4       0.0       41.6      33.9   60.8    19.2     26.9   Outside
    1301.760   PK           43.8     44.0      25.4      6.2     33.1       0.0       42.3      42.5   53.9    11.6     11.4   Inside
    1735.680   PK           49.5     48.0      25.3      5.8     32.0       0.0       48.6      47.1   60.8    12.2     13.7   Outside
    2169.600   PK           44.1     44.0      27.5      5.8     31.4       0.0       46.0      45.9   60.8    14.8     14.9   Outside
    2603.520   PK           47.9     46.5      28.2      6.0     31.2       0.0       50.9      49.5   60.8     9.9     11.3   Outside
    3037.440   PK           46.0     46.2      28.5      6.1     31.1       0.0       49.5      49.7   60.8    11.3     11.1   Outside
    3471.360   PK           45.1     44.9      29.0      6.3     30.9       0.0       49.5      49.3   60.8    11.3     11.5   Outside
    3905.280   PK           47.0     47.2      29.7      6.4     30.7       0.0       52.4      52.6   53.9     1.5      1.3   Inside
    4339.200   PK           45.5     45.0      30.4      6.7     30.7       0.0       51.9      51.4   53.9     2.0      2.5   Inside



Sample calculation:
Result of PK = Reading + Ant Factor + Loss {Cable + Attenuator + Filter (above 1GHz) +Distance factor (above 1 GHz)} - Gain
(Amplifier)
Result of PK with Duty factor = Reading + Ant Factor + Loss {Cable + Attenuator + Filter (above 1 GHz) +Distance factor (above
1 GHz)} - Gain (Amplifier) + Duty factor (Refer to Duty factor data sheet)

For above 1GHz : Distance Factor: 20 x log (4.0 m/3.0 m) = 2.50 dB
*Other frequency noises omitted in this report were not seen or had enough margin (more than 20dB).

Since the peak emission result satisfied the average limit, duty factor was omitted.
Although Duty of this product was 100% or less, the result of AV (PK with Duty factor) was calculated by applying
Duty 100% as worst.




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                                                   Test report No.   : 12541448H-R1
                                                                                                   Page              : 14 of 18
                                                                                                   Issued date       : January 31, 2019
                                                                                                   FCC ID            : ACJ932IK3600F


                                                          Radiated Spurious Emission
                                                            (Plot data, Worst case)

            Report No.                                   12541448H
            Test place                                   Ise EMC Lab.
            Semi Anechoic Chamber                        No.4                            No.4
            Date                                         December 5, 2018 (Day)          December 5, 2018 (Night)
            Temperature / Humidity                       22 deg. C / 51 % RH             23 deg. C / 53 % RH
            Engineer                                     Hiroyuki Furutaka               Ryota Yamanaka
                                                         (Above 1GHz)                    (Below 1GHz)
            Mode                                         Tx 433.92 MHz



                                                                           Horizontal
                                              110
                                              100
                                              90
                    Field strength [dBuV/m]




                                              80
                                              70
                                              60
                                              50
                                              40
                                              30
                                              20
                                              10
                                                    10               100                         1000                10000
                                                                            Frequency [MHz]

                                                              Peak           Average          Average Limit



                                                                            Vertical
                                              110
                                              100
                                              90
                    Field strength [dBuV/m]




                                              80
                                              70
                                              60
                                              50
                                              40
                                              30
                                              20
                                              10
                                                    10               100                         1000                10000
                                                                            Frequency [MHz]

                                                              Peak           Average          Average Limit


          *These plots data contains sufficient number to show the trend of characteristic features for EUT.




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                              Test report No.       : 12541448H-R1
                                                                              Page                  : 15 of 18
                                                                              Issued date           : January 31, 2019
                                                                              FCC ID                : ACJ932IK3600F


                                     -20dB and 99% Occupied Bandwidth

            Report No.                   12541448H
            Test place                   Ise EMC Lab.
            Semi Anechoic Chamber        No.4
            Date                         December 5, 2018
            Temperature / Humidity       22 deg. C / 51 % RH
            Engineer                     Hiroyuki Furutaka
            Mode                         Tx 433.92 MHz


               Bandwidth Limit : Fundamental Frequency      433.92 MHz x 0.25% =         1084.80   kHz
                 * The above limit was calculated from more stringent nominal frequency.

                   -20dB Bandwidth             Bandwidth Limit           Result
                        [kHz]                      [kHz]
                       32.962                     1084.80                 Pass

               99% Occupied Bandwidth          Bandwidth Limit           Result
                       [kHz]                       [kHz]
                     32.3656                      1084.80                 Pass




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                            Test report No.          : 12541448H-R1
                                                                            Page                     : 16 of 18
                                                                            Issued date              : January 31, 2019
                                                                            FCC ID                   : ACJ932IK3600F


APPENDIX 2: Test instruments
Test Instruments
Test   LIMS     Description         Manufacturer      Model           Serial              Last             Calibration    Cal
item   ID                                                                                 Calibration      Due Date       Int
                                                                                          Date
RE     141545   DIGITAL             HIOKI             3805            51201148            1/9/2018         1/31/2019      12
                HiTESTER
RE     141508   Horn Antenna        Schwarzbeck       BBHA9120D       9120D-557           6/8/2018         6/30/2019      12
                1-18GHz
RE     141506   Horn Antenna        Schwarzbeck       BBHA9170        BBHA9170307         6/8/2018         6/30/2019      12
                15-40GHz
RE     142227   Measure             KOMELON           KMC-36          -                   -                -              -
RE     141581   MicroWave System    AGILENT           83017A          650                 10/4/2018        10/31/2019     12
                Amplifier
RE     141412   Microwave Cable     Junkosha          MWX221          1305S002R(1m) /     6/14/2018        6/30/2019      12
                                                                      1405S146(5m)
RE     142011   AC4_Semi Anechoic   TDK               Semi Anechoic   DA-10005            6/28/2018        6/30/2020      24
                Chamber(NSA)                          Chamber 3m
RE     141562   Thermo-Hygrometer   CUSTOM            CTH-180         1501                1/24/2018        1/31/2019      12
RE     141901   Spectrum Analyzer   AGILENT           E4440A          MY48250080          10/4/2018        10/31/2019     12
RE     141297   High Pass           TOKYO KEIKI       TF219CD1        1001                1/18/2018        1/31/2019      12
                Filter(1.1-10GHz)
RE     141152   EMI measurement     TSJ               TEPTO-DV        -                   -                -              -
                program
RE     142017   AC4_Semi Anechoic   TDK               Semi Anechoic   DA-10005            4/7/2018         4/30/2019      12
                Chamber(SVSWR)                        Chamber 3m
RE     141583   Pre Amplifier       SONOMA            310             260833              2/27/2018        2/28/2019      12
                                    INSTRUMENT
RE     141267   Logperiodic         Schwarzbeck       VUSLP9111B      911B-192            6/1/2018         6/30/2019      12
                Antenna(200-1000M
                Hz)
RE     141951   EMI Test Receiver   Rohde &           ESR26           101408              1/30/2018        1/31/2019      12
                                    Schwarz
RE     141397   Coaxial Cable       UL Japan          -               -                   6/13/2018        6/30/2019      12
RE     148898   Attenuator          KEYSIGHT          8491A           MY52462282          10/3/2018        10/31/2019     12
RE     141425   Biconical Antenna   Schwarzbeck       BBA9106         1302                6/1/2018         6/30/2019      12
RE     142645   Loop Antenna        UL Japan          -               -                   -                -              -

*Hyphens for Last Calibration Date, Calibration Due Date and Cal Int (month) are instruments that
Calibration is not required (e.g. software), or instruments checked in advance before use.

The expiration date of the calibration is the end of the expired month.
All equipment is calibrated with valid calibrations. Each measurement data is traceable to the national or
international standards.

As for some calibrations performed after the tested dates, those test equipment have been controlled by means
of an unbroken chains of calibrations.

Test item:
RE: Radiated emission, 99 % Occupied Bandwidth, -20 dB bandwidth, and Automatically deactivate tests




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124



Document Created: 2019-01-31 11:28:47
Document Modified: 2019-01-31 11:28:47

© 2024 FCC.report