RF Exposure Info (MPE)_rev2.pdf

FCC ID: A8J-EWS550AP

RF Exposure Info

Download: PDF
FCCID_3374633

                                                           RF Exposure Report

                       Report No.: SA160719C17B

                             FCC ID: A8J-EWS550AP

                              Model: EWS550AP

                 Received Date: Jul. 19, 2016

                         Test Date: Jul. 20 ~ Oct. 06, 2016

                     Issued Date: Dec. 20, 2016


                         Applicant: EnGenius Technologies

                          Address: 1580 Scenic Avenue, Costa Mesa, CA92626



                        Issued By: Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch

                    Lab Address: No. 47-2, 14th Ling, Chia Pau Vil., Lin Kou Dist., New Taipei City, Taiwan,
                                 R.O.C.
                  Test Location: No. 19, Hwa Ya 2nd Rd., Wen Hwa Vil., Kwei Shan Dist., Taoyuan City
                                 33383, TAIWAN (R.O.C.)




This report is for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted
only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this
report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product
unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you
provided to us. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence, provided,
however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time
shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Unless specific
mention, the uncertainty of measurement has been explicitly taken into account to declare the compliance or non-compliance to the specification.
The report must not be used by the client to claim product certification, approval, or endorsement by TAF or any government agencies.


Report No.: SA160719C17B                                             Page No. 1 / 6                                             Report Format Version: 6.1.1
Reference No.: 160719C17, 161216C03


                                                                   Table of Contents
Release Control Record .................................................................................................................................. 3
1         Certificate of Conformity...................................................................................................................... 4
2         RF Exposure .......................................................................................................................................... 5
    2.1      Limits for Maximum Permissible Exposure (MPE) .............................................................................. 5
    2.2      MPE Calculation Formula ................................................................................................................... 5
    2.3      Classification ....................................................................................................................................... 5
3         Calculation Result of Maximum Conducted Power........................................................................... 6




Report No.: SA160719C17B                                             Page No. 2 / 6                                              Report Format Version: 6.1.1
Reference No.: 160719C17, 161216C03


                                          Release Control Record


Issue No.              Description                                        Date Issued
SA160719C17B           Original release                                   Dec. 20, 2016




Report No.: SA160719C17B                     Page No. 3 / 6        Report Format Version: 6.1.1
Reference No.: 160719C17, 161216C03


1    Certificate of Conformity


            Product: Wireless AC1300 Managed Wall Plate Access Point

              Brand: EnGenius

              Model: EWS550AP

    Sample Status: Engineering sample

          Applicant: EnGenius Technologies

          Test Date: Jul. 20 ~ Oct. 06, 2016

         Standards: FCC Part 2 (Section 2.1091)
                        KDB 447498 D03 (January 17, 2014)
                        IEEE C95.1



The above equipment has been tested by Bureau Veritas Consumer Products Services (H.K.) Ltd.,
Taoyuan Branch, and found compliance with the requirement of the above standards. The test record, data
evaluation & Equipment Under Test (EUT) configurations represented herein are true and accurate accounts
of the measurements of the sample’s EMC characteristics under the conditions specified in this report.




      Prepared by :                                              , Date:        Dec. 20, 2016
                             Pettie Chen / Senior Specialist




     Approved by :                                               , Date:        Dec. 20, 2016
                                Ken Liu / Senior Manager




Report No.: SA160719C17B                        Page No. 4 / 6                       Report Format Version: 6.1.1
Reference No.: 160719C17, 161216C03


2     RF Exposure
2.1     Limits for Maximum Permissible Exposure (MPE)

    Frequency Range          Electric Field     Magnetic Field       Power Density         Average Time
         (MHz)              Strength (V/m)      Strength (A/m)         (mW/cm2)              (minutes)
                             Limits For General Population / Uncontrolled Exposure
       300-1500                   …                    …                  F/1500                  30
      1500-100,000                …                    …                   1.0                    30
F = Frequency in MHz


2.2     MPE Calculation Formula
Pd = (Pout*G) / (4*pi*r2)
where
Pd = power density in mW/cm2
Pout = output power to antenna in mW
G = gain of antenna in linear scale
Pi = 3.1416
R = distance between observation point and center of the radiator in cm


2.3     Classification
The antenna of this product, under normal use condition, is at least 20cm away from the body of the user. So,
this device is classified as Mobile Device.




Report No.: SA160719C17B                       Page No. 5 / 6                        Report Format Version: 6.1.1
Reference No.: 160719C17, 161216C03


3     Calculation Result of Maximum Conducted Power
Frequency Band         Max Power         Antenna Gain             Distance      Power Density             Limit
    (MHz)                (dBm)               (dBi)                  (cm)          (mW/cm2)              (mW/cm2)
                                           WLAN 2.4GHz: CDD mode

     2412-2462            23.44               7.01                  20              0.221                    1

                                       WLAN 2.4GHz: Beamforming mode

     2412-2462            21.48               7.01                  20              0.141                    1

                                            WLAN 5GHz: CDD mode

     5180-5240            23.05               8.87                  20              0.310                    1

     5745-5825            22.92               8.87                  20              0.300                    1

                                        WLAN 5GHz: Beamforming mode

     5180-5240            22.86               8.87                  20              0.296                    1

     5745-5825            23.12               8.87                  20              0.315                    1

                                                         BT LE

     2402-2480             2.95               3.51                  20              0.001                    1

                                                         Zigbee

     2405-2480             3.25               3.51                  20              0.001                    1
Note:
2.4GHz Band: Directional gain = 10 log[(10G1 /20 + 10G2 /20 + ... + 10GN /20)2/2]= 7.01dBi
5GHz Band: Directional gain = 10 log[(10G1 /20 + 10G2 /20 + ... + 10GN /20)2/2]= 8.87 dBi

                                          Max Power (dBm)                           Total Power         Power Limit
    Frequency Band
                             WLAN                BT LE                Zigbee          (dBm)               (dBm)

       2.4GHz                23.44                2.95                    -            23.48                 30
       2.4GHz                23.44                   -                   3.25          23.48                 30
Conclusion:
The WLAN 2.4G & WLAN 5G & BT LE & Zigbee can transmit simultaneously, the formula of calculated the
MPE is:
CPD1 / LPD1 + CPD2 / LPD2 + ……etc. < 1
CPD = Calculation power density
LPD = Limit of power density

1. WALN 2.4GHz + WALN 5GHz + BT LE
= 0.221 + 0.315 + 0.001 = 0.537
2. WALN 2.4GHz + WALN 5GHz + Zigbee
= 0.221 + 0.315 + 0.001 = 0.537


Therefore the maximum calculations of above situations are less than the “1” limit.