RF Exposure Info (MPE)

FCC ID: A8J-EWS377AP

RF Exposure Info

Download: PDF
FCCID_4228840

                                                           RF Exposure Report

                       Report No.: SA190211C24 R1

                             FCC ID: A8J-EWS377AP

                       Test Model: EWS377AP

                  Series Model: ECW630

                 Received Date: Feb. 04, 2019

                         Test Date: Feb. 04 ~ Mar. 05, 2019

                     Issued Date: Apr. 02, 2019



                         Applicant: EnGenius Technologies

                          Address: 1580 Scenic Avenue, Costa Mesa, CA92626



                        Issued By: Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch

                    Lab Address: No. 47-2, 14th Ling, Chia Pau Vil., Lin Kou Dist., New Taipei City, Taiwan,
                                 R.O.C.
                  Test Location: No. 19, Hwa Ya 2nd Rd., Wen Hwa Vil., Kwei Shan Dist., Taoyuan City
                                 33383, TAIWAN (R.O.C.)




This report is for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted
only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this
report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product
unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you
provided to us. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence, provided,
however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time
shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Unless specific
mention, the uncertainty of measurement has been explicitly taken into account to declare the compliance or non-compliance to the specification.
The report must not be used by the client to claim product certification, approval, or endorsement by TAF or any government agencies.


Report No.: SA190211C24 R1                            Page No. 1 / 6                                                            Report Format Version: 6.1.1
Cancels and replaces the report No.: SA190211C24 dated Mar. 18, 2019


                                                                   Table of Contents
Release Control Record .................................................................................................................................. 3
1         Certificate of Conformity...................................................................................................................... 4
2         RF Exposure .......................................................................................................................................... 5
    2.1      Limits for Maximum Permissible Exposure (MPE) .............................................................................. 5
    2.2      MPE Calculation Formula ................................................................................................................... 5
    2.3      Classification ....................................................................................................................................... 5
3         Calculation Result of Maximum Conducted Power........................................................................... 6




Report No.: SA190211C24 R1                            Page No. 2 / 6                                                             Report Format Version: 6.1.1
Cancels and replaces the report No.: SA190211C24 dated Mar. 18, 2019


                                                Release Control Record


Issue No.               Description                                             Date Issued
SA190211C24             Original release.                                       Mar. 18, 2019
SA190211C24 R1          Revised product name.                                   Apr. 02, 2019




Report No.: SA190211C24 R1                            Page No. 3 / 6     Report Format Version: 6.1.1
Cancels and replaces the report No.: SA190211C24 dated Mar. 18, 2019


1    Certificate of Conformity


             Product: 802.11AX Indoor Ceiling Mount Access Point

               Brand:


         Test Model: EWS377AP

       Series Model: ECW630

     Sample Status: Engineering sample

           Applicant: EnGenius Technologies

           Test Date: Feb. 04 ~ Mar. 05, 2019

          Standards: FCC Part 2 (Section 2.1091)
                          KDB 447498 D01 General RF Exposure Guidance v06
                          IEEE C95.1



The above equipment has been tested by Bureau Veritas Consumer Products Services (H.K.) Ltd.,
Taoyuan Branch, and found compliance with the requirement of the above standards. The test record, data
evaluation & Equipment Under Test (EUT) configurations represented herein are true and accurate accounts
of the measurements of the sample’s RF characteristics under the conditions specified in this report.




      Prepared by :                                                    , Date:   Apr. 02, 2019
                               Pettie Chen / Senior Specialist




     Approved by :                                                     , Date:   Apr. 02, 2019
                               Bruce Chen / Project Engineer




Report No.: SA190211C24 R1                            Page No. 4 / 6                  Report Format Version: 6.1.1
Cancels and replaces the report No.: SA190211C24 dated Mar. 18, 2019


2     RF Exposure
2.1     Limits for Maximum Permissible Exposure (MPE)

    Frequency Range           Electric Field          Magnetic Field   Power Density         Average Time
         (MHz)               Strength (V/m)           Strength (A/m)     (mW/cm2)              (minutes)
                               Limits For General Population / Uncontrolled Exposure
        0.3-1.34                   614                      1.63           (100)*                   30
                                                                                   2
        1.34-30                    824/f                    2.19/f        (180/f )*                 30
        30-300                     27.5                     0.073            0.2                    30
       300-1500                     …                         …            f/1500                   30
      1500-100,000                  …                         …              1.0                    30

f = Frequency in MHz; *Plane-wave equivalent power density



2.2     MPE Calculation Formula
Pd = (Pout*G) / (4*pi*r2)
where
Pd = power density in mW/cm2
Pout = output power to antenna in mW
G = gain of antenna in linear scale
pi = 3.1416
r = distance between observation point and center of the radiator in cm


2.3     Classification
The antenna of this product, under normal use condition, is at least 25cm away from the body of the user. So,
this device is classified as Mobile Device.




Report No.: SA190211C24 R1                            Page No. 5 / 6                   Report Format Version: 6.1.1
Cancels and replaces the report No.: SA190211C24 dated Mar. 18, 2019


3    Calculation Result of Maximum Conducted Power

Frequency Band           Max Power          Antenna Gain               Distance   Power Density           Limit
    (MHz)                  (dBm)                (dBi)                    (cm)       (mW/cm2)            (mW/cm2)
CDD Mode
    2412-2462               26.25                 9.12                   25          0.438                   1

    5180-5240               25.61                10.32                   25          0.499                   1

    5745-5825               26.10                10.32                   25          0.558                   1

Beamforming Mode
    2412-2462               19.88                 9.12                   25          0.101                   1

    5180-5240               19.59                10.32                   25          0.125                   1

    5745-5825               20.05                10.32                   25          0.139                   1
*Determining compliance based on the results of the compliance measurement, not taking into account
measurement instrumentation uncertainty.

Note:
2.4GHz Band: Directional Gain = 3.10dBi+ 10log(4) = 9.12dBi
5GHz Band: Directional Gain = 4.30dBi + 10log(4) = 10.32dBi

Conclusion:
2.4GHz & 5GHz can transmit at same time.
The formula of calculated the MPE is:
CPD1 / LPD1 + CPD2 / LPD2 + ……etc. < 1
CPD = Calculation power density
LPD = Limit of power density

WLAN 2.4GHz + WLAN 5GHz = 0.438 + 0.558 = 0.996


Therefore the maximum calculations of above situations are less than the “1” limit.




---END---




Report No.: SA190211C24 R1                            Page No. 6 / 6                         Report Format Version: 6.1.1
Cancels and replaces the report No.: SA190211C24 dated Mar. 18, 2019



Document Created: 2019-04-08 20:31:58
Document Modified: 2019-04-08 20:31:58

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC