test report

FCC ID: A6N-341RX

Test Report

Download: PDF
FCCID_1857171

        CENTRE OF TESTING SERVICE
             INTERNATIONAL

      OPERATE ACCORDING TO ISO/IEC 17025




      FCC ID/IC
    TEST REPORT
TEST REPORT NUMBER : CGZ3121113-00911-EFI




                  CENTRE OF TESTING SERVICE CO., LTD.
        Building F, Dachuang industrial park, No.379, Zhongshan Dadao,
                            Guangzhou, China.


    FCC ID:A6N-341RX




                                                                   TEST REPORT For FCC ID/IC

                                                                   47 CFR PART 15 OCT, 2011
                                                                        RSS-Gen Issue 3
       Report Reference No. .................... CGZ3121113-00911-EFI
       Date of issue..................................... 29 November 2012
       Testing Laboratory Name .............. CENTRE OF TESTING SERVICE CO., LTD.
       Address............................................. Building F, Dachuang industrial park, No.379, Zhongshan Dadao,
                                                            Guangzhou, China.
       Testing location/ procedure .............. Full application of Harmonised standards ■
                                                                     Partial application of Harmonised standards □
                                                                     Other standard testing method □
       Applicant’s name............................ Thermor Ltd.
       Address............................................. 16975 Leslie Street , Newmarket, ON L3Y 9A1
       Test specification ...........................
       Standard ........................................... 47 CFR PART 15 OCT, 2011, ANSI C63.4-2009,
                                                                     RSS-Gen Issue 3
       Test Report Form No. .................... CTSEMC-1.0
       TRF Originator .................................. CENTRE OF TESTING SERVICE CO., LTD.
       Master TRF....................................... Dated 2009-01
       CENTRE OF TESTING SERVICE CO., LTD. All rights reserved.
       This publication may be reproduced in whole or in part for non-commercial purposes as long as the
       CENTRE OF TESTING SERVICE CO., LTD is acknowledged as copyright owner and source of the
       material. CENTRE OF TESTING SERVICE CO., LTD takes no responsibility for and will not assume liability
       for damages resulting from the reader's interpretation of the reproduced material due to its placement and
       context.
       Test item description .................... 5 DAY WEATHER FORECASTING STATION
       Trade Mark ....................................... /
       Manufacturer..................................... FUZHOU EVERTOP ELECTRONIC CO.,LTD.
       Model/Type reference....................... 341NC
       Ratings.............................................. Battery 1.5V*2
       Operating Frequency........................ 433.92 MHz (RX)
       Result ............................................... PASSED

                   Compiled by:                                                     Supervised by:                                                    Approved by:



          Kate zhang / Fileadministrators                                   Duke yang / Technique principal                                        Vincent yao / Manager




opyright of this report is owned by Centre of Testing Service and may not be reproduced other than in full except with the written approval of the issuing Company.


CENTRE OF TESTING SERVICE CO., LTD.
Building F, Dachuang industrial park, No.379, Zhongshan Dadao, Guangzhou, China
Tel:+86-20-85543113 (32 lines)                 Fax:+86-20-38780406
Complaint line:+86-20-85533471                 E-mail:cts@cts-lab.com.cn                         See Reverse For Terms And Conditions of Service


Report No.: CGZ3121113-00911-EFI                                                                                                                                 Page 1 of 17


    FCC ID:A6N-341RX




                                                FCC ID -- T E S T R E P O R T
                                                                                                                                                   29 November 2012
        Test Report No. :                                       CGZ3121113-00911-EFI                                                                  Date of issue


        Type / Model............................                341NC, 341NU,341BC, 341BU

        EUT..........................................           5 DAY WEATHER FORECASTING STATION

        Applicant………………………                                      Thermor Ltd.
        Address....................................             16975 Leslie Street , Newmarket, ON L3Y 9A1
        Telephone................................               +800-3878520
        Fax...........................................          +886-9471034
        Contact.....................................            Joanna Biniek

        Manufacturer………………….                                    FUZHOU EVERTOP ELECTRONIC CO.,LTD.
        Address....................................             No.46,Bai Hua Zhou Rd, Pushang Industrial Area, Fuzhou, Fujian, China
        Telephone................................               + 86-591-83742688
        Fax...........................................          + 86-591-83766488
        Contact.....................................            Nancy


        Factory ……………………….                                      FUZHOU EVERTOP ELECTRONIC CO.,LTD.
        Address....................................             No.46,Bai Hua Zhou Rd, Pushang Industrial Area, Fuzhou, Fujian, China
        Telephone................................               + 86-591-83742688
        Fax...........................................          + 86-591-83766488
        Contact.....................................            Nancy


          The test report merely corresponds to the test sample.
          It is not permitted to copy extracts of these test result without the written permission of the test laboratory.




opyright of this report is owned by Centre of Testing Service and may not be reproduced other than in full except with the written approval of the issuing Company.


CENTRE OF TESTING SERVICE CO., LTD.
Building F, Dachuang industrial park, No.379, Zhongshan Dadao, Guangzhou, China
Tel:+86-20-85543113 (32 lines)                 Fax:+86-20-38780406
Complaint line:+86-20-85533471                 E-mail:cts@cts-lab.com.cn                         See Reverse For Terms And Conditions of Service


Report No.: CGZ3121113-00911-EFI                                                                                                                                 Page 2 of 17


    FCC ID:A6N-341RX




                                                                    TABLE OF CONTENTS
Description                                                                                                                                                                 Page

1. TEST STANDARDS.......................................................................................................................................4


2. SUMMARY ....................................................................................................................................................4

     2.1 GENERAL REMARKS.......................................................................................................................................4
     2.2 FINAL ASSESSMENT .......................................................................................................................................4

3. EQUIPMENT UNDER TEST..........................................................................................................................5

     3.1 POWER SUPPLY SYSTEM UTILISED .........................................................................................................................5
     3.2 SHORT DESCRIPTION OF THE EQUIPMENT UNDER TEST (EUT) ................................................................................5
     3.3 EUT OPERATION MODE .........................................................................................................................................5
     3.4 EUT CONFIGURATION ...........................................................................................................................................6

4. TEST ENVIRONMENT ..................................................................................................................................7

     4.1 ADDRESS OF THE TEST LABORATORY ....................................................................................................................7
     4.2 TEST FACILITY ......................................................................................................................................................7
     4.3 ENVIRONMENTAL CONDITIONS ...............................................................................................................................7
     4.4 DEFINITIONS OF SYMBOLS USED IN THIS TEST REPORT ............................................................................................7
     4.5 STATEMENT OF THE MEASUREMENT UNCERTAINTY .................................................................................................7
     4.6 MEASUREMENT UNCERTAINTY...............................................................................................................................8

5. Summary of standards and results ............................................................................................................8

     5.1.DESCRIPTION OF STANDARDS AND RESULTS .........................................................................................................8

6. Power Line Conducted Emission Test .......................................................................................................9

     6.1.1 DESCRIPTION OF THE TEST LOCATION .................................................................................................................9
     6.1.2TEST EQUIPMENT................................................................................................................................................9
     6.2.1 BLOCK DIAGRAM OF TEST SETUP ......................................................................................................................9
     6.2.2 DESCRIPTION OF THE TEST SET-UP .....................................................................................................................9
     6.2.3 LIMITS OF DISTURBANCE (CLASS B) .................................................................................................................10
     6.2.4 POWER LINE CONDUCTED EMISSION TEST RESULTS .........................................................................................10

7. Radiated disturbance (electric field) ........................................................................................................11

     7.1.TEST EQUIPMENT................................................................................................................................................11
     7.2.BLOCK DIAGRAM OF TEST SETUP .......................................................................................................................11
     7.3.RADIATED EMISSION LIMIT STANDARD: FCC 109................................................................................................12
     7.4.TEST PROCEDURE ..............................................................................................................................................12
     7.5.RADIATED EMISSION TEST RESULTS ...................................................................................................................13

8. Manufacturer/ Approval holder Declaration ............................................................................................17


opyright of this report is owned by Centre of Testing Service and may not be reproduced other than in full except with the written approval of the issuing Company.


CENTRE OF TESTING SERVICE CO., LTD.
Building F, Dachuang industrial park, No.379, Zhongshan Dadao, Guangzhou, China
Tel:+86-20-85543113 (32 lines)                 Fax:+86-20-38780406
Complaint line:+86-20-85533471                 E-mail:cts@cts-lab.com.cn                         See Reverse For Terms And Conditions of Service


Report No.: CGZ3121113-00911-EFI                                                                                                                                 Page 3 of 17


    FCC ID:A6N-341RX




         1. TEST STANDARDS
           The tests were performed according to following standards:

           ■47 CFR PART 15 OCT, 2011
           ■ ANSI C63.4-2009
           ■ RSS-Gen Issue 3


         2. SUMMARY
     2.1 GENERAL REMARKS
              Date of receipt of test sample                          15 November 2012

              Testing commenced on                                    16 November 2012

              Testing concluded on                                    29 November 2012
     2.2 FINAL ASSESSMENT
           The FCC requirements pertaining to the technical standards and tested operation modes are

          ■               - fulfilled.

          □               - not fulfilled.

          The equipment under test

          ■               - fulfils the FCC requirements cited on page 1.

          □               - does not fulfil the FCC requirements cited on page 1.




opyright of this report is owned by Centre of Testing Service and may not be reproduced other than in full except with the written approval of the issuing Company.


CENTRE OF TESTING SERVICE CO., LTD.
Building F, Dachuang industrial park, No.379, Zhongshan Dadao, Guangzhou, China
Tel:+86-20-85543113 (32 lines)                 Fax:+86-20-38780406
Complaint line:+86-20-85533471                 E-mail:cts@cts-lab.com.cn                         See Reverse For Terms And Conditions of Service


Report No.: CGZ3121113-00911-EFI                                                                                                                                 Page 4 of 17


    FCC ID:A6N-341RX




         3. EQUIPMENT UNDER TEST
     3.1 Power supply system utilised
            Power supply voltage                     :          ■ Battery 1.5V*2
                                                                □ Other


     3.2 Short description of the Equipment under Test (EUT)
     Number of tested samples: 1
     Serial number:            Prototype
     EUT type:                 Receiver
     3.3 EUT operation mode
     The equipment under test was operated during the measurement under the following conditions:
     For Radiation emission:
     ■ –RX



     Operation mode 1: RX
     Note: X position of EUT is the worst case, so only these test results be recorded in the test report.




opyright of this report is owned by Centre of Testing Service and may not be reproduced other than in full except with the written approval of the issuing Company.


CENTRE OF TESTING SERVICE CO., LTD.
Building F, Dachuang industrial park, No.379, Zhongshan Dadao, Guangzhou, China
Tel:+86-20-85543113 (32 lines)                 Fax:+86-20-38780406
Complaint line:+86-20-85533471                 E-mail:cts@cts-lab.com.cn                         See Reverse For Terms And Conditions of Service


Report No.: CGZ3121113-00911-EFI                                                                                                                                 Page 5 of 17


    FCC ID:A6N-341RX




     3.4 EUT configuration
             3.4.1. Description of configuration (EUT)

                             Description                                    :      5 DAY WEATHER FORECASTING STATION
                             Model Number                                   :      341NC
                             Operation frequency                            :      433.92MHz
                             Radio Technology                               :      FSK
                             Modulation Technology                          :      FSK modulation
                             Antenna                                        :      Internal Antenna

             3.4.2. Tested Supporting System Details
                    Not Applicable.




opyright of this report is owned by Centre of Testing Service and may not be reproduced other than in full except with the written approval of the issuing Company.


CENTRE OF TESTING SERVICE CO., LTD.
Building F, Dachuang industrial park, No.379, Zhongshan Dadao, Guangzhou, China
Tel:+86-20-85543113 (32 lines)                 Fax:+86-20-38780406
Complaint line:+86-20-85533471                 E-mail:cts@cts-lab.com.cn                         See Reverse For Terms And Conditions of Service


Report No.: CGZ3121113-00911-EFI                                                                                                                                 Page 6 of 17


    FCC ID:A6N-341RX




         4. TEST ENVIRONMENT

     4.1 Address of the test laboratory
     Building F, Dachuang industrial park, No.379, Zhongshan Dadao, Guangzhou, China

     Tel:+86-20-85543113                        (32 lines)                         Fax:+86-20-38780406

     4.2 Test facility
     The test facility is recognized, certified, or accredited by the following organizations:
    CNAS-Lab Code: L3394
     CENTRE OF TESTING SERVICE CO., LTD has been assessed and proved to be in
     compliance with CNAS-CL01: 2006 Accreditation Criteria for Testing and Calibration
     Laboratories (identical to ISO/IEC 17025: 2005 General Requirements) for the Competence of
     Testing and Calibration Laboratories.
    IC-Registration No.: 8374A
    The 3m Alternate Test Site of CENTRE OF TESTING SERVICE CO., LTD has been registered by Certification
    and Engineering Bureau of Industry Canada for the performance of radiated measurements with Registration No.
    8374A on June 6, 2011 .
    FCC-Registration No.: 971995
     CENTRE OF TESTING SERVICE CO., LTD, EMC Laboratory has been registered
     and fully described in a report filed with the FCC (Federal Communications Commission). The
     acceptance letter from the FCC is maintained in our files. Registration No.791995, July 13, 2012.

     4.3 Environmental conditions
     During the measurement the environmental conditions were within the listed ranges:
                    Temperature:                                      15~35 ° C

                    Humidity:                                         25~75 %

                    Atmospheric pressure:                             86~106 kPa

     4.4 Definitions of symbols used in this test report
      ■ - The black square indicates that the listed condition, standard or equipment is applicable for this report.
      □ - The empty square indicates that the listed condition, standard or equipment is not applicable for this report.

     4.5 Statement of the measurement uncertainty
     The data and results referenced in this document are true and accurate. The reader is cautioned that there may
     be errors within the calibration limits of the equipment and facilities. The measurement uncertainty was
     calculated for all measurements listed in this test report acc. to CISPR 16 - 4 “Specification for radio
     disturbance and immunity measuring apparatus and methods – Part 4: Uncertainty in EMC Measurements” and
     is documented in the CTS quality system acc. to DIN EN ISO/IEC 17025. Furthermore, component and process
     variability of devices similar to that tested may result in additional deviation. The manufacturer has the sole
     responsibility of continued compliance of the device.


opyright of this report is owned by Centre of Testing Service and may not be reproduced other than in full except with the written approval of the issuing Company.


CENTRE OF TESTING SERVICE CO., LTD.
Building F, Dachuang industrial park, No.379, Zhongshan Dadao, Guangzhou, China
Tel:+86-20-85543113 (32 lines)                 Fax:+86-20-38780406
Complaint line:+86-20-85533471                 E-mail:cts@cts-lab.com.cn                         See Reverse For Terms And Conditions of Service


Report No.: CGZ3121113-00911-EFI                                                                                                                                 Page 7 of 17


    FCC ID:A6N-341RX




     4.6 Measurement Uncertainty

                              Test Item                                       Frequency Range                                           Uncertainty                         Note
                  Conduction disturbance                                        150kHz~30MHz                                              ±1.22dB                           (1)
                     Power disturbance                                         30MHz~300MHz                                               ±1.38dB                           (1)
                                                                               30MHz~300MHz                                               ±3.14dB                           (1)
                     Radiation emission (3m)
                                                                             300MHz~1000MHz                                               ±3.18dB                           (1)
                                                     1GHz~18GHz                      ±3.54dB             (1)
          (1) .This uncertainty represents an expanded uncertainty expressed at approximately the 95% confidence
               level using a coverage factor of k=2.


         5. Summary of standards and results
     5.1.Description of Standards and Results
               The EUT have been tested according to the applicable standards as referenced below.
                                                                                           EMISSION

                              Description of Test Item                                                        Standard                                          Results

                                                                                                         ANSI C63.4-2009
                                Conducted Emission Test                                            FCC Part 15 B: 15.107                                              N/A
                                                                                                     RSS-Gen:7.2.4
                                                                                                         ANSI C63.4-2009
                                  Radiated Emission Test                                              FCC Part 15 B: 109                                        PASSED
                                                                                                           RSS-Gen:4.10

                N/A is an abbreviation for Not Applicable.




opyright of this report is owned by Centre of Testing Service and may not be reproduced other than in full except with the written approval of the issuing Company.


CENTRE OF TESTING SERVICE CO., LTD.
Building F, Dachuang industrial park, No.379, Zhongshan Dadao, Guangzhou, China
Tel:+86-20-85543113 (32 lines)                 Fax:+86-20-38780406
Complaint line:+86-20-85533471                 E-mail:cts@cts-lab.com.cn                         See Reverse For Terms And Conditions of Service


Report No.: CGZ3121113-00911-EFI                                                                                                                                 Page 8 of 17


    FCC ID:A6N-341RX




         6. Power Line Conducted Emission Test
     6.1.1 Description of the test location


               Test location              :    Shielding Room

     6.1.2Test Equipment
          Conducted Disturbance
           Item     Test Equipment                                    Manufacturer                               Model No.                 Serial No.                 Last Cal.
             1    EMI Test Receiver                                ROHDE & SCHWARZ                               ESHS10                   842884/012                  2011/12
             2      Artificial Mains                               ROHDE & SCHWARZ                               ESH3-Z5                  832479/025                  2011/12
             3      Artificial Mains                               ROHDE & SCHWARZ                               ESH3-Z5                  832479/026                  2011/12
             4       Pulse Limiter                                 ROHDE & SCHWARZ                               ESHSZ2                     100301                    2011/12
             5    EMI Test Software                                ROHDE & SCHWARZ                                ESK1                       N/A                      2011/12
     6.2.1 Block Diagram of Test Setup




                                                                                  EUT(RX)



                                                    (EUT: 5 DAY WEATHER FORECASTING STATION)
     6.2.2 Description of the test set-up
                  6.1.2.1 Operating Condition

                  The EUT is engraving during the test, and the results of the maximum emanation are recorded

                  6.1.2.2 Block Diagram of Test Setup




opyright of this report is owned by Centre of Testing Service and may not be reproduced other than in full except with the written approval of the issuing Company.


CENTRE OF TESTING SERVICE CO., LTD.
Building F, Dachuang industrial park, No.379, Zhongshan Dadao, Guangzhou, China
Tel:+86-20-85543113 (32 lines)                 Fax:+86-20-38780406
Complaint line:+86-20-85533471                 E-mail:cts@cts-lab.com.cn                         See Reverse For Terms And Conditions of Service


Report No.: CGZ3121113-00911-EFI                                                                                                                                 Page 9 of 17


    FCC ID:A6N-341RX



     6.2.3 Limits of disturbance (Class B)
                                                                                              Maximum RF Line Voltage
                                    Frequency                                       Quasi-Peak Level            Average Level
                                                                                        dB(μV)                       dB(μV)
                           150kHz                ~ 500kHz                              66 ~ 56*                     56 ~ 46*
                           500kHz                ~ 5MHz                                    56                          46
                            5MHz                 ~ 30MHz                                   60                          50

                  Note: (1) The tighter limit shall apply at the edge between two frequency bands.



     6.2.4 Power Line Conducted Emission Test Results


             Test Result: N/A (Note: The EUT is power supply by battery.)




opyright of this report is owned by Centre of Testing Service and may not be reproduced other than in full except with the written approval of the issuing Company.


CENTRE OF TESTING SERVICE CO., LTD.
Building F, Dachuang industrial park, No.379, Zhongshan Dadao, Guangzhou, China
Tel:+86-20-85543113 (32 lines)                 Fax:+86-20-38780406
Complaint line:+86-20-85533471                 E-mail:cts@cts-lab.com.cn                         See Reverse For Terms And Conditions of Service


Report No.: CGZ3121113-00911-EFI                                                                                                                                 Page 10 of 17


    FCC ID:A6N-341RX




         7. Radiated disturbance (electric field)
     7.1.Test Equipment
                   Radiated disturbance (electric field)
                   Item           Test Equipment                              Manufacturer                        Model No.                     Serial No.            Last Cal.
                   1           EMI Test Receiver                   ROHDE & SCHWARZ                                ESCI                            100868              2011/12
                   2           Biconical Antenna                   ROHDE & SCHWARZ                                HK116                           100221              2011/12
                   3           Log per Antenna                     ROHDE & SCHWARZ                                HL223                           100226              2011/12
                   4           Log per Antenna                     ROHDE & SCHWARZ                                HL050                           100186              2011/12
                   5           Signal analyzer                     ROHDE & SCHWARZ                                FSIQ26                          100311              2011/12
                   6           Loop Antenna                        A.R.A                                          PLA-1030/B                        1030              2011/12

     7.2.Block Diagram of Test Setup
                          7.2.1 Block Diagram of connection between EUT and simulators




                                                                                          EUT( RX)




                                                                                                                                                                 Wood Table




                                                 (EUT:5 DAY WEATHER FORECASTING STATION)
                          7.2.2 Anechoic Chamber Setup Diagram




opyright of this report is owned by Centre of Testing Service and may not be reproduced other than in full except with the written approval of the issuing Company.


CENTRE OF TESTING SERVICE CO., LTD.
Building F, Dachuang industrial park, No.379, Zhongshan Dadao, Guangzhou, China
Tel:+86-20-85543113 (32 lines)                 Fax:+86-20-38780406
Complaint line:+86-20-85533471                 E-mail:cts@cts-lab.com.cn                         See Reverse For Terms And Conditions of Service


Report No.: CGZ3121113-00911-EFI                                                                                                                                 Page 11 of 17


    FCC ID:A6N-341RX




     7.3.Radiated Emission Limit Standard: FCC 109
                               FREQUENCY                                            DISTANCE
                                                                                         FIELD STRENGTHS LIMIT
                                  MHz                                                     μV/m
                                                                                      Meters                dB(μV)/m
                            30      ~     88                                            3  100                 40.0
                            88      ~    216                                            3  150                 43.5
                           216      ~    960                                            3  200                 46.0
                           960      ~   1000                                            3  500                 54.0
                                                                                         Other:74.0 dB(μV)/m (Peak)
                               Above 1000                        3
                                                                                          54.0 dB(μV)/m (Average)
                            Remark: (1) Emission level dBμV = 20 log Emission level μV/m
                                    (2) The smaller limit shall apply at the cross point between two frequency bands.
                                    (3) Distance is the distance in meters between the measuring instrument, antenna and
                                     the closest point of any part of the device or system.
      7.4.Test Procedure
             The EUT and its simulators are placed on a turn table, which is 0.8 meter high above ground. The turn table
             can rotate 360 degrees to determine the position of the maximum emission level. The EUT is set 3 meters
             away from the receiving antenna, which is mounted on a antenna tower. The antenna can be moved up and
             down between 1 meter and 4 meters to find out the maximum emission level. Broadband antenna
             (calibrated bilog antenna) is used as receiving antenna. Both horizontal and vertical polarization of the
             antenna is set on Test. In order to find the maximum emission levels, all of the interface cables must be
             manipulated according to ANSI C63.4-2009on radiated emission Test.
             The frequency range from 30MHz to 1000MHz and above 1GHz. is investigated. Please see the following
             pages.
             All measurements for radiated emissions within the restricted bands were performed using a Quasi-Peak
             detector with 120kHz RBW below 1GHz and a Peak and Average detector with 1MHz RBW above 1GHz,

             All measurements for radiated emissions within the restricted bands were performed using a Quasi-Peak
             detector with 300kHz VBW below 1GHz and a Peak detector with 1MHz VBW above 1GHz, Pretest of EUT,
             final, select the worst case test and record the test results in the report.

             The test modes is tested in Anechoic Chamber and all the scanning waveforms are reported on section 7.5



opyright of this report is owned by Centre of Testing Service and may not be reproduced other than in full except with the written approval of the issuing Company.


CENTRE OF TESTING SERVICE CO., LTD.
Building F, Dachuang industrial park, No.379, Zhongshan Dadao, Guangzhou, China
Tel:+86-20-85543113 (32 lines)                 Fax:+86-20-38780406
Complaint line:+86-20-85533471                 E-mail:cts@cts-lab.com.cn                         See Reverse For Terms And Conditions of Service


Report No.: CGZ3121113-00911-EFI                                                                                                                                 Page 12 of 17


    FCC ID:A6N-341RX




     7.5.Radiated Emission Test Results
             PASSED.

                    Channel:                                  433.92 MHz (RX)                                             Result:          ■ - passed
                    Test point:                               Horizontal                                                                   □ - not passed
                    Frequency range:                          30MHz-18GHz

                    EUT                                           5 DAY WEATHER FORECASTING STATION
                    Operating Condition                           BATTERY 1.5V*2
                    Test Condition                                Ambient Temperature: 25°C Humidity: 56%
                    Test Date:                                    16 November 2012
                    Operator                                      Duke
                    MODEL NO                                      341NC

               Below 1GHz




                    No.        Frequency                 Factor               Reading               Level                   Limit                  Margin             Det.
                                 (MHz)                   (dB/m)              (dBµV/m)             (dBµV/m)                (dBµV/m)                  (dB)
                      1         32.1643                  -35.08                50.33                15.25                   40.00                  -24.75             QP
                      2         77.0741                  -38.29                49.51                11.22                   40.00                  -28.78             QP
                      3         119.2786                 -36.32                50.34                14.02                   43.50                  -29.48             QP
                      4         143.0862                 -35.04                48.94                13.90                   43.50                  -29.60             QP
                      5         190.7014                 -31.30                48.32                17.02                   43.50                  -26.48             QP
                      6         295.1303                 -26.12                47.51                21.39                   46.00                  -24.61             QP




opyright of this report is owned by Centre of Testing Service and may not be reproduced other than in full except with the written approval of the issuing Company.


CENTRE OF TESTING SERVICE CO., LTD.
Building F, Dachuang industrial park, No.379, Zhongshan Dadao, Guangzhou, China
Tel:+86-20-85543113 (32 lines)                 Fax:+86-20-38780406
Complaint line:+86-20-85533471                 E-mail:cts@cts-lab.com.cn                         See Reverse For Terms And Conditions of Service


Report No.: CGZ3121113-00911-EFI                                                                                                                                 Page 13 of 17


    FCC ID:A6N-341RX




                   No.         Frequency                 Factor               Reading               Level                   Limit                  Margin             Det.
                                 (MHz)                   (dB/m)              (dBµV/m)             (dBµV/m)                (dBµV/m)                  (dB)
                     1          343.4870                 -33.40                47.52                14.12                   46.00                  -31.88             QP
                     2          487.9760                 -30.30                47.61                17.31                   46.00                  -28.69             QP
                     3          626.8537                 -27.88                46.57                18.69                   46.00                  -27.31             QP
                     4          751.7034                 -27.07                46.63                19.56                   46.00                  -26.44             QP
                     5          904.6092                 -25.27                46.30                21.03                   46.00                  -24.97             QP
                     6          988.7776                 -29.63                46.30                16.67                   54.00                  -37.33             QP


               Above 1GHz

                   No.         Frequency                 Factor               Reading               Level                   Limit                  Margin             Det.
                                 (MHz)                   (dB/m)              (dBµV/m)             (dBµV/m)                (dBµV/m)                  (dB)
                    1           1815.631                 -25.36                47.25                21.89                   74.00                  -52.11             peak
                    2           1815.631                 -25.36                34.68                 9.32                   54.00                  -44.68             AVG
                    3           4284.569                  -6.71                46.20                39.49                   74.00                  -34.51             peak
                    4           4284.569                  -6.71                33.85                27.14                   54.00                  -26.86             AVG
                    5           4505.010                  -7.25                47.26                40.01                   74.00                  -33.99             peak
                    6           4505.010                  -7.25                35.71                28.46                   54.00                  -25.54             AVG
                    7           6246.493                 -13.22                46.49                33.27                   74.00                  -40.73             peak
                    8           6246.493                 -13.22                33.67                20.45                   54.00                  -33.55             AVG
                    9           7855.711                 -15.05                46.11                31.06                   74.00                  -42.94             peak
                    10          7855.711                 -15.05                35.42                20.37                   54.00                  -33.63             AVG
                    11          9927.856                 -15.74                46.92                31.18                   74.00                  -42.82             peak
                    12          4813.627                  -9.55                37.68                28.13                   54.00                  -25.87             AVG




opyright of this report is owned by Centre of Testing Service and may not be reproduced other than in full except with the written approval of the issuing Company.


CENTRE OF TESTING SERVICE CO., LTD.
Building F, Dachuang industrial park, No.379, Zhongshan Dadao, Guangzhou, China
Tel:+86-20-85543113 (32 lines)                 Fax:+86-20-38780406
Complaint line:+86-20-85533471                 E-mail:cts@cts-lab.com.cn                         See Reverse For Terms And Conditions of Service


Report No.: CGZ3121113-00911-EFI                                                                                                                                 Page 14 of 17


    FCC ID:A6N-341RX




                    Channel:                                  433.92 MHz                                                  Result:          ■ - passed
                    Test point:                               Vertical                                                                     □ - not passed
                    Frequency range:                          30MHz-18GHz

                    EUT                                           5 DAY WEATHER FORECASTING STATION
                    Operating Condition                           BATTERY 1.5V*2
                    Test Condition                                Ambient Temperature: 25°C Humidity: 56%
                    Test Date:                                    16 November 2012
                    Operator                                      Duke
                    MODEL NO                                      341NC

               Below 1GHz




                    No.        Frequency                 Factor               Reading               Level                   Limit                  Margin             Det.
                                 (MHz)                   (dB/m)              (dBµV/m)             (dBµV/m)                (dBµV/m)                  (dB)
                      1         38.6573                  -40.50                58.48                17.98                   40.00                  -22.02             QP
                      2         75.4509                  -38.28                50.79                12.51                   40.00                  -27.49             QP
                      3         136.0521                 -34.90                48.91                14.01                   43.50                  -29.49             QP
                      4         186.3727                 -32.46                49.54                17.08                   43.50                  -26.42             QP
                      5         212.8858                 -31.42                48.53                17.11                   43.50                  -26.39             QP
                      6         294.5892                 -26.19                48.49                22.30                   46.00                  -23.70             QP




opyright of this report is owned by Centre of Testing Service and may not be reproduced other than in full except with the written approval of the issuing Company.


CENTRE OF TESTING SERVICE CO., LTD.
Building F, Dachuang industrial park, No.379, Zhongshan Dadao, Guangzhou, China
Tel:+86-20-85543113 (32 lines)                 Fax:+86-20-38780406
Complaint line:+86-20-85533471                 E-mail:cts@cts-lab.com.cn                         See Reverse For Terms And Conditions of Service


Report No.: CGZ3121113-00911-EFI                                                                                                                                 Page 15 of 17


    FCC ID:A6N-341RX




                    No.        Frequency                 Factor               Reading               Level                   Limit                  Margin             Det.
                                 (MHz)                   (dB/m)              (dBµV/m)             (dBµV/m)                (dBµV/m)                  (dB)
                      1         337.8758                 -33.80                46.86                13.06                   46.00                  -32.94             QP
                      2         486.5731                 -30.26                46.39                16.13                   46.00                  -29.87             QP
                      3         625.4509                 -27.81                45.51                17.70                   46.00                  -28.30             QP
                      4         761.5230                 -26.40                44.84                18.44                   46.00                  -27.56             QP
                      5         889.1784                 -25.57                45.62                20.05                   46.00                  -25.95             QP
                      6         988.7776                 -29.63                46.63                17.00                   54.00                  -37.00             QP



                  Above 1GHz

                    No.        Frequency                 Factor               Reading               Level                   Limit                  Margin             Det.
                                 (MHz)                   (dB/m)              (dBµV/m)             (dBµV/m)                (dBµV/m)                  (dB)
                      1         1617.234                 -26.03                47.57                21.54                   74.00                  -52.46             peak
                      2         1617.234                 -26.03                35.81                 9.78                   54.00                  -44.22             AVG
                      3         2102.204                 -26.66                47.46                20.80                   74.00                  -53.20             peak
                      4         2102.204                 -26.66                36.34                 9.68                   54.00                  -44.32             AVG
                      5         7679.359                  -5.78                27.07                21.29                   74.00                  -52.71             peak
                      6         7679.359                  -5.78                14.92                 9.14                   54.00                  -44.86             AVG
                      7         9288.577                  -8.21                36.61                28.40                   74.00                  -45.60             peak
                      8         9288.577                  -8.21                20.55                12.34                   54.00                  -41.66             AVG
                      9        10611.222                  -5.15                38.18                33.03                   74.00                  -40.97             peak
                     10        10611.222                  -5.15                26.02                20.87                   54.00                  -33.13             AVG
                     11        11603.206                  -4.58                38.84                34.26                   74.00                  -39.74             peak
                     12        11603.206                  -4.58                26.59                22.01                   54.00                  -23.56             AVG

                     Note:Level=Reading+Facytor.                             Margin= Level- Limit.
                  Remark: Others frequency Radiated Emission level margin all >10dB of Limit.
opyright of this report is owned by Centre of Testing Service and may not be reproduced other than in full except with the written approval of the issuing Company.


CENTRE OF TESTING SERVICE CO., LTD.
Building F, Dachuang industrial park, No.379, Zhongshan Dadao, Guangzhou, China
Tel:+86-20-85543113 (32 lines)                 Fax:+86-20-38780406
Complaint line:+86-20-85533471                 E-mail:cts@cts-lab.com.cn                         See Reverse For Terms And Conditions of Service


Report No.: CGZ3121113-00911-EFI                                                                                                                                 Page 16 of 17


    FCC ID:A6N-341RX




         8. Manufacturer/ Approval holder Declaration

                          The following identical model(s):


                                                                                               341NU,341BC, 341BU

                          Belong to the tested device:


                          Product description: 5 DAY WEATHER FORECASTING STATION
                          Model name: 341NC




opyright of this report is owned by Centre of Testing Service and may not be reproduced other than in full except with the written approval of the issuing Company.


CENTRE OF TESTING SERVICE CO., LTD.
Building F, Dachuang industrial park, No.379, Zhongshan Dadao, Guangzhou, China
Tel:+86-20-85543113 (32 lines)                 Fax:+86-20-38780406
Complaint line:+86-20-85533471                 E-mail:cts@cts-lab.com.cn                         See Reverse For Terms And Conditions of Service


Report No.: CGZ3121113-00911-EFI                                                                                                                                 Page 17 of 17



Document Created: 2012-12-10 09:43:19
Document Modified: 2012-12-10 09:43:19

© 2024 FCC.report