18_WPC10-2TX01 RFExp

FCC ID: A4XWPC10-2TX01

RF Exposure Info

Download: PDF
FCCID_4141492

                                                                                  Model: WPCIO—2TXOL




                 Measurement and Test Report
                                              For

                                   CE LINK LIMITED

            Building G, Li Cheng Technology Industrial Zone, Gong He

                    Village, Sha Jing Town, Shen Zhen City, China



                            FCC ID: A4XWPC10—2TXOL


 FCC Rule(s):                        KDB 680106 DQ1 ¥O3

 Product Description:                Wireless Charger

 Tested Model:                       WwPC10—2TX01

 Report No.:                         WTX19X01001989W—2

 Tested Date:                        2019—01—09

 Issued Date:                        2019—01—10 to 2019—01—18

 Tested By:                          2019—01—18
                                                                         hm
                                                                      JMM Ar
                                                                              4
                                                                     Ma—Chemn
 Reviewed By:                        Silin Chen / EMG Manager        s             *

 Approved & Authorized By:           Jandy So / PSQ Manager          J"”(fiw

 Prepared By:
                        Shenzhen SEM Test Technology Co., Ltd.
                     1/F, Building A, Hongwei Industrial Park, Liuxian 2nd Road,
                      Bac‘an District, Shenzhen, P.R.C. (518101)
          Tel.: +86—755—33663908   Fax.: +86—755—33063909 Website: www.semtest.com.cn



   Note: This test report is limited to the above client company and the product model only. It
   may not be duplicated without prior permitted by Shenzhen SEM Test Technology Co., Ltd.


REPORT NO.: WTXI9X01001939W—2                  PAGE 1 OF 7                                REExposure


                                                                                                                                            Model: WPC10-2TX01


TABLE OF CONTENTS
1. GENERAL INFORMATION ...................................................................................................................................3
   1.1 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) ...............................................................................3
2. RF EXPOSURE TEST REPORT ............................................................................................................................4
   2.1 STANDARD APPLICABLE.........................................................................................................................................4
   2.2 TEST CONDITIONS ..................................................................................................................................................4
   2.3 TEST PROCEDURE ...................................................................................................................................................5
   2.4 TEST RESULT..........................................................................................................................................................5
   2.4 TEST PHOTOS .........................................................................................................................................................7




REPORT NO.: WTX19X01001939W-2                                                        PAGE 2 OF 7                                                             RFExposure


                                                                                            Model: WPC10-2TX01


1. GENERAL INFORMATION

1.1 Product Description for Equipment Under Test (EUT)

  Client Information
  Applicant:                                    CE LINK LIMITED
  Address of applicant:                         Building G, Li Cheng Technology Industrial Zone,
                                                Gong He Village, Sha Jing Town, Shen Zhen City,
                                                China

  Manufacturer:                                 CE LINK LIMITED
  Address of manufacturer:                      Building G, Li Cheng Technology Industrial Zone,
                                                Gong He Village, Sha Jing Town, Shen Zhen City,
                                                China

  General Description of EUT
  Product Name:                                 Wireless Charger
  Trade Name:                                   CE-LINK
  Model No.:                                    WPC10-2TX01
  Adding Model(s):                              /

  Note: The test data is gathered from a production sample, provided by the manufacturer.


  Technical Characteristics of EUT
  Wireless Charger Transmit
                                                110~205KHz
  Frequency Range:
  Antenna Type:                                 Coil Antenna
  Voltage:                                      Input 5V/9V
  Current:                                      2A/1.8A
  Output Power:                                 5W/7.5W/10W




REPORT NO.: WTX19X01001939W-2                        PAGE 3 OF 7                                    RFExposure


                                                                                          Modet who to—zrxou


2. RF Exposure Test Report

2.1 Standard Applicable
According to 5 1.1310 system operating under the provisions ofthis section shall be operating in a manner that
the public is not exposed to radio frequency energy level i excess limit for maximum permissible exposure.

                               Trece 1—Lis ron Mecuou Penussoce Exrosne (UPE)

 Erequency range     [Electrc fieldstrength   Magnetic ield strength     [Po¥er density     Inveraging time
 [ute)               (Vm)                       (Alm)                     (mwicm?)       (minutes)
                               (8) Limits for OccupationallControlled xposure
 b330                                        sn                       18            "d                         &
 ozo                                      Tar                        aoor          sove                        s
 Fozwo                                      ara                      mss              10                       &
 Foo—1 soo                                                                          van                        s
 [1s00—100.000                                                                         s                       s
                                   is for General Population/Uncontroled Exposure
 b3iz                                        en                       18            "d                        zo
 tsez0                                     seur                      Zior          oe                         5o
 Fozwo                                      2s                       sors             o2                      zo
 Foo—1 soo                                                                         ¥1s00                      zo
 [1s00—100.000                                                                        10                      El
    1=fequency in MFtz = Plane—wave equialent power densty

2.2 Test Con

     Test Mode                Description                  Remark                 Power Supply Mode
        Tw                      Works               Comnect to wiseless joag     C SY (ith a adapter mpur
                                  orking             ‘omect to wircless loxd        ac roviony
                                     .                           .               DCV (with a adapter input
         o                      Working             Comnect to wireless load
                                                                                    ac rovisor)

   Measurement
       .                                                       I5em
     Distance:




Report No: wixtoxoroo maow2                          Faceaor?                                      Rhexpoure


                                                                                      Model: WPC10-2TX01



2.3 Test Procedure




a. The measurement probe was placed at test distance(15 cm for A,B,C,D,F and 20 cm for E) which is between
   the edge of the charger and the geometric center of probe.
b. The highest emission level was recorded at the measurement points(A, B, C, D, E, F).
c. The EUT was measured according to the distance of KDB 680106 D01 V03.

2.4 Test Result

The EUT dose comply with item 5.2 of KDB 680106 D01V03

1. Power transfer frequency is less that 1 MHz
     Yes, the device operate in the frequency range from 110kHz to 205kHz.


2. Output power from each primary coil is less than 15 watts
     Yes, the maximum output power of the primary coil is less than 15W.


3. The transfer system includes only single primary and secondary coils. This includes
     charging systems that may have multiple primary coils and clients that are able
     to detect and allow coupling only between individual pairs of coils
     Yes, the client device includes only single primary coils.


4. Client device is inserted in or placed directly in contact with the transmitter
     Yes, Client device is placed directly in contact with the transmitter.


5. Mobile exposure conditions only (portable exposure conditions are not covered by
     this exclusion).
     Yes, It is mobile exposure conditions only.


REPORT NO.: WTX19X01001939W-2                       PAGE 5 OF 7                                 RFExposure


                                                                               Model: WPC10-2TX01



6. The aggregate H-field strengths at 15 cm surrounding the device and 20 cm above
   the top surface from all simultaneous transmitting coils are demonstrated to be
   less than 50% of the MPE limit.
   Yes, The EUT field strength levels are less than 50% of the MPE limit, refer to
   test TM1, TM2 list, and the coils can’t transmitted simultaneous.


Test Mode: TM1 (with mobile phone)
                                       Electric Field Emissions
      Test Position             Measure Value (V/m)               Limit(V/m)    50% Limit (V/m)
          Top                          3.62                          614              307
        Bottom                         4.02                          614              307
         Side 1                        5.11                          614              307
         Side 2                        3.72                          614              307
         Side 3                        4.05                          614              307
         Side 4                        3.77                          614              307


                                      Magnetic Field Emissions
      Test Position             Measure Value (A/m)               Limit(A/m)    50% Limit (A/m)
          Top                         0.0165                         1.63            0.815
        Bottom                        0.0178                         1.63            0.815
         Side 1                       0.0161                         1.63            0.815
         Side 2                       0.0180                         1.63            0.815
         Side 3                       0.0175                         1.63            0.815
         Side 4                       0.0173                         1.63            0.815




REPORT NO.: WTX19X01001939W-2                    PAGE 6 OF 7                           RFExposure


                                                                               Model: WPC10-2TX01



Test Mode: TM2(with mobile phone)
                                       Electric Field Emissions
     Test Position              Measure Value (V/m)               Limit(V/m)    50% Limit (V/m)
          Top                          3.52                          614              307
        Bottom                         3.98                          614              307
         Side 1                        3.74                          614              307
         Side 2                        4.05                          614              307
         Side 3                        3.64                          614              307
         Side 4                        4.23                          614              307


                                      Magnetic Field Emissions
     Test Position              Measure Value (A/m)               Limit(A/m)    50% Limit (A/m)
          Top                         0.0171                         1.63            0.815
        Bottom                        0.0181                         1.63            0.815
         Side 1                       0.0168                         1.63            0.815
         Side 2                       0.0187                         1.63            0.815
         Side 3                       0.0175                         1.63            0.815
         Side 4                       0.0172                         1.63            0.815

2.4 Test Photos




                                    ***** END OF REPORT *****




REPORT NO.: WTX19X01001939W-2                    PAGE 7 OF 7                           RFExposure