14_WPC10-2TX01 TestRpt

FCC ID: A4XWPC10-2TX01

Test Report

Download: PDF
FCCID_4141489

I7]
                                                                                     Model: WPCIO—2TXO1




                                     FCC Part 18
                  Measurement and Test Report
                                                For

                                     CE LINK LIMITED

             Building G, Li Cheng Technology Industrial Zone, Gong He

                      Village, Sha Jing Town, Shen Zhen City, China



                               FCC ID: A4XWPC10—2TXO1


  Test Rule(s):                        ECC Part 18

  Product Description:                 Wireless Charger

  Tested Model:                        wPG10—2TX01

  Report No.:                          WTX1 9X01001 939W—1

  Sample Receipt Date:                 2019—01—09

  Tested Date:                         2019—01—10 to 2019—01—18

  Issued Date:                         2019—01—18


  Tested By:
                                                       :
                                       Jason Su / Engineer
                                                                                4
                                                                                A

                                                                                 Chan
  Reviewed By:                         Silin Chen / EMGC Manager          *      "    9

  Approved & Authorized By:            Jandy So / PSQ Manager             J”’(ZW

  Prepared By:
                          Shenzhen SEM Test Technology Co., Ltd.
                        1/F, Building A, Hongwei Industrial Park, Liuxian 2nd Road,
                         Bac‘an District, Shenzhen, P.R.C. (518101)
            Tel.: +86—755—33663808   Fax.: +86—755—33608309      Website: www.semfest.com.cn


    Note: This test report is limited to the above client company and the product model only. It
    may not be duplicated without prior permitted by Shenzhen SEM Test Technology Co., Lid.


Report No.: WTX 19X0100 1939W—I1                  Page I of 21                              FCC Part 18


                                                                                                                                            Model: WPC10-2TX01


TABLE OF CONTENTS
1. GENERAL INFORMATION ...................................................................................................................................3
   1.1 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) ...............................................................................3
   1.2 TEST STANDARDS...................................................................................................................................................4
   1.3 TEST METHODOLOGY .............................................................................................................................................4
   1.4 TEST FACILITY .......................................................................................................................................................4
   1.5 EUT SETUP AND OPERATION MODE ......................................................................................................................5
   1.6 MEASUREMENT UNCERTAINTY ..............................................................................................................................5
   1.7 TEST EQUIPMENT LIST AND DETAILS .....................................................................................................................6
2. SUMMARY OF TEST RESULTS ...........................................................................................................................7
3. CONDUCTED EMISSIONS ....................................................................................................................................8
   3.1 STANDARD APPLICABLE.........................................................................................................................................8
   3.2 TEST PROCEDURE ...................................................................................................................................................8
   3.3 BASIC TEST SETUP BLOCK DIAGRAM.....................................................................................................................8
   3.4 ENVIRONMENTAL CONDITIONS ..............................................................................................................................9
   3.5 TEST RECEIVER SETUP ...........................................................................................................................................9
   3.6 SUMMARY OF TEST RESULTS/PLOTS ......................................................................................................................9
4. RADIATED EMISSIONS .......................................................................................................................................14
   4.1 TEST PROCEDURE .................................................................................................................................................14
   4.2 TEST RECEIVER SETUP .........................................................................................................................................14
   4.3 CORRECTED AMPLITUDE & MARGIN CALCULATION ............................................................................................14
   4.4 ENVIRONMENTAL CONDITIONS ............................................................................................................................15
   4.5 SUMMARY OF TEST RESULTS/PLOTS ....................................................................................................................15




Report No.: WTX19X01001939W-1                                                         Page 2 of 21                                                        FCC Part 18


                                                                                            Model: WPC10-2TX01


1. GENERAL INFORMATION

1.1 Product Description for Equipment Under Test (EUT)

  Client Information
  Applicant:                                    CE LINK LIMITED
  Address of applicant:                         Building G, Li Cheng Technology Industrial Zone,
                                                Gong He Village, Sha Jing Town, Shen Zhen City,
                                                China

  Manufacturer:                                 CE LINK LIMITED
  Address of manufacturer:                      Building G, Li Cheng Technology Industrial Zone,
                                                Gong He Village, Sha Jing Town, Shen Zhen City,
                                                China

  General Description of EUT
  Product Name:                                 Wireless Charger
  Trade Name:                                   CE-LINK
  Model No.:                                    WPC10-2TX01
  Adding Model(s):                              /

  Note: The test data is gathered from a production sample, provided by the manufacturer.


  Technical Characteristics of EUT
  Voltage:                                      Input 5V/9V
  Current:                                      2A/1.8A
  Output Power:                                 5W/7.5W/10W
  Power Adapter Model:                          /
  Wireless Charger Transmit
                                                110~205KHz
  Frequency Range:




Report No.: WTX19X01001939W-1                         Page 3 of 21                                 FCC Part 18


                                                                                            Model: WPC10-2TX01



1.2 Test Standards

The tests were performed according to following standards:
FCC Part 18 Subpart C: Industrial, Scientific, and medical equipment.

ANSI C63.4-2014:American National Standard for Methods of Measurement of Radio-Noise Emissions from
Low-Voltage Electrical and Electronic Equipment in the range of 9 kHz to 40 GHz.

Maintenance of compliance is the responsibility of the manufacturer. Any modification of the product, which
result in lowering the emission, should be checked to ensure compliance has been maintained.

1.3 Test Methodology

All measurements contained in this report were conducted with ANSI C63.4-2014, American National Standard
for Methods of Measurement of Radio-Noise Emissions from Low-Voltage Electrical and Electronic Equipment in
the range of 9 kHz to 40 GHz.

1.4 Test Facility
The test facility is recognized, certified, or accredited by the following organizations:


FCC – Registration No.: 125990
Shenzhen SEM Test Technology Co., Ltd. Laboratory has been recognized to perform compliance testing on
equipment subject to the Commissions Declaration Of Conformity (DOC). The Designation Number is CN5010,
and Test Firm Registration Number is 125990.


Industry Canada (IC) Registration No.: 11464A
The 3m Semi-anechoic chamber of Shenzhen SEM Test Technology Co., Ltd. has been registered by Certification
and Engineering Bureau of Industry Canada for radio equipment testing with Registration No.: 11464A.




Report No.: WTX19X01001939W-1                             Page 4 of 21                             FCC Part 18


                                                                                 Meas: weero.zrxo!

1.5 EUT Setup and Operation Mode
"The equimnentundertest (EUT) was configuredto measie is highest pssble erissio fevel.The testmodes
wer adapted secording tothe operation manual foruse, more dexiled desription as ollows
    TestMode Lise
      Tes: Mode            Deseription                Remurk              Pover Supply Mode
        Tan              Wirtess Ouiput                  1                  Inpu. DCsvaA;
                                                                            Oupmbcsvia
                                                                           Input DCVLaA;
        mz               Wirkess Ouiput                  1                 Cupepcoviia

    EUT Cible Lis and Dewils
        Cible Desripion            Length 0)       ShieedUnstielded With ConWihout Core
          TypeCCaole                   12               stieled         Witout Forie

    Auailiny Enuipment Listand Detils
           Deseriion            Manufictirer             Moet                 SernlNumber
                                                   sgoea—t201500—20
             Adapter                     uce               1                        1
          iProve5 Plus                   Apcle        mosezcrn                      7
    Specil Cable it and Devils
        Cible Desripion        Length 0)           ShieedUnstielded With ConWihout Core
                  7                        7                 7                     7

1.6 Measurement Uncertainty
 Measurement unceriainty
               Porsmeter                               Cooditions                   Uncersiny
                                                                                s—150i0te 43709
           Conducted Emisions                          Conducted               meemmeprenn
                                                                               30—2000iHe +45z08
                                                                                02—ighe +3 sean
              Radinted Enisions                          Radined
                                                                                 Logk433009
                                                                                élaite +19008




Reyon No: wixrexoron mm 1                         Tag sere                               Tecrans


                                                                               Model: WPC10-2TX01



1.7 Test Equipment List and Details

         Description       Manufacturer      Model         Serial No.   Cal Date   Due Date
      Spectrum Analyzer      Agilent         E4407B      MY41440400     2018-05-22 2019-05-21
      Spectrum Analyzer   Rohde & Schwarz     FSP30       836079/035    2018-05-22 2019-05-21
      EMI Test Receiver   Rohde & Schwarz     ESVB        825471/005    2018-05-22 2019-05-21
          Amplifier             Agilent       8447F       3113A06717    2018-05-22 2019-05-21
          Amplifier             C&D         PAP-1G18           2002     2018-05-22 2019-05-21
      Broadband Antenna    Schwarz beck     VULB9163       9163-333     2017-06-08 2018-06-07
        Horn Antenna             ETS          3117         00086197     2017-06-08 2018-06-07
        Loop Antenna       Schwarz beck     FMZB 1516          9773     2017-06-08 2018-06-07
      EMI Test Receiver   Rohde & Schwarz     ESPI             101611   2018-05-22 2019-05-21
           L.I.S.N         Schwarz beck     NSLK8126       8126-224     2018-05-22 2019-05-21
        Pulse Limiter     Rohde & Schwarz    ESH3-Z2           100911   2018-05-22 2019-05-21




Report No.: WTX19X01001939W-1                   Page 6 of 21                          FCC Part 18


                                                       Meas: weero.zrxo!

2. SUMMARY OF TEST RESULTS


        reeruues            besciurnion or Test    xesutr
         Es sor m             Conducted Enission   Compliont
         essm                  Raciied Ertision    Compliont




Reyon No: wixrexoron mm 1              Tag rore                Tecrans


                                                                                         Model: WPC10-2TX01


3. Conducted Emissions

3.1 Standard Applicable

According to FCC 18.307(b), the radio frequency voltage that is conducted back onto the AC power line on any
frequency or frequencies shall not exceed the limits in the following tables:


                                                        Conducted limit (dBμV)
              Frequency (MHz)
                                               Quasi-peak                     Average
                   0.15-0.5                      66 to 56                     56 to 46
                    0.5-5                          56                            46
                     5-30                          60                            50

3.2 Test Procedure

The setup of EUT is according with per ANSI C63.4-2014 measurement procedure. The specification used was
with the FCC Part 18.307 Limit.
The external I/O cables were draped along the test table and formed a bundle 30 to 40 cm long in the middle.
The spacing between the peripherals was 10 cm.

3.3 Basic Test Setup Block Diagram




Report No.: WTX19X01001939W-1                        Page 8 of 21                               FCC Part 18


                                                                                                     Model: WPC10-2TX01



3.4 Environmental Conditions

   Temperature:                   23.5 C
   Relative Humidity:             55
   ATM Pressure:                  1016 mbar


3.5 Test Receiver Setup
During the conducted emission test, the test receiver was set with the following configurations:

                        Start Frequency .................................................. 150 kHz
                        Stop Frequency................................................... 30 MHz
                        Sweep Speed ...................................................... Auto
                        IF Bandwidth ...................................................... 10 kHz
                        Quasi-Peak Adapter Bandwidth ......................... 9 kHz
                        Quasi-Peak Adapter Mode ................................. Normal

3.6 Summary of Test Results/Plots

According to the data in this section, the EUT complied with the FCC Part 18C Conducted margin for Any
non-ISM frequency device, with the worst margin reading of:

                   -3.50 dB at 0.2100 MHz in the Line, QP detector, TM2 detector, 0.15-30MHz




Report No.: WTX19X01001939W-1                                         Page 9 of 21                          FCC Part 18


                                                                                    Model: WPC10-2TX01



         Test mode:                  TM1                           Polarity:                Line




   No.         Frequency   Reading         Correct        Result           Limit   Margin          Detector
                 (MHz)     (dBuV)          (dB/m)        (dBuV)           (dBuV)    (dB)
   1*           0.1499      40.52          10.10          50.62            66.00   -15.38            QP
    2           0.2100      23.06          10.13          33.19            53.20   -20.01           AVG
    3           0.3580      32.32          10.23          42.55            58.77   -16.22            QP
    4           0.3580      20.48          10.23          30.71            48.77   -18.06           AVG
    5           5.1899      22.57          10.77          33.34            60.00   -26.66            QP
    6           5.1939      8.04           10.77          18.81            50.00   -31.19           AVG




Report No.: WTX19X01001939W-1                        Page 10 of 21                           FCC Part 18


                                                                                    Model: WPC10-2TX01



         Test mode:                  TM1                           Polarity:                Neutral




   No.         Frequency   Reading         Correct        Result           Limit   Margin         Detector
                 (MHz)     (dBuV)          (dB/m)        (dBuV)           (dBuV)    (dB)
    1           0.1500      41.93          10.10          52.03            66.00   -13.97             QP
    2           0.2060      24.08          10.12          34.20            53.37   -19.17             AVG
   3*           0.2900      37.74          10.18          47.92            60.52   -12.60             QP
    4           0.2900      21.85          10.18          32.03            50.52   -18.49             AVG
    5           5.1900      25.23          10.77          36.00            60.00   -24.00             QP
    6           5.1900      10.55          10.77          21.32            50.00   -28.68             AVG




Report No.: WTX19X01001939W-1                        Page 11 of 21                             FCC Part 18


                                                                                    Model: WPC10-2TX01



         Test mode:                  TM2                           Polarity:                Line




   No.         Frequency   Reading         Correct        Result           Limit   Margin          Detector
                 (MHz)     (dBuV)          (dB/m)        (dBuV)           (dBuV)    (dB)
   1*           0.2100      49.58          10.13          59.71            63.21   -3.50             QP
    2           0.2100      35.15          10.13          45.28            53.21   -7.93            AVG
    3           0.2780      44.40          10.17          54.57            60.88   -6.31             QP
    4           0.2780      27.19          10.17          37.36            50.88   -13.52           AVG
    5           0.3460      42.06          10.21          52.27            59.06   -6.79             QP
    6           0.3460      24.90          10.21          35.11            49.06   -13.95           AVG




Report No.: WTX19X01001939W-1                        Page 12 of 21                           FCC Part 18


                                                                                    Model: WPC10-2TX01



         Test mode:                  TM2                           Polarity:                Neutral




   No.         Frequency   Reading         Correct        Result           Limit   Margin         Detector
                 (MHz)     (dBuV)          (dB/m)        (dBuV)           (dBuV)    (dB)
   1*           0.2060      44.03          10.12          54.15            63.37   -9.22              QP
    2           0.2100      27.54          10.13          37.67            53.21   -15.54             AVG
    3           0.2900      39.78          10.18          49.96            60.52   -10.56             QP
    4           0.2900      25.37          10.18          35.55            50.52   -14.97             AVG
    5           24.3380     13.21          11.22          24.43            50.00   -25.57             AVG
    6           26.8260     26.95          11.23          38.18            60.00   -21.82             QP




Report No.: WTX19X01001939W-1                        Page 13 of 21                             FCC Part 18


                                                                                          Model: WPC10-2TX01


4. Radiated Emissions

4.1 Test Procedure

The setup of EUT is according with per ANSI C63.4-2014 measurement procedure. The specification used was
with the FCC Part 18.305 Limit.
The external I/O cables were draped along the test table and formed a bundle 30 to 40 cm long in the middle.
The spacing between the peripherals was 10 cm.


                                                              Antenna
                                                               Tower




                                                                            1m-4m
                                         3m

                  EUT
                                  0.8m




               Turntable
                Table                                                                    To EMI Receiver



                                              Ground Plane


4.2 Test Receiver Setup

Frequency :9kHz-30MHz                    Frequency :30MHz-1GHz                  Frequency :Above 1GHz
RBW=10KHz,                               RBW=120KHz,                            RBW=1MHz,
VBW =30KHz                               VBW=300KHz                             VBW=3MHz(Peak), 10Hz(AV)
Sweep time= Auto                         Sweep time= Auto                       Sweep time= Auto
Trace = max hold                         Trace = max hold                        Trace = max hold
Detector function = peak                 Detector function = peak, QP            Detector function = peak, AV

4.3 Corrected Amplitude & Margin Calculation

The Corrected Amplitude is calculated by adding the Antenna Factor and the Cable Factor, and subtracting the
Amplifier Gain from the Amplitude reading. The basic equation is as follows:

                                     Corr. Ampl. = Indicated Reading – Corr. Factor

The “Margin” column of the following data tables indicates the degree of compliance with the applicable limit.
For example, a margin of -6dBV means the emission is 6dBV below the maximum limit for Any non-ISM
frequency device. The equation for margin calculation is as follows:

Report No.: WTX19X01001939W-1                           Page 14 of 21                              FCC Part 18


                                                                                        Model: WPC10-2TX01



                                   Margin = Corr. Ampl. – FCC Part 18.305 Limit

4.4 Environmental Conditions

   Temperature:            22 C
   Relative Humidity:      54 
   ATM Pressure:           1011 mbar

4.5 Summary of Test Results/Plots

According to the data, the EUT complied with the FCC Part 18.305 rule, and had the worst margin of:

           -6.44 dB at 0.0091 MHz in the Vertical polarization, TM2 mode, Below 30MHz, 3Meters




Report No.: WTX19X01001939W-1                           Page 15 of 21                             FCC Part 18


                                                                                            Model: WPC10-2TX01



     Plot of Radiated Emissions Test Data (Below 30MHz)


         Test mode:                   TM1                          Polarity:                     Vertical




No.     Frequency     Reading    Correct     Result        Limit        Margin    Degree        Height      Remark
          (MHz)       (dBuV/m)    dB/m      (dBuV/m)     (dBuV/m)         (dB)    (         )   (cm)
 1         0.0096      122.36     -26.28     96.08         103.50        -7.42        72         100         peak
 2         0.0677      94.05      -26.27     67.78         103.50        -35.72       157        100         peak
 3         0.1426      110.50     -26.25     84.25         103.50        -19.25       138        100         peak
 4         0.4282      88.20      -27.55     60.65         103.50        -42.85       150        100         peak
 5         0.7122      78.92      -29.19     49.73         103.50        -53.77       83         100         peak




Report No.: WTX19X01001939W-1                         Page 16 of 21                                    FCC Part 18


                                                                                           Model: WPC10-2TX01



      Test mode:                    TM2                           Polarity:                     Vertical




No.   Frequency    Reading      Correct    Result         Limit        Margin    Degree        Height      Remark
        (MHz)      (dBuV/m)     dB/m      (dBuV/m)     (dBuV/m)          (dB)    (         )   (cm)
 1      0.0091      123.34      -26.28     97.06         103.50         -6.44        202        100         peak
 2      0.0646      95.33       -26.27     69.06         103.50         -34.44       123        100         peak
 3      0.1394      110.46      -26.25     84.21         103.50         -19.29       67         100         peak
 4      0.4171      88.49       -27.49     61.00         103.50         -42.50       267        100         peak
 5      0.6936      80.03       -29.08     50.95         103.50         -52.55       126        100         peak
 6      0.9735      75.69       -30.70     44.99         103.50         -58.51       335        100         peak




Report No.: WTX19X01001939W-1                       Page 17 of 21                                     FCC Part 18


                                                                                            Model: WPC10-2TX01



     Plot of Radiated Emissions Test Data (Above 30MHz)


         Test mode:                  TM1                           Polarity:                    Horizontal




No.      Frequency    Reading    Correct    Result         Limit        Margin    Degree        Height     Remark
          (MHz)       (dBuV/m)    dB/m     (dBuV/m)     (dBuV/m)          (dB)    (         )   (cm)
 1        43.0505      34.87      -8.01      26.86         63.50         -36.64       52         100         QP
 2        65.1145      34.18     -12.21      21.97         63.50         -41.53       134        100         QP
 3       124.5690      35.58     -16.95      18.63         63.50         -44.87       114        100         QP
 4       255.6231      35.58     -11.08      24.50         63.50         -39.00       144        100         QP
 5       407.5145      32.47      -7.23      25.24         63.50         -38.26       249        100         QP
 6       656.5300      31.40      -3.31      28.09         63.50         -35.41       332        100         QP




Report No.: WTX19X01001939W-1                        Page 18 of 21                                     FCC Part 18


                                                                                           Model: WPC10-2TX01



      Test mode:                    TM1                           Polarity:                     Vertical




No.   Frequency    Reading      Correct    Result         Limit        Margin    Degree        Height      Remark
        (MHz)      (dBuV/m)     dB/m      (dBuV/m)     (dBuV/m)          (dB)    (         )   (cm)
 1      47.8260     36.09        -8.16     27.93          63.50         -35.57       257        100         QP
 2      65.3432     37.34       -12.32     25.02          63.50         -38.48       170        100         QP
 3     153.7385     37.50       -17.23     20.27          63.50         -43.23       105        100         QP
 4     301.4224     32.72        -9.36     23.36          63.50         -40.14       146        100         QP
 5     625.0780     31.49        -3.76     27.73          63.50         -35.77       321        100         QP
 6     968.9338     31.58        3.25      34.83          63.50         -28.67       101        100         QP




Report No.: WTX19X01001939W-1                       Page 19 of 21                                     FCC Part 18


                                                                                           Model: WPC10-2TX01



      Test mode:                    TM2                           Polarity:                    Horizontal




No.   Frequency    Reading      Correct    Result         Limit        Margin    Degree        Height     Remark
        (MHz)      (dBuV/m)     dB/m      (dBuV/m)     (dBuV/m)          (dB)    (         )   (cm)
 1      39.4372     34.99        -8.61     26.38          63.50         -37.12       197        100         QP
 2      57.5939     35.58       -10.34     25.24          63.50         -38.26       236        100         QP
 3     106.3850     34.36       -14.49     19.87          63.50         -43.63       97         100         QP
 4     252.0627     35.93       -11.20     24.73          63.50         -38.77       262        100         QP
 5     280.0238     36.17       -10.08     26.09          63.50         -37.41       119        100         QP
 6     625.0780     31.88        -3.76     28.12          63.50         -35.38       291        100         QP




Report No.: WTX19X01001939W-1                       Page 20 of 21                                     FCC Part 18


                                                                                           Model: WPC10-2TX01



      Test mode:                    TM2                           Polarity:                     Vertical




No.   Frequency    Reading      Correct    Result         Limit        Margin    Degree        Height      Remark
        (MHz)      (dBuV/m)     dB/m      (dBuV/m)     (dBuV/m)          (dB)    (         )   (cm)
 1      33.0950     35.78        -9.77     26.01          63.50         -37.49       345        100         QP
 2      47.8260     34.88        -8.16     26.72          63.50         -36.78       95         100         QP
 3      65.5727     36.70       -12.42     24.28          63.50         -39.22       123        100         QP
 4      81.7833     38.06       -17.05     21.01          63.50         -42.49       102        100         QP
 5     114.1138     35.25       -15.15     20.10          63.50         -43.40       90         100         QP
 6     414.7223     32.30        -7.04     25.26          63.50         -38.24       219        100         QP




                                    ***** END OF REPORT *****




Report No.: WTX19X01001939W-1                       Page 21 of 21                                     FCC Part 18



Document Created: 2019-01-24 10:48:16
Document Modified: 2019-01-24 10:48:16

© 2025 FCC.report