RF Exposure Info._20190714_v1 - A4RG020MN_TestRpt_RFExp_Appendix B-3

FCC ID: A4RG020MN

RF Exposure Info

Download: PDF
FCCID_4414658

Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab   Date: 2019/5/2


#38_GSMS850_GPRS (4 Tx slots)_Back_10mm_Ch128



Communication System: GSM850 ; Frequency: 824.2 MHz;Duty Cycle: 1:2.08
Medium: HSL_850_190502 Medium parameters used : f = 824.2 MHz; 0 = 0.894 S/m; & = 43.108; p = 1000
kg/m3
Ambient Temperature : 23.3 °C ; Liquid Temperature : 22.3 °C

DASYS5 Configuration:
— Probe: ES3DV3 — SN3169; ConvF(6.39, 6.39, 6.39) @ 824.2 MHz; Calibrated: 2018/5/28
— Sensor—Surface: 3mm (Mechanical Surface Detection)
— Electronics: DAF4 Sn918; Calibrated: 2018/6/20
— Phantom: SAM_Left; Type: QDO0OP40CD; Serial: TP:1682
— Measurement SW: DASY52, Version 52.10 (2),SEMCAD X Version 14.6.12 (7450)


Area Scan (71x121x1):; Interpolated grid: dx=1.500 mm, dy=1.500 mm
Maximum value of SAR (interpolated) = 0.719 W/kg

Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value = 23.58 V/m; Power Drift =0.01 dB
Peak SAR (extrapolated) = 1.51 W/kg
SAR(I g) = 0.604 W/kg; SAR(10 g) = 0.336 W/kg
Maximum value of SAR (measured) = 0.744 W/kg

        dB
        0


        —3.20


        —6.40


        —9.60


        —12.80


        —16.00        C
                    0 dB = 0.744 W/kg = —1.28 dBW/kg


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab   Date: 2019/5/2

#39_GSM1900_GPRS (4 Tx slots)_Front_10mm_Ch661


Communication System: PCS; Frequency: 1880 MHz;Duty Cycle: 1:2.08
Medium: HSL_1900_190502 Medium parameters used: f = 1880 MHz; σ = 1.415 S/m; εr = 41.096;
ρ = 1000 kg/m3
                    23.6                      22.6

DASY5 Configuration:
- Probe: ES3DV3 - SN3169; ConvF(5.27, 5.27, 5.27) @ 1880 MHz; Calibrated: 2018/5/28
- Sensor-Surface: 3mm (Mechanical Surface Detection)
- Electronics: DAE4 Sn918; Calibrated: 2018/6/20
- Phantom: SAM_Left; Type: QD000P40CD; Serial: TP:1431
- Measurement SW: DASY52, Version 52.10 (2);SEMCAD X Version 14.6.12 (7450)


Area Scan (61x61x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm
Maximum value of SAR (interpolated) = 0.688 W/kg

Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value = 20.22 V/m; Power Drift = -0.02 dB
Peak SAR (extrapolated) = 0.903 W/kg
SAR(1 g) = 0.561 W/kg; SAR(10 g) = 0.344 W/kg
Maximum value of SAR (measured) = 0.647 W/kg




               0 dB = 0.647 W/kg = -1.89 dBW/kg


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab   Date: 2019/5/2

#40_WCDMA II_RMC 12.2Kbps_Front_10mm_Ch9538


Communication System: WCDMA; Frequency: 1907.6 MHz;Duty Cycle: 1:1
Medium: HSL_1900_190502 Medium parameters used: f = 1908 MHz; σ = 1.444 S/m; εr = 40.972;
ρ = 1000 kg/m3
                    23.6                    22.6

DASY5 Configuration:
- Probe: ES3DV3 - SN3169; ConvF(5.27, 5.27, 5.27) @ 1907.6 MHz; Calibrated: 2018/5/28
- Sensor-Surface: 3mm (Mechanical Surface Detection)
- Electronics: DAE4 Sn918; Calibrated: 2018/6/20
- Phantom: SAM_Left; Type: QD000P40CD; Serial: TP:1431
- Measurement SW: DASY52, Version 52.10 (2);SEMCAD X Version 14.6.12 (7450)


Area Scan (61x71x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm
Maximum value of SAR (interpolated) = 0.859 W/kg

Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value = 22.46 V/m; Power Drift = -0.01 dB
Peak SAR (extrapolated) = 1.11 W/kg
SAR(1 g) = 0.705 W/kg; SAR(10 g) = 0.434 W/kg
Maximum value of SAR (measured) = 0.827 W/kg




               0 dB = 0.827 W/kg = -0.82 dBW/kg


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab   Date: 2019/6/6

#41_WCDMA IV_RMC 12.2Kbps_Back_10mm_Ch1312


Communication System: WCDMA; Frequency: 1712.4 MHz;Duty Cycle: 1:1
Medium: HSL_1750_20190606 Medium parameters used: f = 1712.4 MHz; σ = 1.322 S/m; εr =
39.359; ρ = 1000 kg/m3
                      23.6                  22.6

DASY5 Configuration:
- Probe: ES3DV3 - SN3124; ConvF(5.18, 5.18, 5.18) @ 1712.4 MHz; Calibrated: 2019/1/15
- Sensor-Surface: 3mm (Mechanical Surface Detection)
- Electronics: DAE4 Sn316; Calibrated: 2019/1/3
- Phantom: SAM-Middle; Type: SAM; Serial: 1796
- Measurement SW: DASY52, Version 52.10 (2);SEMCAD X Version 14.6.12 (7450)


Area Scan (71x61x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm
Maximum value of SAR (interpolated) = 1.06 W/kg

Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value = 26.95 V/m; Power Drift = -0.09 dB
Peak SAR (extrapolated) = 1.48 W/kg
SAR(1 g) = 0.869 W/kg; SAR(10 g) = 0.467 W/kg
Maximum value of SAR (measured) = 1.07 W/kg




               0 dB = 1.07 W/kg = 0.29 dBW/kg


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab   Date: 2019/4/30


#42_WCDMA V_RMC 12.2Kbps_Back_10mm_Ch4132


Communication System: LTE; Frequency: 831.5 MHz;Duty Cycle: 1:1
Medium: HSL_850_190430 Medium parameters used: £ = 831.5 MHz; 0 = 0.874 S/m; & = 41.117; p = 1000
kg/m3
Ambient Temperature : 23.2 °C ; Liquid Temperature : 22.2 °C

DASYS5 Configuration:
— Probe: EX3DV4 — SN3931; ConvF(10.07, 10.07, 10.07) @ 831.5 MHz; Calibrated: 2018/9/27
— Sensor—Surface: 1.4mm (Mechanical Surface Detection)
— Electronics: DAFEA4 Sn1399; Calibrated: 2018/11/16
— Phantom: SAM_Left; Type: QDO0O0P40CD; Serial: TP:1682
— Measurement SW: DASY52, Version 52.10 (2),SEMCAD X Version 14.6.12 (7450)


Area Scan (61x121x1):; Interpolated grid: dx=1.500 mm, dy=1.500 mm
Maximum value of SAR (interpolated) = 0.890 W/kg

Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value = 34.80 V/m; Power Drift = —0.03 dB
Peak SAR (extrapolated) = 1.22 W/kg
SAR(I g) = 0.618 W/kg; SAR(10 g) = 0.333 W/kg
Maximum value of SAR (measured) = 0.932 W/kg

        dB
        0


        —2.96


        —5.91


        —8.8 7


        —11.82


        —14.78        C‘
                    0 dB =0.932 W/kg = —0.31 dBW/kg


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab   Date: 2019/5/5

#43_LTE Band 4_20M_QPSK_1_0_Back_10mm_Ch20175


Communication System: LTE; Frequency: 1732.5 MHz;Duty Cycle: 1:1
Medium: HSL_1750_190505 Medium parameters used: f = 1733 MHz; σ = 1.351 S/m; εr = 39.76; ρ
= 1000 kg/m3
                    23.1                      22.1

DASY5 Configuration:
- Probe: ES3DV3 - SN3169; ConvF(5.48, 5.48, 5.48) @ 1732.5 MHz; Calibrated: 2018/5/28
- Sensor-Surface: 3mm (Mechanical Surface Detection)
- Electronics: DAE3 Sn577; Calibrated: 2018/9/19
- Phantom: SAM_Left; Type: QD000P40CD; Serial: TP:1431
- Measurement SW: DASY52, Version 52.10 (2);SEMCAD X Version 14.6.12 (7450)


Area Scan (71x71x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm
Maximum value of SAR (interpolated) = 0.626 W/kg

Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value = 20.86 V/m; Power Drift = -0.06 dB
Peak SAR (extrapolated) = 0.805 W/kg
SAR(1 g) = 0.543 W/kg; SAR(10 g) = 0.355 W/kg
Maximum value of SAR (measured) = 0.623 W/kg




               0 dB = 0.623 W/kg = -2.06 dBW/kg


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab   Date: 2019/6/20

#44_LTE Band 7_20M_QPSK_50_0_Back_10mm_Ch20850


Communication System: LTE; Frequency: 2510 MHz;Duty Cycle: 1:1
Medium: HSL_2600_190620 Medium parameters used: f = 2510 MHz; σ = 1.87 S/m; εr = 38.421; ρ
= 1000 kg/m3
                    23.3                      22.3

DASY5 Configuration:
- Probe: ES3DV3 - SN3270; ConvF(4.43, 4.43, 4.43) @ 2510 MHz; Calibrated: 2018/9/24
- Sensor-Surface: 3mm (Mechanical Surface Detection)
- Electronics: DAE3 Sn577; Calibrated: 2018/9/19
- Phantom: SAM-Right; Type: SAM; Serial: TP-1503
- Measurement SW: DASY52, Version 52.10 (2);SEMCAD X Version 14.6.12 (7470)


Area Scan (91x81x1): Interpolated grid: dx=1.200 mm, dy=1.200 mm
Maximum value of SAR (interpolated) = 1.19 W/kg

Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm
Reference Value = 17.50 V/m; Power Drift = -0.11 dB
Peak SAR (extrapolated) = 1.90 W/kg
SAR(1 g) = 0.894 W/kg; SAR(10 g) = 0.397 W/kg
Maximum value of SAR (measured) = 1.19 W/kg




               0 dB = 1.19 W/kg = 0.76 dBW/kg


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab   Date: 2019/6/7

#45_LTE Band 12_20M_QPSK_1_25_Front_10mm_Ch23095


Communication System: LTE; Frequency: 707.5 MHz;Duty Cycle: 1:1
Medium: HSL_750_190607 Medium parameters used: f = 707.5 MHz; σ = 0.852 S/m; εr = 43.62; ρ
= 1000 kg/m3
                    23.4                      22.4

DASY5 Configuration:
- Probe: ES3DV3 - SN3124; ConvF(6.15, 6.15, 6.15) @ 707.5 MHz; Calibrated: 2019/1/15
- Sensor-Surface: 3mm (Mechanical Surface Detection)
- Electronics: DAE4 Sn316; Calibrated: 2019/1/3
- Phantom: SAM_Left; Type: QD000P40CD; Serial: TP:1431
- Measurement SW: DASY52, Version 52.10 (2);SEMCAD X Version 14.6.12 (7450)


Area Scan (61x71x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm
Maximum value of SAR (interpolated) = 0.369 W/kg

Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value = 14.19 V/m; Power Drift = -0.02 dB
Peak SAR (extrapolated) = 0.508 W/kg
SAR(1 g) = 0.322 W/kg; SAR(10 g) = 0.213 W/kg
Maximum value of SAR (measured) = 0.373 W/kg




               0 dB = 0.373 W/kg = -4.28 dBW/kg


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab   Date: 2019/6/7

#46_LTE Band 13_10M_QPSK_1_0_Front_10mm_Ch23230


Communication System: LTE; Frequency: 782 MHz;Duty Cycle: 1:1
Medium: HSL_750_190607 Medium parameters used: f = 782 MHz; σ = 0.921 S/m; εr = 42.547; ρ
= 1000 kg/m3
                    23.4                      22.4

DASY5 Configuration:
- Probe: ES3DV3 - SN3124; ConvF(6.15, 6.15, 6.15) @ 782 MHz; Calibrated: 2019/1/15
- Sensor-Surface: 3mm (Mechanical Surface Detection)
- Electronics: DAE4 Sn316; Calibrated: 2019/1/3
- Phantom: SAM_Left; Type: QD000P40CD; Serial: TP:1431
- Measurement SW: DASY52, Version 52.10 (2);SEMCAD X Version 14.6.12 (7450)


Area Scan (61x71x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm
Maximum value of SAR (interpolated) = 0.487 W/kg

Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value = 17.21 V/m; Power Drift = 0.08 dB
Peak SAR (extrapolated) = 0.674 W/kg
SAR(1 g) = 0.420 W/kg; SAR(10 g) = 0.278 W/kg
Maximum value of SAR (measured) = 0.490 W/kg




               0 dB = 0.490 W/kg = -3.10 dBW/kg


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab   Date: 2019/6/6

#47_LTE Band 25_20M_QPSK_1_0_Back_10mm_Ch26590


Communication System: LTE; Frequency: 1905 MHz;Duty Cycle: 1:1
Medium: HSL_1900_190606 Medium parameters used: f = 1905 MHz; σ = 1.464 S/m; εr = 38.988;
ρ = 1000 kg/m3
                    23.6                      22.6

DASY5 Configuration:
- Probe: ES3DV3 - SN3124; ConvF(4.95, 4.95, 4.95) @ 1905 MHz; Calibrated: 2019/1/15
- Sensor-Surface: 3mm (Mechanical Surface Detection)
- Electronics: DAE4 Sn316; Calibrated: 2019/1/3
- Phantom: SAM-Middle; Type: SAM; Serial: 1796
- Measurement SW: DASY52, Version 52.10 (2);SEMCAD X Version 14.6.12 (7450)


Area Scan (61x71x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm.
Maximum value of SAR (interpolated) = 1.03 W/kg

Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value = 25.63 V/m; Power Drift = -0.01 dB
Peak SAR (extrapolated) = 1.34 W/kg
SAR(1 g) = 0.825 W/kg; SAR(10 g) = 0.501 W/kg
Maximum value of SAR (measured) = 0.937 W/kg




               0 dB = 0.937 W/kg = -0.28 dBW/kg


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab   Date: 2019/4/30


#48_LTE Band 26_15M_QPSK_1_74_Back_10mm_Ch26865


Communication System: LTE; Frequency: 831.5 MHz;Duty Cycle: 1:1
Medium: HSL_850_190430 Medium parameters used: £ = 831.5 MHz; 0 = 0.874 S/m; & = 41.117; p = 1000
kg/m3
Ambient Temperature : 23.2 °C ; Liquid Temperature : 22.2 °C

DASYS5 Configuration:
— Probe: EX3DV4 — SN3931; ConvF(10.07, 10.07, 10.07) @ 831.5 MHz; Calibrated: 2018/9/27
— Sensor—Surface: 1.4mm (Mechanical Surface Detection)
— Electronics: DAFEA4 Sn1399; Calibrated: 2018/11/16
— Phantom: SAM_Left; Type: QDO0O0P40CD; Serial: TP:1682
— Measurement SW: DASY52, Version 52.10 (2),SEMCAD X Version 14.6.12 (7450)


Area Scan (61x121x1):; Interpolated grid: dx=1.500 mm, dy=1.500 mm
Maximum value of SAR (interpolated) = 0.804 W/kg

Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value = 32.76 V/m; Power Drift = —0.06 dB
Peak SAR (extrapolated) = 1.08 W/kg
SAR(I g) = 0.552 W/kg; SAR(10 g) = 0.297 W/kg
Maximum value of SAR (measured) = 0.847 W/kg

        dB
        0


        —3.00


        —6.00


        —8.99


        —11.99


        —14.99
                    0 dB = 0.847 W/kg = —0.72 dBW/kg


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab   Date: 2019/5/2

#49_LTE Band 66_20M_QPSK_1_0_Back_10mm_Ch132322


Communication System: LTE ; Frequency: 1745 MHz;Duty Cycle: 1:1
Medium: HSL_1750_190502 Medium parameters used : f = 1745 MHz; σ = 1.368 S/m; εr = 41.789;
ρ = 1000 kg/m3
                    23.6                      22.6

DASY5 Configuration:
- Probe: ES3DV3 - SN3169; ConvF(5.48, 5.48, 5.48) @ 1745 MHz; Calibrated: 2018/5/28
- Sensor-Surface: 3mm (Mechanical Surface Detection)
- Electronics: DAE4 Sn918; Calibrated: 2018/6/20
- Phantom: SAM_Left; Type: QD000P40CD; Serial: TP:1431
- Measurement SW: DASY52, Version 52.10 (2);SEMCAD X Version 14.6.12 (7450)


Area Scan (71x121x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm
Maximum value of SAR (interpolated) = 0.838 W/kg

Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value = 22.66 V/m; Power Drift = -0.03 dB
Peak SAR (extrapolated) = 1.21 W/kg
SAR(1 g) = 0.719 W/kg; SAR(10 g) = 0.438 W/kg
Maximum value of SAR (measured) = 0.864 W/kg




               0 dB = 0.864 W/kg = -0.63 dBW/kg


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab   Date: 2019/5/1


#50_LTE Band 71_20M_QPSK_1_0_Back_10mm_Ch133297


Communication System: LTE; Frequency : 680.5 MHz;Duty Cycle: 1:1
Medium: HSL_750_190501 Medium parameters used: £ = 680.5 MHz; 0 = 0.857 S/m; &, = 41.734; p = 1000
kg/m3
Ambient Temperature : 23.5 °C ; Liquid Temperature : 22.5 °C

DASYS5 Configuration:
— Probe: EX3DV4 — SN3931; ConvF(10.54, 10.54, 10.54) @ 680.5 MHz; Calibrated: 2018/9/27
— Sensor—Surface: 1.4mm (Mechanical Surface Detection)
— Electronics: DAFEA4 Sn1399; Calibrated: 2018/11/16
— Phantom: SAM_Left; Type: QDO0O0P40CD; Serial: TP:1682
— Measurement SW: DASY52, Version 52.10 (2),SEMCAD X Version 14.6.12 (7450)


Area Scan (61x121x1):; Interpolated grid: dx=1.500 mm, dy=1.500 mm
Maximum value of SAR (interpolated) = 0.419 W/kg

Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value =21.67 V/m; Power Drift = —0.08 dB
Peak SAR (extrapolated) =0.483 W/kg
SAR(I g) = 0.298 W/kg; SAR(10 g) = 0.202 W/kg
Maximum value of SAR (measured) = 0.403 W/kg

        dB
        0


        —2.64


        —5.29


        —£.93


        —10.58


        —13.22
                    0 dB = 0.403 W/kg = —3.95 dBW/kg


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab   Date: 2019/6/20

#51_LTE Band 41_20M_QPSK_1_0_Back_10mm_Ch39750


Communication System: LTE; Frequency: 2506 MHz;Duty Cycle: 1:1.59
Medium: HSL_2600_190620 Medium parameters used: f = 2506 MHz; σ = 1.86 S/m; εr = 38.508; ρ
= 1000 kg/m3
                    23.3                      22.3

DASY5 Configuration:
- Probe: ES3DV3 - SN3270; ConvF(4.43, 4.43, 4.43) @ 2506 MHz; Calibrated: 2018/9/24
- Sensor-Surface: 3mm (Mechanical Surface Detection)
- Electronics: DAE3 Sn577; Calibrated: 2018/9/19
- Phantom: SAM-Right; Type: SAM; Serial: TP-1503
- Measurement SW: DASY52, Version 52.10 (2);SEMCAD X Version 14.6.12 (7470)


Area Scan (91x81x1): Interpolated grid: dx=1.200 mm, dy=1.200 mm
Maximum value of SAR (interpolated) = 1.05 W/kg

Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm
Reference Value = 16.50 V/m; Power Drift = -0.15 dB
Peak SAR (extrapolated) = 1.73 W/kg
SAR(1 g) = 0.812 W/kg; SAR(10 g) = 0.358 W/kg
Maximum value of SAR (measured) = 1.08 W/kg




               0 dB = 1.08 W/kg = 0.33 dBW/kg


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab   Date: 2019/7/1

#52_WLAN2.4GHz_802.11b 1Mbps_Back_10mm_Ch1;Ant 3


Communication System: 802.11b; Frequency: 2412 MHz;Duty Cycle: 1:1.007
Medium: HSL_2450_190701 Medium parameters used : f = 2412 MHz; σ = 1.748 S/m; εr = 40.06;
ρ = 1000 kg/m3
Ambient Temperature:23.8 ℃; Liquid Temperature:22.8 ℃

DASY5 Configuration
- Probe: EX3DV4 - SN7515;ConvF(7.42, 7.42, 7.42) @ 2412 MHz;Calibrated: 2018/10/3
- Sensor-Surface: 1.4mm (Mechanical Surface Detection)
- Electronics: DAE3 Sn360; Calibrated: 2018/10/29
- Phantom: Twin-SAM V5.0 (30deg probe tilt); Type: QD 000 P40 CD; Serial: 1885
- Measurement SW: DASY52, Version 52.10 (2); SEMCAD X Version 14.6.12 (7450)


Area Scan (81x91x1): Interpolated grid: dx=1.200 mm, dy=1.200 mm
Maximum value of SAR (interpolated) = 1.77 W/kg

Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm
Reference Value = 17.22 V/m; Power Drift = -0.15 dB
Peak SAR (extrapolated) = 2.19 W/kg
SAR(1 g) = 1.01 W/kg; SAR(10 g) = 0.477 W/kg
Maximum value of SAR (measured) = 1.76 W/kg




               0 dB = 1.76 W/kg = 2.46 dBW/kg


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab   Date: 2019/6/27

#53_WLAN5GHz_802.11n-HT40 MCS0_Back_10mm_Ch54;Ant 2


Communication System: 802.11n ; Frequency: 5270 MHz;Duty Cycle: 1:1.032
Medium: HSL_5G_190627 Medium parameters used: f = 5270 MHz; σ = 4.618 S/m; εr = 35.936; ρ
= 1000 kg/m3
Ambient Temperature:23.6 ℃; Liquid Temperature:22.6 ℃

DASY5 Configuration
- Probe: EX3DV4 - SN7515;ConvF(5.45, 5.45, 5.45) @ 5270 MHz;Calibrated: 2018/10/3
- Sensor-Surface: 1.4mm (Mechanical Surface Detection)
- Electronics: DAE3 Sn360; Calibrated: 2018/10/29
- Phantom: Twin-SAM V5.0 (30deg probe tilt); Type: QD 000 P40 CD; Serial: 1885
- Measurement SW: DASY52, Version 52.10 (2); SEMCAD X Version 14.6.12 (7450)


Area Scan (121x101x1): Interpolated grid: dx=1.000 mm, dy=1.000 mm
Maximum value of SAR (interpolated) = 0.997 W/kg

Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=4mm, dy=4mm, dz=1.4mm
Reference Value = 7.663 V/m; Power Drift = 0.12 dB
Peak SAR (extrapolated) = 1.66 W/kg
SAR(1 g) = 0.452 W/kg; SAR(10 g) = 0.173 W/kg
Maximum value of SAR (measured) = 1.02 W/kg




               0 dB = 1.02 W/kg = 0.09 dBW/kg


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab   Date: 2019/6/27

#54_WLAN5GHz_802.11ac-VHT80 MCS0_Back_10mm_Ch138;Ant 5


Communication System: 802.11ac ; Frequency: 5690 MHz;Duty Cycle: 1:1.075
Medium: HSL_5G_190627 Medium parameters used : f = 5690 MHz; σ = 5.043 S/m; εr = 35.383; ρ
= 1000 kg/m3
Ambient Temperature:23.6 ℃; Liquid Temperature:22.6 ℃

DASY5 Configuration
- Probe: EX3DV4 - SN7515;ConvF(4.95, 4.95, 4.95) @ 5690 MHz;Calibrated: 2018/10/3
- Sensor-Surface: 1.4mm (Mechanical Surface Detection)
- Electronics: DAE3 Sn360; Calibrated: 2018/10/29
- Phantom: Twin-SAM V5.0 (30deg probe tilt); Type: QD 000 P40 CD; Serial: 1885
- Measurement SW: DASY52, Version 52.10 (2); SEMCAD X Version 14.6.12 (7450)


Area Scan (121x101x1): Interpolated grid: dx=1.000 mm, dy=1.000 mm
Maximum value of SAR (interpolated) = 0.594 W/kg

Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=4mm, dy=4mm, dz=1.4mm
Reference Value = 9.104 V/m; Power Drift = -0.05 dB
Peak SAR (extrapolated) = 1.67 W/kg
SAR(1 g) = 0.522 W/kg; SAR(10 g) = 0.210 W/kg
Maximum value of SAR (measured) = 1.129 W/kg




               0 dB = 1.129 W/kg = 0.53 dBW/kg


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab   Date: 2019/6/27

#55_WLAN5GHz_802.11ac-VHT80 MCS0_Back_10mm_Ch155;Ant 5


Communication System: 802.11ac ; Frequency: 5775 MHz;Duty Cycle: 1:1.075
Medium: HSL_5G_190627 Medium parameters used: f = 5775 MHz; σ = 5.137 S/m; εr = 35.236; ρ
= 1000 kg/m3
Ambient Temperature:23.6 ℃; Liquid Temperature:22.6 ℃

DASY5 Configuration
- Probe: EX3DV4 - SN7515;ConvF(4.95, 4.95, 4.95) @ 5775 MHz;Calibrated: 2018/10/3
- Sensor-Surface: 1.4mm (Mechanical Surface Detection)
- Electronics: DAE3 Sn360; Calibrated: 2018/10/29
- Phantom: Twin-SAM V5.0 (30deg probe tilt); Type: QD 000 P40 CD; Serial: 1885
- Measurement SW: DASY52, Version 52.10 (2); SEMCAD X Version 14.6.12 (7450)


Area Scan (61x51x1): Interpolated grid: dx=2.000 mm, dy=2.000 mm
Maximum value of SAR (interpolated) = 0.762 W/kg

Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=4mm, dy=4mm, dz=1.4mm
Reference Value = 6.956 V/m; Power Drift = -0.09 dB
Peak SAR (extrapolated) = 1.11 W/kg
SAR(1 g) = 0.411 W/kg; SAR(10 g) = 0.175 W/kg
Maximum value of SAR (measured) = 0.724 W/kg




               0 dB = 0.724 W/kg = -1.4 dBW/kg


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab   Date: 2019/7/1

#56_Bluethooth_1Mbps_Back_10mm_Ch0;Ant 2


Communication System: Bluetooth ; Frequency: 2402 MHz;Duty Cycle: 1:1.301
Medium: HSL_2450_190701 Medium parameters used : f = 2402 MHz; σ = 1.738 S/m; εr = 40.088;
ρ = 1000 kg/m3
Ambient Temperature:23.8 ℃; Liquid Temperature:22.8 ℃

DASY5 Configuration
- Probe: EX3DV4 - SN7515;ConvF(7.42, 7.42, 7.42) @ 2402 MHz;Calibrated: 2018/10/3
- Sensor-Surface: 1.4mm (Mechanical Surface Detection)
- Electronics: DAE3 Sn360; Calibrated: 2018/10/29
- Phantom: Twin-SAM V5.0 (30deg probe tilt); Type: QD 000 P40 CD; Serial: 1885
- Measurement SW: DASY52, Version 52.10 (2); SEMCAD X Version 14.6.12 (7450)


Area Scan (81x91x1): Interpolated grid: dx=1.200 mm, dy=1.200 mm
Maximum value of SAR (interpolated) = 0.226 W/kg

Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm
Reference Value = 7.912 V/m; Power Drift = 0.01 dB
Peak SAR (extrapolated) = 0.285 W/kg
SAR(1 g) = 0.139 W/kg; SAR(10 g) = 0.070 W/kg
Maximum value of SAR (measured) = 0.228 W/kg




               0 dB = 0.228 W/kg = -6.42 dBW/kg