RF Exposure Info._20190714_v1 - A4RG020MN_TestRpt_RFExp_Appendix B-1

FCC ID: A4RG020MN

RF Exposure Info

Download: PDF
FCCID_4414655

Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab   Date: 2019/6/17

#01_GSM850_GPRS (4 Tx slots)_Right Cheek_Ch251


Communication System: GSM850; Frequency: 848.8 MHz;Duty Cycle: 1:2.08
Medium: HSL_850_190617 Medium parameters used: f = 849 MHz; σ = 0.885 S/m; εr = 41.046; ρ
= 1000 kg/m3
                    23.6                      22.6

DASY5 Configuration:
- Probe: ES3DV3 - SN3124; ConvF(5.97, 5.97, 5.97) @ 848.8 MHz; Calibrated: 2019/1/15
- Sensor-Surface: 3mm (Mechanical Surface Detection)
- Electronics: DAE4 Sn316; Calibrated: 2019/1/3
- Phantom: SAM_Left; Type: QD000P40CD; Serial: TP:1431
- Measurement SW: DASY52, Version 52.10 (2);SEMCAD X Version 14.6.12 (7470)


Area Scan (71x81x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm
Maximum value of SAR (interpolated) = 0.966 W/kg

Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value = 4.098 V/m; Power Drift = 0.11 dB
Peak SAR (extrapolated) = 1.94 W/kg
SAR(1 g) = 0.843 W/kg; SAR(10 g) = 0.471 W/kg
Maximum value of SAR (measured) = 1.11 W/kg




               0 dB = 1.11 W/kg = 0.45 dBW/kg


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab   Date: 2019/6/18

#02_GSM1900_GPRS (4 Tx slots)_Right Tilted_Ch810


Communication System: PCS; Frequency: 1909.8 MHz;Duty Cycle: 1:2.08
Medium: HSL_1900_190618 Medium parameters used: f = 1910 MHz; σ = 1.432 S/m; εr = 41.09; ρ
= 1000 kg/m3
                    23.8                      22.8

DASY5 Configuration:
- Probe: ES3DV3 - SN3270; ConvF(5.17, 5.17, 5.17) @ 1909.8 MHz; Calibrated: 2018/9/24
- Sensor-Surface: 3mm (Mechanical Surface Detection)
- Electronics: DAE3 Sn577; Calibrated: 2018/9/19
- Phantom: SAM-Middle; Type: SAM; Serial: 1796
- Measurement SW: DASY52, Version 52.10 (2);SEMCAD X Version 14.6.12 (7470)


Area Scan (71x81x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm
Maximum value of SAR (interpolated) = 0.861 W/kg

Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value = 17.28 V/m; Power Drift = 0.11 dB
Peak SAR (extrapolated) = 1.59 W/kg
SAR(1 g) = 0.747 W/kg; SAR(10 g) = 0.329 W/kg
Maximum value of SAR (measured) = 1.03 W/kg




               0 dB = 1.03 W/kg = 0.13 dBW/kg


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab   Date: 2019/6/18

#03_WCDMA II_RMC 12.2Kbps_Right Tilted_Ch9538


Communication System: WCDMA; Frequency: 1907.6 MHz;Duty Cycle: 1:1
Medium: HSL_1900_190618 Medium parameters used: f = 1908 MHz; σ = 1.43 S/m; εr = 41.101; ρ
= 1000 kg/m3
                    23.8                    22.8

DASY5 Configuration:
- Probe: ES3DV3 - SN3270; ConvF(5.17, 5.17, 5.17) @ 1907.6 MHz; Calibrated: 2018/9/24
- Sensor-Surface: 3mm (Mechanical Surface Detection)
- Electronics: DAE3 Sn577; Calibrated: 2018/9/19
- Phantom: SAM-Middle; Type: SAM; Serial: 1796
- Measurement SW: DASY52, Version 52.10 (2);SEMCAD X Version 14.6.12 (7470)


Area Scan (71x81x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm
Maximum value of SAR (interpolated) = 0.944 W/kg

Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value = 18.58 V/m; Power Drift = 0.15 dB
Peak SAR (extrapolated) = 1.78 W/kg
SAR(1 g) = 0.823 W/kg; SAR(10 g) = 0.363 W/kg
Maximum value of SAR (measured) = 1.16 W/kg




               0 dB = 1.16 W/kg = 0.64 dBW/kg


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab   Date: 2019/6/18

#04_WCDMA IV_RMC 12.2Kbps_Right Tilted_Ch1513


Communication System: WCDMA; Frequency: 1752.6 MHz;Duty Cycle: 1:1
Medium: HSL_1750_190618 Medium parameters used: f = 1753 MHz; σ = 1.357 S/m; εr = 39.916;
ρ = 1000 kg/m3
                    23.8                    22.8

DASY5 Configuration:
- Probe: ES3DV3 - SN3124; ConvF(5.18, 5.18, 5.18) @ 1752.6 MHz; Calibrated: 2019/1/15
- Sensor-Surface: 3mm (Mechanical Surface Detection)
- Electronics: DAE4 Sn316; Calibrated: 2019/1/3
- Phantom: SAM-Middle; Type: SAM; Serial: 1796
- Measurement SW: DASY52, Version 52.10 (2);SEMCAD X Version 14.6.12 (7470)


Area Scan (71x81x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm
Maximum value of SAR (interpolated) = 0.901 W/kg

Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value = 18.11 V/m; Power Drift = 0.15 dB
Peak SAR (extrapolated) = 1.53 W/kg
SAR(1 g) = 0.809 W/kg; SAR(10 g) = 0.359 W/kg
Maximum value of SAR (measured) = 1.06 W/kg




               0 dB = 1.06 W/kg = 0.25 dBW/kg


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab   Date: 2019/6/17

#05_WCDMA V_RMC 12.2Kbps_Right Cheek_Ch4233


Communication System: WCDMA; Frequency: 846.6 MHz;Duty Cycle: 1:1
Medium: HSL_850_190617 Medium parameters used: f = 847 MHz; σ = 0.883 S/m; εr = 41.067; ρ
= 1000 kg/m3
                    23.6                     22.6

DASY5 Configuration:
- Probe: ES3DV3 - SN3124; ConvF(5.97, 5.97, 5.97) @ 846.6 MHz; Calibrated: 2019/1/15
- Sensor-Surface: 3mm (Mechanical Surface Detection)
- Electronics: DAE4 Sn316; Calibrated: 2019/1/3
- Phantom: SAM_Left; Type: QD000P40CD; Serial: TP:1431
- Measurement SW: DASY52, Version 52.10 (2);SEMCAD X Version 14.6.12 (7470)


Area Scan (71x81x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm
Maximum value of SAR (interpolated) = 0.862 W/kg

Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value = 29.21 V/m; Power Drift = -0.07 dB
Peak SAR (extrapolated) = 1.62 W/kg
SAR(1 g) = 0.763 W/kg; SAR(10 g) = 0.406 W/kg
Maximum value of SAR (measured) = 0.944 W/kg




               0 dB = 0.944 W/kg = -0.25 dBW/kg


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab   Date: 2019/5/5

#06_LTE Band 4_20M_QPSK_1_0_Left Cheek_Ch20175


Communication System: LTE; Frequency: 1732.5 MHz;Duty Cycle: 1:1
Medium: HSL_1750_190505 Medium parameters used: f = 1733 MHz; σ = 1.351 S/m; εr = 39.76; ρ
= 1000 kg/m3
                    23.1                      22.1

DASY5 Configuration:
- Probe: ES3DV3 - SN3169; ConvF(5.48, 5.48, 5.48) @ 1732.5 MHz; Calibrated: 2018/5/28
- Sensor-Surface: 3mm (Mechanical Surface Detection)
- Electronics: DAE3 Sn577; Calibrated: 2018/9/19
- Phantom: SAM_Left; Type: QD000P40CD; Serial: TP:1431
- Measurement SW: DASY52, Version 52.10 (2);SEMCAD X Version 14.6.12 (7450)


Area Scan (61x121x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm
Maximum value of SAR (interpolated) = 0.557 W/kg

Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value = 20.00 V/m; Power Drift = -0.07 dB
Peak SAR (extrapolated) = 0.723 W/kg
SAR(1 g) = 0.486 W/kg; SAR(10 g) = 0.313 W/kg
Maximum value of SAR (measured) = 0.558 W/kg




               0 dB = 0.558 W/kg = -2.53 dBW/kg


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab   Date: 2019/6/19

#07_LTE Band 7_20M_QPSK_1_99_Left Cheek_Ch21350


Communication System: LTE; Frequency: 2560 MHz;Duty Cycle: 1:1
Medium: HSL_2600_190619 Medium parameters used: f = 2560 MHz; σ = 1.913 S/m; εr = 39.101;
ρ = 1000 kg/m3
                    23.5                      22.5

DASY5 Configuration:
- Probe: ES3DV3 - SN3270; ConvF(4.43, 4.43, 4.43) @ 2560 MHz; Calibrated: 2018/9/24
- Sensor-Surface: 3mm (Mechanical Surface Detection)
- Electronics: DAE3 Sn577; Calibrated: 2018/9/19
- Phantom: SAM-Right; Type: SAM; Serial: TP-1503
- Measurement SW: DASY52, Version 52.10 (2);SEMCAD X Version 14.6.12 (7470)


Area Scan (91x141x1): Interpolated grid: dx=1.200 mm, dy=1.200 mm
Maximum value of SAR (interpolated) = 1.09 W/kg

Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm
Reference Value = 19.74 V/m; Power Drift = 0.07 dB
Peak SAR (extrapolated) = 1.51 W/kg
SAR(1 g) = 0.833 W/kg; SAR(10 g) = 0.433 W/kg
Maximum value of SAR (measured) = 1.05 W/kg




               0 dB = 1.05 W/kg = 0.21 dBW/kg


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab   Date: 2019/6/17

#08_LTE Band 12_10M_QPSK_50_0_Right Cheek_Ch23095


Communication System: LTE; Frequency: 707.5 MHz;Duty Cycle: 1:1
Medium: HSL_750_190617 Medium parameters used : f = 707.5 MHz; σ = 0.85 S/m; εr = 41.112; ρ
= 1000 kg/m3
                    23.6                      22.6

DASY5 Configuration:
- Probe: ES3DV3 - SN3124; ConvF(6.15, 6.15, 6.15) @ 707.5 MHz; Calibrated: 2019/1/15
- Sensor-Surface: 3mm (Mechanical Surface Detection)
- Electronics: DAE4 Sn316; Calibrated: 2019/1/3
- Phantom: SAM_Left; Type: QD000P40CD; Serial: TP:1431
- Measurement SW: DASY52, Version 52.10 (2);SEMCAD X Version 14.6.12 (7470)


Area Scan (71x81x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm
Maximum value of SAR (interpolated) = 0.974 W/kg

Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value = 31.90 V/m; Power Drift = -0.04 dB
Peak SAR (extrapolated) = 1.98 W/kg
SAR(1 g) = 0.851 W/kg; SAR(10 g) = 0.490 W/kg
Maximum value of SAR (measured) = 1.06 W/kg




               0 dB = 1.06 W/kg = 0.25 dBW/kg


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab   Date: 2019/6/17

#09_LTE Band 13_10M_QPSK_25_12_Right Cheek_Ch23230


Communication System: LTE; Frequency: 782 MHz;Duty Cycle: 1:1
Medium: HSL_750_190617 Medium parameters used: f = 782 MHz; σ = 0.919 S/m; εr = 40.155; ρ
= 1000 kg/m3
                    23.6                      22.6

DASY5 Configuration:
- Probe: ES3DV3 - SN3124; ConvF(6.15, 6.15, 6.15) @ 782 MHz; Calibrated: 2019/1/15
- Sensor-Surface: 3mm (Mechanical Surface Detection)
- Electronics: DAE4 Sn316; Calibrated: 2019/1/3
- Phantom: SAM_Left; Type: QD000P40CD; Serial: TP:1431
- Measurement SW: DASY52, Version 52.10 (2);SEMCAD X Version 14.6.12 (7470)


Area Scan (71x81x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm
Maximum value of SAR (interpolated) = 1.09 W/kg

Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value = 32.48 V/m; Power Drift = -0.08 dB
Peak SAR (extrapolated) = 2.07 W/kg
SAR(1 g) = 0.897 W/kg; SAR(10 g) = 0.523 W/kg
Maximum value of SAR (measured) = 1.17 W/kg




               0 dB = 1.17 W/kg = 0.68 dBW/kg


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab   Date: 2019/6/18

#10_LTE Band 25_20M_QPSK_50_24_Right Tilted_Ch26590


Communication System: LTE; Frequency: 1905 MHz;Duty Cycle: 1:1
Medium: HSL_1900_190618 Medium parameters used : f = 1905 MHz; σ = 1.426 S/m; εr = 41.118;
ρ = 1000 kg/m3
                    23.8                      22.8

DASY5 Configuration:
- Probe: ES3DV3 - SN3270; ConvF(5.17, 5.17, 5.17) @ 1905 MHz; Calibrated: 2018/9/24
- Sensor-Surface: 3mm (Mechanical Surface Detection)
- Electronics: DAE3 Sn577; Calibrated: 2018/9/19
- Phantom: SAM-Middle; Type: SAM; Serial: 1796
- Measurement SW: DASY52, Version 52.10 (2);SEMCAD X Version 14.6.12 (7470)


Area Scan (71x81x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm
Maximum value of SAR (interpolated) = 1.02 W/kg

Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value = 20.48 V/m; Power Drift = 0.05 dB
Peak SAR (extrapolated) = 1.93 W/kg
SAR(1 g) = 0.901 W/kg; SAR(10 g) = 0.401 W/kg
Maximum value of SAR (measured) = 1.25 W/kg




               0 dB = 1.25 W/kg = 0.97 dBW/kg


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab   Date: 2019/6/17

#11_LTE Band 26_15M_QPSK_75_0_Right Cheek_Ch26865


Communication System: LTE; Frequency: 831.5 MHz;Duty Cycle: 1:1
Medium: HSL_850_190617 Medium parameters used : f = 831.5 MHz; σ = 0.868 S/m; εr = 41.268;
ρ = 1000 kg/m3
                    23.6                      22.6

DASY5 Configuration:
- Probe: ES3DV3 - SN3124; ConvF(5.97, 5.97, 5.97) @ 831.5 MHz; Calibrated: 2019/1/15
- Sensor-Surface: 3mm (Mechanical Surface Detection)
- Electronics: DAE4 Sn316; Calibrated: 2019/1/3
- Phantom: SAM_Left; Type: QD000P40CD; Serial: TP:1431
- Measurement SW: DASY52, Version 52.10 (2);SEMCAD X Version 14.6.12 (7470)


Area Scan (71x81x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm
Maximum value of SAR (interpolated) = 1.11 W/kg

Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value = 33.48 V/m; Power Drift = -0.06 dB
Peak SAR (extrapolated) = 2.17 W/kg
SAR(1 g) = 0.924 W/kg; SAR(10 g) = 0.524 W/kg
Maximum value of SAR (measured) = 1.25 W/kg




               0 dB = 1.25 W/kg = 0.97 dBW/kg


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab   Date: 2019/6/18

#12_LTE Band 66_20M_QPSK_100_0_Right Tilted_Ch132572


Communication System: LTE; Frequency: 1770 MHz;Duty Cycle: 1:1
Medium: HSL_1750_190618 Medium parameters used: f = 1770 MHz; σ = 1.365 S/m; εr = 39.873;
ρ = 1000 kg/m3
                    23.8                      22.8

DASY5 Configuration:
- Probe: ES3DV3 - SN3124; ConvF(5.18, 5.18, 5.18) @ 1770 MHz; Calibrated: 2019/1/15
- Sensor-Surface: 3mm (Mechanical Surface Detection)
- Electronics: DAE4 Sn316; Calibrated: 2019/1/3
- Phantom: SAM-Middle; Type: SAM; Serial: 1796
- Measurement SW: DASY52, Version 52.10 (2);SEMCAD X Version 14.6.12 (7470)


Area Scan (71x81x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm
Maximum value of SAR (interpolated) = 0.962 W/kg

Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value = 22.42 V/m; Power Drift = -0.06 dB
Peak SAR (extrapolated) = 1.75 W/kg
SAR(1 g) = 0.871 W/kg; SAR(10 g) = 0.407 W/kg
Maximum value of SAR (measured) = 1.18 W/kg




               0 dB = 1.18 W/kg = 0.72 dBW/kg


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab   Date: 2019/6/7

#13_LTE Band 71_20M_QPSK_1_0_Right Cheek_Ch133297


Communication System: LTE; Frequency: 680.5 MHz;Duty Cycle: 1:1
Medium: HSL_750_190607 Medium parameters used: f = 680.5 MHz; σ = 0.857 S/m; εr = 41.744;
ρ = 1000 kg/m3
                    23.4                      22.4

DASY5 Configuration:
- Probe: ES3DV3 - SN3124; ConvF(6.15, 6.15, 6.15) @ 680.5 MHz; Calibrated: 2019/1/15
- Sensor-Surface: 3mm (Mechanical Surface Detection)
- Electronics: DAE4 Sn316; Calibrated: 2019/1/3
- Phantom: SAM_Left; Type: QD000P40CD; Serial: TP:1431
- Measurement SW: DASY52, Version 52.10 (2);SEMCAD X Version 14.6.12 (7450)


Area Scan (61x71x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm
Maximum value of SAR (interpolated) = 1.16 W/kg

Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value = 33.09 V/m; Power Drift = -0.02 dB
Peak SAR (extrapolated) = 2.12 W/kg
SAR(1 g) = 0.925 W/kg; SAR(10 g) = 0.536 W/kg
Maximum value of SAR (measured) = 1.21 W/kg




               0 dB = 1.21 W/kg = 0.83 dBW/kg


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab   Date: 2019/6/19

#14_LTE Band 41_20M_QPSK_1_0_Right Cheek_Ch39750


Communication System: LTE; Frequency: 2506 MHz;Duty Cycle: 1:1.59
Medium: HSL_2600_190619 Medium parameters used: f = 2506 MHz; σ = 1.856 S/m; εr = 39.28; ρ
= 1000 kg/m3
                    23.5                      22.5

DASY5 Configuration:
- Probe: ES3DV3 - SN3270; ConvF(4.43, 4.43, 4.43) @ 2506 MHz; Calibrated: 2018/9/24
- Sensor-Surface: 3mm (Mechanical Surface Detection)
- Electronics: DAE3 Sn577; Calibrated: 2018/9/19
- Phantom: SAM-Right; Type: SAM; Serial: TP-1503
- Measurement SW: DASY52, Version 52.10 (2);SEMCAD X Version 14.6.12 (7470)


Area Scan (91x81x1): Interpolated grid: dx=1.200 mm, dy=1.200 mm
Maximum value of SAR (interpolated) = 1.22 W/kg

Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm
Reference Value = 16.95 V/m; Power Drift = 0.04 dB
Peak SAR (extrapolated) = 2.09 W/kg
SAR(1 g) = 0.864 W/kg; SAR(10 g) = 0.388 W/kg
Maximum value of SAR (measured) = 1.15 W/kg




               0 dB = 1.15 W/kg = 0.61 dBW/kg


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab   Date: 2019/7/1

#15_WLAN2.4GHz_802.11b 1Mbps_Right Cheek_Ch1;Ant 2+3


Communication System: 802.11b; Frequency: 2412 MHz;Duty Cycle: 1:1.008
Medium: HSL_2450_190701 Medium parameters used : f = 2412 MHz; σ = 1.748 S/m; εr = 40.06;
ρ = 1000 kg/m3
Ambient Temperature:23.8 ℃; Liquid Temperature:22.8 ℃

DASY5 Configuration
- Probe: EX3DV4 - SN7515;ConvF(7.42, 7.42, 7.42) @ 2412 MHz;Calibrated: 2018/10/3
- Sensor-Surface: 1.4mm (Mechanical Surface Detection)
- Electronics: DAE3 Sn360; Calibrated: 2018/10/29
- Phantom: Twin-SAM V5.0 (30deg probe tilt); Type: QD 000 P40 CD; Serial: 1885
- Measurement SW: DASY52, Version 52.10 (2); SEMCAD X Version 14.6.12 (7450)


Area Scan (81x91x1): Interpolated grid: dx=1.200 mm, dy=1.200 mm
Maximum value of SAR (interpolated) = 0.937 W/kg

Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm
Reference Value = 14.29 V/m; Power Drift = -0.18 dB
Peak SAR (extrapolated) = 1.05 W/kg
SAR(1 g) = 0.493 W/kg; SAR(10 g) = 0.237 W/kg
Maximum value of SAR (measured) = 0.785 W/kg

Zoom Scan (7x7x7)/Cube 1: Measurement grid: dx=5mm, dy=5mm, dz=5mm
Reference Value = 14.29 V/m; Power Drift = -0.18 dB
Peak SAR (extrapolated) = 0.258 W/kg
SAR(1 g) = 0.131 W/kg; SAR(10 g) = 0.064 W/kg
Maximum value of SAR (measured) = 0.202 W/kg




               0 dB = 0.202 W/kg = -6.95 dBW/kg


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab   Date: 2019/6/27

#16_WLAN5GHz_802.11ac-VHT80 MCS0_Right Cheek_Ch58;Ant 2+5


Communication System: 802.11ac ; Frequency: 5290 MHz;Duty Cycle: 1:1.085
Medium: HSL_5G_190627 Medium parameters used : f = 5290 MHz; σ = 4.637 S/m; εr = 35.887; ρ
= 1000 kg/m3
Ambient Temperature:23.6 ℃; Liquid Temperature:22.6 ℃

DASY5 Configuration
- Probe: EX3DV4 - SN7515;ConvF(5.45, 5.45, 5.45) @ 5290 MHz;Calibrated: 2018/10/3
- Sensor-Surface: 1.4mm (Mechanical Surface Detection)
- Electronics: DAE3 Sn360; Calibrated: 2018/10/29
- Phantom: Twin-SAM V5.0 (30deg probe tilt); Type: QD 000 P40 CD; Serial: 1885
- Measurement SW: DASY52, Version 52.10 (2); SEMCAD X Version 14.6.12 (7450)


Area Scan (101x101x1): Interpolated grid: dx=1.000 mm, dy=1.000 mm
Maximum value of SAR (interpolated) = 0.957 W/kg

Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=4mm, dy=4mm, dz=1.4mm
Reference Value = 10.84 V/m; Power Drift = -0.09 dB
Peak SAR (extrapolated) = 1.44 W/kg
SAR(1 g) = 0.309 W/kg; SAR(10 g) = 0.115 W/kg
Maximum value of SAR (measured) = 0.892 W/kg




               0 dB = 0.892 W/kg = -0.50 dBW/kg


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab   Date: 2019/6/27

#17_WLAN5GHz_802.11ac-VHT80 MCS0_Right Cheek_Ch122;Ant 2


Communication System: 802.11ac ; Frequency: 5610 MHz;Duty Cycle: 1:1.091
Medium: HSL_5G_190627 Medium parameters used : f = 5610 MHz; σ = 4.951 S/m; εr = 35.447; ρ
= 1000 kg/m3
Ambient Temperature:23.6 ℃; Liquid Temperature:22.6 ℃

DASY5 Configuration
- Probe: EX3DV4 - SN7515;ConvF(4.83, 4.83, 4.83) @ 5610 MHz;Calibrated: 2018/10/3
- Sensor-Surface: 1.4mm (Mechanical Surface Detection)
- Electronics: DAE3 Sn360; Calibrated: 2018/10/29
- Phantom: Twin-SAM V5.0 (30deg probe tilt); Type: QD 000 P40 CD; Serial: 1885
- Measurement SW: DASY52, Version 52.10 (2); SEMCAD X Version 14.6.12 (7450)


Area Scan (101x101x1): Interpolated grid: dx=1.000 mm, dy=1.000 mm
Maximum value of SAR (interpolated) = 0.836 W/kg

Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=4mm, dy=4mm, dz=1.4mm
Reference Value = 8.120 V/m; Power Drift = -0.08 dB
Peak SAR (extrapolated) = 1.81 W/kg
SAR(1 g) = 0.348 W/kg; SAR(10 g) = 0.098 W/kg
Maximum value of SAR (measured) = 1.00 W/kg




               0 dB = 1.00 W/kg = 0.00 dBW/kg


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab   Date: 2019/6/27

#18_WLAN5GHz_802.11ac-VHT80 MCS0_Right Cheek_Ch155;Ant 2


Communication System: 802.11ac ; Frequency: 5775 MHz;Duty Cycle: 1:1.091
Medium: HSL_5G_190627 Medium parameters used: f = 5775 MHz; σ = 5.137 S/m; εr = 35.236; ρ
= 1000 kg/m3
Ambient Temperature:23.6 ℃; Liquid Temperature:22.6 ℃

DASY5 Configuration
- Probe: EX3DV4 - SN7515;ConvF(4.95, 4.95, 4.95) @ 5775 MHz;Calibrated: 2018/10/3
- Sensor-Surface: 1.4mm (Mechanical Surface Detection)
- Electronics: DAE3 Sn360; Calibrated: 2018/10/29
- Phantom: Twin-SAM V5.0 (30deg probe tilt); Type: QD 000 P40 CD; Serial: 1885
- Measurement SW: DASY52, Version 52.10 (2); SEMCAD X Version 14.6.12 (7450)


Area Scan (101x101x1): Interpolated grid: dx=1.000 mm, dy=1.000 mm
Maximum value of SAR (interpolated) = 0.660 W/kg

Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=4mm, dy=4mm, dz=1.4mm
Reference Value = 6.010 V/m; Power Drift = -0.17 dB
Peak SAR (extrapolated) = 1.42 W/kg
SAR(1 g) = 0.261 W/kg; SAR(10 g) = 0.068 W/kg
Maximum value of SAR (measured) = 0.762 W/kg




               0 dB = 0.762 W/kg = -1.18 dBW/kg


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab   Date: 2019/7/1

#19_Bluethooth_1Mbps_Right Cheek_Ch39;Ant 2


Communication System: Bluetooth; Frequency: 2441 MHz;Duty Cycle: 1:1.301
Medium: HSL_2450_190701 Medium parameters used : f = 2441 MHz; σ = 1.778 S/m; εr = 39.952;
ρ = 1000 kg/m3
Ambient Temperature:23.8 ℃; Liquid Temperature:22.8 ℃

DASY5 Configuration
- Probe: EX3DV4 - SN7515;ConvF(7.42, 7.42, 7.42) @ 2441 MHz;Calibrated: 2018/10/3
- Sensor-Surface: 1.4mm (Mechanical Surface Detection)
- Electronics: DAE3 Sn360; Calibrated: 2018/10/29
- Phantom: Twin-SAM V5.0 (30deg probe tilt); Type: QD 000 P40 CD; Serial: 1885
- Measurement SW: DASY52, Version 52.10 (2); SEMCAD X Version 14.6.12 (7450)


Area Scan (81x91x1): Interpolated grid: dx=1.200 mm, dy=1.200 mm
Maximum value of SAR (interpolated) = 0.237 W/kg

Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm
Reference Value = 7.791 V/m; Power Drift = -0.19 dB
Peak SAR (extrapolated) = 0.169 W/kg
SAR(1 g) = 0.079 W/kg; SAR(10 g) = 0.037 W/kg
Maximum value of SAR (measured) = 0.130 W/kg




               0 dB = 0.130 W/kg = -8.86 dBW/kg