REPORT NO: 11U14119-2                                                         DATE: MAY 12, 2012
FCC ID: A4R-W1



10.    MAXIMUM PERMISSIBLE EXPOSURE
FCC RULES

§1.1310 The criteria listed in Table 1 shall be used to evaluate the environmental impact of
human exposure to radio-frequency (RF) radiation as specified in §1.1307(b), except in the case
of portable devices which shall be evaluated according to the provisions of §2.1093 of this
chapter.




                                     Page 62 of 69
COMPLIANCE CERTIFICATION SERVICES (UL CCS)                           FORM NO: CCSUP4701D
47173 BENICIA STREET, FREMONT, CA 94538, USA     TEL: (510) 771-1000    FAX: (510) 661-0888
   This report shall not be reproduced except in full, without the written approval of UL CCS.


REPORT NO: 11U14119-2                                                         DATE: MAY 12, 2012
FCC ID: A4R-W1

IC RULES

IC Safety Code 6, Section 2.2.1 (a) A person other than an RF and microwave exposed worker
shall not be exposed to electromagnetic radiation in a frequency band listed in Column 1 of
Table 5, if the field strength exceeds the value given in Column 2 or 3 of Table 5, when
averaged spatially and over time, or if the power density exceeds the value given in Column 4 of
Table 5, when averaged spatially and over time.




                                     Page 63 of 69
COMPLIANCE CERTIFICATION SERVICES (UL CCS)                           FORM NO: CCSUP4701D
47173 BENICIA STREET, FREMONT, CA 94538, USA     TEL: (510) 771-1000    FAX: (510) 661-0888
   This report shall not be reproduced except in full, without the written approval of UL CCS.


REPORT NO: 11U14119-2                                                            DATE: MAY 12, 2012
FCC ID: A4R-W1

EQUATIONS

Power density is given by:

         S = EIRP / (4 * Pi * D^2)
where
         S = Power density in W/m^2
         EIRP = Equivalent Isotropic Radiated Power in W
         D = Separation distance in m

Power density in units of W/m^2 is converted to units of mWc/m^2 by dividing by 10.

Distance is given by:

         D = SQRT (EIRP / (4 * Pi * S))
where
         D = Separation distance in m
         EIRP = Equivalent Isotropic Radiated Power in W
         S = Power density in W/m^2


For multiple colocated transmitters operating simultaneously in frequency bands where the limit
is identical, the total power density is calculated using the total EIRP obtained by summing the
Power * Gain product (in linear units) of each transmitter.

         Total EIRP = (P1 * G1) + (P2 * G2) + ... + (Pn * Pn)
where
         Px = Power of transmitter x
         Gx = Numeric gain of antenna x


In the table(s) below, Power and Gain are entered in units of dBm and dBi respectively and
conversions to linear forms are used for the calculations.


LIMITS

From FCC §1.1310 Table 1 (B), the maximum value of S = 1.0 mW/cm^2

From IC Safety Code 6, Section 2.2 Table 5 Column 4, S = 10 W/m^2


RESULTS




  Band         Mode      Separation   Output    Antenna    IC Power    FCC Power
                          Distance    Power      Gain       Density     Density
                             (m)      (dBm)      (dBi)     (W/m^2)     (mW/cm^2)
  5 GHz       WLAN           0.20      13.85      6.00          0.19     0.019

                                     Page 64 of 69
COMPLIANCE CERTIFICATION SERVICES (UL CCS)                           FORM NO: CCSUP4701D
47173 BENICIA STREET, FREMONT, CA 94538, USA     TEL: (510) 771-1000    FAX: (510) 661-0888
   This report shall not be reproduced except in full, without the written approval of UL CCS.



Document Created: 2019-10-09 15:55:36
Document Modified: 2019-10-09 15:55:36

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC